PEAD
60-140V/200/250
Wi-Fi
POWER INVERTER Interface
Optional Optional Optional Optional Optional
Connectable to
The optional Plasma Quad Connect MAC-100FT-E can be installed on the indoor unit's air inlet side. For installation, PQ attachment or PQ box is
required.
21 22
60-140V/200/250 PUHZ
Wi-Fi
Interface
JAQ
POWER INVERTER
SERIES SELECTION
Optional
Wi-Fi
Interface
JAQ
Standard Inverter Series Joint Lap Vector Sine Wave DC Rotary DC Scroll DC Fan Motor Vector-Wave Grooved Piping
Fixing Method
Type Inverter Heat Pump
Indoor Unit PEAD-M35JA(L)2 PEAD-M50JA(L)2 PEAD-M60JA(L)2 PEAD-M71JA(L)2 PEAD-M100JA(L)2 PEAD-M100JA(L)2 PEAD-M125JA(L)2 PEAD-M125JA(L)2 PEAD-M140JA(L)2 PEAD-M140JA(L)2
Indoor Unit Outdoor Unit Outdoor Unit SUZ-M35VA SUZ-M50VA SUZ-M60VA SUZ-M71VA PUZ-M100VKA2 PUZ-M100YKA2 PUZ-M125VKA2 PUZ-M125YKA2 PUZ-M140VKA2 PUZ-M140YKA2
Refrigerant(*1) R32
Power Source Outdoor power supply
Supply Outdoor(V/Phase/Hz) VA.VKA:230/Single/50, YKA:400/Three/50
Cooling Capacity Rated kW 3.6 5.0 6.1 7.1 9.5 9.5 12.1 12.1 13.4 13.4
Min-Max kW 0.8 - 3.9 1.7 - 5.6 1.6 - 6.3 2.2 - 8.1 4.0 - 10.6 4.0 - 10.6 6.0 - 13.0 6.0 - 13.0 6.1 - 14.1 6.1 - 14.1
Total Input Rated kW 0.923 1.351 1.694 2.028 2.878 2.878 4.019 4.019 4.768 4.768
For Single EER(*4) 3.90 3.70 3.60 3.50 3.30 3.30 3.01 3.01 2.81 2.81
Design load kW 3.6 5.0 6.1 7.1 9.5 9.5 --- --- --- ---
Annual electricity consumption (*2) kWh/a 199 277 345 397 538 538 --- --- --- ---
SUZ-M35 SUZ-M50 SUZ-M60/71 PUZ-M100/125/140 SEER(*4)(*5) 6.3 6.3 6.1 6.2 6.1 6.1 --- --- --- ---
Energy efficiency class A++ A++ A++ A++ A++ A++ --- --- --- ---
Heating Capacity Rated kW 4.1 6.0 7.0 8.0 11.2 11.2 13.5 13.5 15.0 15.0
Min-Max kW 1.1 - 5.0 1.5 - 7.2 1.6 - 8.0 2.0 - 10.2 2.8 - 12.5 2.8 - 12.5 4.1 - 15.0 4.1 - 15.0 4.2 - 15.8 4.2 - 15.8
Total Input Rated kW 1.025 1.463 1.842 2.105 2.947 2.947 3.739 3.739 4.155 4.155
COP(*4) 4.00 4.10 3.80 3.80 3.80 3.80 3.61 3.61 3.61 3.61
Design load kW 2.6 4.3 4.6 5.8 8.0 8.0 --- --- --- ---
Declared Capacity at reference design temperature kW 2.3 (-10℃) 3.8 (-10°C) 4.1 (-10°C) 5.2 (-10°C) 6.0 (-10°C) 6.0 (-10°C) --- --- --- ---
PEAD-M35/50/60/71/100/125/140JA(L)2 For Multi at bivalent temperature kW 2.3 (-7℃) 3.8 (-7°C) 4.1 (-7°C) 5.2 (-7°C) 7.0 (-7°C) 7.0 (-7°C) --- --- --- ---
(Twin/Triple/Quadruple) at operation limit temperature kW 2.3 (-10℃) 3.8 (-10°C) 4.1 (-10°C) 5.2 (-10°C) 4.5 (-15°C) 4.5 (-15°C) --- --- --- ---
Back up heating capacity kW 0.3 0.5 0.5 0.6 2.0 2.0 --- --- --- ---
Annual electricity consumption (*2)
kWh/a 884 1417 1558 1973 2725 2725 --- --- --- ---
SCOP(*4)(*5) 4.1 4.2 4.1 4.1 4.1 4.1 --- --- --- ---
PUZ-M100/125/140 PUZ-M200/250 Energy efficiency class A+ A+ A+ A+ A+ A+ --- --- --- ---
Operating Current(Max) A 9.7 14.9 16.7 16.7 22.3 13.8 27.8 12.8 31.4 12.9
Remote Controller Indoor
Unit
Input [cooling / Heating ]
Operating Current(Max)
Rated kW
A
0.05
1.16
0.07 0.08
1.85
0.09
1.9
0.14
2.25
0.14
2.25
0.20
2.34
0.20
2.34
0.21
2.63
0.21
2.63
1.35
Dimensions H*W*D mm 250×900×732 250×900×732 250×1100×732 250×1100×732 250×1400×732 250×1400×732 250×1400×732 250×1400×732 250×1600×732 250×1600×732
Weight kg 25(24.5) 26.5(25.5) 29.5(29) 29.5(29) 37(36) 37(36) 38(37) 38(37) 42(41) 42(41)
Air Volume (Lo-Mid-Hi) m3/min 10.0-12.0-14.0 12.0-14.5-17.0 14.5-18.0-21.0 14.5-18.0-23.0 23.0-28.0-32.0 23.0-28.0-32.0 28.0-34.0-37.0 28.0-34.0-37.0 29.5-35.5-40.0 29.5-35.5-40.0
External Static Pressure(*7) Pa 35-<50>-<70>-<100>-<150> 40-<50>-<70>-<100>-<150> <40>-50-<70>-<100>-<150>
Optional Optional Optional Optional✽ Optional✽ Sound Level (Lo-Mid-Hi) (SPL) dB(A) 24-29-32 27-33-35 26-32-35 26-32-37 31-36-39 31-36-39 35-39-41 35-39-41 34-38-41 34-38-41
Sound Level (PWL) dB(A) 54 58 56 58 62 62 66 66 66 66
✽ PAR-SC9CA-E is also required. Outdoor Dimensions H*W*D mm 550-800-285 714-800-285 880-840-330 880-840-330 981-1050-330(+40) 981-1050-330(+40) 981-1050-330(+40) 981-1050-330(+40) 981-1050-330(+40) 981-1050-330(+40)
Unit Weight kg 35 41 54 55 76 78 84 85 84 85
PEAD-M JA(L)2 Indoor Unit Combinations Indoor unit combinations shown below are possible. Air Volume Cooling m3/min 34.3 45.8 50.1 50.1 79 79 86 86 86 86
Heating m3/min 32.7 43.7 50.1 50.1 79 79 92 92 92 92
Sound Level (SPL) Cooling dB(A) 48 48 49 49 51 51 54 54 55 55
Outdoor Unit Capacity Heating dB(A) 48 49 51 51 54 54 56 56 57 57
Sound Level (PWL) Cooling dB(A) 59 64 65 66 70 70 72 72 73 73
Indoor Unit Combination For Single For Twin For Triple For Quadruple Operating Current(Max) A 8.5 13.5 14.8 14.8 20 11.5 26.5 11.5 30 11.5
Breaker Size A 16 20 20 20 32 16 32 16 40 16
Ext.Piping Diameter(*6) Liquid/Gas mm 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
35 50 60 71 100 125 140 200 250 71 100 125 140 200 250 140 200 250 200 250 Max.Length Out-In m 20 30 30 30 55 55 65 65 65 65
Max.Height Out-In m 12 30 30 30 30 30 30 30 30 30
Guaranteed Operating Range(Outdoor) Cooling(*3) °C -10 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46
Standard Inverter (PUZ-M& SUZ) 35x1 50x1 60x1 71x1 100x1 125x1 140x1 – – – 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4
Heating °C -10 ~ +24 -10 ~ +24 -10 ~ +24 -10 ~ +24 -15 ~ +21 -15 ~ +21 -15 ~ +21 -15 ~ +21 -15 ~ +21 -15 ~ +21
Distribution Pipe – – – – – – – – – – MSDD-50TR2-E MSDD- MSDT-111R3-E MSDF- *1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
50WR2-E 1111R2-E contains a refrigerant fluid with a GWP equal to 550. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 550 times higher than 1 kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. The GWP of R32 is 675 in the IPCC 4th Assessment Report.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 EER/COP and SEER/SCOP for M35-71 are measured at ESP 35Pa, for M100 at ESP 37Pa, for M125/140 at ESP 50Pa.
23 *5 SEER and SCOP are based on 2009/125/EC:Energy-related Products Directive and Regulation(EU) No206/2012. *6 Joint pipe is required depending on installed refrigerant pipes, outdoor units and indoor units. 24
*7 The factory setting of ESP is shown without < >.
60-140V/200/250 PUHZ
Wi-Fi
Interface
JAQ
POWER INVERTER
Optional
Wi-Fi
Interface
JAQ
Standard Inverter Series Joint Lap Vector Sine Wave DC Rotary DC Scroll DC Fan Motor Vector-Wave Grooved Piping
Fixing Method
Type Inverter Heat Pump
Indoor Unit PEAD-M35JA(L)2 PEAD-M50JA(L)2 PEAD-M60JA(L)2 PEAD-M71JA(L)2 PEAD-M100JA(L)2 PEAD-M100JA(L)2 PEAD-M125JA(L)2 PEAD-M125JA(L)2 PEAD-M140JA(L)2 PEAD-M140JA(L)2
Outdoor Unit SUZ-KA35VA6 SUZ-KA50VA6 SUZ-KA60VA6 SUZ-KA71VA6 PUHZ-P100VKA PUHZ-P100YKA PUHZ-P125VKA PUHZ-P125YKA PUHZ-P140VKA PUHZ-P140YKA
Indoor Unit Outdoor Unit Refrigerant(*1) R410A
Power Source Outdoor power supply
Supply Outdoor(V/Phase/Hz) VA・VKA:230/Single/50, YKA:400/Three/50
Cooling Capacity Rated kW 3.6 4.9 5.7 7.1 9.4 9.4 12.1 12.1 13.6 13.6
Min-Max kW 1.4 - 3.9 2.3 - 5.6 2.3 - 6.3 2.8 - 8.1 3.7 - 10.6 3.7 - 10.6 5.6 - 13.0 5.6 - 13.0 5.8 - 14.1 5.8 - 14.1
Total Input Rated kW 1.029 1.458 1.652 2.060 2.965 2.965 4.143 4.143 5.551 5.551
EER(*4) 3.50 3.36 3.45 3.45 3.17 3.17 2.92 2.92 2.45 2.45
For Single Design load kW 3.6 4.9 5.7 7.1 9.4 9.4 --- --- --- ---
Annual electricity consumption (*2) kWh/a 210 284 326 395 596 596 --- --- --- ---
SUZ-KA35 SUZ-KA50/60/71 PUHZ-P100/125/140 SEER(*4)(*5) 6.0 6.0 6.1 6.2 5.5 5.5 --- --- --- ---
Energy efficiency class A+ A+ A++ A++ A A --- --- --- ---
Heating Capacity Rated kW 4.1 5.9 7.0 8.0 11.2 11.2 13.5 13.5 15.0 15.0
Min-Max kW 1.7 - 5.0 1.7 - 7.2 2.5 - 8.0 2.6 - 10.2 2.8 - 12.5 2.8 - 12.5 4.8 - 15.0 4.8 - 15.0 4.9 - 15.8 4.9 - 15.8
Total Input Rated kW 1.111 1.620 1.928 2.040 2.947 2.947 3.739 3.739 4.347 4.347
COP(*4) 3.69 3.64 3.63 3.80 3.80 3.80 3.61 3.61 3.45 3.45
Design load kW 2.8 4.4 4.5 6.0 8.0 8.0 --- --- --- ---
Declared Capacity at reference design temperature kW 2.5 (-10°C) 3.9 (-10°C) 4.1 (-10°C) 5.3 (-10°C) 6.0 (-10°C) 6.0 (-10°C) --- --- --- ---
For Multi at bivalent temperature kW 2.5 (-7°C) 3.9 (-7°C) 4.1 (-7°C) 5.3 (-7°C) 7.0 (-7°C) 7.0 (-7°C) --- --- --- ---
PEAD-M35/50/60/71/100/125/140JA(L)2 (Twin/Triple/Quadruple) at operation limit temperature kW 2.5 (-10°C) 3.9 (-10°C) 4.1 (-10°C) 5.3 (-10°C) 4.5 (-15°C) 4.5 (-15°C) --- --- --- ---
Back up heating capacity kW 0.3 0.5 0.4 0.7 2.0 2.0 --- --- --- ---
Annual electricity consumption (*2) kWh/a 975 1455 1559 2132 2797 2797 --- --- --- ---
SCOP(*4)(*5) 4.0 4.2 4.0 3.9 4.0 4.0 --- --- --- ---
PUHZ-P100/125/140 PUHZ-P200/250 Energy efficiency class A+ A+ A+ A A+ A+ --- --- --- ---
Operating Current(Max) A 9.4 13.4 15.9 18.0 22.3 13.8 27.8 12.8 31.4 12.9
Indoor Input [cooling / Heating ] Rated kW 0.05 0.07 0.08 0.09 0.14 0.14 0.20 0.20 0.21 0.21
Remote Controller Unit Operating Current(Max) A 1.16 1.35 1.85 1.9 2.25 2.25 2.34 2.34 2.63 2.63
Dimensions H*W*D mm 250×900×732 250×900×732 250×1100×732 250×1100×732 250×1400×732 250×1400×732 250×1400×732 250×1400×732 250×1600×732 250×1600×732
Weight kg 25(24.5) 26.5(25.5) 29.5(29) 29.5(29) 37(36) 37(36) 38(37) 38(37) 42(41) 42(41)
Air Volume (Lo-Mid-Hi) m3/min 10.0-12.0-14.0 12.0-14.5-17.0 14.5-18.0-21.0 14.5-18.0-23.0 23.0-28.0-32.0 23.0-28.0-32.0 28.0-34.0-37.0 28.0-34.0-37.0 29.5-35.5-40.0 29.5-35.5-40.0
External Static Pressure(*7) Pa 35-<50>-<70>-<100>-<150> 40-<50>-<70>-<100>-<150> <40>-50-<70>-<100>-<150>
Optional Optional Optional Optional✽ Optional✽ Sound Level (Lo-Mid-Hi) (SPL) dB(A) 24-29-32 27-33-35 26-32-35 26-32-37 31-36-39 31-36-39 35-39-41 35-39-41 34-38-41 34-38-41
Sound Level (PWL) dB(A) 54 58 56 58 62 62 66 66 66 66
Outdoor Dimensions H*W*D mm 550-800-285 880-840-330 880-840-330 880-840-330 981-1050-330 981-1050-330 981-1050-330 981-1050-330 981-1050-330 981-1050-330
✽ PAR-SC9CA-E is also required.
PEAD-M JA(L) Indoor Unit Combinations Indoor unit combinations shown below are possible. Unit Weight
Air Volume Cooling
kg
m3/min
35
36.3
54
44.6
50
40.9
53
50.1
76
79
78
79
84
86
85
86
84
86
85
86
Heating m3/min 34.8 44.6 49.2 48.2 79 79 92 92 92 92
Sound Level (SPL) Cooling dB(A) 49 52 55 55 51 51 54 54 56 56
Outdoor Unit Capacity
Heating dB(A) 50 52 55 55 54 54 56 56 57 57
Sound Level (PWL) Cooling dB(A) 62 65 65 69 70 70 72 72 75 75
Indoor Unit Combination For Single For Twin For Triple For Quadruple Operating Current(Max) A 8.2 12 14 16.1 20 11.5 26.5 11.5 30 11.5
Breaker Size A 10 20 20 20 32 16 32 16 40 16
Ext.Piping Diameter(*6) Liquid/Gas mm 6.35 / 9.52 6.35 / 12.7 6.35 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
35 50 60 71 100 125 140 200 250 71 100 125 140 200 250 140 200 250 200 250 Max.Length Out-In m 20 30 30 30 50 50 50 50 50 50
Max.Height Out-In m 12 30 30 30 30 30 30 30 30 30
Standard Inverter (PUHZ-P & SUZ) 35x1 50x1 60x1 71x1 100x1 125x1 140x1 – – – 50x2 60x2 71x2 100x2 125x2 50x3 60x3 71x3 50x4 60x4 Guaranteed Operating Range(Outdoor) Cooling(*3) °C -10 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46 -15 ~ +46
Heating °C -10 ~ +24 -10 ~ +24 -10 ~ +24 -10 ~ +24 -15 ~ +21 -15 ~ +21 -15 ~ +21 -15 ~ +21 -15 ~ +21 -15 ~ +21
*1 Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance
Distribution Pipe – – – – – – – – – – MSDD-50TR-E MSDD-50WR-E MSDT-111R-E MSDF-1111R-E contains a refrigerant fluid with a GWP equal to 550. This means that if 1 kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 550 times higher than 1 kg of CO2, over a period
of 100 years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. The GWP of R32 is 675 in the IPCC 4th Assessment Report.
*2 Energy consumption based on standard test results. Actual energy consumption will depend on how the appliance is used and where it is located.
*3 Optional air protection guide is required where ambient temperature is lower than –5°C. *4 EER/COP and SEER/SCOP for M35-71 are measured at ESP 35Pa, for M100 at ESP 37Pa, for M125/140 at ESP 50Pa.
*5 SEER and SCOP are based on 2009/125/EC:Energy-related Products Directive and Regulation(EU) No206/2012. *6 Joint pipe is required depending on installed refrigerant pipes, outdoor units and indoor units.
25 *7 The factory setting of ESP is shown without < >. 26