0% found this document useful (0 votes)
617 views1 page

H40 Rebar Welding Calculation

This document contains calculations to determine the required lap length for welding H40 rebar based on Eurocode 3 (EN-3) standards. It calculates the design shear strength and resistance per unit length of a 24mm fillet weld. Given a welding length of 200mm on each side, the total effective welding length is 352mm. This results in an anchorage force of 683.7kN which exceeds the required 628.3kN, therefore the lap length is sufficient. A diagram shows the lapping length configuration.

Uploaded by

cheeseonglaw
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
617 views1 page

H40 Rebar Welding Calculation

This document contains calculations to determine the required lap length for welding H40 rebar based on Eurocode 3 (EN-3) standards. It calculates the design shear strength and resistance per unit length of a 24mm fillet weld. Given a welding length of 200mm on each side, the total effective welding length is 352mm. This results in an anchorage force of 683.7kN which exceeds the required 628.3kN, therefore the lap length is sufficient. A diagram shows the lapping length configuration.

Uploaded by

cheeseonglaw
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

ZAP Foundation Pte. Ltd.

CALCULATION SHEET:

Design By: Yuqing


PROJECT: N111 Check By: NTP
Approved By: Ref:
SUBJECT: Weld Length Calculation (Lap Length) - EN-3 Date: 21-4-2023
Rev 00

Weld Length Calculation (Lap Length) - Based on EN-3(EURO CODE-3) FOR H40

Ultimate Tensile Strength of Steel F u: 500 N/mm2


(EN-3: EN1993,1-8,
Correlation Factor (ẞw): 1
Table 4.1 )
(EN-3: EN1993,Part1-1,
Partial safety factor for weld(gM2) : 1.25
Clause 6.1)
Size of Fillet weld (w): 24 mm
Throat thickness (a): 0.5w mm
Throat thickness (a): 12 mm

Bar size : H40


Area of one rebar: 1257 mm2

Max. tensile force


: 500 x 1257 = 628.3 kN

Fvw.d = F u/√3/(ẞw)/gM2
Design Shear Strength of Weld,:
= 500/√3 = 231 N/mm2
1.0/1.25

Design resistance of weld per unit length FwRd is given by FwRd = Fvw.da

= 231.21 x12
= 2774.57 N/mm
Welding provided Length (L) = 200 mm x 2 numbers

Effective weld length, (L - 2a) = 176 mm


Total effective welding length, L = 352 mm
Anchorage force, F = (FwRd x L X0.7) x10-3
= 683.7 kN > 628.3 kN OK!

Note:
Proposed anchorage length, Y = 600 mm welding length

a = 200 mm welding length


b = Samaller of 16 into bar dia (or)200mm interval without weld

Y = 2a + b
b = 200mm

A
lapping length
A

24 mm filled weld
one sided

SECTION A-A