East 4
East 4
Max Fz 4 344 OPERATING (D+L+WINDNORTH)STR 0.561 34.364 4.826 10.226 -0.12 1.297
Min Fz 4 346 OPERATING (D+L+WINDSOUTH)STR 0.561 34.364 -4.826 -10.226 0.12 1.297
Max Mx 4 344 OPERATING (D+L+WINDNORTH)STR 0.561 34.364 4.826 10.226 -0.12 1.297
Min Mx 4 346 OPERATING (D+L+WINDSOUTH)STR 0.561 34.364 -4.826 -10.226 0.12 1.297
Max My 4 346 OPERATING (D+L+WINDSOUTH)STR 0.561 34.364 -4.826 -10.226 0.12 1.297
Min My 4 344 OPERATING (D+L+WINDNORTH)STR 0.561 34.364 4.826 10.226 -0.12 1.297
Max Mz 1 353 OPERATING (D+L+WINDEAST) STR -5.117 5.846 0 0 0 7.821
Min Mz 4 383 OPERATING (D+WINDW)STR/STB 6.55 22.081 0 0 0 -6.681
Horizontal Vertical Horizontal Moment
Node L/C Fx kN Fy kN Fz kN Mx kNm My kNm Mz kNm
Max Fx 4 351 OPER 6.696 30.991 0 0 0 -6.345
Min Fx 1 353 OPER -5.117 5.846 0 0 0 7.821
Max Fy 4 353 OPER -3.032 37.382 0 0 0 6.712
Min Fy 1 385 OPER -4.971 3.548 0 0 0 7.35
Max Fz 4 344 OPER 0.561 34.364 4.826 10.226 -0.12 1.297
Min Fz 4 346 OPER 0.561 34.364 -4.826 -10.226 0.12 1.297
Max Mx 4 344 OPER 0.561 34.364 4.826 10.226 -0.12 1.297
Min Mx 4 346 OPER 0.561 34.364 -4.826 -10.226 0.12 1.297
Max My 4 346 OPER 0.561 34.364 -4.826 -10.226 0.12 1.297
Min My 4 344 OPER 0.561 34.364 4.826 10.226 -0.12 1.297
Max Mz 1 353 OPER -5.117 5.846 0 0 0 7.821
Min Mz 4 383 OPER 6.55 22.081 0 0 0 -6.681
A 3+7
CALCULATION SHEET
Office
Mumbai Page No. Cont'n page No.
H B
h= 150 mm
b= 90 mm
tf = 12 mm
tw = 6.5 mm
bb = 180 mm
tp = 15 mm
c = 50 mm
Anchors M 16 A - 4.6
Spacing of ha = 0 mm
anchors ba = 180 mm
Fsd.H = 1.3 KN
Mx = 0 KNm
Mz = 0 KNm
Z= 0.5Z1 + ZT = 69 mm
Z1 = 150- 12 = 138 mm
ZT = 0/2 = 0 mm
Ned/2+M/z1 = 16.8 KN
A 4+7
CALCULATION SHEET
Office
Mumbai Page No. Cont'n page No.
Min.
Axial
Comp.+
Moment
(For Anchor bolt design) Fsd.v = Ned = -2.4 KN
Fsd.H = 1.6 KN
Mx = 0 KNm
Mz = 0 KNm
Resultant M = Sqrt(Mx + Mz ) =
2 2
0 KNm
αcc is the coefficient taking account of long term effects on the compressive strength and
Note: The value of αcc for use in a Country should lie between 0,8 and 1,0 and may be found in its National
Concrete 28 ./ 35
= 0.85 x 28/1.5
= 15.9 N/mm2
For a uniform distribution of load on an area Ac0 (see Figure ) the concentrated CL 6.7 PAGE 111
resistance force may be determined as follows:
FRdu = Ac0 ⋅ fcd ⋅( Ac1 / Ac0 )0.5 ≤ 3,0 ⋅ fcd ⋅ Ac0 where: Ac0 is the loaded area,
Ac1 is the maximum design distribution area with a similar shape to Ac0
A 5+7
CALCULATION SHEET
Office
Mumbai Page No. Cont'n page No.
The design bearing strength of the joint fjd should be determined from:
fjd = βj FRdu / (beff leff) ... (6.6) Page 68 EN 1993-1-8: 2003 (Design of joints)
where:
βj is the foundation joint material coefficient, which may be taken as 2/3 provided that the
characteristic strength of the grout is not less than 0,2 times the characteristic strength of the
concrete foundation and the thickness of the grout is not greater than 0,2 times the smallest width
of the steel base plate. In cases where the thickness of the grout is more than 50 mm, the
characteristic strength of the grout should be at least the same as that of the concrete foundation.
FRdu is the concentrated design resistance force given in EN 1992, where "Ac0 is to be taken as (beff leff).
EN-1993-1-8 6.2.5 pg 67
0.5
c= 15[ 275/ (3 x 21.7 x 1) ]
CALCULATION SHEET
Office
Mumbai Page No. Cont'n page No.
= 16.8 kN
EN 1993-1-8 2003 PG 67
12 + 50 + 50 = 112.0 mm
1
A 7+7
CALCULATION SHEET
Office
Mumbai Page No. Cont'n page No.
Anchors
Tension Check
1.25
Ft,Ed < Ft,Rd OK
Shear Check
= 0.248 also
CALCULATION SHEET
Office
Mumbai Page No. Cont'n page No.
2
2
t = Sqrt (4 x Mbp / fy )
trequired= 12 mm
tprovided= 15 mm Hence OK
A 9+7
BASE PLATE DESIGN with Loadcase 144 and 131 Staad Node 13 and 2
References EC2 Part 1 of 1 EN 1992-1-1 2004
H B
h= 203.2 mm
b= 203.6 mm
tf = 11 mm
tw = 7.2 mm
bb = 450 mm
tp = 20 mm
c = 123.4 mm
Anchors M 24 A - 4.6
Spacing of ha = 300 mm
anchors ba = 300 mm
edge distance e = 75 mm
Fsd.H = 14 KN
Mx = 2 KNm
Mz = 26 KNm
Z= 0.5Z1 + ZT = 246.1 mm
Z1 = 203.2- 11 = 192.2 mm
ZT = 300 / 2 = 150 mm
= 147.5 KN
A 10+7
BASE PLATE DESIGN with Loadcase 144 and 131 Staad Node 13 and 2
References EC2 Part 1 of 1 EN 1992-1-1 2004
Fsd.H = 32 KN
Mx = 3 KNm
Mz = 7 KNm
Z= 0.5Z1 + ZT = 246.1 mm
Z1 = 203.2- 11 = 192.2 mm
ZT = 300 / 2 = 150 mm
αcc is the coefficient taking account of long term effects on the compressive strength and
Note: The value of αcc for use in a Country should lie between 0,8 and 1,0 and may be found in its National
Concrete C32 ./ 35
= 0.85 x 32/1.5
= 18.10 N/mm2
For a uniform distribution of load on an area Ac0 (see Figure ) the concentrated CL 6.7 PAGE 111
FRdu = Ac0 ⋅ fcd ⋅( Ac1 / Ac0 )0.5 ≤ 3,0 ⋅ fcd ⋅ Ac0 where: Ac0 is the loaded area,
Ac1 is the maximum design distribution area with a similar shape to Ac0
A 11+7
BASE PLATE DESIGN with Loadcase 144 and 131 Staad Node 13 and 2
References EC2 Part 1 of 1 EN 1992-1-1 2004
The design bearing strength of the joint fjd should be determined from:
fjd = βj FRdu / (beff leff) ... (6.6) Page 68 EN 1993-1-8: 2003 (Design of joints)
where:
βj is the foundation joint material coefficient, which may be taken as 2/3 provided that the
characteristic strength of the grout is not less than 0,2 times the characteristic strength of the
concrete foundation and the thickness of the grout is not greater than 0,2 times the smallest width
of the steel base plate. In cases where the thickness of the grout is more than 50 mm, the
characteristic strength of the grout should be at least the same as that of the concrete foundation.
FRdu is the concentrated design resistance force given in EN 1992, where "Ac0 is to be taken as (beff leff).
EN-1993-1-8 6.2.5 pg 67
0.5
c= 20[ 355/ (3 x 21.3 x 1) ]
= 147.5 kN
EN 1993-1-8 2003 PG 67
11 + 75 + 123.4 = 257.8 mm
16 KNm
0.0484
Anchors
Tension Check
Max FT,I,E = MAX( 79.5 , 80.94 ) = 80.94 KN ( total tension in two bolts )
1.25
Ft,Ed < Ft,Rd OK
Shear Check
= 0.248 also
2
= 21.3 x47.1 = 23626 Nmm
t = Sqrt (4 x Mbp / fy )
trequired= 16 mm
tprovided= 20 mm Hence OK
Area of steel provided, Arebar =1 * 314 = 314.0 mm2 > 89.933 mm2 OK
σb,sd = T/Abar = 40.47 x 1000 / 314 = 129 N/mm2 ..Ref. cl 8.4 of EN-1992-1-1:2005(E)
= 1 x 1 x 1 x 1 x 1x lb, reqd
= 1.386666667 N/mm2
330mm
fbd = 2.25 x 1 x 1 x 1.3867
= 3.12 N/mm2
75mm
4 x 3.12
= 206.55
lbd = 1 x 1 x 1 x 1 x 1x 206.547
= 206.55 mm
Y = X tan 35 = 42 mm
A 15+7
BASE PLATE DESIGN with Loadcase 144 and 131 Staad Node 13 and 2
References EC2 Part 1 of 1 EN 1992-1-1 2004
Projection = 80 mm Grout = 25 mm
Total Bolt Length required = 404 mm Total Bolt length provided = 510 mm O.K.
BASE PLATE DESIGN with Loadcase 141 and 132 Staad Node 3 and 13
References EC2 Part 1 of 1 EN 1992-1-1 2004
H B
h= 203.2 mm
b= 203.6 mm
tf = 11 mm
tw = 7.2 mm
bb = 450 mm
tp = 20 mm
c = 123.4 mm
Anchors M 24 A - 4.6
Spacing of ha = 300 mm
anchors ba = 300 mm
edge distance e = 75 mm
Fsd.H = 40 KN
Mx = 4 KNm
Mz = 14.5 KNm
Resultant M = Sqrt(M + M ) =
x
2
z
2
15 KNm
Z= 0.5Z1 + ZT = 246.1 mm
Z1 = 203.2- 11 = 192.2 mm
ZT = 300 / 2 = 150 mm
= 62.4 KN
BASE PLATE DESIGN with Loadcase 141 and 132 Staad Node 3 and 13
References EC2 Part 1 of 1 EN 1992-1-1 2004
Fsd.H = 5 KN
Mx = 1.65 KNm
Mz = 10 KNm
Z= 0.5Z1 + ZT = 246.1 mm
Z1 = 203.2- 11 = 192.2 mm
ZT = 300 / 2 = 150 mm
= 82.1 KN
αcc is the coefficient taking account of long term effects on the compressive strength and
Note: The value of αcc for use in a Country should lie between 0,8 and 1,0 and may be found in its National
Concrete C32 ./ 35
= 0.85 x 32/1.5
= 18.10 N/mm2
For a uniform distribution of load on an area Ac0 (see Figure ) the concentrated CL 6.7 PAGE 111
FRdu = Ac0 ⋅ fcd ⋅( Ac1 / Ac0 )0.5 ≤ 3,0 ⋅ fcd ⋅ Ac0 where: Ac0 is the loaded area,
Ac1 is the maximum design distribution area with a similar shape to Ac0
BASE PLATE DESIGN with Loadcase 141 and 132 Staad Node 3 and 13
References EC2 Part 1 of 1 EN 1992-1-1 2004
The design bearing strength of the joint fjd should be determined from:
fjd = βj FRdu / (beff leff) ... (6.6) Page 68 EN 1993-1-8: 2003 (Design of joints)
where:
βj is the foundation joint material coefficient, which may be taken as 2/3 provided that the
characteristic strength of the grout is not less than 0,2 times the characteristic strength of the
concrete foundation and the thickness of the grout is not greater than 0,2 times the smallest width
of the steel base plate. In cases where the thickness of the grout is more than 50 mm, the
characteristic strength of the grout should be at least the same as that of the concrete foundation.
FRdu is the concentrated design resistance force given in EN 1992, where "Ac0 is to be taken as (beff leff).
EN-1993-1-8 6.2.5 pg 67
0.5
c= 20[ 355/ (3 x 21.3 x 1) ]
= 82.1 kN
EN 1993-1-8 2003 PG 67
11 + 75 + 123.4 = 257.8 mm
16 KNm
0.0484
Anchors
Tension Check
Max FT,I,E = MAX( 60.01 , 82.1 ) = 82.10 KN ( total tension in two bolts )
1.25
Ft,Ed < Ft,Rd OK
Shear Check
= 0.248 also
2
= 21.3 x47.1 = 23626 Nmm
t = Sqrt (4 x Mbp / fy )
trequired= 16 mm
tprovided= 20 mm Hence OK
Area of steel provided, Arebar =1 * 314 = 314.0 mm2 > 91.222 mm2 OK
σb,sd = T/Abar = 41.05 x 1000 / 314 = 131 N/mm2 ..Ref. cl 8.4 of EN-1992-1-1:2005(E)
= 1 x 1 x 1 x 1 x 1x lb, reqd
= 1.386666667 N/mm2
330mm
fbd = 2.25 x 1 x 1 x 1.3867
= 3.12 N/mm2
75mm
4 x 3.12
= 209.51
lbd = 1 x 1 x 1 x 1 x 1x 209.5072
= 209.51 mm
Y = X tan 35 = 42 mm
BASE PLATE DESIGN with Loadcase 141 and 132 Staad Node 3 and 13
References EC2 Part 1 of 1 EN 1992-1-1 2004
Projection = 75 mm Grout = 25 mm
Total Bolt Length required = 402 mm Total Bolt length provided = 405 mm O.K.
SHEAR LUG DESIGN
300
300
600
#REF!
G=25
Grout H=100
Shear Lug
25.000
Input Data:
Column Loadings:
Shear Load, V(total) = 116.00 KN
Axial Load, P(DL) = 0 KN
Vc >=V, O.K.
Ultimate fillet weld capacity for S355 baseplate with and shear key joined at 90deg
Weld s = 6.0000 mm
Throat thickness = 0.707s= 4.242 mm
Longitudinal capacity = 1.05 kN/mm Refer Table
472.5 kN
H B
tf = 14 mm
bb = 450 mm
tp = 20 mm
assume c = 105 mm
Anchors M 20 Z - 8.8
Fub = 800
Spacing of anchors
ha = 300
ba = 300
edge distance e = 75
Fsd.H = 2.83 KN
Mx = 8.7 KNm
Mz = 0 KNm
= 0
Z= 0.5Z1 + ZT = 263 mm
Z1 = 240- 14 = 226 mm
ZT = 300 / 2 = 150 mm
= 26.45 KN
= 41.9 KN
Design bearing strength
Concrete C28 ./ 35
= 1 x 28/1.5
= 18.70 N/mm2
d1 = bp = 450 mm
b2 = 224+ 2 x 75 = 374 mm
d2 = 3 x 450 = 1350 mm
as per EN-1993-1-8-6.2.5
0.5
C= 20[ 235 / (3 x fjd x Ymo ) ]
beff = 75 + 14 + 33.4
beff = 122.4 mm
leff = bp = 450 mm
10.6 KNm
( 300 - 240 ) = 30 mm
0.03
Anchors
as per EN-1993-1-8-6.2.5
Table 3.4
1.25
Thickness of base plate
2
= 28.1 x33.4 = 15674 Nmm
t = Sqrt (6 x Mbp / fy )
t = 20 mm
Shear check
= 0.6
fyb = 640
also
therefore
1.25