This document provides information about upgrading an existing EST3 fire alarm system to an EST4 system, including which EST3 components can be reused and which new components need to be installed. Potential reusable EST3 components include the battery distribution bus, initiating module, signature driver controller, and chassis assembly. New components that would need to be installed include the central processing unit, LCD display, ground fault detection module, enclosure, and filler plate. This is an example of upgrading a standalone EST3 system in a single story warehouse to an EST4 system while reusing the inner and outer cabinet doors.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
248 views
EST3 To EST4 Forward Migration SINGLE
This document provides information about upgrading an existing EST3 fire alarm system to an EST4 system, including which EST3 components can be reused and which new components need to be installed. Potential reusable EST3 components include the battery distribution bus, initiating module, signature driver controller, and chassis assembly. New components that would need to be installed include the central processing unit, LCD display, ground fault detection module, enclosure, and filler plate. This is an example of upgrading a standalone EST3 system in a single story warehouse to an EST4 system while reusing the inner and outer cabinet doors.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1
EST3 WITHOUT AUDIO CONTROL
UPGRADE TO EST4
EST3 Uses existing 3-CAB7B wall box with the EST4
new components listed below.
POTENTIAL REUSABLE EST3 COMPONENTS NEW COMPONENTS
Central Processing Unit
Battery Distribution Bus Initiating Module Signature Driver Controller City Tie Module 4-CPU 3-BTSEN 3-IDC8/4 3-SDDC1, 3-SSDC1 CTM 3-SDDC2, 3-SSDC2 LCD Display Chassis Assembly Display Rail Module Ground Fault Detection 4-3LCD 3-CHAS7 Tamper Switches Module 3-LDSM 3-TAMP GFD Wallbox Modem Dialer (DACT) 3-TAMPRCC 3-CAB5(R) Enclosure 3-MODCOM(P) 3-CAB7B LED Display Switches MFC-A 3-CAB14B Signal Module 3-12/S1GY, 3-12/S1RY, Filler Plate 3-CAB21B 3-OPS 3-12/S2Y, 3-12RY, 3-12SG, 3-LRM This example is a Power Supply 3-12SR, 3-24G, 3-24R, 3-24Y, Cabinet Door 3-PPS/M 3-4/3SGYWR, 3-6/3S1G2Y, standalone EST3 3-CAB7(R) 3-CAB14D(R) 4-PPS/M 3-6/3S1GYR system in a single 3-CAB21D(R) 3-BBC/M Battery Cabinet story warehouse, 3-BPS/M BC-1(R) reusing the inner and Graphic Cards Cabinet outer cabinet doors. 3-EVDVRA Coder 3-EVPWRA 3-RCC7R CDR-3 3-RCC14R 3-RCC21R
DISCLAIMER: Unique installations may cause variances.
1. Check the detailed technical migration guide, P/N 3102305-EN • REV 005 • ISS 14JAN22, to identify the earliest firmware version supported. 2. Only signature detectors are backward compatible with EST4. 3. The 3-SDU cannot be used to program an EST4 system. To program your new EST4 system, you must use the 4-CU configuration utility.