Column Location Layout: - Cadd Designer'S

The document provides specifications for concrete mix and reinforcement for a building foundation. It specifies a concrete mix of 1:1.5:3 conformity with IS 456-2000. Reinforcement will be grade Fe 415 bars conformity with IS 1786-1985. It includes a footing plan and section showing column locations and reinforcement details. Dimensions are in meters and the design is for a ground floor only.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
46 views1 page

Column Location Layout: - Cadd Designer'S

The document provides specifications for concrete mix and reinforcement for a building foundation. It specifies a concrete mix of 1:1.5:3 conformity with IS 456-2000. Reinforcement will be grade Fe 415 bars conformity with IS 1786-1985. It includes a footing plan and section showing column locations and reinforcement details. Dimensions are in meters and the design is for a ground floor only.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

* REFER RELEVANT ARCHITECTURAL DRAWING

* IS : 800, IS : 456-2000.
* CONCRETE MIX SHALL BE 1:1.5:3 FOR ALL RCC ITEMS CONFORMING TO * DO NOT COPY, RETRACE OR REPRODUCE THIS DRAWING
IS 456-2000. WITHOUT THE PERMISSION OF IOCL AUTHORITY.
* REINFORCEMENT SHALL BE HIGH STRENGTH DEFORMED BARS OF
* ALL DIMENSIONS ARE IN METERS UNLESS SPECIFIED OTHER WISE.
GRADE Fe 415 CONFORMING TO IS 1786-1985.
1 2 3 4 5 * DEVELOPMENT LENGTH OF BARS * DO NOT SCALE THIS DRAWING.
a) IN COMPRESSION 50 * LAP LENGTH SHALL BE MINIMUM OF 60 TIMES THE DIA OF BAR
a) IN TENSION 60 FOR TENSILE REINFORCEMENT.
* ROOF PROJECTION, RCC PARAPET AND RC DROP SHOULD BE
* ANY DISCREPANCY FOUND SHOULD BE BROUGHT TO THE
CASTED MONOLITHICALLY.
NOTICE OF THE ARCHITECT IMMEDIATELY.
* SBC - 160 KN/SQ.M.
* DESIGN FOR GROUND FLOOR ONLY

TYPICAL FOOTING PLAN

COLUMN LOCATION LAYOUT

TYPICAL FOOTING SECTION

NOTES:
1. CONCRETE MIX AS PER SCHEDULE
2. Y REPRESENTS TOR STEEL GRADE Fe-415.
3. CLEAR COVER TO MAIN REINF.

1 2 3 4 5 4. DESIGNED FOR GROUND FLOOR ONLY.


IN FOOTINGS - 50MM
IN COLUMNS - 40MM

SCHEDULE OF FOOTINGS SCHEDULE OF COLUMNS


TYPE OF COLUMN GROUND FLOOR MIX
COLUMNS SIZES
-4-Y16
C1 0.23x0.30 STIRRUPS Y8@200CC M20
B
-4-Y16
-2-Y12
C 0.23x0.30 STIRRUPS Y8@200CC M20

A
D - CADD DESIGNER'S
AADI GROUPS MYSURU
Ph no. 98-86-471409

E-MAIL : [email protected]
DESIGNING CONSULTANTS :-

NEW MS/HSD RETAIL OUTLET AT


FOOTING LAYOUT THADGOLU VILLAGE
PROJECT

COLUMN LOCATION LAYOUT INDIAN OIL CORPORATION LIMITED


Bangalore Divisional Office
FOOTING LAYOUT & SCHEDULE
DRAWING TITLE OWNER
(SALES BUILDING)

11 COLUMN LOCATION LAYOUT & FOOTING LAYOUT TENDER 25/12/2018 NTS

BD 110
PURPOSE
DATE

AADI
SCALE

DILEEP
BD 110
KARNATAKA. DRAWN DESIGN BY DRAWING NO.
PROJECT DETAILS