Fichas Tecnicas Figuras 980, 1000 y 4L
Fichas Tecnicas Figuras 980, 1000 y 4L
Cooper B-Line, Inc.’s (“Cooper B-Line”) seismic bracing components are designed to be compatible only with other Cooper B-Line bracing components,
resulting in a listed seismic bracing assembly. Cooper B-Line’s warranty for seismic bracing components will be the warranty provided in Cooper B-Line’s
standard terms and conditions of sale made available by Cooper B-Line, except that, in addition to the other exclusions from Cooper B-Line’s warranty, Cooper
B-Line makes no warranty relating to Cooper B-Line’s seismic bracing components that are combined with products not provided by Cooper B-Line.
COOPER B-LINE 1375 Sampson Ave • Corona, CA 92879 • 800.786.5266 • FAX: 951.737.0330
www.tolco.com
TOLCO™ Seismic Bracing
Fig. 4L - Longitudinal “In-Line” Sway Brace Attachment
Size Range: 2" (50mm) through 8" (200mm) IPS.
Material: Steel
Set Screw & Hardware
Function: For bracing pipe against sway and seismic disturbance. Included
Seismic Bracing
OSHPD guidelines should be followed.
To Install: Place the Fig. 4L over the pipe to be braced and tighten
bolts. Then engage "bracing pipe" into jaw opening and tighten set screw C
until head snaps off. Jaw attachment can pivot for adjustment to proper
brace angle.
Finish: Plain. Contact B-Line for alternative finishes and materials.
Order By: Figure number, pipe size and finish.
Longitudinal
Brace
4-Way Riser Brace
(plan view)
Eaton’s B-Line Business seismic bracing components are designed to be compatible only with other B-Line bracing components,
resulting in a listed seismic bracing assembly. B-Line’s warranty for seismic bracing components will be the warranty provided in
B-Line’s standard terms and conditions of sale made available by B-Line, except that, in addition to the other exclusions from
B-Line’s warranty, Eaton’s B-line Business makes no warranty relating to B-Line’s seismic bracing components that are combined
with products not provided by Eaton’s B-Line Business.
All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified.
Component of State of
Fig. 1000 - “Fast Clamp” Sway Brace Attachment California OSHPD Approved
Seismic Restraints System
Size Range — Pipe size to be braced: 1" thru 6" Schedule
10 thru 40 IPS.* Pipe size used for bracing: 1" and 11⁄4" Schedule 40
IPS.
* Additionally (UL) approved for use to brace Schedule 7
sprinkler pipe up to 4" (maximum horizontal design load
655 lbs.) Torque requirement 6 — 8 ft. lbs.
Material — Carbon Steel
Function — For bracing pipe against sway and seismic
disturbance. The pipe attachment component of a sway brace sys-
tem: Fig. 1000 is used in conjunction with a TOLCO
Fig. 900 Series Fitting and joined together with bracing pipe per
NFPA 13* or TOLCO OSHPD Approved Seismic Manual,
forming a complete sway brace assembly.
Features — Field adjustable, making critical pre-engineering of
bracing pipe unnecessary. Unique design requires no threading of
bracing pipe. Can be used as a component of a 4-way riser brace.
Can be used as longitudinal brace with Fig. 907. Comes assembled
and individually packaged with illustrated installation instructions
— sizes are clearly marked. Steel leaf spring insert provided to
assure installer and inspector necessary minimum torque has been
achieved.
Installation — The Fig. 1000 is the "braced pipe" attachment
component of a lateral sway brace assembly. It is intended to be Maximum Design Load
combined with the "bracing pipe" and TOLCO structural attach- 1" thru 4" pipe size — 2015 lbs.
ment component, Fig. 980, 910 or 909 to form a complete bracing 6" size — 1265 lbs.
assembly. Follow NFPA 13 and/or OSHPD guidelines.
To Install — Place the Fig. 1000 over the pipe to be braced, insert
bracing pipe through opening leaving a minimum of 1" extension. FM Approved Design Loads*
Brace pipe can be installed on top or bottom of pipe to be braced. 1" - 2½" - 600 lbs.
Tighten hex nuts until leaf spring is flat. It is recommended that the 3" - 4" - 700 lbs.
brace angle be adjusted before hex nuts are fully tightened.
Approvals — Underwriters Laboratories Listed in the USA (UL)
and Canada (cUL). Approved by Factory Mutual Engineering (FM).
Included in our Seismic Restraints Catalog approved by the State
of California Office of Statewide Health Planning and Development
(OSHPD). For additional load, spacing and placement informa-
tion relating to OSHPD projects, please refer to the TOLCO Seismic
Restraint Systems Guidelines.
Application Note — Position Fast Clamp and tighten two hex nuts
until leaf spring flattens. A minimum of 1" pipe extension beyond
the Fig. 1000 is recommended.
Finish — Plain
Note — Available in Electro-Galvanized and HDG finish or Stainless
Steel materials.
Order By — Order first by pipe size to be braced, followed by pipe
size used for bracing, figure number and finish.
Lateral Brace
TOLCO® brand bracing components are desgined to be compatible ONLY with other TOLCO® brand bracing components, resulting in a Listed
seismic bracing assembly. DISCLAIMER — NIBCO does NOT warrant against the failure of TOLCO® brand bracing components, in the instance
that such TOLCO® brand bracing components are used in combination with products, parts or systems which are not manufactured or sold under
the TOLCO® brand. NIBCO shall NOT be liable under any circumstance for any direct or indirect, incidental or consequential damages of any
kind, including but not limited to loss of business or profit, where non-TOLCO brand bracing components have been, or are used.
OFFICE/MANUFACTURING FACILITY • 1375 SAMPSON AVE. • CORONA, CA 92879 • PH: 951.737.5599 • FAX: 951.737.0330
CUSTOMER SERVICE • 800.786.5266 155
www.tolco.com