PROCESS DESIGN PROJECT DTS-402
Rev. By Date
DIQUIMA TECHNICAL STANDARD
0 IMV 12/02/01
1. General
This process criteria governs the general requirements for the process design of heat exchangers. A
process design data sheet using DTS-302 shall be prepared for each unit.
2. Design criteria
Square pitch will be specified, for easier cleaning, when the shell side fouling factor is 0.0004
h.◦ C.m2/kcal or greater.
U tubes will be specified when the tube side fouling factor is less than 0.0004 h.◦ C.m2/kcal.
Unless another value is specified, turndown ratio of 40% will be taken into account. Specially heat
exchangers shall be checked in this regard.
Overhead condensers have to be oversized to take into account the greater of either 110% of the
estimated operating duty or the duty increase of the corresponding reboiler.
To take into account the risk of undersizing of heat recovery systems (i.e. feed effluent, feed-bottom),
the following oversizing is typically specified:
• Effluent cooler (or feed preheater): 10% of cooler duty (or preheater duty) or 5% of feed/effluent
exchange duty, whichever is greater.
• Bottom cooler: 10% of cooler duty or 5% of feed/bottom exchange duty, whichever is greater.
Normally, a fouling factor of 0.0004 h◦ Cm2/kcal for cooling water shall be considered.
A gate or butterfly valve will be provided on the water return line from each exchanger.
For flow adjustments, a globe or butterfly valve shall be installed on water supply line.
3. Nozzles