0% found this document useful (0 votes)
51 views1 page

PVG 32 Proportional Valve Group General Description: Technical Information

This document provides a technical description of the PVG 32 Proportional Valve Group. It includes general information about electrical and hydraulic remote control units used with the valve group. It also describes how the PVG 32 functions with an open center fixed displacement pump. When actuated, the highest load pressure is fed through a shuttle valve circuit to partially close the connection to tank and maintain pump pressure. A pressure relief valve opens if the load pressure exceeds the set value. Pressure compensation and load drop check valves are also described.

Uploaded by

jon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
51 views1 page

PVG 32 Proportional Valve Group General Description: Technical Information

This document provides a technical description of the PVG 32 Proportional Valve Group. It includes general information about electrical and hydraulic remote control units used with the valve group. It also describes how the PVG 32 functions with an open center fixed displacement pump. When actuated, the highest load pressure is fed through a shuttle valve circuit to partially close the connection to tank and maintain pump pressure. A pressure relief valve opens if the load pressure exceeds the set value. Pressure compensation and load drop check valves are also described.

Uploaded by

jon
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Technical Information

PVG 32 Proportional Valve Group

General description

Electrical and hydraulic remote control units

PVRE, electrical control unit, 162F… PVRH, hydraulic control unit, 155N…

155N0003 155N0001 155N0004 155N0005 155N0002

PVREL, electrical control unit, 155U… PVRES, electrical control unit, 155B…

Prof 1, 162F…

PVG 32 with open center PVP


PVG 32 with open center PVP (fixed displacement pump) and PVB with flow control spool.
When the pump is started and the main spools in the individual basic modules (11) are in the neutral
position, oil flows from the pump, through connection P, across the pressure adjustment spool (6) to
tank.
The oil flow led across the pressure adjustment spool determines the pump pressure (stand-by pressure).
When one or more of the main spools are actuated, the highest load pressure is fed through the shuttle
valve circuit (10) to the spring chamber behind the pressure adjustment spool (6), and completely or
partially closes the connection to tank to maintain pump pressure.
Pump pressure is applied to the right-hand side of the pressure adjustment spool (6).
The pressure relief valve (1) will open should the load pressure exceed the set value, diverting pump flow
back to tank.
In a pressure-compensated basic module the compensator (14) maintains a constant pressure drop
across the main spool – both when the load changes and when a module with a higher load pressure is
actuated.
With a non pressure-compensated basic module incorporating a load drop check valve (18) in channel P,
the check valve prevents return oil flow.
The basic module can be supplied without the load drop check valve in channel P for functions with over-
center valves.
The shock valves PVLP (13) with fixed setting and the suction valves PVLA (17) on ports A and B are used
for the protection of the individual working function against overload and/or cavitation.