14 20 00 Hydraulic Passenger Elevator (Garaventa Lift)
14 20 00 Hydraulic Passenger Elevator (Garaventa Lift)
PART 1 GENERAL
I. Section 09 68 00 - Carpeting.
L. Division 16 - Electrical:
1. Electrical characteristics and wiring connections.
2. Electrical service to lockable fused disconnect in elevator machine room.
3. Electrical service for machine room, machine room convenience outlets, machine
room lighting and lighting in elevator pit.
4. Telephone service.
1.3 REFERENCES
A. ASME A17.1 /CSA B-44 - Section 5.2 Safety Code for Elevators and Escalators, Limited-
Use/Limited Application Elevators.
14 20 00-1
B. NFPA 70 - National Electric Code.
C. ADA: Provide passenger elevator in accordance with the requirements of Americans with
Disabilities Act.
1.5 SUBMITTALS
C. Shop Drawings:
1. Show typical details of assembly, erection and anchorage.
2. Include wiring diagrams for power, control, and signal systems.
3. Show complete layout and location of equipment, including required clearances and
coordination with hoistway.
D. Selection Samples: For each finish product specified, two complete sets of color chips
representing manufacturer's full range of available colors and patterns.
B. Review hoistway, electrical, fire alarm and other requirements with appropriate
representatives.
B. Store components off the ground in a dry covered area, protected from adverse weather
conditions.
14 20 00-2
1.8 PROJECT CONDITIONS
A. Do not use elevator for hoisting materials or personnel during construction period.
1.9 WARRANTY
A. Warranty: Provide a two year limited warranty covering replacement of defective parts and
excluding labor. Preventive maintenance agreement required.
B. Extended Warranty: Provide an additional five year limited warranty covering replacement of
defective parts and excluding labor for a total of seven years. Preventive maintenance
agreement required.
A. Furnish service and maintenance for elevator system and components for the following
period from Date of Substantial Completion.
1. One year.
2. Two years.
3. Three years.
4. Four years.
5. Five years.
6. Six years.
7. Seven years.
D. Perform maintenance work using competent and qualified personnel approved by elevator
manufacturer or original installer.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Garaventa Lift; United States - P.O. Box 1769, Blaine, WA
98231-1769. Canada - 7505 134A St., Surrey, BC V3W 7B3. ASD. Tel. Toll Free: 800-663-
6556. Tel: (604) 594-0422. Fax: (604) 594-9915. Email:[email protected].
Web www.garaventalift.com.
A. Garaventa Elvoron LU/LA Hydraulic Elevator, 1,400 pounds (635 kg) capacity cable
hydraulic elevator:
1. Capacity: 1,400 pounds (635 kg).
2. Car Size: Maximum of 18 SF (1.67 sm).
a. Style 1L: 48 inches by 54 inches (1220 by 1372 mm) with one side right sliding
doors.
b. Style 1L: 42 inches by 60 inches (1067 by 1524 mm) with one side right sliding
doors.
14 20 00-3
c. Style 1R: 48 inches by 54 inches (1220 by 1372 mm) with one side left sliding
doors.
d. Style 1R: 42 inches by 60 inches (1067 by 1524 mm) with one side left sliding
doors.
e. Style 2: 48 inches by 54 inches (1220 by 1372 mm) with sliding doors at each
end.
f. Style 2: 42 inches by 60 inches (1067 by 1524 mm) with sliding doors at each
end.
g. Style 3: 51 inches by 51 inches (1295 by 1295 mm) with sliding doors on two
sides.
h. Style 4: 51 inches by 51 inches (1295 by 1295 mm) with sliding doors on two
sides.
3. Travel:
a. _____ feet ____ inches.
b. As indicated on the Drawings.
4. Stops:
a. 2 stops.
b. 3 stops.
c. 4 stops.
d. 5 stops.
e. 6 stops.
f. As indicated on the Drawings.
5. Speed: Nominal 30 feet per minute (0.15 m/sec).
6. Pit Depth: Minimum 14 inches (355 mm) required.
7. Overhead: Total overhead clearance (Refuge Space) 135 inches (3429 mm) above
the finished upper landing floor level. This space allowance can be reduced to 114
inches (2896 mm) with the use of a car top prop.
8. Drive System: 1:2 Cable Hydraulic, Heavy Duty car sling with roller guide shoes
running on 8 lb. per foot steel T-rails, Quiet submersed pump and motor, factory pre-
set and tested 2-speed valve for smooth start and stop.
9. Power Requirements:
a. 230 VAC, 30 Amp, Single Phase.
b. 208 VAC, 20 Amp, Three Phase.
c. A Separate 115-Volt, 15 Amp Circuit is required for car lighting.
10. Controls:
a. Garaventa-Design PLC Controller with integrated self-diagnostics.
b. Fully automatic push button at car and landings with Braille markings..
c. Automatic car light switch upon entry.
d. Digital floor indicator in Car.
e. Car arrival lanterns in car door jamb.
f. Arrival gong.
11. Car and Hoistway Doors: Nominal 36 inch by 80 inch (914 by 2032 mm) two-speed
horizontal sliding hoistway and car doors.
12. Safety Features:
a. Emergency back-up power with a manual lowering device.
b. Safety brake system.
c. Car operator with integral gate switch.
d. Automatic bi-directional floor leveling.
e. Emergency alarm button in car, Emergency keyed stop switch in car.
f. Overspeed valve.
g. Final limit switch.
h. Low oil protection timer circuit.
13. Standard Features:
a. Car direction lantern comes with audio and visual signals.
b. Full height photo-electric door sensors.
c. Automatic home park feature. Home park can be disengaged during
14 20 00-4
installation.
14. Options:
a. Integrated hands free telephone.
b. Fireman service (Phase 1).
c. Car top prop (required where overhead clearance is less than 135 inches).
d. Buffer springs (increases your pit depth).
e. Keyed hoistway access
15. Machine Location:
a. As indicated on the Drawings.
A. Cab Design:
1. Interior Walls: Laminate panel sections.
a. Designer White.
b. Dove Gray.
c. Cloud Nebula.
d. Kensington Maple.
e. New Age Oak.
f. Empire Mahogany.
g. Custom Laminate as selected by the Architect.
2. Cab Frame:
a. Mild steel powder coated black.
b. Mild steel powder coated white.
c. Stainless Steel.
d. Mild steel powder coated in a custom color as selected by the Architect.
3. Ceiling Finish:
a. White.
b. Stainless Steel, brushed finish.
c. Mild steel powder coated in a custom color as selected by the Architect.
4. Handrail Finish:
a. Stainless Steel, brushed finish.
5. Car Operating Panel Finish:
a. Stainless Steel, brushed finish.
6. Floor: Unfinished plywood construction.
7. Lighting: Four recessed LED down lights.
a. White Trim.
b. Black Trim.
c. Chrome Trim.
8. Car Direction Lantern: Stainless car direction lantern complete with auto and visual
signaling device indicating direction of travel and arrival at selected floor.
9. Car Doors: When open the doors provide a 36 inch (915 mm) by 80 inch (2032 mm)
clear opening.
a. Two Speed Horizontal Sliding equipped with full height photo-electric door
sensors, color as follows:
1) Matching cab wall finish.
2) Stainless steel, brushed finish.
A. Hoistway Entrances: When open, the doors provide a 36 inch (915 mm) by 80 inch (2032
mm) clear opening.
1. Two Speed Horizontal Sliding doors, finished as follows:
a. Primed painted.
b. Stainless Steel, brushed finish.
14 20 00-5
1. Hall Station Type:
a. Keyless Push Button.
b. Keyed Push Button.
2. Finish:
a. Stainless Steel, brushed finish.
PART 3 EXECUTION
3.1 EXAMINATION
A. Do not begin installation until preliminary work including hoistway, landings and machine
space has been properly prepared.
B. Verify hoistway is constructed in accordance with ASME A17.1 /CSA B-44 and all local
codes.
D. Verify machine room, when required, is provided with lighting, light switch, convenience
outlets and clear space requirements of all local codes.
E. Verify hoistway and openings are of correct size and within tolerance.
3.2 PREPARATION
B. Prepare surfaces using the methods recommended by the manufacturer for achieving the
best result for the substrate under the project conditions.
3.3 INSTALLATION
A. Perform tests in compliance with ASME A 17.1 /CSA B-44 and as required by authorities
having jurisdiction.
B. Schedule tests with agencies and Architect, Owner, and Contractor present.
14 20 00-6
A. Obtain required permits to perform tests. Perform tests required by regulatory agencies.
3.6 ADJUSTING
A. Adjust for smooth acceleration and deceleration of car so not to cause passenger
discomfort.
B. Adjust automatic floor leveling feature at each floor to provide stopping zone of 1/4 inch (6
mm).
3.7 CLEANING
3.8 PROTECTION
END OF SECTION
14 20 00-7