0% found this document useful (0 votes)
104 views2 pages

Avon Protection - Filter Selection Matrix - EN

The document is a filter selection matrix that compares different gas and particulate respirator filters across various criteria. It shows that filters have different approvals, classifications, protections offered, weights, breathing resistances, shelf lives, body styles, and thread types. For example, the CFP100 filter is NIOSH approved, offers protection against particulates, gases, and vaporized metals/acids, weighs 118g, and has a 10 year shelf life. The matrix allows comparison of filters to help select the right one for different applications and contaminants.

Uploaded by

s98460
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
104 views2 pages

Avon Protection - Filter Selection Matrix - EN

The document is a filter selection matrix that compares different gas and particulate respirator filters across various criteria. It shows that filters have different approvals, classifications, protections offered, weights, breathing resistances, shelf lives, body styles, and thread types. For example, the CFP100 filter is NIOSH approved, offers protection against particulates, gases, and vaporized metals/acids, weighs 118g, and has a 10 year shelf life. The matrix allows comparison of filters to help select the right one for different applications and contaminants.

Uploaded by

s98460
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

FILTER SELECTION MATRIX

FILTER CFP100 CTCF50 CBRNCF50 CBRNCF50CE MILCF50 GPCF50 FM61 FM61EU CSCF50

External Approvals NIOSH NIOSH NIOSH CE / UKCA

A2B2E2K1P3/ Mil Spec/


Classification P100 CS/CN/P100 CBRN Cap1 A1B2E1K1P3 Mil Spec Mil Spec CS/CN/P100
NBC/CBRN A1B2E1K1P3

Riot Agents Riot Agents Riot Agents Riot Agents Riot Agents Riot Agents
Odor Odor Odor Odor Odor Odor
Riot Agents Particulate Particulate Particulate Particulate Particulate Particulate Riot Agents
Protection Particulate Odor CBRN Agents CBRN Agents CBRN Agents CBRN Agents CBRN Agents CBRN Agents Odor
Particulate NBC Agents NBC Agents NBC Agents NBC Agents NBC Agents NBC Agents Particulate
ABEK Agents ABEK Agents ABEK Agents ABEK Agents ABEK Agents ABEK Agents
TICS TICS TICS TICS TICS TICS

Weight (typical) 118 g 154 g 365 g 365 g 338 g 236 g 156 g 230g 80 g

Breathing Resistance 15 mm H2O 20 mm H2O 45 mm H2O 45 mm H2O 45 mm H2O 40 mm H2O 22 mm H2O 37 mm H₂O 20 mm H2O
(typical) at 85 l/min at 85 l/min at 85 l/min at 85 l/min at 85 l/min at 85 l/min at 42.5 l/min at 80 l/min at 85 l/min

Induction Induction Induction Induction


Packing Poly Bag Foil Bag Foil Bag Foil Bag Poly Bag
Welded Package Welded Package Welded Package Welded Package

Shelf Life
10 years 5.5 years 5.5 years 5.5 years 10 years 5 years 5 years 10 years 5 years
(if left in packaging)

Filter Body Style Conformal Conformal Convertible Convertible** Conformal Conformal Conformal* Conformal* Conformal

Filter Thread Type 40 mm 40 mm 40 mm 40 mm 40 mm 40 mm Bayonet Bayonet 40 mm

*This filter has a bayonet fit specific to the FM50 mask and must be used as a pair. ** Removing the TCP invalidates CE and UKCA Marking.

SUITABLE PROTECTION AGAINST:

Ammonia ● ● ● ○ ○ ●

Arsine ● ● ● ● ● ●

Asbestos ● ● ● ● ● ● ● ● ●

Bacteria ● ● ● ● ● ● ● ● ●

Benzene ● ● ● ● ● ●

Blister agent ● ● ● ● ● ●

Blood agent ● ● ● ● ● ●

Bromine ● ● ● ● ● ●

Carbon Dioxide

Carbon Disulphide ● ● ● ● ● ●

Carbon Monoxide

Carbon Tetrachloride ● ● ● ● ● ●

Chlorine ● ● ● ● ● ●

Chlorine Dioxide ● ● ● ● ● ●

Chloroacetophenone
● ● ● ● ● ● ● ●
(CN)

Chloropicrin ● ● ● ● ● ●

o-Chlorobenzylidene
● ● ● ● ● ● ● ●
Malononitrile (CS)

Cyanogen ● ● ● ● ● ●

Cyanogen Chloride (CK) ● ● ● ● ● ●

Cyclohexane ● ● ● ● ● ●

Fluorine ● ● ● ● ● ●

Fentanyl ● ● ● ● ● ● ● ● ●

avon-protection.com
FILTER SELECTION MATRIX

FILTER CFP100 CTCF50 CBRNCF50 CBRNCF50CE MILCF50 GPCF50 FM61 FM61EU CSCF50

SUITABLE PROTECTION AGAINST:

Formaldehyde ● ● ● ● ● ●

Hydrogen Chloride ● ● ● ● ● ●

Hydrogen Cyanide (AC) ● ● ● ● ● ●

Hydrogen Fluoride ● ● ● ● ● ●

Hydrogen Sulfide ● ● ● ● ● ●

Lewisite ● ● ● ● ● ●

Methylamine ● ● ● ○ ○ ●

Methyl Bromide ● ● ● ● ● ●

Methyl Iodide ● ● ● ● ● ●

Mustard (HD) ● ● ● ● ● ●

Nerve agent ● ● ● ● ● ●

Nitrogen Dioxide ● ● ● ● ● ●

Nuisance dusts ● ● ● ● ● ● ● ● ●

Nuisance odours ● ● ● ● ● ● ● ●

Oleoresin Capsicum
● ● ● ● ● ● ● ●
(OC, pepper gas)

Organic vapours
● ● ● ● ● ●
w/ boiling point >65°C

Particulates ● ● ● ● ● ● ● ● ●

Phosgene ● ● ● ● ● ●

Phosphine ● ● ● ● ● ●

Radioactive particulates ● ● ● ● ● ● ● ● ●

Sarin (GB) ● ● ● ● ● ●

Soman (GD) ● ● ● ● ● ●

Sulphur Dioxide ● ● ● ● ● ●

Tabun (GA) ● ● ● ● ● ●

Toluene ● ● ● ● ● ●

Virus ● ● ● ● ● ● ● ● ●

VX ● ● ● ● ● ●

Xylene ● ● ● ● ● ●

LEGEND WARNINGS

Filter Body Style These filter recommendations are for guidance only. It is assumed that
some filters are used only once and then replaced.
Respirator filters must be selected by a competent person following
Conformal Convertible a suitable and sufficient risk assessment.
TCP Filters must be used in accordance with appropriate guidelines, regulations or
doctrine applied in line with the legislation of the country of application,
● Filter Effective inappropriate use could result in injury or death.
Filters must be stored in accordance with Avon’s user instructions.
○ Limited Effectiveness
The incident commander must establish a filter change schedule based on a
suitable and sufficient risk assessment. Failure to do so may result in filter
Contact Avon Protection
breakthrough and consequent injury or death. Contact Avon for assistance.
for additional information
Do not use filtering respirators in oxygen deficient atmospheres (<19.5%) or in
poorly ventilated spaces.
Avon conformal filters for use on specific Avon masks only. Filters may not
40mm Stanag Thread 40mm Stanag Thread
seal with other products leading to serious injury or death.