Flyer DCA
Flyer DCA
Specifications
Measuring principle: Turbidimetry
Process: Single or double determinations
Reagent block: Heated to 37 °C
Coagulation
Systems
4 measuring cells with magnetic mixer motor
4 reagent positions, one of these with magnetic mixer functions
4 x 4 cuvette incubation positions
Light protection cap: Integrated adapter for Coa DATA tips
(Optional) Yellow tips
New
Cuvette: Micro cuvette
Total volume: 150 – 300 μl
Display: Liquid crystal display, 2 lines with 20 characters each
Control panel: Membrane keypad
a t i o n
Memory: A maximum of 7 test methods can be stored
Gen e r
Conversions: PT(sec) in %, ratio, INR, APTT(sec) in ratio, Fibrinogen(sec) in g/l or mg/dl
Calibration curve: Memory of 9 measuring points per assay
Thrombi-Pette: For pipetting start reagents is included (20-200 μl).
ChipCARD and writer: Optional memory board upon request with test specific data such as lot no,
(Optional) calibration curve, pre-selection for test application for PT, aPTT, TT, Fibrinogen… and others.
Printer: Integrated thermal printer, 26 characters per line
Port: RS 232C
Power supply: 2 voltage settings, 115/230V , 60/50 Hz
Dimensions: 27,3 x 34,7 x 12,5 cm
Weight: 5,3 kg
Dutch Diagnostics
Hekkehorst 3
7207 BS Zutphen
The Netherlands
Your partner in
system concepts.
www.dutch-diagnostics.com C
0017 XC folder DD CS.indd 1 28-10-2010 22:43:02
DCA-1 Open system DCA-2 Open system
1 channel coagulation analyzer for all clotting assays 2 channel coagulation analyzer for all clotting assays
Dutch Diagnostics
Specifications Specifications
1 measuring cell with magnetic mixer motor 2 measuring cells with magnetic mixer motor
1 reagent position 4 reagent positions, one of these with magnetic mixer functions
Light protection cap: Integrated adapter for Coa DATA tips Light protection cap: Integrated adapter for Coa DATA tips
Display: Liquid crystal display, 8 digits Display: Liquid crystal display, 2 lines with 20 characters each
Memory: A maximum of 7 test methods can be stored Memory: A maximum of 7 test methods can be stored
Conversions: PT(sec) in %, ratio, INR, APTT(sec) in ratio, Fibrinogen(sec) in g/l or mg/dl Conversions: PT(sec) in %, ratio, INR, APTT(sec) in ratio, Fibrinogen(sec) in g/l or mg/dl
Calibration curve: Memory of 9 measuring points per assay Calibration curve: Memory of 9 measuring points per assay
Thrombi-Pette: For pipetting start reagents is included (20-200 μl). Thrombi-Pette: For pipetting start reagents is included (20-200 μl).
ChipCARD and writer: Optional memory board upon request with test specific data such as lot no, ChipCARD and writer: Optional memory board upon request with test specific data such as lot no,
(Optional) calibration curve, pre-selection for test application for PT, aPTT, TT, Fibrinogen… and others. (Optional) calibration curve, pre-selection for test application for PT, aPTT, TT, Fibrinogen… and others.
Port: RS 232C Printer: Integrated thermal printer, 26 characters per line
(Optional) External printer Epson P40 Adapter 115V/60Hz or 230V/50Hz Port: RS 232C
Power supply: External adapter Power supply: 2 voltage settings, 115/230V , 60/50 Hz
www.dutch-diagnostics.com
Human and animal care