Hand Pumps Type PM: 2-Plunger
Hand Pumps Type PM: 2-Plunger
1 MODEL CODE
PM - 106 ** /*
Synthetic fluids:
/WG = water-glycol
2-plunger
/PE = phosphate ester
hand pump
2 OPERATING CHARACTERISTICS with hydraulic fluid having a viscosity of 24 mm²/s and 40°C
Displacement for
Max pressure Shaft rotation angle Maximum torque required
Model double stroke
[bar] [degree] [Nm]
[cm³]
PM-106 6 500 ± 35° 139
A200
3 MAIN CHARACTERISTICS OF HAND PUMP TYPE PM
Installation position Vertical position, with inlet port facing upward to ensure complete case filling
Commissioning Pumping operation is made by alternative movement of the lever after closing by-pass valve.
Note: the by-pass valve connects the delivery ports with inlet port and when locked it could allow some
leakage from outlet ports.
Two opposite outlet ports are available for pump delivery: one of these is supplied plugged.
The pumps are supplied without lever harm that could made by a simple tube with Ø 18 mm inside
diameter. Usually a lenght of 500 to 600 mm is appropriate.
Lever position can be selected by proper assembling of lever on splined shaft.
4 DIMENSIONS [mm]
IN
By-pass valve
OUT OUT
(completely open)
Mass: 4,6 Kg
05/00