060fe1001239 Boundary Wall For St-Iv Silo Area Area - Balance Work
060fe1001239 Boundary Wall For St-Iv Silo Area Area - Balance Work
50
CONCERTINA WIRE
125
230 THICK BRICK WALL
75
PLASTERED BOTH SIDES
50
450
125
650
600
125
PLINTH BEAM 245X450
COPPING
125
3000
250
150
3000
COL. R/F 8-Y12 .Y8 @150 C/C
200
&5-Y8 DISTT.
RING 4 LEGGED Y8@200 C/C
250
PLINTH BEAM 245X500 75 THICK PCC 1:4:8
350
75
TOP AS MARKED ON LAYOUT DRG.
395 125 125
50
75
DRIP COURSE (TYP)
1275
Y12 @150C/C
RCC M25
200 BOTH WAYS
1-Y12 EXTRA BAR AT
END 1000 LONG
400
350
1800 650
150
75
PLINTH BEAM 10TH FOOTING SHALL BE
1200 245X500 1800 TWO COL. FOOTING 2-Y12 INNER R/F CONTINUOUS
115
RING Y8 @200 C/C COL. 245X400
450
1800
1800
12 PLASTER
50
400
125
5-Y8 Y 8 @ 150 C/C
15MM PLASTER
650
650
15MM PLASTER
125
SIDE TOP R/F Y12 (INNER CONTINUOUS)
116986
1200 1800
N
I/P 150X250X col. r/f
12THK Y12-8
25X6THK FLAT
LUGS 400 LONG col. r/f Y12-8
300 190
WELDED TO I/P
3000 6000
SILO (3Nos./PL.)
1800
1800
THERMOCOL
400
400
UTILITY
BUILDING
50
245 540
STORM WATER DRAIN
I/P 150X250X
6000 RAMP 1 IN 20 12THK
6000
25X6THK FLAT
LUGS 400 LONG
(3Nos./PL.)
2820x300x342 POCKETS (TYP.)
(INCL FLOOR FINISH)
. . . . .
2820
SILO SILO SILO VINDHYACHAL FIELD ENGINEERING
SILO 3 4
2 PROJECT
.
1 X C.L. OF
RAILS
(INCL FLOOR FINISH)
DRAIN
VINDHYACHAL SUPER THERMAL POWER PROJECT
SUMP
EXISTING SW DRAIN
TITLE
6950 15536 21500 21500 21500 18500 11500
BOUNDARY WALL FOR ST-IV SILO AREA
AREA- BALANCE WORK
DRG.NO. REV.NO.
060-FE-100-1239 0