NCU NetworlControlUnit DataSheet
NCU NetworlControlUnit DataSheet
Label Description
1 Central system
6 Protection devices
7 Batteries
11 RF Power divider 2
13 RS485 Protections 4
14 Isolating transformer 5
1
Only model “NCU -…- L”.
2
Only model “NCU -…- ZB”.
3
Only model “NCU -…- ZB -…- S2”.
4
Only model “NCU -…- RS”.
5
Only model “NCU - AC2”.
4 (17)
6 5
1
3
8 2
7 11
12
6
Refer to “Model Selection Guide” at the end of this document.
5 (17)
5
3
1
7
12
2 4
6
11
9
10
14
7
Refer to “Model Selection Guide” at the end of this document.
6 (17)
10
8
Refer to “Model Selection Guide” at the end of this document.
7 (17)
2. Mechanical Characteristics
Vent
Fixing holes
Fixing holes
Vent
NCU-…-U
NCU-…-B
NCU-…-MS*-…-B
2.1 Enclosure material Polyester
2.2 Weight (kg) 9 12 17
Width 400 400
Dimensions 10
2.3 Depth 500 600
(mm)
Height 200 230
Mounting Holes quantity 4
2.4
System Diameter (mm) 5.5
Quantity 12
2.5 Cable gland
Type 2 x M25, 5 x M20, 5 x M16
Quantity 2
2.6 Protective Vent
Type M12
9
For model “NCU - AC2 -…” increase 1000 g, for model “NCU -… - L” increase 700 g.
10
Drawing information always prevails due to possible exceptions.
8 (17)
3. Environmental Characteristics
Item Value Remarks
Not designed for direct exposure to
3.1 Equipment use class Outdoor
sunlight
-20 to +60 °C NCU-…-B-S models
-20 to +40 °C NCU-…-U-S models
Ambient Operating
3.2 -40 to +60 °C NCU-…-B-L models
Temperature
-40 to +40 °C NCU-…-U-L models
Storage -20 to +25 °C
Ambient Operating 20 to 90 %
3.3
Humidity 11
Storage 10 to 95 %
3.4 Altitude, Operating 12 < 2000 m
Ingress of Solid Objects and Liquids,
IP 65 tested per IEC 61439.
The box and the cable glands IP66.
Ingress of Solid Objects and Liquids,
3.5 Degree of Protection 13
Type 4X tested per UL 508 (only for models with
“Extended UL Certification”)
External Mechanical Impacts on
IK 10
Enclosure, tested per IEC 62262:2002
Resistance to ultra-violet
3.6 IEC 62208:2011 Refer to standard.
(UV) radiation
Polyester Box and no metallic hinge. Nor
3.7 Corrosion Resistance Total14
metal parts
Sinusoidal Vibration; 10Hz @3.5mm, 10-
3.8 Vibration IEC 60068-2-6:2007
150Hz @2g, 120 min, 3 axes
5g/11ms -15g/11ms -10g/16ms
3.9 Shock IEC 60068-2-27:2009
Under no circumstance should these units be used outside the operating ranges specified in this
document. Failure to comply with these requirements may result in a fault of the power supply and void
the warranty.
11
Non-condensing.
12
Maximum operating temperature must be reduced by 5ºC per 1000 meters above specified altitude.
13
Only valid when installed according to instructions, and with all external cables and protective caps attached.
14
Only visual degradation on the color of the gold part of the antenna connector.
9 (17)
4. Electrical Characteristics
4.1 General
NCU-AC1
NCU-AC2-…-S NCU-AC2-…-L
NCU-AC3
Quantity 1
Type Single phase
Equipment Input voltage 277 VAC
4.2.1 N/A
transformer Output voltage 240 VAC
Power 100 VA 350 VA
Rated Frequency (f) 50/60 Hz
NCU-AC1-…-U
NCU-AC1-…-B NCU-AC3-…-U
NCU-AC2-…-U
Quantity 1
Type of Residual Current A type
Residual Rated Residual Current 30 mA
4.3.1 Current Circuit Rated Current (In) 63 A N/A
Breaker Number of Poles 2
Rated Voltage (Ur) 230 V
Rated Frequency (f) 50...60 Hz
Quantity 1
Number of Poles 2 1
Miniature Current Rating 6A
4.3.2
Circuit Breaker Tripping Characteristics Type C
Rated Voltage 400 VAC 277 VAC
Breaking Capacity 6 kA 10 kA
Quantity 1
Number of Poles 1
Supplementary Current Rating 2A
4.3.3 N/A
Protector Tripping Characteristics Type C
Rated Voltage 48 VDC
Breaking Capacity 10 kA
15
According to the correlation between input voltage and surge arrester protection devices.
16
For NCU -…-L Touch-Safe PTC Fan Heater input power 250W needs to be added.
10 (17)
NCU-AC1-…-U
NCU-AC1-…-B NCU-AC3-…-U
NCU-AC2-…-U
Quantity 2 1
Number of Poles 1 Modular TN
SPD according to EN
61643-11 / IEC 61643- type 2 / class II
4.3.4 Surge arrester 11
Max. continuous
operating voltage 320 V 275 V 150 V
(a.c.) (UC)
Nominal discharge
5kA 20kA
current (8/20 µs) (In)
4.5 Battery
NCU -…- B NCU -…- U
4.5.1 Battery Type Backup
4.5.2 Number of units 2 1
4.5.3 Case ABS Battery module
4.5.4 Battery Chemistry Valve regulated Lead Acid with AGM
4.5.5 Battery Capacity, nominal 1300 mAh 1200 mAh
4.5.6 Dimensions [LxWxH] 97x48x52 mm 126.6x55x153 mm
4.5.7 Battery Autonomy, typical ~ 1 hour
4.5.8 Electrical fixing configuration Faston Cage clamp
Batteries
The batteries inside the NCU, are backup batteries, that need to be replaced every two years, or if
making the annual maintenance test you detect that the battery doesn’t charge, or you detect any
damage on it.
17
Acc. to IEEE Std. 519 - requires THD < 5% and largest harmonic < 3% of fundamental.
11 (17)
Do not substitute any internal components unless specific permission from Suntrack by P4Q.
Any component change can cause the loss of the certification or the warranty of the product.
12 (17)
5.1 Wired
Item Value Remarks
Multidrop with line terminations.
5.1.1 Interface RS-485
Shielded, twisted-pair cable.
5.1.2 Protocol Modbus RTU
5.1.3 Encryption N/A
Cable requirements:
- Characteristic Imp. 100-120 ohm
- Conductor DC Res. < 90 ohm/km
5.1.4 Bus cable length 18 < 1200 m
- Shield DC Res. < 10 ohm/km
- Mutual Cap. < 45 pF/m
- Ground Cap. < 67 pF/m
5.1.5 Stub cable length <1m Branches are as short as possible.
5.1.6 Data Rate 19.2 kbps
Maximum number of slaves connected
5.1.7 Number of devices Up to 120 per gateway RS485 port without
repeater.
5.2 Wireless
Item Value Remarks
5.2.1 Interface ISM 2.4 GHz
5.2.2 Protocol Modbus over ZigBee
5.2.3 Encryption AES-128
Maximum line-of-sight distance (ideal
1200 m
laboratory conditions, no obstacles)
Typical maximum distance between
5.2.4 Signal range 19 90 to 150 m
TCUs in North/South direction
Typical maximum number of TCUs to
20 to 50 units
the East and to the West of the NCU
Estimation of effective speed –
5.2.5 Data Throughput 10.0 kbps depends on installation, environment,
etc
5.1.6 Number of devices 20 Up to 100 Maximum number of slaves connected.
18
Reduced by the installation quality.
19
Typical values for single-row PV tracker field environments – strongly dependent on tracker design, antenna
installation, surrounding structures and terrain, interference sources, etc. Contact P4Q for site layout assessment.
20
This number will be highly influenced by the layout of the plant. it is recommended to consult P4Q for the
reliability of communications.
13 (17)
6. Control
21
Depend on the number of TCUs and net encryption
22
Is needed between 3 to 5Mbps of internet connection
14 (17)
7. Standards Compliance
Standard Remarks
IEC 61439-1:2020, IEC 61439-2:2020 Low-voltage switchgear and control gear assemblies
Safety Precautions for Transport of Dangerous Goods -
UN 2800
Lithium Batteries 23
Standard Remarks
UL 508A: 2018 Ed.3 (CDR Report) Safety Standard for Industrial Control Devices
C22.2 No.286 Industrial Control Devices
UL508 Safety Standard for Lead Acid Battery
23
Classified as “UN 2800, Lead Acid Batteries contained in the NCU” – for transportation, this unit must be properly
packaged, labelled and registered on “Shipper’s BATTERIES, WET, NON- SPILLABLE, electric storage”, IATA A 67.
24
ETL listing control number 5010116. For units manufactured in US only.
15 (17)
SUPPLY INPUT
AC1 AC-Powered, 1-ph, 100-240Vac
AC2 AC-Powered, 1-ph, 277Vac 25
AC3 AC-Powered, 1-ph, 120Vac 26
SWITCH TYPE
ETS Un-managed Standard ethernet 5 ports
ETX Un-managed Extended ethernet 8 ports (+RJ45)
FP1 Un-managed 4x Ethernet, 1x Fiber port Single-Mode SC
FP2 Un-managed 4x Ethernet, 1x Fiber port Multi-Mode SC
FP3 Un-managed 4x Ethernet, 1x Fiber port Single-Mode ST
FP4 Un-managed 4x Ethernet, 1x Fiber port Multi- Mode ST
FP5 Un-managed 7x Ethernet, 1x Fiber port Single-Mode SC
FP6 Un-managed 7x Ethernet, 1x Fiber port Multi-Mode SC
FP7 Un-managed 7x Ethernet, 1x Fiber port Single-Mode ST
FP8 Un-managed 7x Ethernet, 1x Fiber port Multi- Mode ST
FP9 Un-managed 4x Ethernet, 2x Fiber port Single-Mode SC
MSA Managed 3x Ethernet port, 2 x Fiber port Single-Mode SC
Redundancy protocols:RSTP, STP, Turbo Chain, Turbo Ring v1/v2
MSB Managed 3x Ethernet port, 2 x Fiber Multi-Mode SC
Redundancy protocols:RSTP, STP, Turbo Chain, Turbo Ring v1/v2
FIELD COMMUNICATION
ZB ZigBee (wireless)
RS RS485 (wired)
GATEWAY TYPE
GW2 2 x Gateway ZigBee
GW3 Gateway RS485 2 ports
GW4 Gateway RS485 4 ports
STANDARDS COMPLIANCE
B Basic Certifications
U Extended UL Certifications
TEMPERATURE RANGE
S Standard Temperature
L Extended Low Temperature
EXPANDED SENSORS
blank Not sensors connected to the NCU
S1 Wind (RS485/RS485-Ultrasonic)
S2 Snow + Wind (RS485/RS485-Ultrasonic)
OPTIONS
blank N/A (Standard Model)
zzz Custom Variant 27
25
Only UL Standard models.
26
Only UL Standard models.
27
Contact P4Q for details on custom variants.
16 (17)
9. Typical Applications
• ZigBee
• RS485
17 (17)
Revision History