Trumen TLC Data Sheet
Trumen TLC Data Sheet
TLC2
®
Capacitance Type
Level Transmitter sensing matters
Product Overview
Trumen two wire capacitance type level transmitter model TLC2 is
suitable for liquid & solid application like powder, slurry, chemical,
edible oil etc. Trumen TLC2 is a fully, partially PTFE & ceramic
insulated and used as a robust rod probe and flexible rope probe for
level detection.
Operating Principle
The probe forms a capacitance with the
metalic tank-wall. The capacitance is total
C(residual) sum of three capacitance:-
C(air)=ε(air) x P x (H-L)
C(material)=ε(material) x P x L
C(residual) is due to device itself.
C(material)
Where ε(air) is the dielectric constant of air ≈1.
ε(material) is dielectric constant of material.
P is the constant of probe and installation,
H is the active length of probe and L is the
level of material.
C(high) C(low)
L(high) L(low) =
P x {ε(material) ε(air)}
Applications mA L(high)
4 20
Capacitance level transmitter probe is used in different
Level
L(low)
applications like CALIB
read C(high) 4 20
- Oil - Chemical for 20mA
mili-Ampere
- Water - WTP
device creates a chart of level to 4-20mA
- WFI - STP
translation.
- DM/DI water - Cement
- Corrosive liquids - Steel
- Wheat flour - Food & Beverages Features
- Rice paddy - Diesel
- Granuels Compact size
Fast response time
Easy Calibration Compensation against material build-up
Easy calibration via DIP switch
Suitable for top mounting
Just fill to 100%
Fluid Turbulation Stability
and teach, just fill
4-20mA isolated output or 1-5V & 2-10V output
to 0% and teach,
calibration done. Ingress protection: IP 67/68 (as per IS/IEC 60529:2001)
Process temperature max 300°C
1 2 3 4 5 100% Process pressure max. 20 bar
ON
Performance Specifications
Features
Parameter Description
General
Min. Dielectric Constant 1.8 (non-hygroscopic)
Maximum measured error Max. ±1 mm (at reference operating conditions)
Repeatability 1 mm
Accuracy ±1%
Hysteresis Approx. 2 mm
Influence of medium Max +2 to -3 mm (-20 to +150 °C)
temperature
Influence of medium pressure Max 0 to -3 mm (-1 to 20 bar)
ICT to TLC cable Shileded 2 Core PVC cable with 1 to 1.5 mm2 conductors cross section
Process
Ambient Temperature -20°C ... 70°C (-4°F ... 158 °F)
Process Temperature -20°C ... 100°C (-4°F ... 212 °F)
Extended Process Temperature PTFE Insulation: -30°C ... 250°C (-22 °F ... 482 °F), *Ceramic Insulation: -30°C ... 300°C (-22°F ... 572°F),
(extensions & heat sinks required)
(*Note- Ceramic part insulation probe suitable for non-conductive or low dielectric material only)
Process Pressure absolute / max. 20 bar (for ceramic insulation : 1 atm)
Physical Specifications
Wetted Parts SS 304, SS 316, SS 316L, PTFE, Part Ceramic
Process Connections NPT / BSP 1", 1-1⁄4", 1-1⁄2", 2" & TC 1-1/2", 2" & Flanged ANSI / JIS / DIN / ASA / custom
Probe Insertion Length Rigid Rod Probe: 50mm to 3,000mm, Flexible Rope Probe: 100mm to 20,000mm
Typical Installation
inactive length
(ground)
PTFE insulated/bare rope
active length
(sensitive)
../qrd/tlc2-qrd-p2-160721.svg
TLC2: Capacitance Type Level Transmitter sensing matters
®
Performance Specifications
Features Specifications
Parameter Description Electrical Connection
Electrical
EIL Integral Electronics Two-wire Loop Powered TLC2
15 to 60 VDC
Interface/Output ModBus-RTU / complementry 0-5V output suitable for >20K Ohm U 10 to 30 VDC 0-5V 4-20mA ModBus
over
x A B GND RS485
Calibration/configuration available through ModBus as well as
without using DIP switches DC Supply
min. 10V
max. 30V
TLC2
EIV Integral Electronics three wire system
Supply 15-60 VDC increase
DC Supply
min. 15V Not used
max. 60V
TLC2-SS
EIR Blind Integral Electronics suitable for Trumen ICT series Remote turn-on
to add
ICT: Indicator
1 2 3 4 5 6 7 8 9
To Sensor
18 19
Specifications ICT provides numerical LED indicator, control logic with relay ICT2
Indicator Controller Transmitter
output & 24VDC Transmitter power supply F1 Rly1 Rly2 Rly3 Rly4 Func. Down TLC2-SS
turn-on
to add
status the range
2200pF
F2 Enter from ICT indicator
1000pF
470pF
220pF
U 18 19
Range depends on probe length and
conductivity and dielectric constant.
Power Supply SA : 80-260VAC, 50/60Hz for AC version Trumen Technologies Pvt. Ltd.
Email: [email protected], Web: www.trumen.in
ICT: Indicator 1 2 3 4 5 6 7 8 9
To Sensor
18 19
Sensor2
80 to 260 Isolated
Sensor
Sensor
50/60 Hz
RKx Relay Rating Contactors with 2NO/2NC rated at (1, 2 or 3 contactors, only in For DC supply connection
IP40 metal sheet enclosure)
ICT2
Indicator Controller Transmitter
Transmitter Power Supply Isolated loop supply 24V +/- 4V Suitable for maximum 25mA load Menu Up
Re-Transmission 4-20mA, Error@21mA, galvanically isolated loop powered section Trumen Technologies Pvt. Ltd.
Email: [email protected], Web: www.trumen.in
ICT: Indicator
12 345 6 78 9
conductivity and dielectric constant.
To Sensor
18 19
for use with either integrated ICT Isolated Loop Supply or any 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
NC P NO NC P NO X X X X X X Always connect "Earth"
Common
DC Earth Active
Sensor1
Sensor2
Sensor
Sensor
Supply 4-20mA
Test
18...32V Output
Ordering Information
Features