The document provides construction notes for a project, including:
1. General notes stating that construction notes and details apply to all drawings, and contractors must verify dimensions and coordinate with other contractors.
2. Concrete notes specifying minimum compressive strengths and maximum aggregate sizes for different elements, as well as reinforcement requirements.
3. Masonry notes including requirements for concrete masonry units, reinforcement, and grout.
4. A note indicating the foundation design was based on an assumed soil bearing capacity.
The document provides construction notes for a project, including:
1. General notes stating that construction notes and details apply to all drawings, and contractors must verify dimensions and coordinate with other contractors.
2. Concrete notes specifying minimum compressive strengths and maximum aggregate sizes for different elements, as well as reinforcement requirements.
3. Masonry notes including requirements for concrete masonry units, reinforcement, and grout.
4. A note indicating the foundation design was based on an assumed soil bearing capacity.
1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS
UNLESS OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS. 2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL STEELS, MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED FOR ENGINEER’S APPROVAL BEFORE FABRICATION. 3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN CHECK WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR CONDUITS PIPE SLEEVES, ETC., TO BE EMBEDDED IN CONCRETE. 4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING & BRA- CINGS OF THE STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING CONSTRUCTION.
B. CONCRETE AND REINFORCEMENT
1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM WITH THE LATEST
NATIONAL BUILDING CODE OF THE PHILIPPINES AND NSCP 2015. 2. ALL CONCRETE SHALL DEVELOP A MIN. COMPRESSIVE STRENGTH AT THE END OF TWENTY EIGHT (28) DAYS W/ CORRESPONDING MAXIMUM SIZE AGGREGATE & SLUMPS AS FOLLOWS.
LOCATION MINIMUM MAXIMUM SIZE MAXIMUM
COMPRESSIVE OF AGREGGATES SLUMP STRENGTH AT 28 DAYS FOUNDATION 20.7 MPA (3000 ¾ IN. (19 MM) 4 IN. (100 MM) FOOTING PSI) COLUMNS 20.7 MPA (3000 ¾ IN. (19 MM) 4 IN. (100 MM) PSI) BEAMS, SLABS 20.7 MPA (3000 ¾ IN. (19 MM) 4 IN. (100 MM) PSI) SLAB ON GRADE 20.7 MPA (3000 ¾ IN. (19 MM) 4 IN. (100 MM) PSI) 3. ALL REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 275 FOR DIAMETER ALL REINFORCING BARS. 4. IN GENERAL, THE LATEST EDITION OF ACI-315, MANUAL OF STANDARD PRACTICE DETAILING REINFORCED CONCRETE STRUCTURES SHALL BE ADHERED TO UNLESS OTHERWISE SHOWN OR NOTED. 5. MAINTAIN MINIMUM CONCRETE COVER FOR REINFORCING STEEL AS FOLLOWS. SUSPENDED SLABS---------------------------------------------------------- ---------------¾ IN. (19 MM) SLAB ON GRADE------------------------------------------------------------ ----------------1- 1/2 IN. (40MM) WALLS ABOVE GRADE------------------------------------------------------- --------------1 IN. (25MM) BEAMS STIRRUPS AND COLUMN TIES----------------------------------------- --------1 -1/2 IN. (40MM) WHERE CONCRETE IS EXPOSED TO EARTH BUT POURED AGAINST FORMS---------------------------------------- ------- 2 IN. (50 MM) WHERE CONCRETE IS DEPOSITED DIRECTLY AGAINST EARTH--------------------------------------------------- ------------3 IN. (75MM) 6. SPLICES SHALL BE SECURELY WIRED TOGETHER & SHALL LAP OR EXTEND IN ACCORDANCE W/ TABLE 1 (TABLE OF LAP SPLICE & ANCHORAGE LENGTH) UNLESS OTHERWISE SHOWN ON DRAWINGS, SPLICES SHALL BE STAGGERED WHENEVER POSSIBLE. 7. ALL ANCHOR BOLTS, DOWELS, AND OTHER INSERTS, SHALL BE PROPERLY POSITIONED & SECURED IN PLACE PRIOR TO PLACING OF CONCRETE. 8. CONTRACTOR SHALL NOTE AND PROVIDE ALL MISCELLANEOUS CURBS, SILLS, STOOLS, EQUIPMENT'S AND MECHANICAL BASES THAT ARE REQUIRED BY THE ARCHITECTURAL, ELECTRICAL, AND MECHANICAL DRAWINGS. 9. ALL CONCRETE SHALL BE KEPT MOIST FOR A MINIMUM OF SEVEN CONSECUTIVE DAYS IMMEDIATELY AFTER POURING BY THE USE OF WET BURLAP FOG SPRAYING, CURING COMPOUNDS OR OTHER APPROVED METHODS. 10. STRIPPING OF FORMS AND SHORES: FOUNDATION--------------------------------------------------------------- ----------------24 HRS SUSPENDED SLAB EXCEPT WHEN ADDITIONAL LOADS ARE IMPOSED------------------------------------------- ---------8 DAYS WALLS---------------------------------------------------------------------- ------------------18 HRS BEAMS---------------------------------------------------------------------- -----------------14 DAYS C. MASONRY AND CONCRETE BLOCKS 1. ALL NON-LOAD BEARING TYPE CONCRETE BLOCKS SHALL HAVE A UNIT WEIGHT NOT TO EXCEED 80 PCF. FOR LOAD BEARING TYPE, TYPE CONCRETE BLOCKS, A MINIMUM COMPRESSIVE STRENGTH OF 6.90 MPA SHALL BE DEVELOPED. 2. PROVIDE 1-∅16 VERTICAL BARS AT CORNERS, INTERSECTIONS, END OF WALLS AND EACH SIDE OF OPENINGS. 3. LINTEL BEAMS SHALL BEAR AT LEAST 8 INCHES (200 MM) ON EACH SIDE OF MASONRY WALL OPENING. 4. WALL REINFORCEMENTS SHALL BE AS FOLLOWS. WALL THICKNESS VERTICAL HORIZONTAL REINFORCEMENT REINFORCEMENT 8 IN. (200MM) Ø12@400MM Ø10@600MM 6 IN. (150MM) Ø10@400MM Ø10@600MM 4 IN. (100MM) Ø10@400MM Ø10@600MM 5. REINFORCING BARS SHALL BE LAPPED A MINIMUM OF 40 BAR DIAMETERS WHERE SPLICE DOWELS FROM FOOTING OR SLABS SHALL EXTEND INTO THE BLOCK WALL A MINIMUM OF 40 BAR DIAMETERS, AND DOWELS TO MATCH. 6. ALL CELLS CONTAINING REINFORCING BARS OR INSERTS SHALL BE SOLIDLY FILLED WITH CONCRETE GROUT (REFER TO SPECIFICATIONS). D. FOUNDATION 1. FOUNDATION DESIGN WAS BASED ON ASSUMED SOIL BEARING CAPACITY OF 70KPA