0% found this document useful (0 votes)
145 views

SGC6

Uploaded by

JAY ROD AWIT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
145 views

SGC6

Uploaded by

JAY ROD AWIT
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Standalone Gas Controller

Specifications subject to change without notice. | USA 230124 | Page 1 of 6

DESCRIPTION
Wall-mounted, NEMA 4X standalone ventilation
PolyGard®2
controller with one, two, or three high-performance SGC6
SC2-Series gas sensor modules.
Intuitive, menu-driven setup allows on/off, multi-speed,
and variable speed control of ventilation equipment in
response to user-specified gas concentration levels.
Multi-color LCD and standard horn/light module for
local annunciation of escalating alarm levels.
Conforming to Safety Integrity Level 2 (SIL 2) and
rigorous international standard EN 50545-1 for parking
garages and tunnels, PolyGard®2 monitoring and
control systems utilize advanced self-diagnostics and
flexible ventilation control functions to ensure maximum
human safety without compromising energy efficiency.
Advanced, microprocessor-based X-Change sensor
modules meet or exceed the EN 50545-1 self-
diagnostic standards including notifying the controller
when calibration is due. Although field calibration is
EMC Directives 2014/30/EU
possible, X-Change technology allows fast and cost-
effective sensor module swaps minimizing field service LVD 2014/35/EU
time, eliminating system downtime and ensuring peak CE
system performance for many years. EN 61010-1:2010
EN 50271
APPLICATION
ANSI/UL 61010-1
To detect and control levels of toxic and combustible CAN/CSA-C22.2 No. 61010-1
gases in a wide variety of commercial applications
such as carbon monoxide and nitrogen dioxide levels
in parking structures, package sorting hubs, vehicle
repair shops, tunnels, and equipment rooms. Although
typically operating as a standalone controller directly
activating ventilation equipment in response to rising
gas levels, the SGC6 can also work in conjunction
with building management systems via Modbus
serial communications, analog (gas value) or binary
(threshold / relay) output signals.

FEATURES
• 1 or 2 on-board SC2-Series gas sensor modules • Menu-driven controller setup
• Optional 3rd gas sensor input with DR6 Digital • X-Change sensor technology for low-cost life cycle
Remote sensor maintenance
• 2-Line, 16-character LCD display with dual color • Digital measurement processing with temperature
background compensation
• Two (2) SPDT alarm relays, 30 VAC/VDC, 0.5 A • Internal diagnostics including integrated hardware
• One (1) 4-20mA analog output watchdog
• Audible / visual alarm annunciation • High-impact polycarbonate enclosure, NEMA 4X
• RS-485 serial communications to DGC6-Series (IP65)
Digital Gas Controllers or other Modbus controllers • Software conforms to SIL 2 standard
• 24 VAC/VDC powered

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
SGC6
Specifications subject to change without notice. | USA 230124 | Page 2 of 6

SPECIFICATIONS
Electrical Serial interface
Power supply 24 VDC ±20%, - local bus plug connector / 19200 Baud
reverse polarity protected; - field bus RS-485 / 19200 Baud
24 VAC -10%/+15%, - tool bus 2-wire / 19200 Baud
VAC allowed for standalone Physical
configuration only Enclosure “C”, standard
Power consumption 24 VDC - material Polycarbonate,
- base (with LCD) 80 mA UL94 V-2, fire retardant
- sensors See SC2 datasheet - color Light gray
- horn & multi-status LED 5 mA - protection NEMA 4X (IP65)
- analog output 22 mA - installation Wall (surface) mounted,
Alarm relays Two (2), 30 VAC/VDC, 0.5 A, or single gang electrical box
potential‑free, contacts (SPDT) Dimensions (H x W x D)
Analog input One (1), 4-20 mA overload - base unit 5.12 x 5.12 x 2.95 in
and short-circuit proof, (130 x 130 x 75 mm)
input resistance 200 Ω Cable entry, knock outs 3 holes for 1/2 in. conduit,
Analog output signal One (1), proportional, closed with silver “plugs”
overload and short-circuit proof, Wire connection
load ≤ 500 Ω - local bus (SC2) 3-pin removable connector
4-20 mA = measuring range; - remote sensor (DR6) 3-wire, max. length 16.4 ft (5 m)
3.0 < 4 mA = under range; - analog output Screw-type terminal;
> 20-21.2 mA = over range; 24 AWG (0.25 mm2), min.
2.0 mA = fault 16 AWG (1.3 mm2), max.
Output for local bus 5 VDC, 250 mA max. - power supply, relays Screw-type terminal;
Overload, short-circuit and 24 AWG (0.25 mm2), min.
polarity protected 14 AWG (2.5 mm2), max.
Output signal for Weight 1.32 lb (0.6 kg)
serial communication Digital, RS-485, Conforms to EMC Directive 2014/30/EU
Modbus-RTU and LVD 2014/35/EU
DGC6 protocol, CE
19200 baud EN 50271
Sensors SC2 Series EN 61010-1:2010
- performance See SC2 datasheet for specific Certified to ANSI/UL 61010-1
gases CAN/CSA-C22.2 No. 61010-1
- coverage See SC2 datasheet for specific Warranty Two years material and
gases workmanship,
- storage time 6 months (for sensor elements) 12 months normal exposure for
Environmental sensor element
Permissible ambient See SC2 datasheet for specific
gases
Horn & Status LED Configurable by local thresholds
DEFAULT SETTINGS
or remote DGC6 parameters
Horn Trip/Setpoints
- acoustic pressure > 85 dB (A) (dist. 0.1 m / 0.3 ft) Carbon Monoxide (CO)
- frequency 2300 Hz - stage 1 25 ppm
- protection class NEMA 4X (IP65) - stage 2 150 ppm
Status LED - stage 3 150 ppm
- color / mode Red = Alarm; - stage 4 150 ppm
Yellow = Fault; - hysteresis 10 ppm
Green = Power (Normal); Nitrogen Dioxide (NO2)
Green (flashing) = Service - stage 1 2 ppm
- protection class NEMA 4X (IP65) - stage 2 5 ppm
Liquid Crystal Display - stage 3 5 ppm
LCD Two lines, 16 characters each, - stage 4 5 ppm
illuminated - hysteresis 0.5 ppm

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
SGC6
Specifications subject to change without notice. | USA 230124 | Page 3 of 6

ACCESSORIES
Duct Mounting Kit PG2-DUCTKIT
- flow rate Min. 3.1 mph (5000 m/h),
max. 12.4 mph (20,000 m/h)
- air duct diameter Min. 3.94 in. (0.1 m),
max. 39.37 in. (1.0 m)
- length of sampling tube 9.84 in. (250 mm), adaptable
- hose length 2 x 39.37 in. (1000 mm)
Calibration Kits
- carbon monoxide CALKIT-PG2-CO
Sensor calibration adapter
w/ tube and cup, 500 mL/min.
regulator, 17L 200 ppm carbon
monoxide, 17L 99.99% nitrogen,
carrying case
- combustible gases CALKIT-PG2-COMB
Sensor calibration adapter
w/ tube and cup, 150 mL/min.
regulator, 17L 2.5% methane,
17L 99.99% nitrogen,
carrying case
- nitrogen dioxide CALKIT-PG2-NO2
Sensor calibration adapter
w/ tube and cup, 500 mL/min.
regulator (stainless steel),
70L 10 ppm nitrogen dioxide,
70L 99.99% nitrogen,
carrying case
- carbon monoxide CALKIT-PG2-CO-NO2
& nitrogen dioxide Sensor calibration adapter
w/ tube and cup, 500 mL/min.
regulator (for CO), 500 mL/
min. regulator (stainless steel,
for NO2), 17L 200 ppm carbon
monoxide, 70L 99.99% nitrogen,
70L 10 ppm nitrogen dioxide,
and (2) carrying cases

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
SGC6
Specifications subject to change without notice. | USA 230124 | Page 4 of 6

DIMENSIONS
inches (mm)

1.30 0.91
(33) (23)

0.94
(24)

5.12 5.12 0.94 1.26


(130) (130)
6.22 (24) (32)
(158)

(7 95
2.
5)
5.12
(130)
5.12
(130)

WIRING CONFIGURATION
SGC6 Connections
Relays drawn de-energized.
Relay Mode = Energized (Alarm ON = Relay OFF)
Alarm Alarm
Relay 1 Relay 3

X5 1 2 3 X6 1 2 3
4 F_Bus_B
Service Tool
Field Bus

3 F_Bus_A
2 0 VDC/VAC*
1 24 VDC/VAC*
X4
* VAC allowed for standalone configuration only

Jumper Local Bus_3 Analog


J5 Reset (X7) Output
(Reserved)
open: 4-20 mA (default)
+5 VDC

close: 2-10 V
AO_01
0 VDC
L_Bus

GND

Local Bus_2 Local Bus_1


(X2) (X3)
X8 1 2 3 1 2 3 4 5
X7

X1

(Reserved)

Remote Sensor
4-20 mA
GND

SC2 SC2 16.4 ft (5 m), max.


Sensor 2* Sensor 1*

* SC2/DR6 Sensor Cartridges


available separately

DR6

1 +5 VDC
2 0 VDC
3 L_Bus
X7
SC2
Sensor 3*

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
SGC6
Specifications subject to change without notice. | USA 230124 | Page 5 of 6

SENSOR BOARD COMPONENTS


SGC6

JP5 5 GND 1
Relay 3 R3
open: 4-20 mA 4 AO_01 2
close: 2-10 V X6
3 3
3 2 R1
2 1
1 Relay 1
1 X5 2 4
X1
Local Bus_3 3
X7 Reset 3
(reserved)
LED Field Bus 2
WAO
(Horn/LED X4
Relay 2) 1
Local Bus_1
X8 Local Bus_2 X3
X2

JP4 Service Tool Port / JP3


LCD Connector JP2
X9 JP1

FIELD WIRING CONFIGURATION


The SGC6 is a fully capable standalone controller. In specific
applications where interfacing to the DGC6 (PG2 Gas Detection
System) is required, observe the following wiring connections.

F_Bus_B
Field Bus

F_Bus_A
0 VDC
24 VDC

4 F_Bus_B SGC6
3 F_Bus_A
2 0 VDC
1 24 VDC
SGC6
X4 F_Bus_B 4
Last Device on Trunk Segment
F_Bus_A 3
If this SGC6 is the last
2 device on a PG2 trunk
segment, use a 560 Ω
1
resistor at terminal X4
X4 pins 4 and 3.

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com
SGC6
Specifications subject to change without notice. | USA 230124 | Page 6 of 6

ORDERING INFORMATION Gas Sensor & Range


Mounting
PART NUMBER DESCRIPTION # TOXIC GASES AND OXYGEN Height (ft)
BUNDLED SENSORS AND CONTROLS E1110-E Carbon Monoxide CO 0-250 ppm 5-6

SGC6-02-CO SGC6, DGC6 Protocol, E1110-F Carbon Monoxide CO 0-300 ppm 5-6

(1) 0-250 ppm CO sensor E1130-A Nitrogen Dioxide NO2 0-10 ppm 5-6
E1130-B Nitrogen Dioxide NO2 0-20 ppm 5-6
SGC6-02-CO-CO SGC6, DGC6 Protocol,
E1130-C Nitrogen Dioxide NO2 0-30 ppm 5-6
(2) 0-250 ppm CO sensors
E1130-D Nitrogen Dioxide NO2 0-500 ppm 5-6
SGC6-02-CO-NO2 SGC6, DGC6 Protocol, E1125-C Ammonia NH3 0-300 ppm Ceiling
(1) 0-250 ppm CO sensor, E1125-D Ammonia NH3 0-1000 ppm Ceiling
(1) 0-20 ppm NO2 sensor E1193-C Chlorine Cl2 0-10 ppm Floor
SENSOR PLATFORM E1183-C Hydrogen Cyanide HCN 0-100 ppm Ceiling
E1189-C Ethylene C 2H 4 0-200 ppm 5-6
SGC6-02 Standalone gas controller,
E1185-B Formaldehyde CH2O 0-10 ppm Floor
remote relay and AO module,
E1190-A Ozone O3 0-5 ppm Floor
DGC6 Protocol;
E1196-B Sulfur Dioxide SO2 0-20 ppm Floor
up to (3) sensor inputs capable;
E1197-A Hydrogen Sulfide H 2S 0-50 ppm Floor
2-line, 16-char LCD display;
E1195-A Oxygen O2 0-25 Vol% 5-6
(2) SPDT relays; Mounting
(1) 4-20 mA analog output; # INFRARED SENSORS Height (ft)
horn & status LED; I1164-B Carbon Dioxide CO2 0-5 Vol% 5-6
includes “C” enclosure; I1164-C Carbon Dioxide CO2 0-2 Vol% 5-6
sensor cartridges ordered # COMBUSTIBLE GASES
Mounting
Height (ft)
separately P3485-A Acetone C 3H 6O 0-100% LEL Floor
P3408-A Ammonia NH3 0-100% LEL Ceiling
P3496-A Gasoline Vapors - 0-100% LEL -
P3460-A Butane C4H10 0-100% LEL Floor
P3472-A Cyclopentane C5H10 0-100% LEL Floor
P3427-A Ethyl Acetate C4H8O2 0-100% LEL Floor
P3425-A Ethyl Alcohol C2H5OH 0-100% LEL Floor
SC2 Sensor Cartridges available separately. P3410-A Ethylene C 2H 4 0-100% LEL Ceiling
See SC2 datasheet for specifications. P3491-A Heptane C7H16 0-100% LEL Floor
P3435-A Hexane C6H14 0-100% LEL Floor
The SGC6 accepts up to (2) SC2 Sensor P3476-A Isopentane C5H12 0-100% LEL Floor
Cartridges simultaneously. P3482-A Isopropyl Alcohol C 3H 8O 0-100% LEL Floor
P3498-A JP8 - 0-100% LEL -
In a 2-sensor configuration, both sensor
modules must have the same mounting height P3402-A LPG - 0-100% LEL -
requirements. P3400-A Methane CH4 0-100% LEL Ceiling
P3450-A Methanol CH3OH 0-100% LEL Floor
A 3-sensor configuration is possible with a P3458-A Methyl Ethyl Ketone C 4H 8O 0-100% LEL Floor
remote DR6. The max. distance allowed P3475-A Pentane C5H12 0-100% LEL Floor
between the SGC6 and DR6 is 16.4 ft (5 m). P3480-A Propane C 3H 8 0-100% LEL Floor
P3480-C Propane C 3H 8 0-5000 ppm Floor
P3484-A Propyl Alcohol C 3H 8O 0-100% LEL Floor
P3490-A Toluene C 7H 8 0-100% LEL Floor
P3440-A Hydrogen H2 0-100% LEL Ceiling

ACCESSORIES
PG2-DUCTKIT (1) Duct mounting kit for SC2 / AT6 sensor
CALKIT-PG2-CO Carbon monoxide calibration kit for
SC2 / AT6 sensors
CALKIT-PG2-COMB Combustible calibration kit for
SC2 / AT6 sensors
CALKIT-PG2-NO2 Nitrogen dioxide calibration kit for
SC2 / AT6 sensors
CALKIT-PG2-CO-NO2 CO & NO2 calibration kit for SC2 / AT6 sensors

INTEC Controls | 12700 Stowe Drive, Suite 100, Poway, CA 92064 | Ph: (858) 578.7887 & (888) GO.INTEC | inteccontrols.com

You might also like