0% found this document useful (0 votes)
10 views

Modo Recovery LiquiControl

Recuperación equipo Liqui control

Uploaded by

Marcelo Regalado
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
10 views

Modo Recovery LiquiControl

Recuperación equipo Liqui control

Uploaded by

Marcelo Regalado
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 3
LIQUID GOOEY eens) LCR.iQ SOFTWARE RECOVERY TON ReAzy LCR.iQ® Software Recovery Instructions Applies to LCR.iQ and MASTERLOAD.IQ registers oper sofety protocols while working on registers published at wowwLCmeter.com/manuals “always be sure to follow th 4. Ensure paper isin the printer and printer is property installed and ready to print. Tne (eee Cut the calibration seal wire (f applicable) and loosen the calibration screw using a 7/16 wrench unt the calibration ticket begins to print automatically "Tip: Be sure to keep the calibration ticket in a safe place throughout this process. 3. Power down the register | 4, Using a 3/16" allen wrench, remove the four screws in the outer comers of the front cover of the register and swing the door to the left to open the register. 5, Insert the MicroSD card (provided inthe kit) into the MicroSD card slot located on the upper left portion of the CPU board. (see figures 1 & 2, item A) ‘Tip: Be sure the SD Card is pushed fully in the sot untl you fee locking “lick” 6. Insert the red jumper (provided in the kit) onto the two jumper pins. (see figures 1 & 2, item B) 7. Power up the register. The register will boot up in "MAINTENANCE MODE" which will be clearly indicated on the screen (figure 3, image C). When the process is complete, the screen will then instruct you to "POWER DOWN FOR 30s’ (figure 3, image D).. 8. Power down the register for 30 seconds. 9. Remove both the MicroSD card and the red jumper. ‘© Tip: To remove the MicroSD card, itty press it inward to release the lock soring, then pul out into USB slot on the register. (see figure 4) 410. Insert USB drive (provided in the ki 41. Power up the register and allow it to boot up to the home (idle) screen. Figure 10 this service bulletin, please contact the Liquid Controls 1050, ENERGY Scanned with CamScanner t= NUN TY daa 74,0174 a Ke KO) ernie) Upgrading LCR.iQe Software with LCR.iQ Recovery Kit on LCR.IQ and MASTERLOAD.iQ registers 41) SAVE THE CURRENT CONFIGURATION: >This saves the curent settings on the register and allows you to easly reload the settings es t ‘atthe end ofthe upgrade process. a) Insert the provided USB drive into USB slot on the register. fi r hit b) Loosen the Calibration Screw to enter Calibration Mode, then navigate to the Main Menu > Setup Menu > Security and press Software Update, ——__, jemi “Tp: Be sure to keep the calibration teket that pins out forthe final stop ofthis process, B@B__srmsn_ ©) Select Save Configuration on the Software Update page. ———__ }) On the Save Configuration page, select File Name then enter the desired ‘name for this configuration. Then press OK button on the keypad. Tip: Dotout Destination shouldbe USB" and Configuration Sie shouldbe ‘UT —_—aa 4) Upon returning to the Save Configuration page, click Save. When you see “The Configuration was. successfully saved’, Click OK, then Close to return to the Software Update page. 2) UPDATE THE REGISTER SOFTWARE: 2) On the Software Update page, select Load files from USB. When successtully loaded, you will see a confirmation screen saying “File Load was successfur. Click “OK", and you will return to the Software Update Page. b) On the Software Update Page, select Install SR1000 Firmware, i) Select LiquidControls 81000 V: ed.deb ‘When “Digital Signature successfull verified...” appears, cick OK. )_ When “Are you sure you want fo install.” appears, cick Yes. iv) The register wl install the sofware then reboot. When “Maintenance Mode POWER DOWN FOR 30s” appears, the register will ower cycle on is ov ‘within 30 seconds Upon rebooting it wil display “The Main Processor firmware was loaded successfully’, then click OK. selec Install Main Processor Firmware again vi1/.00-signed deb as described just above in 2.bii~ 2.biv ‘you will see a screen that shows SYSTEM ALERT. The Memory is FR ALL. (this is normal fortis process) Press OK RITY>RESET REGIS ‘and press OK from the lst and press OK fask are you sure you want 0 Clear All setngs... Press YES theres an update to SR1010 sofware avaiable for your unt... would you lke ‘now? Press YES. The screen will show you that is it upgrading the \/O board itto complete (100%) Jsoftware is applied, the SUCCESS screen wil display and say thatthe VO board ‘successfully... Press OK gp: “Il your LCR IQs sotup wth SENSEIQ boards, please be sure to access the fist YO ‘of SENSEIQ boards installed. This wil completo the sofware upgrade for any installed wil perform this actvty lst if applicable. Scanned with CamScanner on | Ks sey LCR.iQ SOFTWARE RECOVERY TUE Lse G0 NO ES era CEI) 3) LOAD A SAVED CONFIGURATION 2) Navigate tothe Security screen: Main Menu > Setup Menu > Security then press Software Update on the bottom of screen i) Select Load Configuration on the Software Update page ))_Be sure Perform Clear All First is marked "Y ii) Select File Name, then scroll down tothe previously saved fle name, Click OK, then Load. iv)_The unt will display “The Configuration was successfully loaded!” Click OK, then Close, 4) RESET PULSER CALIBRATION AND FLOW DIRECTION Pec AF sReerencing the calibration ticket instep 1, locate ‘PULSES/[unt of measure. ae r b) Navigate to Main Menu > Setup Menu > Calibration ‘Sieur Me ne ust i) Select Pulses/unt of measure) Shae i))_Enterin the vale ingicated on your calibration ticket Sete ©) Confirm or Set your ow direction a = Navigate to Main Menu > Setup Menu > Meter > low Direction »MGumm Cama ') Confirm your ow direction located on the ticket (€ or) and select the appropriate ug’ setting on the register. gm Fine vite ; rose ai 5) Setup SENSEIQ boards 199 200 0.0 bf *Only if SENSEIQ expansion boards are installed A tu f ) Navigate to Main Menu > Setup Menu > /O Setup (te Ares o ’) Select ‘Number of SENSEIQ Boards” ji) Enter the number of expansion boards installed {6) Performing a Register Field “Clear All” *Only required if indicated by the registerin step 3 AND if you did not “Load a Saved Configuration” above. 1) Go to Main Menu>Satup Menu>Securty>Reset Reaister fields then Select Clear Al 1) “Are you sure? ~ cick "Yes" Ifyou have any questions or concerns related to this service bulletin, please contact the Liguld Controls Technical Support Team at: +1 (847) 295-1050. ENERGY eer Scanned with CamScanner

You might also like