0% found this document useful (0 votes)
28 views

Kappler Tech Data

This document provides technical data and testing details for various chemical protective materials, including Zytron, Frontline, and ChemTape brands. It includes results from ASTM F1001 chemical testing of 17 chemicals' effects on the materials' protective properties. It also lists breakthrough time criteria results from testing the materials' effectiveness against 4 chemical warfare agents (HD, GB, L, and VX). All tests were performed by independent laboratories under controlled laboratory conditions, not actual use.

Uploaded by

towfiq.scc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
28 views

Kappler Tech Data

This document provides technical data and testing details for various chemical protective materials, including Zytron, Frontline, and ChemTape brands. It includes results from ASTM F1001 chemical testing of 17 chemicals' effects on the materials' protective properties. It also lists breakthrough time criteria results from testing the materials' effectiveness against 4 chemical warfare agents (HD, GB, L, and VX). All tests were performed by independent laboratories under controlled laboratory conditions, not actual use.

Uploaded by

towfiq.scc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Technical Data

And Testing Details

ASTM F1001 Chemical Test Battery*


CHEMICAL Zytron® Frontline® ChemTape®
100 100XP 200 300 400 500 300 500
Acetone NT NT 17 >480 >480 >480 >480 >480 >480
Acetonitrile NT NT 52 87 >480 >480 >480 >480 >480
Carbon Disulfide NT NT 2 >480 >480 >480 >480 >480 >480
Dichloromethane NT NT 2 70 88 >480 10 253 >480
Diethylamine NT NT 21 >480 >480 >480 >480 >480 160
Dimethylformamide NT NT 77 >480 >480 >480 >480 >480 >480
Ethyl Acetate NT NT 14 >480 >480 >480 >480 >480 >480
n-Hexane NT NT 7 >480 >480 >480 >480 >480 >480
Methyl Alcohol NT NT >480 55 >480 >480 >480 >480 >480
Nitrobenzene NT NT 97 >480 >480 >480 >480 >480 >480
Sodium Hydroxide >480 >480 >480 >480 >480 >480 >480 >480 >480
Sulfuric Acid >480 >480 >480 >480 >480 >480 >480 >480 >480
Tetrachloroethylene NT NT 21 >480 >480 >480 >480 >480 >480
Tetrahydrofuran NT NT 3 >480 >480 >480 >480 >480 >480
Toluene NT NT 6 >480 >480 >480 >480 >480 >480
GASES
Ammonia Gas NT NT NT 39 NT >480 >480 >480 NT
1,3 Butadiene NT NT NT >480 NT >480 >480 >480 NT
Chlorine Gas NT NT NT >480 NT >480 >480 >480 NT
Ethylene Oxide Gas NT NT NT 81 305 >480 >480 >480 NT
Hydrogen Chloride Gas NT NT NT >480 NT >480 NT >480 NT
Methyl Chloride Gas NT NT NT >480 NT >480 NT >480 NT

Chemical Warfare Agent Data**


Zytron®300 Zytron®500 Frontline®500 ChemTape®
CHEMICAL AGENT Breakthrough Breakthrough Breakthrough Breakthrough
Time Criteria Time Criteria Time Criteria Time Criteria
Bis (2-chloroethyl) sulfide
>480 4.0 ug/cm2 >480 4.0 ug/cm2 >480 4.0 ug/cm2 >480 4.0 ug/cm2
(Mustard:HD)
Isopropyl methylfluorophosphonate
>480 1.25 ug/cm2 >480 1.25 ug/cm2 >480 1.25 ug/cm2 >480 1.25 ug/cm2
(Sarin:GB)
Chlorovinyl arsinedichloride
>240 4.0 ug/cm2 >480 4.0 ug/cm2 >240 4.0 ug/cm2 NT NT
(Lewisite:L)
O-ethyl S-(2-diisopropylaminoethyl)
>480 1.25 ug/cm2 >480 1.25 ug/cm2 >480 1.25 ug/cm2 >480 1.25 ug/cm2
methylphosphonothiolate (Nerve:VX)

* Industrial chemical testing was conducted in accordance with ASTM F 739 with normalized breakthrough times reported in minutes.
** C
 hemical Warfare Agent testing was conducted in accordance with MIL-STD-282 and/or NFPA 1994-2001 with breakthrough times reported based on
total cumulative permeation.
Note: Sources for all chemical test data are independent laboratories. All tests were performed under laboratory conditions and not under
actual use conditions. Tests were performed on material samples, not actual garments.

Kappler, Know What You’re Getting Into, ProVent, Zytron, Frontline, ChemTape, HazMatch, 2N1, and ChemScan are trademarks of Kappler, Inc. AquaSeal is a trademark of YKK.
Responder, Reflector, Pro/Shield, NexGen, SuitSmart and CPF are trademarks of E. I. du Pont de Nemours and Company. HazProof is a trademark of Tingley Rubber.

You might also like