Asm VR123
Asm VR123
153.00018210 I 2008-07
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I Table of Contents
Table of Contents
Page 2
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I Table of Contents
7 Repair 51
7.1 Components overview 52
7.2 Top cover 57
7.3 Casing ventilation 59
7.4 Retarder ventilation 63
7.5 Non-return valve 65
7.6 Oil cooler 67
© 2008
Page 3
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I Table of Contents
Page 4
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I About this document
Page 5
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I About this document Purpose of this document
Operating Instructions for Diana-Lite test software Information on the testing of: Included in the scope of delivery
• Constant-air pressure control loop of the Diana-Lite test software
(153.000776xx)
• Dynamic pressure (pdyn)
Operating Instructions for the "WinDia®" diagnostic Instructions on PC diagnosis for the Digiprop and VERATM control-units 3623-020900
software
© 2008
Page 6
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I About this document Other applicable documents
Page 7
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I About this document Symbols and identifications
Page 8
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I Basic safety information
Page 9
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I Basic safety information Product safety
2.1 Product safety 2.4 Environmental protection Danger of accidents if the retarder tester is used
improperly!
The retarder is constructed according to the state of Ö Drained fuels and fluids, consumables and old parts
Diagnosis while the vehicle is traveling results in an
the art in technology and acknowledged safety must be disposed of properly. uncontrollable operating state of the vehicle.
regulations.
2.5 Special tools Ö Carry out diagnosis only while the vehicle is
Nevertheless, hazardous situations and property standing still.
damage may occur as a result of improper usage,
Damage to property if false special tools are used!
maintenance and repair.
The special tools required are described in the 2.7 Maintenance and repair
Ö Observe safety and warning information. respective action instructions.
The chapter "Overview of the tools" contains an Danger of burning and scalding via squirting oil!
2.2 Staff qualification overview of the special tools. The oil in the retarder may be hot.
In the case of special tools that may only be used from Ö Switch off the retarder and ignition so that oil is not
Ö Allow only qualified professionals to carry out repair
a specific version on, the version number is contained fed via pulse lubrication.
and maintenance work.
in the last two digits of the Voith item no. Example:
H53.942811. Ö Work carefully.
2.3 Safety-conscious working
Ö Only use special tools from the specified version Danger of burning and scalding via hot coolant!
Voith does not assume any liability for personal injury on. The coolant may be hot.
and/or property damage caused by improper and Ö Take the last two digits of the Voith item no. into
unprofessional work. Ö Work carefully.
account in the graphics of the special tools.
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 10
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I Basic safety information Driving mode
Danger of burns via hot parts! 2.8 Driving mode Failure or performance reduction while driving
Parts of the retarder may be hot. During failure of the retarder, or while temperature
Ö Ensure that the retarder is fully functional for all adaptation is active:
Ö Work carefully. vehicle maneuvers, i.e.:
Ö Adjust the speed of the vehicle with the engine/
Ö Wear protective gloves or use cloths if necessary. - retarder properly filled with oil
service brake.
- retarder electronic equipment connected and
Damage to property via soiled parts! functional Ö Engage the lowest possible gear in order to achieve
Considerable damage or malfunctions may occur due - pneumatic control connected and functional a high engine speed.
to soiling. - retarder connected to the vehicle's cooling
Ö During a temperature adaptation continue driving in
system
Ö Ensure cleanliness. this way until the retarder is available at full capacity
again.
Driving after oil change/checking the oil level
Damage to property via improper cleaning!
Ö When starting driving: Activate the retarder briefly in 2.9 Storage
Ö Do not aim the jet of a high-pressure cleaner
braking stage 2 or 3.
(steam-jet device) at valves, pressure sensors or Ö Store or transport the retarder vertically, otherwise
the ventilation of the retarder. oil may escape.
Towing
Ö Tow the vehicle with the retarder rotating for max. Ö Use transportation supports to center and secure
100 km at max. 40 km/h. the sleeve shaft.
Parking
Page 11
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 I Basic safety information Warranty
2.10 Warranty
Page 12
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function
Page 13
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function Overview of the modules
1500
© 2008
1900 2000
32002
Page 14
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function Overview of the modules
20100
Voith Turbo I 153.00018210 I arrtd I 2008-07
20200
1500
1700
© 2008
32003
Page 15
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function Retarder identification
NOTE
Ö Specify the following data in case you have
questions or are ordering spare parts:
- Serial number (FABR.Nr.)
- Voith item number (Voith Sach-Nr.)
TYP VR 123
FABR.Nr.
Baujahr
iRET = 1.00
TYP VR 123
FABR.Nr.
Kd.-Sach-Nr.
Baujahr
iRET = 1.00
Kd.-Sach-Nr.
Voith-Sach-Nr.
Voith Turbo I 153.00018210 I arrtd I 2008-07
Voith-Sach-Nr.
© 2008
32004
Page 16
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function VERA™ control-unit identification
NOTE
Ö Specify the following data in case you have
questions or are ordering spare parts (marked in
84
20
XX
02
gray):
e1
XX
XXX
X
T XX
-T -XX
- Serial number (Serial-No.) -
M
M .XX
t J
ni JJ XX XX
X X3
lU /J -X X
ro XX .X XX
- Item number (Part No.) t
n X .E X
Co XX RA XX
X
er . E X X2
rd No V X
ta ial- o. . X
Ö Specify the following data of the retarder (see e
R er rt N N
S a M
o
P E
X1
o
rb
Tu
O
Page 16):
th i
Vo
H
IT
VO
- Serial number (FABR.Nr.)
- Voith item number (Voith Sach-Nr.)
Example display
Voith Turbo I 153.00018210 I arrtd I 2008-07
Voith Turbo
e1 032084
OEM No. XXXXXXXXXXXXX
VOITH
X1 X2 X3
© 2008
32006
Page 17
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function Digiprop control-unit identification
NOTE
Ö Specify the following data in case you have
questions or are ordering spare parts:
- Code number (Code-Nr.)
- Voith item number (Voith)
Ö Specify the following data of the retarder (see
Page 16):
- Serial number (FABR.Nr.) Ba
s
Co is-N
d r.
Se e-N :
- Voith item number (Voith Sach-Nr.) r r
VO ien-N.: 53
ITH r.: .
xx xxxx
x .12
xx
xx
/
Example display
Voith Turbo I 153.00018210 I arrtd I 2008-07
Basis-Nr.:
Code-Nr.:
Serien-Nr.:
VOITH
© 2008
32084
Page 18
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function Function and control scheme
4000 Rotor
300 2400 H G
5000 Proportional valve
1500 1700
6000 Oil cooler
7000 Pressure sensor
8000 Oil temperature sensor Oil sump Coolant
20600 Coolant temperature sensor
Supply-air pressure pv Dynamic pressure pdyn
© 2008
Page 19
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function Function description
3.6 Function description Stator (300) Bore for casing ventilation in cover at top (3000)
In the stator (300) the oil is re-directed and is returned Connects the retarder circuit with the atmosphere.
Air and vent duct "A" constant-air pressure py (D) to the rotor (4000) at the internal diameter of the Aerates and deaerates the retarder circuit via the
Air and vent duct for constant-air pressure py between working chamber. casing ventilation (2300).
proportional valve (5000) and oil tank (F).
Non-return valve (1900) Retarder ventilation "R" (3300)
Ventilation duct "R" (E) The non-return valve (1900) prevents the oil cooler When the retarder is switched off, the compressed air
Ventilation duct for constant-air pressure py between (6000) from being emptied in no-load mode. in the oil tank (F) is emitted to the atmosphere via
proportional valve (5000) and retarder ventilation "R" retarder ventilation "R" (3300).
(3300). Casing ventilation (2300)
At the start of the braking process, the oil displaces the Rotor (4000)
Rising duct (G) air in the retarder in the system circuit. The air is The rotor (4000) must include the oil in its rotation and
Connection between oil tank (F), retarder circuit and oil displaced via the casing ventilation (2300) and the bore accelerate it.
cooler (6000). During braking, oil flows from the oil tank for casing ventilation in the cover at the top (3000).
(F) via the rising duct (G) and the inlet throttle (105) into Proportional valve (5000)
Once the system circuit is free of air, the casing
the retarder circuit. When switched off, the oil coming The proportional valve (5000) is connected to the
ventilation (2300) closes.
from the oil cooler (6000) flows via the rising duct (G) compressed-air system of the vehicle (auxiliary
back into the oil tank (F). equipment circuit). As soon as the proportional valve
Outlet throttle (braking mode) (2400)
(5000) receives an electrical input signal from the
Outlet throttle (no-load mode) (H) In braking mode, the oil reaches the oil cooler (6000)
retarder control-unit, it issues a pneumatic constant-air
through the outlet throttle (2400) from the working
In no-load mode, the oil reaches the oil cooler (6000) pressure py which depends on the intensity of the
chamber, cooled and fed back into the system circuit.
Voith Turbo I 153.00018210 I arrtd I 2008-07
through the outlet throttle (H) from the working electrical input signal and which acts on the oil tank (F)
chamber. of the retarder.
Return valve (2600)
Inlet throttle (105) The oil that was separated from the cut-of air via the Oil cooler (6000)
opened return valve (2600) is returned to the oil tank
When the retarder is switched on, the oil sump is The oil cooler (6000) dissipates the generated heat to
(F). If the oil sump is pressurized, the return valve
pressurized and the oil reaches the retarder circuit via the vehicle cooling system.
(2600) closes. This prevents oil from exiting via the
the inlet throttle (105).
© 2008
Page 20
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Design and function Function description
reduction to 0).
Page 21
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service
Page 22
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Maintenance intervals
CAUTION
Exceeding of the maintenance intervals/
incorrect oil sort!
Damage to/failure of the retarder.
Ö Observe the maintenance intervals.
Ö Use only approved oils.
Page 23
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Oil change
NOTE
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non-
corrosive grease before installation.
Voith Turbo I 153.00018210 I arrtd I 2008-07
1400
1500
1600 1600
1700
© 2008
1700
32008
Page 24
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Oil change
Draining the oil 5. Lubricate the new sealing rings (1400 and 1600)
Oil quantity
with silicone-free and non-corrosive grease.
Initial filling (new unit) 6.0 l 1. Place oil pan below the retarder.
6. Screw in the screw plugs (1500 and 1700) with
Initial filling (replacement unit) 6.8 l
WARNING sealing rings (1400 and 1600).
Service filling (checking of the oil 6.0 l
level, oil change) Hot exiting oil! 7. Tighten the screw plug (1500) to 25 Nm.
After replacing the oil cooler and 6.0 l Face and hands could be burned.
Ö Ensure that the retarder and ignition are switched 8. Tighten the screw plugs (1700) to 80 Nm.
rinsing the retarder
After replacement of the oil 6.5 l off.
cooler
Requirements
• Vehicle is horizontal
NOTE
Ö If the oil contains water: Check the oil cooler
• Oil at operating temperature (>60°C) (see Page 67).
• Retarder switched off
© 2008
Page 25
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Oil change
CAUTION
Wrong oil type!
Damage to/failure of the retarder.
Ö Fill in only approved oil (see Voith Retarder oil
change interval/Oil selection list).
NOTE
When starting driving:
Ö Activate the retarder briefly in braking stage 2 or
3.
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 26
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Checking the oil level
NOTE
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non-
corrosive grease before installation.
Voith Turbo I 153.00018210 I arrtd I 2008-07
1600 1600
© 2008
1700 1700
32008
Page 27
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Checking the oil level
Page 28
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Draining the coolant
NOTE
Depending on the vehicle manufacturer, the design
of the water neck can differ.
Ö If the screw plug (20200) does not exist: Drain
the coolant at the vehicle (see specifications of
vehicle manufacturer).
TYP R 123
NOTE
FABR.Nr.
Baujahr
iRET = 1.00
Kd.-Sach-Nr.
Voith-Sach-Nr.
20100
20300
20200
© 2008
32085
Page 29
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Draining the coolant
Requirements
CAUTION
• Retarder switched off
Wrong coolant type!
• Ignition switched off Damage to the vehicle and retarder cooling circuit.
Ö Observe the specifications of the vehicle
Draining the coolant
manufacturer or those of Voith Turbo coolant
1. Place a clean coolant collecting pan under the quality list.
retarder.
5. Fill the vehicle and retarder cooling circuit (see
CAUTION specifications of vehicle manufacturer).
Page 30
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Maintenance and service Proportional valve
NOTE
Ö For vehicles used mainly in city traffic: Replace
the proportional valve every 120,000 km (see
Page 81).
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 31
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting
Page 32
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Overview of the possible complaints
Page 33
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Overview of the possible complaints
NOTE
On-board diagnosis is possible at some vehicle
manufacturers (display).
Ö Observe the specifications of the vehicle
manufacturer.
Page 34
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Overview of the possible complaints
A1 Retarder pilot light does not go out after the lamp test
Page 35
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Overview of the possible complaints
Page 36
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Overview of the possible complaints
9. ÖCheck oil temperature sensor and supply line (see NOK 10.
Page 76etc.).
ÖCheck coolant temperature sensor and supply line OK 11.
(see Page 78etc.).
Page 37
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Overview of the possible complaints
Page 38
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Overview of the possible complaints
C Oil leak at the retarder ventilation (3300) or bore for casing ventilation in the cover at the top (3000)
Page 39
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the constant-air pressure control loop
NOTE 2800
99/7
2900
The constant-air pressure control loop check
provides information about
• internal and external leaks of the retarder
• proper functioning of the retarder
• proper control of the retarder
7000
Item No. Name
2800 Screw plug M 30 x 1.5; 6
50/56b
hexagon socket head, w.a.f. 17; 5000
130 Nm
2900 Sealing ring A 30 x 36; replace
5000 Proportional valve
7000 Pressure sensor
50/56a Retarder tester 50/56c
Voith Turbo I 153.00018210 I arrtd I 2008-07
32091
Page 40
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the constant-air pressure control loop
CAUTION
Commercially available tools
Hot parts!
Multimeter Hands could be burned.
Ö Work carefully.
Requirements
Ö Wear protective gloves or use cloths if necessary.
153.001085xx H53.1403xx 153.000776xx
• Ignition switched off
Connecting the pressure gauge
Retarder tester, Pressure gauge Test software • Retarder switched off
complete in a 0–6 bar "DIANA Lite" 1. Unscrew the screw plug (2800) with the sealing
case • Battery voltage: 18–32 V ring (2900).
50/56 99/7 50/56i • Supply-air pressure in auxiliary circuit 6–11 bar 2. Connect the pressure gauge (99/7) to the bore of
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 41
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the constant-air pressure control loop
Connecting the retarder tester Checking the supply voltage of the pressure Checking the proportional valve
sensor
15.Switch the toggle switch to the position "EIN ohne
VR 123
5000
6. Switch on the vehicle ignition Regelkreis" (on without control loop).
50/56b 10
833
1 153.000
2 50/56c 7. Set the "RETARDERTYP" (retarder type) switch at 16.Start the "DIANA-Lite" test software.
50/56a 153.00
08341 the retarder tester (50/56a) to "5".
3 50 0 7000
15
3.0
/56 17.Load the template for the retarder tester (see
4
00
d
83
51 8000 8. Switch the toggle switch to the position "EIN mit Operating Instructions of "DIANA-Lite" test
0
Regelkreis" (on with control loop). software).
20600
50/56e 9. Connect the multimeter to the "U_Versorgung" 18.Set the "STELLDRUCK" (constant-air pressure)
153.00083610
(U_Supply) socket (measuring type: V). switch at the retarder tester to "25%".
32105
10.Read the measured value: Nominal value 4.75– NOTE
5.25 V.
1. Connect cable 1 (50/56b) to the proportional valve
To assess the operation of the proportional valve
(5000). 11.If the value deviates: Replace the pressure sensor (5000), the results of the following test are only
(7000) (see Page 80). valid during a testing period of 60 seconds
2. Connect cable 2 (50/56c) to pressure sensor
maximum.
(7000).
Checking the signal value of the pressure sensor
3. Connect cable 3 (50/56d) to the oil (8000) and 19.In "DIANA-Lite" read the "Stelldruck Ist" (constant-
12.Connect the multimeter to the "U_py IST" (U_py
coolant (20600) temperature sensors. air pressure actual) measured value and the
actual) socket (measuring type: V). measured value at the pressure gauge (99/7):
Voith Turbo I 153.00018210 I arrtd I 2008-07
4. Connect cable 4 (50/56e) to the vehicle voltage Nominal value after approx. 20 seconds:
supply/PC interface. 13.Read the measured value: Nominal value 0.275–
0.725 V.
5. Connect all the cables to the retarder tester (50/
56a) (see also the Operating Instructions of the 14.If the value deviates: Replace the pressure sensor
retarder tester). (9000) (see Page 105).
© 2008
Page 42
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the constant-air pressure control loop
75% 1,80–2,30
100% 2,60–3,10
Page 43
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the dynamic pressure (pdyn)
NOTE
Checking the dynamic pressure pdyn provides
information about
• the mechanical status of the rotor parts
• internal leaks
• proper functioning of the retarder 7000
Page 44
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the dynamic pressure (pdyn)
• Vehicle secured
NOTE NOTE
• Prop shaft at retarder removed from flanges and
Ö Lubricate sealing rings, O-rings and shaft In addition to the tests with the retarder tester, secured (see specifications of vehicle
sealing rings with silicone-free and non- measured values can also be read out and stored manufacturer)
corrosive grease before installation. using the testing software "Diana Lite" (50/56i) on
the PC.
The stored measured values can be transmitted to
DANGER
Special tools Voith customer service for evaluation (see Danger of accidents if the retarder tester is used
Operating Instructions on CD-ROM). improperly!
Uncontrollable operating state of the vehicle.
Requirements Ö Carry out diagnosis only while the vehicle is
standing still.
• Ignition switched off
Page 45
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the dynamic pressure (pdyn)
15
4 3.0 d
00
83 8000
51
0
11.Start the "DIANA-Lite" test software.
1400 20600
1500 50/56e 12.Load the template for the retarder tester (see
153.00083610
32078 Operating Instructions of "DIANA-Lite" test
32106
software).
1. Unscrew screw plug (1500) and remove sealing
© 2008
ring (1400).
Page 46
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the dynamic pressure (pdyn)
14.Adjust the engine speed to 1500 min-1 Disconnecting the pressure sensor and retarder
tester
15.Set the "STELLDRUCK" (constant-air pressure)
switch at the retarder tester to "25%". 19.Set the "STELLDRUCK" (constant-air pressure)
switch at the retarder tester to "0%".
16.Adjust the engine speed to 1500 min-1 once
again. 20.Disconnect the retarder tester (50/56a) and all
cables.
17.Set the "STELLDRUCK" (constant-air pressure)
switch at the retarder tester to "50%". 21.Disconnect the pressure sensor (50/56g).
18.With a engine speed of 1500 min-1, read the 22.Lubricate the new sealing ring (1400) with
"Gehäusedruck Ist" (housing pressure actual) silicone-free and non-corrosive grease.
measurement value in "DIANA Lite":
23.Screw in the screw plug (1500) with the sealing
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 47
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the proportional valve current
Requirements
Page 48
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Diagnosis and troubleshooting Checking the proportional valve current
NOTE
Due to continuous readjustment in the control loop,
the measured values may not be constant, but are
within the specified range.
Page 49
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Removing and installing the retarder
DANGER CAUTION
Retarder can fall! Hot parts!
Your body can be crushed severely. Hands could be burned.
Ö Secure retarder against falling. Ö Work carefully.
Ö Use a suitable lifting device. Ö Wear protective gloves or use cloths if necessary.
CAUTION CAUTION
Improper removal/installation! Unsecured sleeve shaft!
Damage to/failure of the retarder. Damage to radial shaft sealing rings.
Warranty is voided. Ö Use transportation supports to center the sleeve
Ö Request and use gearbox-specific documents shaft.
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 50
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair
7. Repair
Page 51
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Components overview
20400
NOTE 1000
4800
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non- 20300 6100
20500 1400 6150
corrosive grease before installation. 1950 6150
20200 4702 6300
1400 1500 1900
4703 4800
1500 1600
1700
© 2008
32012
Page 52
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Components overview
20400
1000
4800
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non- 6100
20300 20500 1400
corrosive grease before installation. 6150
20200 4702 1950 6150
1400 1500 1900 6300
4703 4800
1500 1600
1700
© 2008
32012
Page 53
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Components overview
20300 6100
20500 1400 6150
20200 4702 1950 6150
1400 1500 1900 6300
4703 4800
1500 1600
1700
© 2008
32012
Page 54
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Components overview
20400
1000
4800
20300 6100
20500 1400 6150
20200 4702 1950 6150
1400 1500 1900 6300
4703 4800
1500 1600
1700
© 2008
32012
Page 55
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Components overview
Replace component
Item No. Name
20000 Water neck inlet (optional) Check component
according to specifications
20100 Water neck outlet (optional)
and replace if necessary
20200 Screw plug M 14 x 1.5;
hexagon socket head, w.a.f. 6; 25 Nm Perform visual inspection
2800
and replace if necessary
20300 Sealing ring A 14 x 18 2900
5300
20400 Hex.-head screw M 8 x 45; 3600 5100
5200
hexagon insert bit, w.a.f. 13; 30 Nm 5200 5000
20500 O-ring 55.56 x 3.53 3000 5400
20600 Coolant temperature sensor
M 14 x 1.5; 3500
hexagon insert bit, w.a.f. 27; 28 Nm 3200
3400
2600
20700 Sealing ring A 14 x 20 3300 2700
2300 7000
20000 100 8100
20500 2301
NOTE 20400
8000
6100
6000
6150 2000 3600
Ö Lubricate sealing rings, O-rings and shaft 6150
6200
sealing rings with silicone-free and non- 20600
20100 20700
corrosive grease before installation.
2100
Voith Turbo I 153.00018210 I arrtd I 2008-07
20400
1000
4800
20300 6100
20500 1400 6150
20200 4702 1950 6150
1400 1500 1900 6300
4703 4800
1500 1600
1700
© 2008
32012
Page 56
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Top cover
Requirements
32013
Page 57
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Top cover
CAUTION A
5
Hot parts! 3 6
1 4
Hands could be burned. 2
Ö Work carefully. 8
7
Ö Wear protective gloves or use cloths if necessary. 10 9
12 11
Removing 3000
13
1. Unscrew the hex.-head screws (3600).
32113 32014
2. Remove the cover (3000).
3. Remove the gasket (3200). 2. Fill compressed air into the open side of the duct 3. Tighten the hex.-head screws (3600) in the
(A) and check the bore in the cover (3000) for air prescribed sequence (see diagram) to 17 Nm.
Checking flow (see arrow).
4. Tighten the hex.-head screws (3600) in the
prescribed sequence (see diagram) to 30 Nm.
Installing
CAUTION
Incorrect sequence when tightening the hex.-
A head screws!
32111
Cover can buckle.
1. Seal the duct (A) airtight on one side. Ö Tighten the hex.-head screws in the prescribed
sequence.
© 2008
Page 58
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Casing ventilation
NOTE
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non-
corrosive grease before installation.
Aids
Voith Turbo I 153.00018210 I arrtd I 2008-07
32015
Page 59
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Casing ventilation
7 mm
account in the graphics of the special tools. Ø 60 mm
Removing
H67.2757xx
Special tools 99/5
Test ring
99/4
Material: St 37 98/9
Weight: 0.085 kg 2300/1
Page 60
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Casing ventilation
Checking
.
2300/2
1. Check the casing ventilation (2300) for soiling and
99/4
sludge and clean it.
2300/3
2300/2
2300/1
2300/2
32018 32021
3. If necessary, remove the float (2300/2) and the 5. Check the sealing edge of the radial shaft sealing
float cage (2300/3) from the retarder housing. ring (arrow) in the valve insert (2300/1):
32020
- place the float (2300/2) on a suitable object
(e.g. hex.-head nut)
2. Check the float (2300/2) for damaged surfaces
and sealing areas (arrow). - place the valve insert (2300/1) on the float and
2300/1 weigh it down using the test ring (99/4)
3. Weigh the float (2300/2): Specified weight:
- fill the empty space between the float (2300/2)
max. 12 g.
and upper edge of the valve insert with ethyl
4. For exceeded specified weight: Replace the entire alcohol
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 61
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Casing ventilation
98/9
2300/3 2300/1
32023
2300/1
2. Clean the float with ethyl alcohol.
32024
NOTE
8. Carefully press the casing ventilation (2300) into
For casing ventilation from Voith item no.
2301 the retarder housing with the impact puller (99/5)
H53.133214 upwards:
and adapter (98/9).
Ö Observe the installation position of the float: The
32022
side marked "O" faces upwards. 9. Complete the retarder.
1. Lubricate the new O-ring (2301) with silicone-free
3. Place the float (2300/2) onto the float cage (2300/3).
and non-corrosive grease and pull it on the valve
Voith Turbo I 153.00018210 I arrtd I 2008-07
insert (2300/1). 4. Place the valve insert (2300/1) onto the float cage
(2300/3).
Page 62
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Retarder ventilation
3500 Circlip
3500
Aids
Benzene for disc silencer
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
32025
Page 63
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Retarder ventilation
Requirements
DANGER
Heavily soiled or painted-over retarder
ventilation!
Retarder reduces braking power after a delay.
Ö Replace retarder ventilation.
CAUTION
Mechanically damaged retarder ventilation!
Malfunction of the retarder.
Ö Replace retarder ventilation.
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 64
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Non-return valve
NOTE
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non-
corrosive grease before installation.
1900/3
1900/2
1900/1
Voith Turbo I 153.00018210 I arrtd I 2008-07
1950
1900
© 2008
32027
Page 65
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Non-return valve
Requirements Checking
CAUTION
1900/3
Hot parts!
Hands could be burned.
Ö Work carefully.
Ö Wear protective gloves or use cloths if necessary. 1900/2
32108
Removing
1. Check the rubber coating of the piston (1900/3) for
1. Unscrew the guide (1900/1). damage. If necessary, replace the entire non-
2. Remove the spring (1900/2) and piston (1900/3) return valve (1900).
from the retarder housing. 2. Check the guide (1900/1) and spring (1900/2) for
wear. If necessary, replace the entire non-return
valve (1900).
Voith Turbo I 153.00018210 I arrtd I 2008-07
Installing
Page 66
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Oil cooler
NOTE
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non-
corrosive grease before installation.
© 2008
32028
Page 67
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Oil cooler
Checking
Special tools
CAUTION
Hot parts!
Hands could be burned. 50/65
Ö Work carefully.
Ö Wear protective gloves or use cloths if necessary.
Removing
153.000769xx 6000
1. Unscrew the hex.-head screws (3600, 4800, 6200
and 6300).
Pressure test
32094
equipment 2. Remove the cover (2000) using suitable lifting
equipment.
50/65 1. Attach the pressure test device (50/65) with
3. Remove the O-rings (1000 and 2100) O-rings to the oil cooler (6000) and connect the
Requirements compressed-air line.
4. Remove the oil cooler (6000).
• Retarder switched off 2. Place the oil cooler (6000) with the pressure test
device (50/65) in a water bath (approx. 60°C).
• Ignition switched off
3. Slowly pressurize the oil cooler (6000) with
• Supply-air pressure drained
compressed air from 0–max. 10 bar.
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 68
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Oil cooler
4. If air bubbles form in the water: Replace the oil 3. Insert the oil cooler (6000).
cooler (6000). 4. Lubricate the new O-ring (2100) with silicone-free
1000 6100
6150 and non-corrosive grease and pull it on.
5. Release the compressed air and detach the 32095
compressed-air line.
3 7
6. Remove the oil cooler (6000) from the pressure
CAUTION 3600
4800 4800
test device (50/65). 3600
Leaks (internal/external)! 2000
6200 1 6
Installing Malfunction of the retarder.
4800
Ö Use only O-rings 25 x 2.5, Voith item no. 6300
NOTE 190.00230210.
4800 4800
The water and oil section of new oil coolers are
coated with anti-corrosion oil.
1. Lubricate the new O-rings (6100) and (6150) with 2
silicone-free and non-corrosive grease and pull 5 4
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 69
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Oil cooler
CAUTION CAUTION
Incorrect sequence when tightening the hex.- In case of water in the retarder!
head screws! Oil emission through retarder ventilation.
Cover can buckle. Malfunction of the retarder
Ö Tighten the hex.-head screws in the prescribed Ö Fill the retarder with 6.0 l of oil (as per the Voith
sequence (see diagram). Retarder oil change intervals/Oil selection list).
Ö Flush the retarder system by braking several
6. Tighten the hex.-head screws (3600, 4800) in the times lightly.
prescribed sequence (see diagram) to 17 Nm. Ö Drain the oil.
Ö Repeat the process 2 or 3 times.
7. Tighten the hex.-head screws (3600, 4800) in the
Ö De-oil the cooling and heating system (see
prescribed sequence (see diagram) to 30 Nm.
specifications of vehicle manufacturer).
8. Screw in the hex.-head screws (6200 and 6300)
and tighten to 46 Nm. 11.Fill in the oil (see "Oil change" on Page 24).
CAUTION
Wrong coolant type!
Damage to the vehicle and retarder cooling circuit.
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 70
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Water neck
NOTE
Depending on the vehicle manufacturer, the design
of the water neck can differ (see specifications of
vehicle manufacturer).
20500
20700 Sealing ring A 14 x 20; replace
20500
20700
NOTE 20400
20300 20400
32029
Page 71
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Water neck
Requirements
CAUTION
Hot parts!
Hands could be burned.
Ö Work carefully.
Ö Wear protective gloves or use cloths if necessary.
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 72
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Return valve
Special tools
H53.6820xx H53.1403xx
50/66 99/7
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
32101
Page 73
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Return valve
Requirements Checking
5100 50/66
3
• Retarder switched off 2600
A
• Ignition switched off 2700 4
100
• Proportional valve and damping plate removed A
(see Page 81)
CAUTION 2
99/7 32110
Hot parts!
32109
Hands could be burned. 3. Attach the top cover (3000) (see Page 57).
Ö Work carefully.
4. Attach the damping plate (5100) with new O-rings
Ö Wear protective gloves or use cloths if necessary.
CAUTION (5200) (see Page 81).
Retarder housing open!
5. Attach the adapter plate (50/66) with hex.-head
The test specimen (A) can fall into the retarder
nuts M 8, tightening torque 18 Nm, to the damping
housing.
plate (5100).
Ö Hold the test specimen (A) securely.
6. Connect the pressure gauge (99/7) and pressure
1. Check whether the washer (2700) is located under reducer (3) to the compressed-air line (4).
Voith Turbo I 153.00018210 I arrtd I 2008-07
Page 74
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Return valve
Page 75
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Oil temperature sensor
NOTE
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non-
corrosive grease before installation. 8100
Requirements
Voith-Sach-Nr.
CAUTION 8000
Voith Turbo I 153.00018210 I arrtd I 2008-07
Hot parts!
Hands could be burned.
Ö Work carefully.
Ö Wear protective gloves or use cloths if necessary.
© 2008
32032
Page 76
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Oil temperature sensor
NOTE
Measuring in one temperature range is usually
sufficient.
Polarity irrelevant.
Temperature Resistance
20°C ± 10°C 1039–1117 Ω
60°C ± 10°C 1194–1271 Ω
80°C ± 10°C 1271–1347 Ω
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 77
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Coolant temperature sensor
NOTE
Ö Lubricate sealing rings, O-rings and shaft
sealing rings with silicone-free and non-
corrosive grease before installation.
Requirements
Voith-Sach-Nr.
CAUTION
Hot parts! 20600
Hands could be burned.
Ö Work carefully.
Ö Wear protective gloves or use cloths if necessary.
© 2008
32033
Page 78
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Coolant temperature sensor
NOTE
Ö Regarding the coolant quality, observe the
specifications of the vehicle manufacturer or
those of the Voith Turbo coolant quality list.
NOTE
Measuring in one temperature range is usually
sufficient.
Polarity irrelevant.
Temperature Resistance
20°C ± 10°C 1039–1117 Ω
60°C ± 10°C 1194–1271 Ω
80°C ± 10°C 1271–1347 Ω
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 79
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Pressure sensor
NOTE
Ö Lubricate the FPM sealing ring on both sides
with silicone-free and non-corrosive grease
before installation.
Requirements
CAUTION
Voith Turbo I 153.00018210 I arrtd I 2008-07
Hot parts!
Hands could be burned.
Ö Work carefully.
Ö Wear protective gloves or use cloths if necessary.
32031
Page 80
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Proportional valve and damping plate
NOTE
Voith Turbo I 153.00018210 I arrtd I 2008-07
32030
Page 81
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Repair Proportional valve and damping plate
Requirements
CAUTION
• Retarder switched off
Incorrect sequence when tightening the hex.-
• Ignition switched off head nuts!
• Supply-air pressure drained Proportional valve can be damaged.
Ö Tighten the hex.-head nuts in the prescribed
• Compressed-air line disconnected sequence to 18 Nm.
NOTE 1
2
Ö Check damping plate (5100) for mechanical and
aging damage and replace if necessary. 3
32112
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 82
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Overview of the tools
8.1 Diagnosis 84
8.2 Repair 86
CAUTION
False special tools!
Damage to components.
Ö Only use special tools from the specified version
onward.
Ö Take the last two digits of the Voith item no. into
account in the graphics of the special tools.
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 83
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Overview of the tools Diagnosis
8.1 Diagnosis
153.001085xx 153.000776xx
50/56 50/56i
Page 84
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Overview of the tools Diagnosis
H53.8198xx
Measuring
adapter
99/3
Voith Turbo I 153.00018210 I arrtd I 2008-07
© 2008
Page 85
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Overview of the tools Repair
8.2 Repair
Ø 40.5 mm
7 mm
Ø 60 mm
153.000769xx
Voith Turbo I 153.00018210 I arrtd I 2008-07
Pressure test
equipment
50/65
© 2008
Page 86
Voith Turbo I Aftersales Service Manual Voith Retarder VR 123 - 153.00018210 I Overview of the tools Repair
H53.6820xx H53.1403xx
Page 87
Voith Turbo
Produktgruppe Retarder
Postfach 1555
D-74555 Crailsheim, Germany
Tel. +49 79 51 32-0
Fax +49 79 51 32-756
[email protected]
www.voith.com
Engineered reliability.