0% found this document useful (0 votes)
33 views

200 Flow Sensor

The document summarizes an OEM flow sensor called the Type 200 that uses the Karman Vortex principle to measure liquid flow rates between 0.5 and 150 l/min. It has nominal diameters between DN 6-25 and provides accurate measurements below 1% of full scale for flows under 50% and below 2% for higher flows. Optional integrated temperature sensors allow measuring media temperatures from -40 to 125°C.

Uploaded by

Nguyen Van Quan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

200 Flow Sensor

The document summarizes an OEM flow sensor called the Type 200 that uses the Karman Vortex principle to measure liquid flow rates between 0.5 and 150 l/min. It has nominal diameters between DN 6-25 and provides accurate measurements below 1% of full scale for flows under 50% and below 2% for higher flows. Optional integrated temperature sensors allow measuring media temperatures from -40 to 125°C.

Uploaded by

Nguyen Van Quan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Vortex flow sensor

OEM Flow sensor for liquid


media
Type 200

The flow sensor Type 200 is based on the Karman Vortex


principle. You can choose between various versions. The Type
200 is available with or without temperature measurement.
With no moving parts the flow sensor is not sensitive to
debris, has marginal pressure loss and high accuracy.

Flow range + Low cost product with high levels of accuracy

0.5 ... 150 l/min + Temperature non-sensitive measuring principle


+ Excellent media resistance (measuring element not in
contact with the media)
+ Wide application temperature range
Nominal diameters + Marginal loss of pressure
DN 6 / 8 / 10 / 15 / 20 / 25 + Measuring element not sensitive to debris
+ Direct temperature measurement in the medium with
PT1000 or NTC
Temperature measurement + Drinking water approval KTW, W270, ACS, WRAS

-40 ... +125 ºC

Pressure and flow Huba Control Type 200 | Technical data subject to change | Edition 09/2020 1/9
Technical overview
Flow measurement
Measuring principle Vortex Piezoelectric sensor element
Measuring range 0.5 ... 150 l/min
Nominal diameters DN 6 / 8 / 10 / 15 / 20 / 25
Accuracy at < 50% fs (water) < 1% fs
Accuracy at > 50% fs (water) < 2% measuring value
Immediately Signal delay < 100 ms
Response time
Therefore suitable for spigot use. Response time < 5 ms

Temperature measurement (> DN 8)


PT1000
Measuring principle Resistance
NTC
Measuring range -40 ... +125 ºC
PT1000 @ T = 0 ºC ± 0.3 K
Accuracy Class B DIN EN 60751
@ T ≠ 0 ºC ± 0.3 K ± 0.005 * ΔT
Measuring range -40 ... +125 ºC
@ T = +25 ºC ± 0.7 K
NTC NTC 10 kOhm @ 25 ºC @ T < +25 ºC ± 0.7 K ± 0.025 * ΔT
Accuracy
β = 4050 @ T > +25 ºC ± 0.7 K ± 0.050 * ΔT
Self-heating at temperature sensor 1 K/mW
Temperature influences
Conduction resistance to connector 0.8 Ohm

Operating conditions
Suitable for heating circuit water with the usual additives
Medium Other medium on request
Drinking water
Media < +125 ºC
Temperature Ambient -15 ... +85 ºC
Storage -30 ... +85 ºC
(for lifetime) 12 bar at +40 ºC
(for lifetime) 6 bar at +100 ºC
Max pressure and
(for 600 hours) 4 bar at +125 ºC
medium temperature
(for 2 hours) 4 bar at +140 ºC
(max. test pressure) 18 bar at +40 ºC
Cavitation The following equation is valid to prevent cavitation: Pabs_oulet / Pdifference > 5.5

Materials in contact with medium


Sensor paddle ETFE
Case with damming body PA6T/6I (40% GF)
FPM
Sealing material
EPDM (perox.)

Electrical overview
Power supply UIN 5 VDC ±5%
Output flow (Q) Frequency Square pulse signal UOUT_Q_Frequency < 0.1 ... > 4.75 V
ROUT PT1000 PT1000 class B DIN EN 60751
Output temperature (T) Resistant signal ROUT NTC NTC 10 kOhm @ 25 ºC; β = 4050
Connector RAST 2.5 / 2.54 IP 20
Electrical connection and protection class
Connector M12x1 IP 65
Load against GND or IN > 10 kOhm / < 10 nF
standard < 6 mA
Current consumption IIN load free
enhanced EMC protection < 10 mA

Weight
DN 6 / 8 ~ 47 g
DN 10 ~ 57 g
DN 15 ~ 68 g
DN 20 ~ 92 g
DN 25 ~ 100 g

Test / Admissions
Electromagnetic compatibility acc. to EN 61326-2-3 (no protection at surge)
Plastic parts with KTW and W270 approval
Drinking water approval WRAS
ACS

Packaging (multiple packaging) Connection copper tube Outside thread K Outside thread G
DN 6 – Blister 30x Blister 30x
DN 8 / 10 Blister 30x Blister 30x Blister 30x
DN 15 Blister 30x Blister 30x Blister 20x
DN 20 Blister 20x Blister 20x Blister 15x
DN25 – Blister 20x Blister 15x

Minimum life span on high flow rate and high temperature

135
130
125
120
115
110
22 hours
Std
Temperatur in °C
Temperature in ºC

105
10 hours
10 Std
100
95 100 hours
100 Std
90 0.1 year
0.1 Jahr
85 11 year
Jahr
80 10 year
10 Jahre
75
70
65
60
55
50
40 60 80 100 120 140
Flowinin%%
Durchfluss

2/9 Pressure and flow Huba Control Type 200 | Technical data subject to change | Edition 09/2020
Nominal diameters dependent variables

Nominal Quantity per pulse Kf


Tube connection Measuring range Flow rate Frequency range Q0 Pressure drop 1), 2)
diameters @ 50% fs
K
DN 6 0.5 ... 10 l/min 0.386 ml 0.074 ... 1.474 m/s 27 ... 426 Hz -0.14 0.0238 240 * Q2
G

K 0.638 ml 30 ... 384 Hz 0.0398

DN 8 G 0.9 ... 15 l/min 0.631 ml 0.133 ... 2.210 m/s 30 ... 388 Hz -0.3 0.0394 85.00 * Q2

N 0.614 ml 31 ... 399 Hz 0.0383

K 1.399 ml 24 ... 379 Hz 0.0850

DN 10 G 1.8 ... 32 l/min 1.370 ml 0.265 ... 4.716 m/s 24 ... 387 Hz -0.2 0.0832 22.50 * Q2

N 1.384 ml 24 ... 383 Hz 0.0841

K 1.403 ml 26 ... 473 Hz 0.0850

DN 10 G 2.0 ... 40 l/min 1.373 ml 0.295 ... 5.895 m/s 26 ... 483 Hz -0.2 0.0832 22.50 * Q2

N 1.388 ml 26 ... 478 Hz 0.0841

K 3.047 ml 20 ... 272 Hz 0.1843

DN 15 G 3.5 ... 50 l/min 3.016 ml 0.290 ... 4.145 m/s 20 ... 275 Hz -0.2 0.1824 6.70* Q2

N 3.077 ml 20 ... 270 Hz 0.1861

K 6.213 ml 14 ... 227 Hz 0.3754

DN 20 G 5.0 ... 85 l/min 6.125 ml 0.265 ... 4.509 m/s 14 ... 230 Hz -0.3 0.3701 2.50 * Q2

N 6.208 ml 14 ... 227 Hz 0.3751

K 12.412 ml 12 ... 201 Hz 0.7467


DN 25 9.0 ... 150 l/min 0.283 ... 4.709 m/s -0.2 0.92 * Q2
G 12.251 ml 12 ... 204 Hz 0.7370

Characteristic line formula frequency output Legend


QV = Kf * ƒ + Q0 QV Volume flow rate [l/min]
Q0 Axis intercept [l/min]
Kf Coefficient frequency output [(l/min) / ƒ]
Formula quantity per pulse [litres/pulse]
ƒ Frequency [Hz]
quantity Q *K
= V f quantity litres
pulse 60 * (QV - Q0) Quantity per pulse
pulse pulse
(Influence of viscosity for media other than water - see page 8)

1)
incl. 3xDi inlet and outlet side 2)
Pv in Pa; Q in l/min

Pressure and flow Huba Control Type 200 | Technical data subject to change | Edition 09/2020 3/9
1 2 3 4 5 6 7

Order code selection table 200. X X X X X X X


Flow 9
Version Flow and temperature (PT1000) 8 1
Flow and temperature (NTC) 7 1
DN 6 0.5 ... 10 l/min. 9 0 6 1 K,G
DN 8 0.9 ... 15 l/min. 0 8 1
DN 10 1.8 ... 32 l/min. 1 0
Nominal diameters /
DN 10 2.0 ... 40 l/min. 1 1
flow range
DN 15 3.5 ... 50 l/min. 1 5
DN 20 5.0 ... 85 l/min. 2 0
DN 25 9.0 ... 150 l/min. 2 5 K,G
Frequency output, 0 ... 5 VDC (Square pulse signal) 5 VDC standard 9 0
Output / power supply
Frequency output, 0 ... 5 VDC (Square pulse signal) 5 VDC enhanced EMC protection 1
3-pole connector RAST 2.5 9 0
2x3-pole connector RAST 2.5 7,8 1 1
3-pole connector RAST 2.5 (condensation protection) 9 2
Electrical connection
2x3-pole connector RAST 2.5 (condensation protection) 7,8 1 3
3-pole circular connector M12x1 (condensation protection) 9 1 4
5-pole circular connector M12x1 (condensation protection) 7,8 1 5
EPDM Ethylene propylene rubber (peroxidically cross-linked) 1
Sealing material
FPM 1)
Fluoro elastomer 2
connection copper tube (max. DN 20) N
Tube connection Plastic PA6T/6I outside thread K (see dimension diagram) K
outside thread G (see dimension diagram) G

Accessories (supplied loose) Order number


Connection kit DN 8, 10 with copper tube
2)
113775
Connection kit 2) DN 8, 10 with adapter Rp ⅜ Stainless steel 1.4305/AISI 303 113776
Connection kit 2) DN 15 with copper tube 113777
Connection kit 2) DN 15 with adapter Rp ½ Stainless steel 1.4305/AISI 303 113778
Connection kit 2) DN 20 with copper tube 113779
Connection kit 2) DN 20 with adapter Rp ¾ Stainless steel 1.4305/AISI 303 113780
Connector RAST 2.5 with cable 3-pole 30 cm 111668
Connector RAST 2.5 with cable 3-pole 110 cm 101817
Straight-wire box for connector M12x1 with cable 3-pole 200 cm 114605
Corner-wire box for connector M12x1 with cable 3-pole 200 cm 114604
Connector RAST 2.54 with cable 2x3 pole 110 cm (with temperature) 114629
Straight-wire box for connector M12x1 with cable 5-pole 200 cm (with temperature) 114564
Corner-wire box for connector M12x1 with cable 5-pole 200 cm (with temperature) 114563
Straight-wire box for connector M12x1 screwing terminal 5-pole 115024
Clip for DN 8,10 112116
Clip for DN 15 110941
Clip for DN 20 112122
O-Ring for DN 8, DN 10 EPDM ø 13.95 x 2.62 Copper tube and adapter 112124
O-Ring for DN 15 EPDM ø 17.86 x 2.62 Copper tube and adapter 112265
O-Ring for DN 20 EPDM ø 21.89 x 2.62 Copper tube and adapter 112723
O-Ring for DN 25 EPDM ø 31 x 3 (as a replacement, already assembled) 112792
Connection copper tube for DN 8, 10 L=150 mm 112121
Connection copper tube for DN 15 L=150 mm 112211
Connection copper tube for DN 20 L=150 mm 112306
Adapter (inside thread) for DN 8 und DN 10 Rp ⅜ Stainless steel 1.4305/AISI 303 112655
Adapter (inside thread) for DN 15 Rp ½ Stainless steel 1.4305/AISI 303 112660
Adapter (inside thread) for DN 20 Rp ¾ Stainless steel 1.4305/AISI 303 112661

AMP connector 3) Manufacturers order number Colour for flexible wire


3-829868-3 grey 7 x 0.20 mm = 0.22 mm2
12 x 0.20 mm = 0.35 mm2
1-966194-3 beige 7 x 0.25 mm = 0.35 mm2

1)
No drinking water approval 2)
Connection set includes: 2x Clip, 2x Copper tube or Adapter and 2x O-Ring
3)
To order seperately directly from the manufacturer. Find further information in the manufacturers specification no. 114 18049

4/9 Pressure and flow Huba Control Type 200 | Technical data subject to change | Edition 09/2020
Dimension diagram DN 8, 10, 15, 20

1a 5a

2a

3a

4a
1a 2a 3a 4a 5a 6a
DN8 29.5 59.0 32.9 72 30.2 28.9
DN10 32.5 57.3 32.9 77 30.2 28.9
6a
DN15 32.5 62.4 39.0 82 30.2 33.0
DN20 39.3 66.3 43.0 105 30.2 37.4

Dimension diagram DN 6, 8, 10, 15, 20, 25

1d

6d

2d

3d 3d

4d

1d 2d 3d 4d 5d 6d
DN6 K 43.7 53.0 G½ 77 11.5 12
DN6 G 48.2 55.7 G¾ 86 11.5 12
DN8 K 43.7 53.0 G½ 77 11.5 12
DN8 G 48.2 55.7 G¾ 86 11.5 12
5d
DN10 K 35.0 51.3 G½ 81 11.5 19
DN10 G 39.5 54.1 G¾ 90 11.5 19
DN15 K 36.6 56.1 G¾ 87 16 22
DN15 G 41.6 59.5 G1 97 16 22
DN20 K 36.6 61.5 G1 105 20 27
DN20 G 42.6 65.8 G 1¼ 117 20 27
DN25 K 50.0 68.3 G 1¼ 120 26 34
DN25 G 56.0 71.3 G 1½ 132 26 34

Pressure and flow Huba Control Type 200 | Technical data subject to change | Edition 09/2020 5/9
Admissible locking torque

DN6/8/10 DN6/8/10 DN15 DN15 DN20 DN20 DN25 DN25


G½ G¾ G¾ G1 G1 G1 ¼ G1 ¼ G1 ½
Mmin [Nm] 1 1 1 2 2 2.5 2.5 2.5
Mmax [Nm] 12 12 12 12 12 15 15 15

Accessories DN 8, 10, 15, 20


adapter 1.4305 clip
1c
inside thread

2c

3c 7c
o-ring
to adapter 4c

6c 5c 8c

9c

1c 2c 3c 4c 5c 6c 7c 8c 9c
Rp ⅜ DIN 2999
DN8 22 14.0 29 57.65 44.65 24.5 7.3 30.8
lenght min. 9
Rp ⅜ DIN 2999
DN10 22 14.0 29 59.65 47.55 24.5 7.3 30.8
lenght min. 9
Rp ½ DIN 2999
DN15 24 16.4 32 67.05 50.05 28.0 7.6 34.5
length min. 11.5
Rp ¾ DIN 2999
DN20 30 18.5 38 82.25 58.85 28.0 8.7 34.5
lenght min. 13

Geometry of customers connection tube DN 8, 10, 15, 20


clip
o-ring 1b

6b 5b 4b

bevelled edge
min. 0.1
7b
2b

3b 8b

9b

1b 2b 3b 4b 5b 6b 7b 8b 9b
DN8 ø 13.95x2.62 2 ± 0.2 8.9 ± 0.2 ø 13 ± 0.2 ø 15.00 ± 0.08 ø 18.88 ± 0.1 24.5 7.3 30.8
DN10 ø 13.95x2.62 2 ± 0.2 8.9 ± 0.2 ø 13 ±0.2 ø 15.00 ± 0.08 ø 18.88 ± 0.1 24.5 7.3 30.8
DN15 + 0.08
ø 17.86x2.62 2 ± 0.2 8.9 ± 0.3 ø 16 ± 0.2 ø 18.00 ø 21.85 ± 0.1 28.0 7.6 34.5
- 0.06
DN20 + 0.08
ø 21.89x2.62 2 ± 0.2 12.9 ± 0.3 ø 20 ± 0.2 ø 22.00 ø 25.85 ± 0.1 28.0 8.7 34.5
- 0.06

6/9 Pressure and flow Huba Control Type 200 | Technical data subject to change | Edition 09/2020
Tube mounting instructions

Consider the following to ensure the correct function of the sensor.

• Only diameter changes from large to small are allowed.

• Avoid repeated elbows in the same level at entryside

minimum 5xDN
for alternative elbows

minimum 0.5xDN
for recommended 90º elbow
with min. R 1.8xDN

Electrical connections

IN GND
+
IN
OUT Hz 1 4 1 Hz

GND – 3
OUT
GND OUT IN
RAST 2.5 without temperature output Connector M12x1 without temperature output

+
IN
OUT
OUT Hz
GND T2
GND –
GND
T1
Ω
T2 GND IN T1
Connector 2x3-poles with temperature output

IN GND

1 4 2 Hz Pin Colour
5 1 brown
2 3 3 1 blue
OUT 4 black
T2 T1
1 brown
2 white
Ω 3 2 blue
4 black
5 gray
Connector M12x1 with temperature output

Pressure and flow Huba Control Type 200 | Technical data subject to change | Edition 09/2020 7/9
Influence of glycol
With the following definitions we are able to correct the influence of media with higher viscosity than water (= media viscosity > 1.8 cST) in order to reach
a measuring accuracy of 3% fs in the range of 1.8 - 4 cST and of 4% in the range of 4 - 14 cSt (υ = viscosity in cSt).

Definition of viscosity of glycol-water-compound

Kinematic viscosity ethylene glycol water


KinematischeViskositätEthylenglykolͲWasser Kinematic viscosity propylene glycol water
KinematischeViskositätPropylenglykolͲWasser

60 60

0% 0%
50 50
10% 10%
20%
in ºC
Temperaturin°C

Temperaturin°C
40 40 20%
30%

in ºC
Temperature

30%
40%
30 30

Temperature
40%
50%
60% 50%
20 20
70% 60%
10 10

0 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14
viscosity in cSt
ViskositätincSt viscosity in cSt
ViskositätincSt

Definition of respond threshold Qmin Definition of characteristic line formula QV = kf * f + Q0


Minimal detekƟĞrbarer
Minimal detectable flow DurchŇuss Influenceder
EinŇuss on viscocity
ViskositätQ0 auf Q0

25 -12
line formulain l/min
in l/min in l/min

20 -10
DN10 DN10
Q0 in Kennlinienformel

DN15 -8 DN15
flowDurchŇuss

15
DN20 DN20
-6
DN25 DN25
characteristic
Minimaler

10 DN32
DN32 -4
Minimal

5 -2

0 0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 3 4 5 6 7 8 9 10 11 12 13 14

viscosity in cSt
Viskosität in cSt
viscosity in cSt in cSt
Viskosität

Formula respond threshold Qmin in l/min Formula characteristic line for Q > Qmin in l/min
< DN 10 not possible < DN 10 not possible
DN10: Qmin = υ + 0.8 Frequency output:
DN15: Qmin = υ + 2.5 DN10: Q = Kf * f – 0.40υ + 0.20
DN20: Qmin = υ + 4.0 DN15: Q = Kf * f – 0.45υ + 0.25
DN25: Qmin = υ + 8.0 DN20: Q = Kf * f – 0.55υ + 0.25
DN25: Q = Kf * f – 0.80υ + 0.60

8/9 Pressure and flow Huba Control Type 200 | Technical data subject to change | Edition 09/2020
Huba Control AG
Headquarters Schweiz
Industriestrasse 17
CH-5436 Würenlos
Telefon +41 56 436 82 00
Fax +41 56 436 82 82
[email protected]

Huba Control AG Huba Control AG


Niederlassung Deutschland Vestiging Nederland
Schlattgrabenstrasse 24 Hamseweg 20A
D-72141 Walddorfhäslach NL-3828 AD-Hoogland
Telefon +49 7127 2393 00 Telefoon +31 33 433 03 66
Fax +49 7127 2393 20 Telefax +31 33 433 03 77
[email protected] [email protected]

Huba Control SA Huba Control AG


Succursale France Branch Office United Kingdom
Rue Lavoisier Unit 13 Berkshire House, County Park
Technopôle Forbach-Sud Business Centre, Shivenham Road
F-57602 Forbach Cedex Swindon - Wiltshire SN1 2NR
Téléphone +33 3 87 84 73 00 Phone +44 1993 77 66 67
Télécopieur +33 3 87 84 73 01 Fax +44 1993 77 66 71
[email protected] [email protected]

www.hubacontrol.com

You might also like