0% found this document useful (0 votes)
59 views1 page

P4c02-Snw-Tv-Mec-Sgt-Sho-2010 - Ecs-Street Level Ducting Layout Key Plan-P4c02-Snw-Tv-Mec-Sgt-Sho-2011

This document appears to be an engineering drawing showing building plans and sections. It includes labels for various building components like floors, walls, shafts, and cutouts. Dimensions are provided for structural elements like a shaft that is 1.95 square meters. The drawing also references property development drawings and includes annotation numbers to call out details.

Uploaded by

Manoj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views1 page

P4c02-Snw-Tv-Mec-Sgt-Sho-2010 - Ecs-Street Level Ducting Layout Key Plan-P4c02-Snw-Tv-Mec-Sgt-Sho-2011

This document appears to be an engineering drawing showing building plans and sections. It includes labels for various building components like floors, walls, shafts, and cutouts. Dimensions are provided for structural elements like a shaft that is 1.95 square meters. The drawing also references property development drawings and includes annotation numbers to call out details.

Uploaded by

Manoj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

A
A A

A''
FFL 576.550 m
B B

P4C02-SNW-TV-MEC-SGT-SHO-2012
ATRIUM CUTOUT AS PER
PROPERTY DEVELOPMENT
DRAWINGS

C C
B

D D

³ ES-01.1
DN
³
B'
PL10.2
PHE SHAFT
E 1.95 m²
E

³ C
ESC-11
DN
DN
F F
ESC-12
DN
(Future Development)
SPACE FOR KIOSK

EXPANSION JOINT EXPANSION JOINT


G FFL 576.550 m G

MATCHLINE
03 04 05 06 07 08 09

H H

I I

B01 CSD P4D02-ACM-SV-PRM-SGT-DRP-5010

J B02 CRD P4D02-ACM-TV-MEC-SGT-DRP-2010 J


B02 ARCH P4D02-ACM-AR-PRM-SGT-GL-DRP-1100 (DTD.10.01.2022)
REVISION SERVICE REF. DRAWING NO.
REFERENCE DRAWING

NOTES: THE RESPONSIBILITY OF CONTROL, CHECK & VERIFICATION OF ACCURACY, CORRECTNESS, COMPLETENESS, COUNTER
1. PUBLIC AREA DIFFUSERS LOCATION AREA SUBJECT TO FALSE CEILING COORDINATION. INTEGRATION & FULL COMPLIANCE OF THE CONTRACT PROVISIONS IN RESPECT OF DESIGN, ANALYSIS AND
THIS DRAWING INCLUDING ITS DESIGN AND DETAILING HAS BEEN
PROOF CHECKED INDEPENDENTLY AND FOUND SUITABLE FOR
□ Proof checked & Approved by GC SIGNED BY PROJECT: PUNE METRO RAIL PROJECT
2. FCU LOCATION ARE INDICATIVE AND SUBJECT TO EQUIPMENT POSITIONING AND DRAWINGS RESTS WITH THE DETAILED DESIGN CONSULTANT / DETAILED DESIGN CONSULTANT & CONTRACTOR. THE EXECUTION PURPOSE AND IS RECOMMENDED FOR GFC / NO MAHARASHTRA The Orion Building, 1st Floor, Opposite Don Bosco
K COORDINATION.
IT IS CERTIFIED THAT THERE IS NO CHANGE IN THIS GFCD FROM THE ALREADY APPROVED CR DWG NO. ".................................REV......." APPROVED ON DATE ................ OBJECTION'.
□ Being Given No Objection METRO RAIL K
3. DRAIN POINT SHALL BE COMMUNICATED SEPARATELY AFTER CIVIL INTERFACING.
CORPORATION
Center, Near Saint Mira's Girls College, Koregaon
4. ALL SERVICE BOTTOMS ARE INDICATIVE AND SUBJECT TO 3D MODEL COORDINATION.
DD PROOF CONSULTANT □ Issued As Good For Construction. LTD. Park, Pune - 411001, MH, India
TVS & ECS CONTRACTOR

STRUCTURE
SIGN: SIGN: SIGN: SIGN: SIGN: SIGN: SIGN: SIGN: SIGN: DY. HOD
DATE: 30.09.2022 DATE: 30.09.2022 DATE: 30.09.2022 DATE: 30.09.2022 DATE: DATE: DATE: DATE: DATE:
CLIENT: MAHARASHTRA METRO RAIL CORPORATION LTD.
NAME: ATUL NAME: BALAJI NAME: SUMAN NAME: SANDESH NAME: NAME: --- NAME: --- NAME: --- NAME: --- LOCATION: SWARGATE_STATION
DRAWN BY DESIGN BY CHECKED BY APPROVED BY ACCEPTED BY REVIEWED BY (STRUCT. ENGG.) APPROVED BY (TEAM LEADER) REVIEWED BY APPROVED BY
HOD TITLE: ECS - STREET LEVEL DUCTING LAYOUT (SHEET 1 OF 2)
L SYSTRA-AECOM-EGIS-RITES L
B02 30.09.2022 REVISED AS PER CLIENT COMMENTS

AS PER CHANGE IN CONFIGURATION


STERLING & WILSON (GENERAL CONSULTANT TO PUNE
SCALE: 1:100 DATE: 30.09.2022 STATUS: ISSUED FOR APPROVAL REVISION NO:
B01 22.04.2022
METRO RAIL PROJECT) DRG NO:

REV NO
B00 14.08.2021

DATE
ISSUED FOR APPROVAL

DESCRIPTION SIGN
P4C02-SNW-TV-MEC-SGT-SHO-2011 B02
1 2 3 4 5 6 7 8 9 10 11 12 plot scale
15 16
TBA 50mm

You might also like