0% found this document useful (0 votes)
109 views33 pages

D-Agent - 1 - Work-104-S-Upload-3300 XL NSV Proximity Transducer System Datasheet - 147385

The 3300 XL NSv Proximity Transducer System is intended for use on machines with tight installation spaces, such as compressors. It consists of a probe, extension cable, and Proximitor Sensor. The system provides radial and axial vibration monitoring and position measurements. It has improved chemical resistance and side-view characteristics compared to previous models, allowing use in more applications. Key specifications include a linear range of 1.5mm and operating voltage between -17.5Vdc and -26Vdc.

Uploaded by

ramiro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
109 views33 pages

D-Agent - 1 - Work-104-S-Upload-3300 XL NSV Proximity Transducer System Datasheet - 147385

The 3300 XL NSv Proximity Transducer System is intended for use on machines with tight installation spaces, such as compressors. It consists of a probe, extension cable, and Proximitor Sensor. The system provides radial and axial vibration monitoring and position measurements. It has improved chemical resistance and side-view characteristics compared to previous models, allowing use in more applications. Key specifications include a linear range of 1.5mm and operating voltage between -17.5Vdc and -26Vdc.

Uploaded by

ramiro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 33

3300 XL NSv Proximity Transducer System

Datasheet
Bently Nevada Machinery Condition Monitoring 147385 Rev. N

Description
The 3300 XL NSv Proximity Transducer system is intended for
use with centrifugal air compressors, refrigeration
compressors, process gas compressors, and other machines
with tight installation requirements. The 3300 XL NSv Proximity
Transducer System consists of:

l a 3300 NSv probe

l a 3300 NSv extension cable

l a 3300 XL NSv Proximitor Sensor(1)

The primary uses for the 3300 XL NSv Transducer System are
for areas where counter bore, sideview, or rearview
restrictions limit the use of standard Bently Nevada 3300 and
3300 XL 5 and 8 mm Transducer Systems. It is also ideal for
small target applications, such as measuring radial vibration
on shafts smaller than 51 mm (2 in) or axial position on flat
targets smaller than 15 mm (0.6 in). It is primarily used in the
following applications on fluid-filmed bearing machines
where a small shaft or reduced side-view is present:

l Radial vibration and radial position measurements

l Axial (thrust) position measurements

l Tachometer and zero speed measurements

l Phase reference (Keyphasor signals)


The 3300 XL NSv Transducer System design allows it to replace
both the 3300 RAM Transducer Systems and the 3000-series
or 7000-series 190 Transducer System. Upgrades from the
3300 RAM system to the 3300 XL NSv system may use the
existing probe, extension cable, and monitoring system with
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N
3300 XL NSv Proximitor Sensor. Upgrades from compressor applications. The side-view
the 3000-series or 7000-series Transducer characteristics of the 3300 NSv probe are also
System must replace the probe, extension superior to those of the 3000-series 190 probe
cable, and Proximitor Sensor with NSv when gapping the 3300 NSv probe at the same
components. distance from the probe target.

The 3300 XL NSv Transducer System has an The 3300 NSv probe comes in varying probe
Average Scale Factor of 7.87 V/mm (200 case configurations, including armored and
mV/mil), which is the most common output for unarmored 1/4-28, 3⁄8-24, M8X1 and M10X1
eddy current transducers. Its enhanced side- probe threads. The reverse mount 3300 NSv
view and small target characteristics give it a probe comes standard with either 3⁄8-24 or
shorter linear range than the Bently Nevada M10X1 threads. All components of the
3300 XL-series 5 and 8 mm Transducer System. transducer system have gold-plated brass
The 1.5 mm (60 mils) of linear range exceeds the ClickLoc connectors. ClickLoc connectors lock
linear range of the 3000-series 190 Transducer into place and prevent the connection from
System. loosening. The patented TipLoc molding
method provides a robust bond between the
Although the terminals and probe tip and the probe body. Bently Nevada’s
connector on the Proximitor Sensor patented CableLoc design provides 220 N (50
have protection against electrostatic lb) of pull strength and securely attaches the
discharge, take reasonable probe cable to the probe tip. Connector
precautions to avoid electrostatic protectors are recommended for use on the
discharge during handling. probe-to-extension cable connection, as well
as on the cable-to-Proximitor Sensor
connection. Connector protectors prevent
Proximitor Sensor most liquids from entering into the ClickLoc
connectors and adversely affecting the
The 3300 XL NSv Proximitor Sensor has similar
electrical signal(2).
features to those found in the 3300 XL 8 mm
Proximitor Sensor. Its thin design allows the user Notes:
to mount it in either a high-density DIN-rail
installation or a more traditional panel mount (1) Proximitor Sensors are supplied by default
configuration. Improved RFI/EMI immunity from the factory calibrated to AISI 4140 steel.
allows the 3300 XL NSv Proximitor Sensor to Calibration to other target materials is available
achieve European CE mark approvals without upon request.
any special mounting considerations. This RFI
immunity also prevents nearby high frequency (2) Silicone tape is also provided with each
radio signals from adversely affecting the 3300 NSv extension cable and can be used
transducer system. SpringLoc terminal strips instead of connector protectors. Silicone tape is
on the Proximitor Sensor require no special not recommended in applications where the
installation tools and facilitate faster, highly probe-to-extension cable connection will be
robust field wiring connections. exposed to turbine oil.

Proximity Probe and Extension


Cable
The 3300 NSv probe and extension cable are
mechanically and electrically compatible and
interchangeable with Bently Nevada’s previous
3300 RAM proximity probe and extension cable.
The NSv probe has increased chemical
resistance compared to the 3300 RAM probe,
which allows its use in many process

2/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

7.0 5.9 ± 0.9


Specifications Center conductor: 0.220
Ω/m (0.067 Ω/ft)
Unless otherwise noted, the following Extension cable
specifications are for a 3300 XL NSv Proximitor dc resistance
Shield: 0.066 Ω/m (0.020
Sensor, extension cable and probe between 0°C
Ω/ft)
and +45°C (+32°F to +113°F) at a maximum
altitude of 2000 m, with a -24 Vdc power supply, Extension cable
a 10 kΩ load, a Bently Nevada supplied AISI 4140 69.9 pF/m (21.3 pF/ft) typical
capacitance
steel target that is 31 mm (1.2 in) diameter or
larger, and a probe gap of 1.0 mm (40 mils). The 0.2 to 1.5 mm2 (16 to 24 AWG)
system accuracy and interchangeability [0.25 to 0.75 mm2 (18 to 23
specifications do not apply when using a AWG) with ferrules].
transducer system calibrated to any target Recommend using three-
other than a Bently Nevada AISI 4140 steel conductor shielded triad
target. cable. Maximum length of
305 meters (1,000 feet)
Electrical Field Wiring between the 3300 XL NSv
Proximitor Sensor and the
Accepts one non- monitor. See the frequency
Proximitor contacting 3300 RAM or response graphs Figure 16
Sensor Input 3300 NSv Proximity Probe and Figure 17 for signal rolloff
and Extension Cable. at high frequencies when
using longer field wiring
Requires -17.5 Vdc to -26 Vdc lengths.
without barriers at 12 mA
maximum consumption, - 1.5 mm (60 mils). Linear
23 Vdc to range begins at
Power -26 Vdc with barriers. approximately 0.25 mm (10
Operation at a more positive Linear Range mils) from target and is from
voltage than -23.5 Vdc can 0.25 to 1.75 mm (10 to 70
result in reduced linear mils) (approximately -1 to -
range. 13 Vdc).
Less than 2 mV change in Recommended
Supply 1.0 mm (40 mils)
output voltage per volt Gap Setting
Sensitivity
change in input voltage.
System performance over ambient
Output temperature range (0°C to 45°C)
50 Ω
resistance
7.87 V/mm (200 mV/mil)
Probe dc Resistance +12.5%/-20% including
Incremental interchangeability error
Resistance from the Center Scale Factor when measured in
Probe Length
Conductor to the Outer (ISF) increments of 0.25 mm (10
(m)
Conductor (RPROBE) (ohms) mils) over the 1.5 mm (60
0.5 4.0 ± 0.5 mil) linear range.

1.0 4.2 ± 0.5 Deviation from


Less than ±0.06 mm (±2.3
best fit straight
mils).
5.0 5.3 ± 0.7 line (DSL)

3/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

0 to 10 kHz: +0, -3 dB typical, Minimum (standard X-Y


Frequency
with up to 305 meters (1000 probe configuration): 30
Response
feet) of field wiring. mm (1.2 in)

Minimum: 8.9 mm (0.35 in) Minimum (X-Y proximity


diameter probes offset axially by 23
mm (0.9 in)): 20 mm (0.8 in)
Recommended minimum: 13
mm (0.5 in) diameter Measurements on shaft
diameters smaller than 30
Axial position mm (1.2 in) usually require
measurements on shaft close spacing of radial
Target Size (flat
diameters smaller than vibration or axial position
target)
13mm (0.5 in) will generally transducers. This creates the
result in a change in scale potential for their
factor. Reducing the gap electromagnetic emitted
between the probe and fields to interact with one
target will help limit the another (cross-talk),
change in scale factor. See resulting in erroneous
Figure 12 for additional readings. To prevent cross-
information. Shaft Diameter
talk, maintain minimum
separation of transducer
tips of at least 25 mm (1.0 in)
for axial position
measurements or 23 mm
(0.9 in) for radial vibration
measurements. See Figure
14: Probe Cross-talk with
Probes Mounted in Parallel
and Figure 15: Probe Cross-
talk with Probes Mounted in
X-Y Configuration. Radial
vibration or radial position
measurements on shaft
diameters smaller than 20
mm (0.8 in) will generally
result in greater than a 10%
change in Average Scale
Factor (ASF). See Figure 13
for additional information.

4/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Minimum: 9.5 mm (0.375 in) Proximitor


Sensor A380 aluminum
Recommended minimum: 13 Material
mm (0.5 in)
System 5 or 7 meters including
Counterbores smaller than Length extension cable
13 mm (0.5 in) generally
Extension
result in a change in scale Flexible AISI 302 SST
Counterbore Cable Armor
factor at far gaps. Reducing with/without FEP outer jacket.
(optional)
the gap between the probe
and the target will allow the 220 N (50 lb) probe case to
transducer system to Tensile probe lead. 220 N (50 lb) at
maintain its Average Scale Strength probe lead to extension cable
Factor (ASF) over a reduced (maximum connectors. 220 N (50 lb)
linear range. See Figure 9 for rated) probe case to stainless steel
additional information. armor.

Connector
Effects of 60 Hz Magnetic Fields Up to 300 Gold-plated brass
material
Gauss (5 meter system)
Recommended case hole and tap size for
Output voltage in mil pp/gauss 1/4-28 case
Proximitor Drill Size 0.213 in
Gap Probe Ext. Cable
Sensor
Hole Size 0.218 to 0.222 in
0.25 mm
0.006 0.001 0.001
(10 mils) Hole Depth 0.376 to 0.750 in
1.0 mm Tap Drill Size #3
0.007 0.002 0.001
(40 mils)
Recommended case hole and tap size for
1.75 mm M8X1 case
0.008 0.002 0.003
(70 mils)
Drill Size 7.4 mm
Mechanical Hole Size 7.511 to 7.622 mm

Probe Tip Hole Depth 12 to 24 mm


Polyphenylene sulfide (PPS).
Material
Tap Drill Size L
Probe Case
AISI 304 stainless steel (SST). Recommended case hole and tap size for
Material
3/8-24 case
75 Ω coaxial, fluoroethylene
propylene (FEP) insulated Drill Size 0.332 in
Probe Cable
probe cable in the following
Specifications Hole Size 0.338 to 0.343 in
total probe lengths: 0.5, 1, 5, or
7 meters. Hole Depth 0.562 to 1.125 in
Extension Tap Drill Size Q
75 Ω coaxial, fluoroethylene
Cable
propylene (FEP) insulated.
Material

5/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Recommended case hole and tap size for Armored


M10X1 case Extension 64 g/m (0.7 oz/ft)
Cable
Drill Size 9.4 mm
Proximitor
Hole Size 9.541 to 9.662 mm 255 g (9 oz)
Sensor
Hole Depth 15 to 30 mm
Environmental Limits
Tap Drill Size U
Probe Temperature Range
Connector-to-connector Torque Operating -52°C to +177°C (-62°F to
Temperature +351°F)
Probe Case Maximum
Recommended
Torque Rated -52°C to +177°C (-62°F to
+351°F)
1/4-28 or 7.3 N•m 5.1 N•m
M8X1 probe
(65 in•lb) (45 in•lb) Exposing the probe to
cases
temperatures below
Storage
3/8-24 or -34°C (-30°F) for a
33.9 N•m 11.3 N•m Temperature
M10X1 probe sustained period of
cases (300 in•lb) (100 in•lb) time may cause
premature failure of
3/8-24 or the pressure seal.
M10X1 probe 22.6 N•m 7.5 N•m
cases – first (200 in•lb) (66 in•lb)
three threads Extension Cable Temperature Range

Reverse Operating
22.6 N•m 7.5 N•m -52°C to +177°C (-62°F to
mount and Storage
+351°F)
probes (200 in•lb) (66 in•lb) Temperature

Proximitor Sensor Temperature Range


Recommended
Finger tight Operating -52°C to +100°C (-62°F to
torque
Temperature +212°F)
Maximum
0.56 N•m (5 in•lb) Storage -52°C to +105°C (-62°F to
torque
Temperature +221°F)
Minimum Bend
Radius (with or 100% condensing, non-
25.4 mm (1.0 in) Relative submersible when connectors
without sst
armor) Humidity are protected.Tested to IEC 68-
2-3 damp heat.
System Weight (typical)

Approximately 14 to 150 g
Probe
(0.5 to 5.3 oz)

Extension
45 g/m (0.5 oz/ft)
Cable

6/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

3300 NSv probes are designed


to seal differential pressure
between the probe tip and
case. The probe sealing
material consists of a Viton O-
Probe
ring. Probes are not pressure
Pressure
tested prior to shipment.
Contact our custom design
department if you require a
test of the pressure seal for
your application.

It is the responsibility of the


customer or user to ensure that all
liquids and gases are contained
and safely controlled should
leakage occur from a proximity
probe.In addition, solutions with
high or low pH values may erode the
tip assembly of the probe causing
media leakage into surrounding
areas. Bently Nevada will not be held
responsible for any damages
resulting from leaking 3300 NSv
Proximity Probes. In addition, 3300
NSv Proximity Probes does not be
replaced under the service plan due
to probe leakage.

7/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Hazardous Area Approvals


Compliance and For the detailed listing of country and
Certifications product specific approvals, refer to
the Approvals Quick Reference Guide
FCC (108M1756) available from Bently.com.
This device complies with part 15 of the
FCC Rules. Operation is subject to the cNRTLus
following two conditions:

l This device may not cause harmful 3300 XL Proximitor Sensor


interference.
l This device must accept any ia Class I, Zone 0: AEx/Ex ia IIC T4/T5 Ga;
Class I, Groups A, B, C, and D,
interference received, including Class II, Groups E, F and G,
When installed
interference that may cause with Class III;
undesired operation. intrinsically
safe zener T5 @ Ta= -55°C to + 40°C.
T4 @ Ta= -55°C to + 80°C.
EMC barriers per
drawing 141092
or when
European Community Directive: installed with
galvanic
EMC Directive 2014/30/EU isolators.
Standards nA, ec Class I, Zone 2: AEx/Ex nA IIC T4/T5
Gc;
EN 61000-6-2; Immunity for When installed Class I, Division 2, Groups A, B, C, and
Industrial Environments with non- D;
incendive Class I, Zone 2: AEx/Ex ec llC T4/T5
EN 61000-6-4; Emissions for circuit Gc;
Industrial Environments connected per Class I, Division 2, Groups A, B, C, and
drawing D;
140979.
RoHS T5 @ Ta= -55°C to + 40°C
T4 @ Ta= -55°C to + 80°C
European Community Directive:
RoHS Directive 2011/65/EU 3300 XL Probe
Maritime
ia Class I, Zone 0: AEx/Ex ia IIC T5...T1 Ga;
2019 Rules for Conditions of Classification, Class 1, Groups A, B. C, and D,
When installed Class II, Groups E, F, and G,
Part 1, 1-1-1/7.7, 1-1-A3, 1-1-A4 with Class III;
intrinsically
(see Temperature Schedule table to
2019 Rules for Conditions of Classification, safe zener
follow)
barriers per
Part 1, Offshore Units and Structures drawing 141092
or when
1-1-4/9.7, 1-1-A2, 1-1-A3 installed with
galvanic
Functional Safety isolators.

SIL 2, HFT = 0
SIL 3, HFT = 1

8/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Class I, Zone 2: AEx/Ex nA IIC T5…T1 Gc; ia


Class 1, Division 2, Groups A, B, C, D;
nA, ec Class 1, Zone 2: AEx/Ex ec llC T5…T1 II 1 G
Gc; Class I, Division 2, Groups A, B, C, Ex ia IIC T5…T1 Ga,
When installed (see Temperature Schedule
with non- and D;
table to follow)
incendive (see Temperature Schedule table to
circuit follow) Ex ia IIIC T90°C ... T280°C Dc
connected per For EPL Dc:
drawing
140979. Ui= -28V Ci = 1.5 nF

ATEX/IECEx Ii = 140 mA Li =610 μH

Pi = 0.91 W
3300 XL Proximitor Sensor
nA,ec
ia II 3 G
Ex nA IIC T5…T1 Gc,
II 1 G Ex ec llC T5…T1 Gc,
Ex ia IIC T4/T5 Ga (see Temperature Schedule
Ex ia IIIC T90C/T105C Dc table to follow)
For EPL Dc:
T105C @ Ta = -55°C to 100°C
T90C @ Ta = -55°C to +85°C Ui= -28V li= 140 mA

Ui= -28V Uo= -28V


Temperature Schedule
Ii= 140mA Io= 140mA

Pi= 0.91W Po= 0.742W Temperature Ambient Temperature


Classification (Probe Only)
Ci- 47nF Co= 1.5nF
For EPL Ga and Gc
Li= 1460µH Lo= 610µH
T1 -55°C to +232°C
nA,ec -55°C to +177°C
T2
II 3 G
Ex nA IIC T4/T5 Gc T3 -55°C to +120°C
Ex ec llC T4/T5 Gc
T4 -55°C to +80°C
Ui= -28V li= 140 mA
T5 -55°C to +40°C
T5 @ Ta= -55˚ C to + 40˚C
T4 @ Ta= -55 ˚C to + 80˚C For EPL Dc

T280°C @ Ta -55°C to +232°C


3300 XL Probe
T225°C @ Ta -55°C to +177°C

T170°C @ Ta -55C to +120°C


Probe entity parameters are met
when used with BN extension cables T130°C @ Ta -55°C to +80°C
and connected to BN Prox.
T105°C @ Ta -55°C to +100°C

T90°C @ Ta -55°C to +40°C

9/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Hazardous Area Conditions of


Safe Use
cNRTLus:
ia
Install per Bently Nevada drawing 141092.
nA, ec
Install per Bently Nevada drawing 140979.

ATEX/IECEx:
ia
Install per Bently Nevada drawing 141092.
nA, ec
The Proximitor must be installed so as to
provide the terminals with a degree of
protection of at least IP54.

10/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

05 0.5 meter (20 in)


Ordering Information 10 1.0 meter (39 in)

For the detailed listing of country and 50 5.0 meter (16.4 feet)
product specific approvals, refer to
the Approvals Quick Reference Guide 70 7.0 meter (23.0 feet)
(108M1756) available from Bently.com.
D: Connector and Cable-Type Option

Miniature coaxial ClickLoc connector


3300 NSv Proximity Probes 01 with connector protector, standard
cable
330901 3300 NSv Probe, 1/4-28 UNF thread,
without armor Miniature coaxial ClickLoc connector,
02
standard cable
330902 3300 NSv Probe, 1/4-28 UNF thread,
with armor Miniature coaxial ClickLoc connector
11 with connector protector, FluidLoc
330908 3300 NSv Probe, 3/8-24 UNF thread, cable
without armor
Miniature coaxial ClickLoc connector,
330909 3300 NSv Probe, 3/8-24 UNF thread, 12
FluidLoc cable
with armor
E: Agency Approval Option
Part Number-AA-BB-CC-DD-EE
00 Not required
A: Unthreaded Length Option
05 Multiple Approvals
Unthreaded length must be
at least 0.7 inch less than the
case length.
3300 NSv Proximity Probes, Metric
Order in increments of 0.1 in
330903 3300 NSv Probe, M8X1 thread, without
Length configurations: armor

Maximum unthreaded length: 9.2 in 330904 3300 NSv Probe, M8X1 thread, with
armor
Minimum unthreaded length: 0.0 in
330905 3300 NSv Probe, M10X1 thread,
Example: 0 4 = 0.4 in
without armor
B: Overall Case Length Option
330910 3300 NSv Probe, M10X1 thread, with
Order in increments of 0.1 in armor

Threaded length configurations: Part Number-AA-BB-CC-DD-EE

Maximum case length: 9.9 in A: Unthreaded Length Option


Minimum case length: 0.8 in
Example: 2 4 = 2.4 in

C: Total Length Option

11/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Miniature coaxial ClickLoc connector,


Unthreaded length must be 12
FluidLoc cable
at least 20 mm less than the
case length. E: Agency Approval Option

00 Not required
Order in increments of 10 mm.
05 Multiple Approvals
Length configuration:
Maximum unthreaded length: 3300 NSv Reverse Mount Probe
230 mm
330906-02-12-CC-DD-EE 3/8-24 UNF threads
Minimum unthreaded length:
330907-05-30- CC-DD-EE M10X1 threads
0 mm
C: Total Length Option
Example:
05 0.5 meter (20 in)
0 6 = 60 mm
10 1.0 meter (39 in)
B: Overall Case Length Option
50 5.0 meter (16.4 feet)
Order in increments of 10 mm.
Metric thread configurations: 70 7.0 meter (23.0 feet)

Maximum length: 250 mm D: Connector Option

Minimum length: 20 mm Miniature coaxial ClickLoc


02
connector, standard cable
Example: 0 6 = 60 mm
Miniature coaxial ClickLoc
C: Total Length Option 12
connector, FluidLoc cable
05 0.5 meter (20 in) E: Agency Approval Option
10 1.0 meter (39 in) 00 Not required
50 5.0 meter (16.4 feet) Multiple Approvals
70 7.0 meter (23.0 feet)
For a shorter delivery
D: Connector and Cable-Type Option time, order commonly
stocked probes.
Miniature coaxial ClickLoc connector Currently, stocked
01 with connector protector, standard probes consist of the
cable following part
numbers: 330901-00-
Miniature coaxial ClickLoc connector, 05
02 24-05-02-00, 330901-
standard cable 00-90-05-02-00,
330902-00-50-05-02-
Miniature coaxial ClickLoc connector
00, 330902-00-95-05-
11 with connector protector, FluidLoc
02-00, 330903-00-02-
cable
10-02-00, 330903-00-
03-10-02-00, 330906-
02-12-05-02-00.

12/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

3300 XL NSv Proximitor Sensor With stainless steel armor, with


01
FEP jacket
330980-AA-BB
With stainless steel armor,
02
A: Total Length and Mounting Option without FEP jacket

5.0 meter (16.4 feet) system Without stainless steel armor,


50 03
length, panel mount with connector protector

5.0 meter (16.4 feet) system With stainless steel armor, with
51
length, DIN mount 04 FEP jacket, with connector
protector
5.0 meter (16.4 feet) system
52
length, no mounting hardware1 With stainless steel armor,
05 without FEP jacket, with
7.0 meter (23.0 feet) system connector protector
70
length, panel mount
FluidLoc cable without stainless
7.0 meter (23.0 feet) system 06
71 steel armor
length, DIN mount
FluidLoc cable with stainless
7.0 meter (23.0 feet) system 07
72 steel armor, with FEP jacket
length, no mounting hardware1
FluidLoc cable with stainless
B: Agency Approval Option 08
steel armor, without FEP jacket
00 Not required FluidLoc without stainless steel
09
armor, with connector protector
05 Multiple approvals
FluidLoc cable with stainless
10 steel armor, with FEP jacket, with
connector protector
3300 NSv Extension Cable
FluidLoc cable with stainless
330930-AAA-BB-CC 11 steel armor, without FEP jacket,
with connector protector
Make sure that the extension cable
length and the probe length, when C: Agency Approval Option
added together, equal the
00 Not Required
Proximitor Sensor total length.
05 Multiple Approvals
A: Cable Length Option

040 4.0 meter (13.1 feet)

045 4.5 meter (14.8 feet)

060 6.0 meter (19.7 feet)

065 6.5 meter (21.3 feet)

B: Connector and Cable Option

00 Without stainless steel armor

13/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Accessories Connector Protector Adapter.


Allows connector protector
3300 XL NSv Proximitor User 136536-01 installation tools manufactured
147357
Guide prior to 1998 to be used with 75 Ω
ClickLoc connectors.
Bulk field wire. 1.0 mm2 (18 AWG),
3 conductor, twisted, shielded Connector Protectors. Package
02120015
cable with drain wire. Specify 40180-03 contains 10 pairs of connector
length in feet. protectors.

Replacement panel-mount Male Connector Protector.


138492-01
mounting pad Placed on the extension cable to
connect to the female
Replacement DIN-mount 03800000 connector protector on the
138493-01
mounting pad probe and provide
environmental protection of
01609137 BNC (F) to banana plugs
connectors.
Proximitor Connector Test Pin
Female Connector Protector.
01609138 wiring (two test pins to a BNC (F)
Placed on the probe lead to
connector)
connect to the male connector
50 Ω cable with two BNC (M) protector on the extension cable
connectors. Use this cable in and provide environmental
03800001
combination with adapter protection of connectors. Also
40971-04 01609137 and adapter 01609138 placed on the extension cable to
when checking performance of slide over the Proximitor Sensor
the transducer system from the connection and protect it from
Proximitor Sensor test pin holes. the environment.

3300 XL Proximitor Sensor Panel- 3300 NSv Connector Kit. Used on


mount Screws. Package 3300 NSv probes and extension
includes one 6-32 UNC thread cables. Contains one set of male
330153-05
04310310 forming mounting screw and female ClickLoc connectors,
(supplied standard with 3300 XL sleeves and one strip of silicone
Proximitor Housings [3300 XL tape.
option]).
Connector Crimp Tool Kit.
Silicone self-fusing tape. A 9.1 Includes one set of 75 Ω ClickLoc
meter (10 yard) roll of silicone inserts and connector
tape to protect connectors. It is installation instructions.
easy to install and provides Supplied with carrying case.
03200006 excellent electrical isolation and
Notes:
protection from the
163356 1. 330980 Proximitor Sensor A:
environment. It is not
options 52 and 72 come without
recommended for use inside the
a mounting pad and should be
casing of the machine.
ordered only as spares. Each
Connector Protector Kit for 3300 Proximitor Sensor needs a
NSv probes and extension mounting pad to ensure that it
40113-03 is properly isolated from the
cables, including connector
protectors and installation tools. housing ground.

14/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Graphs and Figures

Figure 1: Typical 3300 XL NSv 5m System over Ambient Temperature Range

15/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 2: Typical 3300 XL NSv 7m System over Ambient Temperature Range

16/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 3: Typical 3300 NSv Probe + 1m Cable @ Low Temperature (Proximitor Sensor + 4m of
Extension Cable @ 25°C)

17/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 4: Typical 3300 NSv Probe + 1m Cable @ High Temperature (Proximitor Sensor + 4m of
Extension Cable @ 25°C)

18/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 5: Typical 3300 XL NSv 5m Proximitor Sensor with 4 m of Extension Cable @ Low
Temperature (Probe is at 25°C)

19/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 6: Typical 3300 XL NSv 5m Proximitor Sensor with 4 m Extension Cable @ High Temperature
(Probe is at 25°C)

20/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 7: Typical 3300 XL NSv 7m Proximitor Sensor with 6 m of Extension Cable @ Low
Temperature (Probe is at 25°C)

21/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 8: Typical 3300 XL NSv 7m Proximitor Sensor with 6 m of Extension Cable @ High
Temperature (Probe is at 25°C)

22/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 9: Effect of Counterbore Side Clearance (4140 Material)

23/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 10: Effect of Flat Surface Side Clearance (4140 Material)

24/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 11: Effect of Rear Surface Clearance (4140 Material)

25/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 12: Axial Sensitivity to Shaft Size

Figure 13: Radial Sensitivity to Shaft Size

26/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 14: Probe Cross-talk with Probes Mounted in Parallel

Figure 15: Probe Cross-talk with Probes Mounted in X-Y Configuration

27/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 16: Frequency Response, magnitude of typical 3300 XL NSv System with various lengths of
field wiring, no barriers

Figure 17: Frequency Response, phase change of typical 3300 XL NSv System with various lengths
of field wiring, no barriers

28/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 18: 3300 NSv Proximity probes, Standard Mount


330901, 1/4-28 UNF-2A, without armor
330902, 1/4-28 UNF-2A, with armor
330903, M8X1 thread, without armor
330904, M8X1 thread, with armor
330905, M10X1 thread, without armor
330908, 3/8-24 UNF-2A, without armor
330909, 3/8-24 UNF-2A, with armor
330910, M10X1 thread, with armor

Note: Connector Protector only installed on female end when optioned. Both ends available as
accessories.
Figure 19: Installed Connector Protectors

29/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 20: 3300 NSv Proximity Probes, Reverse Mount


330906, 3/8-24 UNF-2A threads
330907, M10X1 threads

Figure 21: 330930, 3300 NSv Extension Cable

30/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Figure 22: Panel Mount 3300 XL NSv Proximitor Sensor

Figure 23: DIN Mount 3300 XL NSv Proximitor Sensor

31/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N
Notes:

1. All dimensions on figures are in millimeters (inches) unless otherwise noted.


2. Standard mount 1/4 -28 UNF thread probes are supplied with 7/16 inch lock nut and
7/32 wrench flats.
3. Standard mount M8x1 thread probes are supplied with 13 mm lock nut and 7 mm
wrench flats.
4. Standard mount 3/8-24 UNF thread probes are supplied with 9/16 inch lock nut and
5/16 wrench flats.
5. Standard mount M10X1 thread probes are supplied with 17 mm lock nut and 8 mm
wrench flats.
6. Reverse mount probes are not available with armor or connector protector options.
7. Letters inside quotation marks on figures refer to probe ordering options.
8. Stainless steel armor is supplied with or without FEP outer jacket.
9. FEP jacket is standard on all non-armored probes.

32/33
3300 XL NSv Proximity Transducer System
Datasheet 147385 Rev. N

Copyright 2023 Baker Hughes Company. All rights reserved.

Bently Nevada, Keyphasor, M2, Proximitor and Orbit Logo are registered trademarks of Bently Nevada, a Baker Hughes
business, in the United States and other countries. The Baker Hughes logo is a trademark of Baker Hughes Company.
All other product and company names are trademarks of their respective holders. Use of the trademarks does not
imply any affiliation with or endorsement by the respective holders.
Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not
make any representation as to the accuracy or completeness of the information and makes no warranties of any
kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness
for a particular purpose or use. Baker Hughes hereby disclaims any and all liability for any direct, indirect,
consequential or special damages, claims for lost profits, or third party claims arising from the use of the
information, whether a claim is asserted in contract, tort, or otherwise. Baker Hughes reserves the right to make
changes in specifications and features shown herein, or discontinue the product described at any time without
notice or obligation. Contact your Baker Hughes representative for the most current information.
The information contained in this document is the property of Baker Hughes and its affiliates; and is subject to
change without prior notice. It is being supplied as a service to our customers and may not be altered or its content
repackaged without the express written consent of Baker Hughes. This product or associated products may be
covered by one or more patents. See Bently.com/legal.

1631 Bently Parkway South, Minden, Nevada USA 89423


Phone: 1.775.782.3611 (US) or Bently.com/support
Bently.com

33/33

You might also like