Scalance - x1011 Commisioning Manual
Scalance - x1011 Commisioning Manual
Introduction 2
Network Topologies 3
Product Characteristics 4
SIMATIC NET
Industrial Ethernet 5
Installation and Maintenance
SCALANCE X101-1
SCALANCE X101-1FL 6
SCALANCE X101-1LD Notes on the CE Mark
SCALANCE X101-1POF
Commissioning Manual References 7
Dimension Drawings 8
07/2008
A2B00051521A
Safety Guidelines
This manual contains notices which you should observe to ensure your own personal safety as well as to avoid
property damage. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring to property damage only have no safety alert symbol. Depending on the danger level,
the notices are displayed in descending order as follows.
Danger
indicates that death or severe personal injury will result if proper precautions are not taken.
Warning
indicates that death or severe personal injury may result if proper precautions are not taken.
Caution
with safety alert symbol indicates that minor personal injury can result if proper precautions are not taken.
Caution
without safety alert symbol indicates that property damage can result if proper precautions are not taken.
Notice
indicates that an unintended result or situation can occur if the corresponding information is not taken into
account.
When several danger levels apply, the notices of the highest level (lower number) are always displayed. If a
notice refers to personal damages with the safety alert symbol, then another notice may be added warning of
property damage.
Qualified Personnel
The device/system may only be set up and operated in conjunction with this documentation. Only qualified
personnel should be allowed to install and work on the equipment. Only qualified personnel should be allowed to
install and work on the equipment. Qualified persons are defined as persons who are authorized to commission,
to earth, and to tag circuits, equipment and systems in accordance with established safety practices and
standards.
Intended Use
Please note the following:
Warning
This device and its components may only be used for the applications described in the catalog or technical
description, and only in connection with devices or components from other manufacturers approved or
recommended by Siemens. This product can only function correctly and safely if it is transported, stored, set up
and installed correctly, and operated and maintained as recommended.
Trademarks
All designations marked with ® are registered trademarks of Siemens AG. Other designations in this
documentation might be trademarks which, if used by third parties for their purposes, might infringe upon the
rights of the proprietors.
Siemens AG
Automation and Drives Group Siemens AG 2008
P.O. Box 4848, D-90327 Nuremberg (Germany) Technical data subject to change
Tables
Figures
Figure 3-1 Electrical/optical bus topology with SCALANCE X101-1 ........................................................... 3-1
Figure 3-2 Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a
extension for Optical Lines with SCALANCE X101-1LD Media converter ................................ 3-2
Figure 3-3 Electrical Ring, Example with SCALANCE X204IRT as Redundancy Manager, X208 and
conversion to a Optical Line with SCALANCE X101-1 or X101-1LD Media converter ............. 3-2
Figure 3-4 Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a
extension for Optical Lines with SCALANCE X101-1LD Media converter ................................ 3-3
Figure 3-5 Stand-By Coupling of two Redundant Rings via Master / Slave Concept of SCALANCE X-400.
Coupling is realized with SCALANCE X101-1 or X101-1LD Media converter .......................... 3-4
Figure 4-1 SCALANCE X101-1 ................................................................................................................... 4-3
Figure 4-2 RJ-45 connector pinout.............................................................................................................. 4-4
Figure 4-3 Power supply SCALANCE X101-1 ............................................................................................ 4-6
Figure 4-4 Connector pinout........................................................................................................................ 4-6
Figure 4-5 Signaling contact SCALANCE X101-1 ...................................................................................... 4-7
Figure 4-6 Connector pinout........................................................................................................................ 4-7
Figure 4-7 SCALANCE X101-1FL............................................................................................................. 4-15
Figure 4-8 RJ-45 connector pinout............................................................................................................ 4-16
Figure 4-9 Power supply SCALANCE X101-1FL ...................................................................................... 4-18
Figure 4-10 Connector pinout...................................................................................................................... 4-18
Figure 4-11 Signaling contact SCALANCE X101-1FL ................................................................................ 4-19
Figure 4-12 Connector pinout...................................................................................................................... 4-19
Figure 4-13 SCALANCE X101-1LD ............................................................................................................ 4-27
Figure 4-14 RJ-45 connector pinout............................................................................................................ 4-28
Figure 4-15 Power supply SCALANCE X101-1LD...................................................................................... 4-30
Figure 4-16 Connector pinout...................................................................................................................... 4-30
Figure 4-17 Signaling contact SCALANCE X101-1LD ............................................................................... 4-31
Figure 4-18 Connector pinout...................................................................................................................... 4-31
Figure 4-19 SCALANCE X101-1POF.......................................................................................................... 4-39
Figure 4-20 RJ-45 connector pinout............................................................................................................ 4-40
Figure 4-21 Power supply SCALANCE X101-1POF................................................................................... 4-42
Figure 4-22 Connector pinout...................................................................................................................... 4-42
Figure 4-23 Signaling contact SCALANCE X101-1POF ............................................................................. 4-43
Figure 4-24 Connector pinout...................................................................................................................... 4-43
Figure 5-1 Installation on a DIN rail (35 mm) .............................................................................................. 5-2
Figure 5-2 Removing from a DIN rail (35 mm) ............................................................................................ 5-3
Figure 5-3 Installation on a SIMATIC S7-300 DIN rail ................................................................................ 5-4
Figure 5-4 IE FC RJ-45 plug 180 ................................................................................................................ 5-6
Figure 5-5 Inserting the IE FC RJ-45 plug 180 ........................................................................................... 5-7
Figure 5-6 Unlatching the RJ-45 plug.......................................................................................................... 5-8
Figure 8-1 Dimension drawing .................................................................................................................... 8-1
Figure 8-2 Dimension drawing / Side view .................................................................................................. 8-2
Figure 8-3 Bending radii .............................................................................................................................. 8-3
Further Documentation
The “SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks” manual
contains additional information on other SIMATIC NET products that you can operate along
with the media converters of the SCALANCE X-100 series in an Industrial Ethernet network.
Finding information
To help you to find the information you require more quickly, the manual includes not only
the table of contents but also the following sections in the Appendix:
• Glossary
• Index
Audience
This commissioning manual is intended for persons involved in the commissioning of
networks with the media converters of the SCALANCE X-100 series.
The media converters of the SCALANCE X-100 series meet the requirements for the UL , C-
Tick , FM and ATEX marks . For detailed information please refer to the technical
specifications of the respective media converter in the “Approvals” heading of this
commissioning manual.
What Is Possible?
The media converters of the SCALANCE X-100 series enable the cost-effective installation
of Industrial Ethernet bus and star structures with media transitions.
Note
The passive use of two identical SCALANCE X-100 media converters1 in cascade connec-
tion (series connection) within a redundant ring is possible. The media converters act as a
“ line section” .
Note
The requirements of EN61000-4-5, surge test on power supply lines, are met only when a
Blitzductor VT AD 24V type no. 918 402 is used
Manufacturer:
DEHN+SÖHNE GmbH + Co. KG Hans Dehn Str.1 Postfach 1640 D-92306 Neumarkt,
Germany
1
Only SCALANCE X101-1 or SCALANCE X101-1LD or SCALANCE X101-1POF
Warning
When used under hazardous conditions (zone 2), the media converter of the SCALANCE X-
100 series must be installed in an enclosure.
In the scope of ATEX100a (EN 60079-15), this enclosure must at least comply with IP54
according to EN 60529.
Note
The specified approvals apply only when the corresponding mark is printed on the product.
Bus Topology
2
Only SCALANCE X101-1 or SCALANCE X101-1LD or SCALANCE X101-1POF
Star Topology
Figure 3-2 Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a
extension for Optical Lines with SCALANCE X101-1LD Media converter
Ring Topology
See in chapter 4 Product Characteristics, subsection Cascade, of the concerning media
converter.
Figure 3-3 Electrical Ring, Example with SCALANCE X204IRT as Redundancy Manager, X208 and
conversion to a Optical Line with SCALANCE X101-1 or X101-1LD Media converter
Figure 3-4 Optical Ring, Example with SCALANCE X-400 as Redundancy Manager, X204-2 and a
extension for Optical Lines with SCALANCE X101-1LD Media converter
Figure 3-5 Stand-By Coupling of two Redundant Rings via Master / Slave Concept of SCALANCE
X-400. Coupling is realized with SCALANCE X101-1 or X101-1LD Media converter
Unpacking, Checking
1. Make sure that the package is complete.
2. Check all parts for transport damage.
Warning
Do not use any parts that show evidence of damage!
Warning
If the SCALANCE X101-1 device is operated in ambient temperatures between 55°C-
60°C, the temperature of the device housing may be higher than 70°C.
The subject unit must be located in a Restricted Access Location where access can only
be gained by SERVICE PERSONNEL or by USERS who have been instructed about the
reasons for the restrictions applied to the location and about any precautions that shall be
taken when operated in an ambient temperature of 55°C-60°C.
Possible Attachments
The SCALANCE X101-1 media converter features an RJ-45 jack and a BFOC port for the
connection of DTEs or other network segments.
Note
The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket
Connector Pinout
RJ-45 jack
On SCALANCE X101-1, the twisted pair port is implemented as RJ-45 jack with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Notice
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP
port.
Depending on the cable type, a total cable length of up to 100 m is permitted between two
devices with the IE FC cables and IE FC RJ-45 plug 180.
Autonegotiation
Autonegotiation means the automatic detection of the functionality of the port at the opposite
end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the
port of a partner device allowing automatic configuration of different types of device. With
autonegotiation, two components connected to a link segment can exchange parameters
and set themselves to match the supported communication functionality.
Note
Devices not supporting autonegotiation must be set to 100 Mbps / half duplex.
Transmission Speed
The transmission rate of the optical Fast Ethernet port is 100 Mbps.
Transmission Mode
The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard.
Since the full duplex mode and the transmission rate cannot be modified for optical
transmission, autonegotiation cannot be selected.
Transmission Medium
The data are transferred over multimode fiber-optic cable (FOC). The transceiver wavelength
is 1300 nm.
Multimode fiber-optic cables are used with a core diameter of 50 or 62.5 µm, the light source
is an LED.
The outer diameter of the FOC is 125 µm.
Range
The maximum transmission range (segment length) is 3 km if the signal attenuation of the
FOC is ≤ 1 dB/km at 1300 nm.
Connectors
The cables are connected to BFOC sockets.
Power Supply
The power supply is connected using a 4-pin plug-in terminal block. The power supply can
be connected redundantly. Both inputs are isolated. There is no distribution of load. When
using a redundant power supply, the power supply unit with the higher output voltage
supplies SCALANCE X101-1 alone. The power supply is connected over a high resistance
with the enclosure to allow an ungrounded setup.
Figure 4-3 Power supply SCALANCE X101-1 Figure 4-4 Connector pinout
Pin number Pinout
Pin 1 L1+ (+18 - 32V DC)
Pin 2 M1 (ground)
Pin 1 M2 (ground)
Pin 2 L2+ (+18 - 32V DC)
Warning
The SCALANCE X101-1 device is designed for operation with safety extra-low voltage. This
means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit to supply SCALANCE X101-1 must comply with NEC Class 2 (voltage
range 18-32 V, current requirement 200 mA).
If the device is connected to a redundant power supply (two separate power supplies), both
must meet these requirements.
The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low
voltage (SELV), DC 24 V).
Signaling Contact
The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact
(optical relay contact) is a floating switch with which error/fault states are signaled by contact
separation.
Figure 4-5 Signaling contact SCALANCE X101-1 Figure 4-6 Connector pinout
Pin number Pinout
Pin 1 F1
Pin 2 F2
If an empty fault mask (no port is monitored) is set or is to be set, the 2 port LEDs flash
alternatingly.
Simultaneously with the fault mask, the monitoring of the connected power supply is set. The
existence of the two power supply units is only monitored if both power supplies are
connected during saving the fault mask.
The failure of the link on a monitored port or of one of the monitored power supplies is
indicated by the illuminated red error LED. The signaling contact is opened simultaneously.
Note
The factory default is no port monitoring but monitoring of the power supply L1+/M1. If
necessary, error LED and signaling contact have to be cleared by pressing the button for an
appropriate period or the feeding point has to be changed when connecting only one power
supply to L2+/M2.
If you cascade two media converters, i.e. connect the converters via the FO port, it is
mandatory to previously activate this operating mode using the button. Keep the button
pressed for 1-2 seconds. After releasing, the acceptance of the operating mode is indicated
by the illuminated “TL” (transparent link) LED. Again press the button for 1-2 seconds to exit
this operating mode. The “TL” LED is extinguished.
Important notes:
• Max. two media converters can be cascaded
• mixed cascading with SCALANCE X-100 Media converter and OMC-Media
converter is not possible
• The cascade connection is only permitted via the connection of the FO ports!
• It is mandatory that a cascade connection is set at both (!) media converters using
the button (“ TL” LED must be illuminated). If this is not done, malfunctions can
occur.
• The setting remains after turning on/off.
• The factory setting is “ stand-alone mode” , i.e. no cascade is set
Status Meaning
Lit red SCALANCE X101-1 detects an error. Simultaneously the
signaling contact opens.
The following errors are detected:
1. Link down event at a monitored port.
2. Failure of the supply voltage or supply voltage less than
14 V of one of the two redundant power supplies. See also
note in chapter 4.2.7
Not lit No error was detected by SCALANCE X101-1.
Status Meaning
Lit green Power supply L1 or L2 are connected.
Not lit Power supply L1 and L2 is not connected or L1 and L2 <14 V
Comment: If the green LED is not lit, no other signal LED is lit.
Status Meaning
Port 1: LED lit green link exists, no data reception at TP port
Port 2: LED lit green link exists, no data reception at FOC
Port 1: LED lit yellow link exists, data received at TP port
Port 2: LED lit yellow link exists, data received at FOC port
Port 1 and 2: LEDs flash yellow Setting or display of the fault mask
Note
The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if
both ports have link at the same time.
In transparent link mode the link state is also recognized and indicated by the optical
port(P2) without a link at the port P1 (see chapter 4.2.8).
Status Meaning
Lit green Transparent link parameterized.
Not lit Stand-alone mode. DTEs are connected to both ports of the
media converter (no cascading)
See chapter 4.2.8 "Important notes"!
Ports
Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 100 Mbps
twisted pair full duplex
Connection of further network components over 2 BFOC sockets
FOC (100 Mbps, full duplex to 100 BaseFX)
Connector for power supply 1x4-pin plug-in terminal block
Connector for signaling contact 1x2-pin plug-in terminal block
Electrical Data
Power supply 2 x DC 24 V
(DC 18 - 32 V)
safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.) 3W
Current consumption at rated voltage (typ.) 120 mA
Minimum rated current of the power supply 170 mA
Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V)
Permitted Cable Lengths
Network span parameter/TP cable length
0 – 100 m IE FC TP standard cable with IE FC RJ-45
plug 180
or
IE FC outlet RJ-45 with IE FC TP standard cable
(0 - 90 m) + 10 m TP cord
0 – 85 m IE FC TP marine/trailing/flexible with IE FC RJ-45
plug 180
or
IE FC TP marine/trailing/flexible (0 – 75 m) + 10
m TP cord over IE FC outlet RJ-45
3
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
Order Numbers
SCALANCE X101-1 6GK5101-1BB00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0
manual
IE FC stripping tool 6GK1901-1GA00
IE FC blade cassettes 6GK1901-1GB00
IE FC TP standard cable GP 6XV1840 2AH10
IE FC TP trailing cable 6XV1840-3AH10
IE FC TP marine cable 6XV1840-4AH10
IE FC TP trailing cable GP 6XV1870-2D
IE FC TP flexible cable GP 6XV1870-2B
IE FC RJ-45 plug 180 pack of 1 6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10 6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50 6GK1 901-1BB10-2AE0
Note
The number of SCALANCE X Industrial Ethernet devices connected in a line influences the
frame propagation time.
When a frame passes through the media converters of the SCALANCE X-100 series, it is
typically delayed by approx. 8µs by the “Cut Through” function of the internal switch
- At a network load of 100% these times can increase system-dependently (max. 140 µs)
Unpacking, Checking
1. Make sure that the package is complete.
2. Check all parts for transport damage.
Warning
Do not use any parts that show evidence of damage!
Warning
If the SCALANCE X101-1FL device is operated in ambient temperatures between 55°C-
60°C, the temperature of the device housing may be higher than 70°C.
The subject unit must be located in a Restricted Access Location where access can only
be gained by SERVICE PERSONNEL or by USERS who have been instructed about the
reasons for the restrictions applied to the location and about any precautions that shall be
taken when operated in an ambient temperature of 55°C-60°C .
Possible Attachments
The SCALANCE X101-1FL media converter features an RJ-45 jack and a BFOC port for the
connection of DTEs or other network segments.
Note
The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket
Connector Pinout
RJ-45 jack
On SCALANCE X101-1FL, the twisted pair port is implemented as RJ-45 jack with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Notice
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP
port.
Depending on the cable type, a total cable length of up to 100 m is permitted between two
devices with the IE FC cables and IE FC RJ-45 plug 180.
Note
The SCALANCE X101-1FL works with a fixed transmission speed of 10 Mbps in half duplex.
Devices not supporting autonegotiation must be set to 10 Mbps half duplex.
Note
Autopolarity is not support by the SCALANCE X101-1FL.
Transmission Speed
The transmission rate of the optical Ethernet port is 10 Mbps.
Note
The SCALANCE X101-1FL works with a fixed transmission speed of 10 Mbps in half duplex.
Transmission Mode
The transmission mode for 10Base-FL is specified in the IEEE 802.3 standard.
Since the half duplex mode and the transmission rate cannot be modified for optical
transmission, autonegotiation cannot be applied.
Transmission Medium
The data are transferred over multimode fiber-optic cable (FOC). The transceiver wavelength
is 820 nm.
Multimode fiber-optic cables are used with a core diameter of 50 or 62.5 µm, the light source
is an LED.
The outer diameter of the FOC is 125 µm.
Range
The maximum transmission range (segment length) is 3 km if the signal attenuation of the
FOC is ≤ 3 dB/km at 850 nm.
Connectors
The cables are connected to BFOC sockets.
Power Supply
The power supply is connected using a 4-pin plug-in terminal block. The power supply can
be connected redundantly. Both inputs are isolated. There is no distribution of load. When
using a redundant power supply, the power supply unit with the higher output voltage
supplies SCALANCE X101-1FL alone. The power supply is connected over a high
resistance with the enclosure to allow an ungrounded setup.
Figure 4-9 Power supply SCALANCE X101-1FL Figure 4-10 Connector pinout
Pin number Pinout
Pin 1 L1+ (+18 - 32V DC)
Pin 2 M1 (ground)
Pin 1 M2 (ground)
Pin 2 L2+ (+18 - 32V DC)
Warning
The SCALANCE X101-1FL device is designed for operation with safety extra-low voltage.
This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit to supply SCALANCE X101-1FL must comply with NEC Class 2
(voltage range 18-32 V, current requirement 200 mA).
If the device is connected to a redundant power supply (two separate power supplies), both
must meet these requirements.
The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low
voltage (SELV), DC 24 V).
Never connect SCALANCE X101-1FL to AC voltage.
Never operate SCALANCE X101-1FL with DC voltage higher than 32 V DC.
Signaling Contact
The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact
(optical relay contact) is a floating switch with which error/fault states are signaled by contact
separation.
Figure 4-11 Signaling contact SCALANCE X101-1FL Figure 4-12 Connector pinout
Pin number Pinout
Pin 1 F1
Pin 2 F2
Note
The factory default is no port monitoring but monitoring of the power supply L1+/M1. If
necessary, error LED and signaling contact have to be cleared by pressing the button for an
appropriate period or the feeding point has to be changed when connecting only one power
supply to L2+/M2.
If you cascade two media converters, i.e. connect the converters via the FO port, it is
mandatory to previously activate this operating mode using the button. Keep the button
pressed for 1-2 seconds. After releasing, the acceptance of the operating mode is indicated
by the illuminated “TL” (transparent link) LED. Again press the button for 1-2 seconds to exit
this operating mode. The “TL” LED is extinguished.
Important notes:
• Max. two media converters can be cascaded
• mixed cascading with SCALANCE X-100 Media converter and OMC-Media
converter is not possible
• The cascade connection is only permitted via the connection of the FO ports!
• It is mandatory that a cascade connection is set at both (!) media converters using
the button (“ TL” LED must be illuminated). If this is not done, malfunctions can
occur.
• The setting remains after turning on/off.
• The factory setting is “ stand-alone mode” , i.e. no cascade is set
Status Meaning
Lit red SCALANCE X101-1FL detects an error. Simultaneously the
signaling contact opens.
The following errors are detected:
1. Link down event at a monitored port.
2. Failure of the supply voltage or supply voltage less than
14 V of one of the two redundant power supplies. See also
note in chapter 4.3.7
Not lit No error was detected by SCALANCE X101-1FL.
Status Meaning
Lit green Power supply L1 or L2 are connected.
Not lit Power supply L1 and or L2 is not connected or L1 and L2 <14 V
Comment: If the green LED is not lit, no other signal LED is lit.
Status Meaning
Port 1: LED lit green link exists, no data reception at TP port
Port 2: LED lit green link exists, no data reception at FOC
Port 1: LED lit yellow link exists, data received at TP port
Port 2: LED lit yellow link exists, data received at FOC port
Port 1 and 2: LEDs flash yellow Setting or display of the fault mask
Note
The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if
both ports have link at the same time.
Status Meaning
Not lit Stand-alone mode. DTEs are connected to both ports of the
media converter (no cascading)
A direct cascade connection of two SCALANCE X101-1FL media converters is not possible,
thus no transparent link.
Ports
Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 10 Mbps
twisted pair half duplex
Connection of further network components over 2 BFOC sockets
FOC (10 Mbps, half duplex to 10 BaseFL)
Connector for power supply 1x4-pin plug-in terminal block
Connector for signaling contact 1x2-pin plug-in terminal block
Electrical Data
Power supply 2 x DC 24 V
(DC 18 - 32 V)
safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.) 3W
Current consumption at rated voltage (typ.) 120 mA
Minimum rated current of the power supply 200 mA
Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V)
Permitted Cable Lengths
Network span parameter/TP cable length
0 – 100 m IE FC TP standard cable with IE FC RJ-45 plug
180
or
IE FC outlet RJ-45 with IE FC TP standard cable
(0 - 90 m) + 10 m TP cord
0 – 85 m IE FC TP marine/trailing/flexible with IE FC RJ-45
plug 180
or
IE FC TP marine/trailing/flexible (0 – 75 m) + 10
m TP cord over IE FC outlet RJ-45
4
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
Order Numbers
SCALANCE X101-1FL 6GK5101-1BY00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0
manual
IE FC stripping tool 6GK1901-1GA00
IE FC blade cassettes 6GK1901-1GB00
IE FC TP standard cable GP 6XV1840 2AH10
IE FC TP trailing cable 6XV1840-3AH10
IE FC TP marine cable 6XV1840-4AH10
IE FC TP trailing cable GP 6XV1870-2D
IE FC TP flexible cable GP 6XV1870-2B
IE FC RJ-45 plug 180 pack of 1 6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10 6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50 6GK1 901-1BB10-2AE0
Note
The number of SCALANCE X Industrial Ethernet devices connected in a line influences the
frame propagation time.
When a frame passes through the media converters of the SCALANCE X-100 series, it is
typically delayed by approx. 40 µs by the “Cut Through” function of the internal switch
- At a network load of 100%, these times can increase system-dependently (max. 180 µs)
Unpacking, Checking
1. Make sure that the package is complete.
2. Check all parts for transport damage.
Warning
Do not use any parts that show evidence of damage!
Warning
If the SCALANCE X101-1LD device is operated in ambient temperatures between 55°C-
60°C, the temperature of the device housing may be higher than 70°C.
The subject unit must be located in a Restricted Access Location where access can only
be gained by SERVICE PERSONNEL or by USERS who have been instructed about the
reasons for the restrictions applied to the location and about any precautions that shall be
taken when operated in an ambient temperature of 55°C-60°C.
Possible Attachments
The media converter of SCALANCE X101-1LD features an RJ-45 jack and a BFOC port for
the connection of DTEs or other network segments.
Note
The BFOC socket (Bayonet Fiber Optic Connector) corresponds to the ST socket
Connector pinout
RJ-45 jack
On SCALANCE X101-1LD, the twisted pair port is implemented as RJ-45 jack with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Notice
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP
port.
Depending on the cable type, a total cable length of up to 100 m is permitted between two
devices with the IE FC cables and IE FC RJ-45 plug 180.
Autonegotiation
Autonegotiation means the automatic detection of the functionality of the port at the opposite
end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the
port of a partner device allowing automatic configuration of different types of device. With
autonegotiation, two components connected to a link segment can exchange parameters
and set themselves to match the supported communication functionality.
Note
Devices not supporting autonegotiation must be set to 100 Mbps/ half duplex.
Transmission Speed
The transmission rate of the optical Fast Ethernet port is 100 Mbps.
Transmission Mode
The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard.
Since the full duplex mode and the transmission rate cannot be modified for optical
transmission, autonegotiation cannot be applied.
Transmission Medium
The data are transferred over monomode fiber-optic cable (FOC). The transceiver
wavelength is 1310 nm.
Monomode fiber-optic cables are used with a core diameter of 10 µm. The outer diameter of
the FOC is 125 µm.
Source
The light source is an “eye-safe” Class1 laser with a wavelength of 1310 nm
Range
The maximum transmission range (segment length) is 26 km if the signal attenuation of the
FOC is ≤ 0.5 dB/km.
Connectors
The cables are connected to BFOC sockets.
Power Supply
The power supply is connected using a 4-pin plug-in terminal block. The power supply can
be connected redundantly. Both inputs are isolated. There is no distribution of load. When
using a redundant power supply, the power supply unit with the higher output voltage
supplies SCALANCE X101-1LD alone. The power supply is connected over a high
resistance with the enclosure to allow an ungrounded setup.
Figure 4-15 Power supply SCALANCE X101-1LD Figure 4-16 Connector pinout
Pin number Pinout
Pin 1 L1+ (+18 - 32V DC)
Pin 2 M1 (ground)
Pin 1 M2 (ground)
Pin 2 L2+ (+18 - 32V DC)
Warning
The SCALANCE X101-1LD device is designed for operation with safety extra-low voltage.
This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit to supply SCALANCE X101-1LD must comply with NEC Class 2
(voltage range 18-32 V, current requirement 200 mA).
If the device is connected to a redundant power supply (two separate power supplies), both
must meet these requirements.
The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low
voltage (SELV), DC 24 V).
Never connect SCALANCE X101-1LD to AC voltage.
Never operate SCALANCE X101-1LD with DC voltage higher than 32 V DC.
Signaling Contact
The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact
(optical relay contact) is a floating switch with which error/fault states are signaled by contact
separation.
Figure 4-17 Signaling contact SCALANCE X101-1LD Figure 4-18 Connector pinout
Pin number Pinout
Pin 1 F1
Pin 2 F2
Note
The factory default is no port monitoring but monitoring of the power supply L1+/M1. If
necessary, error LED and signaling contact have to be cleared by pressing the button for an
appropriate period or the feeding point has to be changed when connecting only one power
supply to L2+/M2.
If you cascade two media converters, i.e. connect the converters via the FO port, it is
mandatory to previously activate this operating mode using the button. Keep the button
pressed for 1-2 seconds. After releasing, the acceptance of the operating mode is indicated
by the illuminated “TL” (Transparent Link) LED. Again press the button for 1-2 seconds to
exit this operating mode. The “TL” LED is extinguished.
Important notes:
• Max. two media converters can be cascaded
• mixed cascading with SCALANCE X-100 Media converter and OMC-Media
converter is not possible
• The cascade connection is only permitted via the connection of the FO ports!
• It is mandatory that a cascade connection is set at both (!) media converters using
the button (“ TL” LED must be illuminated). If this is not done, malfunctions can
occur.
• The setting remains after turning on/off.
• The factory setting is “ stand-alone mode” , i.e. no cascade is set
Status Meaning
Lit red SCALANCE X101-1LD detects an error. Simultaneously the
signaling contact opens.
The following errors are detected:
1. Link down event at a monitored port.
2. Failure of the supply voltage or supply voltage less than
14 V of one of the two redundant power supplies. See also
note in chapter 4.4.7
Not lit No error was detected by SCALANCE X101-1LD.
Status Meaning
Lit green Power supply L1 or L2 are connected.
Not lit Power supply L1 and or L2 is not connected or L1 and L2 <14 V
Comment: If the green LED is not lit, no other signal LED is lit.
Status Meaning
Port 1: LED lit green link exists, no data reception at TP port
Port 2: LED lit green link exists, no data reception at FOC
Port 1: LED lit yellow link exists, data received at TP port
Port 2: LED lit yellow link exists, data received at FOC port
Port 1 and 2: LEDs flash yellow Setting or display of the fault mask
Note
The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if
both ports have link at the same time.
In transparent link mode the link state is also recognized and indicated by the optical
port(P2) without a link at the port P1 (see chapter 4.4.8).
Status Meaning
Lit green Transparent link parameterized.
Not lit Stand-alone mode. DTEs are connected to both ports of the
media converter (no cascading)
See chapter 4.4.8 "Important notes"!
Ports
Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 100 Mbps
twisted pair full duplex
Connection of further network components over 2 BFOC sockets
FOC (100 Mbps, full duplex to 100 BaseFX)
Connector for power supply 1x4-pin plug-in terminal block
Connector for signaling contact 1x2-pin plug-in terminal block
Electrical Data
Power supply 2 x DC 24 V
(DC 18 - 32 V)
safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.) 3W
Current consumption at rated voltage (typ.) 120 mA
Minimum rated current of the power supply 200 mA
Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V)
Permitted Cable Lengths
Network span parameter/TP cable length
0 – 100 m IE FC TP standard cable with IE FC RJ-45 plug
180
or
IE FC outlet RJ-45 with IE FC TP standard cable
(0 - 90 m) + 10 m TP cord
0 – 85 m IE FC TP marine/trailing/flexible with IE FC RJ-45
plug 180
or
IE FC TP marine/trailing/flexible (0 – 75 m) + 10
m TP cord over IE FC outlet RJ-45
5
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
Order Numbers
SCALANCE X101-1LD 6GK5101-1BC00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0
manual
IE FC stripping tool 6GK1901-1GA00
IE FC blade cassettes 6GK1901-1GB00
IE FC TP standard cable GP 6XV1840 2AH10
IE FC TP trailing cable 6XV1840-3AH10
IE FC TP marine cable 6XV1840-4AH10
IE FC TP trailing cable GP 6XV1870-2D
IE FC TP flexible cable GP 6XV1870-2B
IE FC RJ-45 plug 180 pack of 1 6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10 6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50 6GK1 901-1BB10-2AE0
Note
The number of SCALANCE X Industrial Ethernet devices connected in a line influences the
frame propagation time.
When a frame passes through the media converters of the SCALANCE X-100 series, it is
typically delayed by approx. 8µs by the “Cut Through” function of the internal switch
- At a network load of 100% these times can increase system-dependently (max. 140 µs)
Unpacking, Checking
1. Make sure that the package is complete.
2. Check all parts for transport damage.
Warning
Do not use any parts that show evidence of damage!
Warning
If the SCALANCE X101-1POF device is operated in ambient temperatures between
55°C-60°C, the temperature of the device housing may be higher than 70°C.
The subject unit must be located in a Restricted Access Location where access can only
be gained by SERVICE PERSONNEL or by USERS who have been instructed about the
reasons for the restrictions applied to the location and about any precautions that shall be
taken when operated in an ambient temperature of 55°C-60°C.
Possible Attachments
The media converter of SCALANCE X101-1POF features an RJ-45 jack and an SC-RJ
interface for the connection of DTEs or other network segments.
Connector pinout
RJ-45 jack
On SCALANCE X101-1POF, the twisted pair port is implemented as RJ-45 jack with MDI-X
assignment (Medium Dependent Interface–Autocrossover) of a network component.
Notice
TP cords or TP-XP cords with a maximum length of 10 m can be connected to the RJ-45 TP
port.
Depending on the cable type, a total cable length of up to 100 m is permitted between two
devices with the IE FC cables and IE FC RJ-45 plug 180.
Autonegotiation
Autonegotiation means the automatic detection of the functionality of the port at the opposite
end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the
port of a partner device allowing automatic configuration of different types of device. With
autonegotiation, two components connected to a link segment can exchange parameters
and set themselves to match the supported communication functionality.
Note
Devices not supporting autonegotiation must be set to 100 Mbps / half duplex.
Transmission Speed
The transmission rate of the optical Fast Ethernet port is 100 Mbps.
Transmission Mode
The transmission mode for 100Base-FX is specified in the IEEE 802.3 standard.
Since the full duplex mode and the transmission rate cannot be modified for optical
transmission, autonegotiation cannot be applied.
Transmission Medium
The data are transferred over plastic optical fiber cable (FOC). The wavelength is 650 nm.
Plastic optical fiber cables are used with a core diameter of 980 µm, the light source is an
LED.
The outer diameter of the FOC is 1000 µm.
Range
The maximum transmission range (segment length) is 50 m if the signal attenuation of the
FOC is ≤ 0.23 dB/m.
Connectors
The cables are connected to SC-RJ sockets.
Power Supply
The power supply is connected using a 4-pin plug-in terminal block. The power supply can
be connected redundantly. Both inputs are isolated. There is no distribution of load. When
using a redundant power supply, the power supply unit with the higher output voltage
supplies SCALANCE X101-1POF alone. The power supply is connected over a high
resistance with the enclosure to allow an ungrounded setup.
Figure 4-21 Power supply SCALANCE X101-1POF Figure 4-22 Connector pinout
Pin number Pinout
Pin 1 L1+ (+18 - 32V DC)
Pin 2 M1 (ground)
Pin 1 M2 (ground)
Pin 2 L2+ (+18 - 32V DC)
Warning
The SCALANCE X101-1POF device is designed for operation with safety extra-low voltage.
This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/
VDE0805 can be connected to the power supply terminals.
The power supply unit to supply SCALANCE X101-1POF must comply with NEC Class 2
(voltage range 18-32 V, current requirement 200 mA).
If the device is connected to a redundant power supply (two separate power supplies), both
must meet these requirements.
The signaling contact can be subjected to a maximum load of 100 mA (safety extra-low
voltage (SELV), DC 24 V).
Never connect SCALANCE X101-1POF to AC voltage.
Never operate SCALANCE X101-1POF with DC voltage higher than 32 V DC.
Signaling Contact
The signaling contact is connected to a 2-pin plug-in terminal block. The signaling contact
(optical relay contact) is a floating switch with which error/fault states are signaled by contact
separation.
Figure 4-23 Signaling contact SCALANCE X101-1POF Figure 4-24 Connector pinout
Pin number Pinout
Pin 1 F1
Pin 2 F2
Note
The factory default is no port monitoring but monitoring of the power supply L1+/M1. If
necessary, error LED and signaling contact have to be cleared by pressing the button for an
appropriate period or the feeding point has to be changed when connecting only one power
supply to L2+/M2.
If you cascade two media converters, i.e. connect the converters via the FO port, it is
mandatory to previously activate this operating mode using the button. Keep the button
pressed for 1-2 seconds. After releasing, the acceptance of the operating mode is indicated
by the illuminated “TL” (Transparent Link) LED. Again press the button for 1-2 seconds to
exit this operating mode. The “TL” LED is extinguished.
Important notes:
• Max. two media converters can be cascaded
• mixed cascading with SCALANCE X-100 Media converter and OMC-Media
converter is not possible
• The cascade connection is only permitted via the connection of the FO ports!
• It is mandatory that a cascade connection is set at both (!) media converters using
the button (“ TL” LED must be illuminated). If this is not done, malfunctions can
occur.
• The setting remains after turning on/off.
• The factory setting is “ stand-alone mode” , i.e. no cascade is set
Status Meaning
Lit red SCALANCE X101-1POF detects an error. Simultaneously the
signaling contact opens.
The following errors are detected:
1. Link down event at a monitored port.
2. Failure of the supply voltage or supply voltage less than
14 V of one of the two redundant power supplies. See also
note in chapter.4.5.7
Not lit No error was detected by SCALANCE X101-1POF.
Status Meaning
Lit green Power supply L1 or L2 are connected.
Not lit Power supply L1 and or L2 is not connected or L1 and L2 <14 V
Comment: If the green LED is not lit, no other signal LED is lit.
Status Meaning
Port 1: LED lit green link exists, no data reception at TP port
Port 2: LED lit green link exists, no data reception at FOC
Port 1: LED lit yellow link exists, data received at TP port
Port 2: LED lit yellow link exists, data received at FOC port
Port 1 and 2: LEDs flash yellow Setting or display of the fault mask
Note
The link state of port P1 and port P2 (LED lit green) in stand-alone-mode is only indicated if
both ports have link at the same time.
In transparent link mode the link state is also recognized and indicated by the optical
port(P2) without a link at the port P1 (see chapter 4.5.8).
Status Meaning
Lit green Transparent link parameterized.
Not lit Stand-alone mode. DTEs are connected to both ports of the
media converter (no cascading)
See chapter 4.5.8 "Important notes"!
Ports
Attachment of DTEs or network components over 1xRJ-45 socket with MDI-X pinning 100 Mbps
twisted pair full duplex
Connection of further network components over 2 SC-RJ sockets
FOC (100 Mbps, full duplex to 100 BaseFX)
Connector for power supply 1x4-pin plug-in terminal block
Connector for signaling contact 1x2-pin plug-in terminal block
Electrical Data
Power supply 2 x DC 24 V
(DC 18 - 32 V)
safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.) 3W
Current consumption at rated voltage (typ.) 120 mA
Minimum rated current of the power supply 200 mA
Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V)
Permitted Cable Lengths
Network span parameter/TP cable length
0 – 100 m IE FC TP standard cable with IE FC RJ-45 plug
180
or
IE FC outlet RJ-45 with IE FC TP standard cable
(0 - 90 m) + 10 m TP cord
0 – 85 m IE FC TP marine/trailing/flexible with IE FC RJ-45
plug 180
or
IE FC TP marine/trailing/flexible (0 – 75 m) + 10
m TP cord over IE FC outlet RJ-45
6
Temperature code "T.." and maximum ambient temperature "Ta: .." as indicated on marking plate
Order Numbers
SCALANCE X101-1POF 6GK5101-1BH00-2AA3
"Industrial Ethernet TP and Fiber Optic Networks" 6GK1970-1BA10-0AA0
manual
IE FC stripping tool 6GK1901-1GA00
IE FC blade cassettes 6GK1901-1GB00
IE FC TP standard cable GP 6XV1840 2AH10
IE FC TP trailing cable 6XV1840-3AH10
IE FC TP marine cable 6XV1840-4AH10
IE FC TP trailing cable GP 6XV1870-2D
IE FC TP flexible cable GP 6XV1870-2B
IE FC RJ-45 plug 180 pack of 1 6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10 6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50 6GK1 901-1BB10-2AE0
Note
The number of SCALANCE X Industrial Ethernet devices connected in a line influences the
frame propagation time.
When a frame passes through the media converters of the SCALANCE X-100 series, it is
typically delayed by approx. 8µs by the “Cut Through” function of the internal switch
- At a network load of 100% these times can increase system-dependently (max. 140 µs)
Types of Installation
The media converters of the SCALANCE X-100 series can be mounted in different ways:
• Installation on a 35 mm DIN rail
• Installation on a SIMATIC S7-300 DIN rail
• Wall mounting
Note
When installing and operating the device, keep to the installation instructions and safety-
related notices as described here and in the SIMATIC NET Industrial Ethernet Twisted Pair
and Fiber Optic Networks /2/ manual.
Warning
If the cable or conduit entry point exceeds 70°C or the branching point of conductors
exceeds 80°C special precautions must be taken. If the equipment is operated in an air
ambient of 50°C - 60 °C, only use cables with admitted maximum operating temperature of
at least 80°C.
Warning
Provisions shall be made to prevent the rated voltage from being exceeded by transient
disturbances of more than 40%. This criteria is fulfilled, if supplies are derived from SELV
(Safety Extra Low Voltage), only.
Installation
Install the media converter on a 35 mm DIN rail according to DIN EN 50022.
1. Place the upper catch of the device over the top of the rail and then push in the lower part
of the device against the rail until it clips into place.
2. Install the electrical connecting cables and the terminal block for the signaling contact.
3. Fit the connectors for the power supply and the signaling contact into the sockets on the
device.
Uninstalling
To remove the media converter from the DIN rail:
1. First disconnect the TP cable and the FO cables. Remove the terminal block for the
power supply and the signaling contact.
2. Use a screwdriver to release the lower rail catch of the device and pull the lower part
of the device away from the rail.
Uninstalling
To remove the media converters of the SCALANCE X-100 series from the SIMATIC S7-300
DIN rail:
1. First disconnect all connected cables.
2. Loosen the screws on the underside of the DIN rail and lift the device away from the DIN
rail.
Wall Mounting
1. Use four wall plugs (6 mm diameter and 30 mm long).
2. To attach the device, use screws with a diameter of 3.5 mm and a length of 40 mm.
3. Note the drilling templates in chapter 8 Dimension Drawings.
Note
The wall mounting must be capable of supporting at least four times the weight of the
device.
5.2 Grounding
S7 DIN Rail
The device is grounded over its rear panel and the neck collar screw.
Wall Mounting
The device is grounded by the securing screw in the unpainted hole.
Please note that the media converter of the SCALANCE X-100 series must be grounded
over one securing screw with minimum resistance.
If a device of the SCALANCE X100 product line is mounted on a non-conducting base, a
grounding cable must be installed. The grounding cable is not supplied with the device.
Connect the paint-free surface of the device to the nearest grounding point using the
grounding cable.
Assemble the IE FC RJ-45 plug 180 and the IE FC standard cable as follows
For information on the assembly, please refer to the instructions that ship with the IE FC
RJ-45 plug 180.
The robust connectors of the nodes are designed for industry and are PROFINET-compliant.
Due to the locking mechanism on the casing, they provide additional strain and torsion relief.
Due to the closing shape and the latching with the PROFINET-compliant connector IE FC
RJ-45 plug 180, the sleeve at the TP port of the media converter of the SCALANCE X-100
series ensures a robust, industry-standard node connection which provides additional strain
and torsion relief of the twisted pair port.
If, for lack of space, a manual unlatching is not possible, you can also unlatch the plug with a
2.5 mm screwdriver. Subsequently you can remove the IE FC RJ-45 plug 180 from the
twisted pair port.
5.4 Maintenance
Maintenance
The devices of the product lines SCALANCE X-100 and X-200 are equipped with a self-
resetting fuse (resettable fuse / PTC). If the fuse blows (all LEDs are off despite correctly
applied power supply), the device should be disconnected from the power supply for approx.
30 minutes before it can be turned on again.
If any different fault develops, please send the device to your SIEMENS service center for
repair. Repairs on-site are not possible.
Product Name
EMC Directive
89/336/EEC "Electromagnetic Compatibility"
Area of Application
The products are designed for use in an industrial environment:
Installation Guidelines
The products meet the requirements if you keep to the installation instructions and safety-
related notices as described here and in the manual SIMATIC NET Industrial Ethernet
Twisted Pair and Fiber Optic Networks /1/ when installing and operating the device.
Conformity Certificates
The EU declaration of conformity is available for the responsible authorities according to the
above-mentioned EU directive at the following address:
Siemens Aktiengesellschaft
Bereich Automatisierungs- und Antriebstechnik
Industrielle Kommunikation (A&D PT2)
Postfach 4848
D-90327 Nürnberg
AUI
Attachment Unit Interface. 10 Mbps TP port (15-pin sub D) for connecting an AUI drop cable.
Can be implemented either as DTE (data terminal equipment) or as DCE (data carrier
equipment). Is primarily used for the connection to triax segments.
Autocrossover
Method with which a TP port is automatically switched between MDI and MDI-X assignment
to establish a connection independently of the port assignment of the device to be
connected. This ensures that crossover cables are not required. The autocrossover function
requires that the respective port is set to autonegotiation mode.
Autonegotiation
A technique standardized according to IEEE 802.3 with which the transmission parameter
(e.g. 10/100 Mbps, full / half duplex) is automatically negotiated between devices.
C-PLUG
The C-PLUG (configuration plug) is a swap medium for backing up the configuration data. If
the device is replaced, the configuration can be applied by exchanging the C-PLUG.
CRC
Cyclic Redundancy Check. A checksum used in transmission protocols to detect errors in
frames.
Cut Through
With this method, a frame is forwarded as soon as the destination address is recognized.
Therefore the delay does not depend on the frame length. However, if there are problems in
a network, also defective frames are forwarded which may increase the network load.
Event
for alarms & events: An event is any incident that could be of interest to a client. Although
events can also be generated when a condition is met, it is not necessary that they are
linked to a condition. Events not linked to conditions include e.g. error messages of the
communication system.
Fault Mask
Definition of a desired status (good status); deviations from this status during operation are
considered as errors/faults.
FO
Fiber optic
Monomode
The monomode fiber (also single-mode fiber) typically has a core diameter of 5 to 9 µm.
However, the outer diameter is also 125 µm. The actual transmission of the information takes
place in the core of the fiber.
Multicast
A frame with a multicast address is received by all recipients which are ready for receiving
this address.
Multimode
In multimode transmission, the pulse is transferred using many modes (waves) which travel
along curved paths or which are reflected within the core. Attenuation is mainly caused by
physical absorption and dispersion as well as by mechanical bending. Among other things,
the amount of attenuation depends on the wavelength of the input light. Multimode fiber-optic
cables have an outer diameter of 125 µm and a core diameter of 50 or 62.5 µm. Due to the
larger core diameter, the pulse edges degrade more than in single mode transmission, which
results in shorter transmission distances.
OSM
Optical Switching Module – SIMATIC NET Ethernet switch with optical ports.
Reconfiguration Time
Time required to restore a functional configuration in case of a device failure or an
interruption of a connection line.
Ring Port
Two ports in a switch via which it is connected with other switches to form a ring. One switch
in the ring must be configured as redundancy manager. This switch sends test frames via
the ring ports that are forwarded by all ring ports of other switches in the ring. This ensures
that the ring does not have any interruptions.
Segment
In the Ethernet bus system, the transceivers connected over the bus cable along with the
nodes connected over patch cables form a segment. Several such segments can be
connected via repeaters. When using twisted pair and fiber-optic cables, each subsection
forms one segment.
Signaling Contact
Floating relay contact via which detected error/fault states are signaled.
TP Port
Port with TP connector (RJ-45 jack)
A M
ATEX, 1-2, 2-2 MDI /MDIX autocrossover function
Autonegotiation SCALANCE X101-1, 4-5
SCALANCE X101-1, 4-4 SCALANCE X101-1LD, 4-29
SCALANCE X101-1LD, 4-28 MDI /MDIX Autocrossover function
SCALANCE X101-1POF, 4-40 SCALANCE X101-1FL, 4-17
SCALANCE X101-1POF, 4-41
B
N
Button
SCALANCE X101-1, 4-7 Network topology, 3-1
SCALANCE X101-1FL, 4-20 Ring topology, 3-2
SCALANCE X101-1LD, 4-32 Star topology, 3-2
SCALANCE X101-1POF, 4-44
O
C Optical star topology, 3-2
CE mark, 1-2
Class1 Laser, 4-29
Connector pinout P
SCALANCE X101-1, 4-4
Port status display (green/yellow LEDs)
SCALANCE X101-1FL, 4-16
SCALANCE X101-1POF, 4-45
SCALANCE X101-1LD, 4-28
Port status indicator (green/yellow LEDs)
SCALANCE X101-1POF, 4-40
SCALANCE X101-1, 4-9
C-Tick mark, 1-2
SCALANCE X101-1FL, 4-21
SCALANCE X101-1LD, 4-33
Possible Attachments
F SCALANCE X101-1, 4-3
Fault indicator (red LED) SCALANCE X101-1FL, 4-15
SCALANCE X101-1, 4-9 SCALANCE X101-1LD, 4-27
SCALANCE X101-1FL, 4-21 SCALANCE X101-1POF, 4-39
SCALANCE X101-1LD, 4-33 Power indicator (green LED)
SCALANCE X101-1POF, 4-45 SCALANCE X101-1, 4-9
FM mark, 1-2 SCALANCE X101-1FL, 4-21
Fuse, 5-8 SCALANCE X101-1LD, 4-33
SCALANCE X101-1POF, 4-45
Power supply
SCALANCE X101-1, 4-6
SCALANCE X101-1FL, 4-18
SCALANCE X101-1LD, 4-30
SCALANCE X101-1POF, 4-42
R
Ring topology, 3-2, 3-3
S
Signaling contact
SCALANCE X101-1, 4-7
SCALANCE X101-1FL, 4-19
SCALANCE X101-1LD, 4-31
SCALANCE X101-1POF, 4-43
T
TL display (green LED)
SCALANCE X101-1, 4-10
SCALANCE X101-1FL, 4-22
SCALANCE X101-1LD, 4-34
SCALANCE X101-1POF, 4-46
U
UL mark, 1-2