ECU - Veera - Fault Code List
ECU - Veera - Fault Code List
Reading out the fault memory via the retarder stage switch
While the service mode is active i.e. after the ignition was turned ON, v = 0, the flashing code can
be started via the retarder stage switch:
There is a break of 3 seconds before and after each flashing code during which the retarder pilot
light is OFF.
The number of ones is then indicated as short ON intervals: 0.5 seconds each.
0.5 sec
0.5 sec
0.5 sec
0.5 sec
0.5 sec
1 sec
1 sec
1 sec
1 sec
1 sec
1 sec
2 sec
2 sec
If a relevant fault is indicated (the retarder pilot light is ON before triggering the flashing code), the
retarder pilot light will switch back to permanent light after the flashing code. 3 sec 3 sec
33048_en
Clearing the fault memory
Display example: Fault code 25
The fault memory can only be cleared via WinDia.
ON = Retarder pilot light ON
OFF = Retarder pilot light OFF
t = time
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 43
Diagnosis / Troubleshooting – Troubleshooting
Version VERA
Note
Flash (Test
Code Step)
5 1 Proportional valve serious 1s - Ignition: OFF X 3/3 Ω X 3/4 18 ... 25 Ω Check lead and
short circuit to - X3 plug proportional valve.
ground,discontinuity, disconnect
short circuit,
connecting cable
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 44
Diagnosis / Troubleshooting – Troubleshooting
9 1 Terminal 15 serious 60 s - Ignition: OFF X 1/7 V X 1/14 ≥ 17.5 V Check lead, plugs
Undervoltage - Plug X1 and fuse.
disconnect
- Ignition: ON
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 45
Diagnosis / Troubleshooting – Troubleshooting
11 1 Undefined state serious 2s - Ignition: ON X 1/10 V X 1/14 ≥ 17.5 V Check lead, plugs
of retarder stage - Retarder stage X 1/5 V X 1/14 0V and retarder stage
switch switch: X 1/6 V X 1/14 0V switch.
Position 0 X 1/8 V X 1/14 0V
X 1/9 V X 1/14 0V
X 1/18 V X 1/14 0V
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 46
Diagnosis / Troubleshooting – Troubleshooting
12 1 Retarder stage serious approx. 1 s - Ignition: OFF X 1/7V V X 1/5 <2 V Check lead, plugs
switch short to - Plug X1 V X 1/6 and retarder stage
ground disconnect V X 1/8 switch.
- Ignition: ON V X 1/9
V X 1/10
V X 1/18
13 1 Retarder stage serious 10 s - Ignition: OFF X 1/14V V X 1/5 <2 V Check lead, plugs
switch short to - Plug X1 V X 1/6 and retarder stage
high source disconnect V X 1/8 switch.
- Ignition: ON V X 1/9
V X 1/10
V X 1/18
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 47
Diagnosis / Troubleshooting – Troubleshooting
17 1 Cooling water slight 1s - Ignition: OFF X 3/1 Ω X 3/2 20 °C ± 10 °C = Check lead, plugs
temperature - X3 plug 1039–1117 Ω and sensor.
sensor disconnect
60 °C ± 10 °C =
discontinuity
1194 –1271 Ω
80 °C ± 10 °C =
1271–1347 Ω
Note:
Measuring in one
temperature
range is usually
sufficient.
18 1 Cooling water slight 1s - Ignition: OFF X 3/2 Ω X 1/14 Resistance Check lead.
temperature - Plug X1, X3 infinite
sensor disconnect
short circuit to
ground
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 48
Diagnosis / Troubleshooting – Troubleshooting
19 1 Oil temperature slight 1s - Ignition: OFF X 3/5 Ω X 3/6 20 °C ± 10 °C = Check lead, plugs
sensor - X3 plug 1039 –1117 Ω and sensor.
discontinuity disconnect
60 °C ± 10 °C =
1194–1271 Ω
80 °C ± 10 °C =
1271–1347 Ω
Note:
Measuring in
one temperature
range is usually
sufficient.
20 1 Oil temperature slight 1s - Ignition: OFF X 3/5 Ω X 1/14 Resistance Check lead and
sensor - Plug X1, X3 infinite plugs.
short circuit to disconnect
ground
23 1 Retarder pilot serious 1s - Ignition: OFF X 1/15 V X 1/14 ≥ 17.5 V Check lead and fuse.
light - Plug X1
discontinuity, disconnect
short circuit to - Ignition: ON
ground
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 49
Diagnosis / Troubleshooting – Troubleshooting
24 1 Retarder pilot serious 3s - Ignition: ON X 1/15 V X 1/14 ≤2V Check lead and
light - Retarder stage retarder pilot light.
discontinuity, switch:
short-circuit to Position 1
battery
25 1 Pressure sensor slight 0.5 s - Ignition: ON X 3/8 V X 3/9 4.75–5.25 V Check lead.
fault (supply)
26 1 Pressure sensor slight 1s - Ignition: OFF X 3/7 Ω X 1/14 Resistance Check lead and
discontinuity, - Plug X1, X3 infinite pressure sensor.
short circuit to disconnect
ground
27 1 Pressure sensor slight 1s - Ignition: ON X 3/7 V X 3/8 0.3–0.7 V Check lead and
short-circuit to - Retarder stage pressure sensor.
battery switch:
Position 0
28 1 Pressure sensor slight 10 s - Ignition: ON X 3/7 V X 3/8 0.3–0.7 V Check lead and
implausible - Retarder stage pressure sensor.
signal switch:
Position 0
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 50
Diagnosis / Troubleshooting – Troubleshooting
33 1 Stop light relay slight 1s - Ignition: OFF X 1/16 Ω X 1/14 With relay Check lead, plugs
short circuit to - Plug X1 installed: and relays or
ground disconnect 250–350 Ω consumers.
34 1 Stop light relay slight 1s - Ignition: ON X 1/16 V X 1/14 ≤2V Check lead, plugs
interruption or - Retarder stage and relays.
short to battery switch:
Position 0
Aftersales Service Manual Voith Retarder VR120-4 TML Diagnosis / Troubleshooting – Troubleshooting
153.00232910 / arrtd 2006-08 Seite 51