Junos® OS

Chassis Cluster User Guide for SRX Series


Devices

Published

2023-10-04
ii

Juniper Networks, Inc.


1133 Innovation Way
Sunnyvale, California 94089
USA
408-745-2000
www.juniper.net

Juniper Networks, the Juniper Networks logo, Juniper, and Junos are registered trademarks of Juniper Networks, Inc.
in the United States and other countries. All other trademarks, service marks, registered marks, or registered service
marks are the property of their respective owners.

Juniper Networks assumes no responsibility for any inaccuracies in this document. Juniper Networks reserves the right
to change, modify, transfer, or otherwise revise this publication without notice.

Junos® OS Chassis Cluster User Guide for SRX Series Devices


Copyright © 2023 Juniper Networks, Inc. All rights reserved.

The information in this document is current as of the date on the title page.

YEAR 2000 NOTICE

Juniper Networks hardware and software products are Year 2000 compliant. Junos OS has no known time-related
limitations through the year 2038. However, the NTP application is known to have some difficulty in the year 2036.

END USER LICENSE AGREEMENT

The Juniper Networks product that is the subject of this technical documentation consists of (or is intended for use
with) Juniper Networks software. Use of such software is subject to the terms and conditions of the End User License
Agreement ("EULA") posted at https://support.juniper.net/support/eula/. By downloading, installing or using such
software, you agree to the terms and conditions of that EULA.
iii

Table of Contents
About This Guide | xx

1 Overview
Chassis Cluster Overview | 2

Chassis Cluster Overview | 2

Chassis Cluster Limitations | 5

Chassis Cluster Features Supported on SRX Series Devices | 8

2 Setting Up a Chassis Cluster


SRX Series Chassis Cluster Configuration Overview | 13

Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical
Interface Naming | 18

Preparing Your Equipment for Chassis Cluster Formation | 31

Connecting SRX Series Firewalls to Create a Chassis Cluster | 34

Example: Setting the Node ID and Cluster ID for Security Devices in a Chassis Cluster | 40

Requirements | 41

Overview | 42

Configuration | 42

Verification | 43

Chassis Cluster Management Interfaces | 44

Understanding Management Interface on an Active Chassis Cluster | 45

Example: Configuring the Chassis Cluster Management Interface | 46

Requirements | 46

Overview | 46

Configuration | 47

Verification | 53

Chassis Cluster Fabric Interfaces | 54


iv

Understanding Chassis Cluster Fabric Interfaces | 55

Example: Configuring the Chassis Cluster Fabric Interfaces | 60

Requirements | 61

Overview | 61

Configuration | 61

Verification | 63

Verifying Chassis Cluster Data Plane Interfaces | 64

Viewing Chassis Cluster Data Plane Statistics | 64

Clearing Chassis Cluster Data Plane Statistics | 65

Chassis Cluster Control Plane Interfaces | 67

Chassis Cluster Control Plane and Control Links | 67

Example: Configure Chassis Cluster Control Ports for Control Link | 71

Requirements | 72

Overview | 72

Configuration | 72

Clear Chassis Cluster Control Plane Statistics | 76

SCB Chassis Cluster Control Links | 76

Change from Chassis Cluster to Standalone Mode | 77

Example: Configure Control Ports Using the SCB Control Link | 78

Requirements | 78

Overview | 78

Configuration | 79

Verification | 80

Transition from SPC to SCB with a Single Control Link | 82

Requirements | 82

Overview | 83

Configuration | 83

Transition from SCB to SPC with a Single Control Link | 86

Requirements | 87

Configuration | 87
v

Chassis Cluster Redundancy Groups | 91

Understanding Chassis Cluster Redundancy Groups | 91

Example: Configuring Chassis Cluster Redundancy Groups | 95

Requirements | 96

Overview | 96

Configuration | 96
Verification | 98

Chassis Cluster Redundant Ethernet Interfaces | 99

Understanding Chassis Cluster Redundant Ethernet Interfaces | 100

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces | 103

Requirements | 104

Overview | 104

Configuration | 104

Verification | 109

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces on SRX4600 | 111

Requirements | 111

Overview | 112

Configuration | 112

Verification | 116

Example: Configuring IP-over-IP Tunnel on SRX Series Firewalls | 119

Requirements | 119

Overview | 119

Topology | 119

Configuration | 120

Verification | 125

Configuring Chassis Clustering on SRX Series Devices | 129

Example: Configure Chassis Clustering on SRX Series Firewalls | 130

Requirements | 131

Overview | 132

Configuration | 133

Verification | 142

Viewing a Chassis Cluster Configuration | 147


vi

Viewing Chassis Cluster Statistics | 148

Clearing Chassis Cluster Statistics | 150

Understanding Automatic Chassis Cluster Synchronization Between Primary and Secondary


Nodes | 151

Verifying Chassis Cluster Configuration Synchronization Status | 152

Example: Enabling Eight-Queue Class of Service on Redundant Ethernet Interfaces on


SRX Series Firewalls in a Chassis Cluster | 153

Requirements | 154

Overview | 154

Configuration | 156

Verification | 164

Conditional Route Advertisement over Redundant Ethernet Interfaces on SRX Series


Firewalls in a Chassis Cluster | 165

Understanding Conditional Route Advertising in a Chassis Cluster | 165

Example: Configuring Conditional Route Advertising in a Chassis Cluster | 166

Requirements | 166

Overview | 166

Configuration | 168

3 Configuring Redundancy and Failover in a Chassis Cluster


Chassis Cluster Dual Control Links | 172

Chassis Cluster Dual Control Links Overview | 172

Dual Control Link Connections for SRX Series Firewalls in a Chassis Cluster | 174

Upgrade the Second Routing Engine When Using Chassis Cluster Dual Control Links on
SRX5600 and SRX5800 Devices | 176

Example: Configure Chassis Cluster Control Ports for Dual Control Links | 178

Requirements | 178

Overview | 178

Configuration | 179

Verification | 180

Resiliency with SCB Dual Control Links | 181


vii

Example: Configure a Chassis Cluster Using SCB Dual Control Links | 184

Requirements | 184

Overview | 184

Configuration | 186

Verification | 187

Transition from SPC Dual Control Links to SCB Dual Control Links | 190

Requirements | 191

Overview | 191

Transition Procedure: SPC to SCB with Dual Control Links | 192

Transition from SCB to SPC with Dual Control Links | 196

Requirements | 197

Configuration | 197

Chassis Cluster Dual Fabric Links | 201

Understanding Chassis Cluster Dual Fabric Links | 201

Example: Configuring the Chassis Cluster Dual Fabric Links with Matching Slots and Ports | 202

Requirements | 202

Overview | 202

Configuration | 203

Verification | 205

Example: Configuring Chassis Cluster Dual Fabric Links with Different Slots and Ports | 206

Requirements | 206

Overview | 206

Configuration | 207

Verification | 208

Monitoring of Global-Level Objects in a Chassis Cluster | 209

Monitoring Chassis Cluster Interfaces | 214

Understanding Chassis Cluster Redundancy Group Interface Monitoring | 214

Example: Configuring Chassis Cluster Redundancy Group Interface Monitoring | 215

Requirements | 216

Overview | 216

Configuration | 217

Verification | 222
viii

Monitoring IP Addresses on a Chassis Cluster | 255

IP Monitoring Overview | 256

Understanding Chassis Cluster Redundancy Group IP Address Monitoring | 259

Example: Configuring Chassis Cluster Redundancy Group IP Address Monitoring | 261

Requirements | 261

Overview | 262
Configuration | 262

Verification | 265

Example: Configuring IP Monitoring on SRX5000 Line Devices for IOC2 and IOC3 | 266

Requirements | 266

Overview | 266

Configuration | 267

Verification | 274

Configuring Cluster Failover Parameters | 276

Understanding Chassis Cluster Control Link Heartbeats, Failure, and Recovery | 276

Example: Configuring Chassis Cluster Control Link Recovery | 279

Requirements | 279

Overview | 279

Configuration | 280

Understanding Chassis Cluster Resiliency | 281

Chassis Cluster Redundancy Group Failover | 282

Understanding Chassis Cluster Redundancy Group Failover | 283

Understanding Chassis Cluster Redundancy Group Manual Failover | 288

Initiating a Chassis Cluster Manual Redundancy Group Failover | 289

Example: Configuring a Chassis Cluster with a Dampening Time Between Back-to-Back


Redundancy Group Failovers | 292

Requirements | 292

Overview | 292

Configuration | 292

Understanding SNMP Failover Traps for Chassis Cluster Redundancy Group Failover | 293
ix

Verifying Chassis Cluster Failover Status | 294

Clearing Chassis Cluster Failover Status | 296

4 Chassis Cluster Operations


Aggregated Ethernet Interfaces in a Chassis Cluster | 298

Understanding Link Aggregation Groups in a Chassis Cluster | 298

Example: Configuring Link Aggregation Groups in a Chassis Cluster | 300

Requirements | 301

Overview | 301

Configuration | 302

Verification | 304

Understanding Link Aggregation Group Failover in a Chassis Cluster | 305

Understanding LACP on Chassis Clusters | 307

Example: Configuring LACP on Chassis Clusters | 310

Requirements | 311

Overview | 311

Configuration | 312

Verification | 318

Example: Configuring Chassis Cluster Minimum Links | 321

Requirements | 321

Overview | 321

Configuration | 322

Verification | 322

Example: Configuring Chassis Cluster Redundant Ethernet Interface Link Aggregation Groups on
an SRX5000 Line Device with IOC2 or IOC3 | 324

Requirements | 324

Overview | 324

Configuration | 325

Verification | 328

Understanding VRRP on SRX Series Firewalls | 329

VRRP failover-delay Overview | 332

Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant Ethernet Interfaces | 335


x

Requirements | 335

Overview | 336

Configuration VRRP | 337

Verification | 344

Example: Configuring VRRP for IPv6 | 347

Requirements | 347

Overview | 347
Configuring VRRP | 348

Verification | 355

NTP Time Synchronization on Chassis Cluster | 359

NTP Time Synchronization on SRX Series Devices | 360

Example: Simplifying Network Management by Synchronizing the Primary and Backup Nodes
with NTP | 360

Requirements | 361

Overview | 361

Configuration | 362

Verification | 364

Active/Passive Chassis Cluster Deployments | 367

Understanding Active/Passive Chassis Cluster Deployment | 368

Example: Configuring an Active/Passive Chassis Cluster on SRX5800 Firewalls | 369

Requirements | 369

Overview | 369

Configuration | 372

Verification | 379

Example: Configuring an Active/Passive Chassis Cluster Pair (SRX1500) | 387

Requirements | 387

Overview | 388

Configuration | 392

Verification | 398

Example: Configuring an Active/Passive Chassis Cluster Pair (J-Web) | 404

Understanding Active/Passive Chassis Cluster Deployment with an IPsec Tunnel | 406

Example: Configuring an Active/Passive Chassis Cluster Pair with an IPsec Tunnel | 408
xi

Requirements | 408

Overview | 409

Configuration | 415

Verification | 425

Example: Configuring an Active/Passive Chassis Cluster Pair with an IPsec Tunnel (J-Web) | 430

Multicast Routing and Asymmetric Routing on Chassis Cluster | 433

Understanding Multicast Routing on a Chassis Cluster | 434

Understanding Asymmetric Routing on a Chassis Cluster | 435

Example: Configuring an Asymmetric Chassis Cluster Pair | 437

Requirements | 438

Overview | 438

Configuration | 442

Verification | 449

Ethernet Switching on Chassis Cluster | 454

Layer 2 Ethernet Switching Capability in a Chassis Cluster Mode | 455

Example: Configuring Switch Fabric Interfaces to Enable Switching in Chassis Cluster Mode on a
Security Device | 456

Requirements | 456

Overview | 457

Configuration | 457

Example: Configure IRB and VLAN with Members Across Two Nodes on a Security Device using
Tagged | 460

Requirements | 460

Overview | 460

Configuration | 461

Example: Configure IRB and VLAN with Members Across Two Nodes on a Security Device using
Untagged Traffic | 470

Requirements | 470

Overview | 470

Configuration | 471

Example: Configuring VLAN with Members Across Two Nodes on a Security Device | 480

Requirements | 480
xii

Overview | 480

Configuration | 480

Verification | 483

Media Access Control Security (MACsec) on Chassis Cluster | 485

Understanding Media Access Control Security (MACsec) | 486

Configuring Media Access Control Security (MACsec) | 489


Configuration Considerations When Configuring MACsec on Chassis Cluster Setup | 489

Configuring MACsec Using Static Connectivity Association Key Security Mode | 491

Configuring Static CAK on the Chassis Cluster Control Port | 496

Configuring Static CAK on the Chassis Cluster Fabric Port | 497

Configuring Static CAK on the Control Port of SRX4600 Device in Chassis Cluster | 498

Verifying MACSEC Configuration | 499

Understanding SCTP Behavior in Chassis Cluster | 505

Example: Encrypting Messages Between Two Nodes in a Chassis Cluster | 505

5 Upgrading or Disabling a Chassis Cluster


Upgrading Individual Devices in a Chassis Cluster Separately | 509

Upgrading Devices in a Chassis Cluster Using ICU | 509

Upgrading Both Devices in a Chassis Cluster Using ICU | 510

Upgrading ICU Using a Build Available Locally on a Primary Node in a Chassis Cluster | 511

Upgrading ICU Using a Build Available on an FTP Server | 512

Terminating an Upgrade in a Chassis Cluster During an ICU | 513

Upgrading a Chassis Cluster Using In-Service Software Upgrade | 514

Understanding ISSU for a Chassis Cluster | 515

ISSU System Requirements | 518

Upgrading Both Devices in a Chassis Cluster Using ISSU | 519

Rolling Back Devices in a Chassis Cluster After an ISSU | 521

Enabling an Automatic Chassis Cluster Node Failback After an ISSU | 522

Log Error Messages used for Troubleshooting ISSU-Related Problems | 522


xiii

Chassisd Process Errors | 522

Understanding Common Error Handling for ISSU | 523

ISSU Support-Related Errors | 527

Initial Validation Checks Failure | 527

Installation-Related Errors | 529

Redundancy Group Failover Errors | 530

Kernel State Synchronization Errors | 531

Managing Chassis Cluster ISSU-Related Problems | 531

Viewing ISSU Progress | 532

Stopping ISSU Process if it Halts During an Upgrade | 533

Recovering the Node in Case of a Failed ISSU | 534

Disabling a Chassis Cluster | 536

6 Troubleshooting
Troubleshooting a Control Link Failure in an SRX Chassis Cluster | 539

Troubleshooting a Fabric Link Failure in an SRX Chassis Cluster | 541

Troubleshooting a Redundancy Group that Does Not Fail Over in an SRX Chassis
Cluster | 544

Troubleshooting an SRX Chassis Cluster with One Node in the Primary State and the
Other Node in the Disabled State | 549

Troubleshooting an SRX Chassis Cluster with One Node in the Primary State and the
Other Node in the Lost State | 553

Troubleshooting an SRX Chassis Cluster with One Node in the Hold State and the Other
Node in the Lost State | 556

Troubleshooting Chassis Cluster Management Issues | 560

Unable to Manage an SRX Series Chassis Cluster Using the Management Port or Revenue
Ports | 560

Unable to Manage the Secondary Node of a Chassis Cluster Using J-Web | 572

Unable to Manage an SRX Series Chassis Cluster Using fxp0 When the Destination in the
Backup Router is 0/0 | 574

Unable to Upgrade a Chassis Cluster Using In-Service Software Upgrade | 580

Configuring backup-router Command on Chassis Cluster | 582


xiv

Unable to Upgrade a Chassis Cluster Using In-Service Software Upgrade | 583

Data Collection for Customer Support | 585

7 Configuration Statements
aggregated-devices | 590

apply-groups (Chassis Cluster) | 592

arp-detect | 594

arp-throttle | 596

authentication-key | 598

authentication-type | 600

cak | 602

ckn | 604

cluster (Chassis) | 606

configuration-synchronize (Chassis Cluster) | 610

connectivity-association | 612

connectivity-association (MACsec Interfaces) | 614

control-link-recovery | 616

control-ports | 617

exclude-protocol | 619

fabric-options | 621

gigether-options (Chassis Cluster) | 624

global-threshold | 626

global-weight | 628

gratuitous-arp-count | 630

heartbeat-interval | 632

heartbeat-threshold | 634
xv

hold-down-interval | 636

include-sci | 637

interface (Chassis Cluster) | 639

interfaces (MACsec) | 641

interface-monitor | 643

internal (Security IPsec) | 645

ip-monitoring | 647

key-server-priority (MACsec) | 650

lacp (Interfaces) | 652

link-protection (Chassis Cluster) | 654

macsec | 656

mka | 659

network-management | 661

no-encryption (MACsec) | 663

node (Chassis Cluster Redundancy Group) | 665

ntp | 667

ntp threshold | 675

offset | 677

preempt (Chassis Cluster) | 679

pre-shared-key | 682

priority (Protocols VRRP) | 684

redundancy-group (Chassis Cluster) | 686

redundant-ether-options | 689

redundant-parent (Interfaces) | 692

redundant-pseudo-interface-options | 693
xvi

replay-protect | 695

replay-window-size | 697

resource-watch | 699

reth-count (Chassis Cluster) | 702

retry-count (Chassis Cluster) | 704

retry-interval (Chassis Cluster) | 706

route-active-on | 708

scb-control-ports | 709

security-mode | 711

traceoptions (Chassis Cluster) | 713

transmit-interval (MACsec) | 716

use-active-child-mac-on-reth | 718

use-actual-mac-on-physical-interfaces | 719

virtual-address | 720

vrrp-group | 722

weight | 726

8 Operational Commands
clear chassis cluster control-plane statistics | 732

clear chassis cluster data-plane statistics | 733

clear chassis cluster failover-count | 735

clear chassis cluster ip-monitoring failure-count | 737

clear chassis cluster ip monitoring failure count ip address | 739

clear chassis cluster statistics | 741

request chassis cb | 742

request chassis cluster configuration-synchronize | 745


xvii

request chassis cluster failover node | 746

request chassis cluster failover redundancy-group | 748

request chassis cluster failover reset | 750

request chassis fpc | 752

request chassis fpc-control-port | 755

request chassis cluster in-service-upgrade abort (ISSU) | 757

request chassis primary-ha-control-port-transition | 759

request security internal-security-association refresh | 761

request system scripts add | 763

request system reboot (SRX Series) | 768

request system software in-service-upgrade (Maintenance) | 770

OBSOLETE: request system software rollback (SRX Series) | 776

set chassis cluster disable reboot | 778

set chassis cluster cluster-id node node-number reboot | 780

show chassis cluster control-plane statistics | 782

show chassis cluster data-plane interfaces | 786

show chassis cluster data-plane statistics | 788

show chassis cluster ethernet-switching interfaces | 791

show chassis cluster ethernet-switching status | 793

show chassis cluster information | 796

show chassis cluster information configuration-synchronization | 803

show chassis cluster information issu | 806

show chassis cluster interfaces | 808

show chassis cluster ip-monitoring status redundancy-group | 818

show chassis cluster statistics | 822


xviii

show chassis cluster status | 829

show chassis environment (Security) | 834

show chassis environment cb | 842

show chassis ethernet-switch | 847

show chassis fabric plane | 854

show chassis fabric plane-location | 862

show chassis fabric summary | 865

show chassis hardware (View) | 868

show chassis routing-engine (View) | 889

show chassis reswatch | 896

show chassis scb-ha-port | 898

show chassis temperature-thresholds | 903

show configuration chassis cluster traceoptions | 906

show interfaces (SRX Series) | 908

set date ntp | 957

show system ntp threshold | 959

show security macsec connections | 961

show security macsec statistics (SRX Series Firewalls) | 964

show security mka statistics | 970

show security mka sessions (SRX Series Device | 974

show security internal-security-association | 977

show system license (View) | 979

show vrrp | 984

Chassis Cluster Support on SRX100, SRX210, SRX220, SRX240, SRX650,


9 SRX1400, SRX3400, and SRX3600 Devices
xix

Chassis Cluster Support on SRX100, SRX210, SRX220, SRX240, SRX650, SRX1400,


SRX3400, and SRX3600 Devices | 1000
xx

About This Guide

Use this guide to configure and operate the SRX Series Firewalls in chassis cluster mode, where a pair of
devices are connected and configured to operate as a single node, providing device, interface, and
service level redundancy.
1 CHAPTER

Overview

Chassis Cluster Overview | 2

Chassis Cluster Features Supported on SRX Series Devices | 8


2

Chassis Cluster Overview

IN THIS SECTION

Chassis Cluster Overview | 2

Chassis Cluster Limitations | 5

A chassis cluster provides high availability on SRX Series Firewalls where two devices operate as a single
device. Chassis cluster includes the synchronization of configuration files and the dynamic runtime
session states between the SRX Series Firewalls, which are part of chassis cluster setup.

Chassis Cluster Overview

IN THIS SECTION

Benefits of Chassis Cluster | 3

Chassis Cluster Functionality | 3

Chassis Cluster Modes | 3

How Chassis Clustering Works? | 4

IPv6 Clustering Support | 4

The Junos OS provides high availability on SRX Series Firewall by using chassis clustering. SRX Series
Firewalls can be configured to operate in cluster mode, where a pair of devices can be connected
together and configured to operate like a single node, providing device, interface, and service level
redundancy.

For SRX Series Firewalls, which act as stateful firewalls, it is important to preserve the state of the traffic
between two devices. In a chassis cluster setup, in the event of failure, session persistence is required so
that the established sessions are not dropped even if the failed device was forwarding traffic.

When configured as a chassis cluster, the two nodes back up each other, with one node acting as the
primary device and the other as the secondary device, ensuring stateful failover of processes and
3

services in the event of system or hardware failure. If the primary device fails, the secondary device
takes over the processing of traffic. The cluster nodes are connected together with two links called
control link and fabric link and devices in a chassis cluster synchronize the configuration, kernel, and PFE
session states across the cluster to facilitate high availability, failover of stateful services, and load
balancing.

There is no seperate license required to enable chassis cluster. However, some Junos OS software
features require a license to activate the feature. For more information, see Understanding Chassis
Cluster Licensing Requirements, Installing Licenses on the SRX Series Devices in a Chassis Cluster and
Verifying Licenses on an SRX Series Device in a Chassis Cluster. Please refer to the Juniper Licensing
Guide for general information about License Management. Please refer to the product Data Sheets at
SRX Series Services Gateways for details, or contact your Juniper Account Team or Juniper Partner.

Benefits of Chassis Cluster

• Prevents single device failure that results in a loss of connectivity.

• Provides high availability between devices when connecting branch and remote site links to larger
corporate offices. By leveraging the chassis cluster feature, enterprises can ensure connectivity in the
event of device or link failure.

Chassis Cluster Functionality

Chassis cluster functionality includes:

• Resilient system architecture, with a single active control plane for the entire cluster and multiple
Packet Forwarding Engines. This architecture presents a single device view of the cluster.

• Synchronization of configuration and dynamic runtime states between nodes within a cluster.

• Monitoring of physical interfaces, and failover if the failure parameters cross a configured threshold.

Chassis Cluster Modes

A chassis cluster can be configured in an active/active or active/passive mode.

• Active/passive mode: In active/passive mode, transit traffic passes through the primary node while
the backup node is used only in the event of a failure. When a failure occurs, the backup device
becomes primary and takes over all forwarding tasks.

• Active/active mode: In active/active mode, has transit traffic passing through both nodes of the
cluster all of the time.
4

How Chassis Clustering Works?

The control ports on the respective nodes are connected to form a control plane that synchronizes
configuration and kernel state to facilitate the high availability of interfaces and services.

The data plane on the respective nodes is connected over the fabric ports to form a unified data plane.

When creating a chassis cluster, the control ports on the respective nodes are connected to form a
control plane that synchronizes the configuration and kernel state to facilitate the high availability of
interfaces and services.

Similarly, the data plane on the respective nodes is connected over the fabric ports to form a unified
data plane.

The fabric link allows for the management of cross-node flow processing and for the management of
session redundancy.

The control plane software operates in active or backup mode. When configured as a chassis cluster, the
two nodes back up each other, with one node acting as the primary device and the other as the
secondary device, ensuring stateful failover of processes and services in the event of system or
hardware failure. If the primary device fails, the secondary device takes over processing of traffic.

The data plane software operates in active/active mode. In a chassis cluster, session information is
updated as traffic traverses either device, and this information is transmitted between the nodes over
the fabric link to guarantee that established sessions are not dropped when a failover occurs. In active/
active mode, it is possible for traffic to ingress the cluster on one node and egress from the other node.
When a device joins a cluster, it becomes a node of that cluster. With the exception of unique node
settings and management IP addresses, nodes in a cluster share the same configuration.

At any given instant, a cluster can be in one of the following states: hold, primary, secondary-hold,
secondary, ineligible, and disabled. A state transition can be triggered because of any event, such as
interface monitoring, SPU monitoring, failures, and manual failovers.

IPv6 Clustering Support

SRX Series Firewalls running IP version 6 (IPv6) can be deployed in active/active (failover) chassis cluster
configurations in addition to the existing support of active/passive (failover) chassis cluster
configurations. An interface can be configured with an IPv4 address, IPv6 address, or both. Address
book entries can include any combination of IPv4 addresses, IPv6 addresses, and Domain Name System
(DNS) names.

Chassis cluster supports Generic Routing Encapsulation (GRE) tunnels used to route encapsulated IPv4/
IPv6 traffic by means of an internal interface, gr-0/0/0. This interface is created by Junos OS at system
bootup and is used only for processing GRE tunnels. See the Interfaces User Guide for Security Devices.
5

Chassis Cluster Limitations

The SRX Series Firewalls have the following chassis cluster limitations:

Chassis Cluster

• Group VPN is not supported.

• On all SRX Series Firewalls in a chassis cluster, flow monitoring for version 5 and version 8 is
supported. However, flow monitoring for version 9 is not supported.

• When an SRX Series Firewall is operating in chassis cluster mode and encounter any IA-chip access
issue in an SPC or a I/O Card (IOC), a minor FPC alarm is activated to trigger redundancy group
failover.

• On SRX5400, SRX5600, and SRX5800 devices, screen statistics data can be gathered on the primary
device only.

• On SRX4600, SRX5400, SRX5600, and SRX5800 devices, in large chassis cluster configurations, if
more than 1000 logical interfaces are used, the cluster heartbeat timers are recommended to be
increased from the default wait time before triggering failover. In a full-capacity implementation, we
recommend increasing the wait to 8 seconds by modifying heartbeat-threshold and heartbeat-interval
values in the [edit chassis cluster] hierarchy.

The product of the heartbeat-threshold and heartbeat-interval values defines the time before failover.
The default values (heartbeat-threshold of 3 beats and heartbeat-interval of 1000 milliseconds) produce a
wait time of 3 seconds.

To change the wait time, modify the option values so that the product equals the desired setting. For
example, setting the heartbeat-threshold to 8 and maintaining the default value for the heartbeat-interval
(1000 milliseconds) yields a wait time of 8 seconds. Likewise, setting the heartbeat-threshold to 4 and
the heartbeat-interval to 2000 milliseconds also yields a wait time of 8 seconds.

• On SRX5400, SRX5600, and SRX5800 devices, eight-queue configurations are not reflected on the
chassis cluster interface.

Flow and Processing

• If you use packet capture on reth interfaces, two files are created, one for ingress packets and the
other for egress packets based on the reth interface name. These files can be merged outside of the
device using tools such as Wireshark or Mergecap.

• If you use port mirroring on reth interfaces, the reth interface cannot be configured as the output
interface. You must use a physical interface as the output interface. If you configure the reth
interface as an output interface using the set forwarding-options port-mirroring family inet output
command, the following error message is displayed.
6

Port-mirroring configuration error.


Interface type in reth1.0 is not valid for port-mirroring or next-hop-group config

• When an SRX Series Firewall is operating in chassis cluster mode and encounter any IA-chip (IA-chip
is part of Juniper SPC1 and IOC1. It has direct impact on SPC1/IOC1 control plane) access issue in an
SPC or a I/O Card (IOC), a minor FPC alarm is activated to trigger redundancy group failover.

• On SRX Series Firewalls in a chassis cluster, when two logical systems are configured, the scaling limit
crosses 13,000, which is very close to the standard scaling limit of 15,000, and a convergence time of
5 minutes results. This issue occurs because multicast route learning takes more time when the
number of routes is increased.

• On SRX4600, SRX5400, SRX5600, and SRX5800 devices in a chassis cluster, if the primary node
running the LACP process (lacpd) undergoes a graceful or ungraceful restart, the lacpd on the new
primary node might take a few seconds to start or reset interfaces and state machines to recover
unexpected synchronous results. Also, during failover, when the system is processing traffic packets
or internal high-priority packets (deleting sessions or reestablishing tasks), medium-priority LACP
packets from the peer (switch) are pushed off in the waiting queues, causing further delay.

Flowd monitoring is supported on SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M, and
SRX1500 devices.

Installation and Upgrade

• For SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices, the reboot parameter is not
available, because the devices in a cluster are automatically rebooted following an in-band cluster
upgrade (ICU).

Interfaces

• On the lsq-0/0/0 interface, Link services MLPPP, MLFR, and CRTP are not supported.

• On the lt-0/0/0 interface, CoS for RPM is not supported.

• The 3G dialer interface is not supported.

• Queuing on the ae interface is not supported.

Layer 2 Switching

• On SRX Series Firewall failover, access points on the Layer 2 switch reboot and all wireless clients
lose connectivity for 4 to 6 minutes.

MIBs

• The Chassis Cluster MIB is not supported.

Monitoring
7

• The maximum number of monitoring IPs that can be configured per cluster is 64 for SRX300,
SRX320, SRX340, SRX345, SRX380, SRX550M, and SRX1500 devices.

• On SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M, and SRX1500 devices, logs cannot be
sent to NSM when logging is configured in the stream mode. Logs cannot be sent because the
security log does not support configuration of the source IP address for the fxp0 interface and the
security log destination in stream mode cannot be routed through the fxp0 interface. This implies
that you cannot configure the security log server in the same subnet as the fxp0 interface and route
the log server through the fxp0 interface.

IPv6

• Redundancy group IP address monitoring is not supported for IPv6 destinations.

GPRS

• On SRX5400, SRX5600, and SRX5800 devices, an APN or an IMSI filter must be limited to 600 for
each GTP profile. The number of filters is directly proportional to the number of IMSI prefix entries.
For example, if one APN is configured with two IMSI prefix entries, then the number of filters is two.

MIBs

• The Chassis Cluster MIB is not supported.

Nonstop Active Routing (NSR)

• NSR can preserve interface and kernel information and saves routing protocol information by running
the routing protocol process (RPD) on the backup Routing Engine. However, most SRX platforms do
not support NSR yet. So on the secondary node, there is no existing RPD daemon. After RG0 failover
happens, the new RG0 master will have a new RPD and need to re-negotiate with peer device. Only
SRX5000 platforms with version 17.4R2 or higher can support NSR.

Starting with Junos OS Release 12.1X45-D10 and later, sampling features such as flow monitoring,
packet capture, and port mirroring are supported on reth interfaces.

SEE ALSO

Preparing Your Equipment for Chassis Cluster Formation | 31

Release History Table

Release Description

12.1X45 Starting with Junos OS Release 12.1X45-D10 and later, sampling features such as flow monitoring,
packet capture, and port mirroring are supported on reth interfaces.
8

RELATED DOCUMENTATION

SRX Series Chassis Cluster Configuration Overview | 13


Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming | 18
Example: Configure Chassis Clustering on SRX Series Firewalls | 130

Chassis Cluster Features Supported on SRX Series


Devices

IN THIS SECTION

Supported Features on Standalone and Chassis Cluster | 8

To determine if a feature is supported by a specific platform or Junos OS release, refer to Feature


Explorer.

Supported Features on Standalone and Chassis Cluster

All features are supported in both chassis cluster and standalone mode on the same platform, except
what is indicated in the below table.

Table 1 on page 8 lists the features that are not supported in standalone or chassis cluster.

Table 1: Features Not Supported in Standalone or Chassis Cluster

Category Features Standalone Chassis cluster

Ethernet Link LACP (port priority) Layer 3 Yes


Aggregation Mode
Not supported in Active/Backup and
LACP (port priority) Layer 2 Active/Active modes.
Mode
9

Table 1: Features Not Supported in Standalone or Chassis Cluster (Continued)

Category Features Standalone Chassis cluster

Diagnostics Tools J-Flow Yes Yes

Ping MPLS Not supported in Active/Active and


Active/Active Failover mode. But
state is synched to backup node.

Ethernet Interfaces Promiscuous mode on Ethernet Yes


interface

Chassis Management Chassis cluster SPC insert Yes Yes

IEEE 802.3af/ 802.3at support Not supported in Active/Backup,


Active/Backup Failover, Active/
Active, Active/Active Failover.

Class of Service Simple filters Yes

Table 1: Features Not Supported in Standalone or Chassis Cluster (Continued)

Flow-Based and Packet- End-to-end packet debugging Yes


Based Processing-
Express Path support

Host bound fragmented traffic

Packet-based processing

Selective stateless packet-based services

GPRS GPRS (transparent mode and route mode) Yes

Multicast VPN Basic multicast features in C-instance Yes

Multicast VPN membership discovery with BGP

P2MP LSP support

P2MP OAM to P2MP LSP ping

Reliable multicast VPN routing information exchange


10

GTPv2 IMSI prefix and APN filtering Yes

Message-length filtering

Message-rate limiting

Message-type filtering

Packet sanity check

Policy-based inspection

Restart GTPv2 path

Sequence-number and GTP-U validation

Stateful inspection

Traffic logging

Tunnel cleanup

IDP Cryptographic key handling Yes

DSCP marking

IDP class-of-service action

IDP inline tap mode

IDP SSL inspection

Jumbo frames

Performance and capacity tuning for IDP

Layer 2 Mode Q-in-Q tunneling Yes

SNMP v1,v2,v3 Yes

Stateless Firewall Filters Stateless firewall filters(ACLs) Yes

Transparent Mode Bridge domain Yes


11

UTM Antivirus–Express Yes

Antivirus–Full Not supported in


Active/Backup Failover
Stateful active/active cluster mode and Active/Active
Failover modes.
Web filtering–Websense redirect

User Interfaces J-Web user interface Yes

Junos XML protocol

Session and Resource Control (SRC) application

Upgrading and Rebooting ISSU No Yes

RELATED DOCUMENTATION

Chassis Cluster Overview | 2


2 CHAPTER

Setting Up a Chassis Cluster

SRX Series Chassis Cluster Configuration Overview | 13

Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and
Logical Interface Naming | 18

Preparing Your Equipment for Chassis Cluster Formation | 31

Connecting SRX Series Firewalls to Create a Chassis Cluster | 34

Example: Setting the Node ID and Cluster ID for Security Devices in a Chassis
Cluster | 40

Chassis Cluster Management Interfaces | 44

Chassis Cluster Fabric Interfaces | 54

Chassis Cluster Control Plane Interfaces | 67

Chassis Cluster Redundancy Groups | 91

Chassis Cluster Redundant Ethernet Interfaces | 99

Configuring Chassis Clustering on SRX Series Devices | 129

Example: Enabling Eight-Queue Class of Service on Redundant Ethernet Interfaces


on SRX Series Firewalls in a Chassis Cluster | 153

Conditional Route Advertisement over Redundant Ethernet Interfaces on SRX


Series Firewalls in a Chassis Cluster | 165
13

SRX Series Chassis Cluster Configuration Overview

Following are the prerequisites for configuring a chassis cluster:

• On SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M any existing configurations
associated with interfaces that transform to the fxp0 management port and the control port should
be removed. For more information, see "Understanding SRX Series Chassis Cluster Slot Numbering
and Physical Port and Logical Interface Naming" on page 18.

• Confirm that hardware and software are the same on both devices.

• Confirm that license keys are the same on both devices.

• For SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M chassis clusters, the placement and
type of GPIMs, XGPIMs, XPIMs, and Mini-PIMs (as applicable) must match in the two devices.

• For SRX5000 line chassis clusters, the placement and type of SPCs must match in the two devices.

Figure 1 on page 14 shows a chassis cluster flow diagram for SRX300, SRX320, SRX340, SRX345,
SRX380, SRX550M, SRX1500, SRX4100, SRX4200, and SRX4600 devices.
14

Figure 1: Chassis Cluster Flow Diagram (SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M,
SRX1500, SRX4100, SRX4200, and SRX4600 Devices)
15

Figure 2: Chassis Cluster Flow Diagram (SRX5800, SRX5600, SRX5400 Devices)

This section provides an overview of the basic steps to create an SRX Series chassis cluster. To create an
SRX Series chassis cluster:

1. Prepare the SRX Series Firewalls to be used in the chassis cluster. For more information, see
"Preparing Your Equipment for Chassis Cluster Formation" on page 31.
16

2. Physically connect a pair of the same kind of supported SRX Series Firewalls together. For more
information, see "Connecting SRX Series Devices to Create a Chassis Cluster" on page 34.

a. Create the fabric link between two nodes in a cluster by connecting any pair of Ethernet
interfaces. For most SRX Series Firewalls, the only requirement is that both interfaces be Gigabit
Ethernet interfaces (or 10-Gigabit Ethernet interfaces).

When using dual fabric link functionality, connect the two pairs of Ethernet interfaces that you
will use on each device. See "Understanding Chassis Cluster Dual Fabric Links" on page 201.

b. Configure the control ports (SRX5000 line only). See "Example: Configuring Chassis Cluster
Control Ports" on page 71.
3. Connect the first device to be initialized in the cluster to the console port. This is the node (node 0)
that forms the cluster and use CLI operational mode commands to enable clustering:

a. Identify the cluster by giving it the cluster ID.

b. Identify the node by giving it its own node ID and then reboot the system.

See "Example: Setting the Node ID and Cluster ID for Security Devices in a Chassis Cluster " on page
40. For connection instructions, see the Getting Started Guide for your device
4. Connect to the console port on the other device (node 1) and use CLI operational mode commands
to enable clustering:

a. Identify the cluster that the device is joining by setting the same cluster ID you set on the first
node.

b. Identify the node by giving it its own node ID and then reboot the system.
5. Configure the management interfaces on the cluster. See "Example: Configuring the Chassis Cluster
Management Interface" on page 46.
6. Configure the cluster with the CLI. See the following topics:

a. Example: Configuring the Number of Redundant Ethernet Interfaces in a Chassis Cluster

b. "Example: Configuring the Chassis Cluster Fabric Interfaces" on page 60

c. "Example: Configuring Chassis Cluster Redundancy Groups" on page 95

d. "Example: Configuring Chassis Cluster Interface Monitoring" on page 215

e. "Example: Configuring Chassis Clustering on an SRX Series Devices" on page 130


7. (Optional) Initiate manual failover. See "Initiating a Chassis Cluster Manual Redundancy Group
Failover" on page 289.
8. (Optional) Configure conditional route advertisement over redundant Ethernet interfaces. See
"Understanding Conditional Route Advertising in a Chassis Cluster" on page 165.
9. Verify the configuration. See "Viewing a Chassis Cluster Configuration" on page 147.
17

If two nodes are connected in cluster, one node is elected as primary mode and its Routing Engine is
running as primary. The Routing Engine in secondary node running as client. All FPCs in the cluster,
regardless in primary node or secondary node, connect to the primary Routing Engine. The FPCs on
secondary node connect to primary Routing Engine through the HA control link. If the cluster has two
primaries, IOC receives a message from a different primary and reboot itself to recover from this error
state.

To prevent the IOC card from rebooting, secondary node has to be powered off before connecting into
the cluster.

To preserve the traffic on primary while connecting the secondary node into cluster, it is recommended
to configure cluster mode on node 1 and power down before connecting it to the cluster to avoid any
impact to the primary. The reason here is that control networks are different for a HA cluster or a single
node system. When the control ports are connected, these two join the same network and they
exchange messages.

This section provides an overview of the basic steps to restore the backup node after a failure when
there is a running primary node:

1. Connect to the console port on the other device (node 1) and use CLI operational mode commands
to enable clustering:

a. Identify the cluster that the device is joining by setting the same cluster ID you set on the first
node.

b. Identify the node by giving it its own node ID and then reboot the system.

See "Example: Setting the Node ID and Cluster ID for Security Devices in a Chassis Cluster " on page
40. For connection instructions, see the Getting Started Guide for your device

2. Power off the secondary node.

3. Connect the HA control ports between two nodes.

4. Power on the secondary node.

5. The cluster is re-formed and the session is synced to the secondary node.

• When using dual fabric link functionality, connect the two pairs of Ethernet interfaces that you will
use on each device. See "Understanding Chassis Cluster Dual Fabric Links" on page 201.

• When using dual control link functionality (SRX5600 and SRX5800 devices only), connect the two
pairs of control ports that you will use on each device.

See "Dual Control Link Connections for SRX Series Firewalls in a Chassis Cluster" on page 174.

For SRX5600 and SRX5800 devices, control ports must be on corresponding slots in the two devices.
Table 2 on page 18 shows the slot numbering offsets:
18

Table 2: Slot Numbering Offsets

Device Offset

SRX5800 12 (for example, fpc3 and fpc15)

SRX5600 6 (for example, fpc3 and fpc9)

SRX5400 3 (for example, fpc3 and fpc6)

SRX4600 7 (for example, fpc1 and fpc8)

• On SRX3400 and SRX3600 devices, the control ports are dedicated Gigabit Ethernet ports.

• On SRX4600 devices, the control ports and fabric ports are dedicated 10-Gigabit Ethernet ports.

RELATED DOCUMENTATION

Chassis Cluster Overview | 2

Understanding SRX Series Chassis Cluster Slot


Numbering and Physical Port and Logical Interface
Naming

IN THIS SECTION

Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming for SRX300, SRX320,
SRX340, SRX345, SRX380, SRX550M, and SRX1500 Devices | 19

Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming for SRX4600 Devices | 23

Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming for SRX4100 and SRX4200
Devices | 25
19

Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming for SRX5800, SRX5600, and
SRX5400 Devices | 27

FPC Slot Numbering in SRX Series Firewall Cards | 30

See the hardware documentation for your particular model (SRX Series Services Gateways) for details
about SRX Series Firewalls. See Interfaces User Guide for Security Devices for a full discussion of
interface naming conventions.

After the devices are connected as a cluster, the slot numbering on the SRX acting as node 1 changes
and thus the interface numbering will change. The slot number for each slot in both nodes is determined
using the following formula:

cluster slot number = (node ID * maximum slots per node) + local slot number

In chassis cluster mode, the interfaces on the SRX acting as node 1 are renumbered internally.

This topic describes the slot numbering and physical port and logical interface naming conventions for
SRX Series Firewalls in a chassis cluster and includes following sections:

Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming for SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M, and
SRX1500 Devices

For SRX340 and SRX345 devices, the fxp0 interface is a dedicated port. For SRX300 and SRX320
devices, after you enable chassis clustering and reboot the system, the built-in interface named
ge-0/0/0 is repurposed as the management interface and is automatically renamed fxp0.

For SRX300, SRX320, SRX340, SRX345, and SRX380 devices, after you enable chassis clustering and
reboot the system, the build-in interface named ge-0/0/1 is repurposed as the control interface and is
automatically renamed fxp1. The SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M support only
Gigabit Ethernet ports as fabric link.

For SRX550M devices, control interfaces are dedicated Gigabit Ethernet ports.

SRX1500 devices have 16 GE interfaces and 4 XE ports.

Table 3 on page 20 shows the slot numbering, as well as the physical port and logical interface
numbering, for both of the SRX Series Firewalls that become node 0 and node 1 of the chassis cluster
after the cluster is formed.
20

Table 3: Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming

Model Chassis Maximum Slot Management Control Fabric


Slots Per Numbering in Physical Physical Physical
Node a Cluster Port/Logical Port/Logical Port/Logical
Interface Interface Interface

SRX1500 Node 0 3 0 fxp0 Dedicated Any Ethernet


Control port port

em0 fab0

Node 1 7 fxp0 Dedicated Any Ethernet


Control port port

em0 fab1

SRX340,SRX Node 0 5 (PIM slots) 0—4 fxp0 ge-0/0/1 Any Ethernet


345, and port
SRX380

fxp0 fxp1 fab0

Node 1 5—9 fxp0 ge-5/0/1 Any Ethernet


port

fxp0 fxp1 fab1

SRX320 Node 0 3 (PIM slots) 0—2 ge-0/0/0 ge-0/0/1 Any Ethernet


port

fxp0 fxp1 fab0

Node 1 3—5 ge-3/0/0 ge-3/0/1 Any Ethernet


port

fxp0 fxp1 fab1


21

Table 3: Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming (Continued)

Model Chassis Maximum Slot Management Control Fabric


Slots Per Numbering in Physical Physical Physical
Node a Cluster Port/Logical Port/Logical Port/Logical
Interface Interface Interface

SRX300 Node 0 1(PIM slot) 0 ge-0/0/0 ge-0/0/1 Any Ethernet


port

fxp0 fxp1 fab0

Node 1 1 ge-1/0/0 ge-1/0/1 Any Ethernet


port

fxp0 fxp1 fab1

SRX550M Node 0 9 (PIM slots) 0—8 ge-0/0/0 ge-0/0/1 Any Ethernet


port

fxp0 fxp1 fab0

Node 1 9—17 ge-9/0/0 ge-9/0/1 Any Ethernet


port

fxp0 fxp1 fab1

After you enable chassis clustering, the two chassis joined together cease to exist as individuals and now
represent a single system. As a single system, the cluster now has twice as many slots. (See Figure 3 on
page 21, Figure 4 on page 22, Figure 5 on page 22, Figure 6 on page 22, and Figure 9 on page 23.)

Figure 3: Slot Numbering in SRX300 Chassis Cluster


22

Figure 4: Slot Numbering in SRX320 Chassis Cluster

Figure 5: Slot Numbering in SRX340 Chassis Cluster

Figure 6: Slot Numbering in SRX345 Chassis Cluster

Figure 7: Slot Numbering in SRX380 Chassis Cluster


23

Figure 8: Slot Numbering for SRX550M Devices

Figure 9: Slot Numbering in SRX1500 Chassis Cluster

Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming for SRX4600 Devices

The SRX4600 devices use dedicated HA control and fabric ports.

Table 4 on page 24 and Table 5 on page 24 show the slot numbering, as well as the physical port and
logical interface numbering, for both of the SRX Series Firewalls that become node 0 and node 1 of the
chassis cluster after the cluster is formed.

For information on SRX3400 and SRX3600 devices, see Chassis Cluster support on SRX3400 and
SRX3600 devices.
24

Table 4: Chassis Cluster Slot Numbering, and Physical Port and Logical Interface Naming for SRX4600
Devices

Model Chassis Maximu Slot Management Control Physical Fabric Physical


Cluster m Slots Numberi Physical Port/ Port/Logical Port/Logical
Per ng in a Logical Interface Interface Interface
Node Cluster

SRX460 Node 0 1 0-6 fxp0 Dual (redundant) Dual (redundant)


0 MACsec-enabled MACsec-enabled
HA control ports HA fabric ports
Node 1 7-13 (10GbE) are (10GbE)
xe-0/0/0 and
Dual Fabric ports
xe-0/0/1
with macsec
It uses 1-Gigabit enabled are
Ethernet SFP as xe-0/0/2 and
control port. xe-0/0/3

Table 5: Chassis Cluster Interface Renumbering for SRX4600

Device Renumbering Constant Node 0 Interface Name Node 1 Interface Name

SRX4600 7 xe-1/0/0 xe-8/0/0

Table 6: Chassis Cluster Fabric Interface Details for SRX4600

Interfaces Used as Fabric Supports Z-Mode Supports MACsec?


Port? Traffic?

Dedicated fabric ports Yes Yes Yes

8X10-Gigabit Ethernet Interface SFPP Yes Yes No


ports

4X40-Gigabit Ethernet Interface QSFP28 Yes Yes No


ports

4x10-Gigabit Ethernet Interface SFPP Yes Yes No


ports
25

Table 6: Chassis Cluster Fabric Interface Details for SRX4600 (Continued)

Interfaces Used as Fabric Supports Z-Mode Supports MACsec?


Port? Traffic?

2X100-Gigabit Ethernet Interface QSFP28 No No No


slots

Mix and match of fabric ports are not supported. That is, you cannot use one 10-Gigabit Ethernet
interface and one 40-Gigabit Ethernet interface for fabric links configuration. Dedicated fabric link
supports only 10-Gigabit Ethernet Interface.

Figure 10 on page 25 shows the slot numbering for both of the SRX Series Firewalls that become node
0 and node 1 of the chassis cluster after the cluster is formed.

Figure 10: Slot Numbering in SRX4600 Chassis Cluster

Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming for SRX4100 and SRX4200 Devices

The SRX4100 and SRX4200 devices use two 1-Gigabit Ethernet/10-Gigabit Ethernet ports, labeled as
CTL and FAB as control port and fabric port respectively.

Supported fabric interface types for SRX4100 and SRX4200 devices are 10-Gigabit Ethernet (xe) (10-
Gigabit Ethernet Interface SFP+ slots).
26

SRX4100 and SRX4200 devices do not support direct attach copper (DAC) cables for chassis cluster
control.

Table 7 on page 26 shows the slot numbering, as well as the physical port and logical interface
numbering, for both of the SRX Series Firewalls that become node 0 and node 1 of the chassis cluster
after the cluster is formed

Table 7: Chassis Cluster Slot Numbering, and Physical Port and Logical Interface Naming for SRX4100
and SRX4200 Devices

Model Chassis Maximu Slot Management Control Physical Fabric Physical


Cluster m Slots Numberi Physical Port/ Port/Logical Port/Logical
Per ng in a Logical Interface Interface Interface
Node Cluster

SRX410 Node 0 1 0 fxp0 Dedicated control Dedicated fabric


0 port, em0 port, any Ethernet
port (for dual fabric-
link), fab0

Node 1 7 Dedicated fabric


port, and any
Ethernet port (for
dual fabric-link),
fab1

SRX420 Node 0 1 0 fxp0 Dedicated control Dedicated fabric


0 port,em0 port, and any
Ethernet port (for
dual fabric-link),
fab0

Node 1 7 Dedicated fabric


port, and any
Ethernet port (for
dual fabric-link),
fab1

Figure 11 on page 27 and Figure 12 on page 27 shows the slot numbering for both of the SRX Series
Firewalls that become node 0 and node 1 of the chassis cluster after the cluster is formed.
27

Figure 11: Slot Numbering in SRX4100 Chassis Cluster

Figure 12: Slot Numbering in SRX4200 Chassis Cluster

The node 1 renumbers its interfaces by adding the total number of system FPCs to the original FPC
number of the interface. For example, see Table 8 on page 27 for interface renumbering on the SRX
Series Firewalls (SRX4100 and SRX4200).

Table 8: Chassis Cluster Interface Renumbering for SRX4100 and SRX4200

Device Renumbering Constant Node 0 Interface Name Node 1 Interface Name

SRX4100 7 xe-0/0/0 xe-7/0/0

SRX4200 7 xe-0/0/1 xe-7/0/1

On SRX4100 and SRX4200 devices, when the system comes up as chassis cluster, the xe-0/0/8 and
xe-7/0/8 interfaces are automatically set as fabric interfaces links. You can set up another pair of fabric
interfaces using any pair of 10-Gigabit interfaces to serve as the fabric between nodes. Note that, the
automatically created fabric interfaces cannot be deleted. However, you can delete the second pair of
fabric interfaces (manually configured interfaces).

Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming for SRX5800, SRX5600, and SRX5400 Devices

For chassis clustering, all SRX Series Firewalls have a built-in management interface named fxp0. For
most SRX Series Firewalls, the fxp0 interface is a dedicated port.
28

For the SRX5000 line, control interfaces are configured on SPCs.

Table 9 on page 28 shows the slot numbering, as well as the physical port and logical interface
numbering, for both of the SRX Series Firewalls that become node 0 and node 1 of the chassis cluster
after the cluster is formed.

Table 9: Chassis Cluster Slot Numbering, and Physical Port and Logical Interface Naming for SRX5000
Line Devices

Model Chassis Maximu Slot Management Control Physical Fabric Physical


Cluster m Slots Numberi Physical Port/ Port/Logical Port/Logical
Per ng in a Logical Interface Interface Interface
Node Cluster

SRX580 Node 0 12 (FPC 0—11 Dedicated Gigabit Control port on an Any Ethernet port
0 slots) Ethernet port SPC

fxp0 em0 fab0

Node 1 12—23 Dedicated Gigabit Control port on an Any Ethernet port


Ethernet port SPC

fxp0 em0 fab1

SRX560 Node 0 6 (FPC 0—5 Dedicated Gigabit Control port on an Any Ethernet port
0 slots) Ethernet port SPC

fxp0 em0 fab0

Node 1 6—11 Dedicated Gigabit Control port on an Any Ethernet port


Ethernet port SPC

fxp0 em0 fab1

SRX540 Node 0 3 (FPC 0—2 Dedicated Gigabit Control port on an Any Ethernet port
0 slots) Ethernet port SPC

fxp0 em0 fab0


29

Table 9: Chassis Cluster Slot Numbering, and Physical Port and Logical Interface Naming for SRX5000
Line Devices (Continued)

Model Chassis Maximu Slot Management Control Physical Fabric Physical


Cluster m Slots Numberi Physical Port/ Port/Logical Port/Logical
Per ng in a Logical Interface Interface Interface
Node Cluster

Node 1 3—5 Dedicated Gigabit Control port on an Any Ethernet port


Ethernet port SPC

fxp0 em0 fab1

After you enable chassis clustering, the two chassis joined together cease to exist as individuals and now
represent a single system. As a single system, the cluster now has twice as many slots. (See Figure 13 on
page 29.)

Figure 13: Slot Numbering in SRX5800 Chassis Cluster


30

FPC Slot Numbering in SRX Series Firewall Cards

SRX5600 and SRX5800 devices have Flex I/O Cards (Flex IOCs) that have two slots to accept the
following port modules:

• SRX-IOC-4XGE-XFP 4-Port XFP

• SRX-IOC-16GE-TX 16-Port RJ-45

• SRX-IOC-16GE-SFP 16-Port SFP

You can use these port modules to add from 4 to 16 Ethernet ports to your SRX Series Firewall. Port
numbering for these modules is

slot/port module/port

where slot is the number of the slot in the device in which the Flex IOC is installed; port module is 0 for
the upper slot in the Flex IOC or 1 for the lower slot when the card is vertical, as in an SRX5800 device;
and port is the number of the port on the port module. When the card is horizontal, as in an SRX5400 or
SRX5600 device, port module is 0 for the left-hand slot or 1 for the right-hand slot.

SRX5400 devices support only SRX5K-MPC cards. The SRX5K-MPC cards also have two slots to accept
the following port modules:

• SRX-MIC-10XG-SFPP 10-port-SFP+ (xe)

• SRX-MIC-20GE-SFP 20-port SFP (ge)

• SRX-MIC-1X100G-CFP 1-port CFP (et)

• SRX-MIC-2X40G-QSFP 2-port QSFP (et)

See the hardware guide for your specific SRX Series model (SRX Series Services Gateways).

RELATED DOCUMENTATION

Example: Configure Chassis Clustering on SRX Series Firewalls | 130


31

Preparing Your Equipment for Chassis Cluster


Formation

To form a chassis cluster, a pair of the same kind of supported SRX Series Firewalls is combined to act as
a single system that enforces the same overall security. SRX Series Firewalls must meet the following
requirements to be included in a chassis clusters.

To form a chassis cluster, a pair of the same kind of supported SRX Series Firewalls is combined to act as
a single system that enforces the same overall security.

• The network node redundancy is achieved by grouping a pair of the same kind of supported SRX
Series Firewalls into a cluster.

• SRX Series Firewalls must be the same model.

• Junos OS requirements: Both the devices must be running the same Junos OS version

• Licensing requirements: Licenses are unique to each device and cannot be shared between the
devices. Both devices (which are going to form chassis cluster) must have the identical features and
license keys enabled or installed them. If both devices do not have an identical set of licenses, then
after a failover, that particular licensed feature might not work or the configuration might not
synchronize in chassis cluster formation.

• All services processing cards (SPCs), network processing cards (NPCs), and input/output cards (IOCs)
on applicable SRX Series Firewalls must have the same slot placement and must be of same type.
Example:

• For SRX5400, SRX5600 and SRX5800 chassis clusters, the placement and the type of services
processing cards (SPC, SPC2, SRX5K-SPC3), and input/output cards (IOC1, IOC2, IOC3, IOC4)
must match in two devices. Only SCB4 is not supported on SRX5400. All other components are
supported on SRX5400.

• For SRX3400 and SRX3600 chassis clusters, the placement and the type of SPCs, input/output
cards (IOCs, NPIOCs), and network processing cards (NPCs) must match in two devices.

You can use the show chassis hardware command to identify the type of the card.

Following example shows the placement and the type of cards used in a chassis cluster setup:

user@host> show chassis hardware


node0:
--------------------------------------------------------------------------
Hardware inventory:
32

Item Version Part number Serial number Description


Chassis JN1267B0FAGA SRX5800
Midplane REV 42 760-063937 ACRL3065 Enhanced SRX5800 Backplane
FPM Board REV 05 760-061272 CAHE4860 Front Panel Display
PDM Rev 01 740-063049 QCS2209509D Power Distribution Module
PEM 0 Rev 04 740-034724 QCS171002016 PS 4.1kW; 200-240V AC in
PEM 1 Rev 11 740-027760 QCS1825N07S PS 4.1kW; 200-240V AC in
Routing Engine 0 REV 01 750-095568 CALK8884 SRX5k RE-2000x6
Routing Engine 1 REV 01 750-095568 CADZ9076 SRX5k RE-2000x6
CB 0 REV 26 750-031391 CALV3002 SRX5k SCB4
CB 1 REV 26 750-031391 CALV3009 SRX5k SCB4
FPC 2 REV 28 750-073435 CALS4630 SPC3
CPU BUILTIN BUILTIN SRX5k vCPP Broadwell
PIC 0 BUILTIN BUILTIN SPU Cp-Flow
PIC 1 BUILTIN BUILTIN SPU Flow
FPC 3 REV 17 750-044175 CABE7777 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 4 REV 08 750-061262 CAFD8147 SRX5k IOC II
CPU REV 02 711-061263 CAFV7488 SRX5k MPC PMB
MIC 0 REV 03 750-055732 CAFV9369 20x 1GE(LAN) SFP
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 0 REV 02 740-011613 PNB1GJR SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) SFP
FPC 5 REV 10 750-062242 CAKX2328 SRX5k IOC3 2CGE+4XGE
PIC 0 BUILTIN BUILTIN 2x 10GE SFP+
Xcvr 0 REV 01 740-021308 ANA07RE SFP+-10G-SR
Xcvr 1 REV 01 740-031980 AQF0RBJ SFP+-10G-SR
PIC 1 BUILTIN BUILTIN 1x 100GE CFP2
PIC 2 BUILTIN BUILTIN 2x 10GE SFP+
Xcvr 0 REV 01 740-031980 AA1650304RF SFP+-10G-SR
Xcvr 1 REV 01 740-021308 AQ93BDK SFP+-10G-SR
PIC 3 BUILTIN BUILTIN 1x 100GE CFP2
FPC 8 REV 46 750-056519 CALC4514 SRX5k IOC4 MRATE
CPU REV 21 750-057177 CALC3494 SMPC PMB
PIC 0 BUILTIN BUILTIN MRATE-6xQSFPP-XGE-XLGE-CGE
Xcvr 0 REV 01 740-059437 000T20128 QSFP28-LPBK
Xcvr 1 REV 01 740-067443 1ACP13450KH QSFP+-40G-SR4
PIC 1 BUILTIN BUILTIN MRATE-6xQSFPP-XGE-XLGE-CGE
Xcvr 0 REV 01 740-059437 0000T3443 QSFP28-LPBK
33

Fan Tray 0 REV 06 740-035409 ACAE9390 Enhanced Fan Tray


Fan Tray 1 REV 06 740-035409 ACAE9386 Enhanced Fan Tray

node1:
--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1267B01AGA SRX5800
Midplane REV 42 760-063937 ACRL3068 Enhanced SRX5800 Backplane
FPM Board REV 05 760-061272 CAJX9988 Front Panel Display
PDM Rev 01 740-063049 QCS2209507A Power Distribution Module
PEM 0 Rev 11 740-027760 QCS1822N0EY PS 4.1kW; 200-240V AC in
PEM 1 Rev 03 740-034724 QCS17020203F PS 4.1kW; 200-240V AC in
Routing Engine 0 REV 01 750-095568 CALK8904 SRX5k RE-2000x6
Routing Engine 1 REV 01 750-095568 CADZ9076 SRX5k RE-2000x6
CB 0 REV 26 750-031391 CALV3010 SRX5k SCB4
CB 1 REV 26 750-031391 CALV3000 SRX5k SCB4
FPC 2 REV 28 750-073435 CAKZ9620 SPC3
CPU BUILTIN BUILTIN SRX5k vCPP Broadwell
PIC 0 BUILTIN BUILTIN SPU Cp-Flow
PIC 1 BUILTIN BUILTIN SPU Flow
FPC 3 REV 18 750-054877 CACH4082 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 4 REV 08 750-061262 CAFD8165 SRX5k IOC II
CPU REV 02 711-061263 CAFV7507 SRX5k MPC PMB
MIC 0 REV 03 750-055732 CAFV6603 20x 1GE(LAN) SFP
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 0 REV 01 740-011613 AM0805S8M4N SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) SFP
FPC 5 REV 03 750-062242 CAFZ2748 SRX5k IOC3 2CGE+4XGE
PIC 0 BUILTIN BUILTIN 2x 10GE SFP+
Xcvr 0 REV 01 740-021308 11T511100788 SFP+-10G-SR
Xcvr 1 REV 01 740-031980 AS92WJ0 SFP+-10G-SR
PIC 1 BUILTIN BUILTIN 1x 100GE CFP2
PIC 2 BUILTIN BUILTIN 2x 10GE SFP+
Xcvr 0 REV 01 740-031980 AA1650304EZ SFP+-10G-SR
Xcvr 1 REV 01 740-031980 ANS0EAR SFP+-10G-SR
PIC 3 BUILTIN BUILTIN 1x 100GE CFP2
FPC 8 REV 46 750-056519 CALC4526 SRX5k IOC4 MRATE
34

CPU REV 21 750-057177 CALF5727 SMPC PMB


PIC 0 BUILTIN BUILTIN MRATE-6xQSFPP-XGE-XLGE-CGE
Xcvr 1 REV 01 740-067443 1ACP13450L9 QSFP+-40G-SR4
PIC 1 BUILTIN BUILTIN MRATE-6xQSFPP-XGE-XLGE-CGE
Fan Tray 0 REV 06 740-035409 ACAE9298 Enhanced Fan Tray
Fan Tray 1 REV 06 740-035409 ACAE9314 Enhanced Fan Tray

• SRX1500—Has dedicated slots for each kind of card that cannot be interchanged.

• SRX4600—Has dedicated slots for each kind of card that cannot be interchanged.

• SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M—Although the devices must be of the
same type, they can contain different Physical Interface Modules (PIMs).

• The control ports on the respective nodes are connected to form a control plane that synchronizes
the configuration and kernel state to facilitate the high availability of interfaces and services.

• The data plane on the respective nodes is connected over the fabric ports to form a unified data
plane. The fabric link allows for the management of cross-node flow processing and for the
management of session redundancy.

RELATED DOCUMENTATION

Chassis Cluster Overview | 2


Understanding Chassis Cluster Fabric Interfaces | 55

Connecting SRX Series Firewalls to Create a Chassis


Cluster

An SRX Series chassis cluster is created by physically connecting two identical cluster-supported SRX
Series Firewalls together using a pair of the same type of Ethernet connections. The connection is made
for both a control link and a fabric (data) link between the two devices.

Control links in a chassis cluster are made using specific ports.

The interface value changes with the cluster offset value. Based on the cluster index, the interface is
named as type-fpc/pic/port. For example, ge-1/0/1 , where 1 is cluster index and the FPC number. You
must use the following ports to form the control link on the following SRX Series Firewalls:

• For SRX300 devices, connect the ge-0/0/1 on node 0 to the ge-1/0/1 on node 1.
35

• For SRX320 devices, connect the ge-0/0/1 on node 0 to the ge-3/0/1 on node 1.

• For SRX340, SRX345, and SRX380 devices, connect the ge-0/0/1 on node 0 to the ge-5/0/1 on
node 1.

• For SRX550M devices, connect the ge-0/0/1 on node 0 to the ge-9/0/1 on node 1.

• For SRX1500 devices, connect the HA control port on node 0 to the HA control port on node 1

To establish a fabric link:

• For SRX300 and SRX320 devices, connect any interface except ge-0/0/0 and ge-0/0/1.

• For SRX340, SRX345, and SRX380 devices, connect any interface except fxp0 and ge-0/0/1.

Figure 14 on page 35, Figure 15 on page 35, Figure 16 on page 36, Figure 17 on page 36, Figure 19
on page 36 and Figure 20 on page 37 show pairs of SRX Series Firewalls with the fabric links and
control links connected.

Figure 14: Connecting SRX300 Devices in a Chassis Cluster

Figure 15: Connecting SRX320 Devices in a Chassis Cluster


36

Figure 16: Connecting SRX340 Devices in a Chassis Cluster

Figure 17: Connecting SRX345 Devices in a Chassis Cluster

Figure 18: Connecting SRX380 Devices in a Chassis Cluster

Figure 19: Connecting SRX550M Devices in a Chassis Cluster


37

Figure 20: Connecting SRX1500 Devices in a Chassis Cluster

For SRX1500 devices, the connection that serves as the control link must be between the built-in
control ports on each device.

You can connect two control links (SRX4600, SRX5600, SRX5800, and SRX3000 lines only) and two
fabric links between the two devices in the cluster to reduce the chance of control link and fabric link
failure. See "Understanding Chassis Cluster Dual Control Links" on page 172 and "Understanding
Chassis Cluster Dual Fabric Links" on page 201.

Figure 21 on page 37, Figure 22 on page 38 and Figure 23 on page 38 show pairs of SRX Series
Firewalls with the fabric links and control links connected.

Figure 21: Connecting SRX4600 Devices in a Chassis Cluster


38

Figure 22: Connecting SRX4100 Devices in a Chassis Cluster

Figure 23: Connecting SRX4200 Devices in a Chassis Cluster

Figure 24 on page 39, Figure 25 on page 39, and Figure 26 on page 40 show pairs of SRX Series
Firewalls with the fabric links and control links connected.

Service Processing Cards (SPC) have two dedicated ports ( HA0 and HA1) for connecting the control
links in the chassis cluster.

Fabric ports are revenue ports available from any IOC card. Fabric links are connected to the same slot
and port on both SRX5000 line of devices.

SRX5000 line devices do not have built-in ports, so the control link for these gateways must be the
control ports on their SPCs with a slot numbering offset of 3 for SRX5400, offset of 6 for SRX5600
devices and 12 for SRX5800 devices.

Figure 24 on page 39 shows pair of SRX5800 devices having single SPC card each connected with a
control link. The fabric link is connected using the IOC card. For dual control links, two SPC3 cards are
required for connection.
39

Figure 24: Connecting SRX5800 Devices in a Chassis Cluster

Figure 25 on page 39 shows dual control links connected using two SPC3 cards and dual fabric links
using IOC cards.

Figure 25: Connecting SRX5600 Devices in a Chassis Cluster

When you connect a single control link on SRX5000 line devices, the control link ports are a one-to-one
mapping with the Routing Engine slot. If your Routing Engine is in slot 0, you must use control port 0 to
link the Routing Engines.
40

When a SPC is the control plane as well as hosting the control port, this creates a single point of failure.
If the SPC goes down on the primary node, the node is automatically rebooted to avoid split brain.

Figure 26: Connecting SRX5400 Devices in a Chassis Cluster

Dual control links are not supported on an SRX5400 device due to the limited number of slots.

RELATED DOCUMENTATION

SRX Series Chassis Cluster Configuration Overview | 13


Example: Setting the Node ID and Cluster ID for Security Devices in a Chassis Cluster | 40
Example: Configuring the Chassis Cluster Management Interface | 46
Example: Configuring the Number of Redundant Ethernet Interfaces in a Chassis Cluster

Example: Setting the Node ID and Cluster ID for


Security Devices in a Chassis Cluster

IN THIS SECTION

Requirements | 41

Overview | 42
41

Configuration | 42

Verification | 43

When a device joins a cluster, it becomes a node of that cluster. With the exception of unique node
settings and management IP addresses, nodes in a cluster share the same configuration.

• A cluster is identified by a cluster ID (cluster-id) specified as a number from 1 through 255. Setting a
cluster ID to 0 is equivalent to disabling a cluster. A cluster ID greater than 15 can only be set when
the fabric and control link interfaces are connected back-to-back or connected on separate VLANs.

To use extended cluster IDs without back-to-back connectivity, control and fabric link traffic for each
SRX cluster must be separated using unique VLAN IDs.

Example: Extended Cluster ID

The following message is displayed when you try to set a cluster ID greater than 15, and when fabric
and control link interfaces are not connected back-to-back or are not connected on separate VLANs:

{primary:node1}
user@host> set chassis cluster cluster-id 254 node 1 reboot
For cluster-ids greater than 15 and when deploying more than one cluster in a single Layer 2
BROADCAST domain, it is mandatory that fabric and control links are either connected back-to-
back or are connected on separate private VLANS.

• A cluster node is identified by a node ID (node) specified as a number from 0 through 1.

This example shows how to set the chassis cluster node ID and chassis cluster ID , which you must
configure after connecting two devices together. A chassis cluster ID identifies the cluster to which the
devices belong, and a chassis cluster node ID identifies a unique node within the cluster. After wiring the
two devices together, you use CLI operational mode commands to enable chassis clustering by assigning
a cluster ID and node ID on each chassis in the cluster. The cluster ID is the same on both nodes.

Requirements

Before you begin, ensure that you can connect to each device through the console port.

Ensure that the devices are running the same version of the Junos operating system (Junos OS) and the
security devices are of same model.
42

The factory-default configuration of an SRX Series Firewall includes the configuration of the interfaces
on the device. Therefore, before enabling chassis clustering on the device, you must remove any existing
configuration associated with those interfaces that will be transformed into the control and fabric
interfaces. See "Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical
Interface Naming" on page 18 for more information.

Overview

The system uses the chassis cluster ID and chassis cluster node ID to apply the correct configuration for
each node (for example, when you use the apply-groups command to configure the chassis cluster
management interface). The chassis cluster ID and node ID statements are written to the EPROM, and
the statements take effect when the system is rebooted.

In this example, you configure a chassis cluster ID of 1. You also configure a chassis cluster node ID of 0
for the first node, which allows redundancy groups to be primary on this node when priority settings for
both nodes are the same, and a chassis cluster node ID of 1 for the other node.

Chassis cluster supports automatic synchronization of configurations. When a secondary node joins a
primary node and a chassis cluster is formed, the primary node configuration is automatically copied and
applied to the secondary node. See "Understanding Automatic Chassis Cluster Synchronization Between
Primary and Secondary Nodes" on page 151.

Configuration

IN THIS SECTION

Procedure | 42

Procedure

Step-by-Step Procedure

To specify the chassis cluster node ID and cluster ID, you need to set two devices to cluster mode and
reboot the devices. You must enter the following operational mode commands on both devices:
43

1. Connect to the first device through the console port.

user@host> set chassis cluster cluster-id 1 node 0 reboot


Successfully enabled chassis cluster. Going to reboot now.

2. Connect to the second device through the console port.

user@host> set chassis cluster cluster-id 1 node 1 reboot


Successfully enabled chassis cluster. Going to reboot now.

For SRX5400, SRX5600 and SRX5800 devices, you must configure the control ports before the
cluster is formed.

To do this, you connect to the console port on the primary device, give it a node ID, and identify the
cluster it will belong to, and then reboot the system. You then connect the console port to the other
device, give it a node ID, and assign it the same cluster ID you gave to the first node, and then reboot
the system. In both instances, you can cause the system to boot automatically by including the reboot
parameter in the CLI command line. (For further explanation of primary and secondary nodes, see
"Understanding Chassis Cluster Redundancy Groups" on page 91.)

Verification

IN THIS SECTION

Verifying Chassis Cluster Status | 43

Verifying Chassis Cluster Status

Purpose

Verify the status of a chassis cluster.


44

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}[edit]
user@host> show chassis cluster status

Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 100 primary no no
node1 1 secondary no no

Redundancy group: 1 , Failover count: 1


node0 0 primary no no
node1 0 secondary no no

Meaning

The sample output shows that devices in the chassis cluster are communicating properly, with one
device functioning as the primary node and the other as the secondary node.

RELATED DOCUMENTATION

SRX Series Chassis Cluster Configuration Overview | 13


Example: Configuring the Chassis Cluster Management Interface | 46
Example: Configuring the Number of Redundant Ethernet Interfaces in a Chassis Cluster

Chassis Cluster Management Interfaces

IN THIS SECTION

Understanding Management Interface on an Active Chassis Cluster | 45


45

Example: Configuring the Chassis Cluster Management Interface | 46

On SRX Series Firewalls in a chassis cluster, management interfaces allow out-of-band network access
and network management to each node in the cluster. For more information, see the following topics:

Understanding Management Interface on an Active Chassis Cluster

Most of SRX Series Firewalls contain an fxp0 interface. The fxp0 interfaces function like standard
management interfaces on SRX Series Firewalls and allow network access to each node in the cluster.

Management interfaces are the primary interfaces for accessing the device remotely. Typically, a
management interface is not connected to the in-band network, but is connected instead to the device's
internal network. Through a management interface you can access the device over the network using
utilities such as ssh and telnet and configure the device from anywhere, regardless of its physical
location. SNMP can use the management interface to gather statistics from the device. A management
interface enables authorized users and management systems connect to the device over the network.

Some SRX Series Firewalls have a dedicated management port on the front panel. For other types of
platforms, you can configure a management interface on one of the network interfaces. This interface
can be dedicated to management or shared with other traffic. Before users can access the management
interface, you must configure it. Information required to set up the management interface includes its IP
address and prefix. In many types of Junos OS devices (or recommended configurations), it is not
possible to route traffic between the management interface and the other ports. Therefore, you must
select an IP address in a separate (logical) network, with a separate prefix (netmask).

For most SRX Series chassis clusters, the fxp0 interface is a dedicated port. SRX340 and SRX345
devices contain an fxp0 interface. SRX300 and SRX320 devices do not have a dedicated port for fxp0.
The fxp0 interface is repurposed from a built-in interface. The fxp0 interface is created when the system
reboots the devices after you designate one node as the primary device and the other as the secondary
device.

We recommend giving each node in a chassis cluster a unique IP address for the fxp0 interface of each
node. This practice allows independent node management.
46

Example: Configuring the Chassis Cluster Management Interface

IN THIS SECTION

Requirements | 46

Overview | 46

Configuration | 47

Verification | 53

This example shows how to provide network management access to a chassis cluster.

Requirements
Before you begin, set the chassis cluster node ID and cluster ID. See "Example: Setting the Chassis
Cluster Node ID and Cluster ID" on page 40.

Overview
You must assign a unique IP address to each node in the cluster to provide network management access.
This configuration is not replicated across the two nodes.

If you try to access the nodes in a cluster over the network before you configure the fxp0 interface, you
will lose access to the cluster.

In this example, you configure the following information for IPv4:

• Node 0 name—node0-router

• IP address assigned to node 0—10.1.1.1/24

• Node 1 name—node1-router

• IP address assigned to node 1—10.1.1.2/24

In this example, you configure the following information for IPv6:

• Node 0 name—node0-router

• IP address assigned to node 0—2001:db8:1::2/32

• Node 1 name—node1-router

• IP address assigned to node 1—2001:db8:1::3/32


47

Configuration

IN THIS SECTION

Configuring the Chassis Cluster Management Interface with IPv4 Addresses | 47

Verifying the Chassis Cluster Management Interface Configuration (IPv4 Addresses) | 49

Configuring the Chassis Cluster Management Interface with IPv6 Addresses | 50

Configuring the Chassis Cluster Management Interface with IPv4 Addresses

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

To configure a chassis cluster management interface for IPv4:

{primary:node0}[edit]
user@host#
set groups node0 system host-name node0-router
set groups node0 interfaces fxp0 unit 0 family inet address 10.1.1.1/24
set groups node1 system host-name node1-router
set groups node1 interfaces fxp0 unit 0 family inet address 10.1.1.2/24
set apply-groups “${node}”

Step-by-Step Procedure

To configure a chassis cluster management interface for IPv4:

1. Configure the name of node 0 and assign an IP address.

{primary:node0}[edit]
user@host# set groups node0 system host-name node0-router
user@host# set groups node0 interfaces fxp0 unit 0 family inet address 10.1.1.1/24
48

2. Configure the name of node 1 and assign an IP address.

{primary:node0}[edit]
user@host# set groups node1 system host-name node1-router
user@host# set groups node1 interfaces fxp0 unit 0 family inet address 10.1.1.2/24

3. Apply the groups configuration to the nodes.

{primary:node0}[edit]
user@host# set apply-groups “${node}”

4. If you are done configuring the device, commit the configuration.

{primary:node0}[edit]
user@host# commit

Results

From configuration mode, confirm your configuration by entering the show groups and show apply-groups
commands. If the output does not display the intended configuration, repeat the configuration
instructions in this example to correct it.

{primary:node0}[edit]
user@host# show groups
node0 {
system {
host-name node0-router;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 10.1.1.1/24;
}
}
}
}
}
node1 {
49

system {
host-name node1-router;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 10.1.1.2/24;
}
}
}
}
}

{primary:node0}[edit]
user@host# show apply-groups
## Last changed: 2010-09-16 11:08:29 UTC
apply-groups "${node}";

If you are done configuring the device, enter commit from configuration mode.

Verifying the Chassis Cluster Management Interface Configuration (IPv4 Addresses)

Purpose

Verify the chassis cluster management interface configuration.

Action

To verify the configuration is working properly, enter the show interfaces terse, show configuration groups
node node0 interfaces and show configuration groups node node1 interfaces commands.

{primary:node0} [edit]
user@host> show interfaces terse | match fxp0
50

fxp0 up up
fxp0.0 up up inet 10.1.1.1/24

{primary:node0} [edit]
user@host> show configuration groups node0 interfaces

fxp0 {
unit 0 {
family inet {
address 10.1.1.1/24;
}
}
}

{primary:node0} [edit]
user@host> show configuration groups node1 interfaces

fxp0 {
unit 0 {
family inet {
address 10.1.1.2/24;
}
}
}

Meaning

The output displays the management interface information with their status.

Configuring the Chassis Cluster Management Interface with IPv6 Addresses

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.
51

To configure a chassis cluster management interface for IPv6:

{primary:node0}[edit]
user@host#
set groups node0 system host-name node0-router
set groups node0 interfaces fxp0 unit 0 family inet6 address 2001:db8:1::2/32
set groups node1 system host-name node1-router
set groups node1 interfaces fxp0 unit 0 family inet6 address 2001:db8:1::3/32

Step-by-Step Procedure

To configure a chassis cluster management interface for IPv6:

1. Configure the name of node 0 and assign an IP address.

{primary:node0}[edit]
user@host# set groups node0 system host-name node0-router
user@host# set groups node0 interfaces fxp0 unit 0 family inet6 address 2001:db8:1::2/32

2. Configure the name of node 1 and assign an IP address.

{primary:node0}[edit]
user@host# set groups node1 system host-name node1-router
user@host# set groups node1 interfaces fxp0 unit 0 family inet6 address 2001:db8:1::3/32

3. If you are done configuring the device, commit the configuration.

{primary:node0}[edit]
user@host# commit
52

Results

From configuration mode, confirm your configuration by entering the show groups and show apply-groups
commands. If the output does not display the intended configuration, repeat the configuration
instructions in this example to correct it.

{primary:node0}[edit]
user@host# show groups
node0 {
system {
host-name node0-router;
}
interfaces {
fxp0 {
unit 0 {
family inet6 {
address 2001:db8:1::2/32;
}
}
}
}
}
node1 {
system {
host-name node1-router;
}
interfaces {
fxp0 {
unit 0 {
family inet6 {
address 2001:db8:1::3/32;
}
}
}
}
}

{primary:node0}[edit]
user@host# show apply-groups
53

## Last changed: 2010-09-16 11:08:29 UTC


apply-groups "${node}";

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying the Chassis Cluster Management Interface Configuration (IPV6 Addresses) | 53

Verifying the Chassis Cluster Management Interface Configuration (IPV6 Addresses)

Purpose

Verify the chassis cluster management interface configuration.

Action

To verify the configuration is working properly, enter the show interfaces terse and show configuration groups
node0 interfaces commands.

{primary:node0} [edit]
user@host> show interfaces terse | match fxp0

fxp0 up up
fxp0.0 up up inet 2001:db8:1::2/32

{primary:node0} [edit]
user@host> show configuration groups node0 interfaces

fxp0 {
unit 0 {
family inet {
address 2001:db8:1::2/32;
}
54

}
}

{primary:node0} [edit]
user@host> show configuration groups node1 interfaces

fxp0 {
unit 0 {
family inet {
address 2001:db8:1::3/32;
}
}
}

Meaning

The output displays the management interface information with their status.

SEE ALSO

Example: Configure Chassis Clustering on SRX Series Firewalls | 130

RELATED DOCUMENTATION

Chassis Cluster Fabric Interfaces | 54


Chassis Cluster Control Plane Interfaces | 67

Chassis Cluster Fabric Interfaces

IN THIS SECTION

Understanding Chassis Cluster Fabric Interfaces | 55

Example: Configuring the Chassis Cluster Fabric Interfaces | 60


55

Verifying Chassis Cluster Data Plane Interfaces | 64

Viewing Chassis Cluster Data Plane Statistics | 64

Clearing Chassis Cluster Data Plane Statistics | 65

SRX Series devices in a chassis cluster use the fabric (fab) interface for session synchronization and
forward traffic between the two chassis. The fabric link is a physical connection between two Ethernet
interfaces on the same LAN. Both interfaces must be the same media type. For more information, see
the following topics:

Understanding Chassis Cluster Fabric Interfaces

IN THIS SECTION

Supported Fabric Interface Types for SRX Series Firewalls (SRX300 Series, SRX550M, SRX1500,
SRX4100/SRX4200, SRX4600, and SRX5000 line) | 56

Jumbo Frame Support | 57

Understanding Fabric Interfaces on SRX5000 Line Devices for IOC2 and IOC3 | 57

Understanding Session RTOs | 58

Understanding Data Forwarding | 59

Understanding Fabric Data Link Failure and Recovery | 59

The fabric is a physical connection between two nodes of a cluster and is formed by connecting a pair of
Ethernet interfaces back-to-back (one from each node).

Unlike for the control link, whose interfaces are determined by the system, you specify the physical
interfaces to be used for the fabric data link in the configuration.

The fabric is the data link between the nodes and is used to forward traffic between the chassis. Traffic
arriving on a node that needs to be processed on the other is forwarded over the fabric data link.
Similarly, traffic processed on a node that needs to exit through an interface on the other node is
forwarded over the fabric.
56

The data link is referred to as the fabric interface. It is used by the cluster's Packet Forwarding Engines
to transmit transit traffic and to synchronize the data plane software’s dynamic runtime state. The fabric
provides for synchronization of session state objects created by operations such as authentication,
Network Address Translation (NAT), Application Layer Gateways (ALGs), and IP Security (IPsec) sessions.

When the system creates the fabric interface, the software assigns it an internally derived IP address to
be used for packet transmission.

CAUTION: After fabric interfaces have been configured on a chassis cluster, removing
the fabric configuration on either node will cause the redundancy group 0 (RG0)
secondary node to move to a disabled state. (Resetting a device to the factory default
configuration removes the fabric configuration and thereby causes the RG0 secondary
node to move to a disabled state.) After the fabric configuration is committed, do not
reset either device to the factory default configuration.

Supported Fabric Interface Types for SRX Series Firewalls (SRX300 Series, SRX550M,
SRX1500, SRX4100/SRX4200, SRX4600, and SRX5000 line)

For SRX Series chassis clusters, the fabric link can be any pair of Ethernet interfaces spanning the
cluster; the fabric link can be any pair of Gigabit Ethernet interface. Examples:

• For SRX300, SRX320, SRX340, SRX550M, and SRX345 devices, the fabric link can be any pair of
Gigabit Ethernet interfaces. For SRX380 devices, the fabric link can be any pair of Gigabit Ethernet
interfaces or any pair of 10-Gigabit Ethernet interface.

• For SRX Series chassis clusters made up of SRX550M devices, SFP interfaces on Mini-PIMs cannot
be used as the fabric link.

• For SRX1500, the fabric link can be any pair of Ethernet interfaces spanning the cluster; the fabric
link can be any pair of Gigabit Ethernet interface or any pair of 10-Gigabit Ethernet interface.

• Supported fabric interface types for SRX4100 and SRX4200 devices are 10-Gigabit Ethernet (xe) (10-
Gigabit Ethernet Interface SFP+ slots).

• Supported fabric interface types for SRX4600 devices are 40-Gigabit Ethernet (et) (40-Gigabit
Ethernet Interface QSFP slots) and 10-Gigabit Ethernet (xe).

• Supported fabric interface types supported for SRX5000 line devices are:

• Fast Ethernet

• Gigabit Ethernet

• 10-Gigabit Ethernet
57

• 40-Gigabit Ethernet

• 100-Gigabit Ethernet

Starting in Junos OS Release 12.1X46-D10 and Junos OS Release 17.3R1, 100-Gigabit Ethernet
interface is supported on SRX5000 line devices.

Starting in Junos OS Release 19.3R1, the SRX5K-IOC4-10G and SRX5K-IOC4-MRAT are


supported along with SRX5K-SPC3 on the SRX5000 line devices. SRX5K-IOC4-10G MPIC
supports MACsec.

For details about port and interface usage for management, control, and fabric links, see "Understanding
SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming" on page 18.

Jumbo Frame Support

The fabric data link does not support fragmentation. To accommodate this state, jumbo frame support is
enabled by default on the link with an maximum transmission unit (MTU) size of 9014 bytes (9000 bytes
of payload + 14 bytes for the Ethernet header) on SRX Series Firewalls. To ensure the traffic that transits
the data link does not exceed this size, we recommend that no other interfaces exceed the fabric data
link's MTU size.

Understanding Fabric Interfaces on SRX5000 Line Devices for IOC2 and IOC3

Starting with Junos OS Release 15.1X49-D10, the SRX5K-MPC3-100G10G (IOC3) and the SRX5K-
MPC3-40G10G (IOC3) are introduced.

The SRX5K-MPC (IOC2) is a Modular Port Concentrator (MPC) that is supported on the SRX5400,
SRX5600, and SRX5800. This interface card accepts Modular Interface Cards (MICs), which add
Ethernet ports to your services gateway to provide the physical connections to various network media
types. The MPCs and MICs support fabric links for chassis clusters. The SRX5K-MPC provides 10-
Gigabit Ethernet (with 10x10GE MIC), 40-Gigabit Ethernet, 100-Gigabit Ethernet, and 20x1GE Ethernet
ports as fabric ports. On SRX5400 devices, only SRX5K-MPCs (IOC2) are supported.

The SRX5K-MPC3-100G10G (IOC3) and the SRX5K-MPC3-40G10G (IOC3) are Modular Port
Concentrators (MPCs) that are supported on the SRX5400, SRX5600, and SRX5800. These interface
cards accept Modular Interface Cards (MICs), which add Ethernet ports to your services gateway to
provide the physical connections to various network media types. The MPCs and MICs support fabric
links for chassis clusters.

The two types of IOC3 Modular Port Concentrators (MPCs), which have different built-in MICs, are the
24x10GE + 6x40GE MPC and the 2x100GE + 4x10GE MPC.

Due to power and thermal constraints, all four PICs on the 24x10GE + 6x40GE cannot be powered on.
A maximum of two PICs can be powered on at the same time.
58

Use the set chassis fpc <slot> pic <pic> power off command to choose the PICs you want to power on.

On SRX5400, SRX5600, and SRX5800 devices in a chassis cluster, when the PICs containing fabric links
on the SRX5K-MPC3-40G10G (IOC3) are powered off to turn on alternate PICs, always ensure that:

• The new fabric links are configured on the new PICs that are turned on. At least one fabric link must
be present and online to ensure minimal RTO loss.

• The chassis cluster is in active-passive mode to ensure minimal RTO loss, once alternate links are
brought online.

• If no alternate fabric links are configured on the PICs that are turned on, RTO synchronous
communication between the two nodes stops and the chassis cluster session state will not back up,
because the fabric link is missing. You can view the CLI output for this scenario indicating a bad
chassis cluster state by using the show chassis cluster interfaces command.

Understanding Session RTOs

The data plane software, which operates in active/active mode, manages flow processing and session
state redundancy and processes transit traffic. All packets belonging to a particular session are
processed on the same node to ensure that the same security treatment is applied to them. The system
identifies the node on which a session is active and forwards its packets to that node for processing.
(After a packet is processed, the Packet Forwarding Engine transmits the packet to the node on which its
egress interface exists if that node is not the local one.)

To provide for session (or flow) redundancy, the data plane software synchronizes its state by sending
special payload packets called runtime objects (RTOs) from one node to the other across the fabric data
link. By transmitting information about a session between the nodes, RTOs ensure the consistency and
stability of sessions if a failover were to occur, and thus they enable the system to continue to process
traffic belonging to existing sessions. To ensure that session information is always synchronized between
the two nodes, the data plane software gives RTOs transmission priority over transit traffic.

The data plane software creates RTOs for UDP and TCP sessions and tracks state changes. It also
synchronizes traffic for IPv4 pass-through protocols such as Generic Routing Encapsulation (GRE) and
IPsec.

RTOs for synchronizing a session include:

• Session creation RTOs on the first packet

• Session deletion and age-out RTOs

• Change-related RTOs, including:

• TCP state changes

• Timeout synchronization request and response messages


59

• RTOs for creating and deleting temporary openings in the firewall (pinholes) and child session
pinholes

Understanding Data Forwarding

For Junos OS, flow processing occurs on a single node on which the session for that flow was
established and is active. This approach ensures that the same security measures are applied to all
packets belonging to a session.

A chassis cluster can receive traffic on an interface on one node and send it out to an interface on the
other node. (In active/active mode, the ingress interface for traffic might exist on one node and its
egress interface on the other.)

This traversal is required in the following situations:

• When packets are processed on one node, but need to be forwarded out an egress interface on the
other node

• When packets arrive on an interface on one node, but must be processed on the other node

If the ingress and egress interfaces for a packet are on one node, but the packet must be processed
on the other node because its session was established there, it must traverse the data link twice. This
can be the case for some complex media sessions, such as voice-over-IP (VoIP) sessions.

Understanding Fabric Data Link Failure and Recovery

Intrusion Detection and Prevention (IDP) services do not support failover. For this reason, IDP services
are not applied for sessions that were present prior to the failover. IDP services are applied for new
sessions created on the new primary node.

The fabric data link is vital to the chassis cluster. If the link is unavailable, traffic forwarding and RTO
synchronization are affected, which can result in loss of traffic and unpredictable system behavior.

To eliminate this possibility, Junos OS uses fabric monitoring to check whether the fabric link, or the two
fabric links in the case of a dual fabric link configuration, are alive by periodically transmitting probes
over the fabric links. If Junos OS detects fabric faults, RG1+ status of the secondary node changes to
ineligible. It determines that a fabric fault has occurred if a fabric probe is not received but the fabric
interface is active. To recover from this state, both the fabric links need to come back to online state and
should start exchanging probes. As soon as this happens, all the FPCs on the previously ineligible node
will be reset. They then come to online state and rejoin the cluster.

If you make any changes to the configuration while the secondary node is disabled, execute the commit
command to synchronize the configuration after you reboot the node. If you did not make configuration
changes, the configuration file remains synchronized with that of the primary node.
60

Starting with Junos OS Release 12.1X47-D10 and Junos OS Release 17.3R1, the fabric monitoring
feature is enabled by default on SRX5800, SRX5600, and SRX5400 devices.

Starting with Junos OS Release 12.1X47-D10 and Junos OS Release 17.3R1, recovery of the fabric link
and synchronization take place automatically.

When both the primary and secondary nodes are healthy (that is, there are no failures) and the fabric
link goes down, RG1+ redundancy group(s) on the secondary node becomes ineligible. When one of the
nodes is unhealthy (that is, there is a failure), RG1+ redundancy group(s) on this node (either the primary
or secondary node) becomes ineligible. When both nodes are unhealthy and the fabric link goes down,
RG1+ redundancy group(s) on the secondary node becomes ineligible. When the fabric link comes up,
the node on which RG1+ became ineligible performs a cold synchronization on all Services Processing
Units and transitions to active standby.

• If RG0 is primary on an unhealthy node, then RG0 will fail over from an unhealthy to a healthy node.
For example, if node 0 is primary for RG0+ and node 0 becomes unhealthy, then RG1+ on node 0 will
transition to ineligible after 66 seconds of a fabric link failure and RG0+ fails over to node 1, which is
the healthy node.

• Only RG1+ transitions to an ineligible state. RG0 continues to be in either a primary or secondary
state.

Use the show chassis cluster interfaces CLI command to verify the status of the fabric link.

SEE ALSO

Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming | 18
Understanding Chassis Cluster Dual Fabric Links | 201

Example: Configuring the Chassis Cluster Fabric Interfaces

IN THIS SECTION

Requirements | 61

Overview | 61

Configuration | 61

Verification | 63
61

This example shows how to configure the chassis cluster fabric. The fabric is the back-to-back data
connection between the nodes in a cluster. Traffic on one node that needs to be processed on the other
node or to exit through an interface on the other node passes over the fabric. Session state information
also passes over the fabric.

Requirements
Before you begin, set the chassis cluster ID and chassis cluster node ID. See "Example: Setting the Node
ID and Cluster ID for Security Devices in a Chassis Cluster " on page 40.

Overview
In most SRX Series Firewalls in a chassis cluster, you can configure any pair of Gigabit Ethernet
interfaces or any pair of 10-Gigabit interfaces to serve as the fabric between nodes.

You cannot configure filters, policies, or services on the fabric interface. Fragmentation is not supported
on the fabric link. The maximum MTU size for fabric interfaces is 9014 bytes and the maximum MTU
size for other interfaces is 8900 bytes. Jumbo frame support on the member links is enabled by default.

This example illustrates how to configure the fabric link.

Only the same type of interfaces can be configured as fabric children, and you must configure an equal
number of child links for fab0 and fab1.

If you are connecting each of the fabric links through a switch, you must enable the jumbo frame feature
on the corresponding switch ports. If both of the fabric links are connected through the same switch, the
RTO-and-probes pair must be in one virtual LAN (VLAN) and the data pair must be in another VLAN.
Here too, the jumbo frame feature must be enabled on the corresponding switch ports.

Configuration

IN THIS SECTION

Procedure | 62
62

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set interfaces fab0 fabric-options member-interfaces ge-0/0/1
set interfaces fab1 fabric-options member-interfaces ge-7/0/1

Step-by-Step Procedure

To configure the chassis cluster fabric:

• Specify the fabric interfaces.

{primary:node0}[edit]
user@host# set interfaces fab0 fabric-options member-interfaces ge-0/0/1
{primary:node0}[edit]
user@host# set interfaces fab1 fabric-options member-interfaces ge-7/0/1

Results

From configuration mode, confirm your configuration by entering the show interfaces command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

{primary:node0}[edit]
user@host# show interfaces
...
fab0 {
fabric-options {
member-interfaces {
ge-0/0/1;
}
63

}
}
fab1 {
fabric-options {
member-interfaces {
ge-7/0/1;
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying the Chassis Cluster Fabric | 63

Verifying the Chassis Cluster Fabric

Purpose

Verify the chassis cluster fabric.

Action

From operational mode, enter the show interfaces terse | match fab command.

{primary:node0}
user@host> show interfaces terse | match fab
ge-0/0/1.0 up up aenet --> fab0.0
ge-7/0/1.0 up up aenet --> fab1.0
fab0 up up
fab0.0 up up inet 30.17.0.200/24
fab1 up up
fab1.0 up up inet 30.18.0.200/24
64

Verifying Chassis Cluster Data Plane Interfaces

IN THIS SECTION

Purpose | 64

Action | 64

Purpose

Display chassis cluster data plane interface status.

Action

From the CLI, enter the show chassis cluster data-plane interfaces command:

{primary:node1}
user@host> show chassis cluster data-plane interfaces
fab0:
Name Status
ge-2/1/9 up
ge-2/2/5 up
fab1:
Name Status
ge-8/1/9 up
ge-8/2/5 up

Viewing Chassis Cluster Data Plane Statistics

IN THIS SECTION

Purpose | 65

Action | 65
65

Purpose

Display chassis cluster data plane statistics.

Action

From the CLI, enter the show chassis cluster data-plane statistics command:

{primary:node1}
user@host> show chassis cluster data-plane statistics

Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
Session create 0 0
Session close 0 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RTSP ALG 0 0

Clearing Chassis Cluster Data Plane Statistics

To clear displayed chassis cluster data plane statistics, enter the clear chassis cluster data-plane statistics
command from the CLI:

{primary:node1}
user@host> clear chassis cluster data-plane statistics
66

Cleared data-plane statistics

SEE ALSO

Configuring Chassis Clustering on SRX Series Devices | 129

Release History Table

Release Description

19.3R1 Starting in Junos OS Release 19.3R1, the SRX5K-IOC4-10G and SRX5K-IOC4-MRAT are
supported along with SRX5K-SPC3 on the SRX5000 line devices. SRX5K-IOC4-10G MPIC
supports MACsec.

15.1X49-D10 Starting with Junos OS Release 15.1X49-D10, the SRX5K-MPC3-100G10G (IOC3) and the
SRX5K-MPC3-40G10G (IOC3) are introduced.

12.1X47 Starting with Junos OS Release 12.1X47-D10 and Junos OS Release 17.3R1, the fabric monitoring
feature is enabled by default on SRX5800, SRX5600, and SRX5400 devices.

12.1X47 Starting with Junos OS Release 12.1X47-D10 and Junos OS Release 17.3R1, recovery of the fabric
link and synchronization take place automatically.

12.1X46 Starting in Junos OS Release 12.1X46-D10 and Junos OS Release 17.3R1, 100-Gigabit Ethernet
interface is supported on SRX5000 line devices.

RELATED DOCUMENTATION

SRX Series Chassis Cluster Configuration Overview | 13


Example: Configure Chassis Clustering on SRX Series Firewalls | 130
67

Chassis Cluster Control Plane Interfaces

IN THIS SECTION

Chassis Cluster Control Plane and Control Links | 67

Example: Configure Chassis Cluster Control Ports for Control Link | 71

Clear Chassis Cluster Control Plane Statistics | 76

SCB Chassis Cluster Control Links | 76

Change from Chassis Cluster to Standalone Mode | 77

Example: Configure Control Ports Using the SCB Control Link | 78

Transition from SPC to SCB with a Single Control Link | 82

Transition from SCB to SPC with a Single Control Link | 86

You can use control plane interfaces to synchronize the kernel state between Routing Engines on SRX
Series Firewalls in a chassis cluster. Control plane interfaces provide the link between the two nodes in
the cluster.

Control planes use this link to:

• Communicate node discovery.

• Maintains session state for a cluster.

• Access the configuration file.

• Detect liveliness signals across the nodes.

Chassis Cluster Control Plane and Control Links

IN THIS SECTION

Chassis Cluster Control Links | 68


68

The control plane software, which operates in active or backup mode, is an integral part of Junos OS
that is active on the primary node of a cluster. It achieves redundancy by communicating state,
configuration, and other information to the inactive Routing Engine on the secondary node. If the
primary Routing Engine fails, the secondary Routing Engine is ready to assume control.

The control plane software:

• Runs on the Routing Engine.

• Oversees the entire chassis cluster system, including interfaces on both nodes.

• Manages system and data plane resources, including the Packet Forwarding Engine (PFE) on each
node.

• Synchronizes the configuration over the control link.

• Establishes and maintains sessions, including authentication, authorization, and accounting (AAA)
functions.

• Manages application-specific signaling protocols.

• Establishes and maintains management sessions, such as Telnet connections.

• Handles asymmetric routing.

• Manages routing state, Address Resolution Protocol (ARP) processing, and Dynamic Host
Configuration Protocol (DHCP) processing.

Information from the control plane software follows two paths:

• On the primary node (where the Routing Engine is active), control information flows from the
Routing Engine to the local Packet Forwarding Engine.

• Control information flows across the control link to the secondary node's Routing Engine and Packet
Forwarding Engine.

The control plane software running on the primary Routing Engine maintains state for the entire cluster.
Only those processes running on the same node as the control plane software can update state
information. The primary Routing Engine synchronizes state for the secondary node and also processes
all host traffic.

Chassis Cluster Control Links

The control interfaces provide the control link between the two nodes in the cluster and are used for
routing updates and for control plane signal traffic, such as heartbeat and threshold information that
triggers node failover. The control link also synchronizes the configuration between the nodes. When
69

you submit configuration statements to the cluster, the control link synchronizes the configuration
automatically.

The control link relies on a proprietary protocol to transmit session state, configuration, and liveliness
state across the nodes.

Starting in Junos OS Release 19.3R1, the SRX5K-RE3-128G device is supported along with the SRX5K-
SPC3 device on the SRX5000 line devices. The control interfaces ixlv0 and igb0 are used to configure
the SRX5K-RE3-128G device.Control links control the communication between the control plane, data
plane, and heartbeat messages.

Single Control Link in a Chassis Cluster

For a single control link in a chassis cluster, you must use the same control port for the control link
connection and for configuration on both nodes.

For example, if you configure port 0 as a control port on node 0, you must configure port 0 as a control
port on node 1. You must connect the ports with a cable.

Dual Control Link in a Chassis Cluster

You must connect dual control links in a chassis cluster directly. Cross connections—that is, connecting
port 0 on one node to port 1 on the other node and vice versa—do not work.

For dual control links, you must make these connections:

• Connect control port 0 on node 0 to control port 0 on node 1.

• Connect control port 1 on node 0 to control port 1 on node 1.

Encryption on Chassis Cluster Control Link

Chassis cluster control links support an optional encrypted security feature that you can configure and
activate.

NOTE: Note that Juniper Networks security documentation uses chassis cluster when referring
to high availability (HA) control links. You will still see the abbreviation ha used in place of chassis
cluster in commands.

The control link access prevents hackers from logging in to the system without authentication through
the control link, with Telnet access disabled. Using the internal IPsec key for internal communication
between devices, the configuration information that passes through the chassis cluster link from the
primary node to the secondary node is encrypted. Without the IPsec key, an attacker cannot gain
privilege access or observe traffic.
70

To enable this feature, run the set security ipsec internal security-association manual encryption ike-ha-link-
encryption enable configuration command.

You must reboot both the nodes to activate this configuration.

Encryption on chassis cluster control link using IPsec is supported on SRX4600 line devices, SRX5000
line devices, and vSRX Virtual Firewall platforms.

When the chassis cluster is running with the IPsec key configured already, then you can make any
changes to the key without rebooting the device. In this case, you will have to change the key only on
one node.

When IPsec key encryption is configured, for any configuration changes under internal security
association (SA) hierarchy, you must reboot both the nodes. To verify the configured Internet Key
Exchange (IKE) chassis cluster link encryption algorithm, view the output of show security internal-
security-association.

Table 10 on page 70 lists the supported control ports on the SRX Series Firewalls.
Table 10: Supported Control Ports on SRX Series Firewalls

SRX Series Firewalls Description

SRX5400, SRX5600, and SRX5800 By default, all control ports are disabled. Each Services
Processing Card (SPC) in a device has two control
ports, and each device can have multiple SPCs plugged
in to it. To set up the control link in a chassis cluster,
you connect and configure the control ports that you
use on each device (fpc<n> and fpc<n>), and then
initialize the device in cluster mode.

SRX4600 Dedicated chassis cluster control ports and fabric ports


are available.

No control link configuration is needed for SRX4600


devices; however, you need to configure fabric link
ports explicitly for chassis cluster deployments. If you
want to configure 1-Gigabit Ethernet interfaces for the
control ports, you must explicitly set the speed using
the operational CLI command statement set chassis
cluster control-port speed 1g. See speed (Chassis
Cluster).
71

Table 10: Supported Control Ports on SRX Series Firewalls (Continued)

SRX Series Firewalls Description

SRX4100 and SRX4200 Dedicated chassis cluster control ports are available.
Control link configuration is not required. For more
information about all SRX4100 ports and SRX4200
ports, including dedicated control links ports and fabric
link ports, see Understanding SRX Series Chassis
Cluster Slot Numbering and Physical Port and Logical
Interface Naming.

When devices are not in cluster mode, dedicated


chassis cluster ports cannot be used as revenue ports
or traffic ports.

SRX1500 Devices use the dedicated control port.

SRX300, SRX320, SRX340, SRX345, SRX380, and Control link uses the ge-0/0/1 interface.
SRX550M

For details about port usage and interface usage for management links, control links, and fabric links, see
Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming.

Example: Configure Chassis Cluster Control Ports for Control Link

IN THIS SECTION

Requirements | 72

Overview | 72

Configuration | 72

This example shows how to configure chassis cluster control ports on these devices: SRX5400,
SRX5600, and SRX5800. You need to configure the control ports that you will use on each device to set
up the control link.
72

Requirements
Before you begin:

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

• Physically connect the control ports on the devices. See "Connecting SRX Series Devices to Create a
Chassis Cluster" on page 34.

Overview
Control link traffic passes through the switches in the Services Processing Cards (SPCs) and reaches the
other node. On SRX Series Firewalls, chassis cluster ports are located at the SPCs in the chassis cluster.
By default, all control ports on SRX5400 devices, SRX5600 devices, and SRX5800 devices are disabled.
To set up the control links, you connect the control ports, configure the control ports, and set up the
chassis cluster.

This example configures control ports with the following Flexible PIC Concentrators (FPCs) and ports as
the control link:

• FPC 4, port 0

• FPC 10, port 0

Configuration

IN THIS SECTION

Procedure | 72

Verify the Chassis Cluster Status | 74

Verify Chassis Cluster Control Plane Statistics | 74

Procedure

CLI Quick Configuration

To quickly configure this section of the example, copy the following commands, paste them into a text
file, remove any line breaks, change any details necessary to match your network configuration, copy
73

and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit in configuration
mode.

{primary:node0}[edit]
set chassis cluster control-ports fpc 4 port 0
set chassis cluster control-ports fpc 10 port 0
{primary:node1}[edit]
set chassis cluster control-ports fpc 4 port 0
set chassis cluster control-ports fpc 10 port 0

Step-by-Step Procedure

To configure control ports as the control link for the chassis cluster:

Specify the control ports.

{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 4 port 0
{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 10 port 0
{primary:node1}[edit]
user@host# set chassis cluster control-ports fpc 4 port 0
{primary:node1}[edit]
user@host# set chassis cluster control-ports fpc 10 port 0

Results

In configuration mode, confirm your configuration by entering the show chassis cluster command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

user@host# show chassis cluster


...
control-ports {
fpc 4 port 0;
74

fpc 10 port 0;
}
...

After you configure the device, enter commit in configuration mode.

Verify the Chassis Cluster Status

Purpose

Verify the chassis cluster status.

Action

In operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 100 primary no no
node1 1 secondary no no

Redundancy group: 1 , Failover count: 1


node0 0 primary no no
node1 0 secondary no no

Meaning

Use the show chassis cluster status command to confirm that the devices in the chassis cluster are
communicating with each other. The preceding output shows that chassis cluster is functioning properly,
as one device is the primary node and the other is the secondary node.

Verify Chassis Cluster Control Plane Statistics

Purpose

Display chassis cluster control plane statistics.


75

Action

At the CLI, enter the show chassis cluster control-plane statistics command:

{primary:node1}
user@host> show chassis cluster control-plane statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 124
Heartbeat packets received: 125
Fabric link statistics:
Child link 0
Probes sent: 124
Probes received: 125

{primary:node1}
user@host> show chassis cluster control-plane statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 258698
Heartbeat packets received: 258693
Control link 1:
Heartbeat packets sent: 258698
Heartbeat packets received: 258693
Fabric link statistics:
Child link 0
Probes sent: 258690
Probes received: 258690
Child link 1
Probes sent: 258505
Probes received: 258505

SEE ALSO

Configuring Chassis Clustering on SRX Series Devices | 129


76

SEE ALSO

Connecting SRX Series Firewalls to Create a Chassis Cluster | 34


Chassis Cluster Dual Control Links | 172

Clear Chassis Cluster Control Plane Statistics

To clear displayed chassis cluster control plane statistics, enter the clear chassis cluster control-plane
statistics command at the CLI:

{primary:node1}
user@host> clear chassis cluster control-plane statistics

Cleared control-plane statistics

SCB Chassis Cluster Control Links

For SRX Series Firewalls SRX5400, SRX5600, and SRX5800, you can connect the control links in a
chassis cluster using the Switch Control Board (SCB) chassis cluster control ports.

Increase the resiliency of the chassis cluster by separating chassis cluster control links from Services
Processing Card (SPC).

The SCB chassis cluster control link path is independent of SPCs. The SPC failures do not affect the
chassis cluster control link.

The supported 10-Gigabit (Gb) SFPP connections on the SCB external 10-Gigabit Ethernet (10GbE)
ports are as follows:

• SCB2 chassis cluster port: SFPP-10GE-LR, SFPP-10GE-SR, SFPP-10GE-LRM

• SCB3 chassis cluster port and SCB4 chassis cluster port: SFPP-10GE-LR, SFPP-10GE-SR
77

Figure 27: SCB Chassis Cluster Control Link Path

The control port connections on the chassis cluster are as follows:

• Chassis cluster control port 0 is on SCB0.

• Routing Engine 0 is on SCB0.

• SCB chassis cluster port 0 is used to replace SPC chassis cluster port 0.

SEE ALSO

request chassis primary-ha-control-port-transition | 759


request chassis fpc-control-port | 755
scb-control-ports | 709

Change from Chassis Cluster to Standalone Mode

Change from cluster mode to standalone mode when using single primary control link.
78

1. Disable the chassis cluster and reboot the devices to enter the standalone mode.

user@host> set chassis cluster disable reboot

2. Enable the chassis cluster and reboot the devices to enter the chassis cluster mode.

Example: Configure Control Ports Using the SCB Control Link

IN THIS SECTION

Requirements | 78

Overview | 78

Configuration | 79

Verification | 80

This example shows how to configure a chassis cluster with two standalone nodes using a single SCB
control link.

Requirements
Before you begin:

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

Overview
Configure the control ports that you will use on each device to set up the control link.

You must not configure the following control links at the same time:

• SPC and SCB primary control links

• SPC and SCB secondary control links


79

Configuration

IN THIS SECTION

Procedure | 79

Procedure

To configure a chassis cluster using a single SCB control link:

1. Connect an SCB control link cable between the SCB0 chassis cluster control ports on node 0 and
node 1.

2. Configure an SCB control port (primary control link) on node 0 and node 1.

user@host# set chassis cluster scb-control-ports 0

3. Reboot node 0.

user@host> set chassis cluster cluster-id 2 node 0 reboot

4. Reboot node 1.

user@host> set chassis cluster cluster-id 2 node 1 reboot

Results

In configuration mode, confirm your configuration by entering the show chassis cluster command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.

user@host# show chassis cluster


scb-control-ports {
80

0;
}

After you configure the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verify the Chassis Cluster Status | 80

Verify the Chassis Cluster Status

Purpose

You can verify the chassis cluster status and run the show chassis fpc pic-status command to ensure
that the FPCs are online.

Action

In operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring RE Relinquish monitoring
IS IRQ storm

Cluster ID: 2
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
81

node1 1 secondary no no None

Redundancy group: 1 , Failover count: 1


node0 200 primary no no None
node1 199 secondary no no None

In operational mode, enter the show chassis fpc pic-status command.

{primary:node0}
user@host> show chassis fpc pic-status
node0:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

node1:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

In operational mode, enter the show chassis cluster control-plane statistics command to view the statistics
of the control link used by chassis cluster traffic.

{primary:node0}
user@host> show chassis cluster control-plane statistics
Control link statistics:
Control link 0:
Heartbeat packets sent: 459759
Heartbeat packets received: 459107
Heartbeat packet errors: 0
Node 0 SCB HA port TX FCS Errors: 0
Node 0 SCB HA port RX FCS Errors: 0
Node 1 SCB HA port TX FCS Errors: 0
82

Node 1 SCB HA port RX FCS Errors: 0


Control link 1:
Heartbeat packets sent: 0
Heartbeat packets received: 0
Heartbeat packet errors: 0
Node 0 SCB HA port TX FCS Errors: NA
Node 0 SCB HA port RX FCS Errors: NA
Node 1 SCB HA port TX FCS Errors: NA
Node 1 SCB HA port RX FCS Errors: NA
Fabric link statistics:
Child link 0
Probes sent: 1835526
Probes received: 1834285
Child link 1
Probes sent: 0
Probes received: 0

Meaning

Use the show chassis cluster control-plane statistics command to view the control link statistics and fabric
link statistics exchanging heartbeats.

Transition from SPC to SCB with a Single Control Link

IN THIS SECTION

Requirements | 82

Overview | 83

Configuration | 83

This example provides steps for the chassis cluster control link transition from a single SPC control link
to a single SCB control link concurrently.

Requirements
Before you begin:
83

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

Overview
After completing the control link transition, ensure that you disconnect the SPC control link cables that
existed before the control link transition. You must disconnect the secondary SCB control cable when
you configure only the primary control link.

Configuration

IN THIS SECTION

Procedure | 83

Procedure

To transition from SPC to SCB control links concurrently:

1. During a single control link transition, heartbeats may be missing for a short time. The secondary
node may detect the missing heartbeats and go into an ineligible state. To prevent the secondary
node from entering an ineligible state, configure it to extend the control link heartbeat timeout
from 3 seconds (the default) to 16 seconds.

user@host# set chassis cluster heartbeat-interval 2000 heartbeat-threshold 8

2. Disable the SCB 0 chassis cluster control port on the primary node using the operational command.

{primary:node0}
user@host> test chassis ethernet-switch shell-cmd "port xe0 enable=0"

3. Verify the SCB 0 chassis cluster control port status on the primary node.

{primary:node0}
user@host> test chassis ethernet-switch shell-cmd ps | grep xe0
xe0 !ena 10G FD SW No Forward TX RX None FA XGMII 16356
84

4. Enable the SCB 0 chassis cluster control port on the secondary node.

{secondary:node1}
user@host> test chassis ethernet-switch shell-cmd "port xe0 enable=1"

5. Verify the SCB 0 chassis cluster control port status on the secondary node.

{secondary:node1}
user@host> test chassis ethernet-switch shell-cmd ps | grep xe0
xe0 down 10G FD SW No Forward TX RX None FA XGMII 16356

6. Connect the SCB primary control link cable.

7. Transition from the SPC control link to the SCB control link on the primary node by disabling SPC
chassis cluster port 0 on the primary node and enabling SCB chassis cluster port 0 on the primary
node. Here the SPC slot number is the one on which the SPC chassis cluster control port is
configured.

{primary:node0}
user@host> request chassis primary-ha-control-port-transition from-fpc-to-scb fpc 4
fpc 4 HA control port 0 disabled & scb 0 HA control port enabled

8. Delete the SPC primary control link configuration.

{primary:node0}[edit]
user@host# delete chassis cluster control-ports

9. Configure the SCB primary control link.

{primary:node0}[edit]
user@host# set chassis cluster scb-control-ports 0
user@host# commit
node0:
configuration check succeeds
node1:
commit complete
85

node0:
commit complete

10. Verify that the control link is up, using the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 ixlv0 Up Disabled Disabled
1 igb0 Down Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-3/0/7 Up / Up Disabled
fab0
fab1 xe-15/0/7 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

{primary:node0}
user@host> show chassis fpc pic-status
node0:
--------------------------------------------------------------------------
Slot 0 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
86

Slot 2 Online SRX5k SPC II


PIC 0 Online SPU Flow
PIC 1 Online SPU Flow
PIC 2 Online SPU Flow
PIC 3 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

node1:
--------------------------------------------------------------------------
Slot 0 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 2 Online SRX5k SPC II
PIC 0 Online SPU Flow
PIC 1 Online SPU Flow
PIC 2 Online SPU Flow
PIC 3 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

11. Delete the control link heartbeat timeout.

user@host# delete chassis cluster heartbeat-interval 2000 heartbeat-threshold 8

12. Disconnect the SPC primary control link cable.

Transition from SCB to SPC with a Single Control Link

IN THIS SECTION

Requirements | 87

Configuration | 87
87

This example shows how to configure a control link transition from an SCB control link to an SPC control
link.

Requirements
Before you begin:

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

Configuration

IN THIS SECTION

Procedure | 87

Procedure

To transition from an SCB control link to an SPC control link concurrently:

1. During a single SCB control link transition, heartbeats may be missing for a short time. The
secondary node may detect the missing heartbeats and enter an ineligible state. To prevent the
secondary node from entering an ineligible state, configure it to extend the control link heartbeat
timeout from 3 seconds (the default) to 16 seconds.

user@host# set chassis cluster heartbeat-interval 2000 heartbeat-threshold 8

2. Disable SPC chassis cluster control port 0 on the primary node. fpc 4 is the local slot number on
which the chassis cluster control port will be configured later.

{primary:node0}
user@host> request chassis fpc-control-port disable fpc 4 port 0
fpc 4 HA port 0 disabled
88

3. Enable SPC chassis cluster control port 0 on the secondary node. fpc 4 is the local slot number on
which the chassis cluster control port will be configured later.

{secondary:node1}
user@host> request chassis fpc-control-port enable fpc 4 port 0
fpc 4 HA port 0 enabled

4. Connect the SPC primary control link cable.

5. Transition from the SCB control link to the SPC control link by disabling SCB chassis cluster control
port 0 on the primary node and enabling SPC chassis cluster port 0 on the primary node. Here the
SPC slot number is the one on which the SPC chassis cluster control port will be configured.

{primary:node0}
user@host> request chassis primary-ha-control-port-transition from-scb-to-fpc fpc 4
scb 0 HA control port disabled & fpc 4 HA control port 0 enabled

6. Delete the primary SCB control link configuration.

{primary:node0}[edit]
user@host# delete chassis cluster scb-control-ports

7. Configure the primary SPC control link.

{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 4 port 0
user@host# set chassis cluster control-ports fpc 10 port 0
user@host# commit
node0:
configuration check succeeds
node1:
commit complete
node0:
commit complete
89

8. Verify if the control link is up, using the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 ixlv0 Up Disabled Disabled
1 igb0 Down Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-3/0/7 Up / Up Disabled
fab0
fab1 xe-15/0/7 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

{primary:node0}
user@host> show chassis fpc pic-status
node0:
--------------------------------------------------------------------------
Slot 0 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 2 Online SRX5k SPC II
PIC 0 Online SPU Flow
PIC 1 Online SPU Flow
PIC 2 Online SPU Flow
90

PIC 3 Online SPU Flow


Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

node1:
--------------------------------------------------------------------------
Slot 0 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 2 Online SRX5k SPC II
PIC 0 Online SPU Flow
PIC 1 Online SPU Flow
PIC 2 Online SPU Flow
PIC 3 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

9. Delete the control link heartbeat timeout.

user@host# delete chassis cluster heartbeat-interval 2000 heartbeat-threshold 8

10. Disconnect the SCB primary control link cable.

Release History Table


Release Description

19.3R1 Starting in Junos OS Release 19.3R1, the SRX5K-RE3-128G is supported along with SRX5K-SPC3 on
the SRX5000 line devices. The control interfaces ixlv0 and igb0 are used to configure SRX5K-
RE3-128G.Control links control the communication between the control, and data plane and the
heartbeat messages.

RELATED DOCUMENTATION

Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming | 18
Example: Configure Chassis Clustering on SRX Series Firewalls | 130
91

Chassis Cluster Redundancy Groups

IN THIS SECTION

Understanding Chassis Cluster Redundancy Groups | 91

Example: Configuring Chassis Cluster Redundancy Groups | 95

A redundancy group (RG) includes and manages a collection of objects on both nodes of a cluster. An RG
is primary on one node and backup on the other node at any given time. For more information, see the
following topics:

Understanding Chassis Cluster Redundancy Groups

IN THIS SECTION

Understanding Chassis Cluster Redundancy Group 0: Routing Engines | 92

Understanding Chassis Cluster Redundancy Groups 1 Through 128 | 93

Chassis clustering provides high availability of interfaces and services through redundancy groups and
primacy within groups.

A redundancy group is an abstract construct that includes and manages a collection of objects. A
redundancy group contains objects on both nodes. A redundancy group is primary on one node and
backup on the other at any time. When a redundancy group is said to be primary on a node, its objects
on that node are active.

Redundancy groups are independent units of failover. Each redundancy group fails over from one node
to the other independent of other redundancy groups. When a redundancy group fails over, all its
objects fail over together.

Three things determine the primacy of a redundancy group: the priority configured for the node, the
node ID (in case of tied priorities), and the order in which the node comes up. If a lower priority node
comes up first, then it will assume the primacy for a redundancy group (and will stay as primary if
92

preempt is not enabled). If preempt is added to a redundancy group configuration, the device with the
higher priority in the group can initiate a failover to become primary. By default, preemption is disabled.
For more information on preemption, see "preempt (Chassis Cluster)" on page 679.

A chassis cluster can include many redundancy groups, some of which might be primary on one node
and some of which might be primary on the other. Alternatively, all redundancy groups can be primary
on a single node. One redundancy group's primacy does not affect another redundancy group's primacy.
You can create up to 128 redundancy groups.

The maximum number of redundancy groups is equal to the number of redundant Ethernet interfaces
that you configure.

You can configure redundancy groups to suit your deployment. You configure a redundancy group to be
primary on one node and backup on the other node. You specify the node on which the group is primary
by setting priorities for both nodes within a redundancy group configuration. The node with the higher
priority takes precedence, and the redundancy group's objects on it are active.

If a redundancy group is configured so that both nodes have the same priority, the node with the lowest
node ID number always takes precedence, and the redundancy group is primary on it. In a two-node
cluster, node 0 always takes precedence in a priority tie.

Understanding Chassis Cluster Redundancy Group 0: Routing Engines

When you initialize a device in chassis cluster mode, the system creates a redundancy group referred to
as redundancy group 0. Redundancy group 0 manages the primacy and failover between the Routing
Engines on each node of the cluster. As is the case for all redundancy groups, redundancy group 0 can
be primary on only one node at a time. The node on which redundancy group 0 is primary determines
which Routing Engine is active in the cluster. A node is considered the primary node of the cluster if its
Routing Engine is the active one.

The redundancy group 0 configuration specifies the priority for each node. The following priority
scheme determines redundancy group 0 primacy. Note that the three-second value is the interval if the
default heartbeat-threshold and heartbeat-interval values are used.

• The node that comes up first (at least three seconds prior to the other node) is the primary node.

• If both nodes come up at the same time (or within three seconds of each other):

• The node with the higher configured priority is the primary node.

• If there is a tie (either because the same value was configured or because default settings were
used), the node with the lower node ID (node 0) is the primary node.

The previous priority scheme applies to redundancy groups x (redundancy groups numbered 1 through
128) as well, provided preempt is not configured. (See "Example: Configuring Chassis Cluster
Redundancy Groups" on page 95.)
93

You cannot enable preemption for redundancy group 0. If you want to change the primary node for
redundancy group 0, you must do a manual failover.

Be cautious and judicious in your use of redundancy group 0 manual failovers. A redundancy group 0
failover implies a Routing Engine failover, in which case all processes running on the primary node are
killed and then spawned on the new primary Routing Engine. This failover could result in loss of state,
such as routing state, and degrade performance by introducing system churn.

Understanding Chassis Cluster Redundancy Groups 1 Through 128

You can configure one or more redundancy groups numbered 1 through 128, referred to as redundancy
group x. The maximum number of redundancy groups is equal to the number of redundant Ethernet
interfaces that you configure (see "Maximum Number of Redundant Ethernet Interfaces Allowed
(SRX4100, SRX4200, SRX4600, SRX5400, SRX5600, SRX5800, SRX300, SRX320, SRX340, SRX345,
SRX 380, SRX550M and SRX1500)" on page 100). Each redundancy group x acts as an independent unit
of failover and is primary on only one node at a time.

Each redundancy group x contains one or more redundant Ethernet interfaces. A redundant Ethernet
interface is a pseudo interface that contains at minimum a pair of physical Gigabit Ethernet interfaces or
a pair of Fast Ethernet interfaces. If a redundancy group is active on node 0, then the child links of all the
associated redundant Ethernet interfaces on node 0 are active. If the redundancy group fails over to
node 1, then the child links of all redundant Ethernet interfaces on node 1 become active.

The following priority scheme determines redundancy group x primacy, provided preempt is not
configured. If preempt is configured, the node with the higher priority is the primary node. Note that the
three-second value is the interval if the default heartbeat-threshold and heartbeat-interval values are used.

• The node that comes up first (at least three seconds prior to the other node) is the primary node.

• If both nodes come up at the same time (or within three seconds of each other):

• The node with the higher configured priority is the primary node.

• If there is a tie (either because the same value was configured or because default settings were
used), the node with the lower node ID (node 0) is the primary node.

On SRX Series chassis clusters, you can configure multiple redundancy groups to load-share traffic
across the cluster. For example, you can configure some redundancy groups x to be primary on one node
and some redundancy groups x to be primary on the other node. You can also configure a redundancy
group x in a one-to-one relationship with a single redundant Ethernet interface to control which
interface traffic flows through.

The traffic for a redundancy group is processed on the node where the redundancy group is active.
Because more than one redundancy group can be configured, it is possible that the traffic from some
redundancy groups is processed on one node while the traffic for other redundancy groups is processed
on the other node (depending on where the redundancy group is active). Multiple redundancy groups
94

make it possible for traffic to arrive over an ingress interface of one redundancy group and over an
egress interface that belongs to another redundancy group. In this situation, the ingress and egress
interfaces might not be active on the same node. When this happens, the traffic is forwarded over the
fabric link to the appropriate node.

When you configure a redundancy group x, you must specify a priority for each node to determine the
node on which the redundancy group x is primary. The node with the higher priority is selected as
primary. The primacy of a redundancy group x can fail over from one node to the other. When a
redundancy group x fails over to the other node, its redundant Ethernet interfaces on that node are
active and their interfaces are passing traffic.

Table 11 on page 94 gives an example of redundancy group x in an SRX Series chassis cluster and
indicates the node on which the group is primary. It shows the redundant Ethernet interfaces and their
interfaces configured for redundancy group x.

Some devices have both Gigabit Ethernet ports and Fast Ethernet ports.

Table 11: Example of Redundancy Groups in a Chassis Cluster

Group Primary Priority Objects Interface (Node 0) Interface


(Node 1)

Redundancy Node 0 Node 0: Routing Engine on — —


group 0 254 node 0

Node 1: 2 Routing Engine on — —


node 1

Redundancy Node 0 Node 0: Redundant Ethernet ge-1/0/0 ge-5/0/0


group 1 254 interface 0

Node 1: 2 Redundant Ethernet ge-1/3/0 ge-5/3/0


interface 1

Redundancy Node 1 Node 0: 2 Redundant Ethernet ge-2/0/0 ge-6/0/0


group 2 interface 2

Node 1: Redundant Ethernet ge-2/3/0 ge-6/3/0


254 interface 3
95

Table 11: Example of Redundancy Groups in a Chassis Cluster (Continued)

Group Primary Priority Objects Interface (Node 0) Interface


(Node 1)

Redundancy Node 0 Node 0: Redundant Ethernet ge-3/0/0 ge-7/0/0


group 3 254 interface 4

Node 1: 2 Redundant Ethernet ge-3/3/0 ge-7/3/0


interface 5

As the example for a chassis cluster in Table 11 on page 94 shows:

• The Routing Engine on node 0 is active because redundancy group 0 is primary on node 0. (The
Routing Engine on node 1 is passive, serving as backup.)

• Redundancy group 1 is primary on node 0. Interfaces ge-1/0/0 and ge-1/3/0 belonging to redundant
Ethernet interface 0 and redundant Ethernet interface 1 are active and handling traffic.

• Redundancy group 2 is primary on node 1. Interfaces ge-6/0/0 and ge-6/3/0 belonging to redundant
Ethernet interface 2 and redundant Ethernet interface 3 are active and handling traffic.

• Redundancy group 3 is primary on node 0. Interfaces ge-3/0/0 and ge-3/3/0 belonging to redundant
Ethernet interface 4 and redundant Ethernet interface 5 are active and handling traffic.

Example: Configuring Chassis Cluster Redundancy Groups

IN THIS SECTION

Requirements | 96

Overview | 96

Configuration | 96

Verification | 98

This example shows how to configure a chassis cluster redundancy group.


96

Requirements
Before you begin:

1. Set the chassis cluster node ID and cluster ID. See "Example: Setting the Chassis Cluster Node ID and
Cluster ID" on page 40.

2. Configure the chassis cluster management interface. See "Example: Configuring the Chassis Cluster
Management Interface" on page 46.

3. Configure the chassis cluster fabric. See "Example: Configuring the Chassis Cluster Fabric Interfaces"
on page 60.

Overview
A chassis cluster redundancy group is an abstract entity that includes and manages a collection of
objects. Each redundancy group acts as an independent unit of failover and is primary on only one node
at a time.

In this example, you create two chassis cluster redundancy groups, 0 and 1:

• 0—Node 0 is assigned a priority of 100, and node 1 is assigned a priority of 1.

• 1—Node 0 is assigned a priority of 100, and node 1 is assigned a priority of 1.

The preempt option is enabled, and the number of gratuitous ARP requests that an interface can send to
notify other network devices of its presence after the redundancy group it belongs to has failed over is
4.

Configuration

IN THIS SECTION

Procedure | 97
97

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

[edit]
set chassis cluster redundancy-group 0 node 0 priority 100
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 100
set chassis cluster redundancy-group 1 node 1 priority 1
set chassis cluster redundancy-group 1 preempt
set chassis cluster redundancy-group 1 gratuitous-arp-count 4

Step-by-Step Procedure

To configure a chassis cluster redundancy group:

1. Specify a redundancy group's priority for primacy on each node of the cluster. The higher number
takes precedence.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 0 node 0 priority 100
user@host# set chassis cluster redundancy-group 0 node 1 priority 1
user@host# set chassis cluster redundancy-group 1 node 0 priority 100
user@host# set chassis cluster redundancy-group 1 node 1 priority 1

2. Configure the node with the higher priority to preempt the device with the lower priority and
become primary for the redundancy group.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 preempt

You cannot enable preemption for redundancy group 0. If you want to change the primary node for
redundancy group 0, you must do a manual failover.
98

3. Specify the number of gratuitous ARP requests that an interface can send to notify other network
devices of its presence after the redundancy group it belongs to has failed over.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 gratuitous-arp-count 4

Results

From configuration mode, confirm your configuration by entering the show chassis cluster status
redundancy-group commands. If the output does not display the intended configuration, repeat the
configuration instructions in this example to correct it.

{primary:node0}[edit]
user@host# show chassis cluster
chassis {
cluster {
redundancy-group 0 {
node 0 priority 100;
node 1 priority 1;
}
redundancy-group 1 {
node 0 priority 100;
node 1 priority 1;
preempt;
gratuitous-arp-count 4;
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying Chassis Cluster Redundancy Group Status | 99


99

Verifying Chassis Cluster Redundancy Group Status

Purpose

Verify the status of a chassis cluster redundancy group.

Action

From operational mode, enter the show chassis cluster status redundancy-group command.

{primary:node0}
user@host>show chassis cluster status redundancy-group 1

Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 1 , Failover count: 1


node0 100 primary no no
node1 1 secondary yes no

Chassis Cluster Redundant Ethernet Interfaces

IN THIS SECTION

Understanding Chassis Cluster Redundant Ethernet Interfaces | 100

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces | 103

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces on SRX4600 | 111

Example: Configuring IP-over-IP Tunnel on SRX Series Firewalls | 119

A redundant Ethernet (reth) interface is a pseudo-interface that includes minimum one physical interface
from each node of a cluster. A reth interface of the active node is responsible for passing the traffic in a
chassis cluster setup. For more information, see the following topics:
100

Understanding Chassis Cluster Redundant Ethernet Interfaces

IN THIS SECTION

IP-over-IP Tunneling | 103

For SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M, SRX1500, SRX4100, and SRX4200
devices, the total number of logical interfaces that you can configure across all the redundant Ethernet
(reth) interfaces in a chassis cluster deployment is 1024.

For SRX5800, SRX5600, SRX5400, and SRX4600 devices, the total number of logical interfaces that you
can configure across all the redundant Ethernet (reth) interfaces in a chassis cluster deployment is 4096.

For SRX550M devices, the total number of logical interfaces that you can configure across all the
redundant Ethernet (reth) interfaces in a chassis cluster deployment is 1024.

Starting with Junos OS Release 12.1X45-D10 and later, sampling features such as flow monitoring,
packet capture, and port mirroring are supported on reth interfaces.

A redundant Ethernet interface must contain, at minimum, a pair of Fast Ethernet interfaces or a pair of
Gigabit Ethernet interfaces that are referred to as child interfaces of the redundant Ethernet interface
(the redundant parent). If two or more child interfaces from each node are assigned to the redundant
Ethernet interface, a redundant Ethernet interface link aggregation group can be formed. A single
redundant Ethernet interface might include a Fast Ethernet interface from node 0 and a Fast Ethernet
interface from node 1 or a Gigabit Ethernet interface from node 0 and a Gigabit Ethernet interface from
node 1.

On SRX5600, and SRX5800 devices, interfaces such as 10-Gigabit Ethernet (xe), 40-Gigabit Ethernet,
and 100-Gigabit Ethernet can be redundant Ethernet (reth) interfaces.

SRX4100 and SRX4200 devices support 10-Gigabit Ethernet (xe) interfaces as redundant Ethernet (reth)
interfaces.

A redundant Ethernet interface is referred to as a reth in configuration commands.

A redundant Ethernet interface's child interface is associated with the redundant Ethernet interface as
part of the child interface configuration. The redundant Ethernet interface child interface inherits most
of its configuration from its parent.

The maximum number of redundant Ethernet interfaces that you can configure varies, depending on the
device type you are using, as shown in Table 12 on page 101. The number of redundant Ethernet
101

interfaces configured determines the number of redundancy groups that can be configured in the SRX
Series Firewalls.

Table 12: Maximum Number of Redundant Ethernet Interfaces Allowed (SRX4100, SRX4200,
SRX4600, SRX5400, SRX5600, SRX5800, SRX300, SRX320, SRX340, SRX345, SRX 380, SRX550M
and SRX1500)

Device Maximum Number of reth Interfaces

SRX4600 128

SRX4100, SRX4200 128

SRX5400, SRX5600, SRX5800 128

SRX300, SRX320, SRX340, SRX345,SRX380 128

SRX550M 58

SRX1500 128

You can enable promiscuous mode on redundant Ethernet interfaces. When promiscuous mode is
enabled on a Layer 3 Ethernet interface, all packets received on the interface are sent to the central
point or Services Processing Unit (SPU), regardless of the destination MAC address of the packet. If you
enable promiscuous mode on a redundant Ethernet interface, promiscuous mode is then enabled on any
child physical interfaces.

To enable promiscuous mode on a redundant Ethernet interface, use the promiscuous-mode statement at
the [edit interfaces] hierarchy.

A redundant Ethernet interface inherits its failover properties from the redundancy group x that it
belongs to. A redundant Ethernet interface remains active as long as its primary child interface is
available or active. For example, if reth0 is associated with redundancy group 1 and redundancy group 1
is active on node 0, then reth0 is up as long as the node 0 child of reth0 is up.

Point-to-Point Protocol over Ethernet (PPPoE) over redundant Ethernet (reth) interface is supported on
SRX300, SRX320, SRX340, SRX345, SRX380, SRX550M and SRX1500 devices in chassis cluster mode.
This feature allows an existing PPPoE session to continue without starting a new PPP0E session in the
event of a failover.

On SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices, the number of child interfaces
is restricted to 16 on the reth interface (eight per node).
102

When using SRX Series Firewalls in chassis cluster mode, it is not recommended to configure any local
interfaces (or combination of local interfaces) along with redundant Ethernet interfaces.

For example:

The following configuration of chassis cluster with redundant Ethernet interfaces in which interfaces are
configured as local interfaces:

ge-2/0/2 {
unit 0 {
family inet {
address 10.1.1.1/24;
}
}
}

The following configuration of chassis cluster redundant Ethernet interfaces, in which interfaces are
configured as part of redundant Ethernet interfaces, is supported:

interfaces {
ge-2/0/2 {
gigether-options {
redundant-parent reth2;
}
}
reth2 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 10.1.1.1/24;
}
}
}
}

You can enable promiscuous mode on redundant Ethernet interfaces. When promiscuous mode is
enabled on a Layer 3 Ethernet interface, all packets received on the interface are sent to the central
point or Services Processing Unit (SPU), regardless of the destination MAC address of the packet. If you
enable promiscuous mode on a redundant Ethernet interface, promiscuous mode is then enabled on any
child physical interfaces.
103

To enable promiscuous mode on a redundant Ethernet interface, use the promiscuous-mode statement at
the [edit interfaces] hierarchy.

IP-over-IP Tunneling

IP-over-IP tunneling is supported over the reth interface in SRX chassis cluster configuration. Tunneling
allows the encapsulation of one IP packet over another IP packet.

The tunnel configuration is created on both the primary and secondary devices. The traffic passing
through the IP-IP tunnel is synced from primary device to secondary device. The tunnel configuration on
secondary device is considered as backup and active in the event of failure of the primary device. The
traffic resumes on the secondary device in the event of the failure of the primary.

On SRX Series Firewalls, Generic Routing Encapsulation (GRE) and IP-IP tunnels use internal interfaces,
gr-0/0/0 and ip-0/0/0, respectively. The Junos OS creates these interfaces at system bootup; they are
not associated with physical interfaces.

SEE ALSO

Understanding Link Aggregation Groups in a Chassis Cluster | 298

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces

IN THIS SECTION

Requirements | 104

Overview | 104

Configuration | 104

Verification | 109

This example shows how to configure chassis cluster redundant Ethernet interfaces. A redundant
Ethernet interface is a pseudointerface that contains two or more physical interfaces, with at least one
from each node of the cluster.
104

Requirements
Before you begin:

• Understand how to set the chassis cluster node ID and cluster ID. See "Example: Setting the Chassis
Cluster Node ID and Cluster ID" on page 40.

• Set the number of redundant Ethernet interfaces.

• Understand how to set the chassis cluster fabric. See "Example: Configuring the Chassis Cluster
Fabric Interfaces" on page 60.

• Understand how to set the chassis cluster node redundancy groups. See "Example: Configuring
Chassis Cluster Redundancy Groups" on page 95.

Overview
After physical interfaces have been assigned to the redundant Ethernet interface, you set the
configuration that pertains to them at the level of the redundant Ethernet interface, and each of the
child interfaces inherits the configuration.

If multiple child interfaces are present, then the speed of all the child interfaces must be the same.

A redundant Ethernet interface is referred to as a reth in configuration commands.

You can enable promiscuous mode on redundant Ethernet interfaces. When promiscuous mode is
enabled on a Layer 3 Ethernet interface, all packets received on the interface are sent to the central
point or Services Processing Unit regardless of the destination MAC address of the packet. If you enable
promiscuous mode on a redundant Ethernet interface, promiscuous mode is then enabled on any child
physical interfaces.

To enable promiscuous mode on a redundant Ethernet interface, use the promiscuous-mode statement
at the [edit interfaces] hierarchy.

Configuration

IN THIS SECTION

Configuring Chassis Cluster Redundant Ethernet Interfaces for IPv4 Addresses | 105

Configuring Chassis Cluster Redundant Ethernet Interfaces for IPv6 Addresses | 106

Results | 108
105

Configuring Chassis Cluster Redundant Ethernet Interfaces for IPv4 Addresses

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set interfaces ge-0/0/0 gigether-options redundant-parent reth1
set interfaces ge-7/0/0 gigether-options redundant-parent reth1
set interfaces fe-1/0/0 fast-ether-options redundant-parent reth2
set interfaces fe-8/0/0 fast-ether-options redundant-parent reth2
set interfaces reth1 redundant-ether-options redundancy-group 1
set interfaces reth1 unit 0 family inet mtu 1500
set interfaces reth1 unit 0 family inet address 10.1.1.3/24
set security zones security-zone Trust interfaces reth1.0

Step-by-Step Procedure

To configure redundant Ethernet interfaces for IPv4:

1. Bind redundant child physical interfaces to reth1.

{primary:node0}[edit]
user@host# set interfaces ge-0/0/0 gigether-options redundant-parent reth1
user@host# set interfaces ge-7/0/0 gigether-options redundant-parent reth1

2. Bind redundant child physical interfaces to reth2.

{primary:node0}[edit]
user@host# set interfaces fe-1/0/0 fast-ether-options redundant-parent reth2
user@host# set interfaces fe-8/0/0 fast-ether-options redundant-parent reth2

3. Add reth1 to redundancy group 1.

{primary:node0}[edit]
user@host# set interfaces reth1 redundant-ether-options redundancy-group 1
106

4. Set the MTU size.

{primary:node0}[edit]
user@host# set interfaces reth1 unit 0 family inet mtu 1500

The maximum transmission unit (MTU) set on the reth interface can be different from the MTU on
the child interface.

5. Assign an IP address to reth1.

{primary:node0}[edit]
user@host# set interfaces reth1 unit 0 family inet address 10.1.1.3/24

6. Associate reth1.0 to the trust security zone.

{primary:node0}[edit]
user@host# set security zones security-zone Trust interfaces reth1.0

Configuring Chassis Cluster Redundant Ethernet Interfaces for IPv6 Addresses

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set interfaces ge-0/0/0 gigether-options redundant-parent reth1
set interfaces ge-7/0/0 gigether-options redundant-parent reth1
set interfaces fe-1/0/0 fast-ether-options redundant-parent reth2
set interfaces fe-8/0/0 fast-ether-options redundant-parent reth2
set interfaces reth2 redundant-ether-options redundancy-group 1
set interfaces reth2 unit 0 family inet6 mtu 1500
set interfaces reth2 unit 0 family inet6 address 2010:2010:201::2/64
set security zones security-zone Trust interfaces reth2.0
107

Step-by-Step Procedure

To configure redundant Ethernet interfaces for IPv6:

1. Bind redundant child physical interfaces to reth1.

{primary:node0}[edit]
user@host# set interfaces ge-0/0/0 gigether-options redundant-parent reth1
user@host# set interfaces ge-7/0/0 gigether-options redundant-parent reth1

2. Bind redundant child physical interfaces to reth2.

{primary:node0}[edit]
user@host# set interfaces fe-1/0/0 fast-ether-options redundant-parent reth2
user@host# set interfaces fe-8/0/0 fast-ether-options redundant-parent reth2

3. Add reth2 to redundancy group 1.

{primary:node0}[edit]
user@host# set interfaces reth2 redundant-ether-options redundancy-group 1

4. Set the MTU size.

{primary:node0}[edit]
user@host# set interfaces reth2 unit 0 family inet6 mtu 1500

5. Assign an IP address to reth2.

{primary:node0}[edit]
user@host# set interfaces reth2 unit 0 family inet6 address 2010:2010:201::2/64

6. Associate reth2.0 to the trust security zone.

{primary:node0}[edit]
user@host# set security zones security-zone Trust interfaces reth2.0
108

Step-by-Step Procedure

To set the number of redundant Ethernet interfaces for a chassis cluster:

1. Specify the number of redundant Ethernet interfaces:

{primary:node0}[edit]

user@host# set chassis cluster reth-count 2

Results

From configuration mode, confirm your configuration by entering the show interfaces command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

{primary:node0}[edit]
user@host# show interfaces
interfaces {
...
fe-1/0/0 {
fastether-options {
redundant-parent reth2;
}
}
fe-8/0/0 {
fastether-options {
redundant-parent reth2;
}
}
ge-0/0/0 {
gigether-options {
redundant-parent reth1;
}
}
ge-7/0/0 {
gigether-options {
redundant-parent reth1;
109

}
}
reth1 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
mtu 1500;
address 10.1.1.3/24;
}
}
}
reth2 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet6 {
mtu 1500;
address 2010:2010:201::2/64;
}
}
}
...
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying Chassis Cluster Redundant Ethernet Interfaces | 110

Verifying Chassis Cluster Control Links | 110

Confirm that the configuration is working properly.


110

Verifying Chassis Cluster Redundant Ethernet Interfaces

Purpose

Verify the configuration of the chassis cluster redundant Ethernet interfaces.

Action

From operational mode, enter the show interfaces terse | match reth1 command:

{primary:node0}
user@host> show interfaces terse | match reth1

ge-0/0/0.0 up up aenet --> reth1.0


ge-7/0/0.0 up up aenet --> reth1.0
reth1 up up
reth1.0 up up inet 10.1.1.3/24

Verifying Chassis Cluster Control Links

Purpose

Verify information about the control interface in a chassis cluster configuration.

Action

From operational mode, enter the show chassis cluster interfaces command:

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Up Disabled Disabled
1 em1 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
111

Name Child-interface Status Security


(Physical/Monitored)
fab0 xe-3/0/6 Up / Up Enabled
fab0
fab1 xe-9/0/6 Up / Up Enabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1

SEE ALSO

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces | 103

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces on


SRX4600

IN THIS SECTION

Requirements | 111

Overview | 112

Configuration | 112

Verification | 116

This example shows how to configure child links or physical links on SRX4600 device in chassis cluster
mode.

Requirements
Before you begin:

• Understand how to set the chassis cluster node ID and cluster ID. See "Example: Setting the Chassis
Cluster Node ID and Cluster ID" on page 40.
112

• Understand how to set the chassis cluster node redundancy groups. See "Example: Configuring
Chassis Cluster Redundancy Groups" on page 95.

Overview
You can configure up to eight number of child links for a reth bundle on SRX4600 devices per chassis.

Configuration

IN THIS SECTION

CLI Quick Configuration | 112

Configuring redundant Ethernet interfaces | 113

Results | 114

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set interfaces xe-1/0/0:0 gigether-options redundant-parent reth0
set interfaces xe-1/0/0:1 gigether-options redundant-parent reth0
set interfaces xe-1/0/0:2 gigether-options redundant-parent reth0
set interfaces xe-1/0/0:3 gigether-options redundant-parent reth0
set interfaces xe-1/0/1:0 gigether-options redundant-parent reth0
set interfaces xe-1/0/1:1 gigether-options redundant-parent reth0
set interfaces xe-1/0/1:2 gigether-options redundant-parent reth0
set interfaces xe-1/0/1:3 gigether-options redundant-parent reth0
set interfaces xe-1/1/0 gigether-options redundant-parent reth1
set interfaces xe-1/1/1 gigether-options redundant-parent reth1
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 family inet address 192.0.2.1/24
set interfaces reth1 redundant-ether-options redundancy-group 1
set interfaces reth1 redundant-ether-options lacp active
set interfaces reth1 unit 0 family inet address 198.51.100.1/24
set security zones security-zone Trust-zone interfaces reth0.0
113

set security zones security-zone Untrust-zone interfaces reth1.0


set chassis cluster reth-count 10

Configuring redundant Ethernet interfaces

Step-by-Step Procedure

To configure redundant Ethernet interfaces:

1. Bind eight redundant child physical interfaces to reth0.

{primary:node0}[edit]
user@host# set interfaces xe-1/0/0:0 gigether-options redundant-parent reth0
user@host# set interfaces xe-1/0/0:1 gigether-options redundant-parent reth0
user@host# set interfaces xe-1/0/0:2 gigether-options redundant-parent reth0
user@host# set interfaces xe-1/0/0:3 gigether-options redundant-parent reth0
user@host# set interfaces xe-1/0/1:0 gigether-options redundant-parent reth0
user@host# set interfaces xe-1/0/1:1 gigether-options redundant-parent reth0
user@host# set interfaces xe-1/0/1:2 gigether-options redundant-parent reth0
user@host# set interfaces xe-1/0/1:3 gigether-options redundant-parent reth0

2. Bind redundant child physical interfaces to reth1.

{primary:node0}[edit]
user@host# set interfaces xe-1/1/0 gigether-options redundant-parent reth1
user@host# set interfaces xe-1/1/1 gigether-options redundant-parent reth1

3. Specify the number of redundant Ethernet interfaces:

{primary:node0}[edit]

user@host# set chassis cluster reth-count 10

4. Add reth0 to redundancy group 1.

{primary:node0}[edit]
user@host# set interfaces reth0 redundant-ether-options redundancy-group 1
114

5. Assign an IP address to reth0.

{primary:node0}[edit]
user@host# set interfaces reth0 unit 0 family inet address 192.0.2.1/24

6. Add reth1 to redundancy group1.

{primary:node0}[edit]
user@host# set interfaces reth1 redundant-ether-options redundancy-group 1
user@host# set interfaces reth1 redundant-ether-options lacp active

7. Assign an IP address to reth1.

{primary:node0}[edit]
user@host# set interfaces reth1 unit 0 family inet address 198.51.100.1/24

8. Associate reth0.0 to the trust security zone.

{primary:node0}[edit]
user@host# set security zones security-zone Trust-zone interfaces reth0.0

9. Associate reth1.0 to untrust security zone.

{primary:node0}[edit]
user@host# set security zones security-zone Untrust-zone interfaces reth1.0

Results

From configuration mode, confirm your configuration by entering the show interfaces command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

{primary:node0}[edit]
user@host# show interfaces
115

xe-1/0/0:0 {
gigether-options {
redundant-parent reth0;
}
}
xe-1/0/0:1 {
gigether-options {
redundant-parent reth0;
}
}
xe-1/0/0:2 {
gigether-options {
redundant-parent reth0;
}
}
xe-1/0/0:3 {
gigether-options {
redundant-parent reth0;
}
}
xe-1/0/1:0 {
gigether-options {
redundant-parent reth0;
}
}
xe-1/0/1:1 {
gigether-options {
redundant-parent reth0;
}
}
xe-1/0/1:2 {
gigether-options {
redundant-parent reth0;
}
}
xe-1/0/1:3 {
gigether-options {
redundant-parent reth0;
}
}
xe-1/1/0 {
gigether-options {
redundant-parent reth1;
116

}
}
xe-1/1/1 {
gigether-options {
redundant-parent reth1;
}
}
reth0 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 192.0.2.1/24;
}
}
}
reth1 {
redundant-ether-options {
redundancy-group 1;
lacp {
active;
}
}
unit 0 {
family inet {
address 198.51.100.1/24;
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verify Chassis Cluster Redundant Ethernet Interfaces | 117

Verifying Chassis Cluster Control Links | 117


117

Confirm that the configuration is working properly.

Verify Chassis Cluster Redundant Ethernet Interfaces

Purpose

Verify the configuration of the chassis cluster redundant Ethernet interfaces on SRX4600 device.

Action

From operational mode, enter the show interfaces terse | match reth0 command:

{primary:node0}
user@host> show interfaces terse | match reth0

xe-1/0/0:0.0 up down aenet --> reth0.0


xe-1/0/0:1.0 up down aenet --> reth0.0
xe-1/0/0:2.0 up down aenet --> reth0.0
xe-1/0/0:3.0 up down aenet --> reth0.0
xe-1/0/1:0.0 up down aenet --> reth0.0
xe-1/0/1:1.0 up down aenet --> reth0.0
xe-1/0/1:2.0 up down aenet --> reth0.0
xe-1/0/1:3.0 up down aenet --> reth0.0
reth0 up down
reth0.0 up down inet 192.0.2.1/24

Meaning

You can view the maximum number of configured child link interfaces of a reth bundle from four to eight
in one chassis.

Verifying Chassis Cluster Control Links

Purpose

Verify information about the control interface in a chassis cluster configuration.


118

Action

From operational mode, enter the show chassis cluster interfaces command:

{primary:node0}
user@host> show chassis cluster interfaces

Control link status: Down

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Down Disabled Disabled
1 em1 Down Disabled Disabled

Fabric link status: Down

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-0/0/2 Up / Down Disabled
fab0

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down 1
reth1 Up 1
reth2 Down Not configured
reth3 Down Not configured
reth4 Down Not configured
reth5 Down Not configured
reth6 Down Not configured
reth7 Down Not configured
reth8 Down Not configured
reth9 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0
119

Example: Configuring IP-over-IP Tunnel on SRX Series Firewalls

IN THIS SECTION

Requirements | 119

Overview | 119

Topology | 119

Configuration | 120

Verification | 125

This example shows how to create IP-IP tunnel with a forwarding next-hop to pass IPv4 traffic through
the tunnel and synchronize the configuration from primary device to secondary device.

Requirements
Before you begin:

• Understand how to set the chassis cluster node ID and cluster ID. See "Example: Setting the Chassis
Cluster Node ID and Cluster ID" on page 40.

This example uses the following hardware and software components:

• Junos OS Release 23.1R1 or later version.

• SRX345 Device

Overview
Packets are routed to an internal interface where they are encapsulated with an IP packet and then
forwarded to the encapsulating packet's destination address. The IP-IP interface is an internal interface
only and is not associated with a physical interface. You must configure the interface for it to perform IP
tunneling.

Topology
Figure 28 on page 120 Illustrates IP-over-IP scenario with SRX Series Firewalls operating in chassis
cluster mode.
120

Figure 28: Configuring SRX Series Firewalls using IP-IP Tunnel

Configuration

IN THIS SECTION

Configuring IP-IP tunnel with Chassis Cluster Redundant Ethernet Interfaces for IPv4 Addresses | 120

Results | 123

Configuring IP-IP tunnel with Chassis Cluster Redundant Ethernet Interfaces for IPv4 Addresses

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set chassis cluster reth-count 2
set chassis cluster redundancy-group 0 node 0 priority 100
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 100
set chassis cluster redundancy-group 1 node 1 priority 1

set interfaces reth0 redundant-ether-options redundancy-group 1


set interfaces reth1 redundant-ether-options redundancy-group 1
121

set interfaces reth0 unit 0 family inet address 22.0.0.254/24

set interfaces reth1 unit 0 family inet address 1.0.0.254/24

set interfaces ip-0/0/0 unit 0 tunnel source 22.0.0.254


set interfaces ip-0/0/0 unit 0 tunnel destination 22.0.0.200
set interfaces ip-0/0/0 unit 0 family inet address 33.0.0.254/24

set interfaces ge-0/0/1 gigether-options redundant-parent reth0


set interfaces ge-0/0/2 gigether-options redundant-parent reth1
set interfaces ge-7/0/1 gigether-options redundant-parent reth0
set interfaces ge-7/0/2 gigether-options redundant-parent reth1

set interfaces fab0 fabric-options member-interfaces ge-0/0/0


set interfaces fab1 fabric-options member-interfaces ge-7/0/0

{peer}
set interfaces ip-0/0/0 unit 0 tunnel source 22.0.0.200
set interfaces ip-0/0/0 unit 0 tunnel destination 22.0.0.254
set interfaces ip-0/0/0 unit 0 family inet address 33.0.0.200/24
set interfaces ge-0/0/1 unit 0 family inet address 22.0.0.200/24
set interfaces ge-0/0/2 unit 0 family inet address 2.0.0.200/24
set routing-options static route 1.0.0.0/24 next-hop ip-0/0/0.0

Step-by-Step Procedure

To configure redundant Ethernet interfaces for IPv4:

1. Set up redundancy group 0 for the Routing Engine failover properties, and set up redundancy group
1 (all interfaces are in one redundancy group in this example) to define the failover properties for the
redundant Ethernet interfaces.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 0 node 0 priority 100
user@host# set chassis cluster redundancy-group 0 node 1 priority 1
user@host# set chassis cluster redundancy-group 1 node 0 priority 100
user@host# set chassis cluster redundancy-group 1 node 1 priority 1
122

2. Set up the redundant Ethernet (reth) interfaces.

{primary:node0}[edit]
user@host# set chassis cluster reth-count 2
user@host# set interfaces ge-0/0/1 gigether-options redundant-parent reth0
user@host# set interfaces ge-0/0/2 gigether-options redundant-parent reth1
user@host# set interfaces ge-7/0/1 gigether-options redundant-parent reth0
user@host# set interfaces ge-7/0/2 gigether-options redundant-parent reth1
user@host# set interfaces reth0 redundant-ether-options redundancy-group 1
user@host# set interfaces reth0 unit 0 family inet address 22.0.0.254/24
user@host# set interfaces reth1 redundant-ether-options redundancy-group 1
user@host# set interfaces reth1 unit 0 family inet address 1.0.0.254/24

3. Configure tunnel over redundant ethernet interface on both the nodes.

{primary:node0}[edit]
user@host# set interfaces ip-0/0/0 unit 0 tunnel source 22.0.0.254
user@host# set interfaces ip-0/0/0 unit 0 tunnel destination 22.0.0.200
user@host# set interfaces ip-0/0/0 unit 0 family inet address 33.0.0.254/24

4. Configure tunnel session on the peer.

{peer}
user@host# set interfaces ip-0/0/0 unit 0 tunnel source 22.0.0.200
user@host# set interfaces ip-0/0/0 unit 0 tunnel destination 22.0.0.254
user@host# set interfaces ip-0/0/0 unit 0 family inet address 33.0.0.200/24
user@host# set interfaces ge-0/0/1 unit 0 family inet address 22.0.0.200/24
user@host# set interfaces ge-0/0/2 unit 0 family inet address 2.0.0.200/24
user@host# set routing-options static route 1.0.0.0/24 next-hop ip-0/0/0.0

5. Configure routing-options on both the nodes:

{primary:node0}
set routing-options static route 2.0.0.0/24 next-hop ip-0/0/0.0
123

6. Configure fabric interfaces on both the nodes.

{primary:node0}[edit]
user@host# set interfaces fab0 fabric-options member-interfaces ge-0/0/0
user@host# set interfaces fab1 fabric-options member-interfaces ge-7/0/0

Results

From configuration mode, confirm your configuration by entering the show interfaces command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

{primary:node0}[edit]
user@host# show interfaces
ip-0/0/0 {
unit 0 {
tunnel {
source 22.0.0.254;
destination 22.0.0.200;
}
family inet {
address 33.0.0.254/24;
}
}
}
ge-0/0/1 {
gigether-options {
redundant-parent reth0;
}
}
ge-0/0/2 {
gigether-options {
redundant-parent reth1;
}
}
ge-7/0/1 {
gigether-options {
redundant-parent reth0;
124

}
}
ge-7/0/2 {
gigether-options {
redundant-parent reth1;
}
}
fab0 {
fabric-options {
member-interfaces {
ge-0/0/0;
}
}
}
fab1 {
fabric-options {
member-interfaces {
ge-7/0/0;
}
}
}
reth0 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 22.0.0.254/24;
}
}
}
reth1 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 1.0.0.254/24;
}
}
}
125

Verification

IN THIS SECTION

Purpose | 125

Action | 125

Meaning | 128

Purpose

Display the information about chassis cluster interfaces and status.

Action

From operational mode, enter the show chassis cluster interfaces,show chassis cluster status, and show
security flow session command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 fxp1 Up Disabled Disabled

Fabric link status: Down

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 ge-0/0/0 Up / Up Disabled
fab0
fab1 ge-0/0/7 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
126

reth1 Up 1

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring RE Relinquish monitoring
IS IRQ storm

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 200 primary no no None
node1 100 secondary no no None

Redundancy group: 1 , Failover count: 1


node0 200 primary no no None
node1 100 secondary no no None

{primary:node0}
user@host> show security flow session
node0:
--------------------------------------------------------------------------

Session ID: 6323, Policy name: N/A, HA State: Active, Timeout: N/A, Session State: Valid
In: 2012::2:2/1 --> 2012::2:1/1;ipip, Conn Tag: 0x0, If: reth1.0, Pkts: 0, Bytes: 0,

Session ID: 6324, Policy name: N/A, HA State: Active, Timeout: N/A, Session State: Valid
In: 2012::2:2/1 --> 2012::2:1/1;ipv6, Conn Tag: 0x0, If: reth1.0, Pkts: 0, Bytes: 0,
127

Session ID: 6361, Policy name: self-traffic-policy/1, HA State: Active, Timeout: 56, Session
State: Valid
In: fe80::2:2/1 --> ff02::5/1;ospf, Conn Tag: 0x0, If: ip-0/0/0.1, Pkts: 153842, Bytes:
12371296,
Out: ff02::5/1 --> fe80::2:2/1;ospf, Conn Tag: 0x0, If: .local..0, Pkts: 0, Bytes: 0,

Session ID: 6362, Policy name: self-traffic-policy/1, HA State: Active, Timeout: 52, Session
State: Valid
In: 100.0.2.2/1 --> 224.0.0.5/1;ospf, Conn Tag: 0x0, If: ip-0/0/0.1, Pkts: 152030, Bytes:
12178352,
Out: 224.0.0.5/1 --> 100.0.2.2/1;ospf, Conn Tag: 0x0, If: .local..0, Pkts: 0, Bytes: 0,

Session ID: 6363, Policy name: self-traffic-policy/1, HA State: Active, Timeout: 60, Session
State: Valid
In: 100.0.2.2/49152 --> 100.0.2.1/3784;udp, Conn Tag: 0x0, If: ip-0/0/0.1, Pkts: 1509142,
Bytes: 78475384,
Out: 100.0.2.1/3784 --> 100.0.2.2/49152;udp, Conn Tag: 0x0, If: .local..0, Pkts: 0, Bytes: 0,

Session ID: 6364, Policy name: self-traffic-policy/1, HA State: Active, Timeout: 60, Session
State: Valid
In: fe80::2:2/49152 --> fe80::2:1/3784;udp, Conn Tag: 0x0, If: ip-0/0/0.1, Pkts: 1509355,
Bytes: 108673560,
Out: fe80::2:1/3784 --> fe80::2:2/49152;udp, Conn Tag: 0x0, If: .local..0, Pkts: 0, Bytes: 0,
Total sessions: 6

node1:
--------------------------------------------------------------------------

Session ID: 1304, Policy name: N/A, HA State: Backup, Timeout: N/A, Session State: Valid
In: 2012::2:2/1 --> 2012::2:1/1;ipip, Conn Tag: 0x0, If: reth1.0, Pkts: 0, Bytes: 0,

Session ID: 1305, Policy name: N/A, HA State: Backup, Timeout: N/A, Session State: Valid
In: 2012::2:2/1 --> 2012::2:1/1;ipv6, Conn Tag: 0x0, If: reth1.0, Pkts: 0, Bytes: 0,

Session ID: 1306, Policy name: self-traffic-policy/1, HA State: Backup, Timeout: 1482, Session
State: Valid
In: 100.0.2.2/49152 --> 100.0.2.1/3784;udp, Conn Tag: 0x0, If: ip-0/0/0.1, Pkts: 0, Bytes: 0,
Out: 100.0.2.1/3784 --> 100.0.2.2/49152;udp, Conn Tag: 0x0, If: .local..0, Pkts: 0, Bytes: 0,

Session ID: 1307, Policy name: self-traffic-policy/1, HA State: Backup, Timeout: 1538, Session
State: Valid
In: fe80::2:2/49152 --> fe80::2:1/3784;udp, Conn Tag: 0x0, If: ip-0/0/0.1, Pkts: 0, Bytes: 0,
Out: fe80::2:1/3784 --> fe80::2:2/49152;udp, Conn Tag: 0x0, If: .local..0, Pkts: 0, Bytes: 0,
128

Total sessions: 4

{primary:node0}
user@host> show security flow statistics
node0:
--------------------------------------------------------------------------
Current sessions: 6
Packets received: 12528819
Packets transmitted: 12523469
Packets forwarded/queued: 44
Packets copied: 0
Packets dropped: 5306
Services-offload packets processed: 0
Fragment packets: 0
Pre fragments generated: 0
Post fragments generated: 0

node1:
--------------------------------------------------------------------------
Current sessions: 4
Packets received: 1608551
Packets transmitted: 1588679
Packets forwarded/queued: 0
Packets copied: 0
Packets dropped: 19874
Services-offload packets processed: 0
Fragment packets: 0
Pre fragments generated: 0
Post fragments generated: 0

Meaning

The chassis cluster configuration displays the reth interface as the bind interface to exchange routes
through IP-over-IP tunnel.
129

Release History Table

Release Description

12.1X45-D10 Starting with Junos OS Release 12.1X45-D10 and later, sampling features such as flow monitoring,
packet capture, and port mirroring are supported on reth interfaces.

RELATED DOCUMENTATION

Example: Configure Chassis Clustering on SRX Series Firewalls | 130


Example: Enabling Eight-Queue Class of Service on Redundant Ethernet Interfaces on SRX Series
Firewalls in a Chassis Cluster | 153

Configuring Chassis Clustering on SRX Series


Devices

IN THIS SECTION

Example: Configure Chassis Clustering on SRX Series Firewalls | 130

Viewing a Chassis Cluster Configuration | 147

Viewing Chassis Cluster Statistics | 148

Clearing Chassis Cluster Statistics | 150

Understanding Automatic Chassis Cluster Synchronization Between Primary and Secondary Nodes | 151

Verifying Chassis Cluster Configuration Synchronization Status | 152

SRX Series Services gateways can be configured to operate in cluster mode, where a pair of devices can
be connected together and configured to operate like a single device to provide high availability. When
configured as a chassis cluster, the two nodes back up each other, with one node acting as the primary
device and the other as the secondary device, ensuring stateful failover of processes and services in the
event of system or hardware failure. If the primary device fails, the secondary device takes over
processing of traffic.

For SRX300, SRX320, SRX340, SRX345, and SRX380 devices, connect ge-0/0/1 on node 0 to ge-0/0/1
on node 1. The factory-default configuration does not include HA configuration. To enable HA, if the
130

physical interfaces used by HA have some configurations, these configurations need to be removed.
Table 13 on page 130 lists the physical interfaces used by HA on SRX300, SRX320, SRX340, SRX345,
and SRX380.

Table 13: Mapping Between HA Interface and Physical Interface on SRX300, SRX320, SRX340,
SRX345, and SRX380

Device fxp0 Interface (HA MGT) fxp1 Interface (HA Control) Fab Interface

SRX300 ge-0/0/0 ge-0/0/1 User defined

SRX320 ge-0/0/0 ge-0/0/1 User defined

SRX340 dedicated ge-0/0/1 User defined

SRX345 dedicated ge-0/0/1 User defined

SRX380 dedicated ge-0/0/1 User defined

For more information, see the following topics:

Example: Configure Chassis Clustering on SRX Series Firewalls

IN THIS SECTION

Requirements | 131

Overview | 132

Configuration | 133

Verification | 142

This example shows how to set up chassis clustering on an SRX Series Firewall (using SRX1500 as
example).
131

Requirements
Before you begin:

• Physically connect the two devices and ensure that they are the same models. For example, on the
SRX1500 Firewall, connect the dedicated control ports on node 0 and node 1.

• Set the two devices to cluster mode and reboot the devices. You must enter the following
operational mode commands on both devices, for example:

• On node 0:

user@host> set chassis cluster cluster-id 1 node 0 reboot

• On node 1:

user@host> set chassis cluster cluster-id 1 node 1 reboot

The cluster-id is the same on both devices, but the node ID must be different because one device is
node 0 and the other device is node 1. The range for the cluster-id is 0 through 255 and setting it to
0 is equivalent to disabling cluster mode.

• After clustering occurs for the devices, continuing with the SRX1500 Firewall example, the ge-0/0/0
interface on node 1 changes to ge-7/0/0.

After clustering occurs,

• For SRX300 devices, the ge-0/0/1 interface on node 1 changes to ge-1/0/1.

• For SRX320 devices, the ge-0/0/1 interface on node 1 changes to ge-3/0/1.

• For SRX340 and SRX345 devices, the ge-0/0/1 interface on node 1 changes to ge-5/0/1.

After the reboot, the following interfaces are assigned and repurposed to form a cluster:

• For SRX300 and SRX320 devices, ge-0/0/0 becomes fxp0 and is used for individual management
of the chassis cluster.

• SRX340 and SRX345 devices contain a dedicated port fxp0.

• For all SRX300, SRX320, SRX340, SRX345, and SRX380 devices, ge-0/0/1 becomes fxp1 and is
used as the control link within the chassis cluster.

• The other interfaces are also renamed on the secondary device.


132

See "Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical
Interface Naming" on page 18 for complete mapping of the SRX Series Firewalls.

From this point forward, configuration of the cluster is synchronized between the node members and
the two separate devices function as one device.

Overview
This example shows how to set up chassis clustering on an SRX Series Firewall using the SRX1500
device as example.

The node 1 renumbers its interfaces by adding the total number of system FPCs to the original FPC
number of the interface. See Table 14 on page 132 for interface renumbering on the SRX Series Firewall.

Table 14: SRX Series Firewalls Interface Renumbering

SRX Series Services Gateway Renumbering Constant Node 0 Interface Name Node 1 Interface Name

SRX300 1 ge-0/0/0 ge-1/0/0

SRX320 3 ge-0/0/0 ge-3/0/0

SRX340 5 ge-0/0/0 ge-5/0/0

SRX345

SRX380

SRX550M 9 ge-0/0/0 ge-9/0/0

SRX1500 7 ge-0/0/0 ge-7/0/0

After clustering is enabled, the system creates fxp0, fxp1, and em0 interfaces. Depending on the device,
the fxp0, fxp1, and em0 interfaces that are mapped to a physical interface are not user defined.
However, the fab interface is user defined.

Figure 29 on page 133 shows the topology used in this example.


133

Figure 29: SRX Series Firewalls (SRX1500) In Chassis Cluster

Configuration

IN THIS SECTION

Procedure | 133

Procedure

CLI Quick Configuration

To quickly configure a chassis cluster on an SRX1500 Firewall, copy the following commands and paste
them into the CLI:

On {primary:node0}

[edit]
set groups node0 system host-name srx1500-1
set groups node0 interfaces fxp0 unit 0 family inet address 192.16.35.46/24
set groups node1 system host-name srx1500-2
134

set groups node1 interfaces fxp0 unit 0 family inet address 192.16.35.47/24
set groups node0 system backup-router <backup next-hop from fxp0> destination <management
network/mask>
set groups node1 system backup-router <backup next-hop from fxp0> destination <management
network/mask>
set apply-groups "${node}"
set interfaces fab0 fabric-options member-interfaces ge-0/0/1
set interfaces fab1 fabric-options member-interfaces ge-7/0/1
set chassis cluster redundancy-group 0 node 0 priority 100
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 100
set chassis cluster redundancy-group 1 node 1 priority 1
set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-7/0/5 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-7/0/4 weight 255
set chassis cluster reth-count 2
set interfaces ge-0/0/5 gigether-options redundant-parent reth1
set interfaces ge-7/0/5 gigether-options redundant-parent reth1
set interfaces reth1 redundant-ether-options redundancy-group 1
set interfaces reth1 unit 0 family inet address 203.0.113.233/24
set interfaces ge-0/0/4 gigether-options redundant-parent reth0
set interfaces ge-7/0/4 gigether-options redundant-parent reth0
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 family inet address 198.51.100.1/24
set security zones security-zone Untrust interfaces reth1.0
set security zones security-zone Trust interfaces reth0.0

If you are configuring SRX300, SRX320, SRX340, SRX345, SRX380 and SRX550M devices, see Table 15
on page 135 for command and interface settings for your device and substitute these commands into
your CLI.
135

Table 15: SRX Series Firewalls Interface Settings

Command SRX300 SRX320 SRX340 SRX550M

SRX345

SRX380

set interfaces fab0 ge-0/0/2 ge-0/0/2 ge-0/0/2 ge-0/0/2


fabric-options member-
interfaces

set interfaces fab1 ge-1/0/2 ge-3/0/2 ge-5/0/2 ge-9/0/2


fabric-options member-
interfaces

set chassis cluster ge-0/0/3 weight 255 ge-0/0/3 weight 255 ge-0/0/3 weight 255 ge-1/0/0 weight 255
redundancy-group 1
interface-monitor

set chassis cluster ge-0/0/4 weight 255 ge-0/0/4 weight 255 ge-0/0/4 weight 255 ge-10/0/0 weight
redundancy-group 1 255
interface-monitor

set chassis cluster ge-1/0/3 weight 255 ge-3/0/3 weight 255 ge-5/0/3 weight 255 ge-1/0/1 weight 255
redundancy-group 1
interface-monitor

set chassis cluster ge-1/0/4 weight 255 ge-3/0/4 weight 255 ge-5/0/4 weight 255 ge-10/0/1 weight
redundancy-group 1 255
interface-monitor

set interfaces ge-0/0/3 gigether- ge-0/0/3 gigether- ge-0/0/3 gigether- ge-1/0/0 gigether-
options redundant- options redundant- options redundant- options redundant-
parent reth0 parent reth0 parent reth0 parent reth1
136

Table 15: SRX Series Firewalls Interface Settings (Continued)

Command SRX300 SRX320 SRX340 SRX550M

SRX345

SRX380

set interfaces ge-0/0/4 gigether- ge-0/0/4 gigether- ge-0/0/4 gigether-


ge-10/0/0 gigether-
options redundant- options redundant- options redundant-
options redundant-
parent reth1 parent reth1 parent reth1
parent reth1

set interfaces ge-1/0/3 gigether- ge-3/0/3 gigether- ge-5/0/3 gigether- ge-1/0/1 gigether-
options redundant- options redundant- options redundant- options redundant-
parent reth0 parent reth0 parent reth0 parent reth0

set interfaces ge-1/0/4 gigether- ge-3/0/4 gigether- ge-5/0/4 gigether- ge-10/0/1 gigether-
options redundant- options redundant- options redundant- options redundant-
parent reth1 parent reth1 parent reth1 parent reth0

Step-by-Step Procedure

The following example requires you to navigate various levels in the configuration hierarchy. For
instructions on how to do that, see Using the CLI Editor in Configuration Mode in the CLI User Guide.

To configure a chassis cluster on an SRX Series Firewall:

Perform Steps 1 through 5 on the primary device (node 0). They are automatically copied over to the
secondary device (node 1) when you execute a commit command. The configurations are synchronized
because the control link and fab link interfaces are activated. To verify the configurations, use the show
interface terse command and review the output.

1. Set up hostnames and management IP addresses for each device using configuration groups. These
configurations are specific to each device and are unique to its specific node.

user@host# set groups node0 system host-name srx1500-1


user@host# set groups node0 interfaces fxp0 unit 0 family inet address 192.16.35.46/24
user@host# set groups node1 system host-name srx1500-2
user@host# set groups node1 interfaces fxp0 unit 0 family inet address 192.16.35.47/24
137

Set the default route and backup router for each node.

user@host# set groups node0 system backup-router <backup next-hop from fxp0> destination
<management network/mask>
user@host# set groups node1 system backup-router <backup next-hop from fxp0> destination
<management network/mask>

Set the apply-group command so that the individual configurations for each node set by the previous
commands are applied only to that node.

user@host# set apply-groups "${node}"

2. Define the interfaces used for the fab connection (data plane links for RTO sync) by using physical
ports ge-0/0/1 from each node. These interfaces must be connected back-to-back, or through a
Layer 2 infrastructure.

user@host# set interfaces fab0 fabric-options member-interfaces ge-0/0/1


user@host# set interfaces fab1 fabric-options member-interfaces ge-7/0/1

3. Set up redundancy group 0 for the Routing Engine failover properties, and set up redundancy group
1 (all interfaces are in one redundancy group in this example) to define the failover properties for the
redundant Ethernet interfaces.

user@host# set chassis cluster redundancy-group 0 node 0 priority 100


user@host# set chassis cluster redundancy-group 0 node 1 priority 1
user@host# set chassis cluster redundancy-group 1 node 0 priority 100
user@host# set chassis cluster redundancy-group 1 node 1 priority 1

4. Set up interface monitoring to monitor the health of the interfaces and trigger redundancy group
failover.

We do not recommend Interface monitoring for redundancy group 0 because it causes the control
plane to switch from one node to another node in case interface flap occurs.

user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 255


user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-7/0/5 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-7/0/4 weight 255
138

Interface failover only occurs after the weight reaches 0.

5. Set up the redundant Ethernet (reth) interfaces and assign the redundant interface to a zone.

user@host# set chassis cluster reth-count 2


user@host# set interfaces ge-0/0/5 gigether-options redundant-parent reth1
user@host# set interfaces ge-7/0/5 gigether-options redundant-parent reth1
user@host# set interfaces reth1 redundant-ether-options redundancy-group 1
user@host# set interfaces reth1 unit 0 family inet address 203.0.113.233/24
user@host# set interfaces ge-0/0/4 gigether-options redundant-parent reth0
user@host# set interfaces ge-7/0/4 gigether-options redundant-parent reth0
user@host# set interfaces reth0 redundant-ether-options redundancy-group 1
user@host# set interfaces reth0 unit 0 family inet address 198.51.100.1/24
user@host# set security zones security-zone Untrust interfaces reth1.0
user@host# set security zones security-zone Trust interfaces reth0.0

Results

From operational mode, confirm your configuration by entering the show configuration command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

> show configuration


version x.xx.x;
groups {
node0 {
system {
host-name SRX1500-1;
backup-router 10.100.22.1 destination 66.129.243.0/24;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.16.35.46/24;
}
}
}
139

}
}
node1 {
system {
host-name SRX1500-2;
backup-router 10.100.21.1 destination 66.129.243.0/24; }
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.16.35.47/24;
}
}
}
}
}
}
apply-groups "${node}";
chassis {
cluster {
reth-count 2;
redundancy-group 0 {
node 0 priority 100;
node 1 priority 1;
}
redundancy-group 1 {
node 0 priority 100;
node 1 priority 1;
interface-monitor {
ge–0/0/5 weight 255;
ge–0/0/4 weight 255;
ge–7/0/5 weight 255;
ge–7/0/4 weight 255;
}
}
}
}
interfaces {
ge–0/0/5 {
gigether–options {
redundant–parent reth1;
}
}
140

ge–0/0/4 {
gigether–options {
redundant–parent reth0;
}
}
ge–7/0/5 {
gigether–options {
redundant–parent reth1;
}
}
ge–7/0/4 {
gigether–options {
redundant–parent reth0;
}
}
fab0 {
fabric–options {
member–interfaces {
ge–0/0/1;
}
}
}
fab1 {
fabric–options {
member–interfaces {
ge–7/0/1;
}
}
}
reth0 {
redundant–ether–options {
redundancy–group 1;
}
unit 0 {
family inet {
address 198.51.100.1/24;
}
}
}
reth1 {
redundant–ether–options {
redundancy–group 1;
}
141

unit 0 {
family inet {
address 203.0.113.233/24;
}
}
}
}
...
security {
zones {
security–zone Untrust {
interfaces {
reth1.0;
}
}
security–zone Trust {
interfaces {
reth0.0;
}
}
}
policies {
from–zone Trust to–zone Untrust {
policy 1 {
match {
source–address any;
destination–address any;
application any;
}
then {
permit;
}
}
}
}
}

If you are done configuring the device, enter commit from configuration mode.
142

Verification

IN THIS SECTION

Verifying Chassis Cluster Status | 142

Verifying Chassis Cluster Interfaces | 143

Verifying Chassis Cluster Statistics | 143

Verifying Chassis Cluster Control Plane Statistics | 144

Verifying Chassis Cluster Data Plane Statistics | 145

Verifying Chassis Cluster Redundancy Group Status | 146

Troubleshooting with Logs | 146

Confirm that the configuration is working properly.

Verifying Chassis Cluster Status

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host# show chassis cluster status
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 100 primary no no
node1 1 secondary no no

Redundancy group: 1 , Failover count: 1


node0 0 primary no no
node1 0 secondary no no
143

Verifying Chassis Cluster Interfaces

Purpose

Verify information about chassis cluster interfaces.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link name: em0

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-7/0/5 255 Up 1
ge-7/0/4 255 Up 1
ge-0/0/5 255 Up 1
ge-0/0/4 255 Up 1

Verifying Chassis Cluster Statistics

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitored interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster statistics command.

{primary:node0}
user@host> show chassis cluster statistics
144

Control link statistics:


Control link 0:
Heartbeat packets sent: 2276
Heartbeat packets received: 2280
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 2272
Probes received: 597
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 6 0
Session create 161 0
Session close 148 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Verifying Chassis Cluster Control Plane Statistics

Purpose

Verify information about chassis cluster control plane statistics (heartbeats sent and received) and the
fabric link statistics (probes sent and received).
145

Action

From operational mode, enter the show chassis cluster control-plane statistics command.

{primary:node0}
user@host> show chassis cluster control-plane statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 2294
Heartbeat packets received: 2298
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 2290
Probes received: 615

Verifying Chassis Cluster Data Plane Statistics

Purpose

Verify information about the number of RTOs sent and received for services.

Action

From operational mode, enter the show chassis cluster data-plane statistics command.

{primary:node0}
user@host> show chassis cluster data-plane statistics

Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 6 0
Session create 161 0
Session close 148 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
146

Session ageout refresh replies 0 0


IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Verifying Chassis Cluster Redundancy Group Status

Purpose

Verify the state and priority of both nodes in a cluster and information about whether the primary node
has been preempted or whether there has been a manual failover.

Action

From operational mode, enter the chassis cluster status redundancy-group command.

{primary:node0}
user@host> show chassis cluster status redundancy-group 1
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 1, Failover count: 1


node0 100 primary no no
node1 50 secondary no no

Troubleshooting with Logs

Purpose

Use these logs to identify any chassis cluster issues. You should run these logs on both nodes.
147

Action

From operational mode, enter these show log commands.

user@host> show log jsrpd


user@host> show log chassisd
user@host> show log messages
user@host> show log dcd
user@host> show traceoptions

SEE ALSO

Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming | 18

Viewing a Chassis Cluster Configuration

IN THIS SECTION

Purpose | 147

Action | 147

Purpose

Display chassis cluster verification options.

Action

From the CLI, enter the show chassis cluster ? command:

{primary:node1}
user@host> show chassis cluster ?
Possible completions:
interfaces Display chassis-cluster interfaces
148

statistics Display chassis-cluster traffic statistics


status Display chassis-cluster status

Viewing Chassis Cluster Statistics

IN THIS SECTION

Purpose | 148

Action | 148

Purpose

Display information about chassis cluster services and interfaces.

Action

From the CLI, enter the show chassis cluster statistics command:

{primary:node1}
user@host> show chassis cluster statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 798
Heartbeat packets received: 784
Fabric link statistics:
Child link 0
Probes sent: 793
Probes received: 0
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
Session create 0 0
149

Session close 0 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RTSP ALG 0 0

{primary:node1}
user@host> show chassis cluster statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 258689
Heartbeat packets received: 258684
Control link 1:
Heartbeat packets sent: 258689
Heartbeat packets received: 258684
Fabric link statistics:
Child link 0
Probes sent: 258681
Probes received: 258681
Child link 1
Probes sent: 258501
Probes received: 258501
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
Session create 1 0
Session close 1 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
150

Session ageout refresh replies 0 0


IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

{primary:node1}
user@host> show chassis cluster statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 82371
Heartbeat packets received: 82321
Control link 1:
Heartbeat packets sent: 0
Heartbeat packets received: 0

Clearing Chassis Cluster Statistics

To clear displayed information about chassis cluster services and interfaces, enter the clear chassis
cluster statistics command from the CLI:

{primary:node1}
user@host> clear chassis cluster statistics

Cleared control-plane statistics


Cleared data-plane statistics
151

Understanding Automatic Chassis Cluster Synchronization Between


Primary and Secondary Nodes

When you set up an SRX Series chassis cluster, the SRX Series Firewalls must be identical, including
their configuration. The chassis cluster synchronization feature automatically synchronizes the
configuration from the primary node to the secondary node when the secondary joins the primary as a
cluster. By eliminating the manual work needed to ensure the same configurations on each node in the
cluster, this feature reduces expenses.

If you want to disable automatic chassis cluster synchronization between the primary and secondary
nodes, you can do so by entering the set chassis cluster configuration-synchronize no-secondary-bootup-auto
command in configuration mode.

At any time, to reenable automatic chassis cluster synchronization, use the delete chassis cluster
configuration-synchronize no-secondary-bootup-auto command in configuration mode.

To see whether the automatic chassis cluster synchronization is enabled or not, and to see the status of
the synchronization, enter the show chassis cluster information configuration-synchronization operational
command.

Either the entire configuration from the primary node is applied successfully to the secondary node, or
the secondary node retains its original configuration. There is no partial synchronization.

If you create a cluster with cluster IDs greater than 16, and then decide to roll back to a previous release
image that does not support extended cluster IDs, the system comes up as standalone.

If you have a cluster set up and running with an earlier release of Junos OS, you can upgrade to Junos
OS Release 12.1X45-D10 and re-create a cluster with cluster IDs greater than 16. However, if for any
reason you decide to revert to the previous version of Junos OS that did not support extended cluster
IDs, the system comes up with standalone devices after you reboot. However, if the cluster ID set is less
than 16 and you roll back to a previous release, the system will come back with the previous setup.

SEE ALSO

NTP Time Synchronization on SRX Series Devices | 360


152

Verifying Chassis Cluster Configuration Synchronization Status

IN THIS SECTION

Purpose | 152

Action | 152

Purpose

Display the configuration synchronization status of a chassis "Understanding Automatic Chassis Cluster
Synchronization Between Primary and Secondary Nodes" on page 151cluster.

Action

From the CLI, enter the show chassis cluster information configuration-synchronization command:

{primary:node0}
user@host> show chassis cluster information configuration-synchronization

node0:
--------------------------------------------------------------------------

Configuration Synchronization:
Status:
Activation status: Enabled
Last sync operation: Auto-Sync
Last sync result: Not needed
Last sync mgd messages:

Events:
Mar 5 01:48:53.662 : Auto-Sync: Not needed.

node1:
--------------------------------------------------------------------------

Configuration Synchronization:
Status:
153

Activation status: Enabled


Last sync operation: Auto-Sync
Last sync result: Succeeded
Last sync mgd messages:
mgd: rcp: /config/juniper.conf: No such file or directory
mgd: commit complete

Events:
Mar 5 01:48:55.339 : Auto-Sync: In progress. Attempt: 1
Mar 5 01:49:40.664 : Auto-Sync: Succeeded. Attempt: 1

SEE ALSO

show chassis cluster information configuration-synchronization | 803

RELATED DOCUMENTATION

Preparing Your Equipment for Chassis Cluster Formation | 31


Connecting SRX Series Firewalls to Create a Chassis Cluster | 34
SRX Series Chassis Cluster Configuration Overview | 13

Example: Enabling Eight-Queue Class of Service on


Redundant Ethernet Interfaces on SRX Series
Firewalls in a Chassis Cluster

IN THIS SECTION

Requirements | 154

Overview | 154

Configuration | 156

Verification | 164
154

This example shows how to enable eight-queue CoS on redundant Ethernet interfaces on SRX Series
Firewalls in a chassis cluster. This example is applicable to SRX5800, SRX5600, SRX5400, SRX4600,
SRX4200, and SRX4100. The eight-queue CoS is also supported on redundant Ethernet interfaces for
branch SRX Series Firewalls in a chassis cluster. The SRX Series for the branch support eight queues, but
only four queues are enabled by default.

Requirements

This example uses the following hardware and software components:

• Two SRX5600 Service Gateways in a chassis cluster

• Junos OS Release 11.4R4 or later for SRX Series Firewalls

Before you begin:

• Understand chassis cluster configuration. See "Example: Configuring an Active/Passive Chassis


Cluster on SRX5800 Devices" on page 369.

• Understand chassis cluster redundant interface configuration. See "Example: Configuring Chassis
Cluster Redundant Ethernet Interfaces" on page 103.

Overview

IN THIS SECTION

Topology | 155

The SRX Series Firewalls support eight queues, but only four queues are enabled by default. Use the set
chassis fpc x pic y max-queues-per-interface 8 command to enable eight queues explicitly at the chassis
level. The values of x and y depends on the location of the IOC and the PIC number where the interface
is located on the device on which CoS needs to be implemented. To find the IOC location use the show
chassis fpc pic-status or show chassis hardware commands.

You must restart the chassis control for the configuration to take effect.

On SRX Series Firewalls, eight QoS queues are supported per ae interface.
155

Figure 30 on page 155 shows how to configure eight-queue CoS on redundant Ethernet interfaces on
SRX Series Firewalls in a chassis cluster.

Topology

Figure 30: Eight-Queue CoS on Redundant Ethernet Interfaces


156

Configuration

IN THIS SECTION

Procedure | 156

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

set chassis fpc 5 pic 1 max-queues-per-interface 8


set chassis fpc 5 pic 1 max-queues-per-interface 8
set chassis cluster reth-count 2
set chassis cluster control-ports fpc 4 port 0
set chassis cluster control-ports fpc 10 port 0
set chassis cluster redundancy-group 0 node 0 priority 254
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 200
set chassis cluster redundancy-group 1 node 1 priority 100
set interfaces ge-5/1/14 gigether-options redundant-parent reth0
set interfaces ge-5/1/15 gigether-options redundant-parent reth1
set interfaces ge-11/1/14 gigether-options redundant-parent reth0
set interfaces ge-11/1/15 gigether-options redundant-parent reth1
set interfaces reth0 vlan-tagging
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 vlan-id 1350
set interfaces reth0 unit 0 family inet address 192.0.2.1/24
set interfaces reth1 hierarchical-scheduler
set interfaces reth1 vlan-tagging
set interfaces reth1 redundant-ether-options redundancy-group 2
set interfaces reth1 unit 0 vlan-id 1351
set interfaces reth1 unit 0 family inet address 192.0.2.2/24
set interfaces reth1 unit 1 vlan-id 1352
set interfaces reth1 unit 1 family inet address 192.0.2.3/24
157

set interfaces reth1 unit 2 vlan-id 1353


set interfaces reth1 unit 2 family inet address 192.0.2.4/24
set interfaces reth1 unit 3 vlan-id 1354
set interfaces reth1 unit 3 family inet address 192.0.2.5/24
set class-of-service classifiers inet-precedence inet_prec_4 forwarding-class q0 loss-priority
low code-points 000
set class-of-service classifiers inet-precedence inet_prec_4 forwarding-class q2 loss-priority
low code-points 010
set class-of-service classifiers inet-precedence inet_prec_4 forwarding-class q3 loss-priority
low code-points 011
set class-of-service classifiers inet-precedence inet_prec_4 forwarding-class q1 loss-priority
low code-points 001
set class-of-service classifiers inet-precedence inet_prec_4 forwarding-class q4 loss-priority
low code-points 100
set class-of-service classifiers inet-precedence inet_prec_4 forwarding-class q5 loss-priority
low code-points 101
set class-of-service classifiers inet-precedence inet_prec_4 forwarding-class q6 loss-priority
low code-points 110
set class-of-service classifiers inet-precedence inet_prec_4 forwarding-class q7 loss-priority
low code-points 111
set class-of-service forwarding-classes queue 0 q0
set class-of-service forwarding-classes queue 1 q1
set class-of-service forwarding-classes queue 2 q2
set class-of-service forwarding-classes queue 3 q3
set class-of-service forwarding-classes queue 4 q4
set class-of-service forwarding-classes queue 5 q5
set class-of-service forwarding-classes queue 6 q6
set class-of-service forwarding-classes queue 7 q7
set class-of-service traffic-control-profiles 1 scheduler-map sched_map
set class-of-service traffic-control-profiles 1 shaping-rate 200m
set class-of-service interfaces reth0 unit 0 classifiers inet-precedence inet_prec_4
set class-of-service interfaces reth1 unit 0 output-traffic-control-profile 1
set class-of-service scheduler-maps sched_map forwarding-class q0 scheduler S0
set class-of-service scheduler-maps sched_map forwarding-class q1 scheduler S1
set class-of-service scheduler-maps sched_map forwarding-class q2 scheduler S2
set class-of-service scheduler-maps sched_map forwarding-class q3 scheduler S3
set class-of-service scheduler-maps sched_map forwarding-class q4 scheduler S4
set class-of-service scheduler-maps sched_map forwarding-class q5 scheduler S5
set class-of-service scheduler-maps sched_map forwarding-class q6 scheduler S6
set class-of-service scheduler-maps sched_map forwarding-class q7 scheduler S7
set class-of-service schedulers S0 transmit-rate percent 20
set class-of-service schedulers S1 transmit-rate percent 5
set class-of-service schedulers S2 transmit-rate percent 5
158

set class-of-service schedulers S3 transmit-rate percent 10


set class-of-service schedulers S4 transmit-rate percent 10
set class-of-service schedulers S5 transmit-rate percent 10
set class-of-service schedulers S6 transmit-rate percent 10
set class-of-service schedulers S7 transmit-rate percent 30

Step-by-Step Procedure

The following example requires you to navigate various levels in the configuration hierarchy. For
instructions on how to do that, see Using the CLI Editor in Configuration Mode in the CLI User Guide.

To enable eight-queue CoS on redundant Ethernet interfaces:

1. Configure a maximum of eight queues on the interfaces on Node 0 and Node 1.

[edit chassis]
user@host# set fpc 5 pic 1 max-queues-per-interface 8

In addition to configuring eight queues at the [edit chassis] hierarchy level, the configuration at the
[edit class-of-service] hierarchy level must support eight queues per interface.

2. Specify the number of redundant Ethernet interfaces.

[edit chassis cluster]


user@host# set reth-count 2

3. Configure the control ports.

[edit chassis cluster]


user@host# set control-ports fpc 4 port 0
user@host# set control-ports fpc 10 port 0

4. Configure redundancy groups.

[edit chassis cluster]


user@host# set redundancy-group 0 node 0 priority 254
user@host# set redundancy-group 0 node 1 priority 1
user@host# set redundancy-group 1 node 0 priority 200
user@host# set redundancy-group 1 node 1 priority 100
159

5. Configure the redundant Ethernet interfaces.

[edit interfaces]
user@host# set ge-5/1/14 gigether-options redundant-parent reth0
user@host# set ge-11/1/14 gigether-options redundant-parent reth0
user@host# set ge-5/1/15 gigether-options redundant-parent reth1
user@host# set ge-11/1/15 gigether-options redundant-parent reth1
user@host# set reth0 redundant-ether-options redundancy-group 1
user@host# set reth0 vlan-tagging
user@host# set reth0 unit 0 vlan-id 1350
user@host# set reth0 unit 0 family inet address 192.0.2.1/24
user@host# set reth1 hierarchical-scheduler
user@host# set reth1 vlan-tagging
user@host# set reth1 redundant-ether-options redundancy-group 2
user@host# set reth1 unit 0 vlan-id 1351
user@host# set reth1 unit 0 family inet address 192.0.2.2/24
user@host# set reth1 unit 1 vlan-id 1352
user@host# set reth1 unit 1 family inet address 192.0.2.3/24
user@host# set reth1 unit 2 vlan-id 1353
user@host# set reth1 unit 2 family inet address 192.0.2.4/24
user@host# set reth1 unit 3 vlan-id 1354
user@host# set reth1 unit 3 family inet address 192.0.2.5/24

6. Define a classifier and apply it to a logical interface.

[edit class-of-service]
user@host# set classifiers inet-precedence inet_prec_4 forwarding-class q0 loss-priority
low code-points 000
user@host# set classifiers inet-precedence inet_prec_4 forwarding-class q2 loss-priority
low code-points 010
user@host# set classifiers inet-precedence inet_prec_4 forwarding-class q3 loss-priority
low code-points 011
user@host# set classifiers inet-precedence inet_prec_4 forwarding-class q1 loss-priority
low code-points 001
user@host# set classifiers inet-precedence inet_prec_4 forwarding-class q4 loss-priority
low code-points 100
user@host# set classifiers inet-precedence inet_prec_4 forwarding-class q5 loss-priority
low code-points 101
user@host# set classifiers inet-precedence inet_prec_4 forwarding-class q6 loss-priority
low code-points 110
160

user@host# set classifiers inet-precedence inet_prec_4 forwarding-class q7 loss-priority


low code-points 111

7. Map forwarding classes to CoS queues.

[edit class-of-service]
user@host# set forwarding-classes queue 0 q0
user@host# set forwarding-classes queue 1 q1
user@host# set forwarding-classes queue 2 q2
user@host# set forwarding-classes queue 3 q3
user@host# set forwarding-classes queue 4 q4
user@host# set forwarding-classes queue 5 q5
user@host# set forwarding-classes queue 6 q6
user@host# set forwarding-classes queue 7 q7

8. Configure traffic control profiles.

[edit class-of-service]
user@host# set traffic-control-profiles 1 scheduler-map sched_map
user@host# set traffic-control-profiles 1 shaping-rate 200m

9. Define packet flow through the CoS elements.

[edit class-of-service]
user@host# set interfaces reth0 unit 0 classifiers inet-precedence inet_prec_4

10. Apply a traffic scheduling profile to the interface.

[edit class-of-service]
user@host# set interfaces reth1 unit 0 output-traffic-control-profile 1

11. Configure the CoS schedulers.

[edit class-of-service]
user@host# set scheduler-maps sched_map forwarding-class q0 scheduler S0
user@host# set scheduler-maps sched_map forwarding-class q1 scheduler S1
user@host# set scheduler-maps sched_map forwarding-class q2 scheduler S2
user@host# set scheduler-maps sched_map forwarding-class q3 scheduler S3
161

user@host# set scheduler-maps sched_map forwarding-class q4 scheduler S4


user@host# set scheduler-maps sched_map forwarding-class q5 scheduler S5
user@host# set scheduler-maps sched_map forwarding-class q6 scheduler S6
user@host# set scheduler-maps sched_map forwarding-class q7 scheduler S7
user@host# set schedulers S0 transmit-rate percent 20
user@host# set schedulers S1 transmit-rate percent 5
user@host# set schedulers S2 transmit-rate percent 5
user@host# set schedulers S3 transmit-rate percent 10
user@host# set schedulers S4 transmit-rate percent 10
user@host# set schedulers S5 transmit-rate percent 10
user@host# set schedulers S6 transmit-rate percent 10
user@host# set schedulers S7 transmit-rate percent 30

Results

From configuration mode, confirm your configuration by entering the show class-of-service command. If
the output does not display the intended configuration, repeat the configuration instructions in this
example to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

[edit]
user@host# show class-of-service
classifiers {
inet-precedence inet_prec_4 {
forwarding-class q0 {
loss-priority low code-points 000;
}
forwarding-class q2 {
loss-priority low code-points 010;
}
forwarding-class q3 {
loss-priority low code-points 011;
}
forwarding-class q1 {
loss-priority low code-points 001;
}
forwarding-class q4 {
loss-priority low code-points 100;
}
forwarding-class q5 {
162

loss-priority low code-points 101;


}
forwarding-class q6 {
loss-priority low code-points 110;
}
forwarding-class q7 {
loss-priority low code-points 111;
}
}
}
forwarding-classes {
queue 0 q0;
queue 1 q1;
queue 2 q2;
queue 3 q3;
queue 4 q4;
queue 5 q5;
queue 6 q6;
queue 7 q7;
}
traffic-control-profiles {
1 {
scheduler-map sched_map;
shaping-rate 200m;
}
}
interfaces {
reth0 {
unit 0 {
classifiers {
inet-precedence inet_prec_4;
}
}
}
reth1 {
unit 0 {
output-traffic-control-profile 1;
}
}
}
scheduler-maps {
sched_map {
forwarding-class q0 scheduler S0;
163

forwarding-class q1 scheduler S1;


forwarding-class q2 scheduler S2;
forwarding-class q3 scheduler S3;
forwarding-class q4 scheduler S4;
forwarding-class q5 scheduler S5;
forwarding-class q6 scheduler S6;
forwarding-class q7 scheduler S7;
}
}
schedulers {
S0 {
transmit-rate percent 20;
}
S1 {
transmit-rate percent 5;
}
S2 {
transmit-rate percent 5;
}
S3 {
transmit-rate percent 10;
}
S4 {
transmit-rate percent 10;
}
S5 {
transmit-rate percent 10;
}
S6 {
transmit-rate percent 10;
}
S7 {
transmit-rate percent 30;
}
}

If you are done configuring the device, enter commit from configuration mode.

To restart chassis control, enter restart chassis-control command from operational mode.

When you execute the restart chassis-control command all the FRU cards on the box are reset, thus
impacting traffic. Changing the number of queues must be executed during a scheduled downtime. It
takes 5-10 minutes for the cards to come online after the restart chassis-control command is executed.
164

Verification

IN THIS SECTION

Verifying the Eight-Queue COS Configuration | 164

Verifying the Eight-Queue COS Configuration

Purpose

Verify that eight-queue CoS is enabled properly.

Action

From the operational mode, enter the following commands:

• show interfaces ge-5/1/14 extensive

• show interfaces queue ge-5/1/14

• show class-of-service forwarding-class

• show class-of-service interface ge-5/1/14

RELATED DOCUMENTATION

SRX Series Chassis Cluster Configuration Overview | 13


Chassis Cluster Redundant Ethernet Interfaces | 99
165

Conditional Route Advertisement over Redundant


Ethernet Interfaces on SRX Series Firewalls in a
Chassis Cluster

IN THIS SECTION

Understanding Conditional Route Advertising in a Chassis Cluster | 165

Example: Configuring Conditional Route Advertising in a Chassis Cluster | 166

Conditional route advertising allows you to add criteria on route advertisements before they are
installed in the route table or advertised to peers and neighbors. The goal of conditional route
advertisement in a chassis cluster is to ensure that incoming traffic from the upstream network arrives
on the node that is on the currently active redundant Ethernet interface. For more information, see the
following topics:

Understanding Conditional Route Advertising in a Chassis Cluster

Route advertisement over redundant Ethernet interfaces in a chassis cluster is complicated by the fact
that the active node in the cluster can change dynamically. Conditional route advertisement enables you
to advertise routes in such a way that incoming traffic from the core network is attracted to the Border
Gateway Protocol (BGP) interface that exists on the same node as the currently active redundant
Ethernet interface. In this way, traffic is processed by the active node and does not traverse the fabric
interface between nodes. You do this by manipulating the BGP attribute at the time routes are
advertised by BGP.

The goal of conditional route advertisement in a chassis cluster is to ensure that incoming traffic from
the upstream network arrives on the node that is on the currently active redundant Ethernet interface.
To understand how this works, keep in mind that in a chassis cluster, each node has its own set of
interfaces.

SEE ALSO

Example: Configuring Conditional Route Advertising in a Chassis Cluster | 166


166

Viewing a Chassis Cluster Configuration | 147


Viewing Chassis Cluster Statistics | 148

Example: Configuring Conditional Route Advertising in a Chassis Cluster

IN THIS SECTION

Requirements | 166

Overview | 166

Configuration | 168

This example shows how to configure conditional route advertising in a chassis cluster to ensure that
incoming traffic from the upstream network arrives on the node that is on the currently active
redundant Ethernet interface.

Requirements
Before you begin, understand conditional route advertising in a chassis cluster. See "Understanding
Conditional Route Advertising in a Chassis Cluster" on page 165.

Overview
As illustrated in Figure 31 on page 167, routing prefixes learned from the redundant Ethernet interface
through the IGP are advertised toward the network core using BGP. Two BGP sessions are maintained,
one from interface ge-0/0/0 and one from ge-1/0/0 for BGP multihoming. All routing prefixes are
advertised on both sessions. Thus, for a route advertised by BGP, learned over a redundant Ethernet
interface, if the active redundant Ethernet interface is on the same node as the BGP session, you
advertise the route with a “good” BGP attribute.
167

Figure 31: Conditional Route Advertising on SRX Series Firewalls in a Chassis Cluster

To achieve this behavior, you apply a policy to BGP before exporting routes. An additional term in the
policy match condition determines the current active redundant Ethernet interface child interface of the
next hop before making the routing decision. When the active status of a child redundant Ethernet
interface changes, BGP reevaluates the export policy for all routes affected.

The condition statement in this configuration works as follows. The command states that any routes
evaluated against this condition will pass only if:

• The routes have a redundant Ethernet interface as their next-hop interface.


168

• The current child interface of the redundant Ethernet interface is active at node 0 (as specified by the
route-active-on node0 keyword).

{primary:node0}[edit]
user@host# set policy-options condition reth-nh-active-on-0 route-active-on node0

Note that a route might have multiple equal-cost next hops, and those next hops might be redundant
Ethernet interfaces, regular interfaces, or a combination of both. The route still satisfies the requirement
that it has a redundant Ethernet interface as its next hop.

If you use the BGP export policy set for node 0 in the previous example command, only OSPF routes
that satisfy the following requirements will be advertised through the session:

• The OSPF routes have a redundant Ethernet interface as their next hop.

• The current child interface of the redundant Ethernet interface is currently active at node 0.

You must also create and apply a separate policy statement for the other BGP session by using this same
process.

In addition to the BGP MED attribute, you can define additional BGP attributes, such as origin-code, as-
path, and community.

Configuration

IN THIS SECTION

Procedure | 168

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set policy-options policy-statement reth-nh-active-on-0 term ospf-on-0 from protocol ospf
set policy-options policy-statement reth-nh-active-on-0 term ospf-on-0 from condition reth-nh-
169

active-on-0
set policy-options policy-statement reth-nh-active-on-0 term ospf-on-0 then metric 10
set policy-options policy-statement reth-nh-active-on-0 term ospf-on-0 then accept
set policy-options condition reth-nh-active-on-0 route-active-on node0

Step-by-Step Procedure

To configure conditional route advertising:

• Create the export policies with the created condition using the condition statement.

{primary:node0}[edit]
user@host# set policy-options policy-statement reth-nh-active-on-0 term ospf-on-0 from
protocol ospf
{primary:node0}[edit]
user@host# set policy-options policy-statement reth-nh-active-on-0 term ospf-on-0 from
condition reth-nh-active-on-0
{primary:node0}[edit]
user@host# set policy-options policy-statement reth-nh-active-on-0 term ospf-on-0 then metric
10
{primary:node0}[edit]
user@host# set policy-options policy-statement reth-nh-active-on-0 term ospf-on-0 then accept
{primary:node0}[edit]
user@host# set policy-options condition reth-nh-active-on-0 route-active-on node0

Results

From configuration mode, confirm your configuration by entering the show policy-options command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

{primary:node0}[edit]
user@host# show policy-options
policy-statement reth-nh-active-on-0 {
term ospf-on-0 {
from {
protocol ospf;
condition reth-nh-active-on-0;
}
170

then {
metric 10;
accept;
}
}
}
condition reth-nh-active-on-0 route-active-on node0;

If you are done configuring the device, enter commit from configuration mode.

SEE ALSO

Understanding Conditional Route Advertising in a Chassis Cluster | 165


Viewing a Chassis Cluster Configuration | 147
Viewing Chassis Cluster Statistics | 148
3 CHAPTER

Configuring Redundancy and Failover


in a Chassis Cluster

Chassis Cluster Dual Control Links | 172

Chassis Cluster Dual Fabric Links | 201

Monitoring of Global-Level Objects in a Chassis Cluster | 209

Monitoring Chassis Cluster Interfaces | 214

Monitoring IP Addresses on a Chassis Cluster | 255

Configuring Cluster Failover Parameters | 276

Understanding Chassis Cluster Resiliency | 281

Chassis Cluster Redundancy Group Failover | 282


172

Chassis Cluster Dual Control Links

IN THIS SECTION

Chassis Cluster Dual Control Links Overview | 172

Dual Control Link Connections for SRX Series Firewalls in a Chassis Cluster | 174

Upgrade the Second Routing Engine When Using Chassis Cluster Dual Control Links on SRX5600 and
SRX5800 Devices | 176

Example: Configure Chassis Cluster Control Ports for Dual Control Links | 178

Resiliency with SCB Dual Control Links | 181

Example: Configure a Chassis Cluster Using SCB Dual Control Links | 184

Transition from SPC Dual Control Links to SCB Dual Control Links | 190

Transition from SCB to SPC with Dual Control Links | 196

Dual control links provide a redundant link for controlling network traffic.

Chassis Cluster Dual Control Links Overview

IN THIS SECTION

Benefit of Dual Control Links | 173

Dual Control Link Functionality Requirements | 173

A control link connects two SRX Series Firewalls and sends chassis cluster control data, including
heartbeats and configuration synchronization, between them. The link is a single point of failure: If the
control link goes down, the secondary SRX Series is disabled from the cluster.

Dual control links prevent downtime due to a single point of failure. Two control link interfaces connect
each device in a cluster. Dual control links provide a redundant link for controlling traffic. Unlike dual
fabric links, only one control link is used at any one time.
173

The SRX4600, SRX5600, and SRX5800 Services Gateways support dual control links.

We do not support dual control link functionality on these Services Gateways: SRX4100, SRX4200, or
SRX5400.

Starting with Junos OS Release 20.4R1, you can enable or disable the control links on SRX1500 Services
Gateways using operational mode CLI commands and configuration mode CLI commands, described in a
subsequent paragraph. This CLI feature enables you to control the status of cluster nodes during a
cluster upgrade.

Previously, if you wanted to disable the control link and fabric link, you had to unplug the cables
manually.

The CLI commands work as follows:

• In configuration mode

• To disable the control link, run the set chassis cluster control-interface <node0/node1> disable on node
0 or node 1.

If you disable the links using the configuration command, the links remain disabled even after
system reboot.

• To enable the control link, run the delete chassis cluster control-interface <node0/node1> disable on
both nodes.

• In operational mode

• To disable the control link from the local node, run the request chassis cluster control-interface
<node0/node1> disable command.

If you disable the control link using the operational mode CLI command, the link will be enabled
after system reboot.

• To enable the control link on a local node, run the request chassis cluster control-interface <node0/
node1> enable command.

Benefit of Dual Control Links

Dual control links prevent the possibility of a single point of failure by providing a redundant link for
control traffic.

Dual Control Link Functionality Requirements

For the SRX5600 and SRX5800 Services Gateways, dual control link functionality requires that a second
Routing Engine and a second Switch Control Board (SCB) be installed on each device in the cluster. The
174

purpose of the second Routing Engine is to initialize the switch on the primary SCB. The second SCB
houses the second Routing Engine.

For the SRX5000 Services Gateways only, the second Routing Engine must be running Junos OS Release
10.0 or later.

This second Routing Engine does not provide backup functionality. It does not need to be upgraded,
even when you upgrade the software on the primary Routing Engine on the same node. Note the
following conditions:

• You can run CLI commands and enter configuration mode only on the primary Routing Engine.

• You set the chassis ID and cluster ID only on the primary Routing Engine.

• If you want to be able to check that the second Routing Engine boots up, or if you want to upgrade a
software image, you need a console connection to the second Routing Engine.

As long as the first Routing Engine is installed (even if it reboots or fails), the second Routing Engine
cannot take over the chassis primary role; that is, it cannot control any of the hardware on the chassis.

A redundancy group 0 failover implies a Routing Engine failover. In the case of a Routing Engine failover,
all processes running on the primary node are killed and then spawned on the new primary Routing
Engine. This failover could result in loss of state, such as routing state, and degrade performance by
introducing system churn.

For SRX3000 Services Gateways, dual control link functionality requires that an SRX Clustering Module
(SCM) be installed on each device in the cluster. Although the SCM fits in the Routing Engine slot, it is
not a Routing Engine. The SRX3000 devices do not support a second Routing Engine. The purpose of
the SCM is only to initialize the second control link.

SEE ALSO

Chassis Cluster Control Plane Interfaces | 67

Dual Control Link Connections for SRX Series Firewalls in a Chassis


Cluster

You can connect two control links between SRX5600 devices and SRX5800 devices, effectively reducing
the chance of control link failure.
175

NOTE: Junos OS does not support dual control links on SRX5400 devices, due to the limited
number of slots.

For SRX5600 devices and SRX5800 devices, connect two pairs of the same type of Ethernet ports. For
each device, you can use ports on the same Services Processing Card (SPC), but we recommend that you
connect the control ports to two different SPCs to provide high availability. Figure 32 on page 175
shows a pair of SRX5800 devices with dual control links connected. In this example, control port 0 and
control port 1 are connected on different SPCs.

Figure 32: Dual Control Link Connections (SRX5800 Devices)

For SRX5600 devices and SRX5800 devices, you must connect control port 0 on one node to control
port 0 on the other node. You must also connect control port 1 on one node to control port 1 on the
other node. If you connect control port 0 to control port 1, the nodes cannot receive heartbeat packets
across the control links.

SEE ALSO

Connecting SRX Series Firewalls to Create a Chassis Cluster | 34


Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming | 18
scb-control-ports | 709
request chassis fpc-control-port | 755
request chassis primary-ha-control-port-transition | 759
176

Upgrade the Second Routing Engine When Using Chassis Cluster Dual
Control Links on SRX5600 and SRX5800 Devices

You must use a second Routing Engine for each SRX5600 device and SRX5800 device in a cluster if you
are using dual control links. The second Routing Engine does not provide backup functionality; its
purpose is only to initialize the switch on the Switch Control Board (SCB). The second Routing Engine
must be running Junos OS Release 12.1X47-D35, 12.3X48-D30, 15.1X49-D40, or later. For more
information, see knowledge base article KB30371.

On SRX5600 devices and SRX5800 devices, you can use the show chassis hardware command to see the
serial number and the hardware version details of the second Routing Engine. To use this functionality,
ensure that the second Routing Engine is running either Junos OS Release 15.1X49-D70 or Junos OS
Release 17.3R1.

Junos OS does not support dual control link functionality on the SRX5400 Services Gateways, due to
limited slots.

Instead, use the primary Routing Engine to create a bootable USB storage device, which you can then
use to install a software image on the second Routing Engine.

To upgrade the software image on the second Routing Engine:

1. Use FTP to copy the installation media into the /var/tmp directory of the primary Routing Engine.
2. Insert a USB storage device into the USB port on the primary Routing Engine.
3. In the UNIX shell, navigate to the /var/tmp directory:

start shell
cd /var/tmp

4. Log in as root or superuser:

su [enter]
password: [enter SU password]

5. Issue the following command:

dd if=installMedia of=/dev/externalDrive bs=1m

where

• externalDrive—Refers to the removable media name. For example, the removable media name on
an SRX5000 line device is da0 for both Routing Engines.
177

• installMedia—Refers to the installation media downloaded into the /var/tmp directory. For
example, junos-install-media-usb-srx5000-x86-64-21.4R1.7.img.gz.

Copy the install-media image to the primary Routing Engine in step 1 onto the USB storage device:

dd if=junos-install-media-usb-srx5000-x86-64-21.4R1.7.img.gz of=/dev/da0 bs=1m

6. Log out as root or superuser:

exit

7. After the software image is written to the USB storage device, remove the device and insert it into
the USB port on the second Routing Engine.
8. Move the console connection from the primary Routing Engine to the second Routing Engine, if you
do not already have a connection.
9. Reboot the second Routing Engine. Issue the following command (for Junos OS Release 15.1X49-
D65 and earlier):

# reboot

Starting with Junos OS Release 15.1X49-D70, issue the following command:

login : root

root % reboot

• When the following system output appears, press y:

WARNING: The installation will erase the contents of your disks.


Do you wish to continue (y/n)?

• When the following system output appears, remove the USB storage device and press Enter:

Eject the installation media and hit [Enter] to reboot?


178

Example: Configure Chassis Cluster Control Ports for Dual Control Links

IN THIS SECTION

Requirements | 178

Overview | 178

Configuration | 179

Verification | 180

This example shows how to configure chassis cluster control ports for use as dual control links on
SRX5600 devices and SRX5800 devices. You need to configure the control ports that you will use on
each device to set up the control links.

Junos OS does not support dual control links on SRX5400 devices, due to the limited number of slots.

Requirements
Before you begin:

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

• Physically connect the control ports on the devices. See "Connecting SRX Series Devices to Create a
Chassis Cluster" on page 34.

Overview
By default, all control ports on SRX5600 devices and SRX5800 devices are disabled. After connecting
the control ports, configuring the control ports, and establishing the chassis cluster, the control links are
set up.

This example configures control ports with the following FPCs and ports as the dual control links:

• FPC 4, port 0

• FPC 10, port 0

• FPC 6, port 1

• FPC 12, port 1


179

Configuration

IN THIS SECTION

Procedure | 179

Procedure

CLI Quick Configuration

To quickly configure this section of the example, copy the following commands, paste them into a text
file, remove any line breaks, change any details necessary to match your network configuration, copy
and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from
configuration mode.

{primary:node0}[edit]
set chassis cluster control-ports fpc 4 port 0
set chassis cluster control-ports fpc 10 port 0
set chassis cluster control-ports fpc 6 port 1
set chassis cluster control-ports fpc 12 port 1

Step-by-Step Procedure

To configure control ports for use as dual control links for the chassis cluster:

Specify the control ports.

{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 4 port 0
{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 10 port 0
{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 6 port 1
{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 12 port 1
180

Results

In configuration mode, confirm your configuration by entering the show chassis cluster command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

{primary:node0}[edit]
user@host# show chassis cluster
...
control-ports {
fpc 4 port 0;
fpc 6 port 1;
fpc 10 port 0;
fpc 12 port 1;
}
...

If you are finished configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verification of the Chassis Cluster Status | 180

Verification of the Chassis Cluster Status

Purpose

Verify the chassis cluster status.


181

Action

In operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 100 primary no no
node1 1 secondary no no

Redundancy group: 1 , Failover count: 1


node0 0 primary no no
node1 0 secondary no no

Meaning

Use the show chassis cluster status command to confirm that the devices in the chassis cluster are
communicating with each other. The output shows that the chassis cluster is functioning properly, as
one device is the primary node and the other is the secondary node.

Resiliency with SCB Dual Control Links

On SRX5600 devices and SRX5800 devices, a Switch Control Board (SCB) card adds 10-Gigabit
Ethernet (GbE) Small form-factor pluggables ports (SFPP) ports to provide redundancy. In a chassis
cluster setup, you can configure these Ethernet ports as chassis cluster control ports to provide dual
control links.

Dual control links help prevent a single point of failure by offering a redundant link for control traffic.

On SCB3 and SCB4, there are two external 10 Gbe ethernet ports located in the front panel. The left
port (SCB Ethernet-switch port xe0) is used as the SCB HA port.

For SRX5600 devices and SRX5800 devices operating in chassis cluster, you can configure 10 Gigabit
Ethernet ports on the SCB front panels to operate as chassis cluster control ports using Long Reach (LR),
Short Reach (SR), and Long Reach Multimode (LRM) interfaces.

You can use the following 10GbE SFPP ports as chassis cluster control ports:
182

Table 16: SCB External 10GbE Ports

SCB SFPP Ports

SCB2 SFPP-10GbE-LR

SFPP-10GbE-SR

SFPP-10GbE-LRM

SCB3 and SCB4 SFPP-10GbE-LR

SFPP-10GbE-SR

For SRX Series Firewalls operating in chassis cluster, you can configure Ethernet ports on the SCB front
panels to operate as chassis cluster control ports.

NOTE: SRX5400 Services Gateways do not support dual control links, due to limited slots. These
devices supports only chassis cluster control port 0.

Benefits of SCB Dual Control Links:

• Increase the resiliency of the chassis cluster.

• Maintain reliability of the chassis cluster in the event of an SPC failure.

Figure 33 on page 183 shows a chassis cluster using SCB dual control links. The term HA used in the
Figure 33 on page 183 and Table 17 on page 183 is referred to as chassis cluster.
183

Figure 33: SCB Dual Control Links in a Chassis Cluster

The control port connections on the chassis cluster are as follows:

Table 17: Control Port Connections

Primary Control Link Secondary Control Link

SCB0 is Control Board 0. HA port 0 is on SCB0. SCB1 is Control Board 1. HA port 1 is on SCB1.

Routing Engine 0 is on SCB0. Routing Engine 1 is on SCB1.

The Ethernet port on SCB0 is used as HA port 0. The Ethernet port on SCB1 is used as HA port 1.

The control packets pass through the SCB control links instead of the SPC control links.

SEE ALSO

request chassis primary-ha-control-port-transition | 759


request chassis fpc-control-port | 755
scb-control-ports | 709
184

Example: Configure a Chassis Cluster Using SCB Dual Control Links

IN THIS SECTION

Requirements | 184

Overview | 184

Configuration | 186

Verification | 187

This example shows how to configure SCB dual control links on a chassis cluster.

In standalone mode, you must configure SCB dual control links and reboot the nodes to activate the
changes.

Requirements
Before you begin:

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

• To support dual control links on SCB ports, upgrade both primary Routing Engine (RE0) and
secondary Routing Engine (RE1) software to Junos OS 21.4R1 or later. For more information, see "
Upgrading the Second Routing Engine" on page 176 and Install Software on SRX.

Overview
To configure dual control links in a chassis cluster, you connect primary and secondary control links
between the SCB chassis cluster control ports as shown in Figure 33 on page 183.

SCB control links have below properties:

1. For RE0, SCB0 chassis cluster control port is automatically enabled when system boots in chassis
cluster mode.
SCB0 chassis cluster control port is automatically disabled when system boots in standalone mode.

2. For RE1, SCB1 chassis cluster control port is automatically enabled after reboot, irrespective of
whether the device is in chassis cluster mode or standalone mode.
185

3. To temporary disable primary SCB contol link in chassis cluster mode, disable the SCB0 control port
on RE0:

user@host> test chassis ethernet-switch shell-cmd "port xe0 enable=0"

To temporary disable secondary SCB control link, disable the SCB 1 control port on RE1:

user@host> test chassis ethernet-switch shell-cmd "port xe0 enable=0"

NOTE: These CLI commands will lose effect after redundancy group 0 failover or device
reboot.

4. To permanently disable primary SCB control link in chassis cluster mode:

• Option1: Delete the SCB control port configurations, add fake FPC control link configurations,
and commit.

• Option2: Disconnect the primary SCB control link cable.

5. To permanently disable secondary SCB control link in chassis cluster mode, disconnect the secondary
SCB control link cable.

6. To change from cluster mode to standalone mode when using dual SCB control links:

NOTE: Below steps are for temporary transition from cluster to standalone. If you need to
change to standalone mode permanently, disconnect both the primary and secondary SCB
control link cables.

a. Disable SCB1 HA control ports on both nodes through RE1:

user@host> test chassis ethernet-switch shell-cmd "port xe0 enable=0"

user@host> test chassis ethernet-switch shell-cmd ps | grep xe0

xe0 !ena 10G FD SW No Forward TX RX None FA XGMII 16356


186

b. Reboot the RE0 to set as standalone mode:

user@host> set chassis cluster disable reboot

c. To enter the cluster mode again, enable the cluster mode on RE0 and reboot and then enable
SCB1 HA control ports on both nodes through RE1 console:

user@host> test chassis ethernet-switch shell-cmd "port xe0 enable=1"

user@host> test chassis ethernet-switch shell-cmd ps | grep xe0

xe0 up 10G FD SW No Forward TX RX None FA XGMII 16356

d. Check the chassis cluster status.

Configuration

IN THIS SECTION

Procedure | 186

Procedure

To configure SCB dual control links for the chassis cluster:

1. Connect the primary SCB control link cable.

2. Configure a chassis cluster that uses SCB0 control port for primary control link and SCB1 control port
for secondary control link on both nodes.

[edit]
user@host# set chassis cluster scb-control-ports 0
user@host# set chassis cluster scb-control-ports 1
187

3. Configure the chassis cluster. The example configuration is for node 0. For node 1, make sure to
configure the same cluster ID.

[edit]
user@host> set chassis cluster cluster-id 1 node 0

4. Reboot both nodes to activate cluster mode.

5. Connect the secondary SCB control link cable.

Verification

IN THIS SECTION

Verification of the Chassis Cluster Status | 187

Verification of the Chassis Cluster Status

Purpose

Verify the chassis cluster status.

Action

In operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring RE Relinquish monitoring
IS IRQ storm
188

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 1


node0 200 primary no no None
node1 199 secondary no no None

In operational mode, enter the show chassis cluster interfaces command.

user@host> show chassis cluster interfaces


Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 ixlv0 Up Disabled Disabled
1 igb0 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-3/0/7 Up / Up Disabled
fab0
fab1 xe-15/0/7 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0
189

In operational mode, enter the show chassis cluster information detail command.

user@host> show chassis cluster information detail


node0:
--------------------------------------------------------------------------
Redundancy mode:
Configured mode: active-active
Operational mode: active-active
Cluster configuration:
Heartbeat interval: 2000 ms
Heartbeat threshold: 8
Control link recovery: Disabled
Fabric link down timeout: 352 sec
Node health information:
Local node health: Healthy
Remote node health: Healthy

Redundancy group: 0, Threshold: 255, Monitoring failures: none


Events:
May 6 17:38:01.665 : hold->secondary, reason: Hold timer expired

Redundancy group: 1, Threshold: 255, Monitoring failures: none


Events:
May 6 17:38:01.666 : hold->secondary, reason: Hold timer expired
Control link statistics:
Control link 0:
Heartbeat packets sent: 205193
Heartbeat packets received: 205171
Heartbeat packet errors: 0
Node 0 SCB HA port TX FCS Errors: 0
Node 0 SCB HA port RX FCS Errors: 0
Node 1 SCB HA port TX FCS Errors: 0
Node 1 SCB HA port RX FCS Errors: 0
Duplicate heartbeat packets received: 361
Control link 1:
Heartbeat packets sent: 707
Heartbeat packets received: 697
Heartbeat packet errors: 0
Node 0 SCB HA port TX FCS Errors: NA
Node 0 SCB HA port RX FCS Errors: NA
Node 1 SCB HA port TX FCS Errors: NA
190

Node 1 SCB HA port RX FCS Errors: NA


Duplicate heartbeat packets received: 329

In operational mode, enter the show chassis cluster fpc pic-status command.

user@host> show chassis cluster fpc pic-status


node0:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

node1:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

Meaning

Use the show chassis cluster command to confirm that the devices in the chassis cluster are
communicating with each other and functioning properly.

Transition from SPC Dual Control Links to SCB Dual Control Links

IN THIS SECTION

Requirements | 191

Overview | 191
191

Transition Procedure: SPC to SCB with Dual Control Links | 192

This example shows how to transition SPC dual control links to SCB dual control links. This procedure
minimizes traffic disruption and prevents control plane loops during the control link transition.

Requirements
Before you begin:

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

• Learn how to physically connect both SPC control ports and SCB control ports. In this procedure, you
must remove cables from and attach cables to both SPC and SCB cards. See "Connecting SRX Series
Devices to Create a Chassis Cluster" on page 34.

Overview
In this example, you begin with a working chassis cluster that uses SPC dual control links. The goal is to
transition the system to use SCB control links seamlessly. To prevent the formation of a control plane
loop, the system must not actively forward over the two different control links at the same time.

Two combinations of simultaneous SPC and SCB control link connections ensure loop-free operation. As
part of your transition strategy, you must decide on one of the following control link combinations:

• SPC as the primary control link with SCB as the secondary control link

• SCB as the primary control link with SPC as the secondary control link

The transition modes support both the combinations of simultaneous SPC and SCB control links to
ensure that only one type of control links is forwarding. If both SPC and SCB control links are active at
the same time, a loop can form.

Either supported option (SPC or SCB) works as well as the other. This example illustrates the first
option. During the control link transition, the primary SPC control link remains active while you add a
secondary SCB control link. Again, this state is transitory. After the transition, you have a chassis cluster
with both the primary and secondary control links connected to the SCB port.

Control Links illustrates the process for transitioning from SPC control links to SCB control links.
192

Figure 34: Control Links Transition Stages

The starting state of the chassis cluster before transition is displayed on the top. Two SPC control ports
are used to form the cluster. In the middle, the transition state has one SPC control port and one SCB
control port simultaneously connected. After transition, the ending state of the chassis cluster is
displayed to the bottom. The chassis cluster operates with two SCB control links after removing the
original SPC control links.

Transition Procedure: SPC to SCB with Dual Control Links

IN THIS SECTION

Procedure | 192

Procedure

To transition from SPC to SCB dual control links on the primary node (node 0):
193

1. Select the preferred transition approach. Refer to "Transition Options" on page 191. In this
example, select the primary SPC link with a secondary SCB link as shown in Control Links.

2. Delete the SPC secondary control link configuration. This configuration change deletes both ends
of the secondary SPC control links in the chassis cluster.

{primary:node0}[edit]
user@host# delete chassis cluster control-ports fpc 2 port 1
user@host# delete chassis cluster control-ports fpc 14 port 1
user@host# commit

3. Disconnect the SPC secondary control link cable before proceeding.

4. Configure the SCB secondary control link and commit. The same SCB1 control port is used at both
ends of the cluster. This single configuration statement applies to both node 0 and node 1.

{primary:node0}[edit]
user@host# set chassis cluster scb-control-ports 1
user@host# commit

5. Connect the SCB secondary control link cable. At this time, the chassis cluster is in a transitional
state.

6. Before continuing the transition, you verify that the chassis cluster is operational and that the dual
control links are in a healthy state. Use the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 ixlv0 Up Disabled Disabled
1 igb0 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-3/0/7 Up / Up Disabled
194

fab0
fab1 xe-15/0/7 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

In the preceding output, the ixlv0 and igb0 interfaces are used to send cluster control traffic and
keepalive traffic.

{primary:node0}
user@host> show chassis fpc pic-status
node0:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

node1:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

The chassis cluster control link reports up status. The remote node's cards (SPC and PIC) are
reported as Online. The outputs confirm that the chassis cluster remains operational.
195

7. Delete the SPC primary control link. The command deletes any remaining SPC control ports on both
nodes.

user@host# delete chassis cluster control-ports


user@host# commit

8. Disconnect the SPC primary control link cable before proceeding.

9. Configure the SCB primary control link.

user@host# set chassis cluster scb-control-ports 0


user@host# commit

10. Connect the SCB primary control link cable.

11. Verify that the chassis cluster remains operational, using the show chassis cluster interfaces
command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 ixlv0 Up Disabled Disabled
1 igb0 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-3/0/7 Up / Up Disabled
fab0
fab1 xe-15/0/7 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
196

reth0 Down Not configured


reth1 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

{primary:node0}
user@host> show chassis fpc pic-status
node0:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

node1:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

The chassis cluster control link reports an up status and the remote node's cards SPC and PIC are
reported as Online.

Transition from SCB to SPC with Dual Control Links

IN THIS SECTION

Requirements | 197

Configuration | 197
197

This example provides steps for a control link transition from an SCB to an SPC dual control link
concurrently.

Requirements
Before you begin:

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

• Physically connect the control ports on the devices. See "Connecting SRX Series Devices to Create a
Chassis Cluster" on page 34.

Configuration

IN THIS SECTION

Procedure | 197

Procedure

To transition from SCB to SPC control links concurrently:

1. Delete the SCB secondary control link configuration.

{primary:node0}[edit]
user@host# delete chassis cluster scb-control-ports 1
user@host# commit

2. Disconnect the SCB secondary control link cable.

3. Connect the SPC secondary control link cable.

4. Configure the SPC secondary control link, and commit.

{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 2 port 1
user@host# set chassis cluster control-ports fpc 14 port 1
user@host# commit
198

5. Verify that both the primary and secondary control interfaces are up on both nodes.

In operational mode, enter the show chassis cluster interfaces command to confirm that the chassis
cluster is functioning properly.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 ixlv0 Up Disabled Disabled
1 igb0 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-3/0/7 Up / Up Disabled
fab0
fab1 xe-15/0/7 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

{primary:node0}
user@host> show chassis fpc pic-status
node0:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
199

PIC 0 Online 20x10GE SFPP- np-cache/services-offload


PIC 1 Online 20x10GE SFPP- np-cache/services-offload

node1:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

6. Delete the SCB primary control link.

user@host# delete chassis cluster scb-control-ports 0


user@host# commit

7. Disconnect the SCB primary control link cable.

8. Connect the SPC primary control link cable.

9. Configure the SPC primary control link.

{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 2 port 0
user@host# set chassis cluster control-ports fpc 14 port 0
user@host# commit

10. Verify that both the primary and secondary control interfaces are up on both nodes, using the show
chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 ixlv0 Up Disabled Disabled
1 igb0 Up Disabled Disabled
200

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-3/0/7 Up / Up Disabled
fab0
fab1 xe-15/0/7 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

{primary:node0}
user@host> show chassis fpc pic-status
node0:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload

node1:
--------------------------------------------------------------------------
Slot 2 Online SPC3
PIC 0 Online SPU Cp-Flow
PIC 1 Online SPU Flow
Slot 3 Online SRX5k IOC4 10G
PIC 0 Online 20x10GE SFPP- np-cache/services-offload
PIC 1 Online 20x10GE SFPP- np-cache/services-offload
201

RELATED DOCUMENTATION

Connecting SRX Series Firewalls to Create a Chassis Cluster | 34


SRX Series Chassis Cluster Configuration Overview | 13

Chassis Cluster Dual Fabric Links

IN THIS SECTION

Understanding Chassis Cluster Dual Fabric Links | 201

Example: Configuring the Chassis Cluster Dual Fabric Links with Matching Slots and Ports | 202

Example: Configuring Chassis Cluster Dual Fabric Links with Different Slots and Ports | 206

Dual fabric links remove single point of failure in a chassis cluster setup. If one fabric link fails and one
remains functional, all sessions are maintained between the two nodes and the chassis cluster status is
preserved. for more information, see the following topics:

Understanding Chassis Cluster Dual Fabric Links

You can connect two fabric links between each device in a cluster, which provides a redundant fabric
link between the members of a cluster. Having two fabric links helps to avoid a possible single point of
failure.

When you use dual fabric links, the RTOs and probes are sent on one link and the fabric-forwarded and
flow-forwarded packets are sent on the other link. If one fabric link fails, the other fabric link handles the
RTOs and probes, as well as the data forwarding. The system selects the physical interface with the
lowest slot, PIC, or port number on each node for the RTOs and probes.

For all SRX Series Firewalls, you can connect two fabric links between two devices, effectively reducing
the chance of a fabric link failure.

In most SRX Series Firewalls in a chassis cluster, you can configure any pair of Gigabit Ethernet
interfaces or any pair of 10-Gigabit interfaces to serve as the fabric between nodes.

For dual fabric links, both of the child interface types should be the same type. For example, both should
be Gigabit Ethernet interfaces or 10-Gigabit interfaces.
202

SRX300, SRX320, SRX340, and SRX345 devices support Gigabit Ethernet interfaces only.

SRX380 devices support any of Gigabit Ethernet and 10-Gigabit Ethernet interfaces.

SEE ALSO

Understanding Chassis Cluster Fabric Interfaces | 55

Example: Configuring the Chassis Cluster Dual Fabric Links with


Matching Slots and Ports

IN THIS SECTION

Requirements | 202

Overview | 202

Configuration | 203

Verification | 205

This example shows how to configure the chassis cluster fabric with dual fabric links with matching slots
and ports. The fabric is the back-to-back data connection between the nodes in a cluster. Traffic on one
node that needs to be processed on the other node or to exit through an interface on the other node
passes over the fabric. Session state information also passes over the fabric.

Requirements
Before you begin, set the chassis cluster ID and chassis cluster node ID. See "Example: Setting the
Chassis Cluster Node ID and Cluster ID" on page 40.

Overview
In most SRX Series Firewalls in a chassis cluster, you can configure any pair of Gigabit Ethernet
interfaces or any pair of 10-Gigabit interfaces to serve as the fabric between nodes.

You cannot configure filters, policies, or services on the fabric interface. Fragmentation is not supported
on the fabric link. The MTU size is 8984 bytes. We recommend that no interface in the cluster exceed
this MTU size. Jumbo frame support on the member links is enabled by default.
203

This example illustrates how to configure the fabric link with dual fabric links with matching slots and
ports on each node.

A typical configuration is where the dual fabric links are formed with matching slots/ports on each node.
That is, ge-3/0/0 on node 0 and ge-10/0/0 on node 1 match, as do ge-0/0/0 on node 0 and ge-7/0/0 on node 1
(the FPC slot offset is 7).

Only the same type of interfaces can be configured as fabric children, and you must configure an equal
number of child links for fab0 and fab1.

If you are connecting each of the fabric links through a switch, you must enable the jumbo frame feature
on the corresponding switch ports. If both of the fabric links are connected through the same switch, the
RTO-and-probes pair must be in one virtual LAN (VLAN) and the data pair must be in another VLAN.
Here, too, the jumbo frame feature must be enabled on the corresponding switch ports.

Configuration

IN THIS SECTION

Procedure | 203

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set interfaces fab0 fabric-options member-interfaces ge-0/0/0
set interfaces fab0 fabric-options member-interfaces ge-3/0/0
set interfaces fab1 fabric-options member-interfaces ge-7/0/0
set interfaces fab1 fabric-options member-interfaces ge-10/0/0

Step-by-Step Procedure

To configure the chassis cluster fabric with dual fabric links with matching slots and ports on each node:
204

• Specify the fabric interfaces.

{primary:node0}[edit]
user@host# set interfaces fab0 fabric-options member-interfaces ge-0/0/0
user@host# set interfaces fab0 fabric-options member-interfaces ge-3/0/0
user@host# set interfaces fab1 fabric-options member-interfaces ge-7/0/0
user@host# set interfaces fab1 fabric-options member-interfaces ge-10/0/0

Results

From configuration mode, confirm your configuration by entering the show interfaces command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

{primary:node0}[edit]
user@host# show interfaces
...
fab0 {
fabric-options {
member-interfaces {
ge-0/0/0;
ge-3/0/0;
}
}
}
fab1 {
fabric-options {
member-interfaces {
ge-7/0/0;
ge-10/0/0;
}
}
}

If you are done configuring the device, enter commit from configuration mode.
205

Verification

IN THIS SECTION

Verifying the Chassis Cluster Fabric | 205

Verifying the Chassis Cluster Fabric

Purpose

Verify the chassis cluster fabric.

Action

From operational mode, enter the show interfaces terse | match fab command.

{primary:node0}
user@host> show interfaces terse | match fab
ge-0/0/0.0 up up aenet --> fab0.0
ge-3/0/0.0 up up aenet --> fab0.0
ge-7/0/0.0 up up aenet --> fab1.0
ge-10/0/0.0 up up aenet --> fab1.0
fab0 up up
fab0.0 up up inet 10.17.0.200/24
fab1 up up
fab1.0 up up inet 10.18.0.200/24

SEE ALSO

Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming | 18
206

Example: Configuring Chassis Cluster Dual Fabric Links with Different


Slots and Ports

IN THIS SECTION

Requirements | 206

Overview | 206

Configuration | 207

Verification | 208

This example shows how to configure the chassis cluster fabric with dual fabric links with different slots
and ports. The fabric is the back-to-back data connection between the nodes in a cluster. Traffic on one
node that needs to be processed on the other node or to exit through an interface on the other node
passes over the fabric. Session state information also passes over the fabric.

Requirements
Before you begin, set the chassis cluster ID and chassis cluster node ID. See "Example: Setting the
Chassis Cluster Node ID and Cluster ID" on page 40.

Overview
In most SRX Series Firewalls in a chassis cluster, you can configure any pair of Gigabit Ethernet
interfaces or any pair of 10-Gigabit interfaces to serve as the fabric between nodes.

You cannot configure filters, policies, or services on the fabric interface. Fragmentation is not supported
on the fabric link.

The maximum transmission unit (MTU) size supported is 8984 We recommend that no interface in the
cluster exceed this MTU size. Jumbo frame support on the member links is enabled by default.

This example illustrates how to configure the fabric link with dual fabric links with different slots and
ports on each node.

Make sure you physically connect the RTO-and-probes link to the RTO-and-probes link on the other
node. Likewise, make sure you physically connect the data link to the data link on the other node.

That is, physically connect the following two pairs:

• The node 0 RTO-and-probes link ge-2/1/9 to the node 1 RTO-and-probes link ge-11/0/0
207

• The node 0 data link ge-2/2/5 to the node 1 data link ge-11/3/0

Only the same type of interfaces can be configured as fabric children, and you must configure an equal
number of child links for fab0 and fab1.

If you are connecting each of the fabric links through a switch, you must enable the jumbo frame feature
on the corresponding switch ports. If both of the fabric links are connected through the same switch, the
RTO-and-probes pair must be in one virtual LAN (VLAN) and the data pair must be in another VLAN.
Here too, the jumbo frame feature must be enabled on the corresponding switch ports.

Configuration

IN THIS SECTION

Procedure | 207

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set interfaces fab0 fabric-options member-interfaces ge-2/1/9
set interfaces fab0 fabric-options member-interfaces ge-2/2/5
set interfaces fab1 fabric-options member-interfaces ge-11/0/0
set interfaces fab1 fabric-options member-interfaces ge-11/3/0

Step-by-Step Procedure

To configure the chassis cluster fabric with dual fabric links with different slots and ports on each node:

• Specify the fabric interfaces.

{primary:node0}[edit]
user@host# set interfaces fab0 fabric-options member-interfaces ge-2/1/9
user@host# set interfaces fab0 fabric-options member-interfaces ge-2/2/5
208

user@host# set interfaces fab1 fabric-options member-interfaces ge-11/0/0


user@host# set interfaces fab1 fabric-options member-interfaces ge-11/3/0

Results

From configuration mode, confirm your configuration by entering the show interfaces command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

{primary:node0}[edit]
user@host# show interfaces
...
fab0 {
fabric-options {
member-interfaces {
ge-2/1/9;
ge-2/2/5;
}
}
}
fab1 {
fabric-options {
member-interfaces {
ge-11/0/0;
ge-11/3/0;
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying the Chassis Cluster Fabric | 209


209

Verifying the Chassis Cluster Fabric

Purpose

Verify the chassis cluster fabric.

Action

From operational mode, enter the show interfaces terse | match fab command.

{primary:node0}
user@host> show interfaces terse | match fab
ge-2/1/9.0 up up aenet --> fab0.0
ge-2/2/5.0 up up aenet --> fab0.0
ge-11/0/0.0 up up aenet --> fab1.0
ge-11/3/0.0 up up aenet --> fab1.0
fab0 up up
fab0.0 up up inet 30.17.0.200/24
fab1 up up
fab1.0 up up inet 30.18.0.200/24

RELATED DOCUMENTATION

Connecting SRX Series Firewalls to Create a Chassis Cluster | 34


SRX Series Chassis Cluster Configuration Overview | 13

Monitoring of Global-Level Objects in a Chassis


Cluster

IN THIS SECTION

Understanding SPU Monitoring | 210

Understanding flowd Monitoring | 211


210

Understanding Cold-Sync Monitoring | 212

There are various types of objects to monitor as you work with devices configured as chassis clusters,
including global-level objects and objects that are specific to redundancy groups. This section describes
the monitoring of global-level objects.

The SRX5000 lines have one or more Services Processing Units (SPUs) that run on a Services Processing
Card (SPC). All flow-based services run on the SPU. Other SRX Series Firewalls have a flow-based
forwarding process, flowd, which forwards packets through the device.

Understanding SPU Monitoring

SPU monitoring tracks the health of the SPUs and of the central point (CP). The chassis manager on each
SPC monitors the SPUs and the central point, and also maintains the heartbeat with the Routing Engine
chassisd. In this hierarchical monitoring system, chassisd is the center for hardware failure detection.
SPU monitoring is enabled by default.

SPU monitoring is supported on SRX4600 and SRX5000 line devices.

Persistent SPU and central point failure on a node is deemed a catastrophic Packet Forwarding Engine
(PFE) failure. In this case, the node's PFE is disabled in the cluster by reducing the priorities of
redundancy groups x to 0.

• A central point failure triggers failover to the secondary node. The failed node's PFE, which includes
all SPCs and all I/O cards (IOCs), is automatically restarted. If the secondary central point has failed
as well, the cluster is unable to come up because there is no primary device. Only the data plane
(redundancy group x) is failed over.

• A single, failed SPU causes failover of redundancy group x to the secondary node. All IOCs and SPCs
on the failed node are restarted and redundancy group x is failed over to the secondary node.
Failover to the secondary node is automatic without the need for user intervention. When the failed
(former) primary node has its failing component restored, failback is determined by the preempt
configuration for the redundancy group x. The interval for dead SPU detection is 30 seconds.

On SRX5400, SRX5600, and SRX5800 SPCs, the Routing Engine monitors the health of the chassis
manager. The chassis manager sends a heartbeat message to the Routing Engine chassisd every second.
When the Routing Engine chassisd detects a heartbeat loss, it initiates a power cycle for the entire SPC.
If multiple recoveries fail within a certain timeframe, the Routing Engine powers off the SPC to prevent
it from affecting the entire system.
211

This event triggers an alarm, indicating that a new field-replaceable unit (FRU) is needed.

The following list describes the limitations for inserting an SPC on SRX5400, SRX5600, and SRX5800
devices in chassis cluster mode:

• The chassis cluster must be in active/passive mode before and during the SPC insert procedure.

• A different number of SPCs cannot be inserted in two different nodes.

• A new SPC must be inserted in a slot that is higher than the central point slot.

The existing combo central point cannot be changed to a full central point after the new SPC is
inserted.

• During an SPC insert procedure, the IKE and IPsec configurations cannot be modified.

An SPC is not hot-insertable. Before inserting an SPC, the device must be taken offline. After
inserting an SPC, the device must be rebooted.

• Users cannot specify the SPU and the IKE instance to anchor a tunnel.

• After a new SPC is inserted, the existing tunnels cannot use the processing power of the new SPC
and redistribute it to the new SPC.

Understanding flowd Monitoring

Flowd monitoring tracks the health of the flowd process. Flowd monitoring is enabled by default.

Persistent flowd failure on a node is deemed a catastrophic Packet Forwarding Engine (PFE) failure. In
this case, the node's PFE is disabled in the cluster by reducing the priorities of redundancy groups x to 0.

A failed flowd process causes failover of redundancy group x to the secondary node. Failover to the
secondary node is automatic without the need for user intervention. When the failed (former) primary
node has its failing component restored, failback is determined by the preempt configuration for the
redundancy group x.

During SPC and flowd monitoring failures on a local node, the data plane redundancy group RG1+ fails
over to the other node that is in a good state. However, the control plane RG0 does not fail over and
remains primary on the same node as it was before the failure.
212

Understanding Cold-Sync Monitoring

The process of synchronizing the data plane runtime objects (RTOs) on the startup of the SPUs or flowd
is called cold sync. When all the RTOs are synchronized, the cold-sync process is complete, and the SPU
or flowd on the node is ready to take over for the primary node, if needed. The process of monitoring
the cold-sync state of all the SPUs or flowd on a node is called cold-sync monitoring. Keep in mind that
when preempt is enabled, cold-sync monitoring prevents the node from taking over the primary role
until the cold-sync process is completed for the SPUs or flowd on the node. Cold-sync monitoring is
enabled by default.

When the node is rebooted, or when the SPUs or flowd come back up from failure, the priority for all
the redundancy groups 1+ is 0. When an SPU or flowd comes up, it tries to start the cold-sync process
with its mirror SPU or flowd on the other node.

If this is the only node in the cluster, the priorities for all the redundancy groups 1+ stay at 0 until a new
node joins the cluster. Although the priority is at 0, the device can still receive and send traffic over its
interfaces. A priority of 0 implies that it cannot fail over in case of a failure. When a new node joins the
cluster, all the SPUs or flowd, as they come up, will start the cold-sync process with the mirror SPUs or
flowd of the existing node.

When the SPU or flowd of a node that is already up detects the cold-sync request from the SPU or
flowd of the peer node, it posts a message to the system indicating that the cold-sync process is
complete. The SPUs or flowd of the newly joined node posts a similar message. However, they post this
message only after all the RTOs are learned and cold-sync is complete. On receipt of completion
messages from all the SPUs or flowd, the priority for redundancy groups 1+ moves to the configured
priority on each node if there are no other failures of monitored components, such as interfaces. This
action ensures that the existing primary node for redundancy 1+ groups always moves to the configured
priority first. The node joining the cluster later moves to its configured priorities only after all its SPUs or
flowd have completed their cold-sync process. This action in turn guarantees that the newly added node
is ready with all the RTOs before it takes over the primary role.

Understanding Cold-Sync Monitoring with SPU Replacement or Expansion

If your SRX5600 or SRX5800 Firewall is part of a chassis cluster, when you replace a Services
Processing Card (SPC) with a SPC2 or an SPC3 on the device, you must fail over all redundancy groups
to one node.

For SRX5400 devices, SPC2 and SPC3 are supported.

The following events take place during this scenario:

• When the SPC2 is installed on a node (for example, on node 1, the secondary node), node 1 is shut
down so the SPC2 can be installed.
213

• Once node 1 is powered up and rejoins the cluster, the number of SPUs on node 1 will be higher
than the number of SPUs on node 0, the primary node. Now, one node (node 0) still has an old SPC
while the other node has the new SPC2; SPC2s have four SPUs per card, and the older SPCs have
two SPUs per card.

The cold-sync process is based on node 0 total SPU number. Once those SPUs in node 1
corresponding to node 0 SPUs have completed the cold-sync, the node 1 will declare cold-sync
completed. Since the additional SPUs in node 1 do not have the corresponding node 0 SPUs, there is
nothing to be synchronized and failover from node 0 to node 1 does not cause any issue.

SPU monitoring functionality monitors all SPUs and reports if there are any SPU failure.

For example assume that both nodes originally have 2 existing SPCs and you have replaced both
SPCs with SPC2 on node 1. Now we have 4 SPUs in node 0 and 8 SPUs in node 1. The SPU
monitoring function monitors the 4 SPUs on node 0 and 8 SPUs on node 1. If any of those 8 SPUs
failed in node 1, the SPU monitoring will still report to the Juniper Services Redundancy Protocol
(jsrpd) process that there is an SPU failure. The jsrpd process controls chassis clustering.

• Once node 1 is ready to failover, you can initiate all redundancy group failover manually to node 1.
Node 0 will be shut down to replace its SPC with the SPC2. After the replacement, node 0 and node
1 will have exactly the same hardware setup.

Once node 0 is powered up and rejoins the cluster, the system will operate as a normal chassis cluster.

Starting from Junos OS Release 15.1X49-D120, when the cold-sync process is still in progress on SRX
Series Firewall in chassis cluster, and if the control link is down, a delay (of 30 seconds) is expected
before the node takes transition from the secondary state to the primary state.

RELATED DOCUMENTATION

Understanding Chassis Cluster Redundancy Group Interface Monitoring | 214


Example: Configuring Chassis Cluster Redundancy Group Interface Monitoring | 215
Understanding Chassis Cluster Redundancy Group IP Address Monitoring | 259
Example: Configuring Chassis Cluster Redundancy Group IP Address Monitoring | 261
214

Monitoring Chassis Cluster Interfaces

IN THIS SECTION

Understanding Chassis Cluster Redundancy Group Interface Monitoring | 214

Example: Configuring Chassis Cluster Redundancy Group Interface Monitoring | 215

Interface monitoring monitors the state of an interface by checking if the interface is in an up or down
state. When one or more monitored interfaces fail, the redundancy group fails over to the other node in
the cluster. For more information, see the following topics:

Understanding Chassis Cluster Redundancy Group Interface Monitoring

IN THIS SECTION

Benefits of Monitoring Chassis Cluster Redundancy Group Interfaces | 215

For a redundancy group to automatically failover to another node, its interfaces must be monitored.
When you configure a redundancy group, you can specify a set of interfaces that the redundancy group
is to monitor for status (or “health”) to determine whether the interface is up or down. A monitored
interface can be a child interface of any of its redundant Ethernet interfaces. When you configure an
interface for a redundancy group to monitor, you give it a weight.

Every redundancy group has a threshold tolerance value initially set to 255. When an interface
monitored by a redundancy group becomes unavailable, its weight is subtracted from the redundancy
group's threshold. When a redundancy group's threshold reaches 0, it fails over to the other node. For
example, if redundancy group 1 was primary on node 0, on the threshold-crossing event, redundancy
group 1 becomes primary on node 1. In this case, all the child interfaces of redundancy group 1's
redundant Ethernet interfaces begin handling traffic.

To check the interface weight, use the following commands:

• show chassis cluster information


215

• show chassis cluster interfaces

We do not recommend configuring data plane modules such as interface monitoring and IP monitoring
on redundancy group 0 (RG0) for SRX Series Firewalls in a chassis cluster.

Be cautious and judicious in your use of redundancy group 0 manual failovers. A redundancy group 0
failover implies a Routing Engine (RE) failover, in which case all processes running on the primary node
are killed and then spawned on the new primary Routing Engine (RE). This failover could result in loss of
state, such as routing state, and degrade performance by introducing system churn.

A redundancy group failover occurs because the cumulative weight of the redundancy group's
monitored interfaces has brought its threshold value to 0. When the monitored interfaces of a
redundancy group on both nodes reach their thresholds at the same time, the redundancy group is
primary on the node with the lower node ID, in this case node 0.

• If you want to dampen the failovers occurring because of interface monitoring failures, use the hold-
down-interval statement.

• If a failover occurs on redundancy group 0 (RG0), the interface monitoring on the RG0 secondary is
disabled for 30 seconds. This prevents failover of other redundancy groups along with RG0 failover.

Benefits of Monitoring Chassis Cluster Redundancy Group Interfaces

• Helps to determine the status of a specific interface in a chassis cluster setup by a specific
redundancy group.

• Enables automatic failover of an interface to another node if the interface is down.

SEE ALSO

Understanding Chassis Cluster Redundancy Groups | 91

Example: Configuring Chassis Cluster Redundancy Group Interface


Monitoring

IN THIS SECTION

Requirements | 216

Overview | 216
216

Configuration | 217

Verification | 222

This example shows how to specify that an interface be monitored by a specific redundancy group for
automatic failover to another node. You assign a weight to the interface to be monitored also shows
how to verify the process of the remaining threshold of a monitoring interface by configuring two
interfaces from each node and mapping them to redundancy groups.

Requirements
Before you begin, create a redundancy group. See "Example: Configuring Chassis Cluster Redundancy
Groups" on page 95.

Overview

IN THIS SECTION

Topology | 217

To retrieve the remaining redundancy group threshold after a monitoring interface is down, you can
configure your system to monitor the health of the interfaces belonging to a redundancy group. When
you assign a weight to an interface to be monitored, the system monitors the interface for availability. If
a physical interface fails, the weight is deducted from the corresponding redundancy group's threshold.
Every redundancy group has a threshold of 255. If the threshold hits 0, a failover is triggered, even if the
redundancy group is in manual failover mode and the preempt option is not enabled.

In this example, you check the process of the remaining threshold of a monitoring interface by
configuring two interfaces from each node and mapping them to redundancy group 1 (RG1), each with
different weights. You use 130 and 140 for node 0 interfaces and 150 and 120 for node 1 interfaces.
You configure one interface from each node and map the interfaces to redundancy group 2 (RG2), each
with default weight of 255.

Figure 35 on page 217 illustrates the network topology used in this example.
217

Topology

Figure 35: SRX Series Chassis Cluster Interface Monitoring Topology Example

Configuration

IN THIS SECTION

CLI Quick Configuration | 217

Procedure | 218

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the edit hierarchy level, and then enter commit from configuration mode.

set chassis cluster reth-count 3


set chassis cluster redundancy-group 0 node 0 priority 254
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 200
set chassis cluster redundancy-group 1 node 1 priority 100
218

set chassis cluster redundancy-group 1 interface-monitor ge-0/0/1 weight 130


set chassis cluster redundancy-group 1 interface-monitor ge-0/0/2 weight 140
set chassis cluster redundancy-group 1 interface-monitor ge-8/0/1 weight 150
set chassis cluster redundancy-group 1 interface-monitor ge-8/0/2 weight 120
set chassis cluster redundancy-group 2 node 0 priority 200
set chassis cluster redundancy-group 2 node 1 priority 100
set chassis cluster redundancy-group 2 interface-monitor ge-0/0/3 weight 255
set chassis cluster redundancy-group 2 interface-monitor ge-8/0/3 weight 255
set interfaces ge-0/0/1 gigether-options redundant-parent reth0
set interfaces ge-0/0/2 gigether-options redundant-parent reth1
set interfaces ge-0/0/3 gigether-options redundant-parent reth2
set interfaces ge-8/0/1 gigether-options redundant-parent reth0
set interfaces ge-8/0/2 gigether-options redundant-parent reth1
set interfaces ge-8/0/3 gigether-options redundant-parent reth2
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 family inet address 10.1.1.1/24
set interfaces reth1 redundant-ether-options redundancy-group 1
set interfaces reth1 unit 0 family inet address 10.2.2.2/24
set interfaces reth2 redundant-ether-options redundancy-group 2
set interfaces reth2 unit 0 family inet address 10.3.3.3/24

Procedure

Step-by-Step Procedure

The following example requires you to navigate various levels in the configuration hierarchy. For
instructions on how to do that, see Using the CLI Editor in Configuration Mode in the Junos OS CLI User
Guide.

To configure chassis cluster interface monitoring:

1. Specify the number of redundant Ethernet interfaces.

[edit chassis cluster]


user@host# set reth-count 3
219

2. Set up redundancy group 0 for the Routing Engine failover properties, and set up RG1 and RG2 (all
interfaces are in one redundancy group in this example) to define the failover properties for the
redundant Ethernet interfaces.

[edit chassis cluster]


user@host# set redundancy-group 0 node 0 priority 254
user@host# set redundancy-group 0 node 1 priority 1
user@host# set redundancy-group 1 node 0 priority 200
user@host# set redundancy-group 1 node 1 priority 100
user@host# set redundancy-group 2 node 0 priority 200
user@host# set redundancy-group 2 node 1 priority 100

3. Set up interface monitoring to monitor the health of the interfaces and trigger redundancy group
failover.

We do not recommend interface monitoring for RG0, because it causes the control plane to switch
from one node to another node in case interface flap occurs.

[edit chassis cluster]


user@host# set redundancy-group 1 interface-monitor ge-0/0/1 weight 130
user@host# set redundancy-group 1 interface-monitor ge-0/0/2 weight 140
user@host# set redundancy-group 1 interface-monitor ge-8/0/1 weight 150
user@host# set redundancy-group 1 interface-monitor ge-0/0/2 weight 120
user@host# set redundancy-group 2 interface-monitor ge-0/0/3 weight 255
user@host# set redundancy-group 2 interface-monitor ge-8/0/3 weight 255

Interface failover only occurs after the weight reaches zero.

4. Set up the redundant Ethernet (reth) interfaces and assign them to a zone.

[edit interfaces]
user@host# set ge-0/0/1 gigether-options redundant-parent reth0
user@host# set ge-0/0/2 gigether-options redundant-parent reth1
user@host# set ge-0/0/3 gigether-options redundant-parent reth2
user@host# set ge-8/0/1 gigether-options redundant-parent reth0
user@host# set ge-8/0/2 gigether-options redundant-parent reth1
user@host# set ge-8/0/3 gigether-options redundant-parent reth2
user@host# set reth0 redundant-ether-options redundancy-group 1
user@host# set reth0 unit 0 family inet address 10.1.1.1/24
user@host# set reth1 redundant-ether-options redundancy-group 1
user@host# set reth1 unit 0 family inet address 10.2.2.2/24
220

user@host# set reth2 redundant-ether-options redundancy-group 2


user@host# set reth2 unit 0 family inet address 10.3.3.3/24

Results

From configuration mode, confirm your configuration by entering the show chassis and show interfaces
commands. If the output does not display the intended configuration, repeat the configuration
instructions in this example to correct it.

[edit]
user@host# show chassis
cluster {
reth-count 3;
redundancy-group 0 {
node 0 priority 254;
node 1 priority 1;
}
redundancy-group 1 {
node 0 priority 200;
node 1 priority 100;
interface-monitor {
ge-0/0/1 weight 130;
ge-0/0/2 weight 140;
ge-8/0/1 weight 150;
ge-8/0/2 weight 120;
}
}
redundancy-group 2 {
node 0 priority 200;
node 1 priority 100;
interface-monitor {
ge-0/0/3 weight 255;
ge-8/0/3 weight 255;
}
}
}
[edit]
user@host# show interfaces
ge-0/0/1 {
gigether-options {
redundant-parent reth0;
221

}
}
ge-0/0/2 {
gigether-options {
redundant-parent reth1;
}
}
ge-0/0/3 {
gigether-options {
redundant-parent reth2;
}
}
ge-8/0/1 {
gigether-options {
redundant-parent reth0;
}
}
ge-8/0/2 {
gigether-options {
redundant-parent reth1;
}
}
ge-8/0/3 {
gigether-options {
redundant-parent reth2;
}
}
reth0 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 10.1.1.1/24;
}
}
}
reth1 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
222

address 10.2.2.2/24;
}
}
}
reth2 {
redundant-ether-options {
redundancy-group 2;
}
unit 0 {
family inet {
address 10.3.3.3/24;
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying Chassis Cluster Status | 223

Verifying Chassis Cluster Interfaces | 224

Verifying Chassis Cluster Information | 226

Verifying Interface ge-0/0/1 Status After Disabling Interface ge-0/0/1 of RG1 in Node 0 with a Weight
of 130 | 228

Verifying Chassis Cluster Status After Disabling Interface ge-0/0/1 of RG1 in Node 0 with a Weight of
130 | 228

Verifying Chassis Cluster Interfaces After Disabling Interface ge-0/0/1 of RG1 in Node 0 with a Weight
of 130 | 230

Verifying Chassis Cluster Information After Disabling Interface ge-0/0/1 of RG1 in Node 0 with a
Weight of 130 | 231

Verifying Interface ge-0/0/2 Is Disabled | 233

Verifying Chassis Cluster Status After Disabling Interface ge-0/0/2 | 234

Verifying Chassis Cluster Interfaces After Disabling Interface ge-0/0/2 | 235

Verifying Chassis Cluster Information After Disabling Interface ge-0/0/2 | 236

Verifying Interface Status After Disabling ge-0/0/3 | 238

Verifying Chassis Cluster Status After Disabling Interface ge-0/0/3 | 239


223

Verifying Chassis Cluster Interfaces After Disabling Interface ge-0/0/3 | 240

Verifying Chassis Cluster Information After Disabling Interface ge-0/0/3 | 241

Verifying That Interface ge-0/0/2 Is Enabled | 243

Verifying Chassis Cluster Status After Enabling Interface ge-0/0/2 | 244

Verifying Chassis Cluster Interfaces After Enabling Interface ge-0/0/2 | 245

Verifying Chassis Cluster Information After Enabling Interface ge-0/0/2 | 246

Verifying Chassis Cluster RG2 Preempt | 248

Verifying Chassis Cluster Status After Preempting RG2 | 249

Verifying That Interface ge-0/0/3 Is Enabled | 250

Verifying Chassis Cluster Status After Enabling Interface ge-0/0/3 | 251

Verifying Chassis Cluster Interfaces After Enabling Interface ge-0/0/3 | 252

Verifying Chassis Cluster Information After Enabling Interface ge-0/0/3 | 253

The following sections walk you through the process of verifying and (in some cases) troubleshooting
the interface status. The process shows you how to check the status of each interface in the redundancy
group, check them again after they have been disabled, and looks for details about each interface, until
you have circled through all interfaces in the redundancy group.

In this example, you verify the process of the remaining threshold of a monitoring interface by
configuring two interfaces from each node and mapping them to RG1, each with different weights. You
use 130 and 140 for node 0 interfaces and 150 and 120 for node 1 interfaces. You configure one
interface from each node and map the interfaces to RG2, each with the default weight of 255.

Verifying Chassis Cluster Status

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
224

CS Cold Sync monitoring FL Fabric Connection monitoring


GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 2
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 1


node0 200 primary no no None
node1 100 secondary no no None

Redundancy group: 2 , Failover count: 1


node0 200 primary no no None
node1 100 secondary no no None

Meaning

Use the show chassis cluster status command to confirm that devices in the chassis cluster are
communicating properly, with one device functioning as the primary node and the other as the
secondary node.

Verifying Chassis Cluster Interfaces

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitoring interfaces in the cluster.
225

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA
0 em0 Up Disabled
1 em1 Down Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status
(Physical/Monitored)
fab0 ge-0/0/0 Up / Up
fab0
fab1 ge-8/0/0 Up / Up
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1
reth2 Up 2

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-8/0/2 120 Up 1
ge-8/0/1 150 Up 1
ge-0/0/2 140 Up 1
ge-0/0/1 130 Up 1
ge-8/0/3 255 Up 2
ge-0/0/3 255 Up 2
226

Meaning

The sample output confirms that monitoring interfaces are up and that the weight of each interface
being monitored is displayed correctly as configured. These values do not change if the interface goes
up or down. The weights only change for the redundant group and can be viewed when you use the show
chassis cluster information command.

Verifying Chassis Cluster Information

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitoring interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster information command.

{primary:node0}
user@host> show chassis cluster information

node0:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 22:56:27 hold secondary Hold timer expired
Feb 24 22:56:34 secondary primary Better priority (254/1)

Redundancy Group 1 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:12 secondary primary Remote yield (0/0)

Redundancy Group 2 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
227

Feb 24 23:16:13 secondary primary Remote yield (0/0)

Chassis cluster LED information:


Current LED color: Green
Last LED change reason: No failures

node1:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 22:56:34 hold secondary Hold timer expired

Redundancy Group 1 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired

Redundancy Group 2 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired

Chassis cluster LED information:


Current LED color: Green
Last LED change reason: No failures

Meaning

The sample output confirms that node 0 and node 1 are healthy, and the green LED on the device
indicates that there are no failures. Also, the default weight of the redundancy group (255) is displayed.
The default weight is deducted whenever an interface mapped to the corresponding redundancy group
goes down.

Refer to subsequent verification sections to see how the redundancy group value varies when a
monitoring interface goes down or comes up.
228

Verifying Interface ge-0/0/1 Status After Disabling Interface ge-0/0/1 of RG1 in Node 0 with a Weight
of 130

Purpose

Verify that the interface ge-0/0/1 is disabled on node 0.

Action

From configuration mode, enter the set interface ge-0/0/1 disable command.

{primary:node0}
user@host# set interface ge-0/0/1 disable
user@host# commit

node0:
configuration check succeeds
node1:
commit complete
node0:
commit complete

{primary:node0}
user@host# show interfaces ge-0/0/1
disable;
gigether-options {
redundant-parent reth0;
}

Meaning

The sample output confirms that interface ge-0/0/1 is disabled.

Verifying Chassis Cluster Status After Disabling Interface ge-0/0/1 of RG1 in Node 0 with a Weight of
130

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.
229

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 2
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 1


node0 200 primary no no None
node1 100 secondary no no None

Redundancy group: 2 , Failover count: 1


node0 200 primary no no None
node1 100 secondary no no None

Meaning

Use the show chassis cluster status command to confirm that devices in the chassis cluster are
communicating properly, with one device functioning as the primary node and the other as the
secondary node.
230

Verifying Chassis Cluster Interfaces After Disabling Interface ge-0/0/1 of RG1 in Node 0 with a Weight
of 130

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitoring interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA
0 em0 Up Disabled
1 em1 Down Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status
(Physical/Monitored)
fab0 ge-0/0/0 Up / Up
fab0
fab1 ge-8/0/0 Up / Up
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down 1
reth1 Up 1
reth2 Up 2

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Interface Monitoring:
231

Interface Weight Status Redundancy-group


ge-8/0/2 120 Up 1
ge-8/0/1 150 Up 1
ge-0/0/2 140 Up 1
ge-0/0/1 130 Down 1
ge-8/0/3 255 Up 2
ge-0/0/3 255 Up 2

Meaning

The sample output confirms that monitoring interface ge-0/0/1 is down.

Verifying Chassis Cluster Information After Disabling Interface ge-0/0/1 of RG1 in Node 0 with a
Weight of 130

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitoring interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster information command.

{primary:node0}
user@host> show chassis cluster information

node0:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 22:56:27 hold secondary Hold timer expired
Feb 24 22:56:34 secondary primary Better priority (254/1)

Redundancy Group 1 , Current State: primary, Weight: 125

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
232

Feb 24 23:16:12 secondary primary Remote yield (0/0)

Redundancy Group 2 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:13 secondary primary Remote yield (0/0)

Chassis cluster LED information:


Current LED color: Green
Last LED change reason: No failures

Failure Information:

Interface Monitoring Failure Information:


Redundancy Group 1, Monitoring status: Unhealthy
Interface Status
ge-0/0/1 Down

node1:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 22:56:34 hold secondary Hold timer expired

Redundancy Group 1 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired

Redundancy Group 2 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down
233

Meaning

The sample output confirms that in node 0, the RG1 weight is reduced to 125 (that is, 255 minus 130)
because monitoring interface ge-0/0/1 (weight of 130) went down. The monitoring status is unhealthy,
the device LED is amber, and the interface status of ge-0/0/1 is down.

If interface ge-0/0/1 is brought back up, the weight of RG1 in node 0 becomes 255. Conversely, if
interface ge-0/0/2 is also disabled, the weight of RG1 in node 0 becomes 0 or less (in this example, 125
minus 140 = -15) and triggers failover, as indicated in the next verification section.

Verifying Interface ge-0/0/2 Is Disabled

Purpose

Verify that interface ge-0/0/2 is disabled on node 0.

Action

From configuration mode, enter the set interface ge-0/0/2 disable command.

{primary:node0}
user@host# set interface ge-0/0/2 disable
user@host# commit

node0:
configuration check succeeds
node1:
commit complete
node0:
commit complete

{primary:node0}
user@host# show interfaces ge-0/0/2
disable;
gigether-options {
redundant-parent reth1;
}

Meaning

The sample output confirms that interface ge-0/0/2 is disabled.


234

Verifying Chassis Cluster Status After Disabling Interface ge-0/0/2

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 2
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 2


node0 0 secondary no no IF
node1 100 primary no no None

Redundancy group: 2 , Failover count: 1


node0 200 primary no no None
node1 100 secondary no no None

Meaning

Use the show chassis cluster status command to confirm that devices in the chassis cluster are
communicating properly, with one device functioning as the primary node and the other as the
235

secondary node. On RG1, you see interface failure, because both interfaces mapped to RG1 on node 0
failed during interface monitoring.

Verifying Chassis Cluster Interfaces After Disabling Interface ge-0/0/2

Purpose

Verify information about chassis cluster interfaces.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA
0 em0 Up Disabled
1 em1 Down Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status
(Physical/Monitored)
fab0 ge-0/0/0 Up / Up
fab0
fab1 ge-8/0/0 Up / Up
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1
reth2 Up 2

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0
236

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-8/0/2 120 Up 1
ge-8/0/1 150 Up 1
ge-0/0/2 140 Down 1
ge-0/0/1 130 Down 1
ge-8/0/3 255 Up 2
ge-0/0/3 255 Up 2

Meaning

The sample output confirms that monitoring interfaces ge-0/0/1 and ge-0/0/2 are down.

Verifying Chassis Cluster Information After Disabling Interface ge-0/0/2

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitoring interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster information command.

{primary:node0}
user@host> show chassis cluster information

node0:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 22:56:27 hold secondary Hold timer expired
Feb 24 22:56:34 secondary primary Better priority (254/1)

Redundancy Group 1 , Current State: secondary, Weight: -15

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
237

Feb 24 23:16:12 secondary primary Remote yield (0/0)


Feb 24 23:31:36 primary secondary-hold Monitor failed: IF
Feb 24 23:31:37 secondary-hold secondary Ready to become secondary

Redundancy Group 2 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:13 secondary primary Remote yield (0/0)

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down

Failure Information:

Interface Monitoring Failure Information:


Redundancy Group 1, Monitoring status: Failed
Interface Status
ge-0/0/2 Down
ge-0/0/1 Down

node1:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 22:56:34 hold secondary Hold timer expired

Redundancy Group 1 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired
Feb 24 23:31:36 secondary primary Remote is in secondary hold

Redundancy Group 2 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired

Chassis cluster LED information:


238

Current LED color: Amber


Last LED change reason: Monitored objects are down

Meaning

The sample output confirms that in node 0, monitoring interfaces ge-0/0/1 and ge-0/0/2 are down. The
weight of RG1 on node 0 reached zero value, which triggered RG1 failover during use of the show chassis
cluster status command.

For RG2, the default weight of 255 is set for redundant Ethernet interface 2 (reth2). When interface
monitoring is required, we recommend that you use the default weight when you do not have backup
links like those in RG1. That is, if interface ge-0/0/3 is disabled, it immediately triggers failover because
the weight becomes 0 (255 minus 225), as indicated in the next verification section.

Verifying Interface Status After Disabling ge-0/0/3

Purpose

Verify that interface ge-0/0/3 is disabled on node 0.

Action

From configuration mode, enter the set interface ge-0/0/3 disable command.

{primary:node0}
user@host# set interface ge-0/0/3 disable
user@host# commit

node0:
configuration check succeeds
node1:
commit complete
node0:
commit complete

{primary:node0}
user@host# show interfaces ge-0/0/3
disable;
gigether-options {
239

redundant-parent reth2;
}

Meaning

The sample output confirms that interface ge-0/0/3 is disabled.

Verifying Chassis Cluster Status After Disabling Interface ge-0/0/3

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 2
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 2


node0 0 secondary no no IF
node1 100 primary no no None

Redundancy group: 2 , Failover count: 2


240

node0 0 secondary no no IF
node1 100 primary no no None

Meaning

Use the show chassis cluster status command to confirm that devices in the chassis cluster are
communicating properly, with one device functioning as the primary node and the other as the
secondary node.

Verifying Chassis Cluster Interfaces After Disabling Interface ge-0/0/3

Purpose

Verify information about chassis cluster interfaces.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA
0 em0 Up Disabled
1 em1 Down Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status
(Physical/Monitored)
fab0 ge-0/0/0 Up / Up
fab0
fab1 ge-8/0/0 Up / Up
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
241

reth1 Up 1
reth2 Up 2

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-8/0/2 120 Up 1
ge-8/0/1 150 Up 1
ge-0/0/2 140 Down 1
ge-0/0/1 130 Down 1
ge-8/0/3 255 Up 2
ge-0/0/3 255 Down 2

Meaning

The sample output confirms that monitoring interfaces ge-0/0/1, ge-0/0/2, and ge-0/0/3 are down.

Verifying Chassis Cluster Information After Disabling Interface ge-0/0/3

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitoring interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster information command.

{primary:node0}
user@host> show chassis cluster information

node0:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


242

Feb 24 22:56:27 hold secondary Hold timer expired


Feb 24 22:56:34 secondary primary Better priority (254/1)

Redundancy Group 1 , Current State: secondary, Weight: -15

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:12 secondary primary Remote yield (0/0)
Feb 24 23:31:36 primary secondary-hold Monitor failed: IF
Feb 24 23:31:37 secondary-hold secondary Ready to become secondary

Redundancy Group 2 , Current State: secondary, Weight: 0

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:13 secondary primary Remote yield (0/0)
Feb 24 23:35:57 primary secondary-hold Monitor failed: IF
Feb 24 23:35:58 secondary-hold secondary Ready to become secondary

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down

Failure Information:

Interface Monitoring Failure Information:


Redundancy Group 1, Monitoring status: Failed
Interface Status
ge-0/0/2 Down
ge-0/0/1 Down
Redundancy Group 2, Monitoring status: Failed
Interface Status
ge-0/0/3 Down

node1:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 22:56:34 hold secondary Hold timer expired
243

Redundancy Group 1 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired
Feb 24 23:31:36 secondary primary Remote is in secondary hold

Redundancy Group 2 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired
Feb 24 23:35:57 secondary primary Remote is in secondary hold

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down

Meaning

The sample output confirms that in node 0, monitoring interfaces ge-0/0/1, ge-0/0/2, and ge-0/0/3 are
down.

In regard to RG1, allowing any interface in node 0 go up triggers a failover only if the preempt option is
enabled. In the example, preempt is not enabled. Therefore the node should return to normal, with no
monitor failure showing for RG1.

Verifying That Interface ge-0/0/2 Is Enabled

Purpose

Verify that interface ge-0/0/2 is enabled on node 0.

Action

From configuration mode, enter the delete interfaces ge-0/0/2 disable command.

{primary:node0}
user@host# delete interfaces ge-0/0/2 disable
user@host# commit

node0:
244

configuration check succeeds


node1:
commit complete
node0:
commit complete

Meaning

The sample output confirms that interface ge-0/0/2 disable is deleted.

Verifying Chassis Cluster Status After Enabling Interface ge-0/0/2

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 2
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 2


node0 200 secondary no no None
245

node1 100 primary no no None

Redundancy group: 2 , Failover count: 2


node0 0 secondary no no IF
node1 100 primary no no None

Meaning

Use the show chassis cluster status command to confirm that devices in the chassis cluster are
communicating properly, with as one device functioning as the primary node and the other as the
secondary node.

Verifying Chassis Cluster Interfaces After Enabling Interface ge-0/0/2

Purpose

Verify information about chassis cluster interfaces.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA
0 em0 Up Disabled
1 em1 Down Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status
(Physical/Monitored)
fab0 ge-0/0/0 Up / Up
fab0
fab1 ge-8/0/0 Up / Up
fab1
246

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1
reth2 Up 2

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-8/0/2 120 Up 1
ge-8/0/1 150 Up 1
ge-0/0/2 140 Up 1
ge-0/0/1 130 Down 1
ge-8/0/3 255 Up 2
ge-0/0/3 255 Down 2

Meaning

The sample output confirms that monitoring interfaces ge-0/0/1 and ge-0/0/3 are down. Monitoring
interface ge-0/0/2 is up after the disable has been deleted.

Verifying Chassis Cluster Information After Enabling Interface ge-0/0/2

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitoring interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster information command.

{primary:node0}
user@host> show chassis cluster information

node0:
--------------------------------------------------------------------------
Redundancy Group Information:
247

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 22:56:27 hold secondary Hold timer expired
Feb 24 22:56:34 secondary primary Better priority (254/1)

Redundancy Group 1 , Current State: secondary, Weight: 125

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:12 secondary primary Remote yield (0/0)
Feb 24 23:31:36 primary secondary-hold Monitor failed: IF
Feb 24 23:31:37 secondary-hold secondary Ready to become secondary

Redundancy Group 2 , Current State: secondary, Weight: 0

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:13 secondary primary Remote yield (0/0)
Feb 24 23:35:57 primary secondary-hold Monitor failed: IF
Feb 24 23:35:58 secondary-hold secondary Ready to become secondary

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down

Failure Information:

Interface Monitoring Failure Information:


Redundancy Group 1, Monitoring status: Unhealthy
Interface Status
ge-0/0/1 Down
Redundancy Group 2, Monitoring status: Failed
Interface Status
ge-0/0/3 Down

node1:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255


248

Time From To Reason


Feb 24 22:56:34 hold secondary Hold timer expired

Redundancy Group 1 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired
Feb 24 23:31:36 secondary primary Remote is in secondary hold

Redundancy Group 2 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired
Feb 24 23:35:57 secondary primary Remote is in secondary hold

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down

Meaning

The sample output confirms that in node 0, monitoring interfaces ge-0/0/1 and ge-0/0/3 are down.
Monitoring interface ge-0/0/2 is active after the disable has been deleted.

Verifying Chassis Cluster RG2 Preempt

Purpose

Verify that the chassis cluster RG2 is preempted on node 0.

Action

From configuration mode, enter the set chassis cluster redundancy-group 2 preempt command.

{primary:node0}
user@host# set chassis cluster redundancy-group 2 preempt
user@host# commit

node0:
configuration check succeeds
249

node1:
commit complete
node0:
commit complete

Meaning

The sample output confirms that chassis cluster RG2 preempted on node 0.

In the next section, you check that RG2 fails over back to node 0 when preempt is enabled when the
disabled node 0 interface is brought online.

Verifying Chassis Cluster Status After Preempting RG2

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 2
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None
250

Redundancy group: 1 , Failover count: 2


node0 200 secondary no no None
node1 100 primary no no None

Redundancy group: 2 , Failover count: 2


node0 0 secondary yes no IF
node1 100 primary yes no None

Meaning

Use the show chassis cluster status command to confirm that devices in the chassis cluster are
communicating properly, with one device functioning as the primary node and the other as the
secondary node.

Verifying That Interface ge-0/0/3 Is Enabled

Purpose

Verify that interface ge-0/0/3 is enabled on node 0.

Action

From configuration mode, enter the delete interfaces ge-0/0/3 disable command.

{primary:node0}
user@host# delete interfaces ge-0/0/3 disable
user@host# commit

node0:
configuration check succeeds
node1:
commit complete
node0:
commit complete

Meaning

The sample output confirms that interface ge-0/0/3 disable has been deleted.
251

Verifying Chassis Cluster Status After Enabling Interface ge-0/0/3

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 2
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 2


node0 200 secondary no no None
node1 100 primary no no None

Redundancy group: 2 , Failover count: 3


node0 200 primary yes no None
node1 100 secondary yes no None

Meaning

Use the show chassis cluster status command to confirm that devices in the chassis cluster are
communicating properly, with one device functioning as the primary node and the other as the
secondary node.
252

Verifying Chassis Cluster Interfaces After Enabling Interface ge-0/0/3

Purpose

Verify information about chassis cluster interfaces.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA
0 em0 Up Disabled
1 em1 Down Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status
(Physical/Monitored)
fab0 ge-0/0/0 Up / Up
fab0
fab1 ge-8/0/0 Up / Up
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1
reth2 Up 2

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-8/0/2 120 Up 1
253

ge-8/0/1 150 Up 1
ge-0/0/2 140 Up 1
ge-0/0/1 130 Down 1
ge-8/0/3 255 Up 2
ge-0/0/3 255 Up 2

Meaning

The sample output confirms that monitoring interface ge-0/0/1 is down. Monitoring interfaces
ge-0/0/2, and ge-0/0/3 are up after deleting the disable.

Verifying Chassis Cluster Information After Enabling Interface ge-0/0/3

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitoring interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster information command.

{primary:node0}
user@host> show chassis cluster information

node0:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 22:56:27 hold secondary Hold timer expired
Feb 24 22:56:34 secondary primary Better priority (254/1)

Redundancy Group 1 , Current State: secondary, Weight: 125

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:12 secondary primary Remote yield (0/0)
Feb 24 23:31:36 primary secondary-hold Monitor failed: IF
254

Feb 24 23:31:37 secondary-hold secondary Ready to become secondary

Redundancy Group 2 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:12 hold secondary Hold timer expired
Feb 24 23:16:13 secondary primary Remote yield (0/0)
Feb 24 23:35:57 primary secondary-hold Monitor failed: IF
Feb 24 23:35:58 secondary-hold secondary Ready to become secondary
Feb 24 23:45:45 secondary primary Remote is in secondary hold

Chassis cluster LED information:


Current LED color: Green
Last LED change reason: No failures

Failure Information:

Interface Monitoring Failure Information:


Redundancy Group 1, Monitoring status: Unhealthy
Interface Status
ge-0/0/1 Down

node1:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 22:56:34 hold secondary Hold timer expired

Redundancy Group 1 , Current State: primary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired
Feb 24 23:31:36 secondary primary Remote is in secondary hold

Redundancy Group 2 , Current State: secondary, Weight: 255

Time From To Reason


Feb 24 23:16:10 hold secondary Hold timer expired
Feb 24 23:35:57 secondary primary Remote is in secondary hold
Feb 24 23:45:45 primary secondary-hold Preempt (100/200)
255

Feb 24 23:45:46 secondary-hold secondary Ready to become secondary

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down

Meaning

The sample output confirms that in node 0, monitoring interface ge-0/0/1 is down. RG2 on node 0 state
is back to primary state (because of the preempt enable) with a healthy weight of 255 when interface
ge-0/0/3 is back up.

SEE ALSO

Example: Configuring Chassis Cluster Redundancy Groups | 95

RELATED DOCUMENTATION

Monitoring IP Addresses on a Chassis Cluster | 255


Configuring Cluster Failover Parameters | 276
Chassis Cluster Redundancy Group Failover | 282

Monitoring IP Addresses on a Chassis Cluster

IN THIS SECTION

IP Monitoring Overview | 256

Understanding Chassis Cluster Redundancy Group IP Address Monitoring | 259

Example: Configuring Chassis Cluster Redundancy Group IP Address Monitoring | 261

Example: Configuring IP Monitoring on SRX5000 Line Devices for IOC2 and IOC3 | 266
256

Redundancy group IP address monitoring checks end-to-end connectivity and allows a redundancy
group to fail over if reth interface fails to reach a configured IP address. Redundancy groups on both
devices in a cluster can be configured to monitor specific IP addresses to determine whether an
upstream device in the network is reachable. For more information, see the following topics:

IP Monitoring Overview

IN THIS SECTION

Benefits of Monitoring IP Addresses in a Chassis Cluster | 258

IP monitoring checks the end-to-end connectivity of configured IP addresses and allows a redundancy
group to automatically fail over when the monitored IP address is not reachable through the redundant
Ethernet (reth) interface. Both the primary and secondary nodes in the chassis cluster monitor specific IP
addresses to determine whether an upstream device in the network is reachable.

IP monitoring allows for failover based upon end to-end reachability of a configured monitored IP
address. On SRX Series Firewalls, the reachability test is done by sending a ping to the monitored IP
address from both the primary node and the secondary node through the reth interface and checking if
a response is returned. The monitored IP address can be on a directly connected host in the same
subnet as the reth interface or on a remote device reachable through a next-hop router.

The reachability states of the monitored IP address are reachable, unreachable, and unknown. The status
is “unknown” if Packet Forwarding Engines are not yet up and running. The status changes to either
"reachable" or "unreachable," depending on the corresponding message from the Packet Forwarding
Engine.

We do not recommend configuring chassis cluster IP monitoring on Redundancy Group 0 (RG0) for SRX
Series Firewalls.

Table 18 on page 257 provides details of different combinations of monitored results from both the
primary and secondary nodes, and the corresponding actions by the Juniper Services Redundancy
Protocol (jsrpd) process.
257

Table 18: IP Monitoring Results and Failover Action

Primary Node Monitored Status Secondary Node Monitored Status Failover Action

Reachable Reachable No action

Unreachable Reachable Failover

Reachable Unreachable No action

Unreachable Unreachable No action

• You can configure up to 64 IP addresses for IP monitoring on SRX5000 line devices.

• On SRX Branch Series devices, when the reth interface has more than one physical interface
configured, IP monitoring for redundant groups is not supported. The SRX uses the lowest interface
in the bundle for tracking on the secondary node. If the peer forwards the reply on any other port
except the one it received it on, the SRX drops it.

• The minimum interval of IP monitoring is 1 second and the maximum is 30 seconds. Default interval
is 1 second.

• The minimum threshold of IP monitoring is 5 requests and the maximum is 15 requests. If the IP
monitoring request does not receive a response for consecutive requests (exceeding the threshold
value), IP monitoring reports that the monitored IP is unreachable. Default value for the threshold is
5.

• Reth interface not associated with Redundancy Group (RG) in IP monitoring CLI configuration is
supported.

Table 19 on page 257 provides details on multiple interface combinations of IOC2 and IOC3 with
maximum MAC numbers.

Table 19: Maximum MACs Supported for IP Monitoring on IOC2 and IOC3

Cards Interfaces Maximum MACs Supported for


IP Monitoring

IOC2 (SRX5K-MPC) 10XGE 10


258

Table 19: Maximum MACs Supported for IP Monitoring on IOC2 and IOC3 (Continued)

Cards Interfaces Maximum MACs Supported for


IP Monitoring

20GE 20

2X40GE 2

1X100GE 1

IOC3 (SRX5K-MPC3-40G10G or SRX5K- 24x10GE 24


MPC3-100G10G)

6x40GE 6

2x100GE + 4x10GE 6

Note the following limitations for IP monitoring support on SRX5000 line IOC2 and IOC3:

• IP monitoring is supported through the reth or the RLAG interface. If your configuration does not
specify either of these interfaces, the route lookup returns a non-reth/RLAG interface, which results
in a failure report.

• Equal-cost multipath (ECMP) routing is not supported in IP monitoring.

Benefits of Monitoring IP Addresses in a Chassis Cluster

• Helps determine the status of a specific IP address in a Chassis Cluster setup as unknown, reachable
or unreachable.

• Initiates failover based upon end to-end reachability of a configured monitored IP address. If the
monitored IP address becomes unreachable, the redundancy group can fail over to its backup to
maintain service.

SEE ALSO

SRX5400, SRX5600, and SRX5800 Services Gateway Card Overview


Chassis Cluster Redundancy Groups | 91
259

Understanding Chassis Cluster Redundancy Group IP Address Monitoring

Redundancy group IP address monitoring checks end-to-end connectivity and allows a redundancy
group to fail over because of the inability of a redundant Ethernet interface (known as a reth) to reach a
configured IP address. Redundancy groups on both devices in a cluster can be configured to monitor
specific IP addresses to determine whether an upstream device in the network is reachable. The
redundancy group can be configured such that if the monitored IP address becomes unreachable, the
redundancy group will fail over to its backup to maintain service. The primary difference between this
monitoring feature and interface monitoring is that IP address monitoring allows for failover when the
interface is still up but the network device it is connected to is not reachable for some reason. It may be
possible under those circumstances for the other node in the cluster to route traffic around the problem.

If you want to dampen the failovers occurring because of IP address monitoring failures, use the hold-
down-interval statement.

IP address monitoring configuration allows you to set not only the address to monitor and its failover
weight but also a global IP address monitoring threshold and weight. Only after the IP address
monitoring global-threshold is reached because of cumulative monitored address reachability failure will
the IP address monitoring global-weight value be deducted from the redundant group’s failover
threshold. Thus, multiple addresses can be monitored simultaneously as well as monitored to reflect
their importance to maintaining traffic flow. Also, the threshold value of an IP address that is
unreachable and then becomes reachable again will be restored to the monitoring threshold. This will
not, however, cause a failback unless the preempt option has been enabled.

When configured, the IP address monitoring failover value (global-weight) is considered along with
interface monitoring—if set—and built-in failover monitoring, including SPU monitoring, cold-sync
monitoring, and NPC monitoring (on supported platforms). The main IP addresses that should be
monitored are router gateway addresses to ensure that valid traffic coming into the services gateway
can be forwarded to the appropriate network router.

Starting in Junos OS Release 12.1X46-D35 and Junos OS Release 17.3R1, for all SRX Series Firewalls,
the reth interface supports proxy ARP.

One Services Processing Unit (SPU) or Packet Forwarding Engine (PFE) per node is designated to send
Internet Control Message Protocol (ICMP) ping packets for the monitored IP addresses on the cluster.
The primary PFE sends ping packets using Address Resolution Protocol (ARP) requests resolved by the
Routing Engine (RE). The source for these pings is the redundant Ethernet interface MAC and IP
addresses. The secondary PFE resolves ARP requests for the monitored IP address itself. The source for
these pings is the physical child MAC address and a secondary IP address configured on the redundant
Ethernet interface. For the ping reply to be received on the secondary interface, the I/O card (IOC),
central PFE processor, or Flex IOC adds both the physical child MAC address and the redundant
Ethernet interface MAC address to its MAC table. The secondary PFE responds with the physical child
MAC address to ARP requests sent to the secondary IP address configured on the redundant Ethernet
interface.
260

NOTE: IP address monitoring is not supported on SRX5000 line devices if the redundant
Ethernet interface is configured for a VPN routing and forwarding (VRF) instance.

The default interval to check the reachability of a monitored IP address is once per second. The interval
can be adjusted using the retry-interval command. The default number of permitted consecutive failed
ping attempts is 5. The number of allowed consecutive failed ping attempts can be adjusted using the
retry-count command. After failing to reach a monitored IP address for the configured number of
consecutive attempts, the IP address is determined to be unreachable and its failover value is deducted
from the redundancy group's global-threshold.

On SRX5600 and SRX5800 devices, only two of the 10 ports on each PIC of 40-port 1-Gigabit Ethernet
I/O cards (IOCs) can simultaneously enable IP address monitoring. Because there are four PICs per IOC,
this permits a total of eight ports per IOC to be monitored. If more than two ports per PIC on 40-port 1-
Gigabit Ethernet IOCs are configured for IP address monitoring, the commit will succeed but a log entry
will be generated, and the accuracy and stability of IP address monitoring cannot be ensured. This
limitation does not apply to any other IOCs or devices.

Once the IP address is determined to be unreachable, its weight is deducted from the global-threshold.
If the recalculated global-threshold value is not 0, the IP address is marked unreachable, but the global-
weight is not deducted from the redundancy group’s threshold. If the redundancy group IP monitoring
global-threshold reaches 0 and there are unreachable IP addresses, the redundancy group will
continuously fail over and fail back between the nodes until either an unreachable IP address becomes
reachable or a configuration change removes unreachable IP addresses from monitoring. Note that both
default and configured hold-down-interval failover dampening is still in effect.

Every redundancy group x has a threshold tolerance value initially set to 255. When an IP address
monitored by redundancy group x becomes unavailable, its weight is subtracted from the redundancy
group x's threshold. When redundancy group x's threshold reaches 0, it fails over to the other node. For
example, if redundancy group 1 was primary on node 0, on the threshold-crossing event, redundancy
group 1 becomes primary on node 1. In this case, all the child interfaces of redundancy group 1's
redundant Ethernet interfaces begin handling traffic.

A redundancy group x failover occurs because the cumulative weight of the redundancy group x's
monitored IP addresses and other monitoring has brought its threshold value to 0. When the monitored
IP addresses of redundancy group x on both nodes reach their thresholds at the same time, redundancy
group x is primary on the node with the lower node ID, which is typically node 0.

Upstream device failure detection for the chassis cluster feature is supported on SRX Series Firewalls.

Starting in Junos OS Release 15.1X49-D60 and Junos OS Release 17.3R1, configuring Address
Resolution Protocol (ARP) request throttling is supported on SRX5000 line devices. This feature allows
you to bypass the previously hard-coded ARP request throttling time default (10 seconds per SPU for
each IP address) and set the time to a greater value (10 through 100 seconds). Setting the throttling time
261

to a greater value reduces the high utilization of the Routing Engine, allowing it to work more efficiently.
You can configure the ARP request throttling time using the set forwarding-options next-hop arp-throttle
<seconds> command.

Monitoring can be accomplished only if the IP address is reachable on a redundant Ethernet interface
(known as a reth in CLI commands and interface listings), and IP addresses cannot be monitored over a
tunnel. For an IP address to be monitored through a redundant Ethernet interface on a secondary cluster
node, the interface must have a secondary IP address configured. IP address monitoring cannot be used
on a chassis cluster running in transparent mode. The maximum number of monitoring IP addresses that
can be configured per cluster is 64 for the SRX5000 line of devices, SRX1500, SRX4000 line of devices.

Redundancy group IP address monitoring is not supported for IPv6 destinations.

Example: Configuring Chassis Cluster Redundancy Group IP Address


Monitoring

IN THIS SECTION

Requirements | 261

Overview | 262

Configuration | 262

Verification | 265

This example shows how to configure redundancy group IP address monitoring for an SRX Series
Firewall in a chassis cluster.

Requirements
Before you begin:

• Set the chassis cluster node ID and cluster ID. See "Example: Setting the Node ID and Cluster ID for
Security Devices in a Chassis Cluster " on page 40

• Configure the chassis cluster management interface. See "Example: Configuring the Chassis Cluster
Management Interface" on page 46.

• Configure the chassis cluster fabric. See "Example: Configuring the Chassis Cluster Fabric Interfaces"
on page 60.
262

Overview
You can configure redundancy groups to monitor upstream resources by pinging specific IP addresses
that are reachable through redundant Ethernet interfaces on either node in a cluster. You can also
configure global threshold, weight, retry interval, and retry count parameters for a redundancy group.
When a monitored IP address becomes unreachable, the weight of that monitored IP address is
deducted from the redundancy group IP address monitoring global threshold. When the global threshold
reaches 0, the global weight is deducted from the redundancy group threshold. The retry interval
determines the ping interval for each IP address monitored by the redundancy group. The pings are sent
as soon as the configuration is committed. The retry count sets the number of allowed consecutive ping
failures for each IP address monitored by the redundancy group.

In this example, you configure the following settings for redundancy group 1:

• IP address to monitor—10.1.1.10

• IP address monitoring global-weight—100

• IP address monitoring global-threshold—200

The threshold applies cumulatively to all IP addresses monitored by the redundancy group.

• IP address retry-interval—3 seconds

• IP address retry-count—10

• Weight—100

• Redundant Ethernet interface—reth1.0

• Secondary IP address—10.1.1.101

Configuration

IN THIS SECTION

Procedure | 263
263

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
user@host#
set chassis cluster redundancy-group 1 ip-monitoring global-weight 100
set chassis cluster redundancy-group 1 ip-monitoring global-threshold 200
set chassis cluster redundancy-group 1 ip-monitoring retry-interval 3
set chassis cluster redundancy-group 1 ip-monitoring retry-count 10
set chassis cluster redundancy-group 1 ip-monitoring family inet 10.1.1.10 weight 100 interface
reth1.0 secondary-ip-address 10.1.1.101

Step-by-Step Procedure

To configure redundancy group IP address monitoring:

1. Specify a global monitoring weight.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 ip-monitoring global-weight 100

2. Specify the global monitoring threshold.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 ip-monitoring global-threshold 200

3. Specify the retry interval.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 ip-monitoring retry-interval 3
264

4. Specify the retry count.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 ip-monitoring retry-count 10

5. Specify the IP address to be monitored, weight, redundant Ethernet interface, and secondary IP
address.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 ip-monitoring family inet 10.1.1.10 weight
100 interface reth1.0 secondary-ip-address 10.1.1.101

Results

From configuration mode, confirm your configuration by entering the show chassis cluster redundancy-group
1 command. If the output does not display the intended configuration, repeat the configuration
instructions in this example to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

{primary:node0}[edit]
user@host# show chassis cluster redundancy-group 1
ip-monitoring {
global-weight 100;
global-threshold 200;
family {
inet {
10.1.1.10 {
weight 100;
interface reth1.0 secondary-ip-address 10.1.1.101;
}
}
}
}

If you are done configuring the device, enter commit from configuration mode.
265

Verification

IN THIS SECTION

Verifying the Status of Monitored IP Addresses for a Redundancy Group | 265

Verifying the Status of Monitored IP Addresses for a Redundancy Group

Purpose

Verify the status of monitored IP addresses for a redundancy group.

Action

From operational mode, enter the show chassis cluster ip-monitoring status command. For information
about a specific group, enter the show chassis cluster ip-monitoring status redundancy-group command.

{primary:node0}
user@host> show chassis cluster ip-monitoring status
node0:
--------------------------------------------------------------------------

Redundancy group: 1
Global threshold: 200
Current threshold: -120

IP address Status Failure count Reason Weight


10.1.1.10 reachable 0 n/a 100
10.1.1.101 reachable 0 n/a 100

node1:
--------------------------------------------------------------------------

Redundancy group: 1
Global threshold: 200
Current threshold: -120

IP address Status Failure count Reason Weight


266

10.1.1.10 reachable 0 n/a 100


10.1.1.101 reachable 0 n/a 100

Example: Configuring IP Monitoring on SRX5000 Line Devices for IOC2


and IOC3

IN THIS SECTION

Requirements | 266

Overview | 266

Configuration | 267

Verification | 274

This example shows how to monitor IP address on an SRX5000 line device with chassis cluster enabled.

Requirements
This example uses the following hardware and software:

• Two SRX5400 Services Gateways with MIC (SRX-MIC-10XG-SFPP [IOC2]), and one Ethernet switch

• Junos OS Release 15.1X49-D30

The procedure mentioned in this example is also applicable to IOC3.

Before you begin:

• Physically connect the two SRX5400 devices (back-to-back for the fabric and control ports).

• Configure the two devices to operate in a chassis cluster.

Overview

IN THIS SECTION

Topology | 267
267

IP address monitoring checks end-to-end reachability of the configured IP address and allows a
redundancy group to automatically fail over when it is not reachable through the child link of redundant
Ethernet (reth) interface. Redundancy groups on both devices, or nodes, in a cluster can be configured to
monitor specific IP addresses to determine whether an upstream device in the network is reachable.

Topology

In this example, two SRX5400 devices in a chassis cluster are connected to an Ethernet switch. The
example shows how the redundancy groups can be configured to monitor key upstream resources
reachable through redundant Ethernet interfaces on either node in a cluster.

You set the system to send pings every second, with 10 losses required to declare unreachability to peer.
You also set up a secondary IP address to allow testing from the secondary node.

In this example, you configure the following settings for redundancy group 1:

• IP address to be monitored—192.0.2.2, 198.51.100.2, 203.0.113.2

• IP monitoring global-weight—255

• IP monitoring global-threshold—240

• IP monitoring retry-interval—3 seconds

• IP monitoring retry-count—10

• Weight for monitored IP address—80

• Secondary IP addresses— 192.0.2.12, 198.51.100.12, 203.0.113.12

Configuration

IN THIS SECTION

CLI Quick Configuration | 268

Configuring IP Monitoring on a 10x10GE SFP+ MIC | 269


268

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details to match your network configuration, copy and paste the commands into
the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

set chassis cluster reth-count 10


set chassis cluster control-ports fpc 3 port 0
set chassis cluster control-ports fpc 0 port 0
set chassis cluster redundancy-group 0 node 0 priority 254
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 200
set chassis cluster redundancy-group 1 node 1 priority 199
set chassis cluster redundancy-group 1 ip-monitoring global-weight 255
set chassis cluster redundancy-group 1 ip-monitoring global-threshold 240
set chassis cluster redundancy-group 1 ip-monitoring retry-interval 3
set chassis cluster redundancy-group 1 ip-monitoring retry-count 10
set chassis cluster redundancy-group 1 ip-monitoring family inet 192.0.2.2 weight 80
set chassis cluster redundancy-group 1 ip-monitoring family inet 192.0.2.2 interface reth0.0
secondary-ip-address 192.0.2.12
set chassis cluster redundancy-group 1 ip-monitoring family inet 198.51.100.2 weight 80
set chassis cluster redundancy-group 1 ip-monitoring family inet 198.51.100.2 interface reth1.0
secondary-ip-address 198.51.100.12
set chassis cluster redundancy-group 1 ip-monitoring family inet 203.0.113.2 weight 80
set chassis cluster redundancy-group 1 ip-monitoring family inet 203.0.113.2 interface reth2.0
secondary-ip-address 203.0.113.12
set interfaces xe-1/2/1 gigether-options redundant-parent reth0
set interfaces xe-1/2/2 gigether-options redundant-parent reth2
set interfaces xe-1/2/3 gigether-options redundant-parent reth1
set interfaces xe-4/2/1 gigether-options redundant-parent reth0
set interfaces xe-4/2/2 gigether-options redundant-parent reth2
set interfaces xe-4/2/3 gigether-options redundant-parent reth1
set interfaces fab0 fabric-options member-interfaces xe-1/2/0
set interfaces fab1 fabric-options member-interfaces xe-4/2/0
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 family inet address 192.0.2.1/24
set interfaces reth1 redundant-ether-options redundancy-group 1
set interfaces reth1 unit 0 family inet address 198.51.100.1/24
set interfaces reth2 redundant-ether-options redundancy-group 1
set interfaces reth2 unit 0 family inet address 203.0.113.1/24
set security zones security-zone HOST host-inbound-traffic system-services any-service
269

set security zones security-zone HOST host-inbound-traffic protocols all


set security zones security-zone HOST interfaces all

Configuring IP Monitoring on a 10x10GE SFP+ MIC

Step-by-Step Procedure

To configure IP monitoring on a 10x10GE SFP+ MIC:

1. Specify the number of redundant Ethernet interfaces.

{primary:node0}[edit]
user@host# set chassis cluster reth-count 10

2. Configure the control ports.

{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 3 port 0
user@host# set chassis cluster control-ports fpc 0 port 0

3. Configure fabric interfaces.

{primary:node0}[edit]
user@host# set interfaces fab0 fabric-options member-interfaces xe-1/2/0
user@host# set interfaces fab1 fabric-options member-interfaces xe-4/2/0

4. Specify a redundancy group's priority for primacy on each node of the cluster. The higher number
takes precedence.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 0 node 0 priority 254
user@host# set chassis cluster redundancy-group 0 node 1 priority 1
user@host# set chassis cluster redundancy-group 1 node 0 priority 200
user@host# set chassis cluster redundancy-group 1 node 1 priority 199
270

5. Configure IP monitoring under redundancy-group 1 with global weight, global threshold, retry
interval and retry count.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 ip-monitoring global-weight 255
user@host# set chassis cluster redundancy-group 1 ip-monitoring global-threshold 240
user@host# set chassis cluster redundancy-group 1 ip-monitoring retry-interval 3
user@host# set chassis cluster redundancy-group 1 ip-monitoring retry-count 10

6. Configure the redundant Ethernet interfaces to redundancy-group 1. Assign a weight to the IP


address to be monitored, and configure a secondary IP address that will be used to send packets from
the secondary node to track the IP address being monitored.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 ip-monitoring family inet 192.0.2.2 weight
80
user@host# set chassis cluster redundancy-group 1 ip-monitoring family inet 192.0.2.2
interface reth0.0 secondary-ip-address 192.0.2.12
user@host# set chassis cluster redundancy-group 1 ip-monitoring family inet 198.51.100.2
weight 80
user@host# set chassis cluster redundancy-group 1 ip-monitoring family inet 198.51.100.2
interface reth1.0 secondary-ip-address 198.51.100.12
user@host# set chassis cluster redundancy-group 1 ip-monitoring family inet 203.0.113.2
weight 80
user@host# set chassis cluster redundancy-group 1 ip-monitoring family inet 203.0.113.2
interface reth2.0 secondary-ip-address 203.0.113.12

7. Assign child interfaces for the redundant Ethernet interfaces from node 0, node 1, and node 2.

{primary:node0}[edit]
user@host# set interfaces xe-1/2/1 gigether-options redundant-parent reth0
user@host# set interfaces xe-1/2/2 gigether-options redundant-parent reth2
user@host# set interfaces xe-1/2/3 gigether-options redundant-parent reth1
user@host# set interfaces xe-4/2/1 gigether-options redundant-parent reth0
user@host# set interfaces xe-4/2/2 gigether-options redundant-parent reth2
user@host# set interfaces xe-4/2/3 gigether-options redundant-parent reth1
271

8. Configure the redundant Ethernet interfaces to redundancy-group 1.

{primary:node0}[edit]
user@host# set interfaces reth0 redundant-ether-options redundancy-group 1
user@host# set interfaces reth0 unit 0 family inet address 192.0.2.1/24
user@host# set interfaces reth1 redundant-ether-options redundancy-group 1
user@host# set interfaces reth1 unit 0 family inet address 198.51.100.1/24
user@host# set interfaces reth2 redundant-ether-options redundancy-group 1
user@host# set interfaces reth2 unit 0 family inet address 203.0.113.1/24

9. Create security zone and assign interfaces to zone.

user@host# set security zones security-zone HOST host-inbound-traffic system-services any-


service
user@host# set security zones security-zone HOST host-inbound-traffic protocols all
user@host# set security zones security-zone HOST interfaces all

Results

From configuration mode, confirm your configuration by entering the show security chassis cluster and
show interfaces commands. If the output does not display the intended configuration, repeat the
configuration instructions in this example to correct it.

chassis {
cluster {
reth-count 10;
redundancy-group 0 {
node 0 priority 254;
node 1 priority 1;
}
redundancy-group 1 {
node 0 priority 200;
node 1 priority 199;
ip-monitoring {
global-weight 255;
global-threshold 240;
retry-interval 3;
retry-count 10;
family {
272

inet {
192.0.2.2 {
weight 80;
interface reth0.0 secondary-ip-address 192.0.2.12;
}
198.51.100.2 {
weight 80;
interface reth1.0 secondary-ip-address 198.51.100.12;
}
203.0.113.2 {
weight 80;
interface reth2.0 secondary-ip-address 203.0.113.12;
}
}
}
}
}
}
}
interfaces {
xe-1/2/1 {
gigether-options {

redundant-parent reth0;
}
}
xe-1/2/2 {
gigether-options {
redundant-parent reth2;
}
}
xe-1/2/3 {
gigether-options {
redundant-parent reth1;
}
}
xe-4/2/1 {
gigether-options {
redundant-parent reth0;
}
}
xe-4/2/2 {
gigether-options {
273

redundant-parent reth2;
}
}
xe-4/2/3 {
gigether-options {
redundant-parent reth1;
}
}
fab0 {
fabric-options {
member-interfaces {
xe-1/2/0;
}
}
}
fab1 {
fabric-options {
member-interfaces {
xe-4/2/0;
}
}
}
reth0 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 192.0.2.1/24;
}
}
}
reth1 {
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 198.51.100.1/24;
}
}
}
reth2 {
274

redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 203.0.113.1/24;
}
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying IP Monitoring Status | 274

Confirm the configuration is working properly.

Verifying IP Monitoring Status

Purpose

Verify the IP status being monitored from both nodes and the failure count for both nodes.

Action

From operational mode, enter the show chassis cluster ip-monitoring status command.

show chassis cluster ip-monitoring status

node0:
--------------------------------------------------------------------------

Redundancy group: 1
Global weight: 255
Global threshold: 240
275

Current threshold: 240

IP address Status Failure count Weight Reason


203.0.113.2 reachable 1 80 n/a
198.51.100.2 reachable 1 80 n/a
192.0.2.2 reachable 1 80 n/a

node1:
--------------------------------------------------------------------------

Redundancy group: 1
Global weight: 255
Global threshold: 240
Current threshold: 240

IP address Status Failure count Weight Reason


203.0.113.2 reachable 2 80 n/a
198.51.100.2 reachable 1 80 n/a
192.0.2.2 reachable 2 80 n/a

Meaning

All the monitored IP addresses are reachable.

Release History Table


Release Description

15.1X49-D60 Starting in Junos OS Release 15.1X49-D60 and Junos OS Release 17.3R1, configuring Address
Resolution Protocol (ARP) request throttling is supported on SRX5000 line devices.

12.1X46-D35 Starting in Junos OS Release 12.1X46-D35 and Junos OS Release 17.3R1, for all SRX Series
Firewalls, the reth interface supports proxy ARP.

RELATED DOCUMENTATION

Chassis Cluster Redundancy Groups | 91


Example: Configuring an Active/Passive Chassis Cluster on SRX5800 Firewalls | 369
Monitoring Chassis Cluster Interfaces | 214
276

Configuring Cluster Failover Parameters

IN THIS SECTION

Understanding Chassis Cluster Control Link Heartbeats, Failure, and Recovery | 276

Example: Configuring Chassis Cluster Control Link Recovery | 279

SRX Series devices in a chassis cluster uses heartbeat transmissions to determine the “health” of the
control link. If the number of missed heartbeats has reached the configured threshold, the system
assesses whether a failure condition exists. For more information, see the following topics:

Understanding Chassis Cluster Control Link Heartbeats, Failure, and


Recovery

IN THIS SECTION

Understanding Chassis Cluster Control Link Heartbeats | 276

Understanding Chassis Cluster Control Link Failure and Recovery | 277

Understanding Chassis Cluster Control Link Heartbeats

You specify the heartbeat threshold and heartbeat interval when you configure the chassis cluster.

The system monitors the control link's status by default.

For dual control links, which are supported on SRX5600 and SRX5800 lines, the Juniper Services
Redundancy Protocol process (jsrpd) sends and receives the control heartbeat messages on both control
links. As long as heartbeats are received on one of the control links, Junos OS considers the other node
to be alive.

The product of the heartbeat-threshold option and the heartbeat-interval option defines the wait time
before failover is triggered. The default values of these options produce a wait time of 3 seconds. A
277

heartbeat-threshold of 5 and a heartbeat-interval of 1000 milliseconds would yield a wait time of 5


seconds. Setting the heartbeat-threshold to 4 and the heartbeat-interval to 1250 milliseconds would
also yield a wait time of 5 seconds.

In a chassis cluster environment, if more than 1000 logical interfaces are used, the cluster heartbeat
timers are recommended to be increased from the default of 3 seconds. At maximum capacity on an
SRX4600, SRX5400, SRX5600 or an SRX5800 device, we recommend that you increase the configured
time before failover to at least 5 seconds.

Understanding Chassis Cluster Control Link Failure and Recovery

If the control link fails, Junos OS changes the operating state of the secondary node to ineligible for a
180-second countdown. If the fabric link also fails during the 180 seconds, Junos OS changes the
secondary node to primary; otherwise, after 180 seconds the secondary node state changes to disabled.

When the control link is down, a system log message is generated.

A control link failure is defined as not receiving heartbeats over the control link while heartbeats are still
being received over the fabric link.

In the event of a legitimate control link failure, redundancy group 0 remains primary on the node on
which it is currently primary, inactive redundancy groups x on the primary node become active, and the
secondary node enters a disabled state.

When the secondary node is disabled, you can still log in to the management port and run diagnostics.

To determine if a legitimate control link failure has occurred, the system relies on redundant liveliness
signals sent across both the control link and the fabric link.

The system periodically transmits probes over the fabric link and heartbeat signals over the control link.
Probes and heartbeat signals share a common sequence number that maps them to a unique time event.
Junos OS identifies a legitimate control link failure if the following two conditions exist:

• The threshold number of heartbeats were lost.

• At least one probe with a sequence number corresponding to that of a missing heartbeat signal was
received on the fabric link.

If the control link fails, the 180-second countdown begins and the secondary node state is ineligible. If
the fabric link fails before the 180-second countdown reaches zero, the secondary node becomes
primary because the loss of both links is interpreted by the system to indicate that the other node is
dead. Because concurrent loss of both control and fabric links means that the nodes are no longer
synchronizing states nor comparing priorities, both nodes might thus temporarily become primary, which
is not a stable operating state. However, once the control link is reestablished, the node with the higher
priority value automatically becomes primary, the other node becomes secondary, and the cluster
returns to normal operation.
278

When a legitimate control link failure occurs, the following conditions apply:

• Redundancy group 0 remains primary on the node on which it is currently primary (and thus its
Routing Engine remains active), and all redundancy groups x on the node become primary.

If the system cannot determine which Routing Engine is primary, the node with the higher priority
value for redundancy group 0 is primary and its Routing Engine is active. (You configure the priority
for each node when you configure the redundancy-group statement for redundancy group 0.)

• The system disables the secondary node.

To recover a device from the disabled mode, you must reboot the device. When you reboot the
disabled node, the node synchronizes its dynamic state with the primary node.

If you make any changes to the configuration while the secondary node is disabled, execute the commit
command to synchronize the configuration after you reboot the node. If you did not make configuration
changes, the configuration file remains synchronized with that of the primary node.

You cannot enable preemption for redundancy group 0. If you want to change the primary node for
redundancy group 0, you must do a manual failover.

When you use dual control links (supported on SRX5600 and SRX5800 devices), note the following
conditions:

• Host inbound or outbound traffic can be impacted for up to 3 seconds during a control link failure.
For example, consider a case where redundancy group 0 is primary on node 0 and there is a Telnet
session to the Routing Engine through a network interface port on node 1. If the currently active
control link fails, the Telnet session will lose packets for 3 seconds, until this failure is detected.

• A control link failure that occurs while the commit process is running across two nodes might lead to
commit failure. In this situation, run the commit command again after 3 seconds.

For SRX5600 and SRX5800 devices, dual control links require a second Routing Engine on each node of
the chassis cluster.

You can specify that control link recovery be done automatically by the system by setting the control-
link-recovery statement. In this case, once the system determines that the control link is healthy, it issues
an automatic reboot on the disabled node. When the disabled node reboots, the node joins the cluster
again.
279

Example: Configuring Chassis Cluster Control Link Recovery

IN THIS SECTION

Requirements | 279

Overview | 279

Configuration | 280

This example shows how to enable control link recovery, which allows the system to automatically take
over after the control link recovers from a failure.

Requirements
Before you begin:

• Understand chassis cluster control links. See "Understanding Chassis Cluster Control Plane and
Control Links" on page 67.

• Understand chassis cluster dual control links. See "Understanding Chassis Cluster Dual Control Links"
on page 172.

• Connect dual control links in a chassis cluster. See "Dual Control Link Connections for SRX Series
Firewalls in a Chassis Cluster" on page 174.

Overview
You can enable the system to perform control link recovery automatically. After the control link recovers,
the system takes the following actions:

• It checks whether it receives at least three consecutive heartbeats on the control link or, in the case
of dual control links (SRX5600 and SRX5800 devices only), on either control link. This is to ensure
that the control link is not flapping and is healthy.

• After it determines that the control link is healthy, the system issues an automatic reboot on the
node that was disabled when the control link failed. When the disabled node reboots, it can rejoin
the cluster. There is no need for any manual intervention.

In this example, you enable chassis cluster control link recovery.


280

Configuration

IN THIS SECTION

Procedure | 280

Procedure

Step-by-Step Procedure

To enable chassis cluster control-link-recovery:

1. Enable control link recovery.

{primary:node0}[edit]
user@host# set chassis cluster control-link-recovery

2. If you are done configuring the device, commit the configuration.

{primary:node0}[edit]
user@host# commit

RELATED DOCUMENTATION

Chassis Cluster Dual Control Links | 172


Example: Configure Chassis Cluster Control Ports for Dual Control Links | 178
281

Understanding Chassis Cluster Resiliency

IN THIS SECTION

Layer 1 for Detecting Hardware Faults and Software Failures | 281

Layer 2 for Probing Critical Paths | 281

Layer 3 for Detecting Control Link and Fabric Link Failure | 282

Benefits | 282

Junos OS uses a layered model to provide resiliency on SRX Series Firewalls that are in a chassis cluster
setup. In the event of a software or hardware component failure, the layered model ensures that the
system performance is not impacted.

Layer 1 for Detecting Hardware Faults and Software Failures

Layer 1 identifies and detects the components that are causing the software failures and impacting the
system performance. An alarm, syslog, or an SNMP trap is triggered to provide notifications about the
failures.

Layer 2 for Probing Critical Paths

Layer 2 probes the system’s critical paths to detect hardware and software failures that are not detected
by Layer 1.

Heartbeat communications validate the state of the paths between the two endpoints of the path. If any
component in the path fails, communication is lost and the system health status is communicated using
heartbeat messages sent from one end of the path to the other end.
282

Layer 3 for Detecting Control Link and Fabric Link Failure

Layer 3 determines the system health information from Layer 1 and Layer 2, shares the health status
between two nodes over the control links and fabric links, and makes the failover decision based on the
health status of the two nodes and the heartbeat status of the control links and fabric links. An alarm,
syslog, or an SNMP trap is triggered to provide notifications about the failures.

Layer 3 addresses the following software issues:

• em0 flapping

• Control path hardware or software component fails

• Fabric link is down and control link is alive

• Control link is down and fabric link is alive

• Both the control link and fabric link are down

Benefits

• Improve the failover time and stability.

• Identify the exact location of the fault or failure.

RELATED DOCUMENTATION

cluster (Chassis) | 606

Chassis Cluster Redundancy Group Failover

IN THIS SECTION

Understanding Chassis Cluster Redundancy Group Failover | 283

Understanding Chassis Cluster Redundancy Group Manual Failover | 288

Initiating a Chassis Cluster Manual Redundancy Group Failover | 289


283

Example: Configuring a Chassis Cluster with a Dampening Time Between Back-to-Back Redundancy Group
Failovers | 292

Understanding SNMP Failover Traps for Chassis Cluster Redundancy Group Failover | 293

Verifying Chassis Cluster Failover Status | 294

Clearing Chassis Cluster Failover Status | 296

A redundancy group (RG) includes and manages a collection of objects on both nodes of a cluster to
provide high-availability. Each redundancy group acts as an independent unit of failover and is primary
on only one node at a time. For more information, see the following topics:

Understanding Chassis Cluster Redundancy Group Failover

IN THIS SECTION

Preemptive Failover Delay Timer | 284

Chassis cluster employs a number of highly efficient failover mechanisms that promote high availability
to increase your system's overall reliability and productivity.

A redundancy group is a collection of objects that fail over as a group. Each redundancy group monitors
a set of objects (physical interfaces), and each monitored object is assigned a weight. Each redundancy
group has an initial threshold of 255. When a monitored object fails, the weight of the object is
subtracted from the threshold value of the redundancy group. When the threshold value reaches zero,
the redundancy group fails over to the other node. As a result, all the objects associated with the
redundancy group fail over as well. Graceful restart of the routing protocols enables the SRX Series
Firewall to minimize traffic disruption during a failover.

Back-to-back failovers of a redundancy group in a short interval can cause the cluster to exhibit
unpredictable behavior. To prevent such unpredictable behavior, configure a dampening time between
failovers. On failover, the previous primary node of a redundancy group moves to the secondary-hold
state and stays in the secondary-hold state until the hold-down interval expires. After the hold-down
interval expires, the previous primary node moves to the secondary state.
284

Configuring the hold-down interval prevents back-to-back failovers from occurring within the duration
of hold-down interval.

The hold-down interval affects manual failovers, as well as automatic failovers associated with
monitoring failures.

The default dampening time for a redundancy group 0 is 300 seconds (5 minutes) and is configurable to
up to 1800 seconds with the hold-down-interval statement. For some configurations, such as those with a
large number of routes or logical interfaces, the default interval or the user-configured interval might not
be sufficient. In such cases, the system automatically extends the dampening time in increments of 60
seconds until the system is ready for failover.

Redundancy groups x (redundancy groups numbered 1 through 128) have a default dampening time of 1
second, with a range from 0 through 1800 seconds.

On SRX Series Firewalls, chassis cluster failover performance is optimized to scale with more logical
interfaces. Previously, during redundancy group failover, gratuitous arp (GARP) is sent by the Juniper
Services Redundancy Protocol (jsrpd) process running in the Routing Engine on each logical interface to
steer the traffic to the appropriate node. With logical interface scaling, the Routing Engine becomes the
checkpoint and GARP is directly sent from the Services Processing Unit (SPU).

Preemptive Failover Delay Timer

A redundancy group is in the primary state (active) on one node and in the secondary state (backup) on
the other node at any given time.

You can enable the preemptive behavior on both nodes in a redundancy group and assign a priority
value for each node in the redundancy group. The node in the redundancy group with the higher
configured priority is initially designated as the primary in the group, and the other node is initially
designated as the secondary in the redundancy group.

When a redundancy group swaps the state of its nodes between primary and secondary, there is a
possibility that a subsequent state swap of its nodes can happen again soon after the first state swap.
This rapid change in states results in flapping of the primary and secondary systems.

Starting with Junos OS Release 17.4R1, a failover delay timer is introduced on SRX Series Firewalls in a
chassis cluster to limit the flapping of redundancy group state between the secondary and the primary
nodes in a preemptive failover.

To prevent the flapping, you can configure the following parameters:

• Preemptive delay –The preemptive delay time is the amount of time a redundancy group in a
secondary state waits when the primary state is down in a preemptive failover before switching to
the primary state. This delay timer delays the immediate failover for a configured period of time––
between 1 and 21,600 seconds.
285

• Preemptive limit–The preemptive limit restricts the number of preemptive failovers (between 1 to
50) during a configured preemptive period, when preemption is enabled for a redundancy group.

• Preemptive period–Time period (1 to 1440 seconds) during which the preemptive limit is applied,
that is, number of configured preemptive failovers are applied when preempt is enabled for a
redundancy group.

Consider the following scenario where you have configured a preemptive period as 300 seconds and
preemptive limit as 50.

When the preemptive limit is configured as 50, the count starts at 0 and increments with a first
preemptive failover; this process continues until the count reaches the configured preemptive limit, that
is 50, before the preemptive period expires. When the preemptive limit (50) is exceeded, you must
manually reset the preempt count to allow preemptive failovers to occur again.

When you have configured the preemptive period as 300 seconds, and if the time difference between
the first preemptive failover and the current failover has already exceeded 300 seconds, and the
preemptive limit (50) is not yet reached, then the preemptive period will be reset. After resetting, the
last failover is considered as the first preemptive failover of the new preemptive period and the process
starts all over again.

The preemptive delay can be configured independent of the failover limit. Configuring the preemptive
delay timer does not change the existing preemptive behavior.

This enhancement enables the administrator to introduce a failover delay, which can reduce the number
of failovers and result in a more stable network state due to the reduction in active /standby flapping
within the redundancy group.

Understanding Transition from Primary State to Secondary State with Preemptive Delay

Consider the following example, where a redundancy group, that is primary on the node 0 is ready for
preemptive transition to the secondary state during a failover. Priority is assigned to each node and the
preemptive option is also enabled for the nodes.

Figure 36 on page 286 illustrates the sequence of steps in transition from the primary state to the
secondary state when a preemptive delay timer is configured.
286

Figure 36: Transition from Primary State to Secondary State with Preemptive Delay

1. The node in the primary state is ready for preemptive transition to secondary state if the preemptive
option is configured, and the node in secondary state has the priority over the node in primary state.
If the preemptive delay is configured, the node in the primary state transitions to primary-preempt-
hold state . If preemptive delay is not configured, then instant transition to the secondary state
happens.

2. The node is in primary-preempt-hold state waiting for the preemptive delay timer to expire. The
preemptive delay timer is checked and transition is held until the timer expires. The primary node
stays in the primary-preempt-hold state until the timer expires, before transitioning to the secondary
state.

3. The node transitions from primary-preempt-hold state into secondary-hold state and then to the
secondary state.

4. The node stays in the secondary-hold state for the default time (1 second) or the configured time (a
minimum of 300 seconds), and then the node transitions to the secondary state.
287

If your chassis cluster setup experiences an abnormal number of flaps, you must check your link and
monitoring timers to make sure they are set correctly. Be careful when while setting timers in high
latency networks to avoid getting false positives.

Configuring Preemptive Delay Timer

This topic explains how to configure the delay timer on SRX Series Firewalls in a chassis cluster. Back-to-
back redundancy group failovers that occur too quickly can cause a chassis cluster to exhibit
unpredictable behavior. Configuring the delay timer and failover rate limit delays immediate failover for
a configured period of time.

To configure the preemptive delay timer and failover rate limit between redundancy group failovers:

1. Enable preemptive failover for a redundancy group.

You can set the delay timer between 1 and 21,600 seconds. Default value is 1 second.

{primary:node1}
[edit chassis cluster redundancy-group number preempt]
user@host# set delay interval

2. Set up a limit for preemptive failover.

You can set maximum number of preemptive failovers between 1 to 50 and time period during which
the limit is applied between 1 to 1440 seconds.

{primary:node1}[edit chassis cluster redundancy-group number preempt]


user@host# set limit limit period period

In the following example, you are setting the preemptive delay timer to 300 seconds, and the
preemptive limit to 10 for a premptive period of 600 seconds. That is, this configuration delays
immediate failover for 300 seconds, and it limits a maximum of 10 preemptive failovers in a duration of
600 seconds.

{primary:node1}[edit chassis cluster redundancy-group 1 preempt]


user@host# set delay 300 limit 10 period 600

You can use the clear chassis clusters preempt-count command to clear the preempt failover counter for all
redundancy groups. When a preempt limit is configured, the counter starts with a first preemptive
failover and the count is reduced; this process continues until the count reaches zero before the timer
expires. You can use this command to clear the preempt failover counter and reset it to start again.
288

SEE ALSO

Chassis Cluster Redundancy Groups | 91

Understanding Chassis Cluster Redundancy Group Manual Failover

You can initiate a redundancy group x (redundancy groups numbered 1 through 128) failover manually.
A manual failover applies until a failback event occurs.

For example, suppose that you manually do a redundancy group 1 failover from node 0 to node 1. Then
an interface that redundancy group 1 is monitoring fails, dropping the threshold value of the new
primary redundancy group to zero. This event is considered a failback event, and the system returns
control to the original redundancy group.

You can also initiate a redundancy group 0 failover manually if you want to change the primary node for
redundancy group 0. You cannot enable preemption for redundancy group 0.

If preempt is added to a redundancy group configuration, the device with the higher priority in the group
can initiate a failover to become primary. By default, preemption is disabled. For more information on
preemeption, see "preempt (Chassis Cluster)" on page 679.

When you do a manual failover for redundancy group 0, the node in the primary state transitions to the
secondary-hold state. The node stays in the secondary-hold state for the default or configured time (a
minimum of 300 seconds) and then transitions to the secondary state.

State transitions in cases where one node is in the secondary-hold state and the other node reboots, or
the control link connection or fabric link connection is lost to that node, are described as follows:

• Reboot case—The node in the secondary-hold state transitions to the primary state; the other node
goes dead (inactive).

• Control link failure case—The node in the secondary-hold state transitions to the ineligible state and
then to a disabled state; the other node transitions to the primary state.

• Fabric link failure case—The node in the secondary-hold state transitions directly to the ineligible
state.

Starting with Junos OS Release 12.1X46-D20 and Junos OS Release 17.3R1, fabric monitoring is
enabled by default. With this enabling, the node transitions directly to the ineligible state in case of
fabric link failures.

Starting with Junos OS Release 12.1X47-D10 and Junos OS Release 17.3R1, fabric monitoring is
enabled by default. With this enabling, the node transitions directly to the ineligible state in case of
fabric link failures.
289

Keep in mind that during an in-service software upgrade (ISSU), the transitions described here cannot
happen. Instead, the other (primary) node transitions directly to the secondary state because Juniper
Networks releases earlier than 10.0 do not interpret the secondary-hold state. While you start an ISSU,
if one of the nodes has one or more redundancy groups in the secondary-hold state, you must wait for
them to move to the secondary state before you can do manual failovers to make all the redundancy
groups be primary on one node.

Be cautious and judicious in your use of redundancy group 0 manual failovers. A redundancy group 0
failover implies a Routing Engine failover, in which case all processes running on the primary node are
killed and then spawned on the new primary Routing Engine. This failover could result in loss of state,
such as routing state, and degrade performance by introducing system churn.

In some Junos OS releases, for redundancy groups x, it is possible to do a manual failover on a node that
has 0 priority. We recommend that you use the show chassis cluster status command to check the
redundancy group node priorities before doing the manual failover. However, from Junos OS Releases
12.1X44-D25, 12.1X45-D20, 12.1X46-D10, and 12.1X47-D10 and later, the readiness check
mechanism for manual failover is enhanced to be more restrictive, so that you cannot set manual
failover to a node in a redundancy group that has 0 priority. This enhancement prevents traffic from
being dropped unexpectedly due to a failover attempt to a 0 priority node, which is not ready to accept
traffic.

Initiating a Chassis Cluster Manual Redundancy Group Failover

Before you begin, complete the following tasks:

• "Example: Configuring Chassis Cluster Redundancy Groups" on page 95

• "Example: Configuring Chassis Cluster Redundant Ethernet Interfaces" on page 103

You can initiate a failover manually with the request command. A manual failover bumps up the priority of
the redundancy group for that member to 255.

Be cautious and judicious in your use of redundancy group 0 manual failovers. A redundancy group 0
failover implies a Routing Engine (RE) failover, in which case all processes running on the primary node
are killed and then spawned on the new primary Routing Engine (RE). This failover could result in loss of
state, such as routing state, and degrade performance by introducing system churn.

Unplugging the power cord and holding the power button to initiate a chassis cluster redundancy group
failover might result in unpredictable behavior.

For redundancy groups x (redundancy groups numbered 1 through 128), it is possible to do a manual
failover on a node that has 0 priority. We recommend that you check the redundancy group node
priorities before doing the manual failover.
290

Use the show command to display the status of nodes in the cluster:

{primary:node0}
user@host> show chassis cluster status redundancy-group 0
Cluster ID: 9
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 254 primary no no
node1 1 secondary no no

Output to this command indicates that node 0 is primary.

Use the request command to trigger a failover and make node 1 primary:

{primary:node0}
user@host> request chassis cluster failover redundancy-group 0 node 1
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Initiated manual failover for redundancy group 0

Use the show command to display the new status of nodes in the cluster:

{secondary-hold:node0}
user@host> show chassis cluster status redundancy-group 0
Cluster ID: 9
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 2


node0 254 secondary-hold no yes
node1 255 primary no yes

Output to this command shows that node 1 is now primary and node 0 is in the secondary-hold state.
After 5 minutes, node 0 will transition to the secondary state.

You can reset the failover for redundancy groups by using the request command. This change is
propagated across the cluster.

{secondary-hold:node0}
user@host> request chassis cluster failover reset redundancy-group 0
node0:
--------------------------------------------------------------------------
291

No reset required for redundancy group 0.

node1:
--------------------------------------------------------------------------
Successfully reset manual failover for redundancy group 0

You cannot trigger a back-to-back failover until the 5-minute interval expires.

{secondary-hold:node0}
user@host> request chassis cluster failover redundancy-group 0 node 0
node0:
--------------------------------------------------------------------------
Manual failover is not permitted as redundancy-group 0 on node0 is in secondary-hold state.

Use the show command to display the new status of nodes in the cluster:

{secondary-hold:node0}
user@host> show chassis cluster status redundancy-group 0
Cluster ID: 9
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 2


node0 254 secondary-hold no no
node1 1 primary no no

Output to this command shows that a back-to-back failover has not occurred for either node.

After doing a manual failover, you must issue the reset failover command before requesting another
failover.

When the primary node fails and comes back up, election of the primary node is done based on regular
criteria (priority and preempt).
292

Example: Configuring a Chassis Cluster with a Dampening Time Between


Back-to-Back Redundancy Group Failovers

IN THIS SECTION

Requirements | 292

Overview | 292

Configuration | 292

This example shows how to configure the dampening time between back-to-back redundancy group
failovers for a chassis cluster. Back-to-back redundancy group failovers that occur too quickly can cause
a chassis cluster to exhibit unpredictable behavior.

Requirements
Before you begin:

• Understand redundancy group failover. See "Understanding Chassis Cluster Redundancy Group
Failover " on page 283.

• Understand redundancy group manual failover. See "Understanding Chassis Cluster Redundancy
Group Manual Failover" on page 288.

Overview
The dampening time is the minimum interval allowed between back-to-back failovers for a redundancy
group. This interval affects manual failovers and automatic failovers caused by interface monitoring
failures.

In this example, you set the minimum interval allowed between back-to-back failovers to 420 seconds
for redundancy group 0.

Configuration

IN THIS SECTION

Procedure | 293
293

Procedure

Step-by-Step Procedure

To configure the dampening time between back-to-back redundancy group failovers:

1. Set the dampening time for the redundancy group.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 0 hold-down-interval 420

2. If you are done configuring the device, commit the configuration.

{primary:node0}[edit]
user@host# commit

Understanding SNMP Failover Traps for Chassis Cluster Redundancy


Group Failover

Chassis clustering supports SNMP traps, which are triggered whenever there is a redundancy group
failover.

The trap message can help you troubleshoot failovers. It contains the following information:

• The cluster ID and node ID

• The reason for the failover

• The redundancy group that is involved in the failover

• The redundancy group’s previous state and current state

These are the different states that a cluster can be in at any given instant: hold, primary, secondary-hold,
secondary, ineligible, and disabled. Traps are generated for the following state transitions (only a
transition from a hold state does not trigger a trap):

• primary <–> secondary

• primary –> secondary-hold

• secondary-hold –> secondary


294

• secondary –> ineligible

• ineligible –> disabled

• ineligible –> primary

• secondary –> disabled

A transition can be triggered because of any event, such as interface monitoring, SPU monitoring,
failures, and manual failovers.

The trap is forwarded over the control link if the outgoing interface is on a node different from the node
on the Routing Engine that generates the trap.

You can specify that a trace log be generated by setting the traceoptions flag snmp statement.

Verifying Chassis Cluster Failover Status

IN THIS SECTION

Purpose | 294

Action | 294

Purpose

Display the failover status of a chassis cluster.

Action

From the CLI, enter the show chassis cluster status command:

{primary:node1}
user@host> show chassis cluster status
Cluster ID: 3
Node name Priority Status Preempt Manual failover

Redundancy-group: 0, Failover count: 1


node0 254 primary no no
295

node1 2 secondary no no

Redundancy-group: 1, Failover count: 1


node0 254 primary no no
node1 1 secondary no no

{primary:node1}
user@host> show chassis cluster status
Cluster ID: 15
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 5


node0 200 primary no no
node1 0 lost n/a n/a

Redundancy group: 1 , Failover count: 41


node0 101 primary no no
node1 0 lost n/a n/a

{primary:node1}
user@host> show chassis cluster status
Cluster ID: 15
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 5


node0 200 primary no no
node1 0 unavailable n/a n/a

Redundancy group: 1 , Failover count: 41


node0 101 primary no no
node1 0 unavailable n/a n/a
296

Clearing Chassis Cluster Failover Status

To clear the failover status of a chassis cluster, enter the clear chassis cluster failover-count command
from the CLI:

{primary:node1}
user@host> clear chassis cluster failover-count
Cleared failover-count for all redundancy-groups

Release History Table


Release Description

17.4R1 Starting with Junos OS Release 17.4R1, a failover delay timer is introduced on SRX Series Firewalls
in a chassis cluster to limit the flapping of redundancy group state between the secondary and the
primary nodes in a preemptive failover.

12.1X47-D10 Starting with Junos OS Release 12.1X47-D10 and Junos OS Release 17.3R1, fabric monitoring is
enabled by default. With this enabling, the node transitions directly to the ineligible state in case of
fabric link failures.

12.1X46-D20 Starting with Junos OS Release 12.1X46-D20 and Junos OS Release 17.3R1, fabric monitoring is
enabled by default. With this enabling, the node transitions directly to the ineligible state in case of
fabric link failures.

RELATED DOCUMENTATION

Monitoring of Global-Level Objects in a Chassis Cluster | 209


Monitoring Chassis Cluster Interfaces | 214
Monitoring IP Addresses on a Chassis Cluster | 255
4 CHAPTER

Chassis Cluster Operations

Aggregated Ethernet Interfaces in a Chassis Cluster | 298

NTP Time Synchronization on Chassis Cluster | 359

Active/Passive Chassis Cluster Deployments | 367

Multicast Routing and Asymmetric Routing on Chassis Cluster | 433

Ethernet Switching on Chassis Cluster | 454

Media Access Control Security (MACsec) on Chassis Cluster | 485

Understanding SCTP Behavior in Chassis Cluster | 505

Example: Encrypting Messages Between Two Nodes in a Chassis Cluster | 505


298

Aggregated Ethernet Interfaces in a Chassis Cluster

IN THIS SECTION

Understanding Link Aggregation Groups in a Chassis Cluster | 298

Example: Configuring Link Aggregation Groups in a Chassis Cluster | 300

Understanding Link Aggregation Group Failover in a Chassis Cluster | 305

Understanding LACP on Chassis Clusters | 307

Example: Configuring LACP on Chassis Clusters | 310

Example: Configuring Chassis Cluster Minimum Links | 321

Example: Configuring Chassis Cluster Redundant Ethernet Interface Link Aggregation Groups on an SRX5000
Line Device with IOC2 or IOC3 | 324

Understanding VRRP on SRX Series Firewalls | 329

VRRP failover-delay Overview | 332

Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant Ethernet Interfaces | 335

Example: Configuring VRRP for IPv6 | 347

IEEE 802.3ad link aggregation enables you to group Ethernet interfaces to form a single link layer
interface, also known as a link aggregation group (LAG) or bundle. Reth LAG interfaces combine
characteristics of reth interfaces and LAG interfaces. For more information, see the following topics:

Understanding Link Aggregation Groups in a Chassis Cluster

Support for Ethernet link aggregation groups (LAGs) based on IEEE 802.3ad makes it possible to
aggregate physical interfaces on a standalone device. LAGs on standalone devices provide increased
interface bandwidth and link availability. Aggregation of links in a chassis cluster allows a redundant
Ethernet interface to add more than two physical child interfaces thereby creating a redundant Ethernet
interface LAG. For SRX4600 and SRX5000 line of devices, a redundant Ethernet interface LAG can have
up to eight links per redundant Ethernet interface per node (for a total of 16 links per redundant
Ethernet interface). For SRX300 Series, SRX550M, SRX1500, and SRX4100/SRX4200 devices, a
redundant Ethernet interface LAG can have up to maximum four links per redundant Ethernet interface
per node (for a total of 8 links per redundant Ethernet interface).
299

The aggregated links in a redundant Ethernet interface LAG provide the same bandwidth and
redundancy benefits of a LAG on a standalone device with the added advantage of chassis cluster
redundancy. A redundant Ethernet interface LAG has two types of simultaneous redundancy. The
aggregated links within the redundant Ethernet interface on each node are redundant; if one link in the
primary aggregate fails, its traffic load is taken up by the remaining links. If enough child links on the
primary node fail, the redundant Ethernet interface LAG can be configured so that all traffic on the
entire redundant Ethernet interface fails over to the aggregate link on the other node. You can also
configure interface monitoring for LACP-enabled redundancy group reth child links for added protection.

Aggregated Ethernet interfaces, known as local LAGs, are also supported on either node of a chassis
cluster but cannot be added to redundant Ethernet interfaces. Local LAGs are indicated in the system
interfaces list using an ae- prefix. Likewise any child interface of an existing local LAG cannot be added
to a redundant Ethernet interface and vice versa. Note that it is necessary for the switch (or switches)
used to connect the nodes in the cluster to have a LAG link configured and 802.3ad enabled for each
LAG on both nodes so that the aggregate links are recognized as such and correctly pass traffic. The
total maximum number of combined individual node LAG interfaces (ae) and redundant Ethernet (reth)
interfaces per cluster is 128.

The redundant Ethernet interface LAG child links from each node in the chassis cluster must be
connected to a different LAG at the peer devices. If a single peer switch is used to terminate the
redundant Ethernet interface LAG, two separate LAGs must be used in the switch.

Links from different PICs or IOCs and using different cable types (for example, copper and fiber-optic)
can be added to the same redundant Ethernet interface LAG but the speed of the interfaces must be the
same and all interfaces must be in full duplex mode. We recommend, however, that for purposes of
reducing traffic processing overhead, interfaces from the same PIC or IOC be used whenever feasible.
Regardless, all interfaces configured in a redundant Ethernet interface LAG share the same virtual MAC
address.

SRX Series Firewalls interface-monitoring feature allows monitoring of redundant Ethernet/aggregated


Ethernet interfaces.

Redundant Ethernet interface configuration also includes a minimum-links setting that allows you to set
a minimum number of physical child links on the primary node in a given redundant Ethernet interface
that must be working for the interface to be up. The default minimum-links value is 1. Note that the
minimum-links setting only monitors child links on the primary node. Redundant Ethernet interfaces do
not use physical interfaces on the backup node for either ingress or egress traffic.

Note the following support details:

• Quality of service (QoS) is supported in a redundant Ethernet interface LAG. Guaranteed bandwidth
is, however, duplicated across all links. If a link is lost, there is a corresponding loss of guaranteed
bandwidth.

• Layer 2 transparent mode and Layer 2 security features are supported in redundant Ethernet
interface LAGs.
300

• Link Aggregation Control Protocol (LACP) is supported in chassis cluster deployments, where
aggregated Ethernet interfaces and redundant Ethernet interfaces are supported simultaneously.

• Chassis cluster management, control, and fabric interfaces cannot be configured as redundant
Ethernet interface LAGs or added to a redundant Ethernet interface LAG.

• Network processor (NP) bundling can coexist with redundant Ethernet interface LAGs on the same
cluster. However, assigning an interface simultaneously to a redundant Ethernet interface LAG and a
network processor bundle is not supported.

IOC2 cards do not have network processors but IOC1 cards do have them.

• Single flow throughput is limited to the speed of a single physical link regardless of the speed of the
aggregate interface.

On SRX300, SRX320, SRX340, SRX345, SRX380, and SRX550M devices, the speed mode and link mode
configuration is available for member interfaces of a reth interface.

For more information about Ethernet interface link aggregation and LACP, see the “Aggregated
Ethernet” information in the Interfaces User Guide for Security Devices.

SEE ALSO

Understanding Link Aggregation Control Protocol

Example: Configuring Link Aggregation Groups in a Chassis Cluster

IN THIS SECTION

Requirements | 301

Overview | 301

Configuration | 302

Verification | 304

This example shows how to configure a redundant Ethernet interface link aggregation group for a
chassis cluster. Chassis cluster configuration supports more than one child interface per node in a
redundant Ethernet interface. When at least two physical child interface links from each node are
301

included in a redundant Ethernet interface configuration, the interfaces are combined within the
redundant Ethernet interface to form a redundant Ethernet interface link aggregation group.

Requirements
Before you begin:

• Configure chassis cluster redundant interfaces. See "Example: Configuring Chassis Cluster Redundant
Ethernet Interfaces" on page 103.

• Understand chassis cluster redundant Ethernet interface link aggregation groups. See "Understanding
Link Aggregation Groups in a Chassis Cluster" on page 298.

Overview
For aggregation to take place, the switch used to connect the nodes in the cluster must enable IEEE
802.3ad link aggregation for the redundant Ethernet interface physical child links on each node. Because
most switches support IEEE 802.3ad and are also LACP capable, we recommend that you enable LACP
on SRX Series Firewalls. In cases where LACP is not available on the switch, you must not enable LACP
on SRX Series Firewalls.

In this example, you assign six Ethernet interfaces to reth1 to form the Ethernet interface link
aggregation group:

• ge-1/0/1—reth1

• ge-1/0/2—reth1

• ge-1/0/3—reth1

• ge-12/0/1—reth1

• ge-12/0/2—reth1

• ge-12/0/3—reth1

A maximum of eight physical interfaces per node in a cluster, for a total of 16 child interfaces, can be
assigned to a single redundant Ethernet interface when a redundant Ethernet interface LAG is being
configured.

Junos OS supports LACP and LAG on a redundant Ethernet interface, which is called RLAG.
302

Configuration

IN THIS SECTION

Procedure | 302

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]

set interfaces ge-1/0/1 gigether-options redundant-parent reth1


set interfaces ge-1/0/2 gigether-options redundant-parent reth1
set interfaces ge-1/0/3 gigether-options redundant-parent reth1
set interfaces ge-12/0/1 gigether-options redundant-parent reth1
set interfaces ge-12/0/2 gigether-options redundant-parent reth1
set interfaces ge-12/0/3 gigether-options redundant-parent reth1

Step-by-Step Procedure

To configure a redundant Ethernet interface link aggregation group:

• Assign Ethernet interfaces to reth1.

{primary:node0}[edit]
user@host# set interfaces ge-1/0/1 gigether-options redundant-parent reth1
user@host# set interfaces ge-1/0/2 gigether-options redundant-parent reth1
user@host# set interfaces ge-1/0/3 gigether-options redundant-parent reth1
user@host# set interfaces ge-12/0/1 gigether-options redundant-parent reth1
user@host# set interfaces ge-12/0/2 gigether-options redundant-parent reth1
user@host# set interfaces ge-12/0/3 gigether-options redundant-parent reth1
303

Results

From configuration mode, confirm your configuration by entering the show interfaces reth1 command. If
the output does not display the intended configuration, repeat the configuration instructions in this
example to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

user@host# show interfaces reth1


...
ge-1/0/1 {
gigether-options {
redundant-parent reth1;
}
}
ge-1/0/2 {
gigether-options {
redundant-parent reth1;
}
}
ge-1/0/3 {
gigether-options {
redundant-parent reth1;
}
}
ge-12/0/1 {
gigether-options {
redundant-parent reth1;
}
}
ge-12/0/2 {
gigether-options {
redundant-parent reth1;
}
}
ge-12/0/3 {
gigether-options {
redundant-parent reth1;
}
}
...
304

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying the Redundant Ethernet Interface LAG Configuration | 304

Verifying the Redundant Ethernet Interface LAG Configuration

Purpose

Verify the redundant Ethernet interface LAG configuration.

Action

From operational mode, enter the show interfaces terse | match reth command.

{primary:node0}
user@host> show interfaces terse | match reth
ge-1/0/1.0 up down aenet --> reth1.0
ge-1/0/2.0 up down aenet --> reth1.0
ge-1/0/3.0 up down aenet --> reth1.0
ge-12/0/1.0 up down aenet --> reth1.0
ge-12/0/2.0 up down aenet --> reth1.0
ge-12/0/3.0 up down aenet --> reth1.0
reth0 up down
reth0.0 up down inet 10.10.37.214/24
reth1 up down
reth1.0 up down inet

SEE ALSO

Example: Configuring Aggregated Ethernet Device with LAG and LACP (CLI Procedure)
305

Understanding Link Aggregation Group Failover in a Chassis Cluster

IN THIS SECTION

Scenario 1: Monitored Interface Weight Is 255 | 306

Scenario 2: Monitored Interface Weight Is 75 | 307

Scenario 3: Monitored Interface Weight Is 100 | 307

You control failover of redundant Ethernet (reth) interfaces in two ways:

• Using the minimum-links configuration setting. This parameters determines how many physical
members of a redundancy group must be up before the group is declared down. By default this
parameter is set to one, which means the redundancy group remains active if a single physical
interface is up on the primary node.
The default value for minimum links is 1.

• Using the interface-monitor configuration statement along with a weight value for each member in the
LAG. The interface weighting mechanism works by subtracting a failed interface's configured weight
from the redundancy group. The group begins with a weight of 255, and when the group falls to, or
below 0, the redundancy group is declared down.

NOTE: Its worth noting that the minimum-links and interface-monitor configuration statements
work independently. Crossing either the threshold of minimum links (on the primary node), or
the threshold of 0 on the redundancy group, triggers a switchover.

In most cases its a best practice to configure the weights of interface monitoring according to the
minimum-links setting. This configuration requires that the weights be equally distributed among the
monitored links such that when the number of active physical interface links falls below the minimum-links
setting, the computed weight for that redundancy group also falls to, or below, zero. This triggers a
failover of the redundant Ethernet interfaces link aggregation group (LAG) because both the number of
physical links falls below the minimum-links value and the LAG group's weight falls below 0.

To demonstrate this interaction, consider a reth0 interface LAG with four underlying physical links:

• The LAG is configured with a minimum-links setting of 2. With this setting failover is triggered when the
number of active physical links on the primary node is less than 2.
306

NOTE: When the physical link is Up and LACP is Down, a failover of the redundant Ethernet
interfaces link aggregation group (LAG) is triggered.

• The Interface-monitor weight values are used to monitor LAG link status and correctly calculate
failover weight.

Configure the underlying interface attached to the redundant Ethernet LAG.

{primary:node0}[edit]
user@host# set interfaces ge-0/0/4 gigether-options redundant-parent reth0
user@host# set interfaces ge-0/0/5 gigether-options redundant-parent reth0
user@host# set interfaces ge-0/0/6 gigether-options redundant-parent reth0
user@host# set interfaces ge-0/0/7 gigether-options redundant-parent reth0

Specify the minimum number of links for the redundant Ethernet interface as 2.

{primary:node0}[edit]
user@host# set interfaces reth0 redundant-ether-options minimum-links 2

Configure interface monitoring to monitor the health of the interfaces and trigger redundancy group
failover.

These scenarios provide examples of how redundant Ethernet LAG failover operates:

Scenario 1: Monitored Interface Weight Is 255

Specify the monitored interface weight as 255 for each underlying interface.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/6 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/7 weight 255

When 1 of the 4 interfaces fails there are still 3 active physical links and the redundant Ethernet LAG.
While this number exceeds the configured minimum links parameter, the loss of one interface with a
weight of 255 causes the group's weight to fall to 0, triggering a failover.
307

Scenario 2: Monitored Interface Weight Is 75

Specify the monitored interface weight as 75 for each underlying interface.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 75
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 75
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/6 weight 75
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/7 weight 75

In this case, when three physical links are down, the redundant Ethernet interface will go down due to
falling below the minimum-links value configured. Note that in this scenario the LAG group weight remains
above 0.

Scenario 3: Monitored Interface Weight Is 100

Specify the monitored interface weight as 100 for each underlying interface.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 100
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 100
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/6 weight 100
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/7 weight 100

In this case, when 3 of 4 physical links are down, the redundant Ethernet interface is declared down
both because the minimum-links value is not met, and due to the interface monitoring weights causing the
LAG group's weight to reach 0.

Of all the three scenarios, scenario 3 illustrates the most ideal way to manage redundant Ethernet LAG
failover and there will be minimum traffic loss.

Understanding LACP on Chassis Clusters

IN THIS SECTION

Chassis Cluster Redundant Ethernet Interface Link Aggregation Groups | 308

Sub-LAGs | 309
308

Supporting Hitless Failover | 309

Managing Link Aggregation Control PDUs | 310

You can combine multiple physical Ethernet ports to form a logical point-to-point link, known as a link
aggregation group (LAG) or bundle, such that a media access control (MAC) client can treat the LAG as if
it were a single link.

LAGs can be established across nodes in a chassis cluster to provide increased interface bandwidth and
link availability.

The Link Aggregation Control Protocol (LACP) provides additional functionality for LAGs. LACP is
supported in standalone deployments, where aggregated Ethernet interfaces are supported, and in
chassis cluster deployments, where aggregated Ethernet interfaces and redundant Ethernet interfaces
are supported simultaneously.

You configure LACP on a redundant Ethernet interface by setting the LACP mode for the parent link
with the lacp statement. The LACP mode can be off (the default), active, or passive.

This topic contains the following sections:

Chassis Cluster Redundant Ethernet Interface Link Aggregation Groups

A redundant Ethernet interface has active and standby links located on two nodes in a chassis cluster.
All active links are located on one node, and all standby links are located on the other node. You can
configure up to eight active links and eight standby links per node.

When at least two physical child interface links from each node are included in a redundant Ethernet
interface configuration, the interfaces are combined within the redundant Ethernet interface to form a
redundant Ethernet interface LAG.

Having multiple active redundant Ethernet interface links reduces the possibility of failover. For
example, when an active link is out of service, all traffic on this link is distributed to other active
redundant Ethernet interface links, instead of triggering a redundant Ethernet active/standby failover.

Aggregated Ethernet interfaces, known as local LAGs, are also supported on either node of a chassis
cluster but cannot be added to redundant Ethernet interfaces. Likewise, any child interface of an existing
local LAG cannot be added to a redundant Ethernet interface, and vice versa. The total maximum
number of combined individual node LAG interfaces (ae) and redundant Ethernet (reth) interfaces per
cluster is 128.

However, aggregated Ethernet interfaces and redundant Ethernet interfaces can coexist, because the
functionality of a redundant Ethernet interface relies on the Junos OS aggregated Ethernet framework.
309

For more information, see "Understanding Chassis Cluster Redundant Ethernet Interface Link
Aggregation Groups" on page 298.

Minimum Links

Redundant Ethernet interface configuration includes a minimum-links setting that allows you to set a
minimum number of physical child links in a redundant Ethernet interface LAG that must be working on
the primary node for the interface to be up. The default minimum-links value is 1. When the number of
physical links on the primary node in a redundant Ethernet interface falls below the minimum-links value,
the interface might be down even if some links are still working. For more information, see "Example:
Configuring Chassis Cluster Minimum Links" on page 321.

Sub-LAGs

LACP maintains a point-to-point LAG. Any port connected to the third point is denied. However, a
redundant Ethernet interface does connect to two different systems or two remote aggregated Ethernet
interfaces by design.

To support LACP on redundant Ethernet interface active and standby links, a redundant Ethernet
interface is created automatically to consist of two distinct sub-LAGs, where all active links form an
active sub-LAG and all standby links form a standby sub-LAG.

In this model, LACP selection logic is applied and limited to one sub-LAG at a time. In this way, two
redundant Ethernet interface sub-LAGs are maintained simultaneously while all the LACP advantages
are preserved for each sub-LAG.

It is necessary for the switches used to connect the nodes in the cluster to have a LAG link configured
and 802.3ad enabled for each LAG on both nodes so that the aggregate links are recognized as such and
correctly pass traffic.

The redundant Ethernet interface LAG child links from each node in the chassis cluster must be
connected to a different LAG at the peer devices. If a single peer switch is used to terminate the
redundant Ethernet interface LAG, two separate LAGs must be used in the switch.

Supporting Hitless Failover

With LACP, the redundant Ethernet interface supports hitless failover between the active and standby
links in normal operation. The term hitless means that the redundant Ethernet interface state remains up
during a failover.

The lacpd process manages both the active and standby links of the redundant Ethernet interfaces. A
redundant Ethernet interface state remains up when the number of active up links is equal to or more
than the number of minimum links configured. Therefore, to support hitless failover, the LACP state on
the redundant Ethernet interface standby links must be collected and distributed before failover occurs.
310

Managing Link Aggregation Control PDUs

The protocol data units (PDUs) contain information about the state of the link. By default, aggregated
and redundant Ethernet links do not exchange link aggregation control PDUs.

You can configure PDUs exchange in the following ways:

• Configure Ethernet links to actively transmit link aggregation control PDUs

• Configure Ethernet links to passively transmit PDUs, sending out link aggregation control PDUs only
when they are received from the remote end of the same link

The local end of a child link is known as the actor and the remote end of the link is known as the partner.
That is, the actor sends link aggregation control PDUs to its protocol partner that convey what the actor
knows about its own state and that of the partner’s state.

You configure the interval at which the interfaces on the remote side of the link transmit link
aggregation control PDUs by configuring the periodic statement on the interfaces on the local side. It is
the configuration on the local side that specifies the behavior of the remote side. That is, the remote
side transmits link aggregation control PDUs at the specified interval. The interval can be fast (every
second) or slow (every 30 seconds).

For more information, see "Example: Configuring LACP on Chassis Clusters" on page 310.

By default, the actor and partner transmit link aggregation control PDUs every second. You can
configure different periodic rates on active and passive interfaces. When you configure the active and
passive interfaces at different rates, the transmitter honors the receiver’s rate.

Example: Configuring LACP on Chassis Clusters

IN THIS SECTION

Requirements | 311

Overview | 311

Configuration | 312

Verification | 318

This example shows how to configure LACP on chassis clusters.


311

Requirements
Before you begin:

Complete the tasks such as enabling the chassis cluster, configuring interfaces and redundancy groups.
See "SRX Series Chassis Cluster Configuration Overview" on page 13 and "Example: Configuring Chassis
Cluster Redundant Ethernet Interfaces" on page 103 for more details.

Overview
You can combine multiple physical Ethernet ports to form a logical point-to-point link, known as a link
aggregation group (LAG) or bundle. You configure LACP on a redundant Ethernet interface of SRX Series
Firewall in chassis cluster.

In this example, you set the LACP mode for the reth1 interface to active and set the link aggregation
control PDU transmit interval to slow, which is every 30 seconds.

When you enable LACP, the local and remote sides of the aggregated Ethernet links exchange protocol
data units (PDUs), which contain information about the state of the link. You can configure Ethernet
links to actively transmit PDUs, or you can configure the links to passively transmit them (sending out
LACP PDUs only when they receive them from another link). One side of the link must be configured as
active for the link to be up.

Figure 37 on page 311 shows the topology used in this example.

Figure 37: Topology for LAGs Connecting SRX Series Firewalls in Chassis Cluster to an EX Series Switch

In the Figure 37 on page 311, SRX550 devices are used to configure the interfaces on node0 and node1.
For more information on EX Series switch configuration, see Configuring Aggregated Ethernet LACP (CLI
Procedure).
312

Configuration

IN THIS SECTION

Configuring LACP on Chassis Cluster | 312

Configuring LACP on EX Series Switch | 314

Configuring LACP on Chassis Cluster

Step-by-Step Procedure

To configure LACP on chassis clusters:

1. Specify the number of redundant Ethernet interfaces.

[edit chassis cluster]


user@host# set reth-count 2

2. Specify a redundancy group's priority for primacy on each node of the cluster. The higher number
takes precedence.

[edit chassis cluster]


user@host# set redundancy-group 1 node 0 priority 200
user@host# set redundancy-group 1 node 1 priority 100

3. Create security zone and assign interfaces to zone.

[edit security zones]


user@host# set security-zone trust host-inbound-traffic system-services all
user@host# set security-zone trust interfaces reth1.0

4. Bind redundant child physical interfaces to reth1.

[edit interfaces]
user@host# set ge-0/0/4 gigether-options redundant-parent reth1
user@host# set ge-0/0/5 gigether-options redundant-parent reth1
313

user@host# set ge-9/0/4 gigether-options redundant-parent reth1


user@host# set ge-9/0/5 gigether-options redundant-parent reth1

5. Add reth1 to redundancy group 1.

[edit interfaces]
user@host# set reth1 redundant-ether-options redundancy-group 1

6. Set the LACP on reth1.

[edit interfaces]
user@host# set reth1 redundant-ether-options lacp active
user@host# set reth1 redundant-ether-options lacp periodic slow

7. Assign an IP address to reth1.

[edit interfaces]
user@host# set reth1 unit 0 family inet address 192.168.2.1/24

8. Configure LACP on aggregated Ethernet interfaces (ae1).

9. Configure LACP on aggregated Ethernet interfaces (ae2).

10. If you are done configuring the device, commit the configuration.

[edit interfaces]
user@host# commit

Results

From configuration mode, confirm your configuration by entering the show chassis, show security zones, and
show interfaces commands. If the output does not display the intended configuration, repeat the
configuration instructions in this example to correct it.

[edit]
user@host#show chassis
cluster {
reth-count 2;
314

redundancy-group 1 {
node 0 priority 200;
node 1 priority 100;
}
}
[edit]
user@host#show security zones
security-zone trust {
host-inbound-traffic {
system-services {
all;
}
}
interfaces {
reth1.0;
}
}
[edit]
user@host#show interfaces
reth1 {
redundant-ether-options {
redundancy-group 1;
lacp {
active;
periodic slow;
}
}
unit 0 {
family inet {
address 192.168.2.1/24;
}
}
}

Configuring LACP on EX Series Switch

Step-by-Step Procedure

Configure LACP on EX Series switch.


315

1. Set the number of aggregated Ethernet interfaces.

[edit chassis]
user@host# set aggregated-devices ethernet device-count 3

2. Associate physical interfaces with aggregated Ethernet interfaces.

[edit interfaces]
user@host# set ge-0/0/1 gigether-options 802.3ad ae1
user@host# set ge-0/0/2 gigether-options 802.3ad ae1
user@host# set ge-0/0/3 gigether-options 802.3ad ae2
user@host# set ge-0/0/4 gigether-options 802.3ad ae2

3. Configure LACP on aggregated Ethernet interfaces (ae1).

[edit interfaces]
user@host# set interfaces ae1 unit 0 family ethernet-switching interface-mode access

user@host# set interfaces ae1 unit 0 family ethernet-switching vlan members RETH0_VLAN

4. Configure LACP on aggregated Ethernet interfaces (ae2).

[edit interfaces]

user@host# set interfaces ae2 unit 0 family ethernet-switching interface-mode access

user@host# set interfaces ae2 unit 0 family ethernet-switching vlan members RETH0_VLAN

5. Configure VLAN.

user@host#set vlans RETH0_VLAN vlan-id 10


user@host# set vlans RETH0_VLAN l3-interface vlan.10
user@host# set interfaces vlan unit 10 family inet address 192.168.2.254/24
316

Results

From configuration mode, confirm your configuration by entering the show chassis and show interfaces
commands. If the output does not display the intended configuration, repeat the configuration
instructions in this example to correct it.

[edit]
user@host# show chassis
aggregated-devices {
ethernet {
device-count 3;
}
}
user@host# show vlans
RETH0_VLAN {
vlan-id 10;
l3-interface vlan.10;
}
user@host> show vlans RETH0_VLAN
Routing instance VLAN name Tag Interfaces
default-switch RETH0_VLAN 10
ae1.0*
ae2.0*
user@host> show ethernet-switching interface ae1
Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown,
SCTL - shutdown by Storm-control )
Logical Vlan TAG MAC STP Logical Tagging
interface members limit state interface flags
ae1.0 131072 untagged
RETH0_VLAN 10 131072 Forwarding untagged
user@host> show ethernet-switching interface ae2
Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown,
SCTL - shutdown by Storm-control )

Logical Vlan TAG MAC STP Logical Tagging


interface members limit state interface flags
317

ae2.0 131072 untagged


RETH0_VLAN 10 131072 Forwarding untagged
user@host# show interfaces
ge-0/0/1 {
ether-options {
802.3ad ae1;
}
}
ge-0/0/2 {
ether-options {
802.3ad ae1;
}
}
ge-0/0/3 {
ether-options {
802.3ad ae2;
}
}
ge-0/0/4 {
ether-options {
802.3ad ae2;
}
}
ae1 {
aggregated-ether-options {
lacp {
active;
periodic slow;
}
}
unit 0 {
family ethernet-switching {
interface-mode access;
vlan {
members RETH0_VLAN;
}
}
}
}
ae2 {
aggregated-ether-options {
lacp {
active;
318

periodic slow;
}
}
unit 0 {
family ethernet-switching {
interface-mode access;
vlan {
members RETH0_VLAN;
}
}
}
}
vlan {
unit 10 {
family inet {
address 192.168.2.254/24 {
}
}
}

Verification

IN THIS SECTION

Verifying LACP on Redundant Ethernet Interfaces | 318

Verifying LACP on Redundant Ethernet Interfaces

Purpose

Display LACP status information for redundant Ethernet interfaces.


319

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}[edit]
user@host> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring RE Relinquish monitoring
IS IRQ storm

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 1 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 1


node0 200 primary no no None
node1 100 secondary no no None

{primary:node0}[edit]
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 fxp1 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 ge-0/0/2 Up / Up Enabled
320

fab0
fab1 ge-9/0/2 Up / Up Enabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Up 1

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

From operational mode, enter the show lacp interfaces reth1 command.

{primary:node0}[edit]
user@host> show lacp interfaces reth1
Aggregated interface: reth1
LACP state: Role Exp Def Dist Col Syn Aggr Timeout Activity
ge-0/0/4 Actor No No Yes Yes Yes Yes Slow Active
ge-0/0/4 Partner No No Yes Yes Yes Yes Slow Active
ge-0/0/5 Actor No No Yes Yes Yes Yes Slow Active
ge-0/0/5 Partner No No Yes Yes Yes Yes Slow Active
ge-9/0/4 Actor No No Yes Yes Yes Yes Slow Active
ge-9/0/4 Partner No No Yes Yes Yes Yes Slow Active
ge-9/0/5 Actor No No Yes Yes Yes Yes Slow Active
ge-9/0/5 Partner No No Yes Yes Yes Yes Slow Active
LACP protocol: Receive State Transmit State Mux State
ge-0/0/4 Current Slow periodic Collecting distributing
ge-0/0/5 Current Slow periodic Collecting distributing
ge-9/0/4 Current Slow periodic Collecting distributing
ge-9/0/5 Current Slow periodic Collecting distributing

The output shows redundant Ethernet interface information, such as the following:

• The LACP state—Indicates whether the link in the bundle is an actor (local or near-end of the link) or
a partner (remote or far-end of the link).

• The LACP mode—Indicates whether both ends of the aggregated Ethernet interface are enabled
(active or passive)—at least one end of the bundle must be active.

• The periodic link aggregation control PDU transmit rate.


321

• The LACP protocol state—Indicates the link is up if it is collecting and distributing packets.

Example: Configuring Chassis Cluster Minimum Links

IN THIS SECTION

Requirements | 321

Overview | 321

Configuration | 322

Verification | 322

This example shows how to specify a minimum number of physical links assigned to a redundant
Ethernet interface on the primary node that must be working for the interface to be up.

Requirements
Before you begin:

• Configure redundant Ethernet interfaces. See "Example: Configuring Chassis Cluster Redundant
Ethernet Interfaces" on page 103.

• Understand redundant Ethernet interface link aggregation groups. See "Example: Configuring Link
Aggregation Groups in a Chassis Cluster" on page 300.

Overview

When a redundant Ethernet interface has more than two child links, you can set a minimum number of
physical links assigned to the interface on the primary node that must be working for the interface to be
up. When the number of physical links on the primary node falls below the minimum-links value, the
interface will be down even if some links are still working.

In this example, you specify that three child links on the primary node and bound to reth1 (minimum-
links value) be working to prevent the interface from going down. For example, in a redundant Ethernet
interface LAG configuration in which six interfaces are assigned to reth1, setting the minimum-links
value to 3 means that all reth1 child links on the primary node must be working to prevent the
interface’s status from changing to down.
322

Although it is possible to set a minimum-links value for a redundant Ethernet interface with only two
child interfaces (one on each node), we do not recommend it.

Configuration

IN THIS SECTION

Procedure | 322

Procedure

Step-by-Step Procedure

To specify the minimum number of links:

1. Specify the minimum number of links for the redundant Ethernet interface.

{primary:node0}[edit]
user@host# set interfaces reth1 redundant-ether-options minimum-links 3

2. If you are done configuring the device, commit the configuration.

{primary:node0}[edit]
user@host# commit

Verification

IN THIS SECTION

Verifying the Chassis Cluster Minimum Links Configuration | 323


323

Verifying the Chassis Cluster Minimum Links Configuration

Purpose

To verify the configuration is working properly, enter the show interface reth1 command.

Action

From operational mode, enter the show show interfaces reth1 command.

{primary:node0}[edit]
user@host> show interfaces reth1
Physical interface: reth1, Enabled, Physical link is Down
Interface index: 129, SNMP ifIndex: 548
Link-level type: Ethernet, MTU: 1514, Speed: Unspecified, BPDU Error: None,
MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled,
Flow control: Disabled, Minimum links needed: 3, Minimum bandwidth needed: 0
Device flags : Present Running
Interface flags: Hardware-Down SNMP-Traps Internal: 0x0
Current address: 00:10:db:ff:10:01, Hardware address: 00:10:db:ff:10:01
Last flapped : 2010-09-15 15:54:53 UTC (1w0d 22:07 ago)
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)

Logical interface reth1.0 (Index 68) (SNMP ifIndex 550)


Flags: Hardware-Down Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Statistics Packets pps Bytes bps
Bundle:
Input : 0 0 0 0
Output: 0 0 0 0
Security: Zone: untrust
Allowed host-inbound traffic : bootp bfd bgp dns dvmrp igmp ldp msdp nhrp
ospf pgm pim rip router-discovery rsvp sap vrrp dhcp finger ftp tftp
ident-reset http https ike netconf ping reverse-telnet reverse-ssh rlogin
rpm rsh snmp snmp-trap ssh telnet traceroute xnm-clear-text xnm-ssl lsping
ntp sip
Protocol inet, MTU: 1500
Flags: Sendbcast-pkt-to-re
324

Example: Configuring Chassis Cluster Redundant Ethernet Interface Link


Aggregation Groups on an SRX5000 Line Device with IOC2 or IOC3

IN THIS SECTION

Requirements | 324

Overview | 324

Configuration | 325

Verification | 328

Support for Ethernet link aggregation groups (LAGs) based on IEEE 802.3ad makes it possible to
aggregate physical interfaces on a standalone device. LAGs on standalone devices provide increased
interface bandwidth and link availability. Aggregation of links in a chassis cluster allows a redundant
Ethernet interface to add more than two physical child interfaces, thereby creating a redundant Ethernet
interface LAG.

Requirements
This example uses the following software and hardware components:

• Junos OS Release 15.1X49-D40 or later for SRX Series Firewalls.

• SRX5800 with IOC2 or IOC3 with Express Path enabled on IOC2 and IOC3. For details, see Example:
Configuring SRX5K-MPC3-100G10G (IOC3) and SRX5K-MPC3-40G10G (IOC3) on an SRX5000 Line
Device to Support Express Path.

Overview
This example shows how to configure a redundant Ethernet interface link aggregation group and
configure LACP on chassis clusters on an SRX Series Firewall using the ports from either IOC2 or IOC3
in Express Path mode. Note that configuring child interfaces by mixing links from both IOC2 and IOC3 is
not supported.

The following member links are used in this example:

• xe-1/0/0

• xe-3/0/0

• xe-14/0/0
325

• xe-16/0/0

Configuration

IN THIS SECTION

CLI Quick Configuration | 325

Procedure | 325

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, delete, and then copy
and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from
configuration mode.

set chassis cluster reth-count 5


set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 redundant-ether-options lacp active
set interfaces reth0 redundant-ether-options lacp periodic fast
set interfaces reth0 redundant-ether-options minimum-links 1
set interfaces reth0 unit 0 family inet address 192.0.2.1/24
set interfaces xe-1/0/0 gigether-options redundant-parent reth0
set interfaces xe-3/0/0 gigether-options redundant-parent reth0
set interfaces xe-14/0/0 gigether-options redundant-parent reth0
set interfaces xe-16/0/0 gigether-options redundant-parent reth0

Procedure

Step-by-Step Procedure

To configure LAG Interfaces:

1. Specify the number of aggregated Ethernet interfaces to be created.

[edit chassis]
user@host# set chassis cluster reth-count 5
326

2. Bind redundant child physical interfaces to reth0.

[edit interfaces]
user@host# set xe-1/0/0 gigether-options redundant-parent reth0
user@host# set xe-3/0/0 gigether-options redundant-parent reth0
user@host# set xe-14/0/0 gigether-options redundant-parent reth0
user@host# set xe-16/0/0 gigether-options redundant-parent reth0

3. Add reth0 to redundancy group 1.

user@host#set reth0 redundant-ether-options redundancy-group 1

4. Assign an IP address to reth0.

[edit interfaces]
user@host# set reth0 unit 0 family inet address 192.0.2.1/24

5. Set the LACP on reth0.

[edit interfaces]
user@host# set reth0 redundant-ether-options lacp active
user@host# set reth0 redundant-ether-options lacp periodic fast
user@host# set reth0 redundant-ether-options minimum-links 1

Results

From configuration mode, confirm your configuration by entering the show interfaces command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

[edit]
user@host# show interfaces
xe-1/0/0 {
gigether-options {
redundant-parent reth0;
}
}
xe-3/0/0 {
327

gigether-options {
redundant-parent reth0;
}
}
xe-14/0/0 {
gigether-options {
redundant-parent reth0;
}
}
xe-16/0/0 {
gigether-options {
redundant-parent reth0;
}
}
reth0 {
redundant-ether-options {
lacp {
active;
periodic fast;
}
minimum-links 1;
}
unit 0 {
family inet {
address 192.0.2.1/24;
}
}
}
ae1 {
aggregated-ether-options {
lacp {
active;
}
}
unit 0 {
family inet {
address 192.0.2.2/24;
}
328

}
}

[edit]
user@host# show chassis
chassis cluster {
reth-count 5;
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying LACP on Redundant Ethernet Interfaces | 328

Verifying LACP on Redundant Ethernet Interfaces

Purpose

Display LACP status information for redundant Ethernet interfaces.

Action

From operational mode, enter the show lacp interfaces command to check that LACP has been enabled as
active on one end.

user@host> show lacp interfaces

Aggregated interface: reth0


LACP state: Role Exp Def Dist Col Syn Aggr Timeout Activity
xe-16/0/0 Actor No No Yes Yes Yes Yes Fast Active
xe-16/0/0 Partner No No Yes Yes Yes Yes Fast Active
xe-14/0/0 Actor No No Yes Yes Yes Yes Fast Active
xe-14/0/0 Partner No No Yes Yes Yes Yes Fast Active
xe-1/0/0 Actor No No Yes Yes Yes Yes Fast Active
329

xe-1/0/0 Partner No No Yes Yes Yes Yes Fast Active


xe-3/0/0 Actor No No Yes Yes Yes Yes Fast Active
xe-3/0/0 Partner No No Yes Yes Yes Yes Fast Active
LACP protocol: Receive State Transmit State Mux State
xe-16/0/0 Current Fast periodic Collecting distributing
xe-14/0/0 Current Fast periodic Collecting distributing
xe-1/0/0 Current Slow periodic Collecting distributing
xe-3/0/0 Current Slow periodic Collecting distributing

The output indicates that LACP has been set up correctly and is active at one end.

Understanding VRRP on SRX Series Firewalls

IN THIS SECTION

Overview of VRRP on SRX Series Firewalls | 329

Benefits of VRRP | 330

Sample VRRP Topology | 330

SRX Series Firewalls Support for VRRPv3 | 331

Limitations of VRRPv3 Features | 332

SRX Series Firewalls support the Virtual Router Redundancy Protocol (VRRP) and VRRP for IPv6. This
topic covers:

Overview of VRRP on SRX Series Firewalls

Configuring end hosts on your network with static default routes minimizes configuration effort and
complexity and reduces processing overhead on the end hosts. When hosts are configured with static
routes, the failure of the default gateway normally results in a catastrophic event, isolating all hosts that
are unable to detect available alternate paths to their gateway. Using Virtual Router Redundancy
Protocol (VRRP) enables you to dynamically provide alternative gateways for end hosts if the primary
gateway fails.

You can configure the Virtual Router Redundancy Protocol (VRRP) or VRRP for IPv6 on Gigabit Ethernet
interfaces, 10-Gigabit Ethernet interfaces, and logical interfaces on SRX Series Firewalls. VRRP enables
hosts on a LAN to make use of redundant devices on that LAN without requiring more than the static
330

configuration of a single default route on the hosts. Devices configured with VRRP share the IP address
corresponding to the default route configured on the hosts. At any time, one of the VRRP configured
devices is the primary (active) and the others are backups. If the primary device fails, then one of the
backup devices becomes the new primary, providing a virtual default device and enabling traffic on the
LAN to be routed without relying on a single device. Using VRRP, a backup SRX Series Firewall can take
over a failed default device within a few seconds. This is done with minimum loss of VRRP traffic and
without any interaction with the hosts. Virtual Router Redundancy Protocol is not supported on
management interfaces.

VRRP for IPv6 provides a much faster switchover to an alternate default device than IPv6 Neighbor
Discovery (ND) procedures. VRRP for IPv6 does not support the authentication-type or authentication-key
statements.

Devices running VRRP dynamically elect primary and backup devices. You can also force assignment of
primary and backup devices using priorities from 1 through 255, with 255 being the highest priority. In
VRRP operation, the default primary device sends advertisements to the backup device at a regular
intervals. The default interval is 1 second. If the backup device do not receive an advertisement for a set
period, then the backup device with the highest priority takes over as primary and begins forwarding
packets.

The backup devices do not attempt to preempt the primary device unless it has higher priority. This
eliminates service disruption unless a more preferred path becomes available. It is possible to
administratively prohibit all preemption attempts, with the exception of a VRRP device becoming
primary device of any device associated with addresses it owns.

VRRP does not support session synchronization between members. If the primary device fails, the
backup device with the highest priority takes over as primary and will begin forwarding packets. Any
existing sessions will be dropped on the backup device as out-of-state.

Priority 255 cannot be set for routed VLAN interfaces (RVIs).

VRRP is defined in RFC 3768, Virtual Router Redundancy Protocol.

Benefits of VRRP

• VRRP provides dynamic failover of IP addresses from one device to another in the event of failure.

• You can implement VRRP to provide a highly available default path to a gateway without needing to
configure dynamic routing or router discovery protocols on end hosts.

Sample VRRP Topology

Figure 38 on page 331 illustrates a basic VRRP topology with SRX Series Firewalls. In this example,
Devices A and B are running VRRP and share the virtual IP address 192.0.2.1. The default gateway for
each of the clients is 192.0.2.1.
331

Figure 38: Basic VRRP on SRX Series Switches

The following illustrates basic VRRP behavior using Figure 38 on page 331 for reference:

1. When any of the servers wants to send traffic out of the LAN, it sends the traffic to the default
gateway address of 192.0.2.1. This is a virtual IP address (VIP) owned by VRRP group 100. Because
Device A is the primary of the group, the VIP is associated with the “real” address 192.0.2.251 on
Device A, and traffic from the servers is actually sent to this address. (Device A is the primary
because it has been configured with a higher priority value.)

2. If there is a failure on Device A that prevents it from forwarding traffic to or from the servers—for
example, if the interface connected to the LAN fails—Device B becomes the primary and assumes
ownership of the VIP. The servers continue to send traffic to the VIP, but because the VIP is now
associated with the “real” address 192.0.2.252 on Device B (because of change of primary), the traffic
is sent to Device B instead of Device A.

3. If the problem that caused the failure on Device A is corrected, Device A becomes the primary again
and reasserts ownership of the VIP. In this case, the servers resume sending traffic to Device A.

Notice that no configuration changes are required on the servers for them to switch between sending
traffic to Device A and Device B. When the VIP moves between 192.0.2.251 and 192.0.2.252, the
change is detected by normal TCP-IP behavior and no configuration or intervention is required on the
servers.

SRX Series Firewalls Support for VRRPv3

The advantage of using VRRPv3 is that VRRPv3 supports both IPv4 and IPv6 address families, whereas
VRRP supports only IPv4 addresses.

Enable VRRPv3 in your network only if VRRPv3 can be enabled on all the devices configured with VRRP
in your network because VRRPv3 (IPv4) does not interoperate with the previous versions of VRRP. For
example, if VRRP IPv4 advertisement packets are received by a device on which VRRPv3 is enabled,
then the device transitions itself to the backup state to avoid creating multiple primaries in the network.
332

You can enable VRRPv3 by configuring the version-3 statement at the [edit protocols vrrp] hierarchy
level (for IPv4 or IPv6 networks). Configure the same protocol version on all VRRP devices on the LAN.

Limitations of VRRPv3 Features

Below are some VRRPv3 features limitations.

VRRPv3 Authentication

When VRRPv3 (for IPv4) is enabled, it does not allow authentication.

• The authentication-type and authentication-key statements cannot be configured for any VRRP groups.

• You must use non-VRRP authentication.

VRRPv3 Advertisement Intervals

VRRPv3 (for IPv4 and IPv6) advertisement intervals must be set with the fast-interval statement at the
[edit interfaces interface-name unit 0 family inet address ip-address vrrp-group group-name] hierarchy
level.

• Do not use the advertise-interval statement (for IPv4).

• Do not use the inet6-advertise-interval statement (for IPv6).

SEE ALSO

Junos OS High Availability Configuration Guide


show vrrp | 984

VRRP failover-delay Overview

IN THIS SECTION

When failover-delay Is Not Configured | 333

When failover-delay Is Configured | 334


333

Failover is a backup operational mode in which the functions of a network device are assumed by a
secondary device when the primary device becomes unavailable because of a failure or a scheduled
down time. Failover is typically an integral part of mission-critical systems that must be constantly
available on the network.

VRRP does not support session synchronization between members. If the primary device fails, the
backup device with the highest priority takes over as primary and will begin forwarding packets. Any
existing sessions will be dropped on the backup device as out-of-state.

A fast failover requires a short delay. Thus, failover-delay configures the failover delay time, in
milliseconds, for VRRP and VRRP for IPv6 operations. Junos OS supports a range of 50 through 100000
milliseconds for delay in failover time.

The VRRP process (vrrpd) running on the Routing Engine communicates a VRRP primary role change to
the Packet Forwarding Engine for every VRRP session. Each VRRP group can trigger such
communication to update the Packet Forwarding Engine with its own state or the state inherited form
an active VRRP group. To avoid overloading the Packet Forwarding Engine with such messages, you can
configure a failover-delay to specify the delay between subsequent Routing Engine to Packet
Forwarding Engine communications.

The Routing Engine communicates a VRRP primary role change to the Packet Forwarding Engine to
facilitate necessary state change on the Packet Forwarding Engine, such as reprogramming of Packet
Forwarding Engine hardware filters, VRRP sessions and so on. The following sections elaborate the
Routing Engine to Packet Forwarding Engine communication in two scenarios:

When failover-delay Is Not Configured

Without failover-delay configured, the sequence of events for VRRP sessions operated from the Routing
Engine is as follows:

1. When the first VRRP group detected by the Routing Engine changes state, and the new state is
primary, the Routing Engine generates appropriate VRRP announcement messages. The Packet
Forwarding Engine is informed about the state change, so that hardware filters for that group are
reprogrammed without delay. The new primary then sends gratuitous ARP message to the VRRP
groups.

2. The delay in failover timer starts. By default, failover-delay timer is:

• 500 miliseconds—when the configured VRRP announcement interval is less than 1 second.

• 2 seconds—when the configured VRRP announcement interval is 1 second or more, and the total
number of VRRP groups on the router is 255.

• 10 seconds—when the configured VRRP announcement interval is 1 second or more, and the
number of VRRP groups on the router is more than 255.
334

3. The Routing Engine performs one-by-one state change for subsequent VRRP groups. Every time
there is a state change, and the new state for a particular VRRP group is primary, the Routing Engine
generates appropriate VRRP announcement messages. However, communication toward the Packet
Forwarding Engine is suppressed until the failover-delay timer expires.

4. After failover-delay timer expires, the Routing Engine sends message to the Packet Forwarding
Engine about all VRRP groups that managed to change the state. As a consequence, hardware filters
for those groups are reprogrammed, and for those groups whose new state is primary, gratuitous
ARP messages are sent.

This process repeats until state transition for all VRRP groups is complete.

Thus, without configuring failover-delay, the full state transition (including states on the Routing Engine
and the Packet Forwarding Engine) for the first VRRP group is performed immediately, while state
transition on the Packet Forwarding Engine for remaining VRRP groups is delayed by at least 0.5-10
seconds, depending on the configured VRRP announcement timers and the number of VRRP groups.
During this intermediate state, receiving traffic for VRRP groups for state changes that were not yet
completed on the Packet Forwarding Engine might be dropped at the Packet Forwarding Engine level
due to deferred reconfiguration of hardware filters.

When failover-delay Is Configured

When failover-delay is configured, the sequence of events for VRRP sessions operated from the Routing
Engine is modified as follows:

1. The Routing Engine detects that some VRRP groups require a state change.

2. The failover-delay starts for the period configured. The allowed failover-delay timer range is 50
through 100000 miliseconds.

3. The Routing Engine performs one-by-one state change for the VRRP groups. Every time there is a
state change, and the new state for a particular VRRP group is primary, the Routing Engine generates
appropriate VRRP announcement messages. However, communication toward the Packet Forwarding
Engine is suppressed until the failover-delay timer expires.

4. After failover-delay timer expires, the Routing Enigne sends message to the Packet Forwarding
Engine about all VRRP groups that managed to change the state. As a consequence, hardware filters
for those groups are reprogrammed, and for those groups whose new state is primary, gratuitous
ARP messages are sent.

This process repeats until state transition for all VRRP groups is complete.

Thus, when failover-delay is configured even the Packet Forwarding Engine state for the first VRRP
group is deferred. However, the network operator has the advantage of configuring a failover-delay
value that best suits the need of the network deployment to ensure minimal outage during VRRP state
change.
335

failover-delay influences only VRRP sessions operated by the VRRP process (vrrpd) running on the
Routing Engine. For VRRP sessions distributed to the Packet Forwarding Engine, failover-delay
configuration has no effect.

SEE ALSO

failover-delay

Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant


Ethernet Interfaces

IN THIS SECTION

Requirements | 335

Overview | 336

Configuration VRRP | 337

Verification | 344

When Virtual Router Redundancy Protocol (VRRP) is configured, the VRRP groups multiple devices into
a virtual device. At any time, one of the devices configured with VRRP is the primary (active) and the
other devices are backups. If the primary fails, one of the backup devices becomes the new primary
device.

This example describes how to configure VRRP on redundant interface:

Requirements
This example uses the following hardware and software components:

• Junos OS Release 18.1 R1 or later for SRX Series Firewalls.

• Two SRX Series Firewalls connected in a chassis cluster.

• One SRX Series Firewall connected as standalone device.


336

Overview

IN THIS SECTION

Topology | 336

You configure VRRP by configuring VRRP groups on redundant interfaces on a chassis cluster devices
and on Gigabit Ethernet interface on standalone device. A redundant interface of chassis cluster devices
and Gigabit Ethernet interface of standalone device can be a member of one or more VRRP groups.
Within a VRRP group, the primary redundant interface of chassis cluster devices and the backup Gigabit
Ethernet interface of standalone device must be configured.

To configure VRRP group, you must configure group identifier, and virtual IP address to the redundant
interfaces and Gigabit Ethernet interfaces that are members of VRRP group. The virtual IP address must
be the same for all the interfaces in the VRRP group. Then you configure the priority to the redundant
interfaces and Gigabit Ethernet interfaces to become the primary interface.

You can force assignment of primary and backup redundant interfaces and Gigabit Ethernet interfaces
using priorities from 1 through 255, where 255 is the highest priority.

Topology

Figure 39 on page 336 shows the topology used in this example.

Figure 39: VRRP on Redundant interface


337

Configuration VRRP

IN THIS SECTION

Configuring VRRPv3, VRRP Groups, and Priority on Chassis Cluster Redundant Ethernet
Interfaces | 337

Configuring VRRP Groups on Standalone Device | 342

Configuring VRRPv3, VRRP Groups, and Priority on Chassis Cluster Redundant Ethernet Interfaces

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

set protocols vrrp traceoptions file vrrp.log


set protocols vrrp traceoptions file size 10000000
set protocols vrrp traceoptions flag all
set protocols vrrp version-3
set protocols vrrp ignore-nonstop-routing
set interfaces ge-0/0/0 gigether-options redundant-parent reth0
set interfaces ge-0/0/3 gigether-options redundant-parent reth1
set interfaces ge-5/0/0 gigether-options redundant-parent reth0
set interfaces ge-5/0/3 gigether-options redundant-parent reth1
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 family inet address 192.0.2.2/24 vrrp-group 0 virtual-address 192.0.2.3
set interfaces reth0 unit 0 family inet address 192.0.2.2/24 vrrp-group 0 priority 255
set interfaces reth0 unit 0 family inet address 192.0.2.2/24 vrrp-group 0 accept-data
set interfaces reth0 unit 0 family inet6 address 2001:db8::2/32 vrrp-inet6-group 2 virtual-inet6-address
2001:db8::3
set interfaces reth0 unit 0 family inet6 address 2001:db8::2/32 vrrp-inet6-group 2 priority 255
set interfaces reth0 unit 0 family inet6 address 2001:db8::2/32 vrrp-inet6-group 2 accept-data
set interfaces reth1 redundant-ether-options redundancy-group 2
set interfaces reth1 unit 0 family inet address 192.0.2.4/24 vrrp-group 1 virtual-address 192.168.120.3
set interfaces reth1 unit 0 family inet address 192.0.2.4/24 vrrp-group 1 priority 150
set interfaces reth1 unit 0 family inet address 192.0.2.4/24 vrrp-group 1 accept-data
set interfaces reth1 unit 0 family inet6 address 2001:db8::3/32 vrrp-inet6-group 3 virtual-inet6-address
2001:db8::4
338

set interfaces reth1 unit 0 family inet6 address 2001:db8::3/32 vrrp-inet6-group 3 priority 150
set interfaces reth1 unit 0 family inet6 address 2001:db8::3/32 vrrp-inet6-group 3 accept-data

Step-by-Step Procedure

To configure VRRPv3, VRRP Groups, and priority on chassis cluster devices:

1. Configure a filename to the traceoptions to trace VRRP protocol traffic.

[edit protocols vrrp]


user@host# set traceoptions file vrrp.log

2. Specify the maximum trace file size.

[edit protocols vrrp]


user@host# set traceoptions file size 10000000

3. Enable vrrp traceoptions.

[edit protocols vrrp]


user@host# set traceoptions flag all

4. Set vrrp version to 3.

[edit protocols vrrp]


user@host# set version-3

5. Configure this command to support graceful Routing Engine switchover (GRES) for VRRP and for
nonstop active routing when there is VRRP reth failover. Using vrrp, a secondary node can take
over a failed primary node within a few seconds and this is done with minimum VRRP traffic and
without any interaction with the hosts

[edit protocols vrrp]


user@host#set ignore-nonstop-routing
339

6. Set up the redundant Ethernet (reth) interfaces and assign the redundant interface to a zone.

[edit interfaces]
user@host# set ge-0/0/0 gigether-options redundant-parent reth0
user@host# set ge-0/0/3 gigether-options redundant-parent reth1
user@host# set ge-5/0/0 gigether-options redundant-parent reth0
user@host# set ge-5/0/3 gigether-options redundant-parent reth1
user@host# set reth0 redundant-ether-options redundancy-group 1
user@host# set reth1 redundant-ether-options redundancy-group 2

7. Configure the family inet address and virtual address for the redundant interface 0 unit 0.

[edit interfaces]
user@host# set reth0 unit 0 family inet address 192.0.2.2/24 vrrp-group 0 virtual-address
192.168.110.3
user@host# set reth0 unit 0 family inet6 address 2001:db8::2/32 vrrp-inet6-group 2 virtual-inet6-
address 2001:db8::3

8. Configure the family inet address and virtual address for the redundant interface 1 unit 0.

[edit interfaces]
user@host# set reth1 unit 0 family inet address 192.0.2.4/24 vrrp-group 1 virtual-address
192.168.120.3
user@host# set reth1 unit 0 family inet6 address 2001:db8::3/32 vrrp-inet6-group 3 virtual-inet6-
address 2001:db8::4

9. Set the priority of the redundant interface 0 unit 0 to 255.

[edit interfaces]
user@host# set reth0 unit 0 family inet address 192.0.2.2/24 vrrp-group 0 priority 255
user@host# set reth0 unit 0 family inet6 address 2001:db8::2/32 vrrp-inet6-group 2 priority 255

10. Set the priority of the redundant interface 1 unit 0 to 150.

[edit interfaces]
user@host# set reth1 unit 0 family inet address 192.0.2.4/24 vrrp-group 1 priority 150
user@host# set reth1 unit 0 family inet6 address 2001:db8::3/32 vrrp-inet6-group 3 priority 150
340

11. Configure the redundant interface 0 unit 0 to accept all packets sent to the virtual IP address.

[edit interfaces]
user@host# set reth0 unit 0 family inet address 192.0.2.2/24 vrrp-group 0 accept-data
user@host# set reth0 unit 0 family inet6 address 2001:db8::2/32 vrrp-inet6-group 2 accept-data

12. Configure the redundant interface 1 unit 0 to accept all packets sent to the virtual IP address.

[edit interfaces]
user@host# set reth1 unit 0 family inet address 192.0.2.4/24 vrrp-group 1 accept-data
user@host# set reth1 unit 0 family inet6 address 2001:db8::3/32 vrrp-inet6-group 3 accept-data

Results

From configuration mode, confirm your configuration by entering the show interfaces reth0 and show
interfaces reth1 commands. If the output does not display the intended configuration, repeat the
configuration instructions in this example to correct it.

[edit]
user@host# show interfaces reth0
redundant-ether-options {
redundancy-group 1;
}
unit 0 {
family inet {
address 192.0.2.2/24 {
vrrp-group 0 {
virtual-address 192.0.2.3;
priority 255;
accept-data;
}
}
}
family inet6 {
address 2001:db8::2/32 {
vrrp-inet6-group 2 {
virtual-inet6-address 2001:db8::3;
priority 255;
accept-data;
341

}
}
}
}

[edit]
user@host# show interfaces reth1
redundant-ether-options {
redundancy-group 2;
}
unit 0 {
family inet {
address 192.0.2.4/24 {
vrrp-group 1 {
virtual-address
192.0.2.5;
priority 150;
accept-data;
}
}
}
family inet6 {
address 2001:db8::3/32
{
vrrp-inet6-group 3
{
virtual-inet6-address
2001:db8::4;
priority
150;
accept-
data;
}

}
}

If you are done configuring the device, enter commit from configuration mode.
342

Configuring VRRP Groups on Standalone Device

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

set protocols vrrp version-3


set interfaces xe-5/0/5 unit 0 family inet address 192.0.2.1/24 vrrp-group 0 virtual-address 192.0.2.3
set interfaces xe-5/0/5 unit 0 family inet address 192.0.2.1/24 vrrp-group 0 priority 50
set interfaces xe-5/0/5 unit 0 family inet address 192.0.2.1/24 vrrp-group 0 accept-data
set interfaces xe-5/0/5 unit 0 family inet6 address 2001:db8::1/32 vrrp-inet6-group 2 virtual-inet6-address
2001:db8::3
set interfaces xe-5/0/5 unit 0 family inet6 address 2001:db8::1/32 vrrp-inet6-group 2 priority 50
set interfaces xe-5/0/5 unit 0 family inet6 address 2001:db8::1/32 vrrp-inet6-group 2 accept-data
set interfaces xe-5/0/6 unit 0 family inet address 192.0.2.1/24 vrrp-group 1 virtual-address 192.0.2.5
set interfaces xe-5/0/6 unit 0 family inet address 192.0.2.1/24 vrrp-group 1 priority 50
set interfaces xe-5/0/6 unit 0 family inet address 192.0.2.1/24 vrrp-group 1 accept-data
set interfaces xe-5/0/6 unit 0 family inet6 address 2001:db8::5/32 vrrp-inet6-group 3 virtual-inet6-address
2001:db8::4
set interfaces xe-5/0/6 unit 0 family inet6 address 2001:db8::5/32 vrrp-inet6-group 3 priority 50
set interfaces xe-5/0/6 unit 0 family inet6 address 2001:db8::5/32 vrrp-inet6-group 3 accept-data

Step-by-Step Procedure

To configure VRRP groups on standalone device:

1. Set vrrp version to 3.

[edit protocols vrrp]


user@host# set version-3

2. Configure the family inet address and virtual address for the Gigabit Ethernet interface unit 0.

[edit interfaces]
user@host# set xe-5/0/5 unit 0 family inet address 192.0.2.1/24 vrrp-group 0 virtual-address 192.0.2.3
user@host# set xe-5/0/5 unit 0 family inet6 address 2001:db8::1/32 vrrp-inet6-group 2 virtual-inet6-
address 2001:db8::3
user@host# set xe-5/0/6 unit 0 family inet address 192.0.2.1/24 vrrp-group 1 virtual-address 192.0.2.5
343

user@host# set xe-5/0/6 unit 0 family inet6 address 2001:db8::5/32 vrrp-inet6-group 3 virtual-inet6-
address 2001:db8::4

3. Set the priority of the Gigabit Ethernet interface unit 0 to 50.

[edit interfaces]
user@host# set xe-5/0/5 unit 0 family inet address 192.0.2.1/24 vrrp-group 0 priority 50
user@host# set xe-5/0/5 unit 0 family inet6 address 2001:db8::1/32 vrrp-inet6-group 2 priority 50
user@host# set xe-5/0/6 unit 0 family inet address 192.0.2.1/24 vrrp-group 1 priority 50
user@host# set xe-5/0/6 unit 0 family inet6 address 2001:db8::5/32 vrrp-inet6-group 3 priority 50

4. Configure the Gigabit Ethernet interface unit 0 to accept all packets sent to the virtual IP address.

[edit interfaces]
user@host# set xe-5/0/5 unit 0 family inet address 192.0.2.1/24 vrrp-group 0 accept-data
user@host# set xe-5/0/5 unit 0 family inet6 address 2001:db8::1/32 vrrp-inet6-group 2 accept-data
user@host# set xe-5/0/6 unit 0 family inet address 192.0.2.1/24 vrrp-group 1 accept-data
user@host# set xe-5/0/6 unit 0 family inet6 address 2001:db8::5/32 vrrp-inet6-group 3 accept-data

Results

From configuration mode, confirm your configuration by entering the show interfaces xe-5/0/5 and show
interfaces xe-5/0/6 commands. If the output does not display the intended configuration, repeat the
configuration instructions in this example to correct it.

[edit]
user@host# show interfaces xe-5/0/5
unit 0 {
family inet {
address 192.0.2.1/24 {
vrrp-group 0 {
virtual-address 192.0.2.3;
priority 50;
accept-data;
}
}
}
family inet6 {
address 2001:db8::1/32 {
344

vrrp-inet6-group 2 {
virtual-inet6-address 2001:db8::3;
priority 50;
accept-data;
}
}
}
}

[edit]
user@host# show interfaces xe-5/0/6
unit 0 {
family inet {
address 192.0.2.1/24 {
vrrp-group 1 {
virtual-address 192.0.2.5;
priority 50;
accept-data;
}
}
}
family inet6 {
address 2001:db8::5/32 {
vrrp-inet6-group 3 {
virtual-inet6-address 2001:db8::4;
priority 50;
accept-data;
}
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying the VRRP on Chassis Cluster Devices | 345


345

Verifying the VRRP on standalone device | 346

Confirm that the configuration is working properly.

Verifying the VRRP on Chassis Cluster Devices

Purpose

Verify that VRRP on chassis cluster devices has been configured properly.

Action

From operational mode, enter the show vrrp brief command to display the status of VRRP on chassis
cluster devices.

user@host> show vrrp brief


Interface State Group VR state VR Mode Timer Type Address
reth0.0 up 0 master Active A 0.149 lcl 192.0.2.3
vip 192.0.2.3
reth0.0 up 2 master Active A 0.155 lcl 2001:db8::2
vip 2001:db8:5eff:fe00:202
vip 2001:db8::2
reth1.0 up 1 master Active A 0.445 lcl 192.0.2.4
vip 192.0.2.4
reth1.0 up 3 master Active A 0.414 lcl 2001:db8::4
vip 2001:db8:5eff:fe00:203
vip 2001:db8::4

Meaning

The sample output shows that the four VRRP groups are active and that the redundant interfaces has
assumed the correct primary roles. The lcl address is the physical address of the interface and the vip
address is the virtual address shared by redundant interfaces. The Timer value (A 0.149, A 0.155, A
0.445, and A 0.414) indicates the remaining time (in seconds) in which the redundant interfaces expects
to receive a VRRP advertisement from the Gigabit Ethernet interfaces. If an advertisement for group 0,
1, 2, and 3 does not arrive before the timer expires, Chassis cluster devices asserts itself as the primary.
346

Verifying the VRRP on standalone device

Purpose

Verify that VRRP has been configured properly on a standalone device.

Action

From operational mode, enter the show vrrp brief command to display the status of VRRP on standalone
device.

user@host> show vrrp brief


Interface State Group VR state VR Mode Timer Type Address
xe-5/0/5.0 up 0 backup Active D 3.093 lcl 192.0.2.2.1
vip 192.0.2.2
mas 192.0.2.2.2
xe-5/0/5.0 up 2 backup Active D 3.502 lcl 2001:db8::2:1
vip 2001:db8:200:5eff:fe00:202
vip 2001:db8::2
mas 2001:db8:210:dbff:feff:1000
xe-5/0/6.0 up 1 backup Active D 3.499 lcl 192.0.2.5.1
vip 192.0.2.5
mas 192.0.2.5.2
xe-5/0/6.0 up 3 backup Active D 3.282 lcl 2001:db8::5
vip 2001:db8:200:5eff:fe00:203
vip 2001:db8::4
mas 2001:db8:210:dbff:feff:1001

Meaning

The sample output shows that the four VRRP groups are active and that the Gigabit Ethernet interfaces
has assumed the correct backup roles. The lcl address is the physical address of the interface and the vip
address is the virtual address shared by Gigabit Ethernet interfaces. The Timer value (D 3.093, D 3.502,
D 3.499, and D 3.282) indicates the remaining time (in seconds) in which the Gigabit Ethernet interfaces
expects to receive a VRRP advertisement from the redundant interfaces. If an advertisement for group
0, 1, 2, and 3 does not arrive before the timer expires, then the standalone device continues to be a
backup device.
347

SEE ALSO

authentication-type | 600
authentication-key | 598
show vrrp | 984

Example: Configuring VRRP for IPv6

IN THIS SECTION

Requirements | 347

Overview | 347

Configuring VRRP | 348

Verification | 355

This example shows how to configure VRRP properties for IPv6.

Requirements
This example uses the following hardware and software components:

• Three routers

• Junos OS Release 11.3 or later

• This example has been recently updated and revalidated on Junos OS Release 21.1R1.

• For details on VRRP support for specific platform and Junos OS release combinations, see Feature
Explorer.

Overview
This example uses a VRRP group, which has a virtual address for IPv6. Devices on the LAN use this
virtual address as their default gateway. If the primary router fails, the backup router takes over for it.
348

Configuring VRRP

IN THIS SECTION

Configuring Router A | 349

Configuring Router B | 352

Configuring Router C | 355


349

Configuring Router A

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste into a text file, remove any line
breaks, change any details necessary to match your network configuration, and then copy and paste the
commands into the CLI at the [edit] hierarchy level.

set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64 vrrp-inet6-group 1


virtual-inet6-address 2001:db8:1:1::254
set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64 vrrp-inet6-group 1
priority 110
set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64 vrrp-inet6-group 1 accept-
data
set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64 vrrp-inet6-group 1 track
interface ge-0/0/2 priority-cost 20
set interfaces ge-0/0/2 unit 0 family inet6 address 2001:db8:1:3::1/64
set protocols router-advertisement interface ge-0/0/1.0 virtual-router-only
set protocols router-advertisement interface ge-0/0/1.0 prefix 2001:db8:1:1::/64
set routing-options rib inet6.0 static route 0::0/0 next-hop 2001:db8:1:3::2

Step-by-Step Procedure

To configure this example:

1. Configure the interfaces.

[edit]
user@routerA# set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64
user@routerA# set interfaces ge-0/0/2 unit 0 family inet6 address 2001:db8:1:3::1/64

2. Configure the IPv6 VRRP group identifier and the virtual IP address.

[edit interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64]


user@routerA# set vrrp-inet6-group 1 virtual-inet6-address 2001:db8:1:1::254
350

3. Configure the priority for RouterA higher than RouterB to become the primary virtual router. RouterB
is using the default priority of 100.

[edit interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64]


user@routerA# set vrrp-inet6-group 1 priority 110

4. Configure track interface to track whether the interface connected to the Internet is up, down, or not
present to change the priority of the VRRP group.

[edit interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64]


user@routerA# set vrrp-inet6-group 1 track interface ge-0/0/2 priority-cost 20

5. Configure accept-data to enable the primary router to accept all packets destined for the virtual IP
address.

[edit interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::1/64]


user@routerA# set vrrp-inet6-group 1 accept-data

6. Configure a static route for traffic to the Internet.

[edit]
user@routerA# set routing-options rib inet6.0 static route 0::0/0 next-hop 2001:db8:1:3::2

7. For VRRP for iPv6, you must configure the interface on which VRRP is configured to send IPv6 router
advertisements for the VRRP group. When an interface receives an IPv6 router solicitation message,
it sends an IPv6 router advertisement to all VRRP groups configured on it.

[edit protocols router-advertisement interface ge-0/0/1.0]


user@routerA# set prefix 2001:db8:1:1::/64

8. Configure router advertisements to be sent only for VRRP IPv6 groups configured on the interface if
the groups are in the primary state.

[edit protocols router-advertisement interface ge-0/0/1.0]


user@routerA# set virtual-router-only
351

Results

From configuration mode, confirm your configuration by entering the show interfaces, show protocols router-
advertisement and show routing-options commands. If the output does not display the intended
configuration, repeat the instructions in this example to correct the configuration.

[edit]
user@routerA# show interfaces
ge-0/0/1 {
unit 0 {
family inet6 {
address 2001:db8:1:1::1/64 {
vrrp-inet6-group 1 {
virtual-inet6-address 2001:db8:1:1::254;
priority 110;
accept-data;
track {
interface ge-0/0/2 {
priority-cost 20;
}
}
}
}
}
}
}
ge-0/0/2 {
unit 0 {
family inet6 {
address 2001:db8:1:3::1/64;
}
}
}

[edit]
user@routerA# show protocols router-advertisement
interface ge-0/0/1.0 {
virtual-router-only;
352

prefix 2001:db8:1:1::/64;
}

[edit]
user@routerA# show routing-options
rib inet6.0 {
static {
route 0::0/0 next-hop 2001:db8:1:3::2;
}
}

If you are done configuring the device, enter commit from configuration mode.

Configuring Router B

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, and then copy and paste
the commands into the CLI at the [edit] hierarchy level.

set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::2/64 vrrp-inet6-group 1


virtual-inet6-address 2001:db8:1:1::254
set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::2/64 vrrp-inet6-group 1
priority 110
set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::2/64 vrrp-inet6-group 1 accept-
data
set protocols router-advertisement interface ge-0/0/1.0 virtual-router-only
set protocols router-advertisement interface ge-0/0/1.0 prefix 2001:db8:1:1::/64

Step-by-Step Procedure

To configure this example:


353

1. Configure the interfaces.

[edit]
user@routerB# set interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::2/64
user@routerB# set interfaces ge-0/0/2 unit 0 family inet6 address 2001:db8:1:4::1/64

2. Configure the IPv6 VRRP group identifier and the virtual IP address.

[edit interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::2/64]


user@routerB# set vrrp-inet6-group 1 virtual-inet6-address 2001:db8:1:1::254

3. Configure accept-data to enable the backup router to accept all packets destined for the virtual IP
address in the event the backup router becomes primary.

[edit interfaces ge-0/0/1 unit 0 family inet6 address 2001:db8:1:1::2/64]


user@routerB# set vrrp-inet6-group 1 accept-data

4. Configure a static route for traffic to the Internet.

[edit]
user@routerB# set routing-options rib inet6.0 static route 0::0/0 next-hop 2001:db8:1:4::2

5. Configure the interface on which VRRP is configured to send IPv6 router advertisements for the
VRRP group. When an interface receives an IPv6 router solicitation message, it sends an IPv6 router
advertisement to all VRRP groups configured on it.

[edit protocols router-advertisement interface ge-0/0/1.0]


user@routerB# set prefix 2001:db8:1:1::/64

6. Configure router advertisements to be sent only for VRRP IPv6 groups configured on the interface if
the groups are in the primary state.

[edit protocols router-advertisement interface ge-0/0/1.0]


user@routerB# set virtual-router-only
354

Results

From configuration mode, confirm your configuration by entering the show interfaces, show protocols router-
advertisement and show routing-options commands. If the output does not display the intended
configuration, repeat the instructions in this example to correct the configuration.

[edit]
user@routerB# show interfaces
ge-0/0/1 {
unit 0 {
family inet6 {
address 2001:db8:1:1::2/64 {
vrrp-inet6-group 1 {
virtual-inet6-address 2001:db8:1:1::254;
accept-data;
}
}
}
}
}
ge-0/0/2 {
unit 0 {
family inet6 {
address 2001:db8:1:4::1/64;
}
}
}

[edit]
user@routerB# show protocols router-advertisement
interface ge-0/0/1.0 {
virtual-router-only;
prefix 2001:db8:1:1::/64;
}

[edit]
user@routerB# show routing-options
rib inet6.0 {
static {
355

route 0::0/0 next-hop 2001:db8:1:4::2;


}
}

If you are done configuring the device, enter commit from configuration mode.

Configuring Router C

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, and then copy and paste
the commands into the CLI at the [edit] hierarchy level.

set interfaces ge-0/0/0 unit 0 family inet6 address 2001:db8:1:1::3/64


set routing-options rib inet6.0 static route 0::0/0 next-hop 2001:db8:1:1::254

Verification

IN THIS SECTION

Verifying That VRRP Is Working on Router A | 355

Verifying That VRRP Is Working on Router B | 356

Verifying Router C Reaches the Internet Transiting Router A | 357

Verifying Router B Becomes Primary for VRRP | 358

Verifying That VRRP Is Working on Router A

Purpose

Verify that VRRP is active on Router A and that its role in the VRRP group is correct.
356

Action

Use the following commands to verify that VRRP is active on Router A, that the router is primary for
group 1 and the interface connected to the Internet is being tracked.

user@routerA> show vrrp


Interface State Group VR state VR Mode Timer Type Address
ge-0/0/1.0 up 1 master Active A 0.690 lcl 2001:db8:1:1::1
vip fe80::200:5eff:fe00:201
vip 2001:db8:1:1::254

user@routerA> show vrrp track


Track Int State Speed VRRP Int Group VR State Current prio
ge-0/0/2.0 up 1g ge-0/0/1.0 1 master 110

Meaning

The show vrrp command displays fundamental information about the VRRP configuration. This output
shows that the VRRP group is active and that this router has assumed the primary role. The lcl address
is the physical address of the interface and the vip address is the virtual address shared by both routers.
The Timer value (A 0.690) indicates the remaining time (in seconds) in which this router expects to receive
a VRRP advertisement from the other router.

Verifying That VRRP Is Working on Router B

Purpose

Verify that VRRP is active on Router B and that its role in the VRRP group is correct.

Action

Use the following command to verify that VRRP is active on Router B and that the router is backup for
group 1.

user@routerB> show vrrp


Interface State Group VR state VR Mode Timer Type Address
ge-0/0/1.0 up 1 backup Active D 2.947 lcl 2001:db8:1:1::2
vip fe80::200:5eff:fe00:201
357

vip 2001:db8:1:1::254
mas fe80::5668:a0ff:fe99:2d7d

Meaning

The show vrrp command displays fundamental information about the VRRP configuration. This output
shows that the VRRP group is active and that this router has assumed the backup role. The lcl address is
the physical address of the interface and the vip address is the virtual address shared by both routers.
The Timer value (D 2.947) indicates the remaining time (in seconds) in which this router expects to receive
a VRRP advertisement from the other router.

Verifying Router C Reaches the Internet Transiting Router A

Purpose

Verify connectivity to the Internet from Router C.

Action

Use the following commands to verify that Router C can reach the Internet.

user@routerC> ping 2001:db8:16:255::1 count 2


PING6(56=40+8+8 bytes) 2001:db8:1:1::3 --> 2001:db8:16:255::1
16 bytes from 2001:db8:16:255::1, icmp_seq=0 hlim=63 time=12.810 ms
16 bytes from 2001:db8:16:255::1, icmp_seq=1 hlim=63 time=30.139 ms

--- 2001:db8:16:255::1 ping6 statistics ---


2 packets transmitted, 2 packets received, 0% packet loss
round-trip min/avg/max/std-dev = 12.810/21.474/30.139/8.664 ms

user@routerC> traceroute 2001:db8:16:255::1


traceroute6 to 2001:db8:16:255::1 (2001:db8:16:255::1) from 2001:db8:1:1::3, 64 hops max, 12
byte packets
1 2001:db8:1:1::1 (2001:db8:1:1::1) 9.891 ms 32.353 ms 7.859 ms
2 2001:db8:16:255::1 (2001:db8:16:255::1) 257.483 ms 19.877 ms 7.451 ms
358

Meaning

The ping command shows reachabilty to the Internet and the traceroute command shows that Router A is
being transited.

Verifying Router B Becomes Primary for VRRP

Purpose

Verify that Router B becomes primary for VRRP when the interface between Router A and the Internet
goes down.

Action

Use the following commands to verify that Router B is primary and that Router C can reach the Internet
transiting Router B.

user@routerA> show vrrp track detail


Tracked interface: ge-0/0/2.0
State: down, Speed: 1g
Incurred priority cost: 20
Tracking VRRP interface: ge-0/0/1.0, Group: 1
VR State: backup
Current priority: 90, Configured priority: 110
Priority hold-time: disabled

user@routerB> show vrrp


Interface State Group VR state VR Mode Timer Type Address
ge-0/0/1.0 up 1 master Active A 0.119 lcl 2001:db8:1:1::2
vip fe80::200:5eff:fe00:201
vip 2001:db8:1:1::254

user@routerC> traceroute 2001:db8:16:255::1


traceroute6 to 2001:db8:16:255::1 (2001:db8:16:255::1) from 2001:db8:1:1::3, 64 hops max, 12
byte packets
1 2001:db8:1:1::2 (2001:db8:1:1::2) 52.945 ms 344.383 ms 29.540 ms
2 2001:db8:16:255::1 (2001:db8:16:255::1) 46.168 ms 24.744 ms 23.867 ms
359

Meaning

The show vrrp track detail command shows the tracked interface is down on Router A, that the priority
has dropped to 90, and that Router A is now the backup. The show vrrp command shows that Router B is
now the primary for VRRP and the traceroute command shows that Router B is now being transited.

SEE ALSO

Understanding VRRP
Configuring VRRP
Configuring VRRP Route Tracking

RELATED DOCUMENTATION

Chassis Cluster Redundant Ethernet Interfaces | 99


Configuring Chassis Clustering on SRX Series Devices | 129

NTP Time Synchronization on Chassis Cluster

IN THIS SECTION

NTP Time Synchronization on SRX Series Devices | 360

Example: Simplifying Network Management by Synchronizing the Primary and Backup Nodes with
NTP | 360

Network Time Protocol (NTP) is used to synchronize the time between the Packet Forwarding Engine
and the Routing Engine in a standalone device and between two devices in a chassis cluster. For more
information, see the following topics:
360

NTP Time Synchronization on SRX Series Devices

In both standalone and chassis cluster modes, the primary Routing Engine runs the NTP process to get
the time from the external NTP server. Although the secondary Routing Engine runs the NTP process in
an attempt to get the time from the external NTP server, this attempt fails because of network issues.
For this reason, the secondary Routing Engine uses NTP to get the time from the primary Routing
Engine.

Use NTP to:

• Send the time from the primary Routing Engine to the secondary Routing Engine through the chassis
cluster control link.

• Get the time from an external NTP server to the primary or a standalone Routing Engine.

• Get the time from the Routing Engine NTP process to the Packet Forwarding Engine.

Starting with Junos OS Release 15.1X49-D70 and Junos OS Release 17.3R1, configuring the NTP time
adjustment threshold is supported on SRX300, SRX320, SRX340, SRX345, SRX1500, SRX4100,
SRX4200, SRX5400, SRX5600, and SRX5800 devices and vSRX Virtual Firewall instances. This feature
allows you to configure and enforce the NTP adjustment threshold for the NTP service and helps in
improve the security and flexibility of the NTP service protocol.

SEE ALSO

NTP Overview
ntp threshold | 675
show system ntp threshold | 959
set date ntp | 957

Example: Simplifying Network Management by Synchronizing the


Primary and Backup Nodes with NTP

IN THIS SECTION

Requirements | 361

Overview | 361
361

Configuration | 362

Verification | 364

This example shows how to simplify management by synchronizing the time between two SRX Series
Firewalls operating in a chassis cluster. Using a Network Time Protocol (NTP) server, the primary node
can synchronize time with the secondary node. NTP is used to synchronize the time between the Packet
Forwarding Engine and the Routing Engine in a standalone device and between two devices in a chassis
cluster. You need to synchronize the system clocks on both nodes of the SRX Series Firewalls in a
chassis cluster in order to manage the following items:

• Real-time objects (RTO)

• Licenses

• Software updates

• Node failovers

• Analyzing system logs (syslogs)

Requirements
This example uses the following hardware and software components:

• SRX Series Firewalls operating in a chassis cluster

• Junos OS Release 12.1X47-D10 or later

Before you begin:

• Understand the basics of the Network Time Protocol. See NTP Overview.

Overview

IN THIS SECTION

Topology | 362

When SRX Series Firewalls are operating in chassis cluster mode, the secondary node cannot access the
external NTP server through the revenue port. Junos OS Release 12.1X47 or later supports
362

synchronization of secondary node time with the primary node through the control link by configuring
the NTP server on the primary node.

Topology

Figure 40 on page 362 shows the time synchronization from the peer node using the control link.

Figure 40: Synchronizing Time From Peer Node Through Control Link

In the primary node, the NTP server is reachable. The NTP process on the primary node can synchronize
the time from the NTP server, and the secondary node can synchronize the time with the primary node
from the control link.

Configuration

IN THIS SECTION

CLI Quick Configuration | 362

Synchronizing Time from the NTP server | 363

Results | 363

CLI Quick Configuration

To quickly configure this example, and synchronize the time from the NTP server, copy the following
commands, paste them into a text file, remove any line breaks, change any details necessary to match
363

your network configuration, copy and paste the commands into the CLI at the [edit] hierarchy level, and
then enter commit from configuration mode.

set system ntp server 1.1.1.121

Synchronizing Time from the NTP server

Step-by-Step Procedure

In this example, you configure the primary node to get its time from an NTP server at IP address
1.1.1.121. To synchronize the time from the NTP server:

1. Configure the NTP server.

{primary:node0}[edit]
[edit system]
user@host# set ntp server 1.1.1.121

2. Commit the configuration.

user@host#commit

Results

From configuration mode, confirm your configuration by entering the show system ntp command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

{primary:node0}[edit]
user@host# show system ntp
server 1.1.1.121

If you are done configuring the device, enter commit from configuration mode.
364

Verification

IN THIS SECTION

Verifying the NTP Configuration on the Primary Node | 364

Verifying the NTP Configuration on the Secondary Node | 366

Confirm that the configuration is working properly.

Verifying the NTP Configuration on the Primary Node

Purpose

Verify that the configuration is working properly.

Action

From operational mode, enter the show ntp associations command:

user@host> show ntp associations


remote refid st t when poll reach delay offset jitter
==============================================================================
*1-1-1-121-dynami 10.208.0.50 4 - 63 64 65 4.909 -12.067 2.014

From operational mode, enter the show ntp status command:

user@host> show ntp status


status=0664 leap_none, sync_ntp, 6 events, event_peer/strat_chg,
version="ntpd 4.2.0-a Fri Mar 21 00:50:30 PDT 2014 (1)",
processor="i386", system="JUNOS12.1I20140320_srx_12q1_x47.1-637245",
leap=00, stratum=5, precision=-20, rootdelay=209.819,
rootdispersion=513.087, peer=14596, refid=1.1.1.121,
reftime=d6dbb2f9.b3f41ff7 Tue, Mar 25 2014 15:47:05.702, poll=6,
clock=d6dbb47a.72918b20 Tue, Mar 25 2014 15:53:30.447, state=4,
offset=-6.066, frequency=-55.135, jitter=4.343, stability=0.042
365

Meaning

The output on the primary and secondary node shows the NTP association as follows:

• remote—Address or name of the remote NTP peer.

• refid—Reference identifier of the remote peer. If the reference identifier is not known, this field
shows a value of 0.0.0.0.

• st—Stratum of the remote peer.

• t—Type of peer: b (broadcast), l (local), m (multicast), or u (unicast).

• when—When the last packet from the peer was received.

• poll—Polling interval, in seconds.

• reach—Reachability register, in octal.

• delay—Current estimated delay of the peer, in milliseconds.

• offset—Current estimated offset of the peer, in milliseconds.

• jitter—Magnitude of jitter, in milliseconds.

The output on the primary and secondary node shows the NTP status as follows:

• status—System status word, a code representing the status items listed.

• x events—Number of events that have occurred since the last code change. An event is often the
receipt of an NTP polling message.

• version—A detailed description of the version of NTP being used.

• processor—Current hardware platform and version of the processor.

• system—Detailed description of the name and version of the operating system in use.

• leap—Number of leap seconds in use.

• stratum—Stratum of the peer server. Anything greater than 1 is a secondary reference source, and the
number roughly represents the number of hops away from the stratum 1 server. Stratum 1 is a
primary reference, such as an atomic clock.

• precision—Precision of the peer clock, how precisely the frequency and time can be maintained with
this particular timekeeping system.

• rootdelay—Total roundtrip delay to the primary reference source, in seconds.


366

• rootdispersion—Maximum error relative to the primary reference source, in seconds.

• peer—Identification number of the peer in use.

• refid—Reference identifier of the remote peer. If the reference identifier is not known, this field
shows a value of 0.0.0.0.

• reftime—Local time, in timestamp format, when the local clock was last updated. If the local clock has
never been synchronized, the value is zero.

• poll—NTP broadcast message polling interval, in seconds.

• clock—Current time on the local router clock.

• state—Current mode of NTP operation, where 1 is symmetric active, 2 is symmetric passive, 3 is


client, 4 is server, and 5 is broadcast.

• offset—Current estimated offset of the peer, in milliseconds. Indicates the time difference between
the reference clock and the local clock.

• frequency—Frequency of the clock.

• jitter—Magnitude of jitter, in milliseconds.

• stability—Measurement of how well this clock can maintain a constant frequency.

Verifying the NTP Configuration on the Secondary Node

Purpose

Verify that the configuration is working properly.

Action

From operational mode, enter the show ntp associations command:

user@host> show ntp associations


remote refid st t when poll reach delay offset jitter
==============================================================================
1-1-1-121-dynami .INIT. 16 - - 1024 0 0.000 0.000 4000.00

*129.96.0.1 1.1.1.121 5 u 32 64 377 0.417 0.760 1.204


367

From operational mode, enter the show ntp status command:

user@host> show ntp status


status=0664 leap_none, sync_ntp, 6 events, event_peer/strat_chg,
version="ntpd 4.2.0-a Thu Mar 13 01:53:03 PDT 2014 (1)",
processor="i386", system="JUNOS12.1I20140312_srx_12q1_x47.2-635305",
leap=00, stratum=12, precision=-20, rootdelay=2.408,
rootdispersion=892.758, peer=51948, refid=1.1.1.121,
reftime=d6d646bb.853d2f42 Fri, Mar 21 2014 13:03:55.520, poll=6,
clock=d6d647bc.e8f28b2f Fri, Mar 21 2014 13:08:12.909, state=4,
offset=-1.126, frequency=-62.564, jitter=0.617, stability=0.002

Release History Table


Release Description

15.1X49-D70 Starting with Junos OS Release 15.1X49-D70 and Junos OS Release 17.3R1, configuring the NTP
time adjustment threshold is supported on SRX300, SRX320, SRX340, SRX345, SRX1500,
SRX4100, SRX4200, SRX5400, SRX5600, and SRX5800 devices and vSRX Virtual Firewall
instances. This feature allows you to configure and enforce the NTP adjustment threshold for the
NTP service and helps in improve the security and flexibility of the NTP service protocol.

RELATED DOCUMENTATION

Time Management Routing Guide for Administration Devices


Verifying Chassis Cluster Configuration Synchronization Status | 152

Active/Passive Chassis Cluster Deployments

IN THIS SECTION

Understanding Active/Passive Chassis Cluster Deployment | 368

Example: Configuring an Active/Passive Chassis Cluster on SRX5800 Firewalls | 369

Example: Configuring an Active/Passive Chassis Cluster Pair (SRX1500) | 387

Example: Configuring an Active/Passive Chassis Cluster Pair (J-Web) | 404


368

Understanding Active/Passive Chassis Cluster Deployment with an IPsec Tunnel | 406

Example: Configuring an Active/Passive Chassis Cluster Pair with an IPsec Tunnel | 408

Example: Configuring an Active/Passive Chassis Cluster Pair with an IPsec Tunnel (J-Web) | 430

Understanding Active/Passive Chassis Cluster Deployment

In this case, a single device in the cluster is used to route all traffic while the other device is used only in
the event of a failure (see Figure 41 on page 368). When a failure occurs, the backup device becomes
primary and controls all forwarding.

Figure 41: Active/Passive Chassis Cluster Scenario

An active/passive chassis cluster can be achieved by using redundant Ethernet interfaces (reths) that are
all assigned to the same redundancy group. If any of the interfaces in an active group in a node fails, the
group is declared inactive and all the interfaces in the group fail over to the other node.

This configuration minimizes the traffic over the fabric link because only one node in the cluster
forwards traffic at any given time.
369

SEE ALSO

Chassis Cluster Overview | 2

Example: Configuring an Active/Passive Chassis Cluster on SRX5800


Firewalls

IN THIS SECTION

Requirements | 369

Overview | 369

Configuration | 372

Verification | 379

This example shows how to set up basic active/passive chassis clustering on an SRX5800 firewalls.

Requirements
Before you begin:

• You need two SRX5800 Firewalls with identical hardware configurations, and optionally one MX240
edge router, and one EX8208 Ethernet Switch for sending end to end data traffic.

• Physically connect the two devices (back-to-back for the fabric and control ports) and ensure that
they are the same models.

• Before the cluster is formed, you must configure control ports for each device, as well as assign a
cluster ID and node ID to each device, and then reboot. When the system boots, both the nodes
come up as a cluster.

Control port configuration is required for SRX5400, SRX5600, and SRX5800 firewalls.

Now the devices are a pair. From this point forward, configuration of the cluster is synchronized
between the node members, and the two separate devices function as one device.

Overview
This example shows how to set up basic active/passive chassis clustering on an SRX Series Firewall. The
basic active/passive example is the most common type of chassis cluster.
370

The basic active/passive chassis cluster consists of two devices:

• One device actively provides routing, firewall, NAT, VPN, and security services, along with
maintaining control of the chassis cluster.

• The other device passively maintains its state for cluster failover capabilities in case the active device
becomes inactive.

This active/passive mode example for the SRX5800 Firewall does not describe in detail miscellaneous
configurations such as how to configure NAT, security policies, or VPNs. They are essentially the same
as they would be for standalone configurations. However, if you are performing proxy ARP in chassis
cluster configurations, you must apply the proxy ARP configurations to the reth interfaces rather than
the member interfaces because the RETH interfaces hold the logical configurations. See Configuring
Proxy ARP for NAT (CLI Procedure). You can also configure separate logical interface configurations
using VLANs and trunked interfaces in the SRX5800 Firewall. These configurations are similar to the
standalone implementations using VLANs and trunked interfaces.

Figure 42 on page 371 shows the topology used in this example.


371

Figure 42: Basic Active/Passive Chassis Clustering on an SRX Series Firewall Topology Example
372

Configuration

IN THIS SECTION

Configuring the Control Ports and Enabling Cluster Mode | 372

Configuring the Control Ports and Enabling Cluster Mode

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

On {primary:node0}

[edit]
set groups re0 system host-name hostA
set groups re0 system backup-router 10.204.191.254
set groups re0 system backup-router destination 10.0.0.0/8
set groups re0 system backup-router destination 172.16.0.0/16
set groups re0 system backup-router destination 192.168.0.0/16
set groups re0 interfaces fxp0 unit 0 family inet address 10.204.149.140/18
set apply-groups re0
set groups re0 system host-name hostB
set groups re0 system backup-router 10.204.191.254
set groups re0 system backup-router destination 10.0.0.0/8
set groups re0 system backup-router destination 172.16.0.0/16
set groups re0 system backup-router destination 192.168.0.0/16
set groups re0 interfaces fxp0 unit 0 family inet address 10.204.149.142/18
set apply-groups re0
set groups node0 system host-name hostA
set groups node0 system backup-router 10.204.191.254
set groups node0 system backup-router destination 10.0.0.0/8
set groups node0 system backup-router destination 172.16.0.0/16
set groups node0 system backup-router destination 192.168.0.0/16
set groups node0 interfaces fxp0 unit 0 family inet address 10.204.149.140/18
set groups node1 system host-name hostB
set groups node1 system backup-router 10.204.191.254
373

set groups node1 system backup-router destination 10.0.0.0/8


set groups node1 system backup-router destination 172.16.0.0/16
set groups node1 system backup-router destination 192.168.0.0/16
set groups node1 interfaces fxp0 unit 0 family inet address 10.204.149.142/18
set chassis cluster control-ports fpc 1 port 0
set chassis cluster control-ports fpc 13 port 0
set chassis cluster cluster-id 1 node 0 reboot
set chassis cluster cluster-id 1 node 1 reboot
delete apply-groups re0
set apply-groups “${node}”
set chassis cluster reth-count 2
set chassis cluster redundancy-group 0 node 0 priority 254
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 254
set chassis cluster redundancy-group 1 node 1 priority 1
set interfaces fab0 fabric-options member-interfaces ge-3/2/8
set interfaces fab1 fabric-options member-interfaces ge-15/2/8

(Optional) To quickly configure an EX8208 Core Switch, copy the following commands, paste them into a
text file, remove any line breaks, change any details necessary to match your network configuration,
copy and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from
configuration mode.

On {primary:node0}

[edit]
set interfaces xe-1/0/0 unit 0 family ethernet-switching port-mode access vlan members SRX5800
set interfaces xe-2/0/0 unit 0 family ethernet-switching port-mode access vlan members SRX5800
set interfaces vlan unit 50 family inet address 10.2.2.254/24
set vlans SRX5800 vlan-id 50
set vlans SRX5800 l3-interface vlan.50
set routing-options static route 0.0.0.0/0 next-hop 10.2.2.1/24

(Optional)To quickly configure an MX240 edge router, copy the following commands, paste them into a
text file, remove any line breaks, change any details necessary to match your network configuration,
copy and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from
configuration mode.

On {primary:node0}

[edit]
set interfaces xe-1/0/0 encapsulation ethernet-bridge unit 0 family ethernet-switching
374

set interfaces xe-2/0/0 encapsulation ethernet-bridge unit 0 family ethernet-switching


set interfaces irb unit 0 family inet address 10.1.1.254/24
set routing-options static route 10.0.0.0/8 next-hop 10.1.1.1
set routing-options static route 0.0.0.0/0 next-hop (upstream router)
set vlans SRX5800 vlan-id X (could be set to “none”)
set vlans SRX5800 domain-type bridge routing-interface irb.0
set vlans SRX5800 domain-type bridge interface xe-1/0/0
set vlans SRX5800 domain-type bridge interface xe-2/0/0

Step-by-Step Procedure

The following example requires you to navigate various levels in the configuration hierarchy.

To configure a chassis cluster on an SRX Series Firewall:

In cluster mode, the configuration is synchronized over the control link between the nodes when you
execute a commit command. All commands are applied to both nodes regardless of from which device the
command is configured.

1. Configure both the standalone devices with backup router destination configuration to provide the
management access on the backup node after the device is up in cluster mode. The access to the
primary node is enabled through the routing on the primary node.

user@hostA# set groups re0 system host-name hostA


user@hostA# set groups re0 system backup-router 10.204.191.254
user@hostA# set groups re0 system backup-router destination 10.0.0.0/8
user@hostA# set groups re0 system backup-router destination 172.16.0.0/16
user@hostA# set groups re0 system backup-router destination 192.168.0.0/16
user@hostA# set groups re0 interfaces fxp0 unit 0 family inet address 10.204.149.140/18
user@hostA# set apply-groups re0

user@hostB# set groups re0 system host-name hostB


user@hostB# set groups re0 system backup-router 10.204.191.254
user@hostB# set groups re0 system backup-router destination 10.0.0.0/8
user@hostB# set groups re0 system backup-router destination 172.16.0.0/16
user@hostB# set groups re0 system backup-router destination 192.168.0.0/16
user@hostB# set groups re0 interfaces fxp0 unit 0 family inet address 10.204.149.142/18
user@hostB# set apply-groups re0

2. Because the SRX5000 Firewall chassis cluster configuration is contained within a single common
configuration, to assign some elements of the configuration to a specific member only, you must
375

use the Junos OS node-specific configuration method called groups. The set apply-groups ${node}
command uses the node variable to define how the groups are applied to the nodes; each node
recognizes its number and accepts the configuration accordingly. You must also configure out-of-
band management on the fxp0 interface of the SRX5000 Firewall using separate IP addresses for
the individual control planes of the cluster.

Configuring the backup router destination address as x.x.x.0/0 is not allowed.

user@hostA# set groups node0 system host-name hostA


user@hostA# set groups node0 system backup-router 10.204.191.254
user@hostA# set groups node0 system backup-router destination 10.0.0.0/8
user@hostA# set groups node0 system backup-router destination 172.16.0.0/16
user@hostA# set groups node0 system backup-router destination 192.168.0.0/16
user@hostA# set groups node0 interfaces fxp0 unit 0 family inet address 10.204.149.140/18

user@hostB# set groups node1 system host-name hostB


user@hostB# set groups node1 system backup-router 10.204.191.254
user@hostB# set groups node1 system backup-router destination 10.0.0.0/8
user@hostB# set groups node1 system backup-router destination 172.16.0.0/16
user@hostB# set groups node1 system backup-router destination 192.168.0.0/16
user@hostB# set groups node1 interfaces fxp0 unit 0 family inet address 10.204.149.142/18

The above groups node0 and node1 configuration is committed, but not applied. Once the device is
up in cluster, these commands are applied using set apply-groups “${node}”.

3. Configure the control port for each device, and commit the configuration.

Ensure to have the physical control link connection between the SPC cards on both the nodes as
per the configuration.

The control ports are derived based on the SPC location in the chassis and offset value is based on
the platform. In the below example the SPC is present in revenue slot 1 and because offset of
SRX5800 is 12, the control ports are 1, 13. You can view the Offset value for particular platform
using “jwhoami -c” command in shell mode.You must enter the following commands on both devices.
For example:

• On node 0:

user@hostA# set chassis cluster control-ports fpc 1 port 0


user@hostA# set chassis cluster control-ports fpc 13 port 0
user@hostA# commit
376

• On node 1:

user@hostB# set chassis cluster control-ports fpc 1 port 0


user@hostB# set chassis cluster control-ports fpc 13 port 0
user@hostB# commit

4. Set the two devices to cluster mode. A reboot is required to enter into cluster mode after the
cluster ID and node ID are set. You can cause the system to boot automatically by including the
reboot parameter in the CLI command line. You must enter the operational mode commands on both
devices. For example:

• On node 0:

user@hostA> set chassis cluster cluster-id 1 node 0 reboot

• On node 1:

user@hostB> set chassis cluster cluster-id 1 node 1 reboot

The cluster ID must be the same on both devices in a cluster, but the node ID must be different
because one device is node 0 and the other device is node 1. The range for the cluster ID is 1
through 255. Setting a cluster ID to 0 is equivalent to disabling a cluster. But it is recommended to
use set chassis cluster disable to break the nodes from cluster.

5. Use the following commands to configure the node 0, which is primary. The node 1 is unreachable
till the node configuration is committed. The node 0 will automatically sync the configuration
through the control port to node 1 and it is not required to explicitly configure node 1.

user@hostA# delete apply-groups re0


user@hostA# set apply-groups “${node}”

6. Configure redundancy groups for chassis clustering. Each node has interfaces in a redundancy
group where interfaces are active in active redundancy groups (multiple active interfaces can exist
in one redundancy group). Redundancy group 0 controls the control plane and redundancy group
1+ controls the data plane and includes the data plane ports. For this active/passive mode example,
only one chassis cluster member is active at a time so you need to define redundancy groups 0 and
1 only. Besides redundancy groups, you must also define:

• Redundant Ethernet groups—Configure how many redundant Ethernet interfaces (member links)
will be active on the device so that the system can allocate the appropriate resources for it.
377

• Priority for control plane and data plane—Define which device has priority (for chassis cluster,
high priority is preferred) for the control plane, and which device is preferred to be active for the
data plane.

• In active/passive or active/active mode, the control plane (redundancy group 0) can be active
on a chassis different from the data plane (redundancy group 1+ and groups) chassis.
However, for this example we recommend having both the control and data plane active on
the same chassis member. When traffic passes through the fabric link to go to another
member node, latency is introduced (z line mode traffic).

• On SRX Series Firewalls (SRX5000 line), the IPsec VPN is not supported in active/active
chassis cluster configuration (that is, when there are multiple RG1+ redundancy groups) in Z
mode.

user@hostA# set chassis cluster reth-count 2


user@hostA# set chassis cluster redundancy-group 1 node 0 priority 254
user@hostA# set chassis cluster redundancy-group 1 node 1 priority 1
user@hostA# set chassis cluster redundancy-group 0 node 0 priority 254
user@hostA# set chassis cluster redundancy-group 0 node 1 priority 1

7. Configure the fabric (data) ports of the cluster that are used to pass RTOs in active/passive mode.
For this example, use one of the revenue ports. Define two fabric interfaces, one on each chassis, to
connect together.

Configure the data interfaces on the platform so that in the event of a data plane failover, the other
chassis cluster member can take over the connection seamlessly. Seamless transition to a new
active node will occur with data plane failover. In case of control plane failover, all the daemons are
restarted on the new node thus enabling a graceful restart to avoid losing neighborship with peers
(ospf, bgp). This promotes a seamless transition to the new node without any packet loss.

You must define the following items:

• Define the membership information of the member interfaces to the reth interface.

• Define which redundancy group the reth interface is a member of. For this active/passive
example, it is always 1.

• Define reth interface information such as the IP address of the interface.

{primary:node0}[edit]
user@hostA# set interfaces fab0 fabric-options member-interfaces ge-3/2/8
user@hostA# set interfaces fab1 fabric-options member-interfaces ge-15/2/8
378

8. (Optional) Configure the chassis cluster behavior in case of a failure. For the SRX5800 Firewall, the
failover threshold is set at 255. You can alter the weights to determine the impact on the chassis
failover. You must also configure control link recovery. The recovery automatically causes the
secondary node to reboot should the control link fail, and then come back online. Enter these
commands on node 0.

{primary:node0}[edit]
user@hostA# set chassis cluster redundancy-group 1 interface-monitor xe-6/0/0 weight 255
user@hostA# set chassis cluster redundancy-group 1 interface-monitor xe-6/1/0 weight 255
user@hostA# set chassis cluster redundancy-group 1 interface-monitor xe-18/0/0 weight 255
user@hostA# set chassis cluster redundancy-group 1 interface-monitor xe-18/1/0 weight 255
user@hostA# set chassis cluster control-link-recovery

This step completes the chassis cluster configuration part of the active/passive mode example for
the SRX5800 Firewall. The rest of this procedure describes how to configure the zone, virtual
router, routing, EX8208 Core Switch, and MX240 Edge Router to complete the deployment
scenario.

9. (Optional) Configure and connect the reth interfaces to the appropriate zones and virtual routers.
For this example, leave the reth0 and reth1 interfaces in the default virtual router inet.0, which
does not require any additional configuration.

{primary:node0}[edit]
user@hostA# set security zones security-zone untrust interfaces reth0.0
user@hostA# set security zones security-zone trust interfaces reth1.0

10. (Optional) For this active/passive mode example, because of the simple network architecture, use
static routes to define how to route to the other network devices.

{primary:node0}[edit]
user@hostA# set routing-options static route 0.0.0.0/0 next-hop 10.1.1.254
user@hostA# set routing-options static route 10.0.0.0/8 next-hop 10.2.2.254

11. (Optional) For the EX8208 Ethernet Switch, the following commands provide only an outline of the
applicable configuration as it pertains to this active/passive mode example for the SRX5800
Firewall; most notably the VLANs, routing, and interface configuration.

{primary:node0}[edit]
user@hostA# set interfaces xe-1/0/0 unit 0 family ethernet-switching port-mode access vlan
members SRX5800
379

user@hostA# set interfaces xe-2/0/0 unit 0 family ethernet-switching port-mode access vlan
members SRX5800
user@hostA# set interfaces vlan unit 50 family inet address 10.2.2.254/24
user@hostA# set vlans SRX5800 vlan-id 50
user@hostA# set vlans SRX5800 l3-interface vlan.50
user@hostA# set routing-options static route 0.0.0.0/0 next-hop 10.2.2.1/24

12. (Optional) For the MX240 edge router, the following commands provide only an outline of the
applicable configuration as it pertains to this active/passive mode example for the SRX5800
Firewall; most notably you must use an IRB interface within a virtual switch instance on the switch.

{primary:node0}[edit]
user@hostA# set interfaces xe-1/0/0 encapsulation ethernet-bridge unit 0 family ethernet-
switching
user@hostA# set interfaces xe-2/0/0 encapsulation ethernet-bridge unit 0 family ethernet-
switching
user@hostA# set interfaces irb unit 0 family inet address 10.1.1.254/24
user@hostA# set routing-options static route 10.0.0.0/8 next-hop 10.1.1.1
user@hostA# set routing-options static route 0.0.0.0/0 next-hop (upstream router)
user@hostA# set vlans SRX5800 vlan-id X (could be set to “none”)
user@hostA# set vlans SRX5800 domain-type bridge routing-interface irb.0
user@hostA# set vlans SRX5800 domain-type bridge interface xe-1/0/0
user@hostA# set vlans SRX5800 domain-type bridge interface xe-2/0/0

Verification

IN THIS SECTION

Verifying Chassis Cluster Status | 380

Verifying Chassis Cluster Interfaces | 380

Verifying Chassis Cluster Statistics | 381

Verifying Chassis Cluster Control Plane Statistics | 383

Verifying Chassis Cluster Data Plane Statistics | 384

Verifying Chassis Cluster Redundancy Group Status | 386

Troubleshooting with Logs | 386

Confirm that the configuration is working properly.


380

Verifying Chassis Cluster Status

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring RE Relinquish monitoring

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Verifying Chassis Cluster Interfaces

Purpose

Verify information about chassis cluster interfaces.


381

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA
0 em0 Up Disabled
1 em1 Down Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status
(Physical/Monitored)
fab0 ge-3/2/8 Up / Up
fab0
fab1 ge-15/2/8 Up / Up
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Verifying Chassis Cluster Statistics

Purpose

Verify information about chassis cluster services and control link statistics (heartbeats sent and
received), fabric link statistics (probes sent and received), and the number of RTOs sent and received for
services.
382

Action

From operational mode, enter the show chassis cluster statistics command.

{primary:node0}
user@host> show chassis cluster statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 16275
Heartbeat packets received: 16072
Heartbeat packet errors: 0
Control link 1:
Heartbeat packets sent: 0
Heartbeat packets received: 0
Heartbeat packet errors: 0
Fabric link statistics:
Child link 0
Probes sent: 30690
Probes received: 9390
Child link 1
Probes sent: 0
Probes received: 0
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
DS-LITE create 0 0
Session create 0 0
IPv6 session create 0 0
Session close 0 0
IPv6 session close 0 0
Session change 0 0
IPv6 session change 0 0
ALG Support Library 0 0
Gate create 0 0
Session ageout refresh requests 0 0
IPv6 session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPv6 session ageout refresh replies 0 0
IPSec VPN 0 0
383

Firewall user authentication 0 0


MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
JSF PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0
GPRS SCTP 0 0
GPRS FRAMEWORK 0 0
JSF RTSP ALG 0 0
JSF SUNRPC MAP 0 0
JSF MSRPC MAP 0 0
DS-LITE delete 0 0
JSF SLB 0 0
APPID 0 0
JSF MGCP MAP 0 0
JSF H323 ALG 0 0
JSF RAS ALG 0 0
JSF SCCP MAP 0 0
JSF SIP MAP 0 0
PST_NAT_CREATE 0 0
PST_NAT_CLOSE 0 0
PST_NAT_UPDATE 0 0
JSF TCP STACK 0 0
JSF IKE ALG 0 0

Verifying Chassis Cluster Control Plane Statistics

Purpose

Verify information about chassis cluster control plane statistics (heartbeats sent and received) and the
fabric link statistics (probes sent and received).
384

Action

From operational mode, enter the show chassis cluster control-plane statistics command.

{primary:node0}
user@host> show chassis cluster control-plane statistics
Control link statistics:
Control link 0:
Heartbeat packets sent: 16315
Heartbeat packets received: 16113
Heartbeat packet errors: 0
Control link 1:
Heartbeat packets sent: 0
Heartbeat packets received: 0
Heartbeat packet errors: 0
Fabric link statistics:
Child link 0
Probes sent: 30772
Probes received: 9472
Child link 1
Probes sent: 0
Probes received: 0

Verifying Chassis Cluster Data Plane Statistics

Purpose

Verify information about the number of RTOs sent and received for services.

Action

From operational mode, enter the show chassis cluster data-plane statistics command.

{primary:node0}
user@host> show chassis cluster data-plane statistics
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
385

DS-LITE create 0 0
Session create 0 0
IPv6 session create 0 0
Session close 0 0
IPv6 session close 0 0
Session change 0 0
IPv6 session change 0 0
ALG Support Library 0 0
Gate create 0 0
Session ageout refresh requests 0 0
IPv6 session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPv6 session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
JSF PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0
GPRS SCTP 0 0
GPRS FRAMEWORK 0 0
JSF RTSP ALG 0 0
JSF SUNRPC MAP 0 0
JSF MSRPC MAP 0 0
DS-LITE delete 0 0
JSF SLB 0 0
APPID 0 0
JSF MGCP MAP 0 0
JSF H323 ALG 0 0
JSF RAS ALG 0 0
JSF SCCP MAP 0 0
JSF SIP MAP 0 0
PST_NAT_CREATE 0 0
PST_NAT_CLOSE 0 0
PST_NAT_UPDATE 0 0
386

JSF TCP STACK 0 0


JSF IKE ALG 0 0

Verifying Chassis Cluster Redundancy Group Status

Purpose

Verify the state and priority of both nodes in a cluster and information about whether the primary node
has been preempted or whether there has been a manual failover.

Action

From operational mode, enter the chassis cluster status redundancy-group command.

{primary:node0}
user@host> show chassis cluster status redundancy-group 1
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring RE Relinquish monitoring

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 1 , Failover count: 1


node0 254 primary no no None
node1 1 secondary no no None

Troubleshooting with Logs

Purpose

Use these logs to identify any chassis cluster issues. You must run these logs on both nodes.
387

Action

From operational mode, enter these show log commands.

user@host> show log jsrpd


user@host> show log chassisd
user@host> show log messages
user@host> show log dcd
user@host> show traceoptions

SEE ALSO

Preparing Your Equipment for Chassis Cluster Formation | 31


Connecting SRX Series Firewalls to Create a Chassis Cluster | 34

Example: Configuring an Active/Passive Chassis Cluster Pair (SRX1500)

IN THIS SECTION

Requirements | 387

Overview | 388

Configuration | 392

Verification | 398

This example shows how to configure active/passive chassis clustering for SRX1500 device.

Requirements
Before you begin:

1. Physically connect a pair of devices together, ensuring that they are the same models.

2. Create a fabric link by connecting a Gigabit Ethernet interface on one device to another Gigabit
Ethernet interface on the other device.
388

3. Create a control link by connecting the control port of the two SRX1500 devices.

4. Connect to one of the devices using the console port. (This is the node that forms the cluster.) and
set the cluster ID and node number.

user@host> set chassis cluster cluster-id 1 node 0 reboot

5. Connect to the other device using the console port and set the cluster ID and node number.

user@host> set chassis cluster cluster-id 1 node 1 reboot

Overview
In this example, a single device in the cluster is used to route all traffic, and the other device is used only
in the event of a failure. (See Figure 43 on page 388.) When a failure occurs, the backup device becomes
primary and controls all forwarding.

Figure 43: Active/Passive Chassis Cluster Topology

You can create an active/passive chassis cluster by configuring redundant Ethernet interfaces (reths) that
are all assigned to the same redundancy group. This configuration minimizes the traffic over the fabric
link because only one node in the cluster forwards traffic at any given time.
389

In this example, you configure group (applying the configuration with the apply-groups command) and
chassis cluster information. Then you configure security zones and security policies. See Table 20 on
page 389 through Table 23 on page 391.

Table 20: Group and Chassis Cluster Configuration Parameters

Feature Name Configuration Parameters

Groups node0 • Hostname: srx1500-A

• Interface: fxp0

• Unit 0

• 192.0.2.110/24

node1 • Hostname: srx1500-B

• Interface: fxp0

• Unit 0

• 192.0.2.111/24

Table 21: Chassis Cluster Configuration Parameters

Feature Name Configuration Parameters

Fabric links fab0 Interface: ge-0/0/1

fab1 Interface: ge-7/0/1

Heartbeat interval – 1000

Heartbeat threshold – 3
390

Table 21: Chassis Cluster Configuration Parameters (Continued)

Feature Name Configuration Parameters

Redundancy group 0 • Priority:

• Node 0: 254

• Node 1: 1

1 • Priority:

• Node 0: 254

• Node 1: 1

Interface monitoring

• ge-0/0/4

• ge-7/0/4

• ge-0/0/5

• ge-7/0/5

Number of redundant Ethernet interfaces – 2

Interfaces ge-0/0/4 Redundant parent: reth0

ge-7/0/4 Redundant parent: reth0

ge-0/0/5 Redundant parent: reth1

ge-7/0/5 Redundant parent: reth1

reth0 Redundancy group: 1


391

Table 21: Chassis Cluster Configuration Parameters (Continued)

Feature Name Configuration Parameters

• Unit 0

• 198.51.100.1/24

reth1 Redundancy group: 1

• Unit 0

• 203.0.113.233/24

Table 22: Security Zone Configuration Parameters

Name Configuration Parameters

trust The reth1.0 interface is bound to this zone.

untrust The reth0.0 interface is bound to this zone.

Table 23: Security Policy Configuration Parameters

Purpose Name Configuration Parameters

This security policy permits traffic from the trust zone to the untrust ANY • Match criteria:
zone.
• source-address any

• destination-address any

• application any

• Action: permit
392

Configuration

IN THIS SECTION

Procedure | 392

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

[edit]
set groups node0 system host-name srx1500-A
set groups node0 interfaces fxp0 unit 0 family inet address 192.0.2.110/24
set groups node1 system host-name srx1500-B
set groups node1 interfaces fxp0 unit 0 family inet address 192.0.2.111/24
set apply-groups “${node}”
set interfaces fab0 fabric-options member-interfaces ge-0/0/1
set interfaces fab1 fabric-options member-interfaces ge-7/0/1
set chassis cluster heartbeat-interval 1000
set chassis cluster heartbeat-threshold 3
set chassis cluster redundancy-group 0 node 0 priority 100
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 100
set chassis cluster redundancy-group 1 node 1 priority 1
set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-7/0/4 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-7/0/5 weight 255
set chassis cluster reth-count 2
set interfaces ge-0/0/5 gigether-options redundant-parent reth1
set interfaces ge-7/0/5 gigether-options redundant-parent reth1
set interfaces ge-0/0/4 gigether-options redundant-parent reth0
set interfaces ge-7/0/4 gigether-options redundant-parent reth0
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 family inet address 198.51.100.1/24
393

set interfaces reth1 redundant-ether-options redundancy-group 1


set interfaces reth1 unit 0 family inet address 203.0.113.233/24
set security zones security-zone untrust interfaces reth1.0
set security zones security-zone trust interfaces reth0.0
set security policies from-zone trust to-zone untrust policy ANY match source-address any
set security policies from-zone trust to-zone untrust policy ANY match destination-address any
set security policies from-zone trust to-zone untrust policy ANY match application any
set security policies from-zone trust to-zone untrust policy ANY then permit

Step-by-Step Procedure

To configure an active/passive chassis cluster:

1. Configure the management interface.

{primary:node0}[edit]
user@host# set groups node0 system host-name srx1500-A
user@host# set groups node0 interfaces fxp0 unit 0 family inet address 192.0.2.110/24
user@host# set groups node1 system host-name srx1500-B
user@host# set groups node1 interfaces fxp0 unit 0 family inet address 192.0.2.111/24
user@host# set apply-groups “${node}”

2. Configure the fabric interface.

{primary:node0}[edit]
user@host# set interfaces fab0 fabric-options member-interfaces ge-0/0/1
user@host# set interfaces fab1 fabric-options member-interfaces ge-7/0/1

3. Configure heartbeat settings.

{primary:node0}[edit]
user@host# set chassis cluster heartbeat-interval 1000
user@host# set chassis cluster heartbeat-threshold 3

4. Configure redundancy groups.

{primary:node0}[edit]
user@host# set chassis cluster redundancy-group 0 node 0 priority 100
user@host# set chassis cluster redundancy-group 0 node 1 priority 1
394

user@host# set chassis cluster redundancy-group 1 node 0 priority 100


user@host# set chassis cluster redundancy-group 1 node 1 priority 1
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/4 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-7/0/4 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/5 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-7/0/5 weight 255

5. Configure redundant Ethernet interfaces.

{primary:node0}[edit]
user@host# set chassis cluster reth-count 2
user@host# set interfaces ge-0/0/5 gigether-options redundant-parent reth1
user@host# set interfaces ge-7/0/5 gigether-options redundant-parent reth1
user@host# set interfaces ge-0/0/4 gigether-options redundant-parent reth0
user@host# set interfaces ge-7/0/4 gigether-options redundant-parent reth0
user@host# set interfaces reth0 redundant-ether-options redundancy-group 1
user@host# set interfaces reth0 unit 0 family inet address 198.51.100.1/24
user@host# set interfaces reth1 redundant-ether-options redundancy-group 1
user@host# set interfaces reth1 unit 0 family inet address 203.0.113.233/24

6. Configure security zones.

{primary:node0}[edit]
user@host# set security zones security-zone untrust interfaces reth1.0
user@host# set security zones security-zone trust interfaces reth0.0

7. Configure security policies.

{primary:node0}[edit]
user@host# set security policies from-zone trust to-zone untrust policy ANY match source-
address any
user@host# set security policies from-zone trust to-zone untrust policy ANY match destination-
address any
user@host# set security policies from-zone trust to-zone untrust policy ANY match application
any
user@host# set security policies from-zone trust to-zone untrust policy ANY then permit
395

Results

From configuration mode, confirm your configuration by entering the show configuration command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

user@host> show configuration


version x.xx.x;
groups {
node0 {
system {
host-name srx1500-A;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.0.2.110/24;
}
}
}
}
}
node1 {
system {
host-name srx1500-B;
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.0.2.110/24;
}
}
}
}
}
}
apply-groups "${node}";
chassis {
396

cluster {
reth-count 2;
heartbeat-interval 1000;
heartbeat-threshold 3;
redundancy-group 0 {
node 0 priority 100;
node 1 priority 1;
}
redundancy-group 1 {
node 0 priority 100;
node 1 priority 1;
interface-monitor {
ge–0/0/4 weight 255;
ge–7/0/4 weight 255;
ge–0/0/5 weight 255;
ge–7/0/5 weight 255;
}
}
}
}
interfaces {
ge–0/0/4 {
gigether–options {
redundant–parent reth0;
}
}
ge–7/0/4{
gigether–options {
redundant–parent reth0;
}
}
ge–0/0/5 {
gigether–options {
redundant–parent reth1;
}
}
ge–7/0/5 {
gigether–options {
redundant–parent reth1;
}
}
fab0 {
fabric–options {
397

member–interfaces {
ge–0/0/1;
}
}
}
fab1 {
fabric–options {
member–interfaces {
ge–7/0/1;
}
}
}
reth0 {
redundant–ether–options {
redundancy–group 1;
}
unit 0 {
family inet {
address 198.51.100.1/24;
}
}
}
reth1 {
redundant–ether–options {
redundancy–group 1;
}
unit 0 {
family inet {
address 203.0.113.233/24;
}
}
}
}
...
security {
zones {
security–zone untrust {
interfaces {
reth1.0;
}
}
security–zone trust {
interfaces {
398

reth0.0;
}
}
}
policies {
from-zone trust to-zone untrust {
policy ANY {
match {
source-address any;
destination-address any;
application any;
}
then {
permit;
}
}
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying Chassis Cluster Status | 399

Verifying Chassis Cluster Interfaces | 399

Verifying Chassis Cluster Statistics | 400

Verifying Chassis Cluster Control Plane Statistics | 401

Verifying Chassis Cluster Data Plane Statistics | 402

Verifying Chassis Cluster Redundancy Group Status | 403

Troubleshooting with Logs | 403

Confirm that the configuration is working properly.


399

Verifying Chassis Cluster Status

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 100 primary no no
node1 1 secondary no no

Redundancy group: 1 , Failover count: 1


node0 100 primary no no
node1 1 secondary no no

Verifying Chassis Cluster Interfaces

Purpose

Verify information about chassis cluster interfaces.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces

Control link status: Up

Control interfaces:
Index Interface Monitored-Status Security
400

0 em0 Up Disabled
1 em1 Down Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
fab0 ge-0/0/1 Up Disabled
fab0
fab1 ge-7/0/1 Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 1

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-0/0/4 255 Up 1
ge-7/0/4 255 Up 1
ge-0/0/5 255 Up 1
ge-7/0/5 255 Up 1

Verifying Chassis Cluster Statistics

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitored interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster statistics command.

{primary:node0}
user@host> show chassis cluster statistics
401

Control link statistics:


Control link 0:
Heartbeat packets sent: 2276
Heartbeat packets received: 2280
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 2272
Probes received: 597
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 6 0
Session create 161 0
Session close 148 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Verifying Chassis Cluster Control Plane Statistics

Purpose

Verify information about chassis cluster control plane statistics (heartbeats sent and received) and the
fabric link statistics (probes sent and received).
402

Action

From operational mode, enter the show chassis cluster control-plane statistics command.

{primary:node0}
user@host> show chassis cluster control-plane statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 258689
Heartbeat packets received: 258684
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 258681
Probes received: 258681

Verifying Chassis Cluster Data Plane Statistics

Purpose

Verify information about the number of RTOs sent and received for services.

Action

From operational mode, enter the show chassis cluster data-plane statistics command.

{primary:node0}
user@host> show chassis cluster data-plane statistics

Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 6 0
Session create 161 0
Session close 148 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
403

Session ageout refresh replies 0 0


IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Verifying Chassis Cluster Redundancy Group Status

Purpose

Verify the state and priority of both nodes in a cluster and information about whether the primary node
has been preempted or whether there has been a manual failover.

Action

From operational mode, enter the chassis cluster status redundancy-group command.

{primary:node0}
user@host> show chassis cluster status redundancy-group 1
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy-Group: 1, Failover count: 1


node0 100 primary no no
node1 1 secondary no no

Troubleshooting with Logs

Purpose

Use these logs to identify any chassis cluster issues. You must run these logs on both nodes.
404

Action

From operational mode, enter these show commands.

user@host> show log jsrpd


user@host> show log chassisd
user@host> show log messages
user@host> show log dcd
user@host> show traceoptions

SEE ALSO

Example: Setting the Node ID and Cluster ID for Security Devices in a Chassis Cluster | 40
Chassis Cluster Management Interfaces | 44
Chassis Cluster Fabric Interfaces | 54
Chassis Cluster Control Plane Interfaces | 67
Chassis Cluster Redundancy Groups | 91
Chassis Cluster Redundant Ethernet Interfaces | 99

Example: Configuring an Active/Passive Chassis Cluster Pair (J-Web)

1. Enable clustering. See Step 1 in "Example: Configuring an Active/Passive Chassis Cluster Pair (CLI)"
on page 387.

2. Configure the management interface. See Step 2 in "Example: Configuring an Active/Passive Chassis
Cluster Pair (CLI)" on page 387.

3. Configure the fabric interface. See Step 3 in "Example: Configuring an Active/Passive Chassis Cluster
Pair (CLI)" on page 387.

4. Configure the redundancy groups.

• Select Configure>Chassis Cluster.

• Enter the following information, and then click Apply:

a. Redundant ether-Interface Count: 2

b. Heartbeat Interval: 1000


405

c. Heartbeat Threshold: 3

d. Nodes: 0

e. Group Number: 0

f. Priorities: 100

• Enter the following information, and then click Apply:

a. Nodes: 0

b. Group Number: 1

c. Priorities: 1

• Enter the following information, and then click Apply:

a. Nodes: 1

b. Group Number: 0

c. Priorities: 100

5. Configure the redundant Ethernet interfaces.

• Select Configure>Chassis Cluster.

• Select ge-0/0/4.

• Enter reth1 in the Redundant Parent box.

• Click Apply.

• Select ge-7/0/4.

• Enter reth1 in the Redundant Parent box.

a.

• Click Apply.

• Select ge-0/0/5.

• Enter reth0 in the Redundant Parent box.

a.

• Click Apply.

• Select ge-7/0/5.
406

• Enter reth0 in the Redundant Parent box.

a.

• Click Apply.

• See Step 5 in "Example: Configuring an Active/Passive Chassis Cluster Pair (CLI)" on page 387 for
the last four configuration settings.

6. Configure the security zones. See Step 6 in "Example: Configuring an Active/Passive Chassis Cluster
Pair (CLI)" on page 387.

7. Configure the security policies. See Step 7 in "Example: Configuring an Active/Passive Chassis
Cluster Pair (CLI)" on page 387.

8. Click OK to check your configuration and save it as a candidate configuration, then click Commit
Options>Commit.

SEE ALSO

Understanding Active/Passive Chassis Cluster Deployment | 368


Example: Configuring an Active/Passive Chassis Cluster Pair (SRX1500) | 387

Understanding Active/Passive Chassis Cluster Deployment with an IPsec


Tunnel

In this case, a single device in the cluster terminates in an IPsec tunnel and is used to process all traffic
while the other device is used only in the event of a failure (see Figure 44 on page 407). When a failure
occurs, the backup device becomes primary and controls all forwarding.
407

Figure 44: Active/Passive Chassis Cluster with IPsec Tunnel Scenario (SRX Series Firewalls)

An active/passive chassis cluster can be achieved by using redundant Ethernet interfaces (reths) that are
all assigned to the same redundancy group. If any of the interfaces in an active group in a node fails, the
group is declared inactive and all the interfaces in the group fail over to the other node.

This configuration provides a way for a site-to-site IPsec tunnel to terminate in an active/passive cluster
where a redundant Ethernet interface is used as the tunnel endpoint. In the event of a failure, the
redundant Ethernet interface in the backup SRX Series Firewall becomes active, forcing the tunnel to
change endpoints to terminate in the new active SRX Series Firewall. Because tunnel keys and session
information are synchronized between the members of the chassis cluster, a failover does not require
the tunnel to be renegotiated and all established sessions are maintained.

In case of RG0 (routing engine) failure, the routing protocols need to re-establish on the new Primary
node. If VPN monitoring or Dead-peer-detection is configured, and its timer expires before the routing
reconverges on new RG0 Primary, then VPN tunnel will be brought down and renegotiated.

Dynamic tunnels cannot load-balance across different SPCs.

SEE ALSO

IPsec VPN Overview


408

Example: Configuring an Active/Passive Chassis Cluster Pair with an


IPsec Tunnel

IN THIS SECTION

Requirements | 408

Overview | 409

Configuration | 415

Verification | 425

This example shows how to configure active/passive chassis clustering with an IPsec tunnel for SRX
Series Firewalls.

Requirements
Before you begin:

• Get two SRX5000 models with identical hardware configurations, one SRX1500 device, and four EX
Series Ethernet switches.

• Physically connect the two devices (back-to-back for the fabric and control ports) and ensure that
they are the same models. You can configure both the fabric and control ports on the SRX5000 line.

• Set the two devices to cluster mode and reboot the devices. You must enter the following
operational mode commands on both devices, for example:

• On node 0:

user@host> set chassis cluster cluster-id 1 node 0 reboot

• On node 1:

user@host> set chassis cluster cluster-id 1 node 1 reboot

The cluster ID is the same on both devices, but the node ID must be different because one device is
node 0 and the other device is node 1. The range for the cluster ID is 1 through 255. Setting a cluster
ID to 0 is equivalent to disabling a cluster.
409

Cluster ID greater than 15 can only be set when the fabric and control link interfaces are connected
back-to-back.

• Get two SRX5000 models with identical hardware configurations, one SRX1500 edge router, and
four EX Series Ethernet switches.

• Physically connect the two devices (back-to-back for the fabric and control ports) and ensure that
they are the same models. You can configure both the fabric and control ports on the SRX5000 line.

From this point forward, configuration of the cluster is synchronized between the node members and
the two separate devices function as one device. Member-specific configurations (such as the IP address
of the management port of each member) are entered using configuration groups.

Overview
In this example, a single device in the cluster terminates in an IPsec tunnel and is used to process all
traffic, and the other device is used only in the event of a failure. (See Figure 45 on page 409.) When a
failure occurs, the backup device becomes primary and controls all forwarding.

Figure 45: Active/Passive Chassis Cluster with IPsec Tunnel Topology (SRX Series Firewalls)
410

In this example, you configure group (applying the configuration with the apply-groups command) and
chassis cluster information. Then you configure IKE, IPsec, static route, security zone, and security policy
parameters. See Table 24 on page 410 through Table 30 on page 415.

Table 24: Group and Chassis Cluster Configuration Parameters

Feature Name Configuration Parameters

Groups node0 • Hostname: SRX5800-1

• Interface: fxp0

• Unit 0

• 172.19.100.50/24

node1 • Hostname: SRX5800-2

• Interface: fxp0

• Unit 0

• 172.19.100.51/24

Table 25: Chassis Cluster Configuration Parameters

Feature Name Configuration Parameters

Fabric links fab0 Interface: xe-5/3/0

fab1 Interface: xe-17/3/0

Number of redundant Ethernet interfaces – 2

Heartbeat interval – 1000

Heartbeat threshold – 3
411

Table 25: Chassis Cluster Configuration Parameters (Continued)

Feature Name Configuration Parameters

Redundancy group 0 • Priority:

• Node 0: 254

• Node 1: 1

1 • Priority:

• Node 0: 254

• Node 1: 1

Interface monitoring

• xe-5/0/0

• xe-5/1/0

• xe-17/0/0

• xe-17/1/0

Interfaces xe-5/1/0 Redundant parent: reth1

xe-5/1/0 Redundant parent: reth1

xe-5/0/0 Redundant parent: reth0

xe-17/0/0 Redundant parent: reth0

reth0 Redundancy group: 1


412

Table 25: Chassis Cluster Configuration Parameters (Continued)

Feature Name Configuration Parameters

• Unit 0

• 10.1.1.60/16

reth1 Redundancy group: 1

• Multipoint

• Unit 0

• 10.10.1.1/30

st0

• Unit 0

• 10.10.1.1/30

Table 26: IKE Configuration Parameters

Feature Name Configuration Parameters

Proposal proposal-set -
standard

Policy preShared • Mode: main

• Proposal reference: proposal-set standard

• IKE Phase 1 policy authentication method: pre-shared-key ascii-text


413

Table 26: IKE Configuration Parameters (Continued)

Feature Name Configuration Parameters

Gateway SRX1500-1 • IKE policy reference: perShared

• External interface: reth0.0

• Gateway address: 10.1.1.90

NOTE: In SRX chassis clustering, only reth and lo0 interfaces are supported for
the IKE external interface configuration. Other interface types can be
configured, but IPsec VPN might not work. If a lo0 logical interface is used as an
IKE gateway external interface, it cannot be configured with RG0.

Table 27: IPsec Configuration Parameters

Feature Name Configuration Parameters

Proposal proposal-set standard –

Policy std –

VPN SRX1500-1 • IKE gateway reference: SRX1500-1

• IPsec policy reference: std

• Bind to interface: st0.0

• VPN monitoring: vpn-monitor optimized

• Tunnels established: establish-tunnels immediately

NOTE: The manual VPN name and the site-to-site gateway name cannot be
the same.

NOTE: A secure tunnel interface (st0) from st0.16000 to st0.16385 is reserved for Multinode
High Availability and for HA control link encryption in Chassis Cluster. These interfaces are not
user configurable interfaces. You can only use interfaces from st0.0 to st0.15999.
414

Table 28: Static Route Configuration Parameters

Name Configuration Parameters

0.0.0.0/0 Next hop: 10.2.1.1

10.3.0.0/16 Next hop: 10.10.1.2

Table 29: Security Zone Configuration Parameters

Name Configuration Parameters

trust • All system services are allowed.

• All protocols are allowed.

• The reth0.0 interface is bound to this zone.

untrust • All system services are allowed.

• All protocols are allowed.

• The reth1.0 interface is bound to this zone.

vpn • All system services are allowed.

• All protocols are allowed.

• The st0.0 interface is bound to this zone.


415

Table 30: Security Policy Configuration Parameters

Purpose Name Configuration Parameters

This security policy permits traffic from the trust zone to the untrust ANY • Match criteria:
zone.
• source-address any

• destination-address any

• application any

• Action: permit

This security policy permits traffic from the trust zone to the vpn vpn-any • Match criteria:
zone.
• source-address any

• destination-address any

• application any

• Action: permit

Configuration

IN THIS SECTION

Procedure | 416
416

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set chassis cluster control-ports fpc 2 port 0
set chassis cluster control-ports fpc 14 port 0
set groups node0 system host-name SRX5800-1
set groups node0 interfaces fxp0 unit 0 family inet address 172.19.100.50/24
set groups node1 system host-name SRX5800-2
set groups node1 interfaces fxp0 unit 0 family inet address 172.19.100.51/24
set apply-groups “${node}”
set interfaces fab0 fabric-options member-interfaces xe-5/3/0
set interfaces fab1 fabric-options member-interfaces xe-17/3/0
set chassis cluster reth-count 2
set chassis cluster heartbeat-interval 1000
set chassis cluster heartbeat-threshold 3
set chassis cluster node 0
set chassis cluster node 1
set chassis cluster redundancy-group 0 node 0 priority 254
set chassis cluster redundancy-group 0 node 1 priority 1
set chassis cluster redundancy-group 1 node 0 priority 254
set chassis cluster redundancy-group 1 node 1 priority 1
set chassis cluster redundancy-group 1 preempt
set chassis cluster redundancy-group 1 interface-monitor xe-5/0/0 weight 255
set chassis cluster redundancy-group 1 interface-monitor xe-5/1/0 weight 255
set chassis cluster redundancy-group 1 interface-monitor xe-17/0/0 weight 255
set chassis cluster redundancy-group 1 interface-monitor xe-17/1/0 weight 255
set interfaces xe-5/1/0 gigether-options redundant-parent reth1
set interfaces xe-17/1/0 gigether-options redundant-parent reth1
set interfaces xe-5/0/0 gigether-options redundant-parent reth0
set interfaces xe-17/0/0 gigether-options redundant-parent reth0
set interfaces reth0 redundant-ether-options redundancy-group 1
set interfaces reth0 unit 0 family inet address 10.1.1.60/16
set interfaces reth1 redundant-ether-options redundancy-group 1
set interfaces reth1 unit 0 family inet address 10.2.1.60/16
set interfaces st0 unit 0 multipoint family inet address 10.10.1.1/30
set security ike policy preShared mode main
417

set security ike policy preShared proposal-set standard


set security ike policy preShared pre-shared-key ascii-text "$ABC123"## Encrypted password
set security ike gateway SRX1500-1 ike-policy preShared
set security ike gateway SRX1500-1 address 10.1.1.90
set security ike gateway SRX1500-1 external-interface reth0.0
set security ipsec policy std proposal-set standard
set security ipsec vpn SRX1500-1 bind-interface st0.0
set security ipsec vpn SRX1500-1 vpn-monitor optimized
set security ipsec vpn SRX1500-1 ike gateway SRX1500-1
set security ipsec vpn SRX1500-1 ike ipsec-policy std
set security ipsec vpn SRX1500-1 establish-tunnels immediately
set routing-options static route 0.0.0.0/0 next-hop 10.2.1.1
set routing-options static route 10.3.0.0/16 next-hop 10.10.1.2
set security zones security-zone untrust host-inbound-traffic system-services all
set security zones security-zone untrust host-inbound-traffic protocols all
set security zones security-zone untrust interfaces reth1.0
set security zones security-zone trust host-inbound-traffic system-services all
set security zones security-zone trust host-inbound-traffic protocols all
set security zones security-zone trust interfaces reth0.0
set security zones security-zone vpn host-inbound-traffic system-services all 144
set security zones security-zone vpn host-inbound-traffic protocols all
set security zones security-zone vpn interfaces st0.0
set security policies from-zone trust to-zone untrust policy ANY match source-address any
set security policies from-zone trust to-zone untrust policy ANY match destination-address any
set security policies from-zone trust to-zone untrust policy ANY match application any
set security policies from-zone trust to-zone vpn policy vpn-any then permit

Step-by-Step Procedure

To configure an active/passive chassis cluster pair with an IPsec tunnel:

1. Configure control ports.

{primary:node0}[edit]
user@host# set chassis cluster control-ports fpc 2 port 0
user@host# set chassis cluster control-ports fpc 14 port 0

2. Configure the management interface.

{primary:node0}[edit]
user@host# set groups node0 system host-name SRX5800-1
418

user@host# set groups node0 interfaces fxp0 unit 0 family inet address 172.19.100.50/24
user@host#set groups node1 system host-name SRX5800-2
user@host# set groups node1 interfaces fxp0 unit 0 family inet address 172.19.100.51/24
user@host# set apply-groups “${node}”

3. Configure the fabric interface.

{primary:node0}[edit]
user@host# set interfaces fab0 fabric-options member-interfaces xe-5/3/0
user@host# set interfaces fab1 fabric-options member-interfaces xe-17/3/0

4. Configure redundancy groups.

{primary:node0}[edit]
user@host# set chassis cluster reth-count 2
user@host# set chassis cluster heartbeat-interval 1000
user@host# set chassis cluster heartbeat-threshold 3
user@host# set chassis cluster node 0
user@host# set chassis cluster node 1
user@host# set chassis cluster redundancy-group 0 node 0 priority 254
user@host# set chassis cluster redundancy-group 0 node 1 priority 1
user@host# set chassis cluster redundancy-group 1 node 0 priority 254
user@host# set chassis cluster redundancy-group 1 node 1 priority 1
user@host# set chassis cluster redundancy-group 1 preempt
user@host# set chassis cluster redundancy-group 1 interface-monitor xe-5/0/0 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor xe-5/1/0 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor xe-17/0/0 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor xe-17/1/0 weight 255

5. Configure redundant Ethernet interfaces.

{primary:node0}[edit]
user@host# set interfaces xe-5/1/0 gigether-options redundant-parent reth1
user@host# set interfaces xe-17/1/0 gigether-options redundant-parent reth1
user@host# set interfaces xe-5/0/0 gigether-options redundant-parent reth0
user@host# set interfaces xe-17/0/0 gigether-options redundant-parent reth0
user@host# set interfaces reth0 redundant-ether-options redundancy-group 1
user@host# set interfaces reth0 unit 0 family inet address 10.1.1.60/16
419

user@host# set interfaces reth1 redundant-ether-options redundancy-group 1


user@host# set interfaces reth1 unit 0 family inet address 10.2.1.60/16

6. Configure IPsec parameters.

{primary:node0}[edit]
user@host# set interfaces st0 unit 0 multipoint family inet address 10.10.1.1/30
user@host# set security ike policy preShared mode main
user@host# set security ike policy preShared proposal-set standard
user@host# set security ike policy preShared pre-shared-key ascii-text "$ABC123"## Encrypted
password
user@host# set security ike gateway SRX1500-1 ike-policy preShared
user@host# set security ike gateway SRX1500-1 address 10.1.1.90
user@host# set security ike gateway SRX1500-1 external-interface reth0.0
user@host# set security ipsec policy std proposal-set standard
user@host# set security ipsec vpn SRX1500-1 bind-interface st0.0
user@host# set security ipsec vpn SRX1500-1 vpn-monitor optimized
user@host# set security ipsec vpn SRX1500-1 ike gateway SRX1500-1
user@host# set security ipsec vpn SRX1500-1 ike ipsec-policy std
user@host# set security ipsec vpn SRX1500-1 establish-tunnels immediately

7. Configure static routes.

{primary:node0}[edit]
user@host# set routing-options static route 0.0.0.0/0 next-hop 10.2.1.1
user@host# set routing-options static route 10.3.0.0/16 next-hop 10.10.1.2

8. Configure security zones.

{primary:node0}[edit]
user@host# set security zones security-zone untrust host-inbound-traffic system-services all
user@host# set security zones security-zone untrust host-inbound-traffic protocols all
user@host# set security zones security-zone untrust interfaces reth1.0
user@host# set security zones security-zone trust host-inbound-traffic system-services all
user@host# set security zones security-zone trust host-inbound-traffic protocols all
user@host# set security zones security-zone trust interfaces reth0.0
user@host# set security zones security-zone vpn host-inbound-traffic system-services all
user@host# set security zones security-zone vpn host-inbound-traffic protocols all
user@host# set security zones security-zone vpn interfaces st0.0
420

9. Configure security policies.

{primary:node0}[edit]
user@host# set security policies from-zone trust to-zone untrust policy ANY match source-
address any
user@host# set security policies from-zone trust to-zone untrust policy ANY match destination-
address any
user@host# set security policies from-zone trust to-zone untrust policy ANY match application
any
user@host# set security policies from-zone trust to-zone vpn policy vpn-any then permit

Results

From operational mode, confirm your configuration by entering the show configuration command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

user@host> show configuration


version x.xx.x;
groups {
node0 {
system {
host-name SRX58001;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 172.19.100.50/24;
}
}
}
}
}
node1 {
system {
host-name SRX58002;
}
421

interfaces {
fxp0 {
unit 0 {
family inet {
address 172.19.100.51/24;
}
}
}
}
}
}
apply-groups "${node}";
system {
root-authentication {
encrypted-password "$ABC123";
}
}
chassis {
cluster {
reth-count 2;
heartbeat-interval 1000;
heartbeat-threshold 3;
control-ports {
fpc 2 port 0;
fpc 14 port 0;
}
redundancy-group 0 {
node 0 priority 254;
node 1 priority 1;
}
redundancy-group 1 {
node 0 priority 254;
node 1 priority 1;
preempt;
interface-monitor {
xe–6/0/0 weight 255;
xe–6/1/0 weight 255;
xe–18/0/0 weight 255;
xe–18/1/0 weight 255;
}
}
}
}
422

interfaces {
xe–5/0/0 {
gigether–options {
redundant–parent reth0;
}
}
xe–5/1/0 {
gigether–options {
redundant–parent reth1;
}
}
xe–17/0/0 {
gigether–options {
redundant–parent reth0;
}
}
xe–17/1/0 {
gigether–options {
redundant–parent reth1;
}
}
fab0 {
fabric–options {
member–interfaces {
xe–5/3/0;
}
}
}
fab1 {
fabric–options {
member–interfaces {
xe–17/3/0;
}
}
}
reth0 {
redundant–ether–options {
redundancy–group 1;
}
unit 0 {
family inet {
address 10.1.1.60/16;
}
423

}
}
reth1 {
redundant–ether–options {
redundancy–group 1;
}
unit 0 {
family inet {
address 10.2.1.60/16;
}
}
}
st0 {
unit 0 {
multipoint;
family inet {
address 5.4.3.2/32;
}
}
}
}
routing–options {
static {
route 0.0.0.0/0 {
next–hop 10.2.1.1;
}
route 10.3.0.0/16 {
next–hop 10.10.1.2;
}
}
}
security {
zones {
security–zone trust {
host–inbound–traffic {
system–services {
all;
}
}
interfaces {
reth0.0;
}
}
424

security–zone untrust
host-inbound-traffic {
system-services {
all;
}
}
protocols {
all;
}
interfaces {
reth1.0;
}
}

security-zone vpn {
host-inbound-traffic {
system-services {
all;
}
}
protocols {
all;
}
interfaces {
st0.0;
}

}
}
policies {
from–zone trust to–zone untrust {
policy ANY {
match {
source–address any;
destination–address any;
application any;
}
then {
permit;
}
}
}
from–zone trust to–zone vpn {
425

policy vpn {
match {
source–address any;
destination–address any;
application any;
}
then {
permit;
}
}
}
}
}

If you are done configuring the device, enter commit from configuration mode.

Verification

IN THIS SECTION

Verifying Chassis Cluster Status | 425

Verifying Chassis Cluster Interfaces | 426

Verifying Chassis Cluster Statistics | 427

Verifying Chassis Cluster Control Plane Statistics | 428

Verifying Chassis Cluster Data Plane Statistics | 428

Verifying Chassis Cluster Redundancy Group Status | 429

Troubleshooting with Logs | 430

Confirm that the configuration is working properly.

Verifying Chassis Cluster Status

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.
426

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
show chassis cluster status
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 1 primary no no
node1 254 secondary no no

Redundancy group: 1 , Failover count: 1


node0 1 primary yes no
node1 254 secondary yes no

Verifying Chassis Cluster Interfaces

Purpose

Verify the chassis cluster interfaces.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link name: fxp1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1

Interface Monitoring:
Interface Weight Status Redundancy-group
xe-5/0/0 255 Up 1
xe-5/1/0 255 Up 1
427

xe-17/0/0 255 Up 1
xe-17/1/0 255 Up 1

Verifying Chassis Cluster Statistics

Purpose

Verify information about chassis cluster services and control link statistics (heartbeats sent and
received), fabric link statistics (probes sent and received), and the number of RTOs sent and received for
services.

Action

From operational mode, enter the show chassis cluster statistics command.

{primary:node0}
user@host> show chassis cluster statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 258689
Heartbeat packets received: 258684
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 258681
Probes received: 258681
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 6 0
Session create 161 0
Session close 148 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
428

H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Verifying Chassis Cluster Control Plane Statistics

Purpose

Verify information about chassis cluster control plane statistics (heartbeats sent and received) and the
fabric link statistics (probes sent and received).

Action

From operational mode, enter the show chassis cluster control-panel statistics command.

{primary:node0}
user@host> show chassis cluster control-plane statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 258689
Heartbeat packets received: 258684
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 258681
Probes received: 258681

Verifying Chassis Cluster Data Plane Statistics

Purpose

Verify information about the number of RTOs sent and received for services.
429

Action

From operational mode, enter the show chassis cluster data-plane statistics command.

{primary:node0}
user@host> show chassis cluster data-plane statistics

Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 6 0
Session create 161 0
Session close 148 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Verifying Chassis Cluster Redundancy Group Status

Purpose

Verify the state and priority of both nodes in a cluster and information about whether the primary node
has been preempted or whether there has been a manual failover.
430

Action

From operational mode, enter the chassis cluster status redundancy-group command.

{primary:node0}
user@host> show chassis cluster status redundancy-group 1
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy-Group: 1, Failover count: 1


node0 0 primary yes no
node1 254 secondary yes no

Troubleshooting with Logs

Purpose

Use these logs to identify any chassis cluster issues. You must run these logs on both nodes.

Action

From operational mode, enter these show commands.

user@host> show log jsrpd


user@host> show log chassisd
user@host> show log messages
user@host> show log dcd
user@host> show traceoptions

Example: Configuring an Active/Passive Chassis Cluster Pair with an


IPsec Tunnel (J-Web)

1. Enable clusters. See Step 1 in "Example: Configuring an Active/Passive Chassis Cluster Pair with an
IPsec Tunnel" on page 408.

2. Configure the management interface. See Step 2 in "Example: Configuring an Active/Passive


Chassis Cluster Pair with an IPsec Tunnel" on page 408.
431

3. Configure the fabric interface. See Step 3 in "Example: Configuring an Active/Passive Chassis
Cluster Pair with an IPsec Tunnel" on page 408.

4. Configure the redundancy groups.

• Select Configure>System Properties>Chassis Cluster.

• Enter the following information, and then click Apply:

a. Redundant ether-Interfaces Count: 2

b. Heartbeat Interval: 1000

c. Heartbeat Threshold: 3

d. Nodes: 0

e. Group Number: 0

f. Priorities: 254

• Enter the following information, and then click Apply:

a. Nodes: 0

b. Group Number: 1

c. Priorities: 254

• Enter the following information, and then click Apply:

a. Nodes: 1

b. Group Number: 0

c. Priorities: 1

• Enter the following information, and then click Apply:

a. Nodes: 1

b. Group Number: 1

c. Priorities: 1

d. Preempt: Select the check box.

e. Interface Monitor—Interface: xe-5/0/0

f. Interface Monitor—Weight: 255


432

g. Interface Monitor—Interface: xe-5/1/0

h. Interface Monitor—Weight: 255

i. Interface Monitor—Interface: xe-17/0/0

j. Interface Monitor—Weight: 255

k. Interface Monitor—Interface: xe-17/1/0

l. Interface Monitor—Weight: 255

5. Configure the redundant Ethernet interfaces.

• Select Configure>System Properties>Chassis Cluster.

• Select xe-5/1/0.

• Enter reth1 in the Redundant Parent box.

• Click Apply.

• Select xe-17/1/0.

• Enter reth1 in the Redundant Parent box.

• Click Apply.

• Select xe-5/0/0.

• Enter reth0 in the Redundant Parent box.

• Click Apply.

• Select xe-17/0/0.

• Enter reth0 in the Redundant Parent box.

• Click Apply.

• See Step 5 in "Example: Configuring an Active/Passive Chassis Cluster Pair with an IPsec Tunnel"
on page 408.

6. Configure the IPsec configuration. See Step 6 in "Example: Configuring an Active/Passive Chassis
Cluster Pair with an IPsec Tunnel" on page 408.

7. Configure the static routes .

• Select Configure>Routing>Static Routing.


433

• Click Add.

• Enter the following information, and then click Apply:

a. Static Route Address: 0.0.0.0/0

b. Next-Hop Addresses: 10.2.1.1

• Enter the following information, and then click Apply:

a. Static Route Address: 10.3.0.0/16

b. Next-Hop Addresses: 10.10.1.2

8. Configure the security zones. See Step 8 in "Example: Configuring an Active/Passive Chassis
Cluster Pair with an IPsec Tunnel" on page 408.

9. Configure the security policies. See Step 9 in "Example: Configuring an Active/Passive Chassis
Cluster Pair with an IPsec Tunnel" on page 408.

10. Click OK to check your configuration and save it as a candidate configuration, then click Commit
Options>Commit.

RELATED DOCUMENTATION

SRX Series Chassis Cluster Configuration Overview | 13


Configuring Chassis Clustering on SRX Series Devices | 129

Multicast Routing and Asymmetric Routing on


Chassis Cluster

IN THIS SECTION

Understanding Multicast Routing on a Chassis Cluster | 434

Understanding Asymmetric Routing on a Chassis Cluster | 435

Example: Configuring an Asymmetric Chassis Cluster Pair | 437


434

Multicast routing support in a chassis cluster allows different multicast protocols to send traffic across
interfaces to multiple recipients. Asymmetric routing is the situation where packets from source host to
destination host but follow a different path than packets from destination host to source host. For more
information, see the following topics:

Understanding Multicast Routing on a Chassis Cluster

IN THIS SECTION

Understanding PIM Data Forwarding | 435

Understanding Multicast and PIM Session Synchronization | 435

Multicast routing support across nodes in a chassis cluster allows multicast protocols, such as Protocol
Independent Multicast (PIM) versions 1 and 2, Internet Group Management Protocol (IGMP), Session
Announcement Protocol (SAP), and Distance Vector Multicast Routing Protocol (DVMRP), to send traffic
across interfaces in the cluster. Note, however, that the multicast protocols should not be enabled on
the chassis management interface (fxp0) or on the fabric interfaces (fab0 and fab1). Multicast sessions are
synched across the cluster and maintained during redundant group failovers. During failover, as with
other types of traffic, there might be some multicast packet loss.

Multicast data forwarding in a chassis cluster uses the incoming interface to determine whether or not
the session remains active. Packets are forwarded to the peer node if a leaf session’s outgoing interface
is on the peer instead of on the incoming interface’s node. Multicast routing on a chassis cluster
supports tunnels for both incoming and outgoing interfaces.

Multicast traffic has an upstream (toward source) and downstream (toward subscribers) direction in
traffic flows. The devices replicate (fanout) a single multicast packet to multiple networks that contain
subscribers. In the chassis cluster environment, multicast packet fanouts can be active on either nodes.

If the incoming interface is active on the current node and backup on the peer node, then the session is
active on the current node and backup on the peer node.

Multicast configuration on a chassis cluster is the same as multicast configuration on a standalone


device. See the Multicast Protocols User Guide for more information.
435

Understanding PIM Data Forwarding

Protocol Independent Multicast (PIM) is used between devices to track the multicast packets to be
forwarded to each other.

A PIM session encapsulates multicast data into a PIM unicast packet. A PIM session creates the
following sessions:

• Control session

• Data session

The data session saves the control session ID. The control session and the data session are closed
independently. The incoming interface is used to determine whether the PIM session is active or not. If
the outgoing interface is active on the peer node, packets are transferred to the peer node for
transmission.

Understanding Multicast and PIM Session Synchronization

Synchronizing multicast and PIM sessions helps to prevent packet loss due to failover because the
sessions do not need to be set up again when there is a failover.

In PIM sessions, the control session is synchronized to the backup node, and then the data session is
synchronized.

In multicast sessions, the template session is synchronized to the peer node, then all the leaf sessions
are synchronized, and finally the template session is synchronized again.

SEE ALSO

Chassis Cluster Overview | 2

Understanding Asymmetric Routing on a Chassis Cluster

IN THIS SECTION

Understanding Failures in the Trust Zone Redundant Ethernet Interface | 436

Understanding Failures in the Untrust Zone Interfaces | 437


436

You can use SRX Series Firewalls in chassis clusters asymmetric routing scenarios (see Figure 46 on page
436). Traffic received by a node is matched against that node’s session table. The result of this lookup
determines whether or not that the node processes the packet or forwards it to the other node over the
fabric link. Sessions are anchored on the egress node for the first packet that created the session. If
traffic is received on the node in which the session is not anchored, those packets are forwarded over
the fabric link to the node where the session is anchored.

The anchor node for the session can change if there are changes in routing during the session.

Figure 46: Asymmetric Routing Chassis Cluster Scenario

In this scenario, two Internet connections are used, with one being preferred. The connection to the
trust zone is done by using a redundant Ethernet interface to provide LAN redundancy for the devices in
the trust zone. This scenario describes two failover cases in which sessions originate in the trust zone
with a destination of the Internet (untrust zone).

Understanding Failures in the Trust Zone Redundant Ethernet Interface

Under normal operating conditions, traffic flows from the trust zone interface ge-0/0/1, belonging to
reth0.0, to the Internet. Because the primary Internet connection is on node 0, sessions are created in
node 0 and synced to node 1. However, sessions are only active on node 0.

A failure in interface ge-0/0/1 triggers a failover of the redundancy group, causing interface ge-7/0/1 in
node 1 to become active. After the failover, traffic arrives at node 1. After session lookup, the traffic is
437

sent to node 0 because the session is active on this node. Node 0 then processes the traffic and
forwards it to the Internet. The return traffic follows a similar process. The traffic arrives at node 0 and
gets processed for security purposes—for example, antispam scanning, antivirus scanning, and
application of security policies—on node 0 because the session is anchored to node 0. The packet is
then sent to node 1 through the fabric interface for egress processing and eventual transmission out of
node 1 through interface ge-7/0/1.

Understanding Failures in the Untrust Zone Interfaces

In this case, sessions are migrated from node to node. Under normal operating conditions, traffic is
processed by only node 0. A failure of interface ge-0/0/0 on node 0 causes a change in the routing
table, so that it now points to interface ge-7/0/0 in node 1. After the failure, sessions in node 0 become
inactive, and the passive sessions in node 1 become active. Traffic arriving from the trust zone is still
received on interface ge-0/0/1, but is forwarded to node 1 for processing. After traffic is processed in
node 1, it is forwarded to the Internet through interface ge-7/0/0.

In this chassis cluster configuration, redundancy group 1 is used to control the redundant Ethernet
interface connected to the trust zone. As configured in this scenario, redundancy group 1 fails over only
if interface ge-0/0/1 or ge-7/0/1 fails, but not if the interfaces connected to the Internet fail. Optionally,
the configuration could be modified to permit redundancy group 1 to monitor all interfaces connected
to the Internet and fail over if an Internet link were to fail. So, for example, the configuration can allow
redundancy group 1 to monitor ge-0/0/0 and make ge-7/0/1 active for reth0 if the ge-0/0/0 Internet
link fails. (This option is not described in the following configuration examples.)

SEE ALSO

Chassis Cluster Overview | 2

Example: Configuring an Asymmetric Chassis Cluster Pair

IN THIS SECTION

Requirements | 438

Overview | 438

Configuration | 442

Verification | 449
438

This example shows how to configure a chassis cluster to allow asymmetric routing. Configuring
asymmetric routing for a chassis cluster allows traffic received on either device to be processed
seamlessly.

Requirements
Before you begin:

1. Physically connect a pair of devices together, ensuring that they are the same models. This example
uses a pair of SRX1500 devices.

a. To create the fabric link, connect a Gigabit Ethernet interface on one device to another Gigabit
Ethernet interface on the other device.

b. To create the control link, connect the control port of the two SRX1500 devices.

2. Connect to one of the devices using the console port. (This is the node that forms the cluster.)

a. Set the cluster ID and node number.

user@host> set chassis cluster cluster-id 1 node 0 reboot

3. Connect to the other device using the console port.

a. Set the cluster ID and node number.

user@host> set chassis cluster cluster-id 1 node 1 reboot

Overview
In this example, a chassis cluster provides asymmetric routing. As illustrated in Figure 47 on page 439,
two Internet connections are used, with one being preferred. The connection to the trust zone is
provided by a redundant Ethernet interface to provide LAN redundancy for the devices in the trust zone.
439

Figure 47: Asymmetric Routing Chassis Cluster Topology

In this example, you configure group (applying the configuration with the apply-groups command) and
chassis cluster information. Then you configure security zones and security policies. See Table 31 on
page 439 through Table 34 on page 442.

Table 31: Group and Chassis Cluster Configuration Parameters

Feature Name Configuration Parameters

Groups node0 • Hostname: srxseries-1

• Interface: fxp0

• Unit 0

• 192.168.100.50/24
440

Table 31: Group and Chassis Cluster Configuration Parameters (Continued)

Feature Name Configuration Parameters

node1 • Hostname: srxseries-2

• Interface: fxp0

• Unit 0

• 192.168.100.51/24

Table 32: Chassis Cluster Configuration Parameters

Feature Name Configuration Parameters

Fabric links fab0 Interface: ge-0/0/7

fab1 Interface: ge-7/0/7

Heartbeat interval – 1000

Heartbeat threshold – 3

Redundancy group 1 • Priority:

• Node 0: 100

• Node 1: 1

Interface monitoring

• ge-0/0/3

• ge-7/0/3

Number of redundant Ethernet interfaces – 1


441

Table 32: Chassis Cluster Configuration Parameters (Continued)

Feature Name Configuration Parameters

Interfaces ge-0/0/1 • Unit 0

• 10.4.0.202/24

ge-7/0/1 • Unit 0

• 10.2.1.233/24

ge-0/0/3 •

Redundant parent: reth0

ge-7/0/3 •

Redundant parent: reth0

reth0 • Unit 0

• 10.16.8.1/24

Table 33: Security Zone Configuration Parameters

Name Configuration Parameters

trust The reth0.0 interface is bound to this zone.

untrust The ge-0/0/1 and ge-7/0/1 interfaces are bound to this zone.
442

Table 34: Security Policy Configuration Parameters

Purpose Name Configuration Parameters

This security policy permits traffic from the trust zone to the untrust ANY • Match criteria:
zone.
• source-address any

• destination-address any

• application any

• Action: permit

Configuration

IN THIS SECTION

Procedure | 442

Procedure

CLI Quick Configuration

To quickly configure this example, copy the following commands, paste them into a text file, remove any
line breaks, change any details necessary to match your network configuration, copy and paste the
commands into the CLI at the [edit] hierarchy level, and then enter commit from configuration mode.

{primary:node0}[edit]
set groups node0 system host-name srxseries-1
set groups node0 interfaces fxp0 unit 0 family inet address 192.168.100.50/24
set groups node1 system host-name srxseries-2
set groups node1 interfaces fxp0 unit 0 family inet address 192.168.100.51/24
set apply-groups “${node}”
set interfaces fab0 fabric-options member-interfaces ge-0/0/7
set interfaces fab1 fabric-options member-interfaces ge-7/0/7
set chassis cluster reth-count 1
set chassis cluster heartbeat-interval 1000
443

set chassis cluster heartbeat-threshold 3


set chassis cluster redundancy-group 1 node 0 priority 100
set chassis cluster redundancy-group 1 node 1 priority 1
set chassis cluster redundancy-group 1 interface-monitor ge-0/0/3 weight 255
set chassis cluster redundancy-group 1 interface-monitor ge-7/0/3 weight 255
set interfaces ge-0/0/1 unit 0 family inet address 1.4.0.202/24
set interfaces ge-0/0/3 gigether-options redundant-parent reth0
set interfaces ge-7/0/1 unit 0 family inet address 10.2.1.233/24
set interfaces ge-7/0/3 gigether-options redundant-parent reth0
set interfaces reth0 unit 0 family inet address 10.16.8.1/24
set routing-options static route 0.0.0.0/0 qualified-next-hop 10.4.0.1 metric 10
set routing-options static route 0.0.0.0/0 qualified-next-hop 10.2.1.1 metric 100
set security zones security-zone untrust interfaces ge-0/0/1.0
set security zones security-zone untrust interfaces ge-7/0/1.0
set security zones security-zone trust interfaces reth0.0
set security policies from-zone trust to-zone untrust policy ANY match source-address any
set security policies from-zone trust to-zone untrust policy ANY match destination-address any
set security policies from-zone trust to-zone untrust policy ANY match application any
set security policies from-zone trust to-zone untrust policy ANY then permit

Step-by-Step Procedure

To configure an asymmetric chassis cluster pair:

1. Configure the management interface.

{primary:node0}[edit]
user@host# set groups node0 system host-name srxseries-1
user@host# set groups node0 interfaces fxp0 unit 0 family inet address 192.168.100.50/24
user@host# set groups node1 system host-name srxseries-2
user@host#set groups node1 interfaces fxp0 unit 0 family inet address 192.168.100.51/24
user@host# set apply-groups “${node}”

2. Configure the fabric interface.

{primary:node0}[edit]
user@host# set interfaces fab0 fabric-options member-interfaces ge-0/0/7
user@host# set interfaces fab1 fabric-options member-interfaces ge-7/0/7
444

3. Configure the number of redundant Ethernet interfaces.

{primary:node0}[edit]
user@host# set chassis cluster reth-count 1

4. Configure the redundancy groups.

{primary:node0}[edit]
user@host# set chassis cluster heartbeat-interval 1000
user@host# set chassis cluster heartbeat-threshold 3
user@host# set chassis cluster node 0
user@host# set chassis cluster node 1
user@host# set chassis cluster redundancy-group 1 node 0 priority 100
user@host# set chassis cluster redundancy-group 1 node 1 priority 1
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-0/0/3 weight 255
user@host# set chassis cluster redundancy-group 1 interface-monitor ge-7/0/3 weight 255

5. Configure the redundant Ethernet interfaces.

{primary:node0}[edit]
user@host# set interfaces ge-0/0/1 unit 0 family inet address 1.4.0.202/24
user@host# set interfaces ge-0/0/3 gigether-options redundant-parent reth0
user@host# set interfaces ge-7/0/1 unit 0 family inet address 10.2.1.233/24
user@host# set interfaces ge-7/0/3 gigether-options redundant-parent reth0
user@host# set interfaces reth0 unit 0 family inet address 10.16.8.1/24

6. Configure the static routes (one to each ISP, with preferred route through ge-0/0/1).

{primary:node0}[edit]
user@host# set routing-options static route 0.0.0.0/0 qualified-next-hop 10.4.0.1 metric 10
user@host# set routing-options static route 0.0.0.0/0 qualified-next-hop 10.2.1.1 metric 100

7. Configure the security zones.

{primary:node0}[edit]
user@host# set security zones security-zone untrust interfaces ge-0/0/1.0
445

user@host# set security zones security-zone untrust interfaces ge-7/0/1.0


user@host# set security zones security-zone trust interfaces reth0.0

8. Configure the security policies.

{primary:node0}[edit]
user@host# set security policies from-zone trust to-zone untrust policy ANY match source-
address any
user@host# set security policies from-zone trust to-zone untrust policy ANY match destination-
address any
user@host# set security policies from-zone trust to-zone untrust policy ANY match application
any
user@host# set security policies from-zone trust to-zone untrust policy ANY then permit

Results

From operational mode, confirm your configuration by entering the show configuration command. If the
output does not display the intended configuration, repeat the configuration instructions in this example
to correct it.

For brevity, this show command output includes only the configuration that is relevant to this example.
Any other configuration on the system has been replaced with ellipses (...).

user@host> show configuration


version x.xx.x;
groups {
node0 {
system {
host-name srxseries-1;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.100.50/24;
}
}
}
}
}
node1 {
446

system {
host-name srxseries-2;
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.100.51/24;
}
}
}
}
}
}
apply-groups "${node}";
chassis {
cluster {
reth-count 1;
heartbeat-interval 1000;
heartbeat-threshold 3;
redundancy-group 1 {
node 0 priority 100;
node 1 priority 1;
interface-monitor {
ge-0/0/3 weight 255;
ge-7/0/3 weight 255;
}
}
}
}
interfaces {
ge-0/0/3 {
gigether–options {
redundant–parent reth0;
}
}
ge-7/0/3 {
gigether–options {
redundant–parent reth0;
}
}
ge–0/0/1 {
unit 0 {
family inet {
447

address 10.4.0.202/24;
}
}
}
ge–7/0/1 {
unit 0 {
family inet {
address 10.2.1.233/24;
}
}
}
fab0 {
fabric–options {
member–interfaces {
ge–0/0/7;
}
}
}
fab1 {
fabric–options {
member–interfaces {
ge–7/0/7;
}
}
}
reth0 {
gigether–options {
redundancy–group 1;
}
unit 0 {
family inet {
address 10.16.8.1/24;
}
}
}
}
...
routing-options {
static {
route 0.0.0.0/0 {
next-hop 10.4.0.1;
metric 10;
}
448

}
}
routing-options {
static {
route 0.0.0.0/0 {
next-hop 10.2.1.1;
metric 100;
}
}
}
security {
zones {
security–zone untrust {
interfaces {
ge-0/0/1.0;
ge-7/0/1.0;
}
}
security–zone trust {
interfaces {
reth0.0;
}
}
}
policies {
from-zone trust to-zone untrust {
policy ANY {
match {
source-address any;
destination-address any;
application any;
}
then {
permit;
}
}
}
}
}

If you are done configuring the device, enter commit from configuration mode.
449

Verification

IN THIS SECTION

Verifying Chassis Cluster Status | 449

Verifying Chassis Cluster Interfaces | 450

Verifying Chassis Cluster Statistics | 450

Verifying Chassis Cluster Control Plane Statistics | 451

Verifying Chassis Cluster Data Plane Statistics | 452

Verifying Chassis Cluster Redundancy Group Status | 453

Troubleshooting with Logs | 453

Confirm that the configuration is working properly.

Verifying Chassis Cluster Status

Purpose

Verify the chassis cluster status, failover status, and redundancy group information.

Action

From operational mode, enter the show chassis cluster status command.

{primary:node0}
user@host> show chassis cluster status
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 1 , Failover count: 1


node0 100 primary no no
node1 1 secondary no no
450

Verifying Chassis Cluster Interfaces

Purpose

Verify information about chassis cluster interfaces.

Action

From operational mode, enter the show chassis cluster interfaces command.

{primary:node0}
user@host> show chassis cluster interfaces
Control link name: fxp1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-0/0/3 255 Up 1
ge-7/0/3 255 Up 1

Verifying Chassis Cluster Statistics

Purpose

Verify information about the statistics of the different objects being synchronized, the fabric and control
interface hellos, and the status of the monitored interfaces in the cluster.

Action

From operational mode, enter the show chassis cluster statistics command.

{primary:node0}
user@host> show chassis cluster statistics

Control link statistics:


Control link 0:
451

Heartbeat packets sent: 228


Heartbeat packets received: 2370
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 2272
Probes received: 597
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 6 0
Session create 160 0
Session close 147 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Verifying Chassis Cluster Control Plane Statistics

Purpose

Verify information about chassis cluster control plane statistics (heartbeats sent and received) and the
fabric link statistics (probes sent and received).
452

Action

From operational mode, enter the show chassis cluster control-plane statistics command.

{primary:node0}
user@host> show chassis cluster control-plane statistics

Control link statistics:


Control link 0:
Heartbeat packets sent: 258689
Heartbeat packets received: 258684
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 258681
Probes received: 258681

Verifying Chassis Cluster Data Plane Statistics

Purpose

Verify information about the number of RTOs sent and received for services.

Action

From operational mode, enter the show chassis cluster data-plane statistics command.

{primary:node0}
user@host> show chassis cluster data-plane statistics

Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 6 0
Session create 160 0
Session close 147 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
453

Session ageout refresh replies 0 0


IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Verifying Chassis Cluster Redundancy Group Status

Purpose

Verify the state and priority of both nodes in a cluster and information about whether the primary node
has been preempted or whether there has been a manual failover.

Action

From operational mode, enter the chassis cluster status redundancy-group command.

{primary:node0}
user@host> show chassis cluster status redundancy-group 1
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy-Group: 1, Failover count: 1


node0 100 primary no no
node1 1 secondary no no

Troubleshooting with Logs

Purpose

Use these logs to identify any chassis cluster issues. You must run these logs on both nodes.
454

Action

From operational mode, enter these show commands.

user@host> show log jsrpd


user@host> show log chassisd
user@host> show log messages
user@host> show log dcd
user@host> show traceoptions

RELATED DOCUMENTATION

Chassis Cluster Overview | 2


Configuring Chassis Clustering on SRX Series Devices | 129

Ethernet Switching on Chassis Cluster

IN THIS SECTION

Layer 2 Ethernet Switching Capability in a Chassis Cluster Mode | 455

Example: Configuring Switch Fabric Interfaces to Enable Switching in Chassis Cluster Mode on a Security
Device | 456

Example: Configure IRB and VLAN with Members Across Two Nodes on a Security Device using Tagged
| 460

Example: Configure IRB and VLAN with Members Across Two Nodes on a Security Device using Untagged
Traffic | 470

Example: Configuring VLAN with Members Across Two Nodes on a Security Device | 480

You can configure a chassis cluster to act as a Layer 2 Ethernet switch. For more information, see the
following topics:.
455

Layer 2 Ethernet Switching Capability in a Chassis Cluster Mode

IN THIS SECTION

Understanding Layer 2 Ethernet Switching Capability in a Chassis Cluster on SRX Series Devices | 455

Understanding Chassis Cluster Failover and New Primary Election | 455

Benefits of Ethernet Switching on Chassis Cluster | 456

Understanding Layer 2 Ethernet Switching Capability in a Chassis Cluster on SRX


Series Devices

Ethernet ports support various Layer 2 features such as spanning-tree protocols (STPs), IEEE 802.1x,
Link Layer Discovery Protocol (LLDP), and Multiple VLAN Registration Protocol (MVRP). With the
extension of Layer 2 switching capability to devices in a chassis cluster, you can use Ethernet switching
features on both nodes of a chassis cluster.

To ensure that Layer 2 switching works seamlessly across chassis cluster nodes, a dedicated physical link
connecting the nodes is required. This type of link is called a switching fabric interface. Its purpose is to
carry Layer 2 traffic between nodes.

• Configuring a LAG with family ethernet-switching is not supported.

• Configuring a Reth with family ethernet-switching is not supported. This is only supported in
Transparent mode.

• If a switching fabric interface (swfab) is not configured on both nodes, and if you try to configure
Ethernet switching related features on the nodes, then the behavior of the nodes might be
unpredictable.

Understanding Chassis Cluster Failover and New Primary Election

When chassis cluster failover occurs, a new primary node is elected and the Ethernet switching process
(eswd) runs in a different node. During failover, the chassis control subsystem is restarted. Also during
failover, traffic outage occurs until the PICs are up and the VLAN entries are reprogrammed. After
failover, all Layer 2 protocols reconverge because Layer 2 protocol states are not maintained in the
secondary node.

The Q-in-Q feature in chassis cluster mode is not supported because of chip limitation for swfab
interface configuration in Broadcom chipsets.
456

Benefits of Ethernet Switching on Chassis Cluster

• Enables Ethernet switching functionality on both nodes of a chassis cluster and provides the option
to configure the Ethernet ports on either node for family Ethernet switching.

• Enables configuring a Layer 2 VLAN domain with member ports from both nodes and the Layer 2
switching protocols on both devices.

SEE ALSO

Ethernet Switching and Layer 2 Transparent Mode Overview


Understanding Mixed Mode (Transparent and Route Mode) on Security Devices

Example: Configuring Switch Fabric Interfaces to Enable Switching in


Chassis Cluster Mode on a Security Device

IN THIS SECTION

Requirements | 456

Overview | 457

Configuration | 457

This example shows how to configure switching fabric interfaces to enable switching in chassis cluster
mode.

Requirements
• The physical link used as the switch fabric member must be directly connected to the device.

• Switching fabric interfaces must be configured on ports that support switching features. See Ethernet
Ports Switching Overview for Security Devices for information about the ports on which switching
features are supported.

The physical link used as the switch fabric member must be directly connected to the device. Switching
supported ports must be used for switching fabric interfaces. See Ethernet Ports Switching Overview for
Security Devices for switching supported ports.
457

Before you begin, See "Example: Configuring the Chassis Cluster Fabric Interfaces" on page 60.

Overview
In this example, pseudointerfaces swfab0 and swfab1 are created for Layer 2 fabric functionality. You
also configure dedicated Ethernet ports on each node to be associated with the swfab interfaces.

Configuration

IN THIS SECTION

Verification | 458

Procedure

CLI Quick Configuration

To quickly configure this section of the example, copy the following commands, paste them into a text
file, remove any line breaks, change any details necessary to match your network configuration, copy
and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from
configuration mode.

set interfaces swfab0 fabric-options member-interfaces ge-0/0/3


set interfaces swfab1 fabric-options member-interfaces ge-9/0/3

Step-by-Step Procedure

To configure swfab interfaces:

1. Configure swfab0 and swfab1 and associate these switch fabric interfaces to enable switching across
the nodes. Note that swfab0 corresponds to node 0 and swfab1 corresponds to node 1.

{primary:node0} [edit]
user@host# set interfaces swfab0 fabric-options member-interfaces ge-0/0/3
user@host# set interfaces swfab1 fabric-options member-interfaces ge-9/0/3
458

2. If you are done configuring the device, commit the configuration.

{primary:node0} [edit]
user@host# commit

Results

From configuration mode, confirm your configuration by entering the show interfaces swfab0 command. If
the output does not display the intended configuration, repeat the configuration instructions in this
example to correct the configuration.

[edit]
user@host# show interfaces swfab0
fabric-options{
member-interfaces {
ge-0/0/3;
}
}

Verification

IN THIS SECTION

Verifying Switching Fabric Ports | 458

To confirm that the configuration is working properly, perform these tasks:

Verifying Switching Fabric Ports

Purpose

Verify that you are able to configure multiple ports as members of switching fabric ports.
459

Action

From configuration mode, enter the show interfaces swfab0 command to view the configured interfaces
for each port.

user@host# show interfaces swfab0


fabric-options{
member-interfaces {
ge-0/0/3;
}
}

From operational mode, enter the show chassis cluster ethernet-switching interfaces command to view the
appropriate member interfaces.

user@host> show chassis cluster ethernet-switching interfaces


swfab0:

Name Status
ge-0/0/3 up
swfab1:

Name Status
ge-9/0/3 up

SEE ALSO

SRX Series Chassis Cluster Configuration Overview | 13


460

Example: Configure IRB and VLAN with Members Across Two Nodes on a
Security Device using Tagged

IN THIS SECTION

Requirements | 460

Overview | 460

Configuration | 461

NOTE: Our content testing team has validated and updated this example.

Requirements
This example uses the following hardware and software components:

• configure a switching fabric interface on both nodes to configure Ethernet switching-related features
on the nodes. See "Example: Configuring Switch Fabric Interfaces to Enable Switching in Chassis
Cluster Mode on a Security Device" on page 456

• SRX550 security device

• interface-mode is supported in 15.1X49 release.

• port-mode is supported in 12.1 and 12.3X48 releases.

Overview

IN THIS SECTION

Topology | 461

This example shows the configuration of a VLAN with members across node 0 and node 1.
461

Topology

Figure 48 on page 461 shows the Layer 2 Ethernet switching across chassis cluster nodes using tagged
traffic.

Figure 48: Layer 2 Ethernet Switching Across Chassis Cluster using Tagged Traffic

Configuration

IN THIS SECTION

Verification | 466

Procedure

CLI Quick Configuration

To quickly configure this section of the example, copy the following commands, paste them into a text
file, remove any line breaks, change any details necessary to match your network configuration, copy
and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from
configuration mode.

set security zones security-zone trust host-inbound-traffic system-services all


set security zones security-zone trust interfaces irb.100
set security zones security-zone trust interfaces irb.200
set interfaces ge-0/0/4 unit 0 family ethernet-switching interface-mode trunk
462

set interfaces ge-0/0/4 unit 0 family ethernet-switching vlan members v100


set interfaces ge-0/0/5 unit 0 family ethernet-switching interface-mode trunk
set interfaces ge-0/0/5 unit 0 family ethernet-switching vlan members v200
set interfaces ge-9/0/4 unit 0 family ethernet-switching interface-mode trunk
set interfaces ge-9/0/4 unit 0 family ethernet-switching vlan members v100
set interfaces ge-9/0/5 unit 0 family ethernet-switching interface-mode trunk
set interfaces ge-9/0/5 unit 0 family ethernet-switching vlan members v200
set interfaces fab0 fabric-options member-interfaces ge-0/0/2
set interfaces fab1 fabric-options member-interfaces ge-9/0/2
set interfaces irb unit 100 family inet address 10.1.100.254/24
set interfaces irb unit 200 family inet address 10.1.200.254/24
set interfaces swfab0 fabric-options member-interfaces ge-0/0/3
set interfaces swfab1 fabric-options member-interfaces ge-9/0/3
set vlans v100 vlan-id 100
set vlans v100 l3-interface irb.100
set vlans v200 vlan-id 200
set vlans v200 l3-interface irb.200

Step-by-Step Procedure

To configure IRB and a VLAN:

1. Configure security zones.

{primary:node0} [edit security zones]


user@host# set security-zone trust host-inbound-traffic system-services all
user@host# set security-zone trust interfaces irb.100
user@host# set security-zone trust interfaces irb.200

2. Configure Ethernet switching on the node0 interfaces.

{primary:node0} [edit interfaces]


user@host# set ge-0/0/4 unit 0 family ethernet-switching interface-mode trunk
user@host# set ge-0/0/4 unit 0 family ethernet-switching vlan members v100
user@host# set ge-0/0/5 unit 0 family ethernet-switching interface-mode trunk
user@host# set ge-0/0/5 unit 0 family ethernet-switching vlan members v200
user@host# set ge-9/0/4 unit 0 family ethernet-switching interface-mode trunk
user@host# set ge-9/0/4 unit 0 family ethernet-switching vlan members v100
user@host# set ge-9/0/5 unit 0 family ethernet-switching interface-mode trunk
user@host# set ge-9/0/5 unit 0 family ethernet-switching vlan members v200
463

3. Define the interfaces used for the fab connection (data plane links for RTOsync) by using physical
ports from each node. These interfaces must be connected back-to-back, or through a Layer 2
infrastructure.

{primary:node0} [edit interfaces]


user@host# set fab0 fabric-options member-interfaces ge-0/0/2
user@host# set fab1 fabric-options member-interfaces ge-9/0/2

4. configure a switching fabric interface on both nodes to configure Ethernet switching-related features
on the nodes.

{primary:node0} [edit interfaces]


user@host# set swfab0 fabric-options member-interfaces ge-0/0/3
user@host# set swfab1 fabric-options member-interfaces ge-9/0/3

5. Configure the irb interface.

{primary:node0} [edit interfaces]


user@host# set irb unit 100 family inet address 10.1.100.254/24
user@host# set irb unit 200 family inet address 10.1.200.254/24

6. Create and associate a VLAN interface with the VLAN.

{primary:node0} [edit vlans]


user@host# set v100 vlan-id 100
user@host# set v100 l3-interface irb.100
user@host# set v200 vlan-id 200
user@host# set v200 l3-interface irb.200

7. If you are done configuring the device, commit the configuration.

[edit]
user@host# commit
464

Results

From configuration mode, confirm your configuration by entering the show security, show interfaces, and
show vlans commands. If the output does not display the intended configuration, repeat the configuration
instructions in this example to correct the configuration.

[edit]
user@host# show security
zones {
security-zone trust {
host-inbound-traffic {
system-services {
all;
}
}
interfaces {
irb.100;
irb.200;
}
}
}

[edit]
user@host# show interfaces
ge-0/0/4 {
unit 0 {
family ethernet-switching {
interface-mode trunk;
vlan {
members v100;
}
}
}
}
ge-0/0/5 {
unit 0 {
family ethernet-switching {
interface-mode trunk;
vlan {
members v200;
}
465

}
}
}
ge-9/0/4 {
unit 0 {
family ethernet-switching {
interface-mode trunk;
vlan {
members v100;
}
}
}
}
ge-9/0/5 {
unit 0 {
family ethernet-switching {
interface-mode trunk;
vlan {
members v200;
}
}
}
}
fab0 {
fabric-options {
member-interfaces {
ge-0/0/2;
}
}
}
fab1 {
fabric-options {
member-interfaces {
ge-9/0/2;
}
}
}
irb {
unit 100 {
family inet {
address 10.1.100.254/24;
}
}
466

unit 200 {
family inet {
address 10.1.200.254/24;
}
}
}
swfab0 {
fabric-options {
member-interfaces {
ge-0/0/3;
}
}
}
swfab1 {
fabric-options {
member-interfaces {
ge-9/0/3;
}
}
}

[edit]
user@host# show vlans
v100 {
vlan-id 100;
l3-interface irb.100;
}
v200 {
vlan-id 200;
l3-interface irb.200;
}

Verification

IN THIS SECTION

Verifying Tagged VLAN With IRB | 467


467

Verifying Tagged VLAN With IRB

Purpose

Verify that the configuration for tagged VLAN with IRB is working properly.

Action

From operational mode, enter the show chassis cluster interfaces command.

user@host> show chassis cluster interfaces


Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 fxp1 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 ge-0/0/2 Up / Up Enabled
fab0
fab1 ge-9/0/2 Up / Up Enabled
fab1

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

From operational mode, enter the show ethernet-switching table command.

user@host> show ethernet-switching table


MAC flags (S - static MAC, D - dynamic MAC, L - locally learned, P - Persistent static, C -
Control MAC
SE - statistics enabled, NM - non configured MAC, R - remote PE MAC, O - ovsdb MAC)

Ethernet switching table : 4 entries, 4 learned


Routing instance : default-switch
468

Vlan MAC MAC Age Logical NH


RTR
name address flags interface Index
ID
v100 08:81:f4:8a:eb:52 D - ge-9/0/4.0 0
0
v100 08:81:f4:8a:eb:54 D - ge-0/0/4.0 0
0
v200 08:81:f4:8a:eb:53 D - ge-9/0/5.0 0
0
v200 08:81:f4:8a:eb:55 D - ge-0/0/5.0 0 0

From operational mode, enter the show arp command.

user@host> show arp


MAC Address Address Name Interface Flags
08:81:f4:8a:eb:54 10.1.100.1 10.1.100.1 irb.100 none
08:81:f4:8a:eb:52 10.1.100.2 10.1.100.2 irb.100 none
08:81:f4:8a:eb:55 10.1.200.1 10.1.200.1 irb.200 none
08:81:f4:8a:eb:53 10.1.200.2 10.1.200.2 irb.200 none
ec:3e:f7:c6:81:b0 30.17.0.2 30.17.0.2 fab0.0 permanent
f0:4b:3a:09:cb:30 30.18.0.1 30.18.0.1 fab1.0 permanent
ec:3e:f7:c6:80:81 130.16.0.1 130.16.0.1 fxp1.0 none
Total entries: 7

From operational mode, enter the show ethernet-switching interface command to view the information
about Ethernet switching interfaces.

user@host> show ethernet-switching interface


Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
SCTL - shutdown by Storm-control, MI - MAC+IP limit hit)

Logical Vlan TAG MAC MAC+IP STP Logical Tagging


interface members limit limit state interface flags
ge-0/0/5.0 16383 8192 tagged
v200 200 1024 1024 Forwarding tagged
Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
469

LH - MAC limit hit, DN - interface down,


MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
SCTL - shutdown by Storm-control, MI - MAC+IP limit hit)

Logical Vlan TAG MAC MAC+IP STP Logical Tagging


interface members limit limit state interface flags
ge-0/0/4.0 16383 8192 tagged
v100 100 1024 1024 Forwarding tagged
Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
SCTL - shutdown by Storm-control, MI - MAC+IP limit hit)

Logical Vlan TAG MAC MAC+IP STP Logical Tagging


interface members limit limit state interface flags
ge-9/0/4.0 16383 8192 tagged
v100 100 1024 1024 Forwarding tagged
Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
SCTL - shutdown by Storm-control, MI - MAC+IP limit hit)

Logical Vlan TAG MAC MAC+IP STP Logical Tagging


interface members limit limit state interface flags
ge-9/0/5.0 16383 8192 tagged
v200 200 1024 1024 Forwarding tagged

Meaning

The output shows the VLANs are configured and working fine.
470

Example: Configure IRB and VLAN with Members Across Two Nodes on a
Security Device using Untagged Traffic

IN THIS SECTION

Requirements | 470

Overview | 470

Configuration | 471

NOTE: Our content testing team has validated and updated this example.

Requirements
This example uses the following hardware and software components:

• configure a switching fabric interface on both nodes to configure Ethernet switching-related features
on the nodes. See "Example: Configuring Switch Fabric Interfaces to Enable Switching in Chassis
Cluster Mode on a Security Device" on page 456

• SRX550 security device

• interface-mode is supported in 15.1X49 release.

• port-mode is supported in 12.1 and 12.3X48 releases.

Overview

IN THIS SECTION

Topology | 471

This example shows the configuration of a VLAN with members across node 0 and node 1.
471

Topology

Figure 49 on page 471 shows the Layer 2 Ethernet switching across chassis cluster nodes using
untagged traffic.

Figure 49: Layer2 Ethernet Switching Across Chassis Cluster Nodes using Untagged Traffic

Configuration

IN THIS SECTION

Verification | 476

Procedure

CLI Quick Configuration

To quickly configure this section of the example, copy the following commands, paste them into a text
file, remove any line breaks, change any details necessary to match your network configuration, copy
and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from
configuration mode.

set security zones security-zone trust host-inbound-traffic system-services all


set security zones security-zone trust interfaces irb.100
set security zones security-zone trust interfaces irb.200
set interfaces ge-0/0/4 unit 0 family ethernet-switching interface-mode access
472

set interfaces ge-0/0/4 unit 0 family ethernet-switching vlan members v100


set interfaces ge-0/0/5 unit 0 family ethernet-switching interface-mode access
set interfaces ge-0/0/5 unit 0 family ethernet-switching vlan members v200
set interfaces ge-9/0/4 unit 0 family ethernet-switching interface-mode access
set interfaces ge-9/0/4 unit 0 family ethernet-switching vlan members v100
set interfaces ge-9/0/5 unit 0 family ethernet-switching interface-mode access
set interfaces ge-9/0/5 unit 0 family ethernet-switching vlan members v200
set interfaces fab0 fabric-options member-interfaces ge-0/0/2
set interfaces fab1 fabric-options member-interfaces ge-9/0/2
set interfaces irb unit 100 family inet address 10.1.100.254/24
set interfaces irb unit 200 family inet address 10.1.200.254/24
set interfaces swfab0 fabric-options member-interfaces ge-0/0/3
set interfaces swfab1 fabric-options member-interfaces ge-9/0/3
set vlans v100 vlan-id 100
set vlans v100 l3-interface irb.100
set vlans v200 vlan-id 200
set vlans v200 l3-interface irb.200

Step-by-Step Procedure

To configure IRB and a VLAN:

1. Configure security zones.

{primary:node0} [edit security zones]


user@host# set security-zone trust host-inbound-traffic system-services all
user@host# set security-zone trust interfaces irb.100
user@host# set security-zone trust interfaces irb.200

2. Configure Ethernet switching on the node0 interfaces.

{primary:node0} [edit interfaces]


user@host# set ge-0/0/4 unit 0 family ethernet-switching interface-mode access
user@host# set ge-0/0/4 unit 0 family ethernet-switching vlan members v100
user@host# set ge-0/0/5 unit 0 family ethernet-switching interface-mode access
user@host# set ge-0/0/5 unit 0 family ethernet-switching vlan members v200
user@host# set ge-9/0/4 unit 0 family ethernet-switching interface-mode access
user@host# set ge-9/0/4 unit 0 family ethernet-switching vlan members v100
user@host# set ge-9/0/5 unit 0 family ethernet-switching interface-mode access
user@host# set ge-9/0/5 unit 0 family ethernet-switching vlan members v200
473

3. Define the interfaces used for the fab connections (data plane links for RTOsync) by using physical
ports from each node. These interfaces must be connected back-to-back, or through a Layer 2
infrastructure.

{primary:node0} [edit interfaces]


user@host# set fab0 fabric-options member-interfaces ge-0/0/2
user@host# set fab1 fabric-options member-interfaces ge-9/0/2

4. configure a switching fabric interface on both nodes to configure Ethernet switching-related features
on the nodes.

{primary:node0} [edit interfaces]


user@host# set swfab0 fabric-options member-interfaces ge-0/0/3
user@host# set swfab1 fabric-options member-interfaces ge-9/0/3

5. Configure the irb interface.

{primary:node0} [edit interfaces]


user@host# set irb unit 100 family inet address 10.1.100.254/24
user@host# set irb unit 200 family inet address 10.1.200.254/24

6. Create and associate a VLAN interface with the VLAN.

{primary:node0} [edit vlans]


user@host# set v100 vlan-id 100
user@host# set v100 l3-interface irb.100
user@host# set v200 vlan-id 200
user@host# set v200 l3-interface irb.200

7. If you are done configuring the device, commit the configuration.

[edit]
user@host# commit
474

Results

From configuration mode, confirm your configuration by entering the show security, show interfaces, and
show vlans commands. If the output does not display the intended configuration, repeat the configuration
instructions in this example to correct the configuration.

[edit]
user@host# show security
zones {
security-zone trust {
host-inbound-traffic {
system-services {
all;
}
}
interfaces {
irb.100;
irb.200;
}
}
}

[edit]
user@host# show interfaces
ge-0/0/4 {
unit 0 {
family ethernet-switching {
interface-mode access;
vlan {
members v100;
}
}
}
}
ge-0/0/5 {
unit 0 {
family ethernet-switching {
interface-mode access;
vlan {
members v200;
}
475

}
}
}
ge-9/0/4 {
unit 0 {
family ethernet-switching {
interface-mode access;
vlan {
members v100;
}
}
}
}
ge-9/0/5 {
unit 0 {
family ethernet-switching {
interface-mode access;
vlan {
members v200;
}
}
}
}
fab0 {
fabric-options {
member-interfaces {
ge-0/0/2;
}
}
}
fab1 {
fabric-options {
member-interfaces {
ge-9/0/2;
}
}
}
irb {
unit 100 {
family inet {
address 10.1.100.254/24;
}
}
476

unit 200 {
family inet {
address 10.1.200.254/24;
}
}
}
swfab0 {
fabric-options {
member-interfaces {
ge-0/0/3;
}
}
}
swfab1 {
fabric-options {
member-interfaces {
ge-9/0/3;
}
}
}

[edit]
user@host# show vlans
v100 {
vlan-id 100;
l3-interface irb.100;
}
v200 {
vlan-id 200;
l3-interface irb.200;
}

Verification

IN THIS SECTION

Verifying Untagged VLAN With IRB | 477


477

Verifying Untagged VLAN With IRB

Purpose

Verify that the configuration of untagged VLAN with IRB is working properly.

Action

From operational mode, enter the show chassis cluster interfaces command.

user@host> show chassis cluster interfaces


Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 fxp1 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 ge-0/0/2 Up / Up Enabled
fab0
fab1 ge-9/0/2 Up / Up Enabled
fab1

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

From operational mode, enter the show ethernet-switching table command.

user@host> show ethernet-switching table


MAC flags (S - static MAC, D - dynamic MAC, L - locally learned, P - Persistent static, C -
Control MAC
SE - statistics enabled, NM - non configured MAC, R - remote PE MAC, O - ovsdb MAC)

Ethernet switching table : 4 entries, 4 learned


Routing instance : default-switch
478

Vlan MAC MAC Age Logical NH


RTR
name address flags interface Index
ID
v100 08:81:f4:8a:eb:52 D - ge-9/0/4.0 0
0
v100 08:81:f4:8a:eb:54 D - ge-0/0/4.0 0
0
v200 08:81:f4:8a:eb:53 D - ge-9/0/5.0 0
0
v200 08:81:f4:8a:eb:55 D - ge-0/0/5.0 0 0

From operational mode, enter the show arp command.

user@host> show arp


MAC Address Address Name Interface Flags
08:81:f4:8a:eb:54 10.1.100.1 10.1.100.1 irb.100 none
08:81:f4:8a:eb:52 10.1.100.2 10.1.100.2 irb.100 none
08:81:f4:8a:eb:55 10.1.200.1 10.1.200.1 irb.200 none
08:81:f4:8a:eb:53 10.1.200.2 10.1.200.2 irb.200 none
ec:3e:f7:c6:81:b0 30.17.0.2 30.17.0.2 fab0.0 permanent
f0:4b:3a:09:cb:30 30.18.0.1 30.18.0.1 fab1.0 permanent
ec:3e:f7:c6:80:81 130.16.0.1 130.16.0.1 fxp1.0 none
Total entries: 7

From operational mode, enter the show ethernet-switching interface command to view the information
about Ethernet switching interfaces.

user@host> show ethernet-switching interface


Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
SCTL - shutdown by Storm-control, MI - MAC+IP limit hit)

Logical Vlan TAG MAC MAC+IP STP Logical Tagging


interface members limit limit state interface flags
ge-0/0/5.0 16383 8192 untagged
v200 200 1024 1024 Forwarding untagged
Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
479

LH - MAC limit hit, DN - interface down,


MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
SCTL - shutdown by Storm-control, MI - MAC+IP limit hit)

Logical Vlan TAG MAC MAC+IP STP Logical Tagging


interface members limit limit state interface flags
ge-0/0/4.0 16383 8192 untagged
v100 100 1024 1024 Forwarding untagged
Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
SCTL - shutdown by Storm-control, MI - MAC+IP limit hit)

Logical Vlan TAG MAC MAC+IP STP Logical Tagging


interface members limit limit state interface flags
ge-9/0/4.0 16383 8192 untagged
v100 100 1024 1024 Forwarding untagged
Routing Instance Name : default-switch
Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
SCTL - shutdown by Storm-control, MI - MAC+IP limit hit)

Logical Vlan TAG MAC MAC+IP STP Logical Tagging


interface members limit limit state interface flags
ge-9/0/5.0 16383 8192 untagged
v200 200 1024 1024 Forwarding untagged

Meaning

The output shows the VLANs are configured and working fine.
480

Example: Configuring VLAN with Members Across Two Nodes on a


Security Device

IN THIS SECTION

Requirements | 480

Overview | 480

Configuration | 480

Verification | 483

Requirements
This example uses the following hardware and software components:

• configure a switching fabric interface on both nodes to configure Ethernet switching-related features
on the nodes. See "Example: Configuring Switch Fabric Interfaces to Enable Switching in Chassis
Cluster Mode on a Security Device" on page 456

• SRX240 security device

• Junos OS 12.3X48-D90

• interface-mode is supported in 15.1X49 release.

• port-mode is supported in 12.1 and 12.3X48 releases.

Overview
This example shows the configuration of a VLAN with members across node 0 and node 1.

Configuration

IN THIS SECTION

Procedure | 481
481

Procedure

CLI Quick Configuration

To quickly configure this section of the example, copy the following commands, paste them into a text
file, remove any line breaks, change any details necessary to match your network configuration, copy
and paste the commands into the CLI at the [edit] hierarchy level, and then enter commit from
configuration mode.

set interfaces ge-0/0/3 unit 0 family ethernet-switching port-mode access


set interfaces ge-0/0/3 unit 0 family ethernet-switching vlan members vlan100
set interfaces ge0/0/4 unit 0 family ethernrt-switching port-mode access
set interfaces ge-0/0/4 unit 0 family ethernet-switching vlan members vlan100
set interfaces ge-7/0/5 unit 0 family ethernet-switching port-mode trunk
set interfaces ge-7/0/5 unit 0 family ethernet-switching vlan members vlan100
set interfaces vlan unit 100 family inet address 11.1.1.1/24
set vlans vlan100 vlan-id 100
set vlans vlan100 l3-interface vlan.100

Step-by-Step Procedure

To configure VLAN:

1. Configure Ethernet switching on the node0 interface.

{primary:node0} [edit]
user@host# set interfaces ge-0/0/3 unit 0 family ethernet-switching port-mode access
user@host# set interfaces ge0/0/4 unit 0 family ethernet-switching port-mode access

2. Configure Ethernet switching on the node1 interface.

{primary:node0} [edit]
user@host# set interfaces ge-7/0/5 unit 0 family ethernet-switching port-mode trunk

3. Create VLAN vlan100 with vlan-id 100.

{primary:node0} [edit]
user@host# set vlans vlan100 vlan-id 100
482

4. Add interfaces from both nodes to the VLAN.

{primary:node0} [edit]
user@host# set interfaces ge-0/0/3 unit 0 family ethernet-switching vlan members vlan100
user@host# set interfaces ge-0/0/4 unit 0 family ethernet-switching vlan members vlan100
user@host# set interfaces ge-7/0/5 unit 0 family ethernet-switching vlan members vlan100

5. Create a VLAN interface.

user@host# set interfaces vlan unit 100 family inet address 11.1.1.1/24

6. Associate an VLAN interface with the VLAN.

user@host# set vlans vlan100 l3-interface vlan.100

7. If you are done configuring the device, commit the configuration.

[edit]
user@host# commit

Results

From configuration mode, confirm your configuration by entering the show vlans and show interfaces
commands. If the output does not display the intended configuration, repeat the configuration
instructions in this example to correct the configuration.

[edit]
user@host# show vlans
vlan100 {
vlan-id 100;
l3-interface vlan.100;
}
[edit]
user@host# show interfaces
ge-0/0/3 {
unit 0 {
family ethernet-switching {
port-mode access;
483

vlan {
members vlan100;
}
}
}
}
ge-0/0/4 {
unit 0 {
family ethernet-switching {
port-mode access;
vlan {
members vlan100;
}
}
}
}
ge-7/0/5 {
unit 0 {
family ethernet-switching {
port-mode trunk;
vlan {
members vlan100;
}
}
}
}

Verification

IN THIS SECTION

Verifying VLAN | 483

Verifying VLAN

Purpose

Verify that the configuration of VLAN is working properly.


484

Action

From operational mode, enter the show interfaces terse ge-0/0/3 command to view the node 0 interface.

user@host> show interfaces terse ge-0/0/3


Interface Admin Link Proto Local Remote
ge-0/0/3 up up
ge-0/0/3.0 up up eth-switch

From operational mode, enter the show interfaces terse ge-0/0/4 command to view the node 0 interface.

user@host> show interfaces terse ge-0/0/4


Interface Admin Link Proto Local Remote
ge-0/0/4 up up
ge-0/0/4.0 up up eth-switch

From operational mode, enter the show interfaces terse ge-7/0/5 command to view the node1 interface.

user@host> show interfaces terse ge-7/0/5


Interface Admin Link Proto Local Remote
ge-7/0/5 up up
ge-7/0/5.0 up up eth-switch

From operational mode, enter the show vlans command to view the VLAN interface.

user@host> show vlans


Routing instance VLAN name Tag Interfaces
default-switch default 1
default-switch vlan100 100 ge-0/0/3.0*
ge-0/0/4.0*
ge-7/0/5.0*

From operational mode, enter the show ethernet-switching interface command to view the information
about Ethernet switching interfaces.

Routing Instance Name : default-switch


Logical Interface flags (DL - disable learning, AD - packet action drop,
LH - MAC limit hit, DN - interface down,
MMAS - Mac-move action shutdown, AS - Autostate-exclude enabled,
485

SCTL - shutdown by Storm-control )

Logical Vlan TAG MAC STP Logical Tagging


interface members limit state interface flags
ge-0/0/3.0 16383 DN untagged
vlan100 100 1024 Discarding untagged
ge-0/0/4.0 16383 DN untagged
vlan100 100 1024 Discarding untagged
ge-7/0/5.0 16383 DN tagged
vlan100 100 1024 Discarding tagged

Meaning

The output shows the VLANs are configured and working fine.

SEE ALSO

Example: Configuring an IRB Interface

RELATED DOCUMENTATION

Configuring Chassis Clustering on SRX Series Devices | 129

Media Access Control Security (MACsec) on Chassis


Cluster

IN THIS SECTION

Understanding Media Access Control Security (MACsec) | 486

Configuring Media Access Control Security (MACsec) | 489


486

Media Access Control Security (MACsec) is an industry-standard security technology that provides
secure communication for all traffic on Ethernet links. for more information, see the following topics:

Understanding Media Access Control Security (MACsec)

IN THIS SECTION

How MACsec Works | 487

Understanding Connectivity Associations and Secure Channels | 487

Understanding Static Connectivity Association Key Security Mode | 487

MACsec Considerations | 488

Media Access Control Security (MACsec) is an industry-standard security technology that provides
secure communication for all traffic on Ethernet links. MACsec provides point-to-point security on
Ethernet links between directly connected nodes and is capable of identifying and preventing most
security threats, including denial of service, intrusion, man-in-the-middle, masquerading, passive
wiretapping, and playback attacks.

MACsec allows you to secure an Ethernet link for almost all traffic, including frames from the Link Layer
Discovery Protocol (LLDP), Link Aggregation Control Protocol (LACP), Dynamic Host Configuration
Protocol (DHCP), Address Resolution Protocol (ARP), and other protocols that are not typically secured
on an Ethernet link because of limitations with other security solutions. MACsec can be used in
combination with other security protocols such as IP Security (IPsec) and Secure Sockets Layer (SSL) to
provide end-to-end network security.

Starting in Junos OS Release 15.1X49-D60, Media Access Control Security(MACsec) is supported on


control and fabric ports of SRX340 and SRX345 devices in chassis cluster mode.

Starting in Junos OS Release 20.1R1, MACsec is supported on control ports, fabric ports and revenue
ports of SRX380 devices in chassis cluster mode to secure the traffic. MACsec is supported on
16X1Gigabit Ethernet ports (ge-0/0/0 to ge-0/0/15) and 4X10Gigabit Ethernet ports (xe-0/0/16 to
xe-0/0/19).

Starting in Junos OS Release 17.4R1, MACsec is supported on HA control and fabric ports of SRX4600
devices in chassis cluster mode.

This topic contains the following sections:


487

How MACsec Works

To determine if a feature is supported by a specific platform or Junos OS release, refer Feature Explorer.

MACsec provides industry-standard security through the use of secured point-to-point Ethernet links.
The point-to-point links are secured after matching security keys. When you enable MACsec using static
connectivity association key (CAK) security mode, user-configured pre-shared keys are exchanged and
verified between the interfaces at each end of the point-to-point Ethernet link.

Once MACsec is enabled on a point-to-point Ethernet link, all traffic traversing the link is MACsec-
secured through the use of data integrity checks and, if configured, encryption.

The data integrity checks verify the integrity of the data. MACsec appends an 8-byte header and a 16-
byte tail to all Ethernet frames traversing the MACsec-secured point-to-point Ethernet link, and the
header and tail are checked by the receiving interface to ensure that the data was not compromised
while traversing the link. If the data integrity check detects anything irregular about the traffic, the
traffic is dropped.

MACsec can also be used to encrypt all traffic on the Ethernet link. The encryption used by MACsec
ensures that the data in the Ethernet frame cannot be viewed by anybody monitoring traffic on the link.

Encryption is enabled for all traffic entering or leaving the interface when MACsec is enabled using
static CAK security mode, by default.

MACsec is configured on point-to-point Ethernet links between MACsec-capable interfaces. If you want
to enable MACsec on multiple Ethernet links, you must configure MACsec individually on each point-to-
point Ethernet link.

Understanding Connectivity Associations and Secure Channels

MACsec is configured in connectivity associations. MACsec is enabled when a connectivity association


is assigned to an interface.

When you enable MACsec using static CAK or dynamic security mode, you have to create and configure
a connectivity association. Two secure channels—one secure channel for inbound traffic and another
secure channel for outbound traffic—are automatically created. The automatically-created secure
channels do not have any user-configurable parameters; all configuration is done in the connectivity
association outside of the secure channels.

Understanding Static Connectivity Association Key Security Mode

When you enable MACsec using static connectivity association key (CAK) security mode, two security
keys—a connectivity association key (CAK) that secures control plane traffic and a randomly-generated
secure association key (SAK) that secures data plane traffic—are used to secure the point-to-point
488

Ethernet link. Both keys are regularly exchanged between both devices on each end of the point-to-
point Ethernet link to ensure link security.

You initially establish a MACsec-secured link using a pre-shared key when you are using static CAK
security mode to enable MACsec. A pre-shared key includes a connectivity association name (CKN) and
it’s own connectivity association key (CAK). The CKN and CAK are configured by the user in the
connectivity association and must match on both ends of the link to initially enable MACsec.

Once matching pre-shared keys are successfully exchanged, the MACsec Key Agreement (MKA)
protocol is enabled. The MKA protocol is responsible for maintaining MACsec on the link, and decides
which switch on the point-to-point link becomes the key server. The key server then creates an SAK that
is shared with the switch at the other end of the point-to-point link only, and that SAK is used to secure
all data traffic traversing the link. The key server will continue to periodically create and share a
randomly-created SAK over the point-to-point link for as long as MACsec is enabled.

You enable MACsec using static CAK security mode by configuring a connectivity association on both
ends of the link. All configuration is done within the connectivity association but outside of the secure
channel. Two secure channels—one for inbound traffic and one for outbound traffic—are automatically
created when using static CAK security mode. The automatically-created secure channels do not have
any user-configurable parameters that cannot already be configured in the connectivity association.

We recommend enabling MACsec using static CAK security mode. Static CAK security mode ensures
security by frequently refreshing to a new random security key and by only sharing the security key
between the two devices on the MACsec-secured point-to-point link. Additionally, some optional
MACsec features—replay protection, SCI tagging, and the ability to exclude traffic from MACsec—are
only available when you enable MACsec using static CAK security mode.

Starting with Junos OS Release 15.1X49-D60 and Junos OS Release 17.3R1, for SRX Series Firewalls
supporting MACsec on HA control and fabric links, if the command restart 802.1x-protocol-daemon is run on
the primary node, the chassis cluster control and fabric links will flap causing the cluster nodes to enter
into split brain mode.

MACsec Considerations

All types of Spanning Tree Protocol frames cannot currently be encrypted using MACsec.

The connectivity association can be defined anywhere, either global or node specific or any other
configuration group as long as it is visible to the MACsec interface configuration.

For MACsec configurations, identical configurations must exist on both the ends. That is, each node
should contain the same configuration as the other node. If the other node is not configured or
improperly configured with MACsec on the other side, the port is disabled and stops forwarding the
traffic.

SRX340, SRX345, and SRX380 devices support MACsec for host-to-host or switch-to-host connections.
489

SRX4600 devices currently do not support MACsec for host-to-host connections. Macsec is supported
only on dedicated fab ports and is not supported if any ther traffic port is used as fab.

On SRX340, SRX345, and SRX380 devices, fabric interfaces must be configured such that the Media
Access Control Security (MACsec) configurations are local to the nodes. Otherwise, the fabric link will
not be reachable

Configuring Media Access Control Security (MACsec)

IN THIS SECTION

Configuration Considerations When Configuring MACsec on Chassis Cluster Setup | 489

Configuring MACsec Using Static Connectivity Association Key Security Mode | 491

Configuring Static CAK on the Chassis Cluster Control Port | 496

Configuring Static CAK on the Chassis Cluster Fabric Port | 497

Configuring Static CAK on the Control Port of SRX4600 Device in Chassis Cluster | 498

Verifying MACSEC Configuration | 499

Starting in Junos OS Release 15.1X49-D60, Media Access Control Security(MACsec) is supported on


control and fabric ports of SRX340 and SRX345 devices in chassis cluster mode.

Starting in Junos OS Release 17.4R1, MACsec is supported on control and fabric ports of SRX4600
devices in chassis cluster mode.

This topic shows how to configure MACsec on control and fabric ports of supported SRX Series Firewall
in chassis cluster to secure point-to-point Ethernet links between the peer devices in a cluster. Each
point-to-point Ethernet link that you want to secure using MACsec must be configured independently.
You can enable MACsec encryption on device-to-device links using static connectivity association key
(CAK) security mode.

The configuration steps for both processes are provided in this document.

Configuration Considerations When Configuring MACsec on Chassis Cluster Setup


Before you begin, follow these steps to configure MACsec on control ports:

1. If the chassis cluster is already up, disable it by using the set chassis cluster disable command and
reboot both nodes.
490

2. Configure MACsec on the control port with its attributes as described in the following sections
"Configuring Static CAK on the Chassis Cluster Control Port" on page 496. Both nodes must be
configured independently with identical configurations.
3. Enable the chassis cluster by using set chassis cluster cluster-id id on both of the nodes. Reboot both
nodes.

Control port states affect the integrity of a chassis cluster. Consider the following when configuring
MACsec on control ports:

• Any new MACsec chassis cluster port configurations or modifications to existing MACsec chassis
cluster port configurations will require the chassis cluster to be disabled and displays a warning
message Modifying cluster control port CA will break chassis cluster. Once disabled, you can apply the
preceding configurations and enable the chassis cluster.

• By default, chassis clusters synchronize all configurations. Correspondingly, you must monitor that
synchronization does not lead to loss of any MACsec configurations. Otherwise, the chassis cluster
will break. For example, for nonsymmetric, node-specific MACsec configurations, identical
configurations should exist on both ends. That is, each node should contain the same configuration
as the other node.

The ineligible timer is 300 seconds when MACsec on the chassis cluster control port is enabled on
SRX340, SRX345, and SRX380 devices.

If both control link fail, Junos OS changes the operating state of the secondary node to ineligible for a
180 seconds. When MACsec is enabled on the control port, the ineligibility duration is 200 seconds for
SRX4600 devices.

Starting with Junos OS Release 15.1X49-D60 and Junos OS Release 17.3R1, the initial hold timer is
extended from 30 seconds to 120 seconds in chassis clusters on SRX340, SRX345, and SRX380 devices.

For any change in the MACsec configurations of control ports, the steps mentioned above must be
repeated.

Consider the following when configuring MACsec on fabric ports:

Configuring MACsec leads to link state changes that can affect traffic capability of the link. When you
configure fabric ports, keep the effective link state in mind. Incorrect MACsec configuration on both
ends of the fabric links can move the link to an ineligible state. Note the following key points about
configuring fabric links:

• Both ends of the links must be configured simultaneously when the chassis cluster is formed.

• Incorrect configuration can lead to fabric failures and errors in fabric recovery logic.

Because of potential link failure scenarios, we recommend that fabric links be configured during
formation of the chassis cluster.
491

Configuring MACsec Using Static Connectivity Association Key Security Mode


You can enable MACsec encryption by using static connectivity association key (CAK) security mode on
a point-to-point Ethernet link connecting devices. This procedure shows you how to configure MACsec
using static CAK security mode.

For SRX340 and SRX345 devices, ge-0/0/0 is a fabric port and ge-0/0/1 is a control port for the chassis
cluster and assigned as cluster-control-port 0.

For configuring MACsec on cluster-control-port and cluster-data-port on SRX380 devices, the node
must be in standalone node. The MACsec configuration is applied on both the nodes and the nodes are
rebooted to chassis cluster mode. For SRX380 devices, ge-0/0/0 is a fabric port and ge-0/0/15 is a
control port for the chassis cluster.

For SRX4600 devices, dedicated control and fabric ports are available. MACsec on control link can be
configured on dedicated control ports (control port 0 [em0] and port 1 [em1]). Macsec on fabric links can
be configured only on dedicated fabric ports port 2 and port 3 of fpc0 pic0 (e.g. xe-0/0/2 and xe-0/0/3),
similarly on port-2 and port-3 of fpc7 pic0.

To configure MACsec by using static CAK security mode to secure a device-to-device Ethernet link:

1. Create a connectivity association. You can skip this step if you are configuring an existing
connectivity association.

[edit security macsec]


user@host# set connectivity-association connectivity-association-name

For instance, to create a connectivity association named ca1, enter:

[edit security macsec]


user@host# set connectivity-association ca1

2. Configure the MACsec security mode as static-cak for the connectivity association.

[edit security macsec]


user@host# set connectivity-association connectivity-association-name security-mode static-
cak
492

For instance, to configure the MACsec security mode to static-cak on connectivity association ca1:

[edit security macsec]


user@host# set connectivity-association connectivity-association-name security-mode static-
cak

3. Create the preshared key by configuring the connectivity association key name (CKN) and
connectivity association key (CAK).

[edit security macsec]


user@host# set connectivity-association connectivity-association-name pre-shared-key ckn
hexadecimal-number
user@host# set connectivity-association connectivity-association-name pre-shared-key cak
hexadecimal-number

A preshared key is exchanged between directly-connected links to establish a MACsec-secure link.


The pre-shared-key includes the CKN and the CAK. The CKN is a 64-digit hexadecimal number and
the CAK is a 64-digit hexadecimal number. The CKN and the CAK must match on both ends of a
link to create a MACsec-secured link.

To maximize security, we recommend configuring all 64 digits of a CKN and all 64 digits of a CAK.

After the preshared keys are successfully exchanged and verified by both ends of the link, the
MACsec Key Agreement (MKA) protocol is enabled and manages the secure link. The MKA protocol
then elects one of the two directly-connected devices as the key server. The key server then shares
a random security with the other device over the MACsec-secure point-to-point link. The key
server will continue to periodically create and share a random security key with the other device
over the MACsec-secured point-to-point link as long as MACsec is enabled.

To configure a CKN of 11c1c1c11xxx012xx5xx8ef284aa23ff6729xx2e4xxx66e91fe34ba2cd9fe311 and CAK of


228xx255aa23xx6729xx664xxx66e91f on connectivity association ca1:

[edit security macsec]


user@host# set connectivity-association ca1 pre-shared-key ckn
11c1c1c11xxx012xx5xx8ef284aa23ff6729xx2e4xxx66e91fe34ba2cd9fe311
user@host# set connectivity-association ca1 pre-shared-key cak
228xx255aa23xx6729xx664xxx66e91f

MACsec is not enabled until a connectivity association is attached to an interface. See the final step
of this procedure to attach a connectivity association to an interface.
493

4. (Optional) Set the MKA key server priority.

[edit security macsec connectivity-association connectivity-association-name]


user@host# set mka key-server-priority priority-number

Specifies the key server priority used by the MKA protocol to select the key server. The device with
the lower priority-number is selected as the key server.

The default priority-number is 16.

If the key-server-priority is identical on both sides of the point-to-point link, the MKA protocol
selects the interface with the lower MAC address as the key server. Therefore, if this statement is
not configured in the connectivity associations at each end of a MACsec-secured point-to-point
link, the interface with the lower MAC address becomes the key server.

To change the key server priority to 0 to increase the likelihood that the current device is selected
as the key server when MACsec is enabled on the interface using connectivity association ca1:

[edit security macsec connectivity-association ca1]


user@host# set mka key-server-priority 0

To change the key server priority to 255 to decrease the likelihood that the current device is
selected as the key server in connectivity association ca1:

[edit security macsec connectivity-association ca1]


user@host# set mka key-server-priority 255

5. (Optional) Set the MKA transmit interval.

[edit security macsec connectivity-association connectivity-association-name]


user@host# set mka transmit-interval interval

The MKA transmit interval setting sets the frequency for how often the MKA protocol data unit
(PDU) is sent to the directly connected device to maintain MACsec connectivity on the link. A
lower interval increases bandwidth overhead on the link; a higher interval optimizes MKA protocol
communication.

The default interval is 2000 ms. We recommend increasing the interval to 6000 ms in high-traffic
load environments. The transmit interval settings must be identical on both ends of the link when
MACsec using static CAK security mode is enabled.
494

Starting from Junos OS Release 17.4, for SRX340, SRX345, and SRX4600, the default MKA
transmit interval is 10000 ms on HA links.

For SRX380 devices, the default MKA transmit interval is 2000 milliseconds.

For instance, if you wanted to increase the MKA transmit interval to 6000 milliseconds when
connectivity association ca1 is attached to an interface:

[edit security macsec connectivity-association ca1]


user@host# set mka transmit-interval 6000

6. (Optional) Disable MACsec encryption.

[edit security macsec connectivity-association connectivity-association-name]


user@host# set no-encryption

Encryption is enabled for all traffic entering or leaving the interface when MACsec is enabled using
static CAK security mode, by default.

When encryption is disabled, traffic is forwarded across the Ethernet link in clear text. You are able
to view unencrypted data in the Ethernet frame traversing the link when you are monitoring it. The
MACsec header is still applied to the frame, however, and all MACsec data integrity checks are run
on both ends of the link to ensure the traffic sent or received on the link has not been tampered
with and does not represent a security threat.
7. (Optional) Set an offset for all packets traversing the link.

[edit security macsec connectivity-association connectivity-association-name]


user@host# set offset (0 | 30 | 50)

For instance, if you wanted to set the offset to 30 in the connectivity association named ca1:

[edit security macsec connectivity-association ca1]


user@host# set offset 30

The default offset is 0. All traffic in the connectivity association is encrypted when encryption is
enabled and an offset is not set.

When the offset is set to 30, the IPv4 header and the TCP/UDP header are unencrypted while
encrypting the rest of the traffic. When the offset is set to 50, the IPv6 header and the TCP/UDP
header are unencrypted while encrypting the rest of the traffic.
495

You would typically forward traffic with the first 30 or 50 octets unencrypted if a feature needed to
see the data in the octets to perform a function, but you otherwise prefer to encrypt the remaining
data in the frames traversing the link. Load balancing features, in particular, typically need to see
the IP and TCP/UDP headers in the first 30 or 50 octets to properly load balance traffic.
8. (Optional) Enable replay protection.

[edit security macsec connectivity-association connectivity-association-name]


user@host# set replay-protect replay-window-size number-of-packets

When MACsec is enabled on a link, an ID number is assigned to each packet on the MACsec-
secured link.

When replay protection is enabled, the receiving interface checks the ID number of all packets that
have traversed the MACsec-secured link. If a packet arrives out of sequence and the difference
between the packet numbers exceeds the replay protection window size, the packet is dropped by
the receiving interface. For instance, if the replay protection window size is set to five and a packet
assigned the ID of 1006 arrives on the receiving link immediately after the packet assigned the ID
of 1000, the packet that is assigned the ID of 1006 is dropped because it falls outside the
parameters of the replay protection window.

Replay protection is especially useful for fighting man-in-the-middle attacks. A packet that is
replayed by a man-in-the-middle attacker on the Ethernet link will arrive on the receiving link out of
sequence, so replay protection helps ensure the replayed packet is dropped instead of forwarded
through the network.

Replay protection should not be enabled in cases where packets are expected to arrive out of order.

You can require that all packets arrive in order by setting the replay window size to 0.

To enable replay protection with a window size of five on connectivity association ca1:

[edit security macsec connectivity-association ca1]


user@host# set replay-protect replay-window-size 5

9. (Optional) Exclude a protocol from MACsec.

[edit security macsec connectivity-association connectivity-association-name]


user@host# set exclude-protocol protocol-name
496

For instance, if you did not want Link Level Discovery Protocol (LLDP) to be secured using MACsec:

[edit security macsec connectivity-association connectivity-association-name]


user@host# set exclude-protocol lldp

When this option is enabled, MACsec is disabled for all packets of the specified protocol—in this
case, LLDP—that are sent or received on the link.
10. Assign the connectivity association to a chassis cluster control interface.

[edit security macsec]


user@host# set cluster-control-port port-no connectivity-association connectivity-
association-name

Assigning the connectivity association to an interface is the final configuration step for enabling
MACsec on an interface.

For instance, to assign connectivity association ca1 to interface ge-0/0/1 (For SRX340/SRX345):

For instance, to assign connectivity association ca1 to interface ge-0/0/0 (For SRX380):

[edit security macsec]


user@host# set cluster-control-port interfaces ge-0/0/1 connectivity-association ca1

11. Assign a connectivity association for enabling MACsec on a chassis cluster fabric interface.

[edit security macsec]


user@host# set cluster-data-port port-number connectivity-association connectivity-
association-name
[edit security macsec]
user@host# set cluster-data-port interfaces ge-5/0/2 connectivity-association ca1

MACsec using static CAK security mode is not enabled until a connectivity association on the opposite
end of the link is also configured, and contains preshared keys that match on both ends of the link.

Configuring Static CAK on the Chassis Cluster Control Port


To establish a CA over a chassis cluster control link on two SRX345 devices.
497

1. Configure the MACsec security mode as static-cak for the connectivity association:

[edit security macsec]


user@host# set connectivity-association ca1 security-mode static-cak

2. Create the preshared key by configuring the connectivity association key name (CKN).

[edit security macsec]


user@host# set connectivity-association ca1 pre-shared-key ckn
0123456789abcdefABCDEF0123456789

The CKN must be an even-length string up to 64 hexadecimal characters (0-9, a-f, A-F).
3. Create the pre-shared key by configuring the connectivity association key (CAK).

[edit security macsec]


user@host# set connectivity-association ca1 pre-shared-key cak
0123456789abcdefABCDEF0123456789

The CAK must contain 64 hexadecimal characters (0-9, a-f, A-F).


4. Specify chassis cluster control ports for the connectivity association.

[edit security macsec]


user@host# set cluster-control-port 0 connectivity-association ca1

Configuring Static CAK on the Chassis Cluster Fabric Port


To establish a connectivity association over a chassis cluster fabric link on two SRX345 devices:

1. Configure the MACsec security mode as static-cak for the connectivity association.

[edit security macsec]


user@host# set connectivity-association ca2 security-mode static-cak

2. Create the preshared key by configuring the connectivity association key name (CKN).

[edit security macsec]


user@host# set connectivity-association ca2 pre-shared-key ckn
0123456789abcdefABCDEF0123456789
498

The CKN must be an even-length string up to 64 hexadecimal characters (0-9, a-f, A-F).
3. Create the preshared key by configuring the connectivity association key (CAK).

[edit security macsec]


user@host# set connectivity-association ca2 pre-shared-key cak
0123456789abcdefABCDEFabcdefabcdef

The CAK must contain 64 hexadecimal characters (0-9, a-f, A-F).


4. Specify a chassis cluster fabric ports to a connectivity association.

[edit security macsec]


user@host# set cluster-data-port ge-0/0/2 connectivity-association ca2
user@host# set cluster-data-port ge-5/0/2 connectivity-association ca2

Configuring Static CAK on the Control Port of SRX4600 Device in Chassis Cluster
Use this procedure to establish a CA over a chassis cluster control link on two SRX4600 devices.

1. Configure the MACsec security mode as static-cak for the connectivity association:

[edit]
user@host# set security macsec connectivity-association ca1 security-mode static-cak

2. Create the preshared key by configuring the connectivity association key name (CKN).

[edit]
user@host# set security macsec connectivity-association ca1 pre-shared-key ckn
aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa

The CKN must be an even-length string up to 64 hexadecimal characters (0-9, a-f, A-F).
3. Create the preshared key by configuring the connectivity association key (CAK).

[edit]
user@host# set security macsec connectivity-association ca1 pre-shared-key cak
ABCDEFABCDEFABCDEFABCDEFABCDEFABCDEFABCDEFABCDEF.

The CAK must contain 64 hexadecimal characters (0-9, a-f, A-F).


499

4. Specify a chassis cluster control port for the connectivity association.

[edit]
user@host# set security macsec cluster-control-port 0 connectivity-association ca1
user@host# set security macsec cluster-control-port 1 connectivity-association ca1

Verifying MACSEC Configuration

IN THIS SECTION

Display the Status of Active MACsec Connections on the Device | 499

Display MACsec Key Agreement (MKA) Session Information | 500

Verifying That MACsec-Secured Traffic Is Traversing Through the Interface | 501

Verifying Chassis Cluster Ports Are Secured with MACsec Configuration | 503

To confirm that the configuration provided in "Configuring Static CAK on the Control Port of SRX4600
Device in Chassis Cluster" on page 498 is working properly, perform these tasks:

Display the Status of Active MACsec Connections on the Device

IN THIS SECTION

Purpose | 499

Action | 500

Meaning | 500

Purpose

Verify that MACsec is operational on the chassis cluster setup.


500

Action

From the operational mode, enter the show security macsec connections interface interface-name command on
one or both of the nodes of chassis cluster setup.

{primary:node0}[edit]
user@host# show security macsec connections

Interface name: em0


CA name: ca1
Cipher suite: GCM-AES-128 Encryption: on
Key server offset: 0 Include SCI: no
Replay protect: off Replay window: 0
Outbound secure channels
SC Id: 02:00:00:01:01:04/1
Outgoing packet number: 1
Secure associations
AN: 3 Status: inuse Create time: 00:01:43
Inbound secure channels
SC Id: 02:00:00:02:01:04/1
Secure associations
AN: 3 Status: inuse Create time: 00:01:43

Meaning

The Interface name and CA name outputs show that the MACsec connectivity association is operational on
the interface em0. The output does not appear when the connectivity association is not operational on
the interface.

Display MACsec Key Agreement (MKA) Session Information

IN THIS SECTION

Purpose | 501

Action | 501

Meaning | 501
501

Purpose

Display MACsec Key Agreement (MKA) session information for all interfaces.

Action

From the operational mode, enter the show security mka sessions command.

user@host> show security mka sessions

Interface name: em0


Member identifier: B51CXXXX2678A7F5F6C12345
CAK name: AAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAAA
Transmit interval: 10000(ms)
Outbound SCI: 02:00:00:01:01:04/1
Message number: 270 Key number: 8
Key server: yes Key server priority: 16
Latest SAK AN: 3 Latest SAK KI: B51C8XXX2678A7A5B6C54321/8
Previous SAK AN: 0 Previous SAK KI: 000000000000000000000000/0
Peer list
1. Member identifier: 0413427B38817XXXXF054321 (live)
Message number: 8 Hold time: 59000 (ms)
SCI: 02:00:00:02:01:04/1
Lowest acceptable PN: 0

Meaning

The outputs show the status of MKA sessions.

Verifying That MACsec-Secured Traffic Is Traversing Through the Interface

IN THIS SECTION

Purpose | 502

Action | 502

Meaning | 502
502

Purpose

Verify that traffic traversing through the interface is MACsec-secured.

Action

From the operational mode, enter the show security macsec statistics command.

user@host> show security macsec statistics interface em0 detail

Interface name: em0


Secure Channel transmitted
Encrypted packets: 2397305
Encrypted bytes: 129922480
Protected packets: 0
Protected bytes: 0
Secure Association transmitted
Encrypted packets: 2397305
Protected packets: 0
Secure Channel received
Accepted packets: 2395850
Validated bytes: 0
Decrypted bytes: 131715088
Secure Association received
Accepted packets: 2395850
Validated bytes: 0
Decrypted bytes: 0

Meaning

The Encrypted packets line under the Secure Channel transmitted field are the values incremented each time a
packet is sent from the interface that is secured and encrypted by MACsec.

The Accepted packets line under the Secure Association received field are the values incremented each time a
packet that has passed the MACsec integrity check is received on the interface. The Decrypted bytes line
under the Secure Association received output is incremented each time an encrypted packet is received and
decrypted.
503

Verifying Chassis Cluster Ports Are Secured with MACsec Configuration

IN THIS SECTION

Purpose | 503

Action | 503

Meaning | 504

Purpose

Verify that MACsec is configured on chassis cluster ports.

Action

From operational mode, enter the show chassis cluster interfaces command.

user@host> show chassis cluster interfaces

Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Up Disabled Enabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-1/1/6 Up / Up Enabled
fab0
fab1 xe-8/1/6 Up / Up Enabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
504

reth1 Up 2
reth2 Down Not configured
reth3 Down Not configured
reth4 Down Not configured
reth5 Down Not configured
reth6 Down Not configured
reth7 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Meaning

The Security line under the Control interfaces output for em0 interface shown as Secured means that the
traffic sent from the em0 interface is secured and encrypted by MACsec.

You can also use the show chassis cluster status command to display the current status of the chassis
cluster.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


macsec | 656

Release History Table

Release Description

17.4R1 Starting in Junos OS Release 17.4R1, MACsec is supported on HA control and fabric ports of
SRX4600 devices in chassis cluster mode.

15.1X49-D60 Starting in Junos OS Release 15.1X49-D60, Media Access Control Security(MACsec) is supported
on control and fabric ports of SRX340 and SRX345 devices in chassis cluster mode.

RELATED DOCUMENTATION

SRX Series Chassis Cluster Configuration Overview | 13


Understanding SRX Series Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming | 18
505

macsec | 656

Understanding SCTP Behavior in Chassis Cluster

In a chassis cluster configuration mode, the SCTP configuration and the established SCTP association is
synced with the peer device. The SCTP module supports both active-active and active-passive modes.

The established SCTP association sends a creation or deletion message to the peer whenever an
association is created or deleted on the active device. The secondary device adds or deletes an
association respectively upon receiving the message from the established SCTP association. SCTP
module then registers the corresponding callback function to receive and handle this message. There is
no continuous timer sync between the two associations.

SCTP module will register a cold start sync function when a secondary device joins the cluster or
reboots. The SCTP cold start function is called to sync all SCTP associations with the peer devices at the
same time.

After the switchover, the established SCTP associations will remain functioning, but the associations in
the progress of establishment will be lost and the establishment procedure needs to be re-initiated. It is
also possible that the associations in the progress of teardown miss the ack message and leaves
unestablished SCTP associations in the firewall. These associations will be cleaned up when the timer
expires (5 hours by default) due to no activity in the association.

• You should configure all policies for your required SCTP sessions.
For example, suppose you have endpoints A and B. Endpoint A has one SCTP association with x
number of IPs (IP_a1, IP_a2, IP_a3...IP_ax). Endpoint B has one SCTP association with y number of
IPs (IP_b1, IP_b2, IP_b3...IP_by.) The policy on the security device should permit all possible x*y paths
in both directions.

• When an SCTP association is removed, the related SCTP sessions still exist and time out by
themselves.

Example: Encrypting Messages Between Two Nodes


in a Chassis Cluster

This example provides you a procedure to enable encryption on security devices.


506

This procedure provides you step on how you can optionally configure the control-link to encrypt
messages between two nodes in a chassis cluster. This configuration will ensure secure login by using
configured internal IPsec security association (SA).

When the internal IPsec SA is configured, IPsec-based rlogin and remote command (rcmd) are enforced
so that attackers cannot gain privileged access or observe traffic containing administrator commands
and outputs.

You do not need to configure the internal IPsec SA on both nodes because the nodes are synchronized
when the configuration is committed.

1. To enable control link encryption in chassis cluster, run the following commands:
The only supported encryption algorithm is 3des-cbc and the key must be exactly 24 bytes long,
otherwise the configuration will result in commit failure.

edit security ipsec internal security-association


root@srx-8# show | display set
set security ipsec internal security-association manual encryption algorithm 3des-cbc
set security ipsec internal security-association manual encryption ike-ha-link-encryption
enable
set security ipsec internal security-association manual encryption key ascii-text "$9$8gPx-
b4aU.PQs2PQFnpu8X7dsgGUHPT3.Pu1EhvMwYgJjq3n9CpBFntOREeKZGDj.fu01hcr"

2. Commit the configuration.

{primary:node0} [edit] root@srx-8# commit


warning: changes needs reboot to take effect

warning: changes needs reboot to take effect


node0: commit complete
node1: commit complete

After the settings have been configured correctly and committed, a reboot would be required for the
feature to take effect.
507

3. View the configuration of control link encryption before reboot and after reboot.

Before reboot, the status of this feature is disabled.


show security internal-security-association

node0:
--------------------------------------------------------------------------
Internal SA Status : Disabled
HA link encryption for IKE internal message status: Disabled

node1:
--------------------------------------------------------------------------
Internal SA Status : Disabled
HA link encryption for IKE internal message status: Disabled

After reboot, to ensure that the encryption is active


show security internal-security-association

{primary:node0}
root@srx-8> show security internal-security-association

node0:
--------------------------------------------------------------------------
Internal SA Status : Enabled
HA link encryption for IKE internal message status: Enabled

node1:
--------------------------------------------------------------------------
Internal SA Status : Enabled
HA link encryption for IKE internal message status: Enabled

RELATED DOCUMENTATION

internal (Security IPsec)


5 CHAPTER

Upgrading or Disabling a Chassis


Cluster

Upgrading Individual Devices in a Chassis Cluster Separately | 509

Upgrading Devices in a Chassis Cluster Using ICU | 509

Upgrading a Chassis Cluster Using In-Service Software Upgrade | 514

Disabling a Chassis Cluster | 536


509

Upgrading Individual Devices in a Chassis Cluster


Separately

Devices in a chassis cluster can be upgraded separately one at a time; some models allow one device
after the other to be upgraded using failover and an in-service software upgrade (ISSU) to reduce the
operational impact of the upgrade.

To upgrade each device in a chassis cluster separately:

During this type of chassis cluster upgrade, a service disruption of about 3 to 5 minutes occurs.

1. Load the new image file on node 0.


2. Perform the image upgrade without rebooting the node by entering:

user@host> request system software add image_name

3. Load the new image file on node 1.


4. Repeat Step 2.
5. Reboot both nodes simultaneously.

RELATED DOCUMENTATION

Upgrading Devices in a Chassis Cluster Using ICU | 509


Upgrading a Chassis Cluster Using In-Service Software Upgrade | 514

Upgrading Devices in a Chassis Cluster Using ICU

IN THIS SECTION

Upgrading Both Devices in a Chassis Cluster Using ICU | 510

Upgrading ICU Using a Build Available Locally on a Primary Node in a Chassis Cluster | 511

Upgrading ICU Using a Build Available on an FTP Server | 512

Terminating an Upgrade in a Chassis Cluster During an ICU | 513


510

The chassis cluster ICU method allows both devices in a cluster to be upgraded from supported Junos
OS versions using a single command. For more information, see the following topics:

NOTE: For SRX300, SRX320, SRX340, SRX345, and SRX380 Firewalls, if you are upgrading to
Junos OS Release 23.2R1, you cannot use the ICU method. You must use either the procedures
outlined in KB 72737 (upgrade) or the minimal downtime procedure documented in KB17947
(Minimal_Downtime_Upgrade_Branch_Mid PDF file). Once you have upgraded to Junos OS
Release 23.2R1, you can use the ICU method to upgrade to any later releases or downgrade from
one of those later releases to Junos OS Release 23.2R1 or later.

Upgrading Both Devices in a Chassis Cluster Using ICU

Before you begin, note the following:

• ICU is available with the no-sync option only for SRX300, SRX320, SRX340, SRX345, SRX550M, and
SRX380 devices.

• Before starting ICU, you should ensure that sufficient disk space is available. See "Upgrading ICU
Using a Build Available Locally on a Primary Node in a Chassis Cluster" on page 511 and "Upgrading
ICU Using a Build Available on an FTP Server" on page 512.

• For SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX380 devices, this feature cannot be used
to downgrade to a build earlier than Junos OS 11.2 R2.

For SRX1500 devices, this feature cannot be used to downgrade to a build earlier than Junos OS
15.1X49-D50.

SRX Series Firewalls in a chassis cluster can be upgraded with a minimal service disruption using In-Band
Cluster Upgrade (ICU). The chassis cluster ICU feature allows both devices in a cluster to be upgraded
from supported Junos OS versions using a single command. You can enable this feature by executing the
request system software in-service-upgrade image_name command on the primary node. This command
upgrades the Junos OS and reboots both the secondary node and the primary node in turn. During the
ICU process, traffic outage is minimal; however, cold synchronization is not provided between the two
nodes.

For SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX380 devices, the devices in a chassis cluster
can be upgraded with a minimal service disruption of approximately 30 seconds using ICU with the no-
sync option. The chassis cluster ICU feature allows both devices in a cluster to be upgraded from
supported Junos OS versions.
511

You must use the in-band cluster upgrade (ICU) commands on SRX1500 device to upgrade following
Junos OS Releases:

• Junos OS Release 15.1X49-D50 to Junos OS Release 15.1X49-D100

• Junos OS Release 15.1X49-D60 to Junos OS Release 15.1X49-D110

• Junos OS Release 15.1X49-D50 to Junos OS Release 15.1X49-D120

For SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX380 devices, the impact on traffic is as
follows:

• Drop in traffic (30 seconds approximately)

• Loss of security flow sessions

The upgrade is initiated with the Junos OS build locally available on the primary node of the device or
on an FTP server.

• The primary node, RG0, changes to the secondary node after an ICU upgrade.

• During ICU, the chassis cluster redundancy groups are failed over to the primary node to change the
cluster to active/passive mode.

• ICU states can be checked from the syslog or with the console/terminal logs.

• ICU requires that both nodes be running a dual-root partitioning scheme with one exception being
the SRX1500. ICU will not continue if it fails to detect dual-root partitioning on either of the nodes.
Requirement of the dual-root partitioning is applicable only for SRX300, SRX320, SRX340, SRX345,
SRX550M, and SRX380 devices.

Dual-root partitioning is not supported on SRX1500 devices. SRX1500 uses solid-state drive (SSD) as
secondary storage.

Upgrading ICU Using a Build Available Locally on a Primary Node in a


Chassis Cluster

Ensure that sufficient disk space is available for the Junos OS package in the /var/tmp location in the
secondary node of the cluster.

To upgrade ICU using a build locally available on the primary node of a cluster:

1. Copy the Junos OS package build to the primary node at any location, or mount a network file server
folder containing the Junos OS build.
512

2. Start ICU by entering the following command:


user@host> request system software in-service-upgrade image_name no-sync (for SRX300, SRX320, SRX340,
SRX345, SRX550M, and SRX380 devices)

user@host> request system software in-service-upgrade image_name (for SRX1500 devices prior to Junos OS
Release 15.1X49-D70)

Upgrading ICU Using a Build Available on an FTP Server

Ensure that sufficient disk space is available for the Junos OS package in the /var/tmp location in both
the primary and the secondary nodes of the cluster.

To upgrade ICU using a build available on an FTP server:

1. Place the Junos OS build on an FTP server.


2. (SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX380 only) Start ICU by entering the
following command:
user@root> request system software in-service-upgrade <ftp url for junos image> no-sync

Sample Command

user@root> request system software in-service-upgrade ftp://<user>:<password>@<server>:/


<path> no-sync

This command upgrades the Junos OS and reboots both nodes in turn.
3. (SRX1500 only prior to Junos OS Release 15.1X49-D70) Start ICU by entering the following
command:
user@root> request system software in-service-upgrade <ftp url for junos image>

Sample Command

user@root> request system software in-service-upgrade ftp://<user>:<password>@<server>:/<path>

This command upgrades the Junos OS and reboots both nodes in turn.

The upgrade process displays the following warning message to reboot the system:

WARNING: A reboot is required to load this software correctly. Use the request system reboot command
when software installation is complete.

This warning message can be ignored because the ICU process automatically reboots both the nodes.
513

Terminating an Upgrade in a Chassis Cluster During an ICU

You can terminate an ICU at any time by issuing the following command on the primary node:

request system software abort in-service-upgrade

Issuing an abort command during or after the secondary node reboots puts the cluster in an inconsistent
state. The secondary node boots up running the new Junos OS build, while the primary continues to run
the older Junos OS build.

To recover from the chassis cluster inconsistent state, perform the following actions sequentially on the
secondary node:

1. Issue an abort command:


request system software abort in-service-upgrade
2. Roll back the Junos OS build by entering the following command:
request system software rollback node < node-id >
3. Reboot the secondary node immediately by using the following command:
request system reboot

You must execute the above steps sequentially to complete the recovery process and avoid cluster
instability.

Table 35 on page 513 lists the options and their descriptions for the request system software in-service-
upgrade command.

Table 35: request system software in-service-upgrade Output Fields

Options Description

no-sync Disables the flow state from syncing up when the old secondary node has booted with a new
Junos OS image.

This option is not available on SRX1500 devices.

no-tcp-syn-check Creates a window wherein the TCP SYN check for the incoming packets will be disabled. The
default value for the window is 7200 seconds (2 hours).

This option is not available on SRX1500 devices.

no-validate Disables the validation of the configuration at the time of the installation. The system
behavior is similar to software add.
514

Table 35: request system software in-service-upgrade Output Fields (Continued)

Options Description

unlink Removes the package from the local media after installation.

• During ICU, if a termination command is executed, ICU will terminate only after the current
operation finishes. This is required to avoid any inconsistency with the devices.

For example, if formatting and upgrade of a node is in progress, ICU terminates after this operation
finishes.

• After a termination, ICU will try to roll back the build on the nodes if the upgrading nodes step was
completed.

RELATED DOCUMENTATION

Upgrading Individual Devices in a Chassis Cluster Separately | 509


Upgrading a Chassis Cluster Using In-Service Software Upgrade | 514
Disabling a Chassis Cluster | 536

Upgrading a Chassis Cluster Using In-Service


Software Upgrade

IN THIS SECTION

Understanding ISSU for a Chassis Cluster | 515

ISSU System Requirements | 518

Upgrading Both Devices in a Chassis Cluster Using ISSU | 519

Rolling Back Devices in a Chassis Cluster After an ISSU | 521

Enabling an Automatic Chassis Cluster Node Failback After an ISSU | 522

Log Error Messages used for Troubleshooting ISSU-Related Problems | 522

Managing Chassis Cluster ISSU-Related Problems | 531


515

In-service software upgrade (ISSU) enables a software upgrade from one Junos OS version to a later
Junos OS version with minimal downtime. For more information, see the following topics:

Understanding ISSU for a Chassis Cluster

In-service software upgrade (ISSU) enables a software upgrade from one Junos OS version to a later
Junos OS version with little or no downtime. ISSU is performed when the devices are operating in
chassis cluster mode only.

The chassis cluster ISSU feature enables both devices in a cluster to be upgraded from supported Junos
OS versions with a minimal disruption in traffic and without a disruption in service.

Starting with Junos OS Release 15.1X49-D80, SRX4100 and SRX4200 devices support ISSU.

Starting with Junos OS Release 15.1X49-D70, SRX1500 devices support ISSU.

• On SRX1500, SRX4100, and SRX4200 devices, ISSU is not supported for upgrading to 17.4 releases
from previous Junos OS releases. ISSU is supported for upgrading from Junos OS 17.4 to successive
17.4 releases.

• On SRX5400, SRX5600 and SRX5800 devices, ISSU is not supported for upgrading to 17.3 and
higher releases from earlier Junos OS releases. ISSU is supported for upgrading from Junos OS 17.3
to Junos 17.4 releases.

• SRX300 Series devices, SRX550M devices and vSRX Virtual Firewall do not support ISSU.

You can use the in-band cluster upgrade (ICU) commands on SRX4100 and SRX4200 devices to upgrade
following Junos OS Releases:

• Junos OS Release 15.1X49-D65 to Junos OS Release 15.1X49-D70

• Junos OS Release 15.1X49-D70 to Junos OS Release 15.1X49-D80.

You must use the in-band cluster upgrade (ICU) commands on SRX1500 device to upgrade following
Junos OS Releases:

• Junos OS Release 15.1X49-D50 to Junos OS Release 15.1X49-D60

• Junos OS Release 15.1X49-D60 to Junos OS Release 15.1X49-D70

• Junos OS Release 15.1X49-D50 to Junos OS Release 15.1X49-D70

ISSU provides the following benefits:

• Eliminates network downtime during software image upgrades


516

• Reduces operating costs, while delivering higher service levels

• Allows fast implementation of new features

ISSU has the following limitations:

• ISSU is available only for Junos OS Release 10.4R4 or later.

• ISSU does not support software downgrades.

• If you upgrade from a Junos OS version that supports only IPv4 to a version that supports both IPv4
and IPv6, the IPv4 traffic continue to work during the upgrade process. If you upgrade from a Junos
OS version that supports both IPv4 and IPv6 to a version that supports both IPv4 and IPv6, both the
IPv4 and IPv6 traffic continue to work during the upgrade process. Junos OS Release 10.2 and later
releases support flow-based processing for IPv6 traffic.

• During an ISSU, you cannot bring any PICs online. You cannot perform operations such as commit,
restart, or halt.

• During an ISSU, operations like fabric monitoring, control link recovery, and RGX preempt are
suspended.

• During an ISSU, you cannot commit any configurations.

For details about ISSU support status, see knowledge base article KB17946.

The following process occurs during an ISSU for devices in a chassis cluster. The sequences given below
are applicable when RG-0 is node 0 (primary node). Note that you must initiate an ISSU from RG-0
primary. If you initiate the upgrade on node 1 (RG-0 secondary), an error message is displayed.

1. At the beginning of a chassis cluster ISSU, the system automatically fails over all RG-1+ redundancy
groups that are not primary on the node from which the ISSU is initiated. This action ensures that
all the redundancy groups are active on only the RG-0 primary node.

The automatic failover of all RG-1+ redundancy groups is available from Junos OS release 12.1 or
later. If you are using Junos OS release 11.4 or earlier, before starting the ISSU, ensure that all the
redundancy groups are all active on only the RG-0 primary node.

After the system fails over all RG-1+ redundancy groups, it sets the manual failover bit and changes
all RG-1+ primary node priorities to 255, regardless of whether the redundancy group failed over to
the RG-0 primary node.

2. The primary node (node 0) validates the device configuration to ensure that it can be committed
using the new software version. Checks are made for disk space availability for the /var file system
on both nodes, unsupported configurations, and unsupported Physical Interface Cards (PICs).

If the disk space available on either of the Routing Engines is insufficient, the ISSU process fails and
returns an error message. However, unsupported PICs do not prevent the ISSU. The software issues
517

a warning to indicate that these PICs will restart during the upgrade. Similarly, an unsupported
protocol configuration does not prevent the ISSU. However, the software issues a warning that
packet loss might occur for the protocol during the upgrade.

3. When the validation succeeds, the kernel state synchronization daemon (ksyncd) synchronizes the
kernel on the secondary node (node 1) with the node 0.

4. Node 1 is upgraded with the new software image. Before being upgraded, the node 1 gets the
configuration file from node 0 and validates the configuration to ensure that it can be committed
using the new software version. After being upgraded, it is resynchronized with node 0.

5. The chassis cluster process (chassisd) on the node 0 prepares other software processes for the
lISSU. When all the processes are ready, chassisd sends a message to the PICs installed in the
device.

6. The Packet Forwarding Engine on each Flexible PIC Concentrator (FPC) saves its state and
downloads the new software image from node 1. Next, each Packet Forwarding Engine sends a
message (unified-ISSU ready) to the chassisd.

7. After receiving the message (unified-ISSU ready) from a Packet Forwarding Engine, the chassisd
sends a reboot message to the FPC on which the Packet Forwarding Engine resides. The FPC
reboots with the new software image. After the FPC is rebooted, the Packet Forwarding Engine
restores the FPC state and a high-speed internal link is established with node 1 running the new
software. The chassisd is also reestablished with node 0.

8. After all Packet Forwarding Engines have sent a ready message using the chassisd on node 0, other
software processes are prepared for a node switchover. The system is ready for a switchover at this
point.

9. Node switchover occurs and node 1 becomes the new primary node (hitherto secondary node 1).

10. The new secondary node (hitherto primary node 0) is now upgraded to the new software image.

When both nodes are successfully upgraded, the ISSU is complete.

When upgrading a version cluster that does not support encryption to a version that supports
encryption, upgrade the first node to the new version. Without the encryption configured and enabled,
two nodes with different versions can still communicate with each other and service is not broken. After
upgrading the first node, upgrade the second node to the new version. Users can decide whether to turn
on the encryption feature after completing the upgrade. Encryption must be deactivated before
downgrading to a version that does not support encryption. This ensures that communication between
an encryption-enabled version node and a downgraded node does not break, because both are no
longer encrypted.
518

ISSU System Requirements

You can use ISSU to upgrade from an ISSU-capable software release to a later release.

To perform an ISSU, your device must be running a Junos OS release that supports ISSU for the specific
platform. See Table 36 on page 518 for platform support.

Table 36: ISSU Platform Support

Device Junos OS Release

SRX5800 10.4R4 or later

SRX5600 10.4R4 or later

SRX5400 12.1X46-D20 or later

SRX1500 15.1X49-D70 or later

SRX4100 15.1X49-D80 or later

SRX4200 15.1X49-D80 or later

SRX4600 17.4R1 or later

For additional details on ISSU support and limitations, see ISSU/ICU Upgrade Limitations on SRX Series
Devices.

Note the following limitations related to an ISSU:

• The ISSU process is terminated if the Junos OS version specified for installation is a version earlier
than the one currently running on the device.

• The ISSU process is terminated if the specified upgrade conflicts with the current configuration, the
components supported, and so forth.

• ISSU does not support the extension application packages developed using the Junos OS SDK.

• ISSU does not support version downgrading on all supported SRX Series Firewalls.

• ISSU occasionally fails under heavy CPU load.


519

To downgrade from an ISSU-capable release to an earlier release (ISSU-capable or not), use the request
system software add command. Unlike an upgrade using the ISSU process, a downgrade using the request
system software add command might cause network disruptions and loss of data.

We strongly recommend that you perform ISSU under the following conditions:

• When both the primary and secondary nodes are healthy

• During system maintenance period

• During the lowest possible traffic period

• When the Routing Engine CPU usage is less than 40 percent

In cases where ISSU is not supported or recommended, while still downtime during the system upgrade
must be minimized, the minimal downtime procedure can be used, see knowledge base articleKB17947.

Upgrading Both Devices in a Chassis Cluster Using ISSU

Before you begin the ISSU for upgrading both the devices, note the following guidelines:

• Ensure the following ISSU pre-check requirements are met:

• All redundancy groups priority is greater than 0

• All redundancy groups are either primary or secondary in state

• There exists enough (double the image size) space available in the /var/tmp

• Usage of CPU is under 80% within 5 seconds period

If the pre-check requirements are not met, ISSU will terminate at the beginning.

• Back up the software using the request system snapshot command on each Routing Engine to back up
the system software to the device’s hard disk. The request system snapshot command is not supported
on SRX1500, SRX4100, SRX4200, and SRX4600 platforms.

• If you are using Junos OS Release 11.4 or earlier, before starting the ISSU, set the failover for all
redundancy groups so that they are all active on only one node (primary). See "Initiating a Chassis
Cluster Manual Redundancy Group Failover" on page 289.

If you are using Junos OS Release 12.1 or later, Junos OS automatically fails over all RGs to the RG0
primary.

• We recommend that you enable graceful restart for routing protocols before you start an ISSU.
520

On all supported SRX Series Firewalls, the first recommended ISSU from release is Junos OS Release
10.4R4.

The chassis cluster ISSU feature enables both devices in a cluster to be upgraded from supported Junos
OS versions with a traffic impact similar to that of redundancy group failovers.

Starting with Junos OS Release 15.1X49-D70, SRX1500 devices support ISSU.

Starting with Junos OS Release 15.1X49-D80, SRX4100 and SRX4200 devices support ISSU.

Starting with Junos OS Release 17.4R1, SRX4600 devices support ISSU.

To perform an ISSU from the CLI on Routing Engine2:

1. Download the software package from the Juniper Networks Support website: https://
www.juniper.net/support/downloads/
2. Copy the package on primary node of the cluster. We recommend that you copy the package to
the/var/tmp directory, which is a large file system on the hard disk. Note that the node from where
you initiate the ISSU must have the software image.
user@host>file copy ftp://username:[email protected]/filename /var/tmp/filename
3. Verify the current software version running on both nodes by issuing the show version command on
the primary node.
4. Start the ISSU from the node that is primary for all the redundancy groups by entering the following
command:

user@host> request system software in-service-upgrade image-name-with-full-path

For SRX1500, SRX4100, and SRX4200 devices, you can optionally remove the original image file by
including unlink in the command.

user@host> request system software in-service-upgrade image-name-with-full-path unlink

Wait for both nodes to complete the upgrade (After which you are logged out of the device).
5. Wait a few minutes, and then log in to the device again. Verify by using the show version command
that both devices in the cluster are running the new Junos OS release.
6. Verify that all policies, zones, redundancy groups, and other real-time objects (RTOs) return to their
correct states.
7. Make node 0 the primary node again by issuing the request chassis cluster failover node node-number
redundancy-group group-number command.

If you want redundancy groups to automatically return to node 0 as the primary after an in-service
software upgrade (ISSU), you must set the redundancy group priority such that node 0 is primary and
521

enable the preempt option. Note that this method works for all redundancy groups except redundancy
group 0. You must manually set the failover for redundancy group 0.

To set the redundancy group priority and enable the preempt option, see "Example: Configuring Chassis
Cluster Redundancy Groups" on page 95.

To manually set the failover for a redundancy group, see "Initiating a Chassis Cluster Manual
Redundancy Group Failover" on page 289.

During the upgrade, both devices might experience redundancy group failovers, but traffic is not
disrupted. Each device validates the package and checks version compatibility before beginning the
upgrade. If the system finds that the new package version is not compatible with the currently installed
version, the device refuses the upgrade or prompts you to take corrective action. Sometimes a single
feature is not compatible, in which case, the upgrade software prompts you to either terminate the
upgrade or turn off the feature before beginning the upgrade.

If you want to operate the SRX Series Firewall back as a standalone device or to remove a node from a
chassis cluster, ensure that you have terminated the ISSU procedure on both the nodes (in case ISSU
procedure is initiated)

To start ISSU process on Routing Engine3 for SRX 5K devices:

1. Run the following command to start ISSU:

user@host> request vmhost software in-service-upgrade image-name-with-full-path

SEE ALSO

In-Service Hardware Upgrade for SRX5K-RE-1800X4 and SRX5K-SCBE in a Chassis Cluster

Rolling Back Devices in a Chassis Cluster After an ISSU

If an ISSU fails to complete and only one device in the cluster is upgraded, you can roll back to the
previous configuration on the upgraded device alone by issuing one of the following commands on the
upgraded device:

• request chassis cluster in-service-upgrade abort

• request system software rollback node node-id reboot

• request system reboot


522

Enabling an Automatic Chassis Cluster Node Failback After an ISSU

If you want redundancy groups to automatically return to node 0 as the primary after the an in-service
software upgrade (ISSU), you must set the redundancy group priority such that node 0 is primary and
enable the preempt option. Note that this method works for all redundancy groups except redundancy
group 0. You must manually set the failover for a redundancy group 0. To set the redundancy group
priority and enable the preempt option, see "Example: Configuring Chassis Cluster Redundancy Groups"
on page 95. To manually set the failover for a redundancy group, see "Initiating a Chassis Cluster Manual
Redundancy Group Failover" on page 289.

To upgrade node 0 and make it available in the chassis cluster, manually reboot node 0. Node 0 does not
reboot automatically.

Log Error Messages used for Troubleshooting ISSU-Related Problems

IN THIS SECTION

Chassisd Process Errors | 522

Understanding Common Error Handling for ISSU | 523

ISSU Support-Related Errors | 527

Initial Validation Checks Failure | 527

Installation-Related Errors | 529

Redundancy Group Failover Errors | 530

Kernel State Synchronization Errors | 531

The following problems might occur during an ISSU upgrade. You can identify the errors by using the
details in the logs. For detailed information about specific system log messages, see System Log
Explorer.

Chassisd Process Errors

IN THIS SECTION

Problem | 523
523

Solution | 523

Problem

Description

Errors related to chassisd.

Solution

Use the error messages to understand the issues related to chassisd.

When ISSU starts, a request is sent to chassisd to check whether there are any problems related to the
ISSU from a chassis perspective. If there is a problem, a log message is created.

Understanding Common Error Handling for ISSU

IN THIS SECTION

Problem | 523

Solution | 523

Problem

Description

You might encounter some problems in the course of an ISSU. This section provides details on how to
handle them.

Solution

Any errors encountered during an ISSU result in the creation of log messages, and ISSU continues to
function without impact to traffic. If reverting to previous versions is required, the event is either logged
or the ISSU is halted, so as not to create any mismatched versions on both nodes of the chassis cluster.
Table 37 on page 524 provides some of the common error conditions and the workarounds for them.
524

The sample messages used in the Table 37 on page 524 are from the SRX1500 device and are also
applicable to all supported SRX Series Firewalls.

Table 37: ISSU-Related Errors and Solutions

Error Conditions Solutions

Attempt to initiate an The following message is displayed:


ISSU when previous
instance of an ISSU is warning: ISSU in progress
already in progress
You can abort the current ISSU process, and initiate the ISSU again using the request
chassis cluster in-service-upgrade abort command.

Reboot failure on the No service downtime occurs, because the primary node continues to provide required
secondary node services. Detailed console messages are displayed requesting that you manually clear
existing ISSU states and restore the chassis cluster.

error: [Oct 6 12:30:16]: Reboot secondary node failed (error-code: 4.1)

error: [Oct 6 12:30:16]: ISSU Aborted! Backup node maybe in inconsistent


state, Please restore backup node
[Oct 6 12:30:16]: ISSU aborted. But, both nodes are in ISSU window.
Please do the following:
1. Rollback the node with the newer image using rollback command
Note: use the 'node' option in the rollback command
otherwise, images on both nodes will be rolled back
2. Make sure that both nodes (will) have the same image
3. Ensure the node with older image is primary for all RGs
4. Abort ISSU on both nodes
5. Reboot the rolled back node

Starting with Junos OS Release 17.4R1, the hold timer for the initial reboot of the
secondary node during the ISSU process is extended from 15 minutes (900 seconds) to
45 minutes (2700 seconds) in chassis clusters on SRX1500, SRX4100, SRX4200, and
SRX4600 devices.
525

Table 37: ISSU-Related Errors and Solutions (Continued)

Error Conditions Solutions

Secondary node The primary node times out if the secondary node fails to complete the cold
failed to complete the synchronization. Detailed console messages are displayed that you manually clear
cold synchronization existing ISSU states and restore the chassis cluster. No service downtime occurs in this
scenario.

[Oct 3 14:00:46]: timeout waiting for secondary node node1 to sync(error-code: 6.1)
Chassis control process started, pid 36707

error: [Oct 3 14:00:46]: ISSU Aborted! Backup node has been upgraded, Please
restore backup node
[Oct 3 14:00:46]: ISSU aborted. But, both nodes are in ISSU window.
Please do the following:
1. Rollback the node with the newer image using rollback command
Note: use the 'node' option in the rollback command
otherwise, images on both nodes will be rolled back
2. Make sure that both nodes (will) have the same image
3. Ensure the node with older image is primary for all RGs
4. Abort ISSU on both nodes
5. Reboot the rolled back node
526

Table 37: ISSU-Related Errors and Solutions (Continued)

Error Conditions Solutions

Failover of newly No service downtime occurs, because the primary node continues to provide required
upgraded secondary services. Detailed console messages are displayed requesting that you manually clear
failed existing ISSU states and restore the chassis cluster.

[Aug 27 15:28:17]: Secondary node0 ready for failover.


[Aug 27 15:28:17]: Failing over all redundancy-groups to node0
ISSU: Preparing for Switchover
error: remote rg1 priority zero, abort failover.
[Aug 27 15:28:17]: failover all RGs to node node0 failed (error-code: 7.1)
error: [Aug 27 15:28:17]: ISSU Aborted!
[Aug 27 15:28:17]: ISSU aborted. But, both nodes are in ISSU window.
Please do the following:
1. Rollback the node with the newer image using rollback command
Note: use the 'node' option in the rollback command
otherwise, images on both nodes will be rolled back
2. Make sure that both nodes (will) have the same image
3. Ensure the node with older image is primary for all RGs
4. Abort ISSU on both nodes
5. Reboot the rolled back node
{primary:node1}

Upgrade failure on No service downtime occurs, because the secondary node fails over as primary and
primary continues to provide required services.

Reboot failure on Before the reboot of the primary node, devices being out of the ISSU setup, no ISSU-
primary node related error messages are displayed. The following reboot error message is displayed if
any other failure is detected:

Reboot failure on Before the reboot of primary node, devices will be out of ISSU
setup and no primary node error messages will be displayed.
Primary node
527

ISSU Support-Related Errors

IN THIS SECTION

Problem | 527

Solution | 527

Problem

Description

Installation failure occurs because of unsupported software and unsupported feature configuration.

Solution

Use the following error messages to understand the compatibility-related problems:

WARNING: Current configuration not compatible with /var/tmp/junos-srx5000-11.4X3.2-domestic.tgz


Exiting in-service-upgrade window
Exiting in-service-upgrade window

Initial Validation Checks Failure

IN THIS SECTION

Problem | 527

Solution | 528

Problem

Description

The initial validation checks fail.


528

Solution

The validation checks fail if the image is not present or if the image file is corrupt. The following error
messages are displayed when initial validation checks fail when the image is not present and the ISSU is
aborted:

When Image Is Not Present

user@host> ...0120914_srx_12q1_major2.2-539764-domestic.tgz reboot


Chassis ISSU Started
Chassis ISSU Started
ISSU: Validating Image
Initiating in-service-upgrade
Initiating in-service-upgrade
Fetching package...
error: File does not exist: /var/tmp/junos-srx1k3k-12.1I20120914_srx_12q1_major2.2-539764-
domestic.tgz
error: Couldn't retrieve package /var/tmp/junos-srx1k3k-12.1I20120914_srx_12q1_major2.2-539764-
domestic.tgz
Exiting in-service-upgrade window
Exiting in-service-upgrade window
Chassis ISSU Aborted
Chassis ISSU Aborted
Chassis ISSU Aborted
ISSU: IDLE
ISSU aborted; exiting ISSU window.

When Image File Is Corrupted

If the image file is corrupted, the following output displays:

user@host> ...junos-srx1k3k-11.4X9-domestic.tgz_1 reboot


Chassis ISSU Started
node1:
--------------------------------------------------------------------------
Chassis ISSU Started
ISSU: Validating Image
Initiating in-service-upgrade

node1:
--------------------------------------------------------------------------
529

Initiating in-service-upgrade
ERROR: Cannot use /var/tmp/junos-srx1k3k-11.4X9-domestic.tgz_1:
gzip: stdin: invalid compressed data--format violated
tar: Child returned status 1
tar: Error exit delayed from previous errors
ERROR: It may have been corrupted during download.
ERROR: Please try again, making sure to use a binary transfer.
Exiting in-service-upgrade window

node1:
--------------------------------------------------------------------------
Exiting in-service-upgrade window
Chassis ISSU Aborted
Chassis ISSU Aborted

node1:
--------------------------------------------------------------------------
Chassis ISSU Aborted
ISSU: IDLE
ISSU aborted; exiting ISSU window.

{primary:node0}

The primary node validates the device configuration to ensure that it can be committed using the new
software version. If anything goes wrong, the ISSU aborts and error messages are displayed.

Installation-Related Errors

IN THIS SECTION

Problem | 529

Solution | 530

Problem

Description

The install image file does not exist or the remote site is inaccessible.
530

Solution

Use the following error messages to understand the installation-related problems:

error: File does not exist: /var/tmp/junos-srx5000-11.4X3.2-domest


error: Couldn't retrieve package /var/tmp/junos-srx5000-11.4X3.2-domest

ISSU downloads the install image as specified in the ISSU command as an argument. The image file can
be a local file or located at a remote site. If the file does not exist or the remote site is inaccessible, an
error is reported.

Redundancy Group Failover Errors

IN THIS SECTION

Problem | 530

Solution | 530

Problem

Description

Problem with automatic redundancy group (RG) failure.

Solution

Use the following error messages to understand the problem:

failover all RG 1+ groups to node 0


error: Command failed. None of the redundancy-groups has been failed over.
Some redundancy-groups on node1 are already in manual failover mode.
Please execute 'failover reset all' first..
531

Kernel State Synchronization Errors

IN THIS SECTION

Problem | 531

Solution | 531

Problem

Description

Errors related to ksyncd.

Solution

Use the following error messages to understand the issues related to ksyncd:

Failed to get kernel-replication error information from Standby Routing Engine.


mgd_slave_peer_has_errors() returns error at line 4414 in mgd_package_issu.

ISSU checks whether there are any ksyncd errors on the secondary node (node 1) and displays the error
message if there are any problems and aborts the upgrade.

Managing Chassis Cluster ISSU-Related Problems

IN THIS SECTION

Viewing ISSU Progress | 532

Stopping ISSU Process if it Halts During an Upgrade | 533

Recovering the Node in Case of a Failed ISSU | 534

This topic includes the following sections:


532

Viewing ISSU Progress

IN THIS SECTION

Problem | 532

Solution | 532

Problem

Description

Rather than wait for an ISSU failure, you can display the progress of the ISSU as it occurs, noting any
message indicating that the ISSU was unsuccessful. Providing such messages to JTAC can help with
resolving the issue.

Solution

After starting an ISSU, issue the show chassis cluster information issu command. Output similar to the
following is displayed indicating the progress of the ISSU for all Services Processing Units (SPUs).

Note: Any management session to secondary node will be disconnected.


Shutdown NOW!
[pid 2480]
ISSU: Backup RE Prepare Done
Waiting for node1 to reboot.
Current time: Tue Apr 22 14:37:32 2014
Max. time to complete: 15min 0sec.
Note: For real time ISSU status, open a new management session and run
<show chassis cluster information issu> for detail information
node1 booted up.
Waiting for node1 to become secondary
Current time: Tue Apr 22 14:40:32 2014
Max. time to complete: 60min 0sec.
Note: For real time ISSU status, open a new management session and run
<show chassis cluster information issu> for detail information
node1 became secondary.
Waiting for node1 to be ready for failover
533

ISSU: Preparing Daemons


Current time: Tue Apr 22 14:41:27 2014
Max. time to complete: 60min 0sec.
Note: For real time ISSU status, open a new management session and run
<show chassis cluster information issu> for detail information
Secondary node1 ready for failover.
Installing package '/var/tmp/junos-srx5000-12.1I20140421_srx_12q1_x47.0-643920-domestic.tgz' ...
Verified SHA1 checksum of issu-indb.tgz
Verified junos-boot-srx5000-12.1I20140421_srx_12q1_x47.0-643920.tgz signed by
PackageDevelopment_12_1_0
Verified junos-srx5000-12.1I20140421_srx_12q1_x47.0-643920-domestic signed by
PackageDevelopment_12_1_0

Stopping ISSU Process if it Halts During an Upgrade

IN THIS SECTION

Problem | 533

Solution | 533

Problem

Description

The ISSU process halts in the middle of an upgrade.

Solution

If the ISSU fails to complete and only one device in the cluster is upgraded, you can roll back to the
previous configuration on the upgraded device alone by issuing one of the following commands on the
upgraded device:

• request chassis cluster in-service-upgrade abort to terminate the ISSU on both nodes.

• request system software rollback node node-id reboot to roll back the image.

• request system reboot to reboot the rolled back node.


534

Recovering the Node in Case of a Failed ISSU

IN THIS SECTION

Problem | 534

Solution | 534

Problem

Description

The ISSU procedure stops progressing.

Solution

Open a new session on the primary device and issue the request chassis cluster in-service-upgrade abort
command.

This step terminates an in-progress ISSU . This command must be issued from a session other than the
one on which you issued the request system in-service-upgrade command that launched the ISSU. If the
node is being upgraded, this command cancels the upgrade. The command is also helpful in recovering
the node in case of a failed ISSU.

When an ISSU encounters an unexpected situation that necessitates a termination, the system message
provides you with detailed information about when and why the upgrade stopped along with
recommendations for the next steps to take.

For example, the following message is issued when a node fails to become RG-0 secondary when it
boots up:

Rebooting Secondary Node


Shutdown NOW!
[pid 2120]
ISSU: Backup RE Prepare Done
Waiting for node1 to reboot.
node1 booted up.
Waiting for node1 to become secondary
error: wait for node1 to become secondary failed (error-code: 5.1)
ISSU aborted. But, both nodes are in ISSU window.
Please do the following:
535

1. Log on to the upgraded node.


2. Rollback the image using rollback command with node option
Note: Not using the 'node' option might cause
the images on both nodes to be rolled back
3. Make sure that both nodes (will) have the same image
4. Ensure the node with older image is primary for all RGs
5. Abort ISSU on both nodes
6. Reboot the rolled back node
{primary:node0}

If you attempt to upgrade a device pair running a Junos OS release earlier than Release 9.6, ISSU fails
without changing anything on either device in the cluster. Devices running Junos OS releases earlier
than Release 9.6 must be upgraded separately using individual device upgrade procedures.

If the secondary device experiences a power-off condition before it boots up using the new image
specified when the ISSU was initiated, the newly upgraded device will still be waiting to end the ISSU
after power is restored. To end the ISSU process on Routing Engine3 and Routing Engine2 on both the
nodes, issue the request chassis cluster in-service-upgrade abort command.

Release History Table


Release Description

17.4R1 Starting with Junos OS Release 17.4R1, SRX4600 devices support ISSU.

17.4R1 Starting with Junos OS Release 17.4R1, the hold timer for the initial reboot of the secondary node
during the ISSU process is extended from 15 minutes (900 seconds) to 45 minutes (2700 seconds)
in chassis clusters on SRX1500, SRX4100, SRX4200, and SRX4600 devices.

15.1X49-D80 Starting with Junos OS Release 15.1X49-D80, SRX4100 and SRX4200 devices support ISSU.

15.1X49-D80 Starting with Junos OS Release 15.1X49-D80, SRX4100 and SRX4200 devices support ISSU.

15.1X49-D70 Starting with Junos OS Release 15.1X49-D70, SRX1500 devices support ISSU.

15.1X49-D70 Starting with Junos OS Release 15.1X49-D70, SRX1500 devices support ISSU.

RELATED DOCUMENTATION

Upgrading Individual Devices in a Chassis Cluster Separately | 509


Upgrading Devices in a Chassis Cluster Using ICU | 509
Disabling a Chassis Cluster | 536
536

Disabling a Chassis Cluster

If you want to operate the SRX Series Firewall back as a standalone device or to remove a node from a
chassis cluster, you must disable the chassis cluster.

The node could fail to load the configuration if you disable the cluster and the configuration contains
groups 'node0', 'node1' defining key resources. These groups (automatically generated in case of a
cluster) will exist no more and the resulting configuration could be inconsistent.

In such events, the node will come up partially amnesiac (logins will be remembered).

To disable chassis cluster, enter the following command:

{primary:node1}
user@host> set chassis cluster disable reboot
Successfully disabled chassis cluster. Going to reboot now.

After the system reboots, the chassis cluster is disabled.

After the chassis cluster is disabled using this CLI command, you do not have a similar CLI option to
enable it back.

To restore the chassis cluster, set the cluster-id by entering the following command:

{primary:node1}
user@host> set chassis cluster cluster-id cluster-id-number node node-number reboot

When setting the cluster, the secondary node PFEMAN process will restart.

You can also use the below CLI commands to disable chassis cluster:

• To disable cluster on node 0:

user@host> set chassis cluster cluster-id 0 node 0 reboot

• To disable cluster on node 1:

user@host> set chassis cluster cluster-id 0 node 1 reboot

Setting cluster-id to zero disables clustering on a device.


537

RELATED DOCUMENTATION

Upgrading Individual Devices in a Chassis Cluster Separately | 509


Upgrading Devices in a Chassis Cluster Using ICU | 509
set chassis cluster disable reboot | 778
set chassis cluster cluster-id node node-number reboot | 780
6 CHAPTER

Troubleshooting

Troubleshooting a Control Link Failure in an SRX Chassis Cluster | 539

Troubleshooting a Fabric Link Failure in an SRX Chassis Cluster | 541

Troubleshooting a Redundancy Group that Does Not Fail Over in an SRX Chassis
Cluster | 544

Troubleshooting an SRX Chassis Cluster with One Node in the Primary State and
the Other Node in the Disabled State | 549

Troubleshooting an SRX Chassis Cluster with One Node in the Primary State and
the Other Node in the Lost State | 553

Troubleshooting an SRX Chassis Cluster with One Node in the Hold State and the
Other Node in the Lost State | 556

Troubleshooting Chassis Cluster Management Issues | 560

Data Collection for Customer Support | 585


539

Troubleshooting a Control Link Failure in an SRX


Chassis Cluster

IN THIS SECTION

Problem | 539

Diagnosis | 540

Problem

Description

The control link fails to come up in an SRX chassis cluster.

Environment

SRX chassis cluster

Symptoms

The chassis cluster is down due to a control link failure. The status of the control link is displayed as down
in the output of the show chassis cluster interfaces command. Here are sample outputs for an SRX branch
device and a high-end SRX device.

{primary:node0}
root@J-SRX-branch> show chassis cluster interfaces
Control link 0 name: fxp1
Control link status: Down

{primary:node0}
root@J-SRX-highend> show chassis cluster interfaces
Control link 0 name: em0
540

Control link 1 name: em1


Control link status: Down

Diagnosis

1. Are the control link ports connected through a switch?

• Yes: Remove the switch and connect the control link ports directly. Reboot the secondary node
and check whether the control link is up.

• If the link is up, then there might be an issue in the chassis cluster setup on the Layer 2 switch
network. See SRX Series Gateway Cluster Deployment in Layer 2 Network.

• If the link is down, proceed to Step 2.

• No: Proceed to Step 2.

2. Are the link LEDs for the control link ports on both the nodes lit green?

• Yes: Proceed to Step 4.

• No: The control link cable might be faulty. Proceed to Step 3.

3. Change the cable connecting the control link ports and check the link LED. Is the LED lit green?

• Yes: This indicates that the original cable was faulty. Reboot both the nodes simultaneously to
come out of the bad state. If the control link does not come up after the reboot, proceed to Step
4.

• No: Open a case with your technical support representative to resolve the issue. Proceed to "Data
Collection for Customer Support" on page 585.

4. Is this device an SRX5400, SRX5600, or SRX5800?

• Yes: Reconfigure the control link on a different Services Processing Card (SPC), connect the cable
to the new port, and reboot both the nodes.

a. Check whether the control link status is up:

• If the link is up, the issue is resolved.

There might be a hardware issue with the SPC. Open a case with your technical support
representative to resolve the hardware issue. Proceed to "Data Collection for Customer
Support" on page 585.

• If the link is still down, the transceivers might be faulty. Proceed to Step 5.
541

• No: Verify that the correct ports are connected (see the following table):

Port Type Port

Management (fxp0) An Ethernet port on the Routing Engine

HA Control • Port 0 (fiber only) on SPC—em0


(fxp1 or em0/em1)
• Port 1 (fiber only) on SPC—em1

Fabric Any available ge or xe interface (fiber only)


(fab0 and fab1)

If the ports are connected correctly, and the link is still down, proceed to Step 5.

5. If the control link port is an SFP or XFP port, change the transceivers on both the nodes. Ensure that
you use transceivers provided by Juniper Networks and that the transceivers are of the same type
(such as LX or SX). Is the control link up now?

• Yes: The issue is resolved.

The transceiver might be faulty. Open a case with your technical support representative to
resolve the issue with the transceivers. Proceed to "Data Collection for Customer Support" on
page 585.

• No: Continue to troubleshoot this issue with your technical support representative. Proceed to
"Data Collection for Customer Support" on page 585.

Troubleshooting a Fabric Link Failure in an SRX


Chassis Cluster

IN THIS SECTION

Problem | 542

Diagnosis | 543
542

Problem

Description

The fabric link fails to come up in an SRX chassis cluster.

Environment

SRX chassis cluster

Symptoms

The status of the fabric link is displayed as down in the output of the show chassis cluster interfaces
command. Here are sample outputs for an SRX branch device and a high-end SRX device.

{primary:node0}
root@SRX_Branch> show chassis cluster interfaces
Control link 0 name: fxp1
Control link status: Up

Fabric interfaces:
Name Child-interface Status
fab0 ge-0/0/2 down
fab0
fab1 ge-9/0/2 down
fab1
Fabric link status: down

{primary:node0}
root@SRX_HighEnd> show chassis cluster interfaces
Control link 0 name: em0
Control link 1 name: em1
Control link status: up

Fabric interfaces:
Name Child-interface Status
fab0 ge-0/0/5 down
fab0
Fabric link status: down
543

Diagnosis

1. Are the fabric link ports connected through a switch?

• Yes: Remove the switch and connect the fabric link ports directly. Reboot the secondary node and
check whether the fabric link is up.

• If the link is up, then there might be an issue in the chassis cluster setup on the Layer 2 switch
network. See SRX Series Gateway Cluster Deployment in Layer 2 Network.

• If the link is down, proceed to Step 2.

• No: Proceed to Step 2.

2. Are the link LEDs for the fabric link ports on both the nodes lit green?

• Yes: The physical link is up, but the fabric packets are not being processed. To eliminate possible
issues with the port:

a. Reconfigure the fabric link on a different port, connect the cable to the new port, and reboot
the secondary node.

b. Check whether the fabric link status is up:

• If the link is up, the issue is resolved.

There might be a hardware issue with the onboard ports or interface module ports on
which you had previously configured the fabric link. Verify the interface statistics by using
the show interfaces interface-name command. Open a case with your technical support
representative to resolve the issue with the ports. Proceed to "Data Collection for
Customer Support" on page 585.

• If the link is still down, open a case with your technical support representative. Proceed to
"Data Collection for Customer Support" on page 585.

• No: The fabric link cable might be faulty. Proceed to Step 3.

3. Change the cable connecting the fabric link ports and check the link LED. Is the LED lit green?

• Yes: This indicates that the original cable was faulty. Reboot both the nodes simultaneously to
come out of the bad state. If the fabric link does not come up after the reboot:

a. Reconfigure the fabric link on a different port, connect the cable to the new port, and reboot
the secondary node.

b. Check whether the fabric link status is up:

• If the link is up, the issue is resolved.


544

There might be a hardware issue with the onboard ports or interface module ports on
which you had previously configured the fabric link. Verify the interface statistics by using
the show interfaces interface-name command. Open a case with your technical support
representative to resolve the issue with the ports. Proceed to "Data Collection for
Customer Support" on page 585.

• If the link is still down, open a case with your technical support representative. Proceed to
"Data Collection for Customer Support" on page 585.

• No: The transceivers might be faulty. Proceed to step 4.

4. If the fabric link port is an SFP or XFP port, change the transceivers on both the nodes. Ensure that
you use transceivers provided by Juniper Networks and that the transceivers are of the same type
(such as LX or SX). Is the fabric link up now?

• Yes: The issue is resolved.

The original transceivers used on the fabric link ports might be faulty. Open a case with your
technical support representative to resolve the issue with the transceivers. Proceed to "Data
Collection for Customer Support" on page 585.

• No: Continue to troubleshoot this issue with your technical support representative. Proceed to
"Data Collection for Customer Support" on page 585.

Troubleshooting a Redundancy Group that Does Not


Fail Over in an SRX Chassis Cluster

IN THIS SECTION

Problem | 545

Diagnosis | 545

Resolution | 546

What's Next | 548


545

Problem

Description

A redundancy group (RG) in a high-availability (HA) SRX chassis cluster does not fail over.

Environment

SRX chassis cluster

Diagnosis

From the command prompt of the SRX Series Services Gateway that is part of the chassis cluster, run
the show chassis cluster status command.

Sample output:

Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 0


node0 150 primary no no
node1 100 secondary no no

Redundancy group: 1 , Failover count: 0


node0 255 primary yes no
node1 100 secondary yes no

In the sample output check the priority of the redundancy group that does not fail over.

• If the Priority is 255 and the Manual failover field is yes, proceed to "Redundancy Group Manual
Failover" on page 546.

• If the priority is 0 or anything between 1 and 254, proceed to "Redundancy Group Auto Failover" on
page 547
546

Resolution

Redundancy Group Manual Failover

1. Check whether a manual failover of the redundancy group was initiated earlier by using the show
chassis cluster status command.

Sample output:

Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 0


node0 150 primary yes no
node1 100 secondary yes no

Redundancy group: 1 , Failover count: 0


node0 255 primary no yes
node1 100 secondary no yes

In the sample output, Priority value of redundancy group 1 (RG1) is 255 and the status of Manual
failover is yes, which means that a manual failover of the redundancy group was initiated earlier. You
must reset the redundancy group priority.

NOTE: After a manual failover of a redundancy group, we recommend that you reset the
manual failover flag in the cluster status to allow further failovers.

2. Reset the redundancy group priority by using the request chassis cluster failover reset redundancy-group
<1-128>.

For example:

user@host> request chassis cluster failover reset redundancy-group 1


root@srx> request chassis cluster failover reset redundancy-group 1
node0:
--------------------------------------------------------------------------
Successfully reset manual failover for redundancy group 1
547

node1:
--------------------------------------------------------------------------
No reset required for redundancy group 1.

3. This must resolve the issue and allow further redundancy group failovers. If these steps do not
resolve the issue, proceed to section Whats Next.

4. If you want to initiate a redundancy group x (redundancy groups numbered 1 through 128) failover
manually, see Understanding Chassis Cluster Redundancy Group Manual Failover.

Redundancy Group Auto Failover

1. Check the configuration and link status of the control and fabric links by using the show chassis cluster
interfaces command.

Sample output for a branch SRX Series Services Gateway:

{primary:node0}
root@SRX_Branch> show chassis cluster interfaces
Control link 0 name: fxp1
Control link status: Up

Fabric interfaces:
Name Child-interface Status
fab0 ge-0/0/2 down
fab0
fab1 ge-9/0/2 down
fab1
Fabric link status: down

Sample output for a high-end SRX Series Services Gateway:

{primary:node0}
root@SRX_HighEnd> show chassis cluster interfaces
Control link 0 name: em0
Control link 1 name: em1
Control link status: up
548

Fabric interfaces:
Name Child-interface Status
fab0 ge-0/0/5 down
fab0
Fabric link status: down

• If the control link is down, see KB article KB20698 to troubleshoot and bring up the control link
and proceed to "3" on page 548.

• If the fabric link is down, see "Troubleshooting a Fabric Link Failure in an SRX Chassis Cluster" on
page 541 to troubleshoot and bring up the fabric link and proceed to "3" on page 548.

2. Proceed to Step "3" on page 548 if both the control link and fabric link are up.

3. Check the interface monitoring or IP monitoring configurations that are up. If the configurations are
not correct rectify the configurations. If the configurations are correct proceed to step "4" on page
548.

4. Check the priority of each node in the output of the show chassis cluster status command.

• If the priority is 0, see KB article KB16869 for JSRP (Junos OS Services Redundancy Protocol)
chassis clusters and KB article KB19431 for branch SRX Series Firewalls.

• If the priority is 255, see "Redundancy Group Manual Failover" on page 546.

• If the priority is between 1 and 254 and if still the redundancy group does not fail over, proceed to
the section Whats Next.

WHAT'S NEXT

If these steps do not resolve the issue, see KB article KB15911 for redundancy group failover tips.

If you wish to debug further, see KB article KB21164 to check the debug logs.

To open a JTAC case with the Juniper Networks Support team, see "Data Collection for Customer
Support" | 585 for the data you should collect to assist in troubleshooting before you open a JTAC
case.
549

Troubleshooting an SRX Chassis Cluster with One


Node in the Primary State and the Other Node in
the Disabled State

IN THIS SECTION

Problem | 549

Diagnosis | 550

Problem

Description

The nodes of the SRX chassis cluster are in primary and disabled states.

Environment

SRX chassis cluster

Symptoms

One node of the cluster is in the primary state and the other node is in the disabled state. Run the show
chassis cluster status command on each node to view the status of the node. Here is a sample output:

{primary:node0}
root@primary-srx> show chassis cluster status
Monitor Failure codes:
CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
550

CF Config Sync monitoring RE Relinquish monitoring

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 255 primary no no None
node1 129 disabled no no None

Redundancy group: 1 , Failover count: 1


node0 255 primary no no None
node1 129 disabled no no None

Diagnosis

1. Run the show chassis cluster interfaces command to verify the status of the control and fabric links. Are
any of the links down?

Here are sample outputs for a branch SRX Series Firewall and a high-end SRX Series Firewall.

root@Branch-SRX> show chassis cluster interfaces


Control link 0 name: fxp1
Control link status: Up

Fabric interfaces:
Name Child-interface Status
fab0 ge-0/0/2 up
fab0 ge-2/0/6 up
fab1 ge-9/0/2 up
fab1 ge-11/0/6 up
Fabric link status: Up

{primary:node0}
root@High-end-SRX> show chassis cluster interfaces
Control link 0 name: em0
Control link 1 name: em1
Control link status: Up
551

Fabric interfaces:
Name Child-interface Status
fab0 ge-2/0/0 down
fab0
fab1
fab1
Fabric link status: Up

• Yes: See "Troubleshooting a Fabric Link Failure in an SRX Chassis Cluster" on page 541 or
"Troubleshooting a Control Link Failure in an SRX Chassis Cluster" on page 539.

• No: Proceed to Step 2.

2. Reboot the disabled node. Does the node come up in the disabled state after the reboot?

• Yes: There might be hardware issues. Proceed to Step 3.

• No: The issue is resolved.

3. Check the node for any hardware issues. Run the show chassis fpc pic-status command on both nodes,
and ensure that the FPCs are online. Do you see the status of any FPC listed as Present, OK, or Offline?

Here is a sample output.

{primary:node1}
root@J-SRX> show chassis fpc pic-status
node0:
--------------------------------------------------------------------------
Slot 0 Online FPC
PIC 0 Online 4x GE Base PIC
Slot 2 Online FPC
PIC 0 Online 24x GE gPIM
Slot 6 Online FPC
PIC 0 Online 2x 10G gPIM

node1:
--------------------------------------------------------------------------
Slot 0 Online FPC
PIC 0 Online 4x GE Base PIC
Slot 2 Online FPC
PIC 0 Online 24x GE gPIM
Slot 6 Online FPC
PIC 0 Online 2x 10G gPIM
552

• Yes: Reseat the cards and reboot the node. If this does not resolve the issue, open a case with
your technical support representative for further troubleshooting. See "Data Collection for
Customer Support" on page 585.

• No: Proceed to Step 4.

4. Run the show chassis cluster statistics on both nodes, and analyze the output.

{primary:node0}
root@J-SRX> show chassis cluster statistics
Control link statistics:
Control link 0:
Heartbeat packets sent: 418410
Heartbeat packets received: 418406
Heartbeat packet errors: 0
Fabric link statistics:
Probes sent: 418407
Probes received: 414896
Probe errors: 0

Does the Heartbeat packets received field show a non-increasing value or zero (0), or does the Heartbeat
packet errors field show a non-zero value?

• Yes: Open a case with your technical support representative for further troubleshooting. See
"Data Collection for Customer Support" on page 585.

• No: Proceed to Step 5.

5. Configure set chassis cluster no-fabric-monitoring (hidden option) and commit the configuration to
temporarily disable fabric monitoring during the troubleshooting process. Reboot the disabled node.
After the node reboots, run the show chassis cluster statistics command. Are the probes still lost?

• Yes: Open a case with your technical support representative for further troubleshooting. See
"Data Collection for Customer Support" on page 585

• No: Delete the set chassis cluster no-fabric-monitoring configuration, and verify that everything is
operational. If you notice any issue, open a case with your technical support representative for
further troubleshooting. See "Data Collection for Customer Support" on page 585
553

Troubleshooting an SRX Chassis Cluster with One


Node in the Primary State and the Other Node in
the Lost State

IN THIS SECTION

Problem | 553

Diagnosis | 554

Problem

Description

The nodes of the SRX chassis cluster are in primary and lost states.

Environment

SRX chassis cluster

Symptoms

One node of the cluster is in the primary state and the other node is in the lost state. Run the show
chassis cluster status command on each node to view the status of the node. Here is a sample output:

{primary:node0}
root@primary-srx> show chassis cluster status
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 100 primary no no
node1 0 lost no no
554

Redundancy group: 1 , Failover count: 1


node0 100 primary no no
node1 0 lost no no

Diagnosis

1. Is the node that is in the lost state powered on?

• Yes: Are you able to access the node that is in the lost state through a console port? Do not use
Telnet or SSH to access the node.

• If you are able to access the node, proceed to Step 3.

• If you are unable to access the node and if the device is at a remote location, access the node
through a console for further troubleshooting. If you have console access, but do not see any
output, it might indicate a hardware issue. Open a case with your technical support
representative for further troubleshooting. See "Data Collection for Customer Support" on
page 585.

• No: Power on the node and proceed to Step 2.

2. After both nodes are powered on, run the show chassis cluster status command again. Is the node still
in the lost state?

• Yes: Are you able to access the node that is in the lost state through a console port? Do not use
Telnet or SSH to access the node.

• If you are able to access the node, proceed to Step 3.

• If you are unable to access the node and if the node is at a remote location, access the node
through a console for further troubleshooting. If you have console access, but do not see any
output, it might indicate a hardware issue. Open a case with your technical support
representative for further troubleshooting. See "Data Collection for Customer Support" on
page 585.

• No: Powering on the device has resolved the issue.

3. Connect a console to the primary node, and run the show chassis cluster status command. Does the
output show this node as primary and the other node as lost?

• Yes: This might indicate a split-brain scenario. Each node would show itself as primary and the
other node as lost. Run the following commands to verify which node is processing the traffic:

• show security monitoring


555

• show security flow session summary

• monitor interface traffic

Isolate the node that is not processing the traffic. You can isolate the node from the network by
removing all the cables except the control and fabric links. Proceed to Step 4.

• No: Proceed to Step 4.

4. Verify that all the FPCs are online on the node that is in the lost state by running the show chassis fpc
pic-status command. Are all the FPCs online?

• Yes: Proceed to Step 5.

• No: Open a case with your technical support representative for further troubleshooting. See
"Data Collection for Customer Support" on page 585.

5. Are the nodes connected through a switch?

• Yes: See "Troubleshooting a Fabric Link Failure in an SRX Chassis Cluster" on page 541 and
"Troubleshooting a Control Link Failure in an SRX Chassis Cluster" on page 539.

• No: Proceed to Step 6.

6. Create a backup of the configuration from the node that is currently primary:

{primary:node0}
root@primary-srx# show configuration | save /var/tmp/cfg-bkp.txt

Copy the configuration to the node that is in the lost state, and load the configuration:

root@lost-srx# load override <terminal or filename>

NOTE: If you use the terminal option, paste the complete configuration into the window. Make
sure that you use Ctrl+D at the end of the configuration.
If you use the filename option, provide the path to the configuration file (for
example: /var/tmp/Primary_saved.conf), and press Enter.

When you connect to the node in the lost state through a console, you might see the state as either
primary or hold/disabled. If the node is in the hold/disabled state, a fabric link failure might have
occurred before the device went into the lost state. To troubleshoot this issue, follow the steps in
"Troubleshooting a Fabric Link Failure in an SRX Chassis Cluster" on page 541.
556

Commit the changes after the configuration is loaded. If the problem persists, then replace the
existing control and fabric links on this device with new cables and reboot the node:

{primary:node1}[edit]
root@lost-srx# request system reboot

Is the issue resolved?

• No: Open a case with your technical support representative for further troubleshooting. See
"Data Collection for Customer Support" on page 585.

Troubleshooting an SRX Chassis Cluster with One


Node in the Hold State and the Other Node in the
Lost State

IN THIS SECTION

Problem | 556

Cause | 557

Resolution | 558

Problem

Description

The nodes of the SRX chassis cluster are in hold and lost states.

Environment

SRX chassis cluster


557

Symptoms

One node of the SRX chassis cluster is in the hold state and the other node is in the lost state after you
connect the cables and reboot the devices in cluster mode. Run the show chassis cluster status command
on each node to view the status of the node. Here is a sample output:

{hold:node0} user@node0> show chassis cluster status

Cluster ID: 1, Redundancy-group: 0


Node name Priority Status Preempt Manual failover
node0 100 hold No No
node1 1 lost No No

{hold:node1}
user@node1> show chassis cluster status
Cluster ID: 1, Redundancy-group: 0
Node name Priority Status Preempt Manual failover
node0 100 lost No No
node1 1 hold No No

If the status of a node is hold, the node is not ready to operate in a chassis cluster.

NOTE: This issue does not impact high-end SRX Series Firewalls because these devices have
dedicated control and management ports.

Cause

When you boot a branch SRX Series Firewall in cluster mode, two revenue interfaces (depending upon
the model of the device) are designated for the out-of-band management link (fxp0) and control link
(fxp1) of the chassis cluster. The fxp0 and fxp1 ports cannot be used for transit traffic.

If you configure the fxp0 and fxp1 ports, the chassis cluster goes into the hold/lost state. The following
table lists the ports that are designated as fxp0 and fxp1 ports for branch SRX Series Firewalls:
558

Table 38: fxp0 and fxp1 Ports on Branch SRX Series Devices

Device Management (fxp0) HA Control (fxp1) Fabric (fab0 and fab1)—must be configured

SRX300 ge-0/0/0 ge-0/0/1 Any ge interface

SRX320 ge-0/0/0 ge-0/0/1 Any ge interface

SRX340, SRX345, and MGMT ge-0/0/1 Any ge interface


SRX380

SRX550 HM ge-0/0/0 ge-0/0/1 Any ge or xe interface

Resolution

Remove the Configuration on a Device Running the Factory-Default Configuration

The factory-default configuration includes configuration for the interfaces that are transformed into
fxp0 and fxp1 interfaces. You must delete these configurations before enabling chassis cluster mode. A
device can have the factory-default configuration in the following scenarios:

• Typically, new devices are used in a chassis cluster. These new devices ship with the factory-default
configuration, which includes configuration for the interfaces.

• If a device that is in chassis cluster mode crashes, the device might come up with the factory-default
configuration.

To remove the configuration on the interfaces, delete the factory-default configuration and reconfigure
the device.

CAUTION: The following procedure removes the current configuration.

1. Log in to the device and enter the configuration mode.


559

2. Run the delete command to delete the current configuration from the device.

root# delete
This will delete the entire configuration
Delete everything under this level? [yes,no] (no) yes

3. Configure the root password and commit the configuration:

root# set system root-authentication plain-text-password


root# commit

Remove the Configuration on a Device Operating as a Standalone Device

If the device is currently running in a production environment, then check whether the interfaces that
are designated as the fxp0 and fxp1 interfaces are configured. To determine which interfaces are
transformed into fxp0 and fxp1 interfaces, see Table 38 on page 558.

1. Run the following commands to list the configuration for the fxp0 and fxp1 interfaces:

show | display set | match <physical interface of the control port (fxp1)>
show | display set | match <physical interface of the management port (fxp0)>

For example:

show configuration | display set | match ge-0/0/0


show configuration | display set | match ge-0/0/1

2. Delete all the configurations related to the interfaces from every configuration hierarchy.

You can also choose to delete the entire configuration and reconfigure the device:

root# delete
560

Troubleshooting Chassis Cluster Management Issues

IN THIS SECTION

Unable to Manage an SRX Series Chassis Cluster Using the Management Port or Revenue Ports | 560

Unable to Manage the Secondary Node of a Chassis Cluster Using J-Web | 572

Unable to Manage an SRX Series Chassis Cluster Using fxp0 When the Destination in the Backup Router is
0/0 | 574

Unable to Upgrade a Chassis Cluster Using In-Service Software Upgrade | 580

Configuring backup-router Command on Chassis Cluster | 582

Unable to Upgrade a Chassis Cluster Using In-Service Software Upgrade | 583

Unable to Manage an SRX Series Chassis Cluster Using the Management


Port or Revenue Ports

IN THIS SECTION

Problem | 560

Diagnosis | 561

Resolution | 561

Problem

Description

Cannot manage the SRX Series chassis cluster using the management port or revenue ports.

Environment

SRX Series chassis cluster


561

Diagnosis

1. Which node in the chassis cluster are you using to manage the cluster?

• Primary node—Proceed to:

• Manage the Chassis Cluster Using J-Web.

NOTE: You can use J-Web to manage only the primary node.

• Manage the Chassis Cluster Using the Revenue Port or fxp0 Management Port.

NOTE: You can use the revenue port or fxp0 management port to manage the primary
node.

• Secondary node—Proceed to "Manage the Chassis Cluster Using the fxp0 Management Port" on
page 570

NOTE: You can manage the secondary node only by using the fxp0 management port.

Resolution

Manage the Chassis Cluster Using J-Web

NOTE: You can use J-Web to manage only the primary node.

1. Connect a console to the primary node.

2. Using the CLI, run the show system services web-management command.

3. Check whether the loopback interface (lo0) is configured under the Web management HTTP/HTTPS
configuration. See web-management (System Services) .

4. If the loopback interface (lo0) is configured under the Web management HTTP/HTTPS configuration,
remove the loopback interface by running the delete system services web-management http interface lo.0
command.

5. Commit the change, and check whether you can now manage the chassis cluster.
562

6. If you still cannot manage the chassis cluster, proceed to "Manage Chassis Cluster Using the Revenue
Port or fxp0 Management Port" on page 567.

Manage Chassis Cluster Using the Revenue Port or fxp0 Management Port

NOTE: You can use both the revenue port or fxp0 management port to manage the primary
node.

1. Connect to a console using the revenue port of the primary node which you want to use as a
management interface.

2. Verify the configuration of the management interface:

a. Verify that the required system services (SSH, Telnet, HTTP) are enabled at the host-inbound-
traffic hierarchy level in the relevant zone:

zones {
security-zone trust {
host-inbound-traffic {
system-services {
any-service;
}
protocols {
all;
}
}
interfaces {
reth0.0
reth0.1;
}
}

b. Verify that the required system services (SSH, Telnet, HTTP) are enabled at the system services
hierarchy level:

{primary:node1}[edit]
root# show system services {
http;
ssh;
563

telnet;
}

3. Does ping to the management interface work?

• Yes: See Unable to Manage an SRX Series Chassis Cluster Using fxp0 When the Destination in the
Backup Router is 0/0. If this solution doesn't work, proceed to "What’s Next" on page 571 to
open a case with Juniper Networks technical support.

• No: Proceed to step "4" on page 563.

4. Using the CLI, run the show interfaces terse command:

In the output, is the status of FXP0 interface Up, and does it provide an IP address?

• Yes: Proceed to step "5" on page 564.

• No: Verify the following:

a. Using the CLI, verify that the fxp0 interface is configured correctly: show groups.

Sample output:

root@srx# show groups


node0 {
system {
host-name SRX3400-1;
backup-router 192.168.1.254 destination 0.0.0.0/0;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.1.1/24;
}
}
}
}
}
node1 {
system {
host-name SRX3400-2;
backup-router 192.168.1.254 destination 0.0.0.0/0;
}
interfaces {
564

fxp0 {
unit 0 {
family inet {
address 192.168.1.2/24;
}
}
}
}
}
}
apply-groups "${NODE}";
system {
services {
ftp;
ssh;
telnet;
}
}

b. Check the condition of the cable that is connected to the fxp0 interface. Is the cable in good
condition?

• Yes: Proceed to the next step.

• No: Replace the cable and try to manage the chassis cluster. If you still cannot manage the
chassis cluster, proceed to the next step.

c. Using the CLI, check for incrementing error counters: show interfaces fxp0.0 extensive.

• Yes: If you find any errors in the output, proceed to "What’s Next" on page 571 to open a
case with Juniper Networks technical support.

• No: If there are no errors in the output and if you still cannot manage the chassis cluster,
proceed to step "5" on page 564.

5. Check whether the IP address of the fxp0 interface and the IP address of the management device are
in the same subnet.

• Yes: Proceed to the step "6" on page 565.

• No: Using the CLI, check if there is a route for the management device IP address: show route
<management device IP>:

a. If a route does not exist for the management device IP address, add a route for the
management subnet in the inet.0 table with the next-hop as the backup router IP address.
565

6. Using the CLI, check whether there is an ARP entry for the management device on the services
gateway: show arp no-resolve | match <ip>.

a. Yes: Check whether the chassis cluster has multiple routes to the management device: show
route <device-ip>.

• Yes: There could be routes to the management device through the fxp0 interface and other
interface leading to asymmetric routing. Proceed to "What’s Next" on page 571 to open a
case with Juniper Networks technical support.

• No: Proceed to "Manage the Chassis Cluster Using the fxp0 Management Port" on page 570.

b. No: Proceed to "What’s Next" on page 571 to open a case with Juniper Networks technical
support.

Manage the Chassis Cluster Using the fxp0 Management Port

NOTE: You can use only the fxp0 management port to manage the secondary node.

1. Verify the configuration of management interface on the secondary node:

• Verify that the required system services (SSH, Telnet, HTTP) are enabled at the host-inbound-
traffic hierarchy level:

zones {
security-zone trust {
host-inbound-traffic {
system-services {
any-service;
}
protocols {
all;
}
}
interfaces {
reth0.0
reth0.1;
}
}
566

• Verify that the required system services (SSH, Telnet, HTTP) are enabled at the system services
hierarchy level:

{primary:node1}[edit]
root# show system services {
http;
ssh;
telnet;
}

See Unable to Manage an SRX Series Chassis Cluster Using fxp0 When the Destination in the
Backup Router is 0/0 and Configuring backup-router Command on Chassis Cluster for more
information about the configuration guidelines.

If the configuration is correct and you still cannot manage the chassis cluster, proceed to step "2" on
page 566.

2. Are the IP addresses of the fxp0 interfaces of the primary node and the secondary node in the same
subnet?

• Yes: Proceed to "What’s Next" on page 571.

• No: Configure the fxp0 interfaces of the primary node and the secondary node in the same
subnet. Go to step "1" on page 565 and verify the configuration.

What’s Next

• If the issue persists, see KB Article KB20795.

• If you wish to debug further, see KB Article KB21164 to check the debug logs.

• To open a JTAC case with the Juniper Networks support team, see Data Collection for Customer
Support for the data you should collect to assist in troubleshooting prior to opening a JTAC case.

Manage the Chassis Cluster Using J-Web

NOTE: You can use J-Web to manage only the primary node.

1. Connect a console to the primary node.

2. Using the CLI, run the show system services web-management command.
567

3. Check whether the loopback interface (lo0) is configured under the Web management HTTP/HTTPS
configuration. See web-management (System Services) .

4. If the loopback interface (lo0) is configured under the Web management HTTP/HTTPS configuration,
remove the loopback interface by running the delete system services web-management http interface lo.0
command.

5. Commit the change, and check whether you can now manage the chassis cluster.

6. If you still cannot manage the chassis cluster, proceed to "Manage Chassis Cluster Using the Revenue
Port or fxp0 Management Port" on page 567.

Manage Chassis Cluster Using the Revenue Port or fxp0 Management Port

NOTE: You can use both the revenue port or fxp0 management port to manage the primary
node.

1. Connect to a console using the revenue port of the primary node which you want to use as a
management interface.

2. Verify the configuration of the management interface:

a. Verify that the required system services (SSH, Telnet, HTTP) are enabled at the host-inbound-
traffic hierarchy level in the relevant zone:

zones {
security-zone trust {
host-inbound-traffic {
system-services {
any-service;
}
protocols {
all;
}
}
interfaces {
reth0.0
reth0.1;
}
}
568

b. Verify that the required system services (SSH, Telnet, HTTP) are enabled at the system services
hierarchy level:

{primary:node1}[edit]
root# show system services {
http;
ssh;
telnet;
}

3. Does ping to the management interface work?

• Yes: See Unable to Manage an SRX Series Chassis Cluster Using fxp0 When the Destination in the
Backup Router is 0/0. If this solution doesn't work, proceed to "What’s Next" on page 571 to
open a case with Juniper Networks technical support.

• No: Proceed to step "4" on page 563.

4. Using the CLI, run the show interfaces terse command:

In the output, is the status of FXP0 interface Up, and does it provide an IP address?

• Yes: Proceed to step "5" on page 564.

• No: Verify the following:

a. Using the CLI, verify that the fxp0 interface is configured correctly: show groups.

Sample output:

root@srx# show groups


node0 {
system {
host-name SRX3400-1;
backup-router 192.168.1.254 destination 0.0.0.0/0;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.1.1/24;
}
}
}
569

}
}
node1 {
system {
host-name SRX3400-2;
backup-router 192.168.1.254 destination 0.0.0.0/0;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.1.2/24;
}
}
}
}
}
}
apply-groups "${NODE}";
system {
services {
ftp;
ssh;
telnet;
}
}

b. Check the condition of the cable that is connected to the fxp0 interface. Is the cable in good
condition?

• Yes: Proceed to the next step.

• No: Replace the cable and try to manage the chassis cluster. If you still cannot manage the
chassis cluster, proceed to the next step.

c. Using the CLI, check for incrementing error counters: show interfaces fxp0.0 extensive.

• Yes: If you find any errors in the output, proceed to "What’s Next" on page 571 to open a
case with Juniper Networks technical support.

• No: If there are no errors in the output and if you still cannot manage the chassis cluster,
proceed to step "5" on page 564.

5. Check whether the IP address of the fxp0 interface and the IP address of the management device are
in the same subnet.
570

• Yes: Proceed to the step "6" on page 565.

• No: Using the CLI, check if there is a route for the management device IP address: show route
<management device IP>:

a. If a route does not exist for the management device IP address, add a route for the
management subnet in the inet.0 table with the next-hop as the backup router IP address.

6. Using the CLI, check whether there is an ARP entry for the management device on the services
gateway: show arp no-resolve | match <ip>.

a. Yes: Check whether the chassis cluster has multiple routes to the management device: show
route <device-ip>.

• Yes: There could be routes to the management device through the fxp0 interface and other
interface leading to asymmetric routing. Proceed to "What’s Next" on page 571 to open a
case with Juniper Networks technical support.

• No: Proceed to "Manage the Chassis Cluster Using the fxp0 Management Port" on page 570.

b. No: Proceed to "What’s Next" on page 571 to open a case with Juniper Networks technical
support.

Manage the Chassis Cluster Using the fxp0 Management Port

NOTE: You can use only the fxp0 management port to manage the secondary node.

1. Verify the configuration of management interface on the secondary node:

• Verify that the required system services (SSH, Telnet, HTTP) are enabled at the host-inbound-
traffic hierarchy level:

zones {
security-zone trust {
host-inbound-traffic {
system-services {
any-service;
}
protocols {
all;
}
}
interfaces {
571

reth0.0
reth0.1;
}
}

• Verify that the required system services (SSH, Telnet, HTTP) are enabled at the system services
hierarchy level:

{primary:node1}[edit]
root# show system services {
http;
ssh;
telnet;
}

See Unable to Manage an SRX Series Chassis Cluster Using fxp0 When the Destination in the
Backup Router is 0/0 and Configuring backup-router Command on Chassis Cluster for more
information about the configuration guidelines.

If the configuration is correct and you still cannot manage the chassis cluster, proceed to step "2" on
page 566.

2. Are the IP addresses of the fxp0 interfaces of the primary node and the secondary node in the same
subnet?

• Yes: Proceed to "What’s Next" on page 571.

• No: Configure the fxp0 interfaces of the primary node and the secondary node in the same
subnet. Go to step "1" on page 565 and verify the configuration.

What’s Next

• If the issue persists, see KB Article KB20795.

• If you wish to debug further, see KB Article KB21164 to check the debug logs.

• To open a JTAC case with the Juniper Networks support team, see Data Collection for Customer
Support for the data you should collect to assist in troubleshooting prior to opening a JTAC case.
572

Unable to Manage the Secondary Node of a Chassis Cluster Using J-Web

IN THIS SECTION

Problem | 572

Cause | 572

Solution | 574

Problem

Description

Cannot manage the secondary node of a chassis cluster using the J-Web interface.

Environment

SRX Series chassis cluster

Symptoms

When in the Junos Services Redundancy Protocol (JSRP) chassis cluster mode, you cannot manage
redundancy group 0 (RG0) on the secondary node using the J-Web interface.

Cause

• You can use the J-Web interface to manage redundancy group 0 only on the primary node.

• The processes that J-Web references are not running on the secondary node.

Example

The following example shows the output of syslog and system process on both node0 and node1 after
RG0 was failed over from node1 to node0.

• On node1, web-management process (httpd-gk) was terminated (exited).

• On node0, web-management process (httpd-gk) was started.


573

• Two http-related processes (httpd-gk and httpd), run only on node0, which is the new primary node
of RG0.

{secondary:node1}
root@SRX210HE-B> show chassis cluster status
Cluster ID: 1
Node Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 255 primary no yes
node1 1 secondary no yes

Redundancy group: 1 , Failover count: 1


node0 100 primary yes no
node1 1 secondary yes no
{secondary:node1}
root@SRX210HE-B> show log log-any | grep web-management
Jul 5 11:31:52 SRX210HE-B init: web-management (PID 9660) started
Jul 5 12:00:37 SRX210HE-B init: web-management (PID 9660) SIGTERM sent
Jul 5 12:00:37 SRX210HE-B init: web-management (PID 9660) exited with status=0 Normal Exit

{primary:node0}
root@SRX210HE-A> show log log-any | grep web-management
Jul 5 12:00:37 SRX210HE-A init: web-management (PID 9498) started

{primary:node0}
root@SRX210HE-A> show system processes extensive node 0 | grep http
9498 root 1 76 0 12916K 4604K select 0 0:00 0.00% httpd-gk
9535 nobody 1 90 0 8860K 3264K select 0 0:00 0.00% httpd

{primary:node0}
root@SRX210HE-A> show system processes extensive node 1 | grep http
=> No httpd-gk and httpd processes running on node 1 (secondary node)

NOTE: This limits remote procedure calls (RPCs) from the J-Web logic, and subsequently, pages
that can be issued from the secondary node.
574

Solution

You can manage the secondary node of a chassis cluster using the CLI (SSH, telnet, and console). See
Manage the Chassis Cluster Using the fxp0 Management Port

Unable to Manage an SRX Series Chassis Cluster Using fxp0 When the
Destination in the Backup Router is 0/0

SUMMARY IN THIS SECTION

This topic explains, with an example, how to Problem | 574


manage an SRX Series chassis cluster configured Cause | 576
using the backup-router configuration through the
fxp0 interface. Solution | 576

Problem

Description

The management device cannot manage the chassis cluster through an fxp0 interface, but it can ping
both fxp0 interfaces.

Sample Topology

The topology, IP addresses, and configuration are as follows:

• Primary fxp0: 192.168.1.1/24

• Secondary fxp0: 192.168.1.2/24

• Gateway for fxp0: 192.168.1.254

• Management device: 172.16.1.1/24

groups {
node0 {
system {
host-name SRX5400-1;
backup-router 192.168.1.254 destination 0.0.0.0/0;
575

}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.1.1/24;
}
}
}
}
}
node1 {
system {
host-name SRX5400-2;
backup-router 192.168.1.254 destination 0.0.0.0/0;
}
interfaces {
fxp0 {
unit 0 {
family inet {
address 192.168.1.2/24;
}
}
}
}
}
}
apply-groups "${NODE}";
system {
services {
ftp;
ssh;
telnet;
}
}

Environment

SRX Series chassis cluster


576

Cause

There is a route for 172.16.1.1 through the interfaces other than the fxp0 interface on the cluster
devices. We do not recommend using 0.0.0.0/0 as the backup-router destination. Ping works because
the echo reply for an incoming echo request to the fxp0 interface is sent out following the route for
172.16.1.1 through interfaces other than fxp0, but Telnet fails.

Solution

Remove the route for 172.16.1.1 in the routing table, and set a more specific backup-router destination
in group node0/node1.

For example:

groups {
node0 {
...
backup-router 192.168.1.254 destination 172.16.1.1/32;
...
}
node1 {
...
backup-router 192.168.1.254 destination 172.16.1.1/32;
...
}

No changes are displayed in the routing table after the configuration is applied because the backup-
router configuration is intended to facilitate management access on the backup node only. Access to the
primary node is enabled through routing on the primary node.
Thus, when the backup router configuration is complete, you can see that a route is injected into the
forwarding table on the secondary node. You cannot see the routing table on the secondary node
because the routing subsystem does not run on the secondary node.

Sample Output when the Backup router is Configured with Destination 0/0

• Routing table on primary node:

{primary:node0}[edit]
root@SRX5400-1# run show route

inet.0: 2 destinations, 2 routes (2 active, 0 holddown, 0 hidden)


+ = Active Route, - = Last Active, * = Both
577

192.168.1.0/24 *[Direct/0] 00:00:54


> via fxp0.0
192.168.1.1/32 *[Local/0] 00:00:54
Local via fxp0.0

• Forwarding table on secondary node with destination 0/0:

root@SRX3400-2# run show route forwarding-table


Routing table: default.inet
Internet:
Destination Type RtRef Next hop Type Index NhRef Netif
default user 0 28:c0:da:a0:88:0 ucst 345 2 fxp0.0
default perm 0 rjct 36 1
0.0.0.0/32 perm 0 dscd 34 1
192.168.1.0/24 intf 0 rslv 344 1 fxp0.0
192.168.1.0/32 dest 0 192.168.1.0 recv 342 1 fxp0.0
192.168.1.2/32 intf 0 192.168.1.2 locl 343 2
192.168.1.2/32 dest 0 192.168.1.2 locl 343 2
192.168.1.254/32 dest 0 28:c0:da:a0:88:0 ucst 345 2 fxp0.0
192.168.1.255/32 dest 0 192.168.1.255 bcst 336 1 fxp0.0
224.0.0.0/4 perm 0 mdsc 35 1
224.0.0.1/32 perm 0 224.0.0.1 mcst 31 1
255.255.255.255/32 perm 0 bcst 32 1

Routing table: __master.anon__.inet


Internet:
Destination Type RtRef Next hop Type Index NhRef Netif
default perm 0 rjct 526 1
0.0.0.0/32 perm 0 dscd 524 1
224.0.0.0/4 perm 0 mdsc 525 1
224.0.0.1/32 perm 0 224.0.0.1 mcst 521 1
255.255.255.255/32 perm 0 bcst 522 1

Sample Output when the Backup router is Configured with Destination 172.16.1.1/32
578

• Routing table on primary node:

{primary:node0}[edit]
root@SRX5400-1# run show route

inet.0: 2 destinations, 2 routes (2 active, 0 holddown, 0 hidden)


+ = Active Route, - = Last Active, * = Both

192.168.1.0/24 *[Direct/0] 00:17:51


> via fxp0.0
192.168.1.1/32 *[Local/0] 00:55:50
Local via fxp0.0

• Forwarding table on primary node:

NOTE: On the primary node, route 172.16.1.1/32 of the backup router is not shown in the
sample output.

{primary:node0}[edit]
root@SRX5400-1# run show route forwarding-table
Routing table: default.inet
Internet:
Destination Type RtRef Next hop Type Index NhRef Netif
default perm 0 rjct 36 1
0.0.0.0/32 perm 0 dscd 34 1
192.168.1.0/24 intf 0 rslv 334 1 fxp0.0
192.168.1.0/32 dest 0 192.168.1.0 recv 331 1 fxp0.0
192.168.1.1/32 intf 0 192.168.1.1 locl 332 2
192.168.1.1/32 dest 0 192.168.1.1 locl 332
2

192.168.1.3/32 dest 0 5c:5e:ab:16:e3:81 ucst 339 1 fxp0.0


192.168.1.6/32 dest 0 0:26:88:4f:c8:8 ucst 340 1 fxp0.0
192.168.1.11/32 dest 0 0:30:48:bc:9f:45 ucst 342 1 fxp0.0
192.168.1.254/32 dest 0 28:c0:da:a0:88:0 ucst 343 1 fxp0.0
192.168.1.255/32 dest 0 192.168.1.255 bcst 329 1 fxp0.0
224.0.0.0/4 perm 0 mdsc 35 1
224.0.0.1/32 perm 0 224.0.0.1 mcst 31 1
579

255.255.255.255/32 perm 0 bcst 32 1

Routing table: __master.anon__.inet


Internet:
Destination Type RtRef Next hop Type Index NhRef Netif
default perm 0 rjct 526 1
0.0.0.0/32 perm 0 dscd 524 1
224.0.0.0/4 perm 0 mdsc 525 1
224.0.0.1/32 perm 0 224.0.0.1 mcst 521 1
255.255.255.255/32 perm 0 bcst 522 1

• Forwarding table on the secondary node:

NOTE: On the secondary node, route 172.16.1.1/32 of the backup router is shown in the
sample output. This facilitates access to the secondary node through the fxp0 interface.

{secondary:node1}[edit]
root@SRX5400-2# run show route forwarding-table
Routing table: default.inet
Internet:
Destination Type RtRef Next hop Type Index NhRef Netif
default perm 0 rjct 36 1
0.0.0.0/32 perm 0 dscd 34 1
172.16.1.1/32 user 0 192.168.1.254 ucst 345 2 fxp0.0
192.168.1.0/24 intf 0 rslv 344 1 fxp0.0
192.168.1.0/32 dest 0 192.168.1.0 recv 342 1 fxp0.0
192.168.1.2/32 intf 0 192.168.1.2 locl 343 2
192.168.1.2/32 dest 0 192.168.1.2 locl 343 2
192.168.1.254/32 dest 0 28:c0:da:a0:88:0 ucst 345 2 fxp0.0
192.168.1.255/32 dest 0 192.168.1.255 bcst 336 1 fxp0.0
224.0.0.0/4 perm 0 mdsc 35 1
224.0.0.1/32 perm 0 224.0.0.1 mcst 31 1
255.255.255.255/32 perm 0 bcst 32 1

Routing table: __master.anon__.inet


Internet:
Destination Type RtRef Next hop Type Index NhRef Netif
default perm 0 rjct 526 1
0.0.0.0/32 perm 0 dscd 524 1
224.0.0.0/4 perm 0 mdsc 525 1
580

224.0.0.1/32 perm 0 224.0.0.1 mcst 521 1


255.255.255.255/32 perm 0 bcst 522 1

If a particular subnet has a route configured through the backup router and a static route under routing-
options, there could be problems accessing the fxp0 interface. In the example above, the issue with
accessing the fxp0 interface from the management device occurs when :

• The same route exists as a static route and through the backup router.

• There is a static route that is more specific than the route through the backup router.

In the examples, when the routes from the primary node are synchronized to the secondary node's
forwarding table, the route configured under static route takes precedence over the route under backup
router. If 0/0 is configured under backup-router, the chances of a better matching route under static
route is higher. Hence, we recommend avoiding 0/0 under backup router.

If you want to configure routes to the same destination using backup router as well as the static route,
split the routes when configuring under backup-router. This makes the routes configured under backup
router as the preferred routes and ensures that the fxp0 interface is accessible.

[edit routing-options static route]


0.0.0.0/0 next-hop 100.200.200.254;

[edit groups node0 ]


backup-router 192.168.1.254 destination [0.0.0.0/1 128.0.0.0/1];

Unable to Upgrade a Chassis Cluster Using In-Service Software Upgrade

IN THIS SECTION

Problem | 581

Cause | 581

Solution | 582
581

Problem

Description

Unable to upgrade a chassis cluster using minimal downtime upgrade method.

Environment

SRX5400 chassis cluster.

Symptoms

• Cluster stuck in node0 RG1 with IF flag and cannot upgarde.

• Configuration commit error is shown on CLI.

Cause

Configuration has same prefix on backup-router destinations (on backup RE/node) and user interface
address.

regress@R1_re# show interfaces ge-0/0/0

unit 0 {
family inet {
address 192.1.1.1/24;
}
}

regress@R1_re# show groups re1 system backup-router

10.204.63.254 destination 192.1.1.1/18;

regress@R1_re# commit

re0:
configuration check succeeds
re1:
error: Cannot have same prefix for backup-router destination and interface address. ge-0/0/0.0
inet 192.1.1
error: configuration check-out failed
582

re0:
error: remote commit-configuration failed on re1

Solution

In chassis cluster mode, the backup router's destination address for IPv4 and IPv6 routers using the
commands edit system backup-router address destination destination-address and edit system inet6-
backup-router address destination destination-address must not be same as interface address
configured for IPv4 and IPv6 using the commands edit interfaces interface-name unit logical-unit-
number family inet address ipv4-address and edit interfaces interface-name unit logical-unit-number
family inet6 address ipv6-address.

Configuring backup-router Command on Chassis Cluster

SUMMARY IN THIS SECTION

How to back up a router in an SRX Series chassis Problem | 582


cluster using the backup-router configuration Cause | 582
command.
Solution | 583

Problem

Description

Intermittent connectivity issues to NSM and other management hosts from the secondary node.

Environment

SRX Series chassis cluster

Cause

Setting a destination of 0.0.0.0/0 on the backup router (without configuration) is not supported.
583

Example of an incorrect configuration:

set groups node0 system backup-router 10.10.10.1 destination 0.0.0.0/0

Solution

See Configuring a Backup Router for the recommended way to set up a backup router by using a non-
zero prefix.

Example of a non-zero subnet backup-router configuration:

set groups node0 system backup-router 10.10.10.1 destination 10.100.0.0/16

As an alternative to the 0/0 backup-router destination, here is another example where 0/0 gets split
into two prefixes:

set groups node0 system backup-router 10.10.10.1 destination 0.0.0.0/1


set groups node0 system backup-router 10.10.10.1 destination 128.0.0.0/1

NOTE: If multiple networks need to be reachable through the backup router, you can add
multiple destination entries to the configuration. The backup-router configuration is used only by
the RG0 secondary node. The primary node continues to use the inet.0 route table.

Unable to Upgrade a Chassis Cluster Using In-Service Software Upgrade

IN THIS SECTION

Problem | 584

Cause | 584

Solution | 585
584

Problem

Description

Unable to upgrade a chassis cluster using minimal downtime upgrade method.

Environment

SRX5400 chassis cluster.

Symptoms

• Cluster stuck in node0 RG1 with IF flag and cannot upgarde.

• Configuration commit error is shown on CLI.

Cause

Configuration has same prefix on backup-router destinations (on backup RE/node) and user interface
address.

regress@R1_re# show interfaces ge-0/0/0

unit 0 {
family inet {
address 192.1.1.1/24;
}
}

regress@R1_re# show groups re1 system backup-router

10.204.63.254 destination 192.1.1.1/18;

regress@R1_re# commit

re0:
configuration check succeeds
re1:
error: Cannot have same prefix for backup-router destination and interface address. ge-0/0/0.0
inet 192.1.1
error: configuration check-out failed
585

re0:
error: remote commit-configuration failed on re1

Solution

In chassis cluster mode, the backup router's destination address for IPv4 and IPv6 routers using the
commands edit system backup-router address destination destination-address and edit system inet6-
backup-router address destination destination-address must not be same as interface address
configured for IPv4 and IPv6 using the commands edit interfaces interface-name unit logical-unit-
number family inet address ipv4-address and edit interfaces interface-name unit logical-unit-number
family inet6 address ipv6-address.

Data Collection for Customer Support

Before you contact customer support, collect the data listed in Table 39 on page 585.

Table 39: Data Collection for Customer Support

Background information

• All SSH or Telnet session captures

• Any available topology information

• Summary of how the device is being used (such as production, lab system, colocation)

• Summary of device history (new installation, production for x months or years, other recent cases)

• Summary of any recent changes in the network or on the device

Request support information (RSI)

Collect the RSI:

request support information | save /var/tmp/rsi-CURRENT DATE.log

Logs
586

Archive the contents of the /var/log/ folder:

file archive compress source /var/log/* destination /var/tmp/logs-CURRENT-DATE.tgz

Ensure that the /var/log/ directory is archived properly by verifying the file size using the file list /var/tmp/
logs-CURRENT-DATE.tgz detail command.

NOTE: Upload all the logs to the JTAC support case. For instructions on how to upload the logs,
see KB23337.
7 CHAPTER

Configuration Statements

aggregated-devices | 590

apply-groups (Chassis Cluster) | 592

arp-detect | 594

arp-throttle | 596

authentication-key | 598

authentication-type | 600

cak | 602

ckn | 604

cluster (Chassis) | 606

configuration-synchronize (Chassis Cluster) | 610

connectivity-association | 612

connectivity-association (MACsec Interfaces) | 614

control-link-recovery | 616

control-ports | 617

exclude-protocol | 619

fabric-options | 621

gigether-options (Chassis Cluster) | 624

global-threshold | 626

global-weight | 628

gratuitous-arp-count | 630
heartbeat-interval | 632

heartbeat-threshold | 634

hold-down-interval | 636

include-sci | 637

interface (Chassis Cluster) | 639

interfaces (MACsec) | 641

interface-monitor | 643

internal (Security IPsec) | 645

ip-monitoring | 647

key-server-priority (MACsec) | 650

lacp (Interfaces) | 652

link-protection (Chassis Cluster) | 654

macsec | 656

mka | 659

network-management | 661

no-encryption (MACsec) | 663

node (Chassis Cluster Redundancy Group) | 665

ntp | 667

ntp threshold | 675

offset | 677

preempt (Chassis Cluster) | 679

pre-shared-key | 682

priority (Protocols VRRP) | 684

redundancy-group (Chassis Cluster) | 686

redundant-ether-options | 689

redundant-parent (Interfaces) | 692

redundant-pseudo-interface-options | 693

replay-protect | 695

replay-window-size | 697

resource-watch | 699

reth-count (Chassis Cluster) | 702

retry-count (Chassis Cluster) | 704

retry-interval (Chassis Cluster) | 706

route-active-on | 708
scb-control-ports | 709

security-mode | 711

traceoptions (Chassis Cluster) | 713

transmit-interval (MACsec) | 716

use-active-child-mac-on-reth | 718

use-actual-mac-on-physical-interfaces | 719

virtual-address | 720

vrrp-group | 722

weight | 726
590

aggregated-devices

IN THIS SECTION

Syntax | 590

Hierarchy Level | 591

Description | 591

Options | 591

Required Privilege Level | 591

Release Information | 592

Syntax

aggregated-devices {
ethernet {
device-count number;
lacp {
link-protection {
non-revertive;
}
system-priority;
}
}
sonet {
device-count number;
}
maximum-links maximum-links-limit;
}
591

Hierarchy Level

[edit chassis]

Description

Configure properties for aggregated devices on the router. Aggregate Ethernet links are logical
interfaces defined on the device that bundle together multiple physical interfaces into a single interface
for the use of redundancy and bandwidth aggregation. When interconnecting devices you can create
aggregate ethernet interfaces to bundle together multiple physical ethernet links to increase bandwidth
and redundancy between devices.

Link aggregation enables you to group Ethernet interfaces to form a single link layer interface. Link
Aggregation Control Protocol (LACP) is supported in chassis cluster deployments, where aggregated
Ethernet interfaces and redundant Ethernet interfaces are supported simultaneously.

You must first configure the system to enable configuring the Aggregated Ethernet (ae) Interfaces. By
default, Juniper devices do not have any aggregated ethernet interfaces created. To configure the device
to support a given number of ae interfaces, you must define it on a per chassis basis using the set chassis
aggregated-devices devices {1-32} in configuration mode. The number of devices you define will be the
number of aggregated ethernet interfaces that the system will create which can be configured just like
any other ethernet interface. Also you can view the interfaces created by using the show interface terse
command. Once you have defined the number of aggregated ethernet devices on the chassis you can
then continue to configure the LAG members on a per ethernet interface basis.

Options

The remaining statements are explained separately.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


592

Release Information

Statement introduced before Junos OS Release 7.4.

Support for LACP link protection and system priority introduced in Junos OS Release 9.3.

RELATED DOCUMENTATION

Configuring Junos OS for Supporting Aggregated Devices

apply-groups (Chassis Cluster)

IN THIS SECTION

Syntax | 592

Hierarchy Level | 592

Description | 593

Options | 593

Required Privilege Level | 593

Release Information | 593

Syntax

apply-groups [$node]

Hierarchy Level

[edit chassis cluster]


593

Description

Apply node-specific parameters to each node in a chassis cluster.

You can use the [edit groups] option to create a unique configuration between the cluster members by
defining a unique hostname for each node and assigning a unique IP address for the fxp0 interface on
each node.

Each group is named after the node it is applied to (node 0 and node 1) and once you apply the
configured groups using the apply-groups statement, only the group that matches the node name is
applied.

The configuration you specified under group node 0 will be active only on node 0 and the configuration
you specified under group node 1 will be active only on node 1.

Options

${node} Each node (node0 or node1) in a chassis cluster.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

cluster (Chassis) | 606


594

arp-detect

IN THIS SECTION

Syntax | 594

Hierarchy Level | 594

Description | 594

Options | 595

Required Privilege Level | 595

Release Information | 595

Syntax

arp-detect milliseconds;

Hierarchy Level

[edit forwarding-options next-hop]

Description

Define the length of time (in milliseconds) for an SPU to wait for an acknowledgement from the Routing
Engine that an ARP request has been received from the SPU. If the Routing Engine fails to respond
within the specific time interval, the SPU considers that the Routing Engine CPU utilization is high at
that moment, and initiates the ARP throttling. ARP throttling is initiated on the logical interface, where
the incoming packet had triggered the ARP request.
595

Configuring a shorter ARP detect time interval results in triggering of ARP throttling more frequently.
Frequent ARP throttling is useful for lowering Routing Engine CPU utilization caused by excessive ARP
requests.

For example, when you configure the set forwarding-options nexthop arp-detect 300 option, the nexthop
resolution request must be acknowledged by the Routing Engine within 300 milliseconds. If the SPU
does not get an acknowledgment from the Routing Engine in 300 milliseconds, the logical interface
which had received the packet that triggered the nexthop request, changes into ARP throttle state.
While the ARP throttle state is active for that interface, traffic entering into that interface does not
trigger new nexthop resolution requests.

CAUTION: We recommend that only advanced Junos OS users attempt to configure


ARP throttle and ARP detect feature. Because, improper configuration might result in
high CPU utilization of Routing Engine affecting other processes on your device.

Options

milliseconds—Number of seconds the SPU waits before receiving a response from Routing Engine.

• Range: 1 through 10000 milliseconds

• Default: 10000 milliseconds

Required Privilege Level

security—To view this statement in the configuration.

security-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 12.3X48-D65 and Junos OS Release 15.1X49-D130.

RELATED DOCUMENTATION

arp-throttle | 596
596

arp-throttle

IN THIS SECTION

Syntax | 596

Hierarchy Level | 596

Description | 596

Options | 597

Required Privilege Level | 597

Release Information | 597

Syntax

arp-throttle seconds;

Hierarchy Level

[edit forwarding-options next-hop]

Description

Define the time duration (in seconds) for Address Resolution Protocol (ARP) request throttling to remain
active when it is triggered.

When ARP throttling is triggered, it is active for a given logical interface. For the configured duration of
time, the ARP throttling remains active, and the traffic entering into the specific interface does not
trigger ARP nexthop resolution requests, which are being sent to the Routing Engine from the specific
SPU.
597

When you configure a longer time duration, the ARP throttling can protect the Routing Engine by
preventing too many ARP requests being triggered by incoming traffic.

For example, if there is a large amount of traffic destined to a directly connected, unresolved IP address,
chances of getting frequent ARP requests is very high, which eventually results into a high CPU load on
the Routing Engine. By setting a longer time interval of the ARP throttle, the Routing Engine is protected
from numerous ARP requests.

For example, when you configure the set forwarding-options nexthop arp-throttle 15 option, and the
interface state changes to throttle state, the nexthop requests triggered by incoming traffic into this
interface, will not be sent. After 15 seconds, interface changes back from throttle to normal state. Then
the nexthop requests triggered by the incoming traffic into this interface are sent to the Routing Engine
again.

Options

seconds—Time interval (in seconds) for Address Resolution Protocol (ARP) request throttling to remain
active when it is triggered.

• Range: 10 through 100 seconds

• Default: 10 seconds

Required Privilege Level

security—To view this statement in the configuration.

security-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 12.3X48-D65, Junos OS Release 15.1X49-D60, and Junos
OS Release 15.1X49-D130.

RELATED DOCUMENTATION

arp-detect | 594
598

authentication-key

IN THIS SECTION

Syntax | 598

Hierarchy Level | 598

Description | 598

Options | 599

Required Privilege Level | 599

Release Information | 599

Syntax

authentication-key key;

Hierarchy Level

[edit interfaces interface-name unit logical-unit-number family inet address address vrrp-
group group-id],
[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number
family inet address address vrrp-group group-id]

Description

Configure a Virtual Router Redundancy Protocol (VRRP) IPv4 authentication key. You also must specify a
VRRP authentication scheme by including the authentication-type statement.

All devices in the VRRP group must use the same authentication scheme and password.
599

NOTE: When VRRPv3 is enabled, the authentication-type and authentication-key statements cannot
be configured for any VRRP groups.

Options

key—Authentication password. For simple authentication, it can be 1 through 8 characters long. For
Message Digest 5 (MD5) authentication, it can be 1 through 16 characters long. If you include spaces,
enclose all characters in quotation marks (“ ”).

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced before Junos OS Release 7.4.

RELATED DOCUMENTATION

Configuring VRRP Authentication (IPv4 Only)


authentication-type
version-3
Understanding VRRP on SRX Series Firewalls | 329
Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant Ethernet Interfaces | 335
600

authentication-type

IN THIS SECTION

Syntax | 600

Hierarchy Level | 600

Description | 600

Options | 601

Required Privilege Level | 601

Release Information | 601

Syntax

authentication-type (md5 | simple);

Hierarchy Level

[edit interfaces interface-name unit logical-unit-number family inet address address vrrp-
group group-id],
[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number
family inet address address vrrp-group group-id]

Description

Enable Virtual Router Redundancy Protocol (VRRP) IPv4 authentication and specify the authentication
scheme for the VRRP group. If you enable authentication, you must specify a password by including the
authentication-key statement. The specific type of authentication used by OSPF is encoded in this field.

All devices in the VRRP group must use the same authentication scheme and password.
601

NOTE: When VRRPv3 is enabled, the authentication-type and authentication-key statements cannot
be configured for any VRRP groups.

Options

authentication Authentication scheme:

• simple Use a simple password. The password is included in the transmitted packet, so this method
of authentication is relatively insecure.

• md5 Use the MD5 algorithm to create an encoded checksum of the packet. The encoded checksum
is included in the transmitted packet. The receiving routing platform uses the authentication
key to verify the packet, discarding it if the digest does not match. This algorithm provides a
more secure authentication scheme.

• Default: none (no authentication is performed).

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced before Junos OS Release 7.4.

RELATED DOCUMENTATION

Configuring VRRP Authentication (IPv4 Only)


authentication-key
602

version-3
Understanding VRRP on SRX Series Firewalls | 329
Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant Ethernet Interfaces | 335

cak

IN THIS SECTION

Syntax | 602

Hierarchy Level | 602

Description | 603

Default | 603

Options | 603

Required Privilege Level | 603

Release Information | 603

Syntax

ckn hexadecimal-number;

Hierarchy Level

[edit security macsec connectivity-association pre-shared-key]


603

Description

Specifies the connectivity association key (CAK) for a pre-shared key.

To configure MACsec on the supported ports, you need to create the preshared key by configuring the
connectivity association key name (CKN) and connectivity association key (CAK).

A preshared key is exchanged between directly-connected links to establish a MACsec-secure link. The
CKN is a 64-digit hexadecimal number and the CAK is a 32-digit hexadecimal number. The CKN and the
CAK must match on both ends of a link to create a MACsec-secured link.

Default

No CAK exists, by default.

Options

hexadecimal- The key name, in hexadecimal format.


number
The key name is 32 hexadecimal characters in length. If you enter a key name that is
less than 32 characters long, the remaining characters are set to 0.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.


604

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

ckn

IN THIS SECTION

Syntax | 604

Hierarchy Level | 604

Description | 605

Default | 605

Options | 605

Required Privilege Level | 605

Release Information | 605

Syntax

ckn hexadecimal-number;

Hierarchy Level

[edit security macsec connectivity-association pre-shared-key]


605

Description

Specifies the connectivity association key name (CKN) for a pre-shared key.

To configure MACsec on supported ports, you need to create the preshared key by configuring the
connectivity association key name (CKN) and connectivity association key (CAK).

A preshared key is exchanged between directly-connected links to establish a MACsec-secure link. The
CKN is a 64-digit hexadecimal number and the CAK is a 32-digit hexadecimal number. The CKN and the
CAK must match on both ends of a link to create a MACsec-secured link.

Default

No CKN exists, by default.

Options

hexadecimal- The key name, in hexadecimal format.


number
The key name is 32 hexadecimal characters in length. If you enter a key name that is
less than 32 characters long, the remaining characters are set to 0.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.


606

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

cluster (Chassis)

IN THIS SECTION

Syntax | 606

Hierarchy Level | 608

Description | 608

Options | 608

Required Privilege Level | 610

Release Information | 610

Syntax

cluster {
configuration-synchronize (Chassis Cluster) {
no-secondary-bootup-auto;
}
control-interface {
node name {
disable;
}
}
control-link-recovery;
control-ports fpc {
port;
}
health-monitoring;
607

heartbeat-interval milliseconds;
heartbeat-threshold heartbeat-threshold;
network-management {
cluster-master;
}
redundancy-group (Chassis Cluster) name {
gratuitous-arp-count gratuitous-arp-count;
hold-down-interval seconds;
interface-monitor name {
weight weight;
}
ip-monitoring {
family {
inet {
address name {
interface logical-interface-name {
secondary-ip-address;
}
weight weight;
}
}
}
global-threshold global-threshold;
global-weight global-weight;
retry-count retry-count;
retry-interval (Chassis Cluster) retry-interval;
}
node (Chassis Cluster Redundancy Group) (0 | 1) {
priority priority;
}
preempt (Chassis Cluster) {
delay seconds;
limit limit;
period seconds;
}
}
redundant-interface name {
mapping-interface mapping-interface;
}
reth-count (Chassis Cluster) reth-count;
traceoptions (Chassis Cluster) {
file <filename> <files files> <match match> <size size> <(world-readable | no-world-
readable)>;
608

flag name;
level (alert | all | critical | debug | emergency | error | info | notice | warning);
no-remote-trace;
}
}

Hierarchy Level

[edit chassis]

Description

Configure a chassis cluster. Perform the configuration under the [edit chassis cluster] configuration
stanza to define chassis cluster configuration, operations, and monitoring. This configuration must
specify configuration synchronization, control link recovery, heartbeat interval and threshold, network
management, redundancy group, and traceoptions.

Options

configuration- Disable automatic chassis cluster synchronization. See "configuration-synchronize


synchronize (Chassis Cluster)" on page 610.

control-interface Disable and Enable chassis cluster control-link interface on SRX1500, SRX4100,
SRX4200, and SRX4600 devices. If you want to reboot any of the nodes, then you
must disable the control interfaces on both nodes using the CLI configuration to
ensure control link remains disabled after reboot. When control link is down,
configuration change on local node will not be synchronized to the remote node.

From configuration mode, run the set chassis cluster control-interface <node0/node1>
disable on node 0 or node 1 to disable the control link and to enable the control
link run the delete chassis cluster control-interface <node0/node1> disable on both the
nodes. If you have disabled the links using the configuration command, then the
links will remain disabled even after system reboot.
609

From the operational mode, run the request chassis cluster control-interface <node0/
node1> disable or the request chassis cluster control-interface <node0/node1> enable
commands to enable or disable the control link from the local node. If you have
disabled control link using the operational mode CLI commands, the links will be
enabled after system reboot.

control-link- Enable automatic control link recovery option.


recovery
control-ports Enable specific chassis cluster control ports.

• Values:

• fpc—FPC slot number

• port—Port number

health-monitoring Enable to monitor the health status of the SRX Series devices operating in chassis
cluster mode. The health status between the two nodes is monitored and shared
over control links and fabric links. Failover between the nodes occurs based on the
heart beat status and health status of the control links and fabric links. By default,
the option is disabled.

heartbeat-interval Interval between successive heartbeats (milliseconds)

• Default: 1000

• Range: 1000-2000

heartbeat- Number of consecutive missed heartbeats to indicate device failure


threshold
• Default: 3

• Range: 3-8

network- Define parameters for network management. See "network-management" on page


management 661.

redundancy-group Define a redundancy group. See "redundancy-group (Chassis Cluster)" on page


name 686.

reth-count Number of redundant ethernet interfaces

• Range: 1-128

traceoptions Define chassis cluster redundancy process tracing operations. See "traceoptions
(Chassis Cluster)" on page 713.
610

The remaining statements are explained separately. See CLI Explorer.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.0.

The health-monitoring option is introduced in Junos OS Release 18.4R1.

The control-interface option is introduced in Junos OS Release 20.4R1 for SRX1500 devices.

RELATED DOCUMENTATION

ip-monitoring | 647

configuration-synchronize (Chassis Cluster)

IN THIS SECTION

Syntax | 611

Hierarchy Level | 611

Description | 611

Options | 611

Required Privilege Level | 611

Release Information | 612


611

Syntax

configuration-synchronize {
no-secondary-bootup-auto;
}

Hierarchy Level

{primary:node0}
[edit chassis cluster]

Description

Disables the automatic chassis cluster synchronization between the primary and secondary nodes.

The chassis cluster synchronization feature automatically synchronizes the configuration from the
primary node to the secondary node when the secondary joins the primary as a cluster. If you want to
disable automatic chassis cluster synchronization between the primary and secondary nodes, you can do
so by entering the set chassis cluster configuration-synchronize no-secondary-bootup-auto command in
configuration mode.

Options

no-secondary-bootup-auto Disable the automatic chassis cluster synchronization between the primary
and secondary nodes.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


612

Release Information

Statement introduced in Junos OS Release 12.1X47-D10.

RELATED DOCUMENTATION

Understanding Automatic Chassis Cluster Synchronization Between Primary and Secondary Nodes |
151
request chassis cluster configuration-synchronize | 745
show chassis cluster information configuration-synchronization | 803

connectivity-association

IN THIS SECTION

Syntax | 612

Hierarchy Level | 613

Description | 613

Required Privilege Level | 613

Release Information | 613

Syntax

connectivity-association connectivity-association-name;
exclude-protocol protocol-name;
include-sci;
mka {
must-secure;
key-server-priority priority-number;
transmit-interval interval;
}
no-encryption;
613

offset (0|30|50);
pre-shared-key {
cak hexadecimal-number;
ckn hexadecimal-number;
}
replay-protect{
replay-window-size number-of-packets;
}
security-mode security-mode;
}

Hierarchy Level

[edit security macsec]

Description

Create or configure a MACsec connectivity association.

A connectivity association is not applying MACsec to traffic until it is associated with an interface.
MACsec connectivity associations are associated with interfaces using the interfaces statement in the
[edit security macsec] hierarchy.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.


614

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

connectivity-association (MACsec Interfaces)

IN THIS SECTION

Syntax | 614

Hierarchy Level | 614

Description | 615

Default | 615

Required Privilege Level | 615

Release Information | 615

Syntax

connectivity-association connectivity-association-name;

Hierarchy Level

[edit security macsec cluster-control-port <idx>]


[edit security macsec cluster-data-port interface]
615

Description

Applies a connectivity association to an interface, which enables Media Access Control Security
(MACsec) on that interface. The point-to-point links are secured after security keys are matched at the
endpoints of the links. If you enable MACsec by using the static connectivity association key (CAK)
security mode, user-configured, preshared keys are matched. If you enable MACsec by using the static
secure association key (SAK) security mode, user-configured static security association keys are
matched.

When you enable MACsec using static CAK, you have to create and configure a connectivity
association.

Default

No connectivity associations are associated with any interfaces.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656
616

control-link-recovery

IN THIS SECTION

Syntax | 616

Hierarchy Level | 616

Description | 616

Required Privilege Level | 617

Release Information | 617

Syntax

control-link-recovery;

Hierarchy Level

[edit chassis cluster]

Description

Enable control link recovery to be done automatically by the system.

If the control link fails, the secondary node enters a disabled state. To recover the node from the
disabled mode, you must reboot the node to resume operations. You can make this reboot automatic by
using the control-link-recovery configuration option.

After the control link recovers, the system checks whether it receives at least three consecutive
heartbeats on the control link. This is to ensure that the control link is not flapping and is perfectly
healthy. Once this criterion is met, the system issues an automatic reboot on the node that was disabled
617

when the control link failed. When the disabled node reboots, the node rejoins the cluster. There is no
need for any manual intervention.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.5.

RELATED DOCUMENTATION

interface (Chassis Cluster) | 639

control-ports

IN THIS SECTION

Syntax | 618

Hierarchy Level | 618

Description | 618

Options | 618

Required Privilege Level | 619

Release Information | 619


618

Syntax

control-ports fpc {
port;
}

Hierarchy Level

[edit chassis cluster]

Description

Enable the specific control port to use as a control link for the chassis cluster. By default, all control
ports are disabled.

After connecting the control ports, you need to configure the control ports to setup control links as a
step to establish the chassis cluster.

You need to configure a minimum of one control port per chassis of the cluster. If you configure port 0
only, the Juniper Services Redundancy Protocol process (jsrpd) does not send control heartbeats on
control link 1 and the counters it sends will show zeroes.

Options

• fpc slot-number —Flexible PIC Concentrator (FPC) slot number.

NOTE: FPC slot range depends on platform. The maximum range of 0 through 23 applies to
SRX5800 devices; for SRX5600 devices, the only applicable range is 0 through 11; for
SRX5400 devices, the applicable slot range is 0 through 5. See "Chassis Cluster Control Plane
Interfaces" on page 67 for details.

• port port-number —Port number on which to configure the control port.


619

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.2. Support.

RELATED DOCUMENTATION

cluster (Chassis) | 606

exclude-protocol

IN THIS SECTION

Syntax | 619

Hierarchy Level | 620

Description | 620

Default | 620

Options | 620

Required Privilege Level | 620

Release Information | 621

Syntax

exclude-protocol protocol-name;
620

Hierarchy Level

[edit security macsec connectivity-association]

Description

Specifies protocols whose packets are not secured using Media Access Control Security (MACsec) when
MACsec is enabled on a link using static connectivity association key (CAK) security mode.

When this option is enabled in a connectivity association that is attached to an interface, MACsec is not
enabled for all packets of the specified protocols that are sent and received on the link.

Default

Disabled.

All packets are secured on a link when MACsec is enabled, with the exception of all types of Spanning
Tree Protocol (STP) packets.

Options

protocol- Specifies the name of the protocol that should not be MACsec-secured. Options include:
name
• cdp —Cisco Discovery Protocol.

• lacp —Link Aggregation Control Protocol.

• lldp —Link Level Discovery Protocol.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.


621

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

fabric-options

IN THIS SECTION

Syntax | 621

Hierarchy Level | 622

Description | 622

Options | 623

Required Privilege Level | 623

Release Information | 623

Syntax

fabric-options {
member-interfaces member-interface-name;
}
622

Hierarchy Level

[edit interfaces interface-name]

Description

Configure fabric interface specific options in chassis clusters.

The fabric is the data link between the nodes and is used to forward traffic between the chassis. Each
node in the chassis requires a fabric interface configured. To create a fabric link between the two chassis
requires the creation of a special interface called the fab interface. Node 0’s fabric interface, called fab0,
and node 1’s fabric interface, called fab1.

Only the same type of interfaces can be configured as fabric children, and you must configure an equal
number of child links for fab0 and fab1.

You can enable and disable the fabric link on SRX1500, SRX4100, SRX4200, and SRX4600 devices.

From configuration mode,

run the set interfaces fab0 disable command to disable the fabric link interface fab0 and set interfaces fab1
disable command to disable the fabric link interface fab1.

run the delete interfaces fab0 disable to enable fabric link interface fab0 and delete interfaces fab1 disable
to enable fabric link interface fab1.

fab0 {
fabric-options {
member-interfaces {
ge-0/0/4;
}
}
}
fab1 {
fabric-options {
member-interfaces {
ge-2/0/4;
}
}
}
623

NOTE: When you run the system autoinstallation command, the command will configure unit 0
logical interface for all the active state physical interfaces. However, a few commands such as
fabric-options do not allow the physical interface to be configured with a logical interface. If the
system autoinstallation and the fabric-options commands are configured together, the following
message is displayed:

incompatible with 'system autoinstallation’

Options

member-interface-name—Member interface name.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 8.5.

RELATED DOCUMENTATION

Example: Configuring the Chassis Cluster Fabric Interfaces | 60


624

gigether-options (Chassis Cluster)

IN THIS SECTION

Syntax | 624

Hierarchy Level | 625

Description | 626

Options | 626

Required Privilege Level | 626

Release Information | 626

Syntax

gigether-options {
802.3ad {
backup | primary | bundle;
lacp {
port-priority priority;
}
}
auto-negotiation {
remote-fault {
local-interface-offline | local-interface-online;
}
}
no-auto-negotiation;
ethernet-switch-profile {
mac-learn-enable;
tag-protocol-id [tpids];
ethernet-policer-profile {
input-priority-map {
ieee802.1p {
premium [values];
}
}
625

output-priority-map {
classifier {
premium {
forwarding-class class-name {
loss-priority (high | low);
}
}
}
}
policer cos-policer-name {
aggregate {
bandwidth-limit bps;
burst-size-limit bytes;
}
premium {
bandwidth-limit bps;
burst-size-limit bytes;
}
}
}
}
flow-control | no-flow-control;
ieee-802-3az-eee;
ignore-l3-incompletes;
loopback | no-loopback;
mpls {
pop-all-labels {
required-depth (1 | 2);
}
}
redundant-parent (Interfaces Gigabit Ethernet) interface-name;
source-address-filter {
mac-address;
}
}

Hierarchy Level

[edit interfaces interface-name]


626

Description

Configure Gigabit Ethernet specific interface properties.

Options

The remaining statements are explained separately. See CLI Explorer.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.2.

RELATED DOCUMENTATION

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces | 103

global-threshold

IN THIS SECTION

Syntax | 627

Hierarchy Level | 627

Description | 627
627

Options | 627

Required Privilege Level | 628

Release Information | 628

Syntax

global-threshold number;

Hierarchy Level

[edit chassis cluster redundancy-groupgroup-number ip-monitoring ]

Description

Define global threshold for IP monitoring. This is the number that needs to be met or exceeded by all of
the cumulative weights of the monitored IP addresses to trigger a failover.

When a monitored address is marked as unreachable, the weight value associated with that address is
deducted from the the redundancy group IP address monitoring global threshold. If the accumulated
monitored address weight values surpass the global-threshold value, that is, when the global threshold
reaches 0, the global weight is deducted from the redundancy group threshold. Every redundancy group
has a default threshold of 255. If the threshold reaches 0, a failover is triggered

Options

number—Value at which the IP monitoring weight is applied against the redundancy group failover
threshold.

• Range: 0 through 255


628

• Default: 255

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.1.

RELATED DOCUMENTATION

ip-monitoring | 647

global-weight

IN THIS SECTION

Syntax | 629

Hierarchy Level | 629

Description | 629

Options | 629

Required Privilege Level | 630

Release Information | 630


629

Syntax

global-weight number;

Hierarchy Level

[edit chassis cluster redundancy-groupgroup-numberip-monitoring]

Description

Define global weight for IP monitoring. This is the weight that is subtracted from the redundancy group
weight for all of the hosts being monitored. This number specifies the relative importance of IP address
monitored objects in the operation of the redundancy group.

Every monitored IP address is assigned a weight. If the monitored address becomes unreachable, the
weight of the object is deducted from the global-threshold of IP monitoring objects in its redundancy
group. When the global-threshold reaches 0, the global-weight is deducted from the redundancy group.
Every redundancy group has a default threshold of 255. If the threshold reaches 0, a failover is triggered.
Failover is triggered even if the redundancy group is in manual failover mode and preemption is not
enabled.

Options

number —Combined weight assigned to all monitored IP addresses. A higher weight value indicates a
greater importance.

• Range: 0 through 255

• Default: 255
630

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.1.

RELATED DOCUMENTATION

ip-monitoring | 647

gratuitous-arp-count

IN THIS SECTION

Syntax | 630

Hierarchy Level | 631

Description | 631

Options | 631

Required Privilege Level | 631

Release Information | 631

Syntax

gratuitous-arp-count number;
631

Hierarchy Level

[edit chassis cluster redundancy-group group-number]

Description

Specify the number of gratuitous Address Resolution Protocol (ARP) requests to send on an active
interface after failover.

You can configure this option to specify the number of gratuitous ARP requests that an interface can
send to notify other network devices of its presence after the redundancy group it belongs to has failed
over.

By default, the SRX Series Firewall sends four GARPs per reth on a failover. You can modify the number
of GARPs sent per-redundancy-group basis.

Options

number—Number of gratuitous ARP requests that a newly elected primary device in a chassis cluster
sends out to announce its presence to the other network devices.

• Range: 1 through 16

• Default: 4

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.0.


632

RELATED DOCUMENTATION

redundancy-group (Chassis Cluster) | 686

heartbeat-interval

IN THIS SECTION

Syntax | 632

Hierarchy Level | 632

Description | 632

Options | 633

Required Privilege Level | 633

Release Information | 633

Syntax

heartbeat-interval milliseconds;

Hierarchy Level

[edit chassis cluster]

Description

Set the interval between the periodic signals broadcast to the devices in a chassis cluster to indicate that
the active node is operational.
633

The heartbeat-interval option works in combination with the heartbeat-threshold option to define the wait
time before failover is triggered in a chassis cluster. The default values of these options produce a wait
time of 3 seconds. In a large configuration approaching full capacity on an SRX5400 or SRX5600 or
SRX5800 device, however, we recommend that you increase the failover wait time to 5 seconds.

For example, a heartbeat-threshold of 3 and a heartbeat-interval of 1000 milliseconds result in a total wait of
3 seconds before failover is triggered. To increase this wait to 5 seconds, you could increase the
heartbeat-threshold, the heartbeat-interval, or both. A heartbeat-threshold of 5 and a heartbeat-interval of 1000
milliseconds would yield a wait time of 5 seconds. Setting the heartbeat-threshold to 4 and the heartbeat-
interval to 1250 milliseconds would also yield a wait time of 5 seconds.

NOTE: In a chassis cluster scaling environment, the heartbeat-threshold must always be set to 8.

Options

milliseconds—Time interval between any two heartbeat messages.

• Range: 1000 through 2000 milliseconds

• Default: 1000 milliseconds

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9. Statement updated in Junos OS Release 10.4.

RELATED DOCUMENTATION

cluster (Chassis) | 606


634

heartbeat-threshold

IN THIS SECTION

Syntax | 634

Hierarchy Level | 634

Description | 634

Options | 635

Required Privilege Level | 635

Release Information | 635

Syntax

heartbeat-threshold number;

Hierarchy Level

[edit chassis cluster]

Description

Set the number of consecutive missed heartbeat signals that a device in a chassis cluster must exceed to
trigger failover of the active node.

The heartbeat-threshold option works in combination with the heartbeat-interval option to define the wait
time before failover is triggered in a chassis cluster. The default values of these options produce a wait
time of 3 seconds. In a large configuration approaching full capacity on an SRX5400 or SRX5600 or
SRX5800 device, however, we recommend that you increase the failover wait time to 5 seconds.
635

For example, a heartbeat-threshold of 3 and a heartbeat-interval of 1000 milliseconds result in a total wait of
3 seconds before failover is triggered. To increase this wait to 5 seconds, you could increase the
heartbeat-threshold, the heartbeat-interval, or both. A heartbeat-threshold of 5 and a heartbeat-interval of 1000
milliseconds would yield a wait time of 5 seconds. Setting the heartbeat-threshold to 4 and the heartbeat-
interval to 1250 milliseconds would also yield a wait time of 5 seconds.

Options

number—Number of consecutive missed heartbeats.

• Range: 3 through 8

• Default: 3

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.0. Statement updated in Junos OS Release 10.4.

RELATED DOCUMENTATION

cluster (Chassis) | 606


636

hold-down-interval

IN THIS SECTION

Syntax | 636

Hierarchy Level | 636

Description | 636

Options | 637

Required Privilege Level | 637

Release Information | 637

Syntax

hold-down-interval number;

Hierarchy Level

[edit chassis cluster redundancy-group group-number]

Description

Set the minimum interval to be allowed between back-to-back failovers for the specified redundancy
group (affects manual failovers, as well as automatic failovers associated with monitoring failures).

For redundancy group 0, this setting prevents back-to-back failovers from occurring less than 5 minutes
(300 seconds) apart. Note that a redundancy group 0 failover implies a Routing Engine failure.

For some configurations, such as ones with a large number of routes or logical interfaces, the default or
specified interval for redundancy group 0 might not be sufficient. In such cases, the system
637

automatically extends the dampening time in increments of 60 seconds until the system is ready for
failover.

Options

number—Number of seconds specified for the interval.

• Range: For redundancy group 0, 300 through 1800 seconds; for redundancy group 1 through 128, 0
through 1800 seconds.

• Default: For redundancy group 0, 300 seconds; for redundancy group 1 through 128, 1 second.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.0.

RELATED DOCUMENTATION

cluster (Chassis) | 606

include-sci

IN THIS SECTION

Syntax | 638
638

Hierarchy Level | 638

Description | 638

Default | 639

Required Privilege Level | 639

Release Information | 639

Syntax

include-sci;

Hierarchy Level

[edit security macsec connectivity-association]

Description

Specify that the SCI tag be appended to each packet on a link that has enabled MACsec.

You must enable SCI tagging on a switch that is enabling MACsec on an Ethernet link connecting to an
SRX device.

SCI tags are automatically appended to packets leaving a MACsec-enabled interface on an SRX device.
This option is, therefore, not available on an SRX device.

You should only use this option when connecting a switch to an SRX device, or to a host device that
requires SCI tagging. SCI tags are eight octets long, so appending an SCI tag to all traffic on the link adds
a significant amount of unneeded overhead.
639

Default

SCI tagging is enabled on an SRX Series Firewall that have enabled MACsec using static connectivity
association key (CAK) security mode, by default.

SCI tagging is disabled on all other interfaces, by default.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

interface (Chassis Cluster)

IN THIS SECTION

Syntax | 640

Hierarchy Level | 640

Description | 640

Options | 640
640

Required Privilege Level | 641

Release Information | 641

Syntax

logical-interface-name secondary-ip-address;

Hierarchy Level

[edit chassis cluster redundancy-groupgroup-number ip-monitoring family family-name IP–


address]

Description

Specify the redundant Ethernet interface, including its logical-unit-number, through which the
monitored IP address must be reachable. The specified redundant Ethernet interface can be in any
redundancy group. Likewise specify a secondary IP address to be used as a ping source for monitoring
the IP address through the secondary node’s redundant Ethernet interface link.

Options

• logical-interface-name—Redundant Ethernet interface through which the monitored IP address must be


reachable. You must specify the redundant Ethernet interface logical-unit-number. Note that you
must also configure a secondary ping source IP address (see below).

• Range: reth0.logical-unit-number through reth128.logical-unit-number (device dependent)


641

NOTE: If the redundant Ethernet interface belongs to a VPN routing and forwarding (VRF)
routing instance type, then the IP monitoring feature will not work.

• secondary-ip-address IP–address—Specify the IP address that are used as the source IP address of ping
packets for IP monitoring from the secondary child link of the redundant Ethernet interface. An IP
address for sourcing the ping packets on the primary link of the redundant Ethernet interface must
be configured before you can configure secondary-ip-address. For legacy support reasons, monitoring
on an IP address without identifying a redundant Ethernet interface and without configuring a
secondary ping source IP address is permitted but not recommended.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.1.

RELATED DOCUMENTATION

cluster (Chassis) | 606

interfaces (MACsec)

IN THIS SECTION

Syntax | 642

Hierarchy Level | 642


642

Description | 642

Required Privilege Level | 642

Release Information | 643

Syntax

interface-name {
connectivity-association connectivity-association-name;
}

Hierarchy Level

[edit security macsec cluster-data-port]

Description

Specify chassis cluster fabric interface on which MACsec is enabled. For SRX340, and SRX345 devices,
the fabric interface can be any 1 G Ethernet interface. Use this configuration to apply a connectivity
association to an interface, which enables Media Access Control Security (MACsec) on that interface.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.


643

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

interface-monitor

IN THIS SECTION

Syntax | 643

Hierarchy Level | 644

Description | 644

Options | 644

Required Privilege Level | 644

Release Information | 645

Syntax

interface-monitor interface-name {
weight number;
}
644

Hierarchy Level

[edit chassis cluster redundancy-group group-number ]

Description

Specify a redundancy group interface to be monitored for failover and the relative weight of the
interface.

For a redundancy group to automatically failover to another node, its interfaces must be monitored.
Interface monitoring monitors the physical status of an interface.

When you configure a redundancy group, you can specify a set of interfaces that the redundancy group
is to monitor for status (or “health”) of interface to determine whether the interface is up or down. A
monitored interface can be a child interface of any of its redundant Ethernet interfaces.

When you configure an interface for a redundancy group to monitor, you assign a weight to the
interface. Every redundancy group has a threshold tolerance value initially set to 255. When an interface
monitored by a redundancy group becomes unavailable, its weight is subtracted from the redundancy
group's threshold. When a redundancy group's threshold reaches 0, the redundancy group fails over to
the other node in the cluster.

Options

name Name of the interface to monitor

weight Weight assigned to this interface that influences failover

• Range: 0-255

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


645

Release Information

Statement introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

cluster (Chassis) | 606

internal (Security IPsec)

IN THIS SECTION

Syntax | 645

Hierarchy Level | 646

Description | 646

Options | 646

Required Privilege Level | 647

Release Information | 647

Syntax

internal {
security-association {
manual {
encryption {
algorithm (3des-cbc | aes-128-cbc);
ike-ha-link-encryption enable;
key ascii-text;
}
}
646

}
}

Hierarchy Level

[edit security ipsec]

Description

Enable secure login and to prevent attackers from gaining privileged access through this control port by
configuring the internal IP security (IPsec) security association (SA).

When the internal IPsec is configured, IPsec-based rlogin and remote command (rcmd) are enforced, so an
attacker cannot gain unauthorized information.

Options

security- Specify an IPsec SA. An SA is a simplex connection that allows two hosts to
association communicate with each other securely by means of IPsec.

manual encryption Specify a manual SA. Manual SAs require no negotiation; all values, including the
keys, are static and specified in the configuration.

algorithm 3des-cbc Specify the encryption algorithm for the internal Routing-Engine-to-Routing-
Engine IPsec SA configuration.

algorithm aes-128- Specify the encryption algorithm for high availability encryption link.
cbc
iked-ha-link- Enable encryption for internal messages.
encryption
• Values:

• enable—Enable HA link encryption IKE internal messages


647

key ascii-text Specify the encryption key. You must ensure that the manual encryption key is in
ASCII text and 24 characters long; otherwise, the configuration will result in a
commit failure.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 12.1X45-D10.

Support for ike-ha-link-encryption option added in Junos OS Release 12.1X47-D15.

Support for iked_encryption option added in Junos OS Release 12.1X47-D10.

Support for aes-128-cbc option added in Junos OS Release 19.1R1.

Support for ike-ha-link-encryption option added for vSRX Virtual Firewall in Junos OS Release 19.4R1

RELATED DOCUMENTATION

Example: Configuring an Active/Passive Chassis Cluster on SRX5800 Firewalls | 369


show security internal-security-association | 977

ip-monitoring

IN THIS SECTION

Syntax | 648

Hierarchy Level | 648


648

Description | 649

Options | 649

Required Privilege Level | 650

Release Information | 650

Syntax

ip-monitoring {
family {
inet {
ipv4-address {
interface {
logical-interface-name;
secondary-ip-address ip-address;
}
weight number;
}
}
}
global-threshold number;
global-weight number;
retry-count number;
retry-interval seconds;
}

Hierarchy Level

[edit chassis cluster redundancy-group group-number]


649

Description

Specify a global IP address monitoring threshold and weight, and the interval between pings (retry-
interval) and the number of consecutive ping failures (retry-count) permitted before an IP address is
considered unreachable for all IP addresses monitored by the redundancy group. Also specify IP
addresses, a monitoring weight, a redundant Ethernet interface number, and a secondary IP monitoring
ping source for each IP address, for the redundancy group to monitor.

Options

IPv4 address The address to be continually monitored for reachability. You also set up a secondary IP
address to allow testing from the secondary node.

NOTE: All monitored object failures, including IP monitoring, are deducted from
the redundancy group threshold priority. Other monitored objects include
interface monitor, SPU monitor, cold-sync monitor, and NPC monitor (on
supported platforms).

interface interface secondary-ip- Define source address for monitoring packets on


address ip-address; secondary link.

global- Define global threshold for IP monitoring. See "global-threshold" on page 626.
threshold
• Default: 0

• Range: 0-255

global-weight Define global weight for IP monitoring. See "global-weight" on page 628.

• Default: 255

• Range: 0-255

retry-count Number of retries needed to declare reachablity failure. See "retry-count (Chassis
Cluster)" on page 704.

• Default: 5

• Range: 5-15
650

retry-interval Define the time interval in seconds between retries. See "retry-interval (Chassis Cluster)"
on page 706.

• Default: 1

• Range: 1-30

The remaining statements are explained separately. See CLI Explorer.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement updated in Junos OS Release 10.1.

RELATED DOCUMENTATION

Example: Configuring Chassis Cluster Redundancy Group IP Address Monitoring | 261

key-server-priority (MACsec)

IN THIS SECTION

Syntax | 651

Hierarchy Level | 651

Description | 651

Default | 651

Options | 652
651

Required Privilege Level | 652

Release Information | 652

Syntax

key-server-priority priority-number;

Hierarchy Level

[edit security macsec connectivity-association mka]

Description

Specifies the key server priority used by the MACsec Key Agreement (MKA) protocol to select the key
server when MACsec is enabled using static connectivity association key (CAK) security mode.

The switch with the lower priority-number is selected as the key server.

If the priority-number is identical on both sides of a point-to-point link, the MKA protocol selects the
device with the lower MAC address as the key server.

Default

The default key server priority number is 16.


652

Options

priority- Specifies the MKA server election priority number.


number
The priority-number can be any number between 0 and 255. The lower the number, the
higher the priority.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

lacp (Interfaces)

IN THIS SECTION

Syntax | 653

Hierarchy Level | 653

Description | 653
653

Options | 653

Required Privilege Level | 654

Release Information | 654

Syntax

lacp {
(active | passive);
periodic (fast | slow);
}

Hierarchy Level

[edit interfaces interface-name redundant-ether-options]

Description

For redundant Ethernet interfaces in a chassis cluster only, configure Link Aggregation Control Protocol
(LACP).

Options

• active—Initiate transmission of LACP packets.

• passive—Respond to LACP packets.

• Default—If you do not specify lacp as either active or passive, LACP remains off (the default).

• periodic—Interval for periodic transmission of LACP packets. The options are:


654

• fast—Transmit link aggregation control PDUs every second.

• slow—Transmit link aggregation control PDUs every 30 seconds.

• Default—If you do not specify periodic as either fast or fast, it is set to fast. If lacp is set to fast,
LACP is asking the link partner to send an LACP heartbeat every 1-second. If lacp is set to slow,
LACP is asking the link partner to send an LACP heartbeat every 30-seconds.

The remaining statements are explained separately. See CLI Explorer.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.2.

RELATED DOCUMENTATION

Understanding LACP on Standalone Devices


periodic (Interfaces)

link-protection (Chassis Cluster)

IN THIS SECTION

Syntax | 655

Hierarchy Level | 655

Description | 655
655

Options | 656

Required Privilege Level | 656

Release Information | 656

Syntax

link-protection {
non-revertive;
}

Hierarchy Level

[edit chassis aggregated-devices ethernet lacp]

Description

Enable Link Aggregation Control Protocol (LACP) link protection at the global (chassis) level.

By default LACP link protection reverts to a higher-priority (lower-numbered) link when the higher-
priority link becomes operational or when a higher-priority link is added to the aggregated Ethernet
bundle.

You can suppress link calculation by adding the non-revertive statement to the link protection
configuration. In nonrevertive mode, when a link is active in sending and receiving LACP packets, adding
a higher-priority link to the bundle does not change the status of the currently active link. It remains
active.
656

Options

non-revertive Disable the ability to switch to a better priority link (if one is available) after a link is
established as active and a collection or distribution is enabled.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.2.

RELATED DOCUMENTATION

cluster (Chassis) | 606


Example: Configuring Aggregated Ethernet Device with LAG and LACP on a Security Device (CLI
Procedure)

macsec

IN THIS SECTION

Syntax | 657

Hierarchy Level | 658

Description | 658

Options | 658

Required Privilege Level | 658


657

Release Information | 659

Syntax

macsec {
cluster-control-port <idx> {
connectivity-association connectivity-association-name;
}
cluster-data-port interface-name {
connectivity-association connectivity-association-name;
}
connectivity-associationconnectivity-association-name {
exclude-protocol protocol-name;
include-sci;
mka {
key-server-priority priority-number;
must-secure;
transmit-interval milliseconds;
}
no-encryption;
offset (0|30|50);
pre-shared-key {
cak hexadecimal-number;
ckn hexadecimal-number;
}
replay-protect {
replay-window-size number-of-packets;
}
security-mode security-mode;
}
traceoptions (Chassis Cluster){
file {
filename;
files number;
match regular-expression;
(world-readable | no-world-readable);
size maximum-file-size;
}
658

flag flag;
}
}

Hierarchy Level

[edit security]

Description

Configure Media Access Control Security (MACsec). Media Access Control Security(MACsec) is
supported on control and fabric ports of SRX340, SRX345, and SRX4600 devices in chassis cluster
mode to secure point-to-point Ethernet links between the peer devices in a cluster. Each point-to-point
Ethernet link must be configured independently to secure using MACsec. You can enable MACsec
encryption on device-to-device links using static connectivity association key (CAK) security mode.

Options

cluster-control-port <idx> Specify chassis cluster control interface on which MACsec is enabled.

• Values: 0.

cluster-data-port interface-name Specify chassis cluster fabric interface on which MACsec is enabled.

connectivity-association Create or configure a MACsec connectivity association.

traceoptions Define MACsec configuration tracing operations.

The remaining statements are explained separately. See CLI Explorer.

Required Privilege Level

admin—To view this statement in the configuration.


659

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Configuring Media Access Control Security (MACsec) | 489


Understanding Media Access Control Security (MACsec) | 486

mka

IN THIS SECTION

Syntax | 659

Hierarchy Level | 660

Description | 660

Options | 660

Required Privilege Level | 660

Release Information | 660

Syntax

mka {
must-secure;
key-server-priority priority-number;
transmit-interval interval;
}
660

Hierarchy Level

[edit security macsec connectivity-association]

Description

Specify parameters for the MACsec Key Agreement (MKA) protocol. You initially establish a MACsec-
secured link using a pre-shared key when you are using static CAK security mode to enable MACsec.
Once matching pre-shared keys are successfully exchanged, the MACsec Key Agreement (MKA)
protocol is enabled. The MKA protocol is responsible for maintaining MACsec on the link, and decides
which switch on the point-to-point link becomes the key server. The key server then creates an SAK that
is shared with the switch at the other end of the point-to-point link only, and that SAK is used to secure
all data traffic traversing the link.

Options

The remaining statements are explained separately.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


661

Configuring Media Access Control Security (MACsec) | 489


macsec | 656

network-management

IN THIS SECTION

Syntax | 661

Hierarchy Level | 661

Description | 662

Options | 662

Required Privilege Level | 662

Release Information | 662

Syntax

network-management {
cluster-master;
}

Hierarchy Level

[edit chassis cluster]


662

Description

Define parameters for network management. To manage an SRX Series Services Gateway cluster
through a non-fxp0 interface, use this command to define the node as a virtual chassis in NSM. This
command establishes a single DMI connection from the primary node to the NSM server. This
connection is used to manage both nodes in the cluster. Note that the non-fxp0 interface (regardless of
which node it is present on) is always controlled by the primary node in the cluster. The output of a
<get-system-information> RPC returns a <chassis-cluster> tag in all SRX Series Firewalls. When NSM
receives this tag, it models SRX Series clusters as devices with autonomous control planes.

Options

cluster-master—Enable in-band management on the primary cluster node through NSM.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 11.1.

RELATED DOCUMENTATION

cluster (Chassis) | 606


663

no-encryption (MACsec)

IN THIS SECTION

Syntax | 663

Hierarchy Level | 663

Description | 663

Default | 664

Required Privilege Level | 664

Release Information | 664

Syntax

no-encryption;

Hierarchy Level

[edit security macsec connectivity-association security-mode static-cak]

Description

Enable MACsec encryption within a secure channel.

You can enable MACsec without enabling encryption. If a connectivity association with a secure channel
that has not enabled MACsec encryption is associated with an interface, traffic is forwarded across the
Ethernet link in clear text. You are, therefore, able to view this unencrypted traffic when you are
monitoring the link. The MACsec header is still applied to the frame, however, and all MACsec data
integrity checks are run on both ends of the link to ensure the traffic has not been tampered with and
does not represent a security threat.
664

Traffic traversing a MAC-enabled point-to-point Ethernet link traverses the link at the same speed
regardless of whether encryption is enabled or disabled. You cannot increase the speed of traffic
traversing a MACsec-enabled Ethernet link by disabling encryption.

When MACsec is configuring using static connectivity association key (CAK) security mode, the
encryption setting is configured outside of the secure channel using the no-encryption configuration
statement.

Default

MACsec encryption is disabled when MACsec is configured, by default.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656
665

node (Chassis Cluster Redundancy Group)

IN THIS SECTION

Syntax | 665

Hierarchy Level | 665

Description | 665

Options | 666

Required Privilege Level | 666

Release Information | 666

Syntax

node (0 | 1 ) {
priority number;
}

Hierarchy Level

[edit chassis cluster redundancy-group group-number ]

Description

Identify each cluster node in a redundancy group and set its relative priority for primary role.

A redundancy group is collection of objects. A redundancy group contains objects on both nodes. A
redundancy group is primary on one node and backup on the other at any time. When a redundancy
group is said to be primary on a node, its objects on that node are active. The primacy of a redundancy
666

group is dependent on the priority configured for the node, the node ID (in case of tied priorities), and
the order in which the node comes up.

Options

node Cluster node number, You can set with the set chassis cluster node node-number statement.

• Values:

• 0—Node identifier 0

• 1—Node identifier 1

priority Priority value of the node. Each node is given a priority within a redundancy group. The
number eligible node with the highest priority is elected primary. Initiating a failover with the request
chassis cluster failover node or request chassis cluster failover redundancy-group command
overrides the priority settings.

• Range: 1-254

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

redundancy-group (Chassis Cluster) | 686


667

ntp

IN THIS SECTION

Syntax | 667

Hierarchy Level | 668

Description | 668

Options | 668

Required Privilege Level | 674

Release Information | 674

Syntax

ntp {
authentication-key key-number type (md5 | sha1 | sha256) value password;
boot-server (address | hostname);
broadcast <address> <key key-number> <routing-instance-name routing-instance-name> <ttl
value> <version value>;
broadcast-client;
interval-range value;
multicast-client <address>;
nts <local-certificate local-certificate><trusted-ca (trusted-ca-group trusted-ca-group |
trusted-ca-profile trusted-ca-profile)>;
peer address <key key-number> <prefer> <version value>;
restrict address {
mask network-mask;
noquery;
}
server name {
key key;
nts <remote-identity distinguished-name(container container | wildcard wildcard) hostname
hostname>;
prefer;
routing-instance routing-instance;
version version;
668

}
source-address source-address <routing-instance routing-instance-name>;
threshold value action (accept | reject);
trusted-key [ key-numbers ];
}

Hierarchy Level

[edit system]

Description

Configure NTP on the device. In both standalone and chassis cluster modes, the primary Routing Engine
runs the NTP process to get the time from the external NTP server. Although the secondary Routing
Engine runs the NTP process in an attempt to get the time from the external NTP server, this attempt
fails because of network issues. For this reason, the secondary Routing Engine uses NTP to get the time
from the primary Routing Engine.

When configuring the NTP service in the management VRF (mgmt_junos), you must configure at least one
IP address on a physical or logical interface within the default routing instance and ensure that this
interface is up in order for the NTP service to work with the mgmt_junos VRF.

Options

authentication-key Configure key (key ID, key type, and key value) to authenticate NTP packets
key_number with the devices (servers and clients). The authentication key has two fields:

• type—When authentication is specified, the key identifier (key ID) followed


by the message digest is appended to the NTP packet header. The
supported message digest formats are md5, sha1, sha256.
669

NOTE: EX4600 does not support SHA256 authentication for NTP


and supports MD5 only.

• value—If the key value is available in ASCII format and without special
characters, it can be entered directly. If the key value contains special
characters or is available in hex format, consider the following:

For specifying the keys in hex format, prepend a "\x" for each two
characters. For hex key example, af60112f...39af4ced,
set system ntp authentication-key <ID> value "\xaf\x60\x11\x2f\....\x39\xaf\x4c
\xed".

If the key contains one of the characters from (null) 0x00, (space) 0x20, "
0x22, & 0x26, ( 0x28 ) 0x29 prepend a "\\x" . For example, \\x22.

• Range: 1 to 65534

boot-server (address | Configure the server that NTP queries when the device boots to determine
hostname) the local date and time.

When you boot the device, it issues an ntpdate request, which polls a
network server to determine the local date and time. You must configure an
NTP boot server that the device uses to determine the time when the device
boots. Otherwise, NTP cannot synchronize to a time server if the server time
significantly differs from the local device’s time.

If you configure an NTP boot server, then when the device boots, it
immediately synchronizes with the boot server even if the NTP process is
explicitly disabled or if the time difference between the client and the boot
server exceeds the threshold value of 1000 seconds.

• Values: Configure one of the following:

• address—IP address of an NTP boot server.

• hostname—Hostname of an NTP boot server. If you configure a


hostname instead of an IP address, the ntpdate request resolves the
hostname to an IP address when the device boots up.

NOTE: This option is deprecated starting in Junos OS Release


20.4R1. NTP boot-server is not supported in Junos OS Evolved.
670

Configure the server using set system ntp server under the edit
system ntp server hierarchy.

broadcast <address> Configure the device to operate in broadcast mode with the remote system
<key key-number> at the specified address. In this mode, the device sends periodic broadcast
<routing-instance-name
routing-instance-name> messages to a client population at the specified broadcast or multicast
<ttl value> <version address. Normally, you include this statement only when the device is
value> operating as a transmitter.

address Configure the broadcast address on one of the local


networks or a multicast address assigned to NTP. You must
specify an address, not a hostname. If the multicast address
is used, it must be 224.0.1.1.

key key- (Optional) All packets sent to the address include


number authentication fields that are encrypted using the specified
key number (any unsigned 32-bit integer except 0). The key
corresponds to the key number you specified in the
authentication-key statement.

routing- (Optional) Configure the routing instance name in which the


instance- interface has an address in the broadcast subnet.
name
routing- • Default: The default routing instance is used to broadcast
instance-
name packets.

ttl value (Optional) Configure the time-to-live (TTL) value.

• Range: 1 through 255

• Default: 1

version value (Optional) Specify the version number to be used in outgoing


NTP packets.

• Range: 1 through 4

• Default: 4

broadcast-client Configure the local device to listen for broadcast messages on the local
network to discover other servers on the same subnet. To avoid accidental or
malicious disruption in this mode, both the local and remote systems must
use authentication and the same trusted key and key identifier.
671

interval-range value Configure the poll interval range.

• Range: 0 through 3

multicast-client Configure the local device to listen for multicast messages on the local
<address> network. To avoid accidental or malicious disruption in this mode, both the
local and remote systems must use authentication and the same trusted key
and key identifier.

• Syntax: <address>—(Optional) Specify one or more IP addresses. If you


specify addresses, the device joins those multicast groups.

• Default: 224.0.1.1

nts <local-certificate Configure the Network Time Security (NTS) features for NTP on your device.
local-
certificate><trusted-ca local-certificate Specify the certificate loaded in your device during
(trusted-ca-group local-certificate
trusted-ca-group | certificate enrollment or loaded manually by specifying
trusted-ca-profile certificate file.
trusted-ca-profile)
trusted-ca Specify a trusted CA group or a CA profile. This configuration is
optional. If you do not specify a trusted CA profile the NTP trust
all CA profiles configured for NTS.

trusted-ca-group trusted- Specify the trusted CA group defined under [set


ca-group security pki trusted-ca-group].

trusted-ca-profile trusted-ca-profile Specify the trusted CA profile.

peer address <key key- Configure the local device to operate in symmetric active mode with the
number> <prefer> remote system at the specified address. In this mode, the local device and
<version value>
the remote system can synchronize with each other. This configuration is
useful in a network in which either the local device or the remote system
might be a better source of time.

address Address of the remote system. You must specify an address, not
a hostname.

key key- (Optional) All packets sent to the address include authentication
number fields that are encrypted using the specified key number (any
unsigned 32-bit integer except 0). The key corresponds to the
key number you specified in the authentication-key statement.
672

prefer (Optional) Mark the remote system as the preferred host, which
means that if all other factors are equal, this remote system is
chosen for synchronization among a set of correctly operating
systems.

version (Optional) Specify the NTP version number to be used in


value outgoing NTP packets.

• Range: 1 through 4

• Default: 4

restrict address mask Restrict packets from hosts (including remote time servers) and subnets.
network-mask noquery
• Syntax:

• address—Specify the IP address for a host or network.

• mask network-mask—Specify the network mask for a host or network.

• noquery—Deny ntpq and ntpdc queries from hosts and subnets. These
queries can be used in amplification attacks.

server Configure the local device to operate in client mode with the remote system
at the specified address. In this mode, the device can be synchronized with
the remote system, but the remote system can never be synchronized with
the device.

If the NTP client time drifts so that the difference in time from the NTP
server exceeds 128 milliseconds, the client is automatically stepped back into
synchronization. If the offset between the NTP client and server exceeds the
1000-second threshold, the client still synchronizes with the server, but it
also generates a system log message noting that the threshold was exceeded.

address Address of the remote system. You must specify an address,


not a hostname.

key key- (Optional) All packets sent to the address include


number authentication fields that are encrypted using the specified key
number (any unsigned 32-bit integer except 0). The key
corresponds to the key number you specified in the
authentication-key statement.

prefer (Optional) Mark the remote system as the preferred host,


which means that if all other factors are equal, this remote
673

system is chosen for synchronization among a set of correctly


operating systems.

routing- (Optional) Routing instance through which the server is


instance reachable.
routing-
instance
nts Enables NTS, which uses Transport Layer Security (TLS)
protocol and Authenticated Encryption with Associated Data
(AEAD) to obtain network time in an authenticated manner to
the users. Specified server must also support the NTS feature
when you enable NTS on a client device.

version (Optional) Specify the NTP version number to be used in


value outgoing NTP packets.

• Range: 1 through 4

• Default: 4

source-addresssource- A valid IP address configured on one of the device’s interfaces to be used as


address <routing- the source address for messages sent to the NTP server, and optionally, the
instance [ routing-
instance-name ]> routing instance in which the source address is configured.

• Default: The primary address of the interface

threshold seconds Configure the maximum threshold in seconds allowed for NTP adjustment
action (accept | reject) and specify the mode for NTP abnormal adjustment.

• Range: 1 through 600 seconds

• Values: Configure one of the following:

• accept—Enable log mode for abnormal NTP adjustment.

• reject—Enable reject mode for abnormal NTP adjustment.

trusted-key [ key- Configure one or more keys you are allowed to use to authenticate other
numbers ] time servers, when you configure the local device to synchronize its time
with other systems on the network. Each key can be any 32-bit unsigned
integer except 0. The key corresponds to the key number you specify in the
authentication-key statement.

By default, network time synchronization is unauthenticated. The device


synchronizes to whatever system appears to have the most accurate time.
674

We strongly encourage you to configure authentication of network time


services.

Required Privilege Level

system—To view this statement in the configuration.

system-control—To add this statement to the configuration.

Release Information

Statement introduced before Junos OS Release 7.4.

routing-instance option for the server statement introduced in Junos OS Release 18.1.

restrict statement introduced in Junos OS Release 20.1.

RELATED DOCUMENTATION

Synchronizing and Coordinating Time Distribution Using NTP


Understanding NTP Time Servers
Configuring NTP Authentication Keys
NTP Time Synchronization on SRX Series Devices
Configuring the NTP Time Server and Time Services
Configuring the Switch to Listen for Broadcast Messages Using NTP
Configuring the Switch to Listen for Multicast Messages Using NTP
675

ntp threshold

IN THIS SECTION

Syntax | 675

Hierarchy Level | 675

Description | 675

Options | 676

Required Privilege Level | 676

Release Information | 676

Syntax

threshold value<action (accept | reject)>;

Hierarchy Level

[edit system ntp]

Description

Assign a threshold value for Network Time Protocol (NTP) adjustment that is outside of the acceptable
NTP update and specify whether to accept or reject NTP synchronization when the proposed time from
the NTP server exceeds the configured threshold value. If accept is the specified action, the system
synchronizes the device time with the NTP server, but logs the time difference between the configured
threshold and the time proposed by the NTP server; if reject is the specified action, synchronization
with the time proposed by the NTP server is rejected, but the system provides the option of manually
synchronizing the device time with the time proposed by the NTP server and logs the time difference
676

between the configured threshold and the time proposed by the NTP server. By logging the time
difference and rejecting synchronization when the configured threshold is exceeded, this feature helps
improve security on the NTP service.

If this command is not configured or by default, the NTP will allow time adjustments for up to 1000
seconds except for first time adjustment. After NTP synchronization starts, it will allow first time
adjustment to happen without any time limit. After first time adjustment happens, 1000 seconds time
limit will be enforced for future time adjustments.

Options

value Specify the maximum value in seconds allowed for NTP adjustment.

• Range: 1 through 600.

• Default: The default value is 400.

action Specify the actions for NTP abnormal adjustment.

• accept—Enable log mode for abnormal NTP adjustment. When the proposed time from the
NTP server is outside of the configured threshold value, the device time synchronizes with
the NTP server, but the system logs the time difference between the configured threshold
and the time proposed by the NTP server.

• reject—Enable log and reject mode for abnormal NTP adjustment. When the proposed time
from the NTP server is outside of the configured threshold value, the system rejects
synchronization, but provides the option for manually synchronizing the time and logs the
time difference between the configured threshold and the time proposed by the NTP server.

Required Privilege Level

security—To view this statement in the configuration.

security-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D70.


677

RELATED DOCUMENTATION

ntp
set date ntp | 957
show system ntp threshold | 959
NTP Time Synchronization on SRX Series Devices | 360

offset

IN THIS SECTION

Syntax | 677

Hierarchy Level | 677

Description | 678

Default | 678

Options | 678

Required Privilege Level | 679

Release Information | 679

Syntax

offset (0 |30 | 50);

Hierarchy Level

[edit security macsec connectivity-association]


[edit security macsec connectivity-association security-mode static-cakl]
678

Description

Specifies the number of octets in an Ethernet frame that are sent in unencrypted plain-text when
encryption is enabled for MACsec.

Setting the offset to 30 allows a feature to see the IPv4 header and the TCP/UDP header while
encrypting the remaining traffic. Setting the offset to 50 allows a feature to see the IPv6 header and the
TCP/UDP header while encrypting the remaining traffic.

You would typically forward traffic with the first 30 or 50 octets unencrypted if a feature needed to see
the data in the octets to perform a function, but you otherwise prefer to encrypt the remaining data in
the frames traversing the link. Load balancing features, in particular, typically need to see the IP and
TCP/UDP headers in the first 30 or 50 octets to properly load balance traffic.

You configure the offset in the [edit security macsec connectivity-association] hierarchy when you are
enabling MACsec using static connectivity association key (CAK) or dynamic security mode.

Default

Options

0 Specifies that no octets are unencrypted. When you set the offset to 0, all traffic on the interface
where the connectivity association or secure channel is applied is encrypted.

30 Specifies that the first 30 octets of each Ethernet frame are unencrypted.

NOTE: In IPv4 traffic, setting the offset to 30 allows a feature to see the IPv4 header and
the TCP/UDP header while encrypting the rest of the traffic. An offset of 30, therefore, is
typically used when a feature needs this information to perform a task on IPv4 traffic.

50 Specified that the first 50 octets of each Ethernet frame are unencrypted.
679

NOTE: In IPv6 traffic, setting the offset to 50 allows a feature to see the IPv6 header and
the TCP/UDP header while encrypting the rest of the traffic. An offset of 50, therefore, is
typically used when a feature needs this information to perform a task on IPv6 traffic.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

preempt (Chassis Cluster)

IN THIS SECTION

Syntax | 680

Hierarchy Level | 680

Description | 680

Options | 681
680

Required Privilege Level | 681

Release Information | 681

Syntax

preempt {
delay seconds;
limit limit;
period seconds;
}

Hierarchy Level

[edit chassis cluster redundancy-group group-number]

Description

Allow preemption of the primary system based on the priority within a redundancy group.

Configuring preemption for RG0 is not allowed and is blocked when committed.

By configuring the preemptive delay timer and failover limit, you can limit the flapping of the
redundancy group state between the secondary and the primary in a preemptive failover.

By default, preemption is disabled.

Example: Consider the following scenario where you have configured a preemptive period as 300
seconds and preemptive limit as 50.

When the preemptive limit is configured as 50, the count starts at 0 and increments with a first
preemptive failover; this process continues until the count reaches the configured preemptive limit, that
is 50, before the preemptive period expires. When the preemptive limit (50) is exceeded, you must
manually reset the preempt count to allow preemptive failovers to occur again.
681

When you have configured the preemptive period as 300 seconds, and if the time difference between
the first preemptive failover and the current failover has already exceeded 300 seconds, and the
preemptive limit (50) is not yet reached, then the preemptive period will be reset. After resetting, the
last failover is considered as the first preemptive failover of the new preemptive period and the process
starts all over again.

Options

delay Time to wait before the node in secondary state transitions to primary state in a preemptive
failover.

• Range: 1 to 21,600 seconds

• Default: 1

limit Maximum number of preemptive failovers allowed in a configured preemptive period.

• Range: 1 to 50

period Time period during which the preemptive limit is applied.

• Range: 1 to 1400 seconds

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.0. Support for delay, limit, and period options are added in
Junos OS Release 17.4R1.

RELATED DOCUMENTATION

redundancy-group (Chassis Cluster) | 686


682

Understanding Chassis Cluster Redundancy Group Failover | 283

pre-shared-key

IN THIS SECTION

Syntax | 682

Hierarchy Level | 682

Description | 683

Default | 683

Options | 683

Required Privilege Level | 683

Release Information | 683

Syntax

pre-shared-key {
cak hexadecimal-number;
ckn hexadecimal-number;
}

Hierarchy Level

[edit security macsec connectivity-association]


683

Description

Specifies the pre-shared key used to enable MACsec using static connectivity association key (CAK)
security mode.

A pre-shared key includes a connectivity association key name (CKN) and a connectivity association key
(CAK). A pre-shared key is exchanged between two devices at each end of a point-to-point link to
enable MACsec using static CAK security mode. The MACsec Key Agreement (MKA) protocol is enabled
after the pre-shared keys are successfully verified and exchanged. The pre-shared key—the CKN and
CAK—must match on both ends of a link.

Default

No pre-shared keys exist, by default.

Options

The remaining statements are explained separately.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
684

macsec | 656

priority (Protocols VRRP)

IN THIS SECTION

Syntax | 684

Hierarchy Level | 684

Description | 685

Options | 685

Required Privilege Level | 685

Release Information | 685

Syntax

priority priority;

Hierarchy Level

[edit interfaces interface-name unit logical-unit-number family inet address address vrrp-
group group-id],
[edit interfaces interface-name unit logical-unit-number family inet6 address address vrrp-inet6-
group group-id],
[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number
family inet address address vrrp-group group-id],
[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number
family inet6 address address vrrp-inet6-group group-id]
685

Description

Configure a Virtual Router Redundancy Protocol (VRRP) device’s priority for becoming the primary
default device. The device with the highest priority within the group becomes the primary. VRRP is
designed to eliminate the single point of failure inherent in the static default routed environment. VRRP
specifies an election protocol that dynamically assigns responsibility for a virtual router to one of the
VRRP routers on a LAN. The VRRP router controlling the IP address(es) associated with a virtual router
is called the Primary, and forwards packets sent to these IP addresses. The election process provides
dynamic fail-over in the forwarding responsibility when the Primary become unavailable. Any of the
virtual router's IP addresses on a LAN can then be used as the default first hop router by end-hosts. The
advantage gained from using VRRP is a higher availability default path without requiring configuration of
dynamic routing or router discovery protocols on every end-host.

Options

priority Device’s priority for being elected to be the primary device in the VRRP group. A larger value
indicates a higher priority for being elected.

• Range: 0 through 255

• Default: 100. If two or more devices have the highest priority in the VRRP group, the device with the
VRRP interface that has the highest IP address becomes the primary, and the others serve as
backups.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced before Junos OS Release 7.4.


686

RELATED DOCUMENTATION

Configuring Basic VRRP Support


Understanding VRRP on SRX Series Firewalls | 329
Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant Ethernet Interfaces | 335

redundancy-group (Chassis Cluster)

IN THIS SECTION

Syntax | 686

Hierarchy Level | 687

Description | 687

Options | 688

Required Privilege Level | 688

Release Information | 689

Syntax

redundancy-group group-number {
gratuitous-arp-count number;
hold-down-interval number;
interface-monitor interface-name {
weight number;
}
ip-monitoring{
family {
inet {
ipv4-address {
interface {
logical-interface-name;
secondary-ip-address ip-address;
}
687

weight number;
}
}
}
global-threshold number;
global-weight number;
retry-count number;
retry-interval seconds;
}
node (0 | 1 ) {
priority number;
}
preempt (Chassis Cluster){
delay seconds;
limit limit;
period seconds;
}
}

Hierarchy Level

[edit chassis cluster]

Description

Define a redundancy group. Except for redundancy group 0, a redundancy group is a logical interface
consisting of two physical Ethernet interfaces, one on each chassis. One interface is active, and the
other is on standby. When the active interface fails, the standby interface becomes active. The logical
interface is called a redundant Ethernet interface (reth).

Redundancy group 0 consists of the two Routing Engines in the chassis cluster and controls which
Routing Engine is primary. You must define redundancy group 0 in the chassis cluster configuration.
688

Options

group-number Redundancy group identification number.

NOTE: The maximum number of redundancy groups is equal to the number


of redundant Ethernet interfaces that you configure.

• Range: 0 through 128

interface-monitor Specify a redundancy group interface to be monitored for failover and the relative
weight of the interface.

ip-monitor Specify IP address of interface to be monitored for end-to-end connectivity.

gratuitous-arp- Number of gratuitous ARPs to send on an active interface after failover


count
• Range: 1-16

hold-down- RG failover interval. RG0(300-1800) RG1+(0-1800) (seconds)


interval
• Range: 0-1800

node Identify each cluster node in a redundancy group and set its relative priority for
primary role.

preempt Allow preemption of the primary system based on the priority within a redundancy
group.

The remaining statements are explained separately. See CLI Explorer.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


689

Release Information

Statement introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

ip-monitoring | 647

redundant-ether-options

IN THIS SECTION

Syntax | 689

Hierarchy Level | 690

Description | 690

Options | 690

Required Privilege Level | 691

Release Information | 691

Syntax

redundant-ether-options {
(flow-control | no-flow-control);
lacp {
(active | passive);
periodic (fast | slow);
}
link-speed speed;
(loopback | no-loopback);
minimum-links number;
redundancy-group number;
source-address-filter mac-address;
690

(source-filtering | no-source-filtering);
}

Hierarchy Level

[edit interfaces interface-name]

Description

Configure Ethernet redundancy options for a chassis cluster.

In a chassis cluster setup, a redundant Ethernet interface is a pseudointerface that includes at minimum
one physical interface from each node of the cluster.

A reth is a special type of interface that has the characteristics of aggregated Ethernet interface.

Options

flow-control Enable flow control.

link-speed Link speed of individual interface that joins the reth interface.

• Values:

• 100m—Links are 100 Mbps

• 10g—Links are 10 Gbps

• 10m—Links are 10 Mbps

• 1g—Links are 1Gbps

loopback Enable loopback.

minimum-links Minimum number of active links.


691

• Default: 1

• Range: 1-8

no-flow-control Do not enable flow control.

no-loopback Do not enable loopback.

no-source-filtering Do not enable source address filtering.

redundancy-group Redundancy group of this interface.

• Range: 1-128

source-filtering Enable source address filtering.

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.2.

RELATED DOCUMENTATION

Example: Enabling Eight-Queue Class of Service on Redundant Ethernet Interfaces on SRX Series
Firewalls in a Chassis Cluster | 153
Example: Configuring Chassis Cluster Redundant Ethernet Interfaces | 103
692

redundant-parent (Interfaces)

IN THIS SECTION

Syntax | 692

Hierarchy Level | 692

Description | 692

Options | 693

Required Privilege Level | 693

Release Information | 693

Syntax

redundant-parent redundant-ethernet-interface-name;

Hierarchy Level

[edit interfaces interface-name gigether-options]


[edit interfaces interface-name fastether-options]

Description

Specify redundant Ethernet interfaces (reth) and assign local (child) interfaces to the reth interfaces. A
redundant Ethernet interface contains a pair of Fast Ethernet interfaces or a pair of Gigabit Ethernet
interfaces that are referred to as child interfaces of the redundant Ethernet interface.
693

Options

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.2.

RELATED DOCUMENTATION

Example: Configuring Chassis Cluster Redundant Ethernet Interfaces | 103

redundant-pseudo-interface-options

IN THIS SECTION

Syntax | 694

Hierarchy Level | 694

Description | 694

Options | 694

Required Privilege Level | 694

Release Information | 695


694

Syntax

redundant-pseudo-interface-options {
redundancy-group redundancy-group-number;
}

Hierarchy Level

[edit interfaces lo0]

Description

Configure the loopback pseudointerface in a redundancy group.

Redundancy groups are used to bundle interfaces into a group for failover purpose in a chassis cluster
setup. You can configure a loopback interface as an alternative physical interface to reach the peer
gateway. Loopback interfaces can be configured on any redundancy group.

For example: An Internet Key Exchange (IKE) gateway operating in chassis cluster, needs an external
interface to communicate with a peer device. When an external interface (a reth interface or a
standalone interface) is used for communication; the interface might go down when the physical
interfaces are down. Instead, use loopback interfaces as an alternative to physical interfaces.

Options

redundancy-group-number Configure the redundancy group number.

• Range: 0 through 255

Required Privilege Level

interface—To view this statement in the configuration.


695

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 12.1X44-D10.

RELATED DOCUMENTATION

Understanding the Loopback Interface for a High Availability VPN

replay-protect

IN THIS SECTION

Syntax | 695

Hierarchy Level | 696

Description | 696

Options | 696

Required Privilege Level | 696

Release Information | 697

Syntax

replay-protect {
replay-window-size number-of-packets;
}
696

Hierarchy Level

[edit security macsec connectivity-association]

Description

Enable replay protection for MACsec.

A replay window size specified using the replay-window-sizenumber-of-packets statement must be


specified to enable replay protection. When replay protection is enabled, the receiving interface checks
the ID number of all packets that have traversed the MACsec-secured link. If a packet arrives out of
sequence and the difference between the packet numbers exceeds the replay protection window size,
the packet is dropped by the receiving interface. For instance, if the replay protection window size is set
to five and a packet assigned the ID of 1006 arrives on the receiving link immediately after the packet
assigned the ID of 1000, the packet that is assigned the ID of 1006 is dropped because it falls outside
the parameters of the replay protection window. Replay protection is especially useful for fighting man-
in-the-middle attacks.

A packet that is replayed by a man-in-the-middle attacker on the Ethernet link will arrive on the
receiving link out of sequence, so replay protection helps ensure the replayed packet is dropped instead
of forwarded through the network. Replay protection should not be enabled in cases where packets are
expected to arrive out of order. You can require that all packets arrive in order by setting the replay
window size to 0.

Replay protection should not be enabled in cases where packets are expected to arrive out of order.

Options

The remaining statements are explained separately.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.


697

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

replay-window-size

IN THIS SECTION

Syntax | 697

Hierarchy Level | 698

Description | 698

Default | 698

Options | 698

Required Privilege Level | 699

Release Information | 699

Syntax

replay-window-size number-of-packets;
698

Hierarchy Level

[edit security macsec connectivity-association replay-protect]

Description

Specifies the size of the replay protection window.

This statement has to be configured to enable replay protection.

When MACsec is enabled on an Ethernet link, an ID number is assigned to each packet entering the link.
The ID number of the packet is checked by the receiving interface after the packet has traversed the
MACsec-enabled link.

When replay protection is enabled, the sequence of the ID number of received packets are checked. If
the packet arrives out of sequence and the difference between the packet numbers exceeds the replay
protection window size, the packet is dropped by the receiving interface. For instance, if the replay
protection window size is set to five and a packet assigned the ID of 1006 arrives on the receiving link
immediately after the packet assigned the ID of 1000, the packet that is assigned the ID of 1006 is
dropped because it falls outside the parameters of the replay protection window.

Replay protection is especially useful for fighting man-in-the-middle attacks. A packet that is replayed by
a man-in-the-middle attacker on the Ethernet link will arrive on the receiving link out of sequence, so
replay protection helps ensure the replayed packet is dropped instead of forwarded through the
network.

Replay protection should not be enabled in cases where packets are expected to arrive out of order.

Default

Replay protection is disabled.

Options

number-of- Specifies the size of the replay protection window, in packets.


packets
699

When this variable is set to 0, all packets that arrive out-of-order are dropped. The
maximum out-of-order number-of-packets that can be configured is 65535.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

resource-watch

IN THIS SECTION

Syntax | 700

Hierarchy Level | 700

Description | 700

Options | 701

Required Privilege Level | 702

Release Information | 702


700

Syntax

resource-watch {
cpu-statistics;
junos-statistics;
orange-zone-enable;
orange-zone-threshold;
red-zone-cpu-threshold;
red-zone-enable;
red-zone-jkl-threshold;
red-zone-snmp-enable;
resource-watch-enable;
}

Hierarchy Level

[edit chassis]

Description

In SRX chassis cluster mode, split brain caused by redundant failover is triggered due to Routing Engine
busy related to CPU overhead causing SRX HA cluster resiliency. To analyze CPU load, Reswatchd is a
process running on Linux, Routing Engine3, and Routing Engine2 to collect and monitor the resource
usage data. You can generate CPU load statistics report to analyze the system load (resource assignment
and Junos kernel usage). You can enable statistics function through CLI to log CPU usage every second
and generate a statistics report. This feature is supported on chassis standalone mode to monitor
Routing Engine CPU usage and Junos kernel usage and is disabled by default.

Resource availability is classified to three zones:

For RE2, the threshold values are:

• Green: CPU idle > 20%

• Orange: CPU idle <= 15%

• Red: CPU idle <= 5% or Junos Kernel load >= 50%


701

For RE3, the threshold values are:

• Green: CPU idle > 10%

• Orange: CPU idle <= 10%

• Red: CPU idle <= 3% or Junos Kernel load >= 50%

Options

cpu-statistics Display CPU load statistics report. When enable CPU statistics, reswatchd logs
CPU idle values /var/log/reswatch_CPU_statistics_[1-5] in .csv format.

• Range: 0-604800 seconds.

• Values:

• 0—Disable

junos-statistics Display Junos kernel statistics report. When enable Junos Kernel statistics,
reswatchd logs Junos Kernel usage values at /var/log/
reswatch_JK_statistics_[1-5] in .csv format.

• Range: 0-604800 seconds.

• Values:

• 0—Disable

orange-zone-enable Enable orange zone.

orange-zone- Specify orange zone value (CPU idle %)


threshold
• Default: 20

• Range: 1-99

red-zone-cpu- Specify red zone value (CPU idle %).


threshold
• Default: 10

• Range: 1-99

red-zone-enable Enable red zone.


702

red-zone-jkl- Specify red zone value (Junos load %)


threshold
• Default: 50

• Range: 1-99

red-zone-snmp- Enable red zone snmp.


enable
resource-watch- Enable resource watch.
enable

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS release 20.4R1.

RELATED DOCUMENTATION

show chassis reswatch | 896

reth-count (Chassis Cluster)

IN THIS SECTION

Syntax | 703

Hierarchy Level | 703

Description | 703

Options | 703
703

Required Privilege Level | 704

Release Information | 704

Syntax

reth-count number;

Hierarchy Level

[edit chassis cluster]

Description

Specify the number of redundant Ethernet (reth) interfaces allowed in the chassis cluster. You need to
specify the total number of interfaces in the chassis cluster before redundant Ethernet interfaces are
created. For example, the set chassis cluster reth-count 2 allow you to create two reth interfaces
(example: reth0 and reth1)

Note that the number of reth interfaces configured determines the number of redundancy groups that
can be configured and each SRX Series Firewall has a maximum number of reths that it can support.

Options

number —Number of redundant Ethernet interfaces allowed.

• Range: 1 through 128

• Default: 0
704

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

cluster (Chassis) | 606

retry-count (Chassis Cluster)

IN THIS SECTION

Syntax | 704

Hierarchy Level | 705

Description | 705

Options | 705

Required Privilege Level | 705

Release Information | 706

Syntax

retry-count number;
705

Hierarchy Level

[edit chassis cluster redundancy-groupgroup-number ip-monitoring ]

Description

Specify the number of consecutive ping attempts that must fail before an IP address monitored by the
redundancy group is declared unreachable in IP address monitoring.

In the IP address monitoring, you can configure redundancy groups to monitor upstream resources by
pinging specific IP addresses that are reachable through redundant Ethernet interfaces on either node in
a cluster. In this configuration, the retry interval determines the ping interval for each IP address
monitored by the redundancy group and the retry count sets the number of allowed consecutive ping
failures for each IP address monitored by the redundancy group.

(See "retry-interval (Chassis Cluster)" on page 706 for a related redundancy group IP address
monitoring variable.)

Options

number—Number of consecutive ping attempt failures before a monitored IP address is declared


unreachable.

• Default: 5

• Range: 5-15

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


706

Release Information

Statement introduced in Junos OS Release 10.1.

RELATED DOCUMENTATION

cluster (Chassis) | 606

retry-interval (Chassis Cluster)

IN THIS SECTION

Syntax | 706

Hierarchy Level | 706

Description | 707

Options | 707

Required Privilege Level | 707

Release Information | 707

Syntax

retry-interval interval;

Hierarchy Level

[edit chassis cluster redundancy-group group-number ip-monitoring ]


707

Description

Specify the ping packet send frequency (in seconds) for each IP address monitored by the redundancy
group.

In the IP address monitoring, you can configure redundancy groups to monitor upstream resources by
pinging specific IP addresses that are reachable through redundant Ethernet interfaces on either node in
a cluster. In this configuration, the retry interval determines the ping interval for each IP address
monitored by the redundancy group and the retry count sets the number of allowed consecutive ping
failures for each IP address monitored by the redundancy group.

(See "retry-count (Chassis Cluster)" on page 704 for a related IP address monitoring configuration
variable.)

Options

interval—Pause time (in seconds) between each ping sent to each IP address monitored by the
redundancy group.

• Default: 1

• Range: 1-30

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 10.1.

RELATED DOCUMENTATION

ip-monitoring | 647
708

route-active-on

IN THIS SECTION

Syntax | 708

Hierarchy Level | 708

Description | 708

Options | 709

Required Privilege Level | 709

Release Information | 709

Syntax

route-active-on (node0 | node1);

Hierarchy Level

[edit policy-options condition condition-name]

Description

In chassis cluster configurations, the incoming traffic from the core network is sent to the interface that
exists on the current active node . For a route advertised by BGP, a policy is applied on BGP
configuration before exporting routes. An additional term in the policy match condition determines the
current active device (node) before making the routing decision. In this way, the traffic is processed by
the active node.
709

Options

node0 Route active on node 0

node1 Route active on node 1

Required Privilege Level

routing—To view this statement in the configuration.

routing-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

cluster (Chassis) | 606


Example: Configuring Conditional Route Advertising in a Chassis Cluster | 166

scb-control-ports

IN THIS SECTION

Syntax | 710

Hierarchy Level | 710

Description | 710

Options | 710

Required Privilege Level | 710


710

Release Information | 711

Syntax

scb-control-ports Control board number;

Hierarchy Level

[edit chassis cluster]

Description

You can enable the primary control link connected through control board member. SCB control ports are
supported on single and dual control links.

Options

cb Specify the control board number.

• Range: 0 through 2

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


711

Release Information

Statement introduced in Junos OS Release 21.4R1.

RELATED DOCUMENTATION

Chassis Cluster Dual Control Links | 172

security-mode

IN THIS SECTION

Syntax | 711

Hierarchy Level | 711

Description | 712

Options | 712

Required Privilege Level | 712

Release Information | 713

Syntax

security-mode security-mode;

Hierarchy Level

[edit security macsec connectivity-association]


712

Description

Configure the MACsec security mode for the connectivity association.

We recommend enabling MACsec on switch-to-switch Ethernet links using static connectivity


association key (CAK) security mode. Static CAK security mode ensures security by frequently
refreshing to a new random secure association key (SAK) and by only sharing the SAK between the two
devices on the MACsec-secured point-to-point link. Additionally, some optional MACsec features—
replay protection, SCI tagging, and the ability to exclude traffic from MACsec—are only available when
you enable MACsec using static CAK security mode.

Options

security- Specifies the MACsec security mode. Options include:


mode
• dynamic—Dynamic mode.

Dynamic security mode is used to enable MACsec on switch-to-host Ethernet links. In


dynamic mode, a master key is retrieved from a RADIUS server by a switch and a host as
part of the AAA handshake in separate transactions. The MKA protocol is enabled when
the master key is exchanged between the switch and the host.

• static-cak —Static connectivity association key (CAK) mode.

Static CAK security mode is used to enable MACsec on switch-to-switch Ethernet links.
In static-cak mode, the switch at one end of the point-to-point link acts as the key server
and regularly transmits a randomized key using a process that does not transmit any
traffic outside of the MACsec-secured point-to-point link.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.


713

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

traceoptions (Chassis Cluster)

IN THIS SECTION

Syntax | 713

Hierarchy Level | 714

Description | 714

Options | 714

Required Privilege Level | 715

Release Information | 715

Syntax

traceoptions {
file {
filename;
files number;
match regular-expression;
(world-readable | no-world-readable);
size maximum-file-size;
}
714

flag flag;
level {
(alert | all | critical | debug | emergency | error | info | notice | warning);
}
no-remote-trace;
}

Hierarchy Level

[edit chassis cluster]

Description

Define chassis cluster redundancy process tracing operations.

A minimum traceoptions configuration must include both a target file and a flag. The target file
determines where the trace output is recorded. The flag defines what type of data is collected.

Options

• file filename —Name of the file to receive the output of the tracing operation. Enclose the name
within quotation marks. All files are placed in the directory /var/log.

• files number —(Optional) Maximum number of trace files. When a trace file named trace-file reaches
its maximum size, it is renamed to trace-file .0, then trace-file.1 , and so on, until the maximum
number of trace files is reached. The oldest archived file is overwritten.

• If you specify a maximum number of files, you also must specify a maximum file size with the size
option and a filename.

• Range: 2 through 1000 files

• Default: 10 files

• match regular-expression —(Optional) Refine the output to include lines that contain the regular
expression.
715

• size maximum-file-size —(Optional) Maximum size of each trace file, in kilobytes (KB), megabytes (MB),
or gigabytes (GB). When a trace file named trace-file reaches this size, it is renamed trace-file .0.
When the trace-file again reaches its maximum size, trace-file .0 is renamed trace-file .1 and trace-
file is renamed trace-file .0. This renaming scheme continues until the maximum number of trace
files is reached. Then the oldest trace file is overwritten.

• If you specify a maximum file size, you also must specify a maximum number of trace files with the
files option and filename.

• Syntax: x k to specify KB, x m to specify MB, or x g to specify GB

• Range: 0 KB through 1 GB

• Default: 128 KB

• world-readable | no-world-readable—(Optional) By default, log files can be accessed only by the user who
configures the tracing operation. The world-readable option enables any user to read the file. To
explicitly set the default behavior, use the no-world-readable option.

• flag—Trace operation or operations to perform on chassis cluster redundancy processes. To specify


more than one trace operation, include multiple flag statements.

• all—Trace all the events

• configuration—Trace configuration events

• routing-socket—Trace logging of rtsock activity

• snmp—Trace SNMP events

Required Privilege Level

trace—To view this statement in the configuration.

trace-control—To add this statement to the configuration.

Release Information

Statement modified in Junos OS Release 9.5.


716

RELATED DOCUMENTATION

cluster (Chassis) | 606

transmit-interval (MACsec)

IN THIS SECTION

Syntax | 716

Hierarchy Level | 716

Description | 716

Default | 717

Options | 717

Required Privilege Level | 717

Release Information | 717

Syntax

transmit-interval interval;

Hierarchy Level

[edit security macsec connectivity-association mka]

Description

Specifies the transmit interval for MACsec Key Agreement (MKA) protocol data units (PDUs).
717

The MKA transmit interval setting sets the frequency for how often the MKA PDU is sent to the directly
connected device to maintain MACsec on a point-to-point Ethernet link. A lower interval increases
bandwidth overhead on the link; a higher interval optimizes the MKA protocol data unit exchange
process.

The transmit interval settings must be identical on both ends of the link when MACsec using static
connectivity association key (CAK) security mode is enabled.

We recommend increasing the interval to 6000 ms in high-traffic load environments.

Default

The default transmit interval is 10000 milliseconds (10 seconds).

NOTE: Configuring aggressive transmit interval will lead to broken chassis cluster.

Options

interval Specifies the transmit interval, in milliseconds.

Required Privilege Level

admin—To view this statement in the configuration.

admin-control—To add this statement to the configuration.

Release Information

Statement introduced in Junos OS Release 15.1X49-D60.


718

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656

use-active-child-mac-on-reth

IN THIS SECTION

Syntax | 718

Hierarchy Level | 718

Description | 718

Required Privilege Level | 719

Release Information | 719

Syntax

use-active-child-mac-on-reth;

Hierarchy Level

[edit chassis cluster]

Description

Copy child's physical MAC address on RETH parent's current MAC address on KVM based systems.
719

NOTE: The commands use-active-child-mac-on-reth and use-actual-mac-on-physical-interfaces need to


be configured together for the feature to work.

Required Privilege Level

interface

Release Information

Statement introduced in Junos OS Release 19.4R1.

use-actual-mac-on-physical-interfaces

IN THIS SECTION

Syntax | 719

Hierarchy Level | 720

Description | 720

Required Privilege Level | 720

Release Information | 720

Syntax

use-actual-mac-on-physical-interfaces;
720

Hierarchy Level

[edit chassis cluster]

Description

Configure this command so that SR-IOV uses hypervisor’s provided MAC address for physical interfaces
on KVM based systems.

NOTE: The commands use-active-child-mac-on-reth and use-actual-mac-on-physical-interfaces need to


be configured together for the feature to work.

Required Privilege Level

interface

Release Information

Statement introduced in Junos OS Release 19.4R1.

virtual-address

IN THIS SECTION

Syntax | 721

Hierarchy Level | 721

Description | 721
721

Options | 721

Required Privilege Level | 722

Release Information | 722

Syntax

virtual-address [ addresses ];

Hierarchy Level

[edit interfaces interface-name unit logical-unit-number family inet address address vrrp-
group group-id],
[edit logical-systems logical-system-name interfaces interface-name unit logical-unit-number
family inet address address vrrp-group group-id]

Description

Configure the addresses of the devices in a Virtual Router Redundancy Protocol (VRRP) IPv4 or IPv6
group. You can configure up to eight addresses.

Options

addresses Addresses of one or more devices. Do not include a prefix length. If the address is the same
as the interface’s physical address, the interface becomes the primary device for the group.
722

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.

Release Information

Statement introduced before Junos OS Release 7.4.

RELATED DOCUMENTATION

Configuring Basic VRRP Support


Understanding VRRP on SRX Series Firewalls | 329
Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant Ethernet Interfaces | 335

vrrp-group

IN THIS SECTION

Syntax | 723

Hierarchy Level | 724

Description | 724

Options | 724

Required Privilege Level | 725

Release Information | 726


723

Syntax

vrrp-group group-id {
(accept-data | no-accept-data);
advertise-interval seconds;
advertisements-threshold number;
authentication-key key;
authentication-type (md5 | simple);
fast-interval milliseconds;
no-accept-data;
no-preempt;
preempt {
hold-time seconds;
}
preferred;
priority number;
track {
interface name {
bandwidth-threshold bits-per-second priority-cost priority {
priority-cost priority;
}
}
priority-hold-time seconds;
route route_address {
routing-instance;
}
}
virtual-addressvirtual-link-local-address;
vrrp-inherit-from {
active-group active-group;
active-interface active-interface;
}
}
724

Hierarchy Level

[edit interfaces name unit name family inet address],


[edit interfaces name unit name family inet inet6 address]

Description

The Routing Engine performs one-by-one state change for subsequent VRRP groups. Every time there is
a state change, and the new state for a particular VRRP group is primary, the Routing Engine generates
appropriate VRRP announcement messages. When the first VRRP group detected by the Routing Engine
changes state, and the new state is primary, the Routing Engine generates appropriate VRRP
announcement messages. The Packet Forwarding Engine is informed about the state change, so that
hardware filters for that group are reprogrammed without delay. The new primary then sends gratuitous
ARP message to the VRRP groups.

Options

group-id VRRP group identifier. If you enable MAC source address filtering on the
interface, you must include the virtual MAC address in the list of source
MAC addresses that you specify in the source-address-filter statement.
MAC addresses ranging from 00:00:5e:00:53:00 through 00:00:5e:00:53:ff
are reserved for VRRP, as defined in RFC 2338. The VRRP group number
must be the decimal equivalent of the last hexadecimal byte of the virtual
MAC address.

• Range: 0 through 255

accept-data Accept packets destined for virtual IP address

advertise-interval Advertisement interval (seconds)

• Range: 1 through 255

inet6-advertise-interval Inet6 advertisement interval (milliseconds)

• Range: 100-40000

advertisements-threshold Number of vrrp advertisements missed before declaring primary down


725

• Range: 1 through15

authentication-key Authentication key

authentication-type Authentication type

• Values:

• md5—HMAC-MD5-96

• simple—Simple password

fast-interval Fast advertisement interval (milliseconds)

• Range: 10 through 40950

no-accept-data Don't accept packets destined for virtual IP address

no-preempt Don't allow preemption

preempt Allow preemption

preferred Preferred group on subnet

priority Device election priority

• Range: 0 through 255

track Interfaces to track for VRRP group

virtual-address One or more virtual IPv4 addresses

virtual-inet6-address One or more virtual inet6 addresses

vrrp-inherit-from VRRP group to follow for the vrrp-group or vrrp-inet6-group

The remaining statements are explained separately. See CLI Explorer.

Required Privilege Level

interface
726

Release Information

Statement introduced before Junos OS Release 18.1R1.

RELATED DOCUMENTATION

Understanding VRRP on SRX Series Firewalls | 329


Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant Ethernet Interfaces

weight

IN THIS SECTION

Syntax | 726

Hierarchy Level | 726

Description | 727

Options | 727

Required Privilege Level | 727

Release Information | 728

Syntax

weight number;

Hierarchy Level

[edit chassis cluster redundancy-group group-number interface-


monitor interface ]
727

[edit chassis cluster redundancy-group group-number ip-monitoring IP–


address]

Description

Specify the relative importance of the object to the operation of the redundancy group. This statement
is primarily used with interface monitoring and IP address monitoring objects. The failure of an object—
such as an interface—with a greater weight brings the group closer to failover. Every monitored object is
assigned a weight.

• interface-monitor objects—If the object fails, its weight is deducted from the threshold of its
redundancy group;

• ip-monitoring objects—If a monitored IP address becomes unreachable for any reason, the weight
assigned to that monitored IP address is deducted from the redundancy group’s global-threshold for
IP address monitoring.

Every redundancy group has a default threshold of 255. If the threshold reaches 0, a failover is triggered.
Failover is triggered even if the redundancy group is in manual failover mode and preemption is not
enabled.

Options

number —Weight assigned to the interface or monitored IP address. A higher weight value indicates a
greater importance.

• Range: 0 through 255

Required Privilege Level

interface—To view this statement in the configuration.

interface-control—To add this statement to the configuration.


728

Release Information

Statement modified in Junos OS Release 10.1.

RELATED DOCUMENTATION

cluster (Chassis) | 606


8 CHAPTER

Operational Commands

clear chassis cluster control-plane statistics | 732

clear chassis cluster data-plane statistics | 733

clear chassis cluster failover-count | 735

clear chassis cluster ip-monitoring failure-count | 737

clear chassis cluster ip monitoring failure count ip address | 739

clear chassis cluster statistics | 741

request chassis cb | 742

request chassis cluster configuration-synchronize | 745

request chassis cluster failover node | 746

request chassis cluster failover redundancy-group | 748

request chassis cluster failover reset | 750

request chassis fpc | 752

request chassis fpc-control-port | 755

request chassis cluster in-service-upgrade abort (ISSU) | 757

request chassis primary-ha-control-port-transition | 759

request security internal-security-association refresh | 761

request system scripts add | 763

request system reboot (SRX Series) | 768

request system software in-service-upgrade (Maintenance) | 770

OBSOLETE: request system software rollback (SRX Series) | 776


set chassis cluster disable reboot | 778

set chassis cluster cluster-id node node-number reboot | 780

show chassis cluster control-plane statistics | 782

show chassis cluster data-plane interfaces | 786

show chassis cluster data-plane statistics | 788

show chassis cluster ethernet-switching interfaces | 791

show chassis cluster ethernet-switching status | 793

show chassis cluster information | 796

show chassis cluster information configuration-synchronization | 803

show chassis cluster information issu | 806

show chassis cluster interfaces | 808

show chassis cluster ip-monitoring status redundancy-group | 818

show chassis cluster statistics | 822

show chassis cluster status | 829

show chassis environment (Security) | 834

show chassis environment cb | 842

show chassis ethernet-switch | 847

show chassis fabric plane | 854

show chassis fabric plane-location | 862

show chassis fabric summary | 865

show chassis hardware (View) | 868

show chassis routing-engine (View) | 889

show chassis reswatch | 896

show chassis scb-ha-port | 898

show chassis temperature-thresholds | 903

show configuration chassis cluster traceoptions | 906

show interfaces (SRX Series) | 908

set date ntp | 957

show system ntp threshold | 959

show security macsec connections | 961

show security macsec statistics (SRX Series Firewalls) | 964

show security mka statistics | 970

show security mka sessions (SRX Series Device | 974

show security internal-security-association | 977


show system license (View) | 979

show vrrp | 984


732

clear chassis cluster control-plane statistics

IN THIS SECTION

Syntax | 732

Description | 732

Required Privilege Level | 732

Output Fields | 732

Sample Output | 733

Release Information | 733

Syntax

clear chassis cluster control-plane statistics

Description

Clear the control plane statistics of a chassis cluster.

Required Privilege Level

clear

Output Fields

When you enter this command, you are provided feedback on the status of your request.
733

Sample Output

clear chassis cluster control-plane statistics

user@host> clear chassis cluster control-plane statistics


Cleared control-plane statistics

Release Information

Command introduced in Junos OS Release 9.3.

RELATED DOCUMENTATION

show chassis cluster control-plane statistics | 782

clear chassis cluster data-plane statistics

IN THIS SECTION

Syntax | 734

Description | 734

Required Privilege Level | 734

Output Fields | 734

Sample Output | 734

Release Information | 734


734

Syntax

clear chassis cluster data-plane statistics

Description

Clear the data plane statistics of a chassis cluster.

Required Privilege Level

clear

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

clear chassis cluster data-plane statistics

user@host> clear chassis cluster data-plane statistics


Cleared data-plane statistics

Release Information

Command introduced in Junos OS Release 9.3.


735

RELATED DOCUMENTATION

show chassis cluster data-plane statistics | 788

clear chassis cluster failover-count

IN THIS SECTION

Syntax | 735

Description | 735

Required Privilege Level | 735

Output Fields | 736

Sample Output | 736

Release Information | 737

Syntax

clear chassis cluster failover-count

Description

Clear the failover count of all redundancy groups.

Required Privilege Level

clear
736

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

The following example displays the redundancy groups before and after the failover-counts are cleared.

show chassis cluster status

user@host> show chassis cluster status

Cluster ID: 3
Node name Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 1


node0 200 secondary no no
node1 100 primary no no

Redundancy group: 1 , Failover count: 2


node0 100 primary no no
node1 10 secondary no no

clear chassis cluster failover-count

user@host> clear chassis cluster failover-count


Cleared failover-count for all redundancy-groups

show chassis cluster status

user@host> show chassis cluster status

Cluster ID: 3
Node name Priority Status Preempt Manual failover

Redundancy group: 0 , Failover count: 0


737

node0 200 secondary no no


node1 100 primary no no

Redundancy group: 1 , Failover count: 0


node0 100 primary no no
node1 10 secondary no no

Release Information

Command introduced in Junos OS Release 9.3.

RELATED DOCUMENTATION

request chassis cluster failover node | 746


request chassis cluster failover reset | 750
show chassis cluster status | 829

clear chassis cluster ip-monitoring failure-count

IN THIS SECTION

Syntax | 738

Description | 738

Required Privilege Level | 738

Output Fields | 738

Sample Output | 738

Release Information | 739


738

Syntax

clear chassis cluster ip-monitoring failure-count

Description

Clear the failure count for all IP addresses.

Required Privilege Level

clear

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

user@host> clear chassis cluster ip-monitoring failure-count

command-name

node0:
--------------------------------------------------------------------------
Cleared failure count for all IPs

node1:
--------------------------------------------------------------------------
Cleared failure count for all IPs
739

Release Information

Command introduced in Junos OS Release 10.1.

RELATED DOCUMENTATION

clear chassis cluster ip monitoring failure count ip address | 739

clear chassis cluster ip monitoring failure count ip


address

IN THIS SECTION

Syntax | 739

Description | 739

Required Privilege Level | 740

Output Fields | 740

Sample Output | 740

Release Information | 740

Syntax

clear chassis cluster ip-monitoring failure-count ip-address IP-address

Description

Clear the failure count for a specified IP address.


740

NOTE: Entering an IP address at the end of this command is optional. If you do not specify an IP
address, the failure count for all monitored IP addresses is cleared.

Required Privilege Level

clear

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

user@host> clear chassis cluster ip-monitoring failure-count ip-address 10.1.1.1

clear chassis cluster ip-monitoring failure-count ip-address 10.1.1.1

node0:
--------------------------------------------------------------------------
Cleared failure count for IP: 10.1.1.1

node1:
--------------------------------------------------------------------------
Cleared failure count for IP: 10.1.1.1

Release Information

Command introduced in Junos OS Release 10.1.


741

RELATED DOCUMENTATION

clear chassis cluster failover-count | 735


clear chassis cluster ip-monitoring failure-count | 737

clear chassis cluster statistics

IN THIS SECTION

Syntax | 741

Description | 741

Required Privilege Level | 741

Output Fields | 742

Sample Output | 742

Release Information | 742

Syntax

clear chassis cluster statistics

Description

Clear the control plane and data plane statistics of a chassis cluster.

Required Privilege Level

clear
742

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

clear chassis cluster statistics

user@host> clear chassis cluster statistics


Cleared control-plane statistics
Cleared data-plane statistics

Release Information

Command introduced in Junos OS Release 9.3.

RELATED DOCUMENTATION

show chassis cluster statistics | 822

request chassis cb

IN THIS SECTION

Syntax | 743

Description | 743

Options | 743

Required Privilege Level | 743

Output Fields | 743


743

Sample Output | 744

Release Information | 744

Syntax

request chassis cb (offline | online) slot slot-number

Description

Control the operation (take the CB offline or bring online) of the Control Board (CB).

Options

offline Take the Control Board offline.

online Bring the Control Board online.

slot slot-number Control Board slot number.

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request.
744

Sample Output

request chassis cb (SRX Series)

user@host> request chassis cb offline slot 2 node local


node0:
--------------------------------------------------------------------------
Offline initiated, use "show chassis environment cb" to verify

request chassis cb (PTX10008 Router)

user@host> request chassis cb offline slot 1


Offline initiated, use "show chassis environment cb" to verify

Release Information

Command introduced in Junos OS Release 9.2.

Starting with Junos OS Release 12.1X47-D15, the SRX5K-SCBE (SCB2) is introduced and starting with
Junos OS Release 15.1X49-D10, the SRX5K-SCB3 (SCB3) with enhanced midplane is introduced.

RELATED DOCUMENTATION

show chassis environment cb | 842


745

request chassis cluster configuration-synchronize

IN THIS SECTION

Syntax | 745

Description | 745

Required Privilege Level | 745

Output Fields | 745

Sample Output | 746

Release Information | 746

Syntax

request chassis cluster configuration-synchronize

Description

On the primary node , you can synchronize the configuration from the primary node to the secondary
node when the secondary node joins the primary node in a cluster.

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request.
746

Sample Output

request chassis cluster configuration-synchronize

{primary:node0}
user@host> request chassis cluster configuration-synchronize
Performing configuration synchronization from remote node.

Release Information

Command introduced in Junos OS Release 12.1X47-D10.

RELATED DOCUMENTATION

Understanding Automatic Chassis Cluster Synchronization Between Primary and Secondary Nodes |
151
Verifying Chassis Cluster Configuration Synchronization Status | 152
NTP Time Synchronization on SRX Series Devices | 360

request chassis cluster failover node

IN THIS SECTION

Syntax | 747

Description | 747

Options | 747

Required Privilege Level | 747

Output Fields | 748

Sample Output | 748


747

Release Information | 748

Syntax

request chassis cluster failover node node-number


redundancy-group group-number

Description

For chassis cluster configurations, initiate manual failover in a redundancy group from one node to the
other, which becomes the primary node, and automatically reset the priority of the group to 255. The
failover stays in effect until the new primary node becomes unavailable, the threshold of the redundancy
group reaches 0, or you use the request chassis cluster failover reset command.

After a manual failover, you must use the request chassis cluster failover reset command before initiating
another failover.

Options

• node node-number—Number of the chassis cluster node to which the redundancy group fails over.

• Range: 0 through 1

• redundancy-group group-number—Number of the redundancy group on which to initiate manual failover.


Redundancy group 0 is a special group consisting of the two Routing Engines in the chassis cluster.

Range: 0 through 255

Required Privilege Level

maintenance
748

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis cluster failover node

user@host> request chassis cluster failover node 0 redundancy-group 1


Initiated manual failover for redundancy group 1

Release Information

Command introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

clear chassis cluster failover-count | 735


request chassis cluster failover reset | 750
show chassis cluster status | 829

request chassis cluster failover redundancy-group

IN THIS SECTION

Syntax | 749

Description | 749

Options | 749

Required Privilege Level | 749


749

Output Fields | 750

Sample Output | 750

Release Information | 750

Syntax

request chassis cluster failover node node-number redundancy-group redundancy-group-number

Description

For chassis cluster configurations, initiate manual failover in a redundancy group from one node to the
other, which becomes the primary node, and automatically reset the priority of the group to 255. The
failover stays in effect until the new primary node becomes unavailable, the threshold of the redundancy
group reaches 0, or you use the request chassis cluster failover reset command.

After a manual failover, you must use the request chassis cluster failover reset command before initiating
another failover.

Options

• node node-number—Number of the chassis cluster node to which the redundancy group fails over.

• Range: 0 or 1

• redundancy-group group-number—Number of the redundancy group on which to initiate manual failover.


Redundancy group 0 is a special group consisting of the two Routing Engines in the chassis cluster.

Range: 0 through 255

Required Privilege Level

maintenance
750

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis cluster failover redundancy-group

user@host> request chassis cluster failover redundancy-group 0 node 1


{primary:node0}
user@host> request chassis cluster failover redundancy-group 0 node 1
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Initiated manual failover for redundancy group 0

Release Information

Command introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

Initiating a Chassis Cluster Manual Redundancy Group Failover | 289


Verifying Chassis Cluster Failover Status | 294

request chassis cluster failover reset

IN THIS SECTION

Syntax | 751

Description | 751
751

Options | 751

Required Privilege Level | 751

Output Fields | 752

Sample Output | 752

Release Information | 752

Syntax

request chassis cluster failover reset


redundancy-group group-number

Description

In chassis cluster configurations, undo the previous manual failover and return the redundancy group to
its original settings.

Options

redundancy-group group-number—Number of the redundancy group on which to reset manual failover.


Redundancy group 0 is a special group consisting of the two Routing Engines in the chassis cluster.

Range: 0 through 255

Required Privilege Level

maintenance
752

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis cluster failover reset

user@host> request chassis cluster failover reset redundancy-group 0

Release Information

Command introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

clear chassis cluster failover-count | 735


request chassis cluster failover node | 746
show chassis cluster status | 829

request chassis fpc

IN THIS SECTION

Syntax | 753

Description | 753

Options | 753

Required Privilege Level | 754

Output Fields | 754


753

Sample Output | 754

Release Information | 754

Syntax

request chassis fpc


<node (node-id | local | primary)>
<offline | online | restart>
<slot slot-number>

Description

Control the operation of the Flexible PIC Concentrator (FPC).

NOTE: The SRX5K-SPC-2-10-40 (SPC1), SRX5K-SPC-4-15-320 (SPC2), and SRX5K-SPC3 does


not support the request chassis fpc command.

Options

node Change Flexible PIC Concentrator status of specific node.

offline Take the FPC or PFE-instance offline.

online Bring the FPC or PFE-instance online.

restart Restart the FPC or PFE-instance.

slot slot-number Specify the FPC slot number.


754

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis fpc (SRX Series)

user@host> request chassis fpc online slot 0


FPC 0 already online

Release Information

Command modified in Junos OS Release 9.2.

Command introduced in Junos OS Release 17.2.

RELATED DOCUMENTATION

show chassis fpc (View)


755

request chassis fpc-control-port

IN THIS SECTION

Syntax | 755

Description | 755

Options | 755

Required Privilege Level | 756

Output Fields | 756

Sample Output | 756

Release Information | 756

Syntax

request chassis fpc-control-port (disable | enable) fpc FPC slot number port Port number

Description

You can disable FPC HA control port 0 on primary node and enable FPC HA control port 0 on secondary
node.

Options

disable Disable HA control port on the local node.

enable Enable HA control port on the local node.

fpc Specify the fpc slot number.

Range: 0 through 23
756

port Specify the port number.

Range: 0 through 1

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis fpc-control-port

user@host> request chassis fpc-control-port disable fpc 0 port 0

fpc 0 HA port 0 disabled

user@host> request chassis fpc-control-port enable fpc 0 port 0

fpc 0 HA port 0 enabled

Release Information

Command introduced in Junos OS Release 21.4R1.


757

RELATED DOCUMENTATION

Chassis Cluster Dual Control Links | 172

request chassis cluster in-service-upgrade abort


(ISSU)

IN THIS SECTION

Syntax | 757

Description | 757

Options | 758

Required Privilege Level | 758

Output Fields | 758

Sample Output | 758

Release Information | 758

Syntax

request chassis cluster in-service-upgrade abort

Description

Terminate an upgrade in a chassis cluster during an in-service software upgrade (ISSU). Use this
command to end the ISSU on any nodes in a chassis cluster followed by reboot to terminate the ISSU on
that device.
758

Options

This command has no options.

Required Privilege Level

view

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis cluster in-service-upgrade terminate

user@host> request chassis cluster in-service-upgrade abort


Exiting in-service-upgrade window
Chassis ISSU Aborted

Release Information

Command introduced in Junos OS Release 11.2.

RELATED DOCUMENTATION

Upgrading a Chassis Cluster Using In-Service Software Upgrade | 514


759

request chassis primary-ha-control-port-transition

IN THIS SECTION

Syntax | 759

Description | 759

Options | 759

Required Privilege Level | 760

Output Fields | 760

Sample Output | 760

Release Information | 761

Syntax

request chassis primary-ha-control-port-transition <fpc FPC slot number | from-fpc-to-scb | from-


scb-to-fpc>

Description

With this command, you can disable the FPC slot number HA port 0 on local node, and then enable the
SCB0 HA control port on local node or disable the SCB0 HA control port on local node, and then enable
the FPC slot number HA port 0 on local node.

This command is used during single control link online transition and it can be carried out in cluster
mode on SRX5K series devices.

Options

fpc Specify the FPC slot number.


760

Range: 0 through 23

from-fpc-to-scb Transition from FPC to SCB.

from-scb-to-fpc Transition from SCB to FPC.

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request chassis primary-ha-control-port-transition

user@host> request chassis primary-ha-control-port-transition from-fpc-to-scb fpc 0

fpc 0 HA control port 0 disabled & scb 0 HA control port enabled

user@host> request chassis primary-ha-control-port-transition from-scb-to-fpc fpc 0

scb 0 HA control port disabled & fpc 0 HA control port 0 enabled


761

Release Information

Command introduced in Junos OS Release 21.4R1.

RELATED DOCUMENTATION

Chassis Cluster Dual Control Links | 172

request security internal-security-association


refresh

IN THIS SECTION

Syntax | 761

Description | 761

Required Privilege Level | 762

Output Fields | 762

Sample Output | 762

Release Information | 763

Syntax

request security internal-security-association refresh node <node-id | all | local | primary>

Description

Activate internal IPsec so an attacker cannot gain unauthorized information.


762

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request. Table 40 on
page 762 shows the list of output fields.

Table 40: request security internal-security-association refresh Output Fields

Field Name Field Description

RE Specify key for the routing engine.

direction Direction of the manual security association. The direction must be bidirectional.

Sample Output

request security internal-security-association refresh

with security ipsec internal security-association enabled

user@host> request security internal-security-association refresh


node0:
--------------------------------------------------------------------------
RE: set up internal sa

node1:
--------------------------------------------------------------------------
RE: set up internal sa
763

with security ipsec internal security-association disabled

user@host> request security internal-security-association refresh


node0:
--------------------------------------------------------------------------
RE: no key
direction 0
delete __juniper_internal_ipsec_sa__, direction 0
direction 1
delete __juniper_internal_ipsec_sa__, direction 1

node1:
--------------------------------------------------------------------------
RE: no key
direction 0
delete __juniper_internal_ipsec_sa__, direction 0
direction 1
delete __juniper_internal_ipsec_sa__, direction 1

Release Information

Command introduced in Junos OS Release 12.1X45-D10.

RELATED DOCUMENTATION

show security internal-security-association | 977


internal (Security IPsec)

request system scripts add

IN THIS SECTION

Syntax | 764
764

Description | 764

Options | 764

Additional Information | 765

Required Privilege Level | 765

Sample Output | 765

Release Information | 768

Syntax

request system scripts add package-name <no-copy | unlink>


<master>
<backup>

Description

CLI command to install AI-Script install packages on SRX Series Firewalls in a chassis cluster.

Options

package-name Specify AI-Script install package name.

no-copy (Optional) Do not save a copy of the AI script package file.

unlink (Optional) Remove the AI script package after successful installation.

master (Optional) Install AI script packages on the primary node.

backup (Optional) Install AI script packages on the secondary node.


765

Additional Information

This command eliminates the AI script installation on both primary node and secondary node separately.

Required Privilege Level

maintenance

Sample Output

request system scripts add package-name

user@host> request system scripts add jais-5.0R1.0-signed.tgz master

[: -a: unexpected operator


grep: /etc/db/pkg/jais/+COMMENT: No such file or directory
Installing package '/var/tmp/jais-5.0R4.0-signed.tgz' ...
Verified jais-5.0R4.0.tgz signed by PackageProductionRSA_2016
Adding jais...
Available space: 798414 require: 1814
Installing AI-Scripts version: 5.0R4
Saving package file in /var/db/scripts/commit/jais-5.0R4.0-signed.tgz ...
NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.pre-install
ln: ///etc/rc.d/ais: Read-only file system
Model: srx5600
Model: srx5600
Linking in Junos ES manifest file.
Creating srx5800/srx5600 trend data file.
Creating SRX intelligence attachments file.
Creating SRX events attachments file.
Creating AI-Scripts FIFO
Starting AI-Scripts FIFO handler
77834: old priority 0, new priority 20
77842: old priority 0, new priority 20
RSI parameters are now being set
BIOS validation parameter is now being set
766

BIOS interval parameter is now being set


JMB cleanup age is now being set
JMB Event file is now being set
JMB User Event file is now being set
PHDC collect parameter is now being set
PHDC duration parameter is now being set
PHDC commands file is now being set
JMB Progress Logging parameter is now being set
iJMB generation parameters are now being set
AI-Scripts platform support flag is now being set
Interval event commands file is now being set
Interval event enabled parameter is now being set
All node log collect parameter is now being set
Disk Warning Threshold is now being set
Disk Full Threshold is now being set
RSI Lite Enabled is now being set
Removing any old files that need to be updated
Copying updated files
Restarting eventd ...
Event processing process started, pid 78147
Installation completed
Saving package file in /var/sw/pkg/jais-5.0R4.0-signed.tgz ...
Saving state for rollback ...

request system scripts add package-name

user@host> request system scripts add jais-5.0R1.0-signed.tgz backup


Pushing bundle to node1
[: -a: unexpected operator
grep: /etc/db/pkg/jais/+COMMENT: No such file or directory
Installing package '/var/tmp/jais-5.0R4.0-signed.tgz' ...
Verified jais-5.0R4.0.tgz signed by PackageProductionRSA_2016
Adding jais...
Available space: 2619677 require: 1814
Installing AI-Scripts version: 5.0R4
chmod: /var/db/scripts/event/cron.slax: No such file or directory
chmod: /var/db/scripts/event/bit_event.slax: No such file or directory
chmod: /var/db/scripts/event/bit_event2.slax: No such file or directory
chmod: /var/db/scripts/op/ais_bit.slax: No such file or directory
Saving package file in /var/db/scripts/commit/jais-5.0R4.0-signed.tgz ...
NOTICE: uncommitted changes have been saved in /var/db/config/juniper.conf.pre-install
767

ln: ///etc/rc.d/ais: Read-only file system


Mounted jais package on /dev/md2...
Verified manifest signed by PackageProductionRSA_2016
Verified jais-5.0R4.0 signed by PackageProductionRSA_2016
Model: srx5600
Model: srx5600
Linking in Junos ES manifest file.
Creating srx5800/srx5600 trend data file.
Creating SRX intelligence attachments file.
Creating SRX events attachments file.
Creating AI-Scripts FIFO
Starting AI-Scripts FIFO handler
99423: old priority 0, new priority 20
99428: old priority 0, new priority 20
99429: old priority 0, new priority 20
99430: old priority 0, new priority 20
RSI parameters are now being set
BIOS validation parameter is now being set
BIOS interval parameter is now being set
JMB cleanup age is now being set
JMB Event file is now being set
JMB User Event file is now being set
PHDC collect parameter is now being set
PHDC duration parameter is now being set
PHDC commands file is now being set
JMB Progress Logging parameter is now being set
iJMB generation parameters are now being set
AI-Scripts platform support flag is now being set
Interval event commands file is now being set
Interval event enabled parameter is now being set
All node log collect parameter is now being set
Disk Warning Threshold is now being set
Disk Full Threshold is now being set
RSI Lite Enabled is now being set
chmod: /var/db/scripts/event/cron.slax: No such file or directory
chmod: /var/db/scripts/event/bit_event.slax: No such file or directory
chmod: /var/db/scripts/event/bit_event2.slax: No such file or directory
chmod: /var/db/scripts/op/ais_bit.slax: No such file or directory
Removing any old files that need to be updated
Copying updated files
Restarting eventd ...
Event processing process started, pid 99730
Installation completed
768

Saving package file in /var/sw/pkg/jais-5.0R4.0-signed.tgz ...


Saving state for rollback ...

Release Information

Command introduced before Junos OS Release 9.0. The options master and backup are introduced in Junos
OS Release 15.1X49-D50.

RELATED DOCUMENTATION

Understanding Automatic Chassis Cluster Synchronization Between Primary and Secondary Nodes |
151

request system reboot (SRX Series)

IN THIS SECTION

Syntax | 768

Description | 769

Options | 769

Required Privilege Level | 769

Release Information | 770

Syntax

request system reboot <at time> <in minutes><media><message “text”>


769

Description

Reboot the software.

Options

• at time (Optional)— Specify the time at which to reboot the device. You can specify time in one of
the following ways:

• now— Reboot the device immediately. This is the default.

• +minutes— Reboot the device in the number of minutes from now that you specify.

• yymmddhhmm— Reboot the device at the absolute time on the date you specify. Enter the year,
month, day, hour (in 24-hour format), and minute.

• hh:mm— Reboot the device at the absolute time you specify, on the current day. Enter the time in
24-hour format, using a colon (:) to separate hours from minutes.

• in minutes(Optional)— Specify the number of minutes from now to reboot the device. This option is a
synonym for the at +minutes option

• media type(Optional)— Specify the boot device to boot the device from:

• disk/internal— Reboot from the internal media. This is the default.

• usb— Reboot from the USB storage device.

• compact flash— Reboot from the external CompactFlash card.

NOTE: The media command option is not available on vSRX Virtual Firewall.

• message “text” (Optional)— Provide a message to display to all system users before the device
reboots.

Example: request system reboot at 5 in 50 media internal message stop

Required Privilege Level

maintenance
770

Release Information

Command introduced in Junos OS Release 10.1.

Command hypervisor option introduced in Junos OS Release 15.1X49-D10 for vSRX Virtual Firewall.

RELATED DOCUMENTATION

request system software rollback (SRX Series)

request system software in-service-upgrade


(Maintenance)

IN THIS SECTION

Syntax | 770

Description | 771

Options | 771

Required Privilege Level | 772

Output Fields | 772

Sample Output | 772

Sample Output | 773

Release Information | 775

Syntax

request system software in-service-upgrade image_name


<no-copy>
<no-old-master-upgrade>
<no-sync>
<no-tcp-syn-check>
771

<no-validate>
<status>
<unlink>

Description

The in-service software upgrade (ISSU) feature allows a chassis cluster pair to be upgraded from
supported Junos OS versions with a traffic impact similar to that of redundancy group failovers. Before
upgrading, you must perform failovers so that all redundancy groups are active on only one device. We
recommend that graceful restart for routing protocols be enabled before you initiate an ISSU.

For SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX380 devices, you must use the no-sync
parameter to perform an in-band cluster upgrade (ICU). This allows a chassis cluster pair to be upgraded
with a minimal service disruption of approximately 30 seconds.

For SRX1500, SRX4100, and SRX4200 devices, the no-sync parameter is not supported when using ISSU
to upgrade. The no-sync option specifies that the state is not synchronized from the primary node to the
secondary node.

For SRX1500 devices, the no-tcp-syn-check parameter is not supported when using ISSU to upgrade.

Options

• image_name—Specify the location and name of the software upgrade package to be installed.

• no-copy—(Optional) Install the software upgrade package but do not save the copies of package files.

• no-old-master-upgrade—(Optional) Do not upgrade the old primary after switchover.

This parameter applies to SRX5400, SRX5600, and SRX5800 devices only.

• no-sync—(Optional) Stop the flow state from synchronizing when the old secondary node has booted
with a new Junos OS image.

This parameter applies to SRX300, SRX320, SRX340, SRX345, SRX550M, and SRX380 devices only.
It is required for an ICU.

• no-tcp-syn-check—(Optional) Create a window wherein the TCP SYN check for the incoming packets is
disabled. The default value for the window is 7200 seconds (2 hours).

This parameter applies to SRX300, SRX320, SRX340, SRX345, SRX550M and SRX380 devices only.
772

• no-validate—(Optional) Disable the configuration validation step at installation. The system behavior is
similar to that of the request system software add command.

This parameter applies to SRX300, SRX320, SRX340, SRX345, SRX550M and SRX380 devices only.

• status—(Optional) Display the status of a unified ISSU during the upgrade. You will need to run this
command on the Routing Engine where the ISSU was triggered to display the correct ISSU log file.

This parameter applies to SRX1500, SRX4100, SRX4200, SRX4600, SRX5400, SRX5600, and
SRX5800 devices only.

• unlink—(Optional) Remove the software package after successful installation.

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

request system software in-service-upgrade status (SRX1500, SRX4100, SRX4200, SRX4600,


SRX5400, SRX5600, and SRX5800)

user@host> request system software in-service-upgrade status


[Apr 29 01:31:11]:ISSU: Validating Image
[Apr 29 01:43:13]:ISSU: Validating Image Done
[Apr 29 01:43:13]:ISSU: Preparing Backup RE
[Apr 29 01:43:13]:ISSU: Pushing /var/tmp/junos-install-mx-x86-32-19.3I20190425_1
100_divyansh.tgz to re1:/var/tmp/junos-install-mx-x86-32-19.3I20190425_1100_divy
ansh.tgz
[Apr 29 01:44:48]:ISSU: Pushing package /var/tmp/junos-install-mx-x86-32-19.3I20
190425_1100_divyansh.tgz to re1 done
[Apr 29 01:44:48]:ISSU: Installing package /var/tmp/junos-install-mx-x86-32-19.3
I20190425_1100_divyansh.tgz on re1
773

[Apr 29 01:52:35]:ISSU: Installing package /var/tmp/junos-install-mx-x86-32-19.3


I20190425_1100_divyansh.tgz on re1 done
[Apr 29 01:52:35]:ISSU: Rebooting Backup RE
[Apr 29 01:52:36]:ISSU: Backup RE Prepare Done
[Apr 29 01:52:36]:ISSU: Waiting for Backup RE reboot
[Apr 29 01:56:45]:ISSU: Backup RE reboot done. Backup RE is up
[Apr 29 01:56:45]:ISSU: Waiting for Backup RE state synchronization
[Apr 29 01:57:10]:ISSU: Backup RE state synchronization done
[Apr 29 01:57:10]:ISSU: GRES operational
[Apr 29 01:58:16]:ISSU: Preparing Daemons
[Apr 29 01:58:40]:ISSU: Daemons Ready for ISSU
[Apr 29 01:58:46]:ISSU: Offline Incompatible FRUs
[Apr 29 01:58:51]:ISSU: Starting Upgrade for FRUs
[Apr 29 02:03:32]:ISSU: Preparing for Switchover
[Apr 29 02:03:57]:ISSU: Ready for Switchover
[Apr 29 02:03:59]:ISSU: RE switchover Done
[Apr 29 02:03:59]:ISSU: Upgrading Old Master RE
[Apr 29 02:12:51]:ISSU: Old Master Upgrade Done
[Apr 29 02:12:51]:ISSU: IDLE

Sample Output

request system software in-service-upgrade (SRX300, SRX320, SRX340, SRX345, SRX550M,


and SRX380 Devices)

user@host> request system software in-service-upgrade /var/tmp/junos-srxsme-15.1I20160520_0757-


domestic.tgz no-sync

ISSU: Validating package


WARNING: in-service-upgrade shall reboot both the nodes
in your cluster. Please ignore any subsequent
reboot request message
ISSU: start downloading software package on secondary node
Pushing /var/tmp/junos-srxsme-15.1I20160520_0757-domestic.tgz to node0:/var/tmp/junos-
srxsme-15.1I20160520_0757-domestic.tgz
Formatting alternate root (/dev/da0s1a)...
/dev/da0s1a: 2510.1MB (5140780 sectors) block size 16384, fragment size 2048
using 14 cylinder groups of 183.62MB, 11752 blks, 23552 inodes.
super-block backups (for fsck -b #) at:
774

32, 376096, 752160, 1128224, 1504288, 1880352, 2256416, 2632480, 3008544,


3384608, 3760672, 4136736, 4512800, 4888864
Installing package '/altroot/cf/packages/install-tmp/junos-15.1I20160520_0757-domestic' ...
Verified junos-boot-srxsme-15.1I20160520_0757.tgz signed by PackageDevelopmentEc_2016 method
ECDSA256+SHA256
Verified junos-srxsme-15.1I20160520_0757-domestic signed by PackageDevelopmentEc_2016 method
ECDSA256+SHA256

WARNING: The software that is being installed has limited support.


WARNING: Run 'file show /etc/notices/unsupported.txt' for details.

Verified junos-boot-srxsme-15.1I20160520_0757.tgz signed by PackageDevelopmentEc_2016 method


ECDSA256+SHA256
Verified junos-srxsme-15.1I20160520_0757-domestic signed by PackageDevelopmentEc_2016 method
ECDSA256+SHA256
JUNOS 15.1I20160520_0757 will become active at next reboot
WARNING: A reboot is required to load this software correctly
WARNING: Use the 'request system reboot' command
WARNING: when software installation is complete
cp: cannot overwrite directory /altroot/cf/etc/ssh with non-directory /cf/etc/ssh
Saving state for rollback ...
ISSU: finished upgrading on secondary node node0
ISSU: start upgrading software package on primary node
Formatting alternate root (/dev/da0s1a)...
/dev/da0s1a: 2510.1MB (5140780 sectors) block size 16384, fragment size 2048
using 14 cylinder groups of 183.62MB, 11752 blks, 23552 inodes.
super-block backups (for fsck -b #) at:
32, 376096, 752160, 1128224, 1504288, 1880352, 2256416, 2632480, 3008544,
3384608, 3760672, 4136736, 4512800, 4888864
Installing package '/altroot/cf/packages/install-tmp/junos-15.1I20160520_0757-domestic' ...
Verified junos-boot-srxsme-15.1I20160520_0757.tgz signed by PackageDevelopmentEc_2016 method
ECDSA256+SHA256
Verified junos-srxsme-15.1I20160520_0757-domestic signed by PackageDevelopmentEc_2016 method
ECDSA256+SHA256

WARNING: The software that is being installed has limited support.


WARNING: Run 'file show /etc/notices/unsupported.txt' for details.

Verified junos-boot-srxsme-15.1I20160520_0757.tgz signed by PackageDevelopmentEc_2016 method


ECDSA256+SHA256
Verified junos-srxsme-15.1I20160520_0757-domestic signed by PackageDevelopmentEc_2016 method
ECDSA256+SHA256
JUNOS 15.1I20160520_0757 will become active at next reboot
775

WARNING: A reboot is required to load this software correctly


WARNING: Use the 'request system reboot' command
WARNING: when software installation is complete
cp: cannot overwrite directory /altroot/cf/etc/ssh with non-directory /cf/etc/ssh
Saving state for rollback ...
ISSU: failover all redundancy-groups 1...n to primary node
Successfully reset all redundancy-groups priority back to configured priority.
Successfully reset all redundancy-groups priority back to configured priority.
error: Command failed. None of the redundancy-groups has been failed over.
Some redundancy-groups' priority on node1 are 0.
e.g.: priority of redundancy-groups-1 on node1 is 0.
Use 'force' option at the end to ignore this check.
WARNING: Using force option may cause traffic loss.
ISSU: rebooting Secondary Node
Shutdown NOW!
ISSU: Waiting for secondary node node0 to reboot.
ISSU: node 0 went down
ISSU: Waiting for node 0 to come up
ISSU: node 0 came up
ISSU: secondary node node0 booted up.
ISSU: failover all redundancy-groups 1...n to remote node, before reboot.
Successfully reset all redundancy-groups priority back to configured priority.

Shutdown NOW!

{primary:node1}
user@host>
*** FINAL System shutdown message from user@host ***

System going down IMMEDIATELY

Release Information

For SRX5400, SRX5600, and SRX5800 devices, command introduced in Junos OS Release 9.6. For
SRX5400 devices, the command is introduced in Junos OS Release 12.1X46-D20. For SRX300, SRX320,
SRX340, and SRX345 devices, command introduced in Junos OS Release 15.1X49-D40. For SRX1500
devices, command introduced in Junos OS Release 15.1X49-D50. For SRX380 devices, command
introduced in Junos OS Release 20.1R1.
776

Starting with Junos OS Release 15.1X49-D80, SRX4100 and SRX4200 devices support ISSU.

Starting with Junos OS Release 17.4R1, SRX4600 devices support ISSU.

SRX300 Series devices, SRX550M devices and vSRX Virtual Firewall do not support ISSU.

For SRX1500, SRX4100, SRX4200, SRX4600, SRX5400, SRX5600, and SRX5800, the status option is
introduced in Junos OS Release 20.4R1.

RELATED DOCUMENTATION

request system software rollback (SRX Series)

OBSOLETE: request system software rollback (SRX


Series)

IN THIS SECTION

Syntax | 776

Description | 777

Options | 777

Required Privilege Level | 777

Release Information | 777

Syntax

request system software rollback <node-id>


777

Description

Use this command to revert to the software that was loaded at the last successful request system software
add command. The upgraded FreeBSD 11.x (supported in Junos OS Release 17.4R1) Junos OS image
provides an option to save a recovery image in an Operation, Administration, and Maintenance (OAM)
partition, but that option will save only the Junos OS image, not the Linux image. If a user saves the
Junos OS image and recovers it later, it might not be compatible with the Linux software loaded on the
system.

Options

node-id—Identification number of the chassis cluster node. It can be 0 or 1.

Required Privilege Level

maintenance

Release Information

Command introduced in Junos OS Release 10.1.

RELATED DOCUMENTATION

Upgrading Junos OS with Upgraded FreeBSD


Release Information for Junos OS with Upgraded FreeBSD
778

set chassis cluster disable reboot

IN THIS SECTION

Syntax | 778

Description | 778

Options | 778

Required Privilege Level | 779

Output Fields | 779

Sample Output | 779

Release Information | 779

Syntax

set chassis cluster disable <reboot>

Description

After defining chassis cluster configuration, you can disable or remove a chassis cluster and change the
SRX Series Firewalls to standalone devices by running the set chassis cluster disable reboot command
from the operational mode.

After the chassis cluster is disabled using this CLI command, you do not have a similar CLI option to
enable it.

Options

reboot You can disable the chassis cluster and run the reboot command. When the reboot is
completed, you can view the SRX device functioning in standalone mode.
779

Required Privilege Level

maintenance

Output Fields

Sample Output

set chassis cluster disable reboot

user@host> set chassis cluster disable reboot


Successfully disabled chassis cluster. Going to reboot now.

Release Information

Statement introduced in Junos OS Release 9.0.

RELATED DOCUMENTATION

set chassis cluster cluster-id node node-number reboot | 780


Disabling a Chassis Cluster | 536
780

set chassis cluster cluster-id node node-number


reboot

IN THIS SECTION

Syntax | 780

Description | 780

Options | 781

Required Privilege Level | 781

Output Fields | 781

Release Information | 781

Syntax

set chassis cluster cluster-id cluster-id node node-number reboot

Description

Sets the chassis cluster identifier (ID) and node ID on each device, and reboots the devices to enable
clustering. The system uses the chassis cluster ID and chassis cluster node ID to apply the correct
configuration for each node (for example, when you use the apply-groups command to configure the
chassis cluster management interface). The chassis cluster ID and node ID statements are written to the
EPROM, and the statements take effect when the system is rebooted.

Setting a cluster ID to 0 is equivalent to disabling a cluster. A cluster ID greater than 15 can only be set
when the fabric and control link interfaces are connected back-to-back.

NOTE: If you have a cluster set up and running with an earlier release of Junos OS, you can
upgrade to Junos OS Release 12.1X45-D10 or later and re-create a cluster with cluster IDs
781

greater than 16. If for any reason you decide to revert to the previous version of Junos OS that
did not support extended cluster IDs, the system comes up with standalone devices after you
reboot. If the cluster ID set is less than 16 and you roll back to a previous release, the system
comes back with the previous setup.

Options

cluster-id cluster-id Identifies the cluster within the Layer 2 domain.

• Range: 0 through 255

node node Identifies a node within a cluster.

• Range: 0 through 1

reboot reboot the specified devices to configure the chassis cluster.

Required Privilege Level

maintenance

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Release Information

Support for extended cluster identifiers (more than 15 identifiers) added in Junos OS Release 12.1X45-
D10.
782

RELATED DOCUMENTATION

Example: Setting the Chassis Cluster Node ID and Cluster ID


Understanding the Interconnect Logical System and Logical Tunnel Interfaces
Example: Configuring Logical Systems in an Active/Passive Chassis Cluster (Primary Administrators
Only)
Disabling a Chassis Cluster
set chassis cluster disable reboot

show chassis cluster control-plane statistics

IN THIS SECTION

Syntax | 782

Description | 782

Required Privilege Level | 783

Output Fields | 783

Sample Output | 784

Sample Output | 785

Sample Output | 785

Release Information | 785

Syntax

show chassis cluster control-plane statistics

Description

Display information about chassis cluster control plane statistics.


783

Required Privilege Level

view

Output Fields

Table 41 on page 783 lists the output fields for the show chassis cluster control-plane statistics
command. Output fields are listed in the approximate order in which they appear.

Table 41: show chassis cluster control-plane statistics Output Fields

Field Name Field Description

Control link statistics Statistics of the control link used by chassis cluster traffic. Statistics for Control
link 1 are displayed when you use dual control links (SRX5600 and SRX5800
devices only).

• Heartbeat packets sent—Number of heartbeat messages sent on the


control link.

• Heartbeat packets received—Number of heartbeat messages received on


the control link.

• Heartbeat packet errors—Number of heartbeat packets received with


errors on the control link.

Fabric link statistics Statistics of the fabric link used by chassis cluster traffic. Statistics for Child
Link 1 are displayed when you use dual fabric links.

• Probes sent—Number of probes sent on the fabric link.

• Probes received—Number of probes received on the fabric link.


784

Table 41: show chassis cluster control-plane statistics Output Fields (Continued)

Field Name Field Description

Switch fabric link statistics Statistics of the switch fabric link used by chassis cluster traffic.

• Probe state—State of the probe, UP or DOWN.

• Probes sent—Number of probes sent.

• Probes received—Number of probes received.

• Probe recv error —Error in receiving probe.

• Probe send error—Error in sending probe.

Sample Output

show chassis cluster control-plane statistics

user@host> show chassis cluster control-plane statistics


Control link statistics:
Control link 0:
Heartbeat packets sent: 11646
Heartbeat packets received: 8343
Heartbeat packet errors: 0
Fabric link statistics:
Child link 0
Probes sent: 11644
Probes received: 8266
Switch fabric link statistics:
Probe state : DOWN
Probes sent: 8145
Probes received: 8013
Probe recv errors: 0
Probe send errors: 0
785

Sample Output

Sample Output

show chassis cluster control-plane statistics (SRX5000 Line Devices)

user@host> show chassis cluster control-plane statistics


Control link statistics:
Control link 0:
Heartbeat packets sent: 2061982
Heartbeat packets received: 2060367
Heartbeat packet errors: 0
Control link 1:
Heartbeat packets sent: 2061982
Heartbeat packets received: 0
Heartbeat packet errors: 0
Fabric link statistics:
Child link 0
Probes sent: 3844342
Probes received: 3843841
Child link 1
Probes sent: 0
Probes received: 0

Release Information

Command introduced in Junos OS Release 9.3. Output changed to support dual control ports in Junos
OS Release 10.0.

RELATED DOCUMENTATION

clear chassis cluster control-plane statistics | 732


786

show chassis cluster data-plane interfaces

IN THIS SECTION

Syntax | 786

Description | 786

Required Privilege Level | 786

Output Fields | 786

Sample Output | 787

Release Information | 787

Syntax

show chassis cluster data-plane interfaces

Description

Display the status of the data plane interface (also known as a fabric interface) in a chassis cluster
configuration.

Required Privilege Level

view

Output Fields

Table 42 on page 787 lists the output fields for the show chassis cluster data-plane interfaces command.
Output fields are listed in the approximate order in which they appear.
787

Table 42: show chassis cluster data-plane interfaces Output Fields

Field Name Field Description

fab0/fab1 Name of the logical fabric interface.

• Name—Name of the physical Ethernet interface.

• Status—State of the fabric interface: up or down.

Sample Output

show chassis cluster data-plane interfaces

user@host> show chassis cluster data-plane interfaces


fab0:
Name Status
ge-2/1/9 up
ge-2/2/5 up
fab1:
Name Status
ge-8/1/9 up
ge-8/2/5 up

Release Information

Command introduced in Junos OS Release 10.2.

RELATED DOCUMENTATION

cluster (Chassis) | 606


788

show chassis cluster data-plane statistics

IN THIS SECTION

Syntax | 788

Description | 788

Required Privilege Level | 788

Output Fields | 788

Sample Output | 790

Release Information | 790

Syntax

show chassis cluster data-plane statistics

Description

Display information about chassis cluster data plane statistics.

Required Privilege Level

view

Output Fields

Table 43 on page 789 lists the output fields for the show chassis cluster data-plane statistics command.
Output fields are listed in the approximate order in which they appear.
789

Table 43: show chassis cluster data-plane statistics Output Fields

Field Name Field Description

Services Synchronized • Service name—Name of the service.

• Rtos sent—Number of runtime objects (RTOs) sent.

• Rtos received—Number of RTOs received.

• Translation context—Messages synchronizing Network Address Translation


(NAT) translation context.

• Incoming NAT—Messages synchronizing incoming Network Address


Translation (NAT) service.

• Resource manager—Messages synchronizing resource manager groups and


resources.

• Session create—Messages synchronizing session creation.

• Session close—Messages synchronizing session close.

• Session change—Messages synchronizing session change.

• Gate create—Messages synchronizing creation of pinholes (temporary


openings in the firewall).

• Session ageout refresh request—Messages synchronizing request session


after age-out.

• Session ageout refresh reply—Messages synchronizing reply session after


age-out.

• IPsec VPN—Messages synchronizing VPN session.

• Firewall user authentication—Messages synchronizing firewall user


authentication session.

• MGCP ALG—Messages synchronizing MGCP ALG sessions.

• H323 ALG—Messages synchronizing H.323 ALG sessions.

• SIP ALG—Messages synchronizing SIP ALG sessions.

• SCCP ALG—Messages synchronizing SCCP ALG sessions.


790

Table 43: show chassis cluster data-plane statistics Output Fields (Continued)

Field Name Field Description

• PPTP ALG—Messages synchronizing PPTP ALG sessions.

• RTSP ALG—Messages synchronizing RTSP ALG sessions.

Sample Output

show chassis cluster data-plane statistics

user@host> show chassis cluster data-plane statistics


Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
Session create 0 0
Session close 0 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPsec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RTSP ALG 0 0

Release Information

Command introduced in Junos OS Release 9.3.


791

RELATED DOCUMENTATION

clear chassis cluster data-plane statistics | 733

show chassis cluster ethernet-switching interfaces

IN THIS SECTION

Syntax | 791

Description | 791

Required Privilege Level | 791

Output Fields | 792

Sample Output | 792

Release Information | 792

Syntax

show chassis cluster ethernet-switching interfaces

Description

Display the status of the switch fabric interfaces (swfab interfaces) in a chassis cluster.

Required Privilege Level

view
792

Output Fields

Table 44 on page 792 lists the output fields for the show chassis cluster ethernet-switching interfaces
command. Output fields are listed in the approximate order in which they appear.

Table 44: show chassis cluster ethernet-switching interfaces Output Fields

Field Name Field Description

swfab switch fabric interface- Name of the switch fabric interface.


name
• Name—Name of the physical interface.

• Status—State of the switch fabric interface: up or down.

Sample Output

show chassis cluster ethernet-switching interfaces

user@host> show chassis cluster ethernet-switching interfaces


swfab0:
Name Status
ge-0/0/9 up
ge-0/0/10 up
swfab1:
Name Status
ge-7/0/9 up
ge-7/0/10 up

Release Information

Command introduced in Junos OS Release 11.1.


793

RELATED DOCUMENTATION

cluster (Chassis) | 606


Ethernet Switching User Guide

show chassis cluster ethernet-switching status

IN THIS SECTION

Syntax | 793

Description | 793

Required Privilege Level | 793

Output Fields | 794

Sample Output | 795

Release Information | 795

Syntax

show chassis cluster ethernet-switching status

Description

Display the Ethernet switching status of the chassis cluster.

Required Privilege Level

view
794

Output Fields

Table 45 on page 794 lists the output fields for the show chassis cluster ethernet-switching status
command. Output fields are listed in the approximate order in which they appear.

Table 45: show chassis cluster ethernet-switching status Output Fields

Field Name Field Description

Cluster ID ID number (1-255) of a cluster. Setting a cluster ID to 0 is equivalent to disabling a cluster. A


cluster ID greater than 15 can only be set when the fabric and control link interfaces are
connected back-to-back.

Redundancy-Group You can create up to 128 redundancy groups in the chassis cluster.

Node name Node (device) in the chassis cluster (node0 or node1).

Priority Assigned priority for the redundancy group on that node.

Status State of the redundancy group (Primary, Secondary, Lost, or Unavailable).

• Primary—Redundancy group is active and passing traffic.

• Secondary—Redundancy group is passive and not passing traffic.

• Lost—Node loses contact with the other node through the control link. Most likely to occur
when both nodes are in a cluster and there is a control link failure, one node cannot
exchange heartbeats, or when the other node is rebooted.

• Unavailable—Node has not received a single heartbeat over the control link from the other
node since the other node booted up. Most likely to occur when one node boots up before
the other node, or if only one node is present in the cluster.

Preempt • Yes: Primary Role can be preempted based on priority.

• No: Change in priority will not preempt primary role.

Manual failover • Yes: Primary Role is set manually through the CLI.

• No: Primary Role is not set manually through the CLI.


795

Sample Output

show chassis cluster ethernet-switching status

user@host> show chassis cluster ethernet-switching status

Monitor Failure codes:


CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 0


node0 1 primary no no None
node1 1 secondary no no None

Ethernet switching status:


Probe state is UP. Both nodes are in single ethernet switching domain(s).

Release Information

Command introduced in Junos OS Release 11.1.

RELATED DOCUMENTATION

cluster (Chassis) | 606


Ethernet Switching User Guide
796

show chassis cluster information

IN THIS SECTION

Syntax | 796

Description | 796

Required Privilege Level | 796

Output Fields | 797

Sample Output | 797

Sample Output | 799

Sample Output | 801

Release Information | 802

Syntax

show chassis cluster information

Description

Display chassis cluster messages. The messages indicate each node's health condition and details of the
monitored failure.

Required Privilege Level

view
797

Output Fields

Table 46 on page 797 lists the output fields for the show chassis cluster information command. Output
fields are listed in the approximate order in which they appear.

Table 46: show chassis cluster information Output Fields

Field Name Field Description

Node Node (device) in the chassis cluster (node0 or node1).

Redundancy Group Information • Redundancy Group—ID number (0 - 255) of a redundancy group in the
cluster.

• Current State—State of the redundancy group: primary, secondary, hold, or


secondary-hold.

• Weight—Relative importance of the redundancy group.

• Time—Time when the redundancy group changed the state.

• From—State of the redundancy group before the change.

• To—State of the redundancy group after the change.

• Reason—Reason for the change of state of the redundancy group.

Chassis cluster LED information • Current LED color—Current color state of the LED.

• Last LED change reason—Reason for change of state of the LED.

Sample Output

show chassis cluster information

user@host> show chassis cluster information

node0:
--------------------------------------------------------------------------
798

Redundancy Group Information:

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


Mar 27 17:44:19 hold secondary Hold timer expired
Mar 27 17:44:27 secondary primary Better priority (200/200)

Redundancy Group 1 , Current State: primary, Weight: 255

Time From To Reason


Mar 27 17:44:19 hold secondary Hold timer expired
Mar 27 17:44:27 secondary primary Remote yield (0/0)

Redundancy Group 2 , Current State: secondary, Weight: 255

Time From To Reason


Mar 27 17:44:19 hold secondary Hold timer expired
Mar 27 17:44:27 secondary primary Remote yield (0/0)
Mar 27 17:50:24 primary secondary-hold Preempt/yield(100/200)
Mar 27 17:50:25 secondary-hold secondary Ready to become secondary

Chassis cluster LED information:


Current LED color: Green
Last LED change reason: No failures

node1:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255

Time From To Reason


Mar 27 17:44:27 hold secondary Hold timer expired

Redundancy Group 1 , Current State: secondary, Weight: 255

Time From To Reason


Mar 27 17:44:27 hold secondary Hold timer expired
Mar 27 17:50:23 secondary primary Remote yield (100/0)
Mar 27 17:50:24 primary secondary-hold Preempt/yield(100/200)
Mar 27 17:50:25 secondary-hold secondary Ready to become secondary
799

Redundancy Group 2 , Current State: primary, Weight: 255

Time From To Reason


Mar 27 17:44:27 hold secondary Hold timer expired
Mar 27 17:50:23 secondary primary Remote yield (200/0)

Chassis cluster LED information:


Current LED color: Green
Last LED change reason: No failures

Sample Output

show chassis cluster information (Monitoring Abnormal Case)

user@host> show chassis cluster information

The following output is specific to monitoring abnormal (unhealthy) case.

node0:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255

Time From To Reason


Apr 1 11:07:38 hold secondary Hold timer expired
Apr 1 11:07:41 secondary primary Only node present
Apr 1 11:29:20 primary secondary-hold Manual failover
Apr 1 11:34:20 secondary-hold secondary Ready to become secondary

Redundancy Group 1 , Current State: primary, Weight: 0

Time From To Reason


Apr 1 11:07:38 hold secondary Hold timer expired
Apr 1 11:07:41 secondary primary Only node present

Redundancy Group 2 , Current State: primary, Weight: 255


800

Time From To Reason


Apr 1 11:07:38 hold secondary Hold timer expired
Apr 1 11:07:41 secondary primary Only node present

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down

Failure Information:

IP Monitoring Failure Information:


Redundancy Group 1, Monitoring Status: Failed
IP Address Status Reason
10.1.1.1 Unreachable redundancy-group state unknown

node1:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


Apr 1 11:08:40 hold secondary Hold timer expired
Apr 1 11:29:20 secondary primary Remote is in secondary hold

Redundancy Group 1 , Current State: secondary, Weight: 0

Time From To Reason


Apr 1 11:08:40 hold secondary Hold timer expired

Redundancy Group 2 , Current State: secondary, Weight: 255

Time From To Reason


Apr 1 11:08:40 hold secondary Hold timer expired

Chassis cluster LED information:


Current LED color: Amber
Last LED change reason: Monitored objects are down

Failure Information:

IP Monitoring Failure Information:


801

Redundancy Group 1, Monitoring Status: Failed


IP Address Status Reason
10.1.1.1 Unreachable redundancy-group state unknown

Sample Output

show chassis cluster information (Preempt Delay Timer)

user@host> show chassis cluster information

node0:
--------------------------------------------------------------------------
Redundancy Group Information:

Redundancy Group 0 , Current State: secondary, Weight: 255

Time From To Reason


Aug 4 12:30:02 hold secondary Hold timer expired
Aug 4 12:30:05 secondary primary Only node present
Aug 4 14:19:58 primary secondary-hold Manual failover
Aug 4 14:24:58 secondary-hold secondary Ready to become secondary

Redundancy Group 1 , Current State: secondary, Weight: 255

Time From To Reason


Aug 4 14:07:57 secondary primary Remote is in secondary hold
Aug 4 14:20:23 primary secondary-hold Monitor failed: IF
Aug 4 14:20:24 secondary-hold secondary Ready to become secondary
Aug 4 14:20:54 secondary primary Remote is in secondary hold
Aug 4 14:21:30 primary secondary-hold Monitor failed: IF
Aug 4 14:21:31 secondary-hold secondary Ready to become secondary

Chassis cluster LED information:


Current LED color: Green
Last LED change reason: No failures

node1:
--------------------------------------------------------------------------
Redundancy Group Information:
802

Redundancy Group 0 , Current State: primary, Weight: 255

Time From To Reason


Aug 4 12:33:47 hold secondary Hold timer expired
Aug 4 14:19:57 secondary primary Remote is in secondary hold

Redundancy Group 1 , Current State: primary, Weight: 255

Time From To Reason


Aug 4 14:07:56 secondary-hold secondary Ready to become secondary
Aug 4 14:20:22 secondary primary Remote is in secondary hold
Aug 4 14:20:37 primary primary-preempt-hold Preempt (99/101)
Aug 4 14:20:52 primary-preempt-hold secondary-hold Primary preempt hold timer e
Aug 4 14:20:53 secondary-hold secondary Ready to become secondary
Aug 4 14:21:28 secondary primary Remote yield (99/0)

Chassis cluster LED information:


Current LED color: Green
Last LED change reason: No failures

Release Information

Command introduced in Junos OS Release 12.1X47-D10.

RELATED DOCUMENTATION

show chassis cluster status | 829


803

show chassis cluster information configuration-


synchronization

IN THIS SECTION

Syntax | 803

Description | 803

Required Privilege Level | 803

Output Fields | 804

Sample Output | 804

Release Information | 805

Syntax

show chassis cluster information configuration-synchronization

Description

Display chassis cluster messages. The messages indicate the redundancy mode, automatic
synchronization status, and if automatic synchronization is enabled on the device.

Required Privilege Level

view
804

Output Fields

Table 47 on page 804 lists the output fields for the show chassis cluster information configuration-
synchronization command. Output fields are listed in the approximate order in which they appear.

Table 47: show chassis cluster information configuration-synchronization Output Fields

Field Name Field Description

Node name Node (device) in the chassis cluster (node0 or node1).

Status • Activation status—State of automatic configuration synchronization:


Enabled or Disabled.

• Last sync operation—Status of the last synchronization.

• Last sync result—Result of the last synchronization.

• Last sync mgd messages—Management daemon messages of the last


synchronization.

Events The timestamp of the event, the automatic configuration synchronization


status, and the number of synchronization attempts.

Sample Output

show chassis cluster information configuration-synchronization

user@host> show chassis cluster information configuration-synchronization

node0:
--------------------------------------------------------------------------
Configuration Synchronization:
Status:
Activation status: Enabled
Last sync operation: Auto-Sync
Last sync result: Not needed
Last sync mgd messages:
805

Events:
Feb 25 22:21:49.174 : Auto-Sync: Not needed
node1:
--------------------------------------------------------------------------
Configuration Synchronization:
Status:
Activation status: Enabled
Last sync operation: Auto-Sync
Last sync result: Succeeded
Last sync mgd messages:
mgd: rcp: /config/juniper.conf: No such file or directory
Network security daemon: warning: You have enabled/disabled inet6
flow.
Network security daemon: You must reboot the system for your change
to take effect.
Network security daemon: If you have deployed a cluster, be sure to
reboot all nodes.
mgd: commit complete
Events:
Feb 25 23:02:33.467 : Auto-Sync: In progress. Attempt: 1
Feb 25 23:03:13.200 : Auto-Sync: Succeeded. Attempt: 1

Release Information

Command introduced in Junos OS Release 12.1X47-D10.

RELATED DOCUMENTATION

Understanding Automatic Chassis Cluster Synchronization Between Primary and Secondary Nodes |
151
NTP Time Synchronization on SRX Series Devices | 360
Example: Simplifying Network Management by Synchronizing the Primary and Backup Nodes with
NTP | 360
request chassis cluster configuration-synchronize | 745
806

show chassis cluster information issu

IN THIS SECTION

Syntax | 806

Description | 806

Required Privilege Level | 806

Output Fields | 806

Sample Output | 807

Release Information | 808

Syntax

show chassis cluster information issu

Description

Display chassis cluster messages. The messages indicate the progress of the in-service software upgrade
(ISSU).

Required Privilege Level

view

Output Fields

Table 48 on page 807 lists the output fields for the show chassis cluster information issu command.
Output fields are listed in the approximate order in which they appear.
807

Table 48: show chassis cluster information issu Output Fields

Field Name Field Description

Node name Node (device) in the chassis cluster (node0 or node1).

CS Prereq Status of all cold synchronization prerequisites:

• if_state sync—Status of if_state synchronization.

• fabric link—Status of fabric link synchronization.

• policy data sync—Status of policy data synchronization.

• cp ready—Status of the central point.

• VPN data sync—Status of the VPN data synchronization.

CS RTO sync Status of cold synchronization runtime objects.

CS postreq Status of cold synchronization postrequirements.

Sample Output

show chassis cluster information issu

user@host> show chassis cluster information issu

node0:
--------------------------------------------------------------------------
Cold Synchronization Progress:
CS Prereq 10 of 10 SPUs completed
1. if_state sync 10 SPUs completed
2. fabric link 10 SPUs completed
3. policy data sync 10 SPUs completed
4. cp ready 10 SPUs completed
5. VPN data sync 10 SPUs completed
CS RTO sync 10 of 10 SPUs completed
808

CS Postreq 10 of 10 SPUs completed

node1:
--------------------------------------------------------------------------
Cold Synchronization Progress:
CS Prereq 10 of 10 SPUs completed
1. if_state sync 10 SPUs completed
2. fabric link 10 SPUs completed
3. policy data sync 10 SPUs completed
4. cp ready 10 SPUs completed
5. VPN data sync 10 SPUs completed
CS RTO sync 10 of 10 SPUs completed
CS Postreq 10 of 10 SPUs completed

Release Information

Command introduced in Junos OS Release 12.1X47-D10.

RELATED DOCUMENTATION

show chassis cluster status | 829

show chassis cluster interfaces

IN THIS SECTION

Syntax | 809

Description | 809

Required Privilege Level | 809

Output Fields | 809

Sample Output | 811


809

Sample Output | 812

Sample Output | 813

Sample Output | 814

Sample Output | 815

Sample Output | 816

Sample Output | 817

Release Information | 817

Syntax

show chassis cluster interfaces

Description

Display the status of the control interface in a chassis cluster configuration.

Required Privilege Level

view

Output Fields

Table 49 on page 810 lists the output fields for the show chassis cluster interfaces command. Output
fields are listed in the approximate order in which they appear.
810

Table 49: show chassis cluster interfaces Output Fields

Field Name Field Description

Control link status State of the chassis cluster control interface: up or down.

Control interfaces • Index—Index number of the chassis cluster control interface.

• Interface—Name of the chassis cluster control interface. The control


interface names differ based on the routing engine. For RE2, the control
interfaces are displayed as em0 and em1 and for RE3, the control
interfaces are displayed as ixlv0 and igb0.

• Monitored-Status—Monitored state of the interface: up or down.

• Internal SA—State of the internal SA option on the chassis cluster control


link: enabled or disabled.

NOTE: This field is available only on SRX5000 line devices.

• Security—State of MACsec on chassis cluster control interfaces.

Fabric link status State of the fabric interface: up or down.

Fabric interfaces • Name—Name of the fabric interface.

• Child-interface—Name of the child fabric interface.

• Status—State of the interface: up or down.

• Security—State of MACsec on chassis cluster fabric interfaces.

Redundant-ethernet Information • Name—Name of the redundant Ethernet interface.

• Status—State of the interface: up or down.

• Redundancy-group—Identification number (1–255) of the redundancy group


associated with the redundant Ethernet interface.
811

Table 49: show chassis cluster interfaces Output Fields (Continued)

Field Name Field Description

Redundant-pseudo-interface • Name—Name of the redundant pseudointerface.


Information
• Status—State of the redundant pseudointerface: up or down.

• Redundancy-group—Identification number (1–255) of the redundancy group


associated with the redundant pseudointerface.

Interface Monitoring • Interface—Name of the interface to be monitored.

• Weight—Relative importance of the interface to redundancy group


operation.

• Status—State of the interface: up or down.

• Redundancy-group—Identification number of the redundancy group


associated with the interface.

Sample Output

show chassis cluster interfaces (SRX5000 line devices with RE3)

user@host> show chassis cluster interfaces


Control link status: Down

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 ixlv0 Down Enabled Disabled
1 igb0 Down Enabled Disabled

Fabric link status: Down

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0
812

fab0

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Down Not configured
reth1 Down Not configured
reth2 Down Not configured
reth3 Down Not configured
reth4 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Sample Output

show chassis cluster interfaces (SRX5000 line devices with RE2)

user@host> show chassis cluster interfaces


Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Up Disabled Disabled
1 em1 Down Disabled Disabled
Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 xe-1/0/3 Up / Down Disabled
fab0
fab1 xe-7/0/3 Up / Down Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
813

reth1 Up 2
reth2 Down Not configured
reth3 Down Not configured
reth4 Down Not configured
reth5 Down Not configured
reth6 Down Not configured
reth7 Down Not configured
reth8 Down Not configured
reth9 Down Not configured
reth10 Down Not configured
reth11 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 1

Interface Monitoring:
Interface Weight Status Redundancy-group
ge-0/1/9 100 Up 0
ge-0/1/9 100 Up

Sample Output

show chassis cluster interfaces

user@host> show chassis cluster interfaces

The following output is specific to fabric monitoring failure:

Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Up Disabled Disabled

Fabric link status: Down


814

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 ge-0/0/2 Down / Down Disabled
fab0
fab1 ge-9/0/2 Up / Up Disabled
fab1

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Sample Output

show chassis cluster interfaces (SRX5400, SRX5600, and SRX5800 Devices with SRX5000
line SRX5K-SCB3 [SCB3] with Enhanced Midplanes and SRX5K-MPC3-100G10G [IOC3] or
SRX5K-MPC3-40G10G [IOC3])

user@host> show chassis cluster interfaces

The following output is specific to SRX5400, SRX5600, and SRX5800 devices in a chassis cluster cluster,
when the PICs containing fabric links on the SRX5K-MPC3-40G10G (IOC3) are powered off to turn on
alternate PICs. If no alternate fabric links are configured on the PICs that are turned on, RTO
synchronous communication between the two nodes stops and the chassis cluster session state will not
back up, because the fabric link is missing.

Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Up Disabled Disabled
1 em1 Down Disabled Disabled

Fabric link status: Down

Fabric interfaces:
Name Child-interface Status Security
815

(Physical/Monitored)
fab0 <<< fab child missing once PIC off lined Disabled
fab0
fab1 xe-10/2/7 Up / Down Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up Not configured
reth1 Down 1

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 0

Sample Output

show chassis cluster interfaces (vSRX Virtual Firewall)

user@host> show chassis cluster interfaces

The following output is specific to view control link status with internal SAs.

Control link status: Up

Control interfaces:
Index Interface Status Internal SA
305
0 em0 Up enabled
306
1 em1 Down enabled
816

Sample Output

show chassis cluster interfaces (SRX1500 Devices)

user@host> show chassis cluster interfaces

Check chassis cluster control link and fabric link status.

Control link status: Up

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Up Disabled Disabled

Fabric link status: Up

Fabric interfaces:
Name Child-interface Status Security
(Physical/Monitored)
fab0 ge-0/0/11 Up / Up Disabled
fab0
fab1 ge-7/0/11 Up / Up Disabled
fab1

Redundant-ethernet Information:
Name Status Redundancy-group
reth0 Up 1
reth1 Up 1
reth2 Down Not configured
reth3 Down Not configured
reth4 Down Not configured

Redundant-pseudo-interface Information:
Name Status Redundancy-group
lo0 Up 1

Interface Monitoring:
Interface Weight Status Redundancy-group
(Physical/Monitored)
ge-0/0/4 255 Up / Up 1
ge-7/0/4 255 Up / Up 1
817

ge-0/0/2 255 Up / Up 1
ge-7/0/2 255 Up / Up 1

command-name

After you disable control link:

Control link status: Admin Down

Control interfaces:
Index Interface Monitored-Status Internal-SA Security
0 em0 Down Disabled Disabled

Sample Output

Release Information

Command modified in Junos OS Release 9.0. Output changed to support dual control ports in Junos OS
Release 10.0. Output changed to support control interfaces in Junos OS Release 11.2. Output changed
to support redundant pseudo interfaces in Junos OS Release 12.1X44-D10. For SRX5000 line devices,
output changed to support the internal security association (SA) option in Junos OS Release 12.1X45-
D10. Output changed to support MACsec status on control and fabric interfaces in Junos OS Release
15.1X49-D60. For vSRX Virtual Firewall, output changed to support the internal security association
(SA) option in Junos OS Release 19.4R1.

RELATED DOCUMENTATION

cluster (Chassis) | 606


818

show chassis cluster ip-monitoring status


redundancy-group

IN THIS SECTION

Syntax | 818

Description | 818

Options | 818

Required Privilege Level | 819

Output Fields | 819

Sample Output | 820

Sample Output | 821

Release Information | 822

Syntax

show chassis cluster ip-monitoring status


<redundancy-group group-number>

Description

Display the status of all monitored IP addresses for a redundancy group.

Options

• none— Display the status of monitored IP addresses for all redundancy groups on the node.

• redundancy-group group-number— Display the status of monitored IP addresses under the specified
redundancy group.
819

Required Privilege Level

view

Output Fields

Table 50 on page 819 lists the output fields for the show chassis cluster ip-monitoring status command.

Table 50: show chassis cluster ip-monitoring status Output Fields

Field Name Field Description

Redundancy-group ID number (0 - 255) of a redundancy group in the cluster.

Global threshold Failover value for all IP addresses monitored by the redundancy group.

Current threshold Value equal to the global threshold minus the total weight of the unreachable
IP address.

IP Address Monitored IP address in the redundancy group.

Status Current reachability state of the monitored IP address.

Values for this field are: reachable, unreachable, and unknown. The status is
“unknown” if Packet Forwarding Engines (PFEs) are not yet up and running.

Failure count Number of attempts to reach an IP address.

Reason Explanation for the reported status. See Table 51 on page 820.

Weight Combined weight (0 - 255) assigned to all monitored IP addresses. A higher


weight value indicates greater importance.

Expanded reason output fields for unreachable IP addresses added in Junos OS Release 10.1. You might
see any of the following reasons displayed.
820

Table 51: show chassis cluster ip-monitoring status redundancy group Reason Fields

Reason Reason Description

No route to host The router could not resolve the ARP, which is needed to send the ICMP
packet to the host with the monitored IP address.

No auxiliary IP found The redundant Ethernet interface does not have an auxiliary IP address
configured.

Reth child not up A child interface of a redundant Ethernet interface is down.

redundancy-group state unknown Unable to obtain the state (primary, secondary, secondary-hold, disable) of a
redundancy-group.

No reth child MAC address Could not extract the MAC address of the redundant Ethernet child interface.

Secondary link not monitored The secondary link might be down (the secondary child interface of a
redundant Ethernet interface is either down or non-functional).

Unknown The IP address has just been configured and the router still does not know the
status of this IP.

or

Do not know the exact reason for the failure.

Sample Output

show chassis cluster ip-monitoring status

user@host> show chassis cluster ip-monitoring status


node0:
--------------------------------------------------------------------------

Redundancy group: 1
Global threshold: 200
821

Current threshold: -120

IP address Status Failure count Reason Weight


10.254.5.44 reachable 0 n/a 220
10.2.2.1 reachable 0 n/a 100

node1:
--------------------------------------------------------------------------

Redundancy group: 1
Global threshold: 200
Current threshold: -120

IP address Status Failure count Reason Weight


10.254.5.44 reachable 0 n/a 220
10.2.2.1 reachable 0 n/a 100

Sample Output

show chassis cluster ip-monitoring status redundancy-group

user@host> show chassis cluster ip-monitoring status redundancy-group 1


node0:
--------------------------------------------------------------------------

Redundancy group: 1

IP address Status Failure count Reason


10.254.5.44 reachable 0 n/a
10.2.2.1 reachable 0 n/a
10.1.1.5 reachable 0 n/a
10.1.1.4 reachable 0 n/a
10.1.1.1 reachable 0 n/a

node1:
--------------------------------------------------------------------------

Redundancy group: 1
822

IP address Status Failure count Reason


10.254.5.44 reachable 0 n/a
10.2.2.1 reachable 0 n/a
10.1.1.5 reachable 0 n/a
10.1.1.4 reachable 0 n/a
10.1.1.1 reachable 0 n/a

Release Information

Command introduced in Junos OS Release 9.6. Support.

RELATED DOCUMENTATION

clear chassis cluster failover-count

show chassis cluster statistics

IN THIS SECTION

Syntax | 823

Description | 823

Required Privilege Level | 823

Output Fields | 823

Sample Output | 826

Sample Output | 827

Sample Output | 828

Release Information | 829


823

Syntax

show chassis cluster statistics

Description

This command displays information about chassis cluster services and interfaces.

Required Privilege Level

view

Output Fields

Table 52 on page 824 lists the output fields for the show chassis cluster statistics command. Output
fields are listed in the approximate order in which they appear.
824

Table 52: show chassis cluster statistics Output Fields

Field Name Field Description

Control link statistics Statistics of the control link used by chassis cluster traffic. Statistics for Control
link 1 are displayed when you use dual control links (SRX5000 lines only).
Note that the output for the SRX5000 lines will always show Control link 0
and Control link 1 statistics, even though only one control link is active or
working.

• Heartbeat packets sent—Number of heartbeat messages sent on the


control link.

• Heartbeat packets received—Number of heartbeat messages received on


the control link.

• Heartbeat packet errors—Number of heartbeat packets received with


errors on the control link.

Fabric link statistics Statistics of the fabric link used by chassis cluster traffic. Statistics for Child
Link 1 are displayed when you use dual fabric links.

• Probes sent—Number of probes sent on the fabric link.

• Probes received—Number of probes received on the fabric link.


825

Table 52: show chassis cluster statistics Output Fields (Continued)

Field Name Field Description

Services Synchronized • Service name—Name of the service.

• Rtos sent—Number of runtime objects (RTOs) sent.

• Rtos received—Number of RTOs received.

• Translation context—Messages synchronizing Network Address Translation


(NAT) translation context.

• Incoming NAT—Messages synchronizing incoming Network Address


Translation (NAT) service.

• Resource manager—Messages synchronizing resource manager groups and


resources.

• Session create—Messages synchronizing session creation.

• Session close—Messages synchronizing session close.

• Session change—Messages synchronizing session change.

• Gate create—Messages synchronizing creation of pinholes (temporary


openings in the firewall).

• Session ageout refresh request—Messages synchronizing request session


after age-out.

• Session ageout refresh reply—Messages synchronizing reply session after


age-out.

• IPsec VPN—Messages synchronizing VPN session.

• Firewall user authentication—Messages synchronizing firewall user


authentication session.

• MGCP ALG—Messages synchronizing MGCP ALG sessions.

• H323 ALG—Messages synchronizing H.323 ALG sessions.

• SIP ALG—Messages synchronizing SIP ALG sessions.

• SCCP ALG—Messages synchronizing SCCP ALG sessions.


826

Table 52: show chassis cluster statistics Output Fields (Continued)

Field Name Field Description

• PPTP ALG—Messages synchronizing PPTP ALG sessions.

• RTSP ALG—Messages synchronizing RTSP ALG sessions.

• MAC address learning—Messages synchronizing MAC address learning.

Sample Output

show chassis cluster statistics

user@host> show chassis cluster statistics


Control link statistics:
Control link 0:
Heartbeat packets sent: 798
Heartbeat packets received: 784
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 793
Probes received: 0
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
Session create 0 0
Session close 0 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPsec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
827

SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RTSP ALG 0 0
MAC address learning 0 0

Sample Output

show chassis cluster statistics (SRX5000 Line Devices)

user@host> show chassis cluster statistics


Control link statistics:
Control link 0:
Heartbeat packets sent: 258689
Heartbeat packets received: 258684
Heartbeat packets errors: 0
Control link 1:
Heartbeat packets sent: 258689
Heartbeat packets received: 258684
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 258681
Probes received: 258681
Child link 1
Probes sent: 258501
Probes received: 258501
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
Session create 1 0
Session close 1 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
828

Firewall user authentication 0 0


MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Sample Output

show chassis cluster statistics (SRX5000 Line Devices)

user@host> show chassis cluster statistics


Control link statistics:
Control link 0:
Heartbeat packets sent: 82371
Heartbeat packets received: 82321
Heartbeat packets errors: 0
Control link 1:
Heartbeat packets sent: 0
Heartbeat packets received: 0
Heartbeat packets errors: 0
Fabric link statistics:
Child link 0
Probes sent: 258681
Probes received: 258681
Child link 1
Probes sent: 258501
Probes received: 258501
Services Synchronized:
Service name RTOs sent RTOs received
Translation context 0 0
Incoming NAT 0 0
Resource manager 0 0
Session create 1 0
829

Session close 1 0
Session change 0 0
Gate create 0 0
Session ageout refresh requests 0 0
Session ageout refresh replies 0 0
IPSec VPN 0 0
Firewall user authentication 0 0
MGCP ALG 0 0
H323 ALG 0 0
SIP ALG 0 0
SCCP ALG 0 0
PPTP ALG 0 0
RPC ALG 0 0
RTSP ALG 0 0
RAS ALG 0 0
MAC address learning 0 0
GPRS GTP 0 0

Release Information

Command modified in Junos OS Release 9.0.

Output changed to support dual control ports in Junos OS Release 10.0.

RELATED DOCUMENTATION

clear chassis cluster statistics | 741

show chassis cluster status

IN THIS SECTION

Syntax | 830

Description | 830
830

Options | 830

Required Privilege Level | 830

Output Fields | 831

Sample Output | 832

Sample Output | 833

Sample Output | 833

Release Information | 834

Syntax

show chassis cluster status


<redundancy-group group-number >

Description

Display the current status of the Chassis Cluster. You can use this command to check the status of
chassis cluster nodes, redundancy groups, and failover status.

Options

• none—Display the status of all redundancy groups in the chassis cluster.

• redundancy-group group-number—(Optional) Display the status of the specified redundancy group.

Required Privilege Level

view
831

Output Fields

Table 53 on page 831 lists the output fields for the show chassis cluster status command. Output fields
are listed in the approximate order in which they appear.

Table 53: show chassis cluster status Output Fields

Field Name Field Description

Cluster ID ID number (1-15) of a cluster is applicable for releases upto Junos OS Release
12.1X45-D10. ID number (1-255) is applicable for Releases 12.1X45-D10 and
later. Setting a cluster ID to 0 is equivalent to disabling a cluster.

Redundancy-Group You can create up to 128 redundancy groups in the chassis cluster.

Node name Node (device) in the chassis cluster (node0 or node1).

Priority Assigned priority for the redundancy group on that node.

Status State of the redundancy group (Primary, Secondary, Lost, or Unavailable).

• Primary—Redundancy group is active and passing traffic.

• Secondary—Redundancy group is passive and not passing traffic.

• Lost—Node loses contact with the other node through the control link.
Most likely to occur when both nodes are in a cluster and there is a control
link failure, one node cannot exchange heartbeats, or when the other node
is rebooted.

• Unavailable—Node has not received a single heartbeat over the control link
from the other node since the other node booted up. Most likely to occur
when one node boots up before the other node, or if only one node is
present in the cluster.

Preempt • Yes: Primary state can be preempted based on priority.

• No: Change in priority will not preempt the primary state.


832

Table 53: show chassis cluster status Output Fields (Continued)

Field Name Field Description

Manual failover • Yes: Primary state is set manually through the CLI with the request chassis
cluster failover node or request chassis cluster failover redundancy-group
command. This overrides Priority and Preempt.

• No: Primary state is not set manually through the CLI.

Monitor-failures • None: Cluster working properly.

• Monitor Failure code: Cluster is not working properly and the respective
failure code is displayed.

Sample Output

show chassis cluster status

user@host> show chassis cluster status

Monitor Failure codes:


CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures

Redundancy group: 0 , Failover count: 1


node0 200 primary no no None
node1 1 secondary no no None

Redundancy group: 1 , Failover count: 1


833

node0 101 primary no no None


node1 1 secondary no no None

Sample Output

show chassis cluster status with preemptive delay

user@host> show chassis cluster status

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures
Redundancy group: 0, Failover count: 1
node0 200 primary no no None
node1 100 secondary no no None
Redundancy group: 1, Failover count: 3
node0 200 primary-preempt-hold yes no None node1 100
secondary yes no None

Sample Output

show chassis cluster status redundancy-group 1

user@host> show chassis cluster status redundancy-group 1

Monitor Failure codes:


CS Cold Sync monitoring FL Fabric Connection monitoring
GR GRES monitoring HW Hardware monitoring
IF Interface monitoring IP IP monitoring
LB Loopback monitoring MB Mbuf monitoring
NH Nexthop monitoring NP NPC monitoring
SP SPU monitoring SM Schedule monitoring
CF Config Sync monitoring

Cluster ID: 1
Node Priority Status Preempt Manual Monitor-failures
834

Redundancy group: 1 , Failover count: 1


node0 101 primary no no None
node1 1 secondary no no None

Release Information

Support for monitoring failures added in Junos OS Release 12.1X47-D10.

RELATED DOCUMENTATION

redundancy-group (Chassis Cluster)


clear chassis cluster failover-count
request chassis cluster failover node
request chassis cluster failover reset

show chassis environment (Security)

IN THIS SECTION

Syntax | 835

Description | 835

Options | 835

Required Privilege Level | 835

Output Fields | 836

Sample Output | 836

Release Information | 842


835

Syntax

show chassis environment

Description

Display environmental information about the services gateway chassis, including the temperature and
information about the fans, power supplies, and Routing Engine.

Options

none Display environmental information about the device.

cb slot-number Display chassis environmental information for the Control Board.

fpc fpc-slot Display chassis environmental information for a specified Flexible PIC
Concentrator.

fpm Display chassis environmental information for the craft interface (FPM).

node Display node specific chassis information.

pem slot-number Display chassis environmental information for the specified Power Entry
Module.

routing-engine slot- Display chassis environmental information for the specified Routing Engine.
number

Required Privilege Level

view
836

Output Fields

Table 54 on page 836 lists the output fields for the show chassis environment command. Output fields are
listed in the approximate order in which they appear.

Table 54: show chassis environment Output Fields

Field Name Field Description

Temp Temperature of air flowing through the chassis in degrees Celsius (C) and Fahrenheit (F).

Fan Fan status: OK, Testing (during initial power-on), Failed, or Absent.

Sample Output

show chassis environment

user@host> show chassis environment


user@host> show chassis environment
Class Item Status Measurement
Temp PEM 0 OK 40 degrees C / 104 degrees F
PEM 1 OK 40 degrees C / 104 degrees F
PEM 2 OK 40 degrees C / 104 degrees F
PEM 3 OK 45 degrees C / 113 degrees F
Routing Engine 0 OK 31 degrees C / 87 degrees F
Routing Engine 0 CPU OK 27 degrees C / 80 degrees F
Routing Engine 1 Absent
Routing Engine 1 CPU Absent
CB 0 Intake OK 28 degrees C / 82 degrees F
CB 0 Exhaust A OK 27 degrees C / 80 degrees F
CB 0 Exhaust B OK 29 degrees C / 84 degrees F
CB 0 ACBC OK 29 degrees C / 84 degrees F
CB 0 SF A OK 36 degrees C / 96 degrees F
CB 0 SF B OK 31 degrees C / 87 degrees F
CB 1 Intake OK 27 degrees C / 80 degrees F
CB 1 Exhaust A OK 26 degrees C / 78 degrees F
CB 1 Exhaust B OK 29 degrees C / 84 degrees F
837

CB 1 ACBC OK 27 degrees C / 80 degrees F


CB 1 SF A OK 36 degrees C / 96 degrees F
CB 1 SF B OK 31 degrees C / 87 degrees F
CB 2 Intake Absent
CB 2 Exhaust A Absent
CB 2 Exhaust B Absent
CB 2 ACBC Absent
CB 2 XF A Absent
CB 2 XF B Absent
FPC 0 Intake OK 47 degrees C / 116 degrees F
FPC 0 Exhaust A OK 44 degrees C / 111 degrees F
FPC 0 Exhaust B OK 52 degrees C / 125 degrees F
FPC 0 xlp0 TSen OK 51 degrees C / 123 degrees F
FPC 0 xlp0 Chip OK 46 degrees C / 114 degrees F
FPC 0 xlp1 TSen OK 51 degrees C / 123 degrees F
FPC 0 xlp1 Chip OK 47 degrees C / 116 degrees F
FPC 0 xlp2 TSen OK 44 degrees C / 111 degrees F
FPC 0 xlp2 Chip OK 42 degrees C / 107 degrees F
FPC 0 xlp3 TSen OK 48 degrees C / 118 degrees F
FPC 0 xlp3 Chip OK 43 degrees C / 109 degrees F
FPC 1 Intake OK 41 degrees C / 105 degrees F
FPC 1 Exhaust A OK 41 degrees C / 105 degrees F
FPC 1 Exhaust B OK 51 degrees C / 123 degrees F
FPC 1 LU TSen OK 46 degrees C / 114 degrees F
FPC 1 LU Chip OK 45 degrees C / 113 degrees F
FPC 1 XM TSen OK 46 degrees C / 114 degrees F
FPC 1 XM Chip OK 52 degrees C / 125 degrees F
FPC 1 xlp0 TSen OK 49 degrees C / 120 degrees F
FPC 1 xlp0 Chip OK 42 degrees C / 107 degrees F
FPC 1 xlp1 TSen OK 49 degrees C / 120 degrees F
FPC 1 xlp1 Chip OK 44 degrees C / 111 degrees F
FPC 1 xlp2 TSen OK 38 degrees C / 100 degrees F
FPC 1 xlp2 Chip OK 39 degrees C / 102 degrees F
FPC 1 xlp3 TSen OK 44 degrees C / 111 degrees F
FPC 1 xlp3 Chip OK 42 degrees C / 107 degrees F
FPC 2 Intake OK 29 degrees C / 84 degrees F
FPC 2 Exhaust A OK 34 degrees C / 93 degrees F
FPC 2 Exhaust B OK 40 degrees C / 104 degrees F
FPC 2 I3 0 TSensor OK 42 degrees C / 107 degrees F
FPC 2 I3 0 Chip OK 41 degrees C / 105 degrees F
FPC 2 I3 1 TSensor OK 40 degrees C / 104 degrees F
FPC 2 I3 1 Chip OK 39 degrees C / 102 degrees F
FPC 2 I3 2 TSensor OK 38 degrees C / 100 degrees F
838

FPC 2 I3 2 Chip OK 37 degrees C / 98 degrees F


FPC 2 I3 3 TSensor OK 35 degrees C / 95 degrees F
FPC 2 I3 3 Chip OK 35 degrees C / 95 degrees F
FPC 2 IA 0 TSensor OK 45 degrees C / 113 degrees F
FPC 2 IA 0 Chip OK 42 degrees C / 107 degrees F
FPC 2 IA 1 TSensor OK 41 degrees C / 105 degrees F
FPC 2 IA 1 Chip OK 43 degrees C / 109 degrees F
FPC 9 Intake OK 29 degrees C / 84 degrees F
FPC 9 Exhaust A OK 41 degrees C / 105 degrees F
FPC 9 Exhaust B OK 48 degrees C / 118 degrees F
FPC 9 LU TSen OK 48 degrees C / 118 degrees F
FPC 9 LU Chip OK 47 degrees C / 116 degrees F
FPC 9 XM TSen OK 48 degrees C / 118 degrees F
FPC 9 XM Chip OK 54 degrees C / 129 degrees F
FPC 9 xlp0 TSen OK 45 degrees C / 113 degrees F
FPC 9 xlp0 Chip OK 42 degrees C / 107 degrees F
FPC 9 xlp1 TSen OK 49 degrees C / 120 degrees F
FPC 9 xlp1 Chip OK 46 degrees C / 114 degrees F
FPC 9 xlp2 TSen OK 37 degrees C / 98 degrees F
FPC 9 xlp2 Chip OK 40 degrees C / 104 degrees F
FPC 9 xlp3 TSen OK 45 degrees C / 113 degrees F
FPC 9 xlp3 Chip OK 41 degrees C / 105 degrees F
FPC 10 Intake OK 32 degrees C / 89 degrees F
FPC 10 Exhaust A OK 44 degrees C / 111 degrees F
FPC 10 Exhaust B OK 53 degrees C / 127 degrees F
FPC 10 LU 0 TSen OK 43 degrees C / 109 degrees F
FPC 10 LU 0 Chip OK 52 degrees C / 125 degrees F
FPC 10 LU 1 TSen OK 43 degrees C / 109 degrees F
FPC 10 LU 1 Chip OK 44 degrees C / 111 degrees F
FPC 10 LU 2 TSen OK 43 degrees C / 109 degrees F
FPC 10 LU 2 Chip OK 50 degrees C / 122 degrees F
FPC 10 LU 3 TSen OK 43 degrees C / 109 degrees F
FPC 10 LU 3 Chip OK 58 degrees C / 136 degrees F
FPC 10 XM 0 TSen OK 43 degrees C / 109 degrees F
FPC 10 XM 0 Chip OK 53 degrees C / 127 degrees F
FPC 10 XF 0 TSen OK 43 degrees C / 109 degrees F
FPC 10 XF 0 Chip OK 64 degrees C / 147 degrees F
FPC 10 PLX Switch TSen OK 43 degrees C / 109 degrees F
FPC 10 PLX Switch Chip OK 44 degrees C / 111 degrees F
FPC 11 Intake OK 32 degrees C / 89 degrees F
FPC 11 Exhaust A OK 41 degrees C / 105 degrees F
FPC 11 Exhaust B OK 56 degrees C / 132 degrees F
FPC 11 LU 0 TSen OK 45 degrees C / 113 degrees F
839

FPC 11 LU 0 Chip OK 50 degrees C / 122 degrees F


FPC 11 LU 1 TSen OK 45 degrees C / 113 degrees F
FPC 11 LU 1 Chip OK 47 degrees C / 116 degrees F
FPC 11 LU 2 TSen OK 45 degrees C / 113 degrees F
FPC 11 LU 2 Chip OK 52 degrees C / 125 degrees F
FPC 11 LU 3 TSen OK 45 degrees C / 113 degrees F
FPC 11 LU 3 Chip OK 60 degrees C / 140 degrees F
FPC 11 XM 0 TSen OK 45 degrees C / 113 degrees F
FPC 11 XM 0 Chip OK 56 degrees C / 132 degrees F
FPC 11 XF 0 TSen OK 45 degrees C / 113 degrees F
FPC 11 XF 0 Chip OK 65 degrees C / 149 degrees F
FPC 11 PLX Switch TSen OK 45 degrees C / 113 degrees F
FPC 11 PLX Switch Chip OK 46 degrees C / 114 degrees F
Fans Top Fan Tray Temp OK 34 degrees C / 93 degrees F
Top Tray Fan 1 OK Spinning at normal speed
Top Tray Fan 2 OK Spinning at normal speed
Top Tray Fan 3 OK Spinning at normal speed
Top Tray Fan 4 OK Spinning at normal speed
Top Tray Fan 5 OK Spinning at normal speed
Top Tray Fan 6 OK Spinning at normal speed
Top Tray Fan 7 OK Spinning at normal speed
Top Tray Fan 8 OK Spinning at normal speed
Top Tray Fan 9 OK Spinning at normal speed
Top Tray Fan 10 OK Spinning at normal speed
Top Tray Fan 11 OK Spinning at normal speed
Top Tray Fan 12 OK Spinning at normal speed
Bottom Fan Tray Temp OK 31 degrees C / 87 degrees F
Bottom Tray Fan 1 OK Spinning at normal speed
Bottom Tray Fan 2 OK Spinning at normal speed
Bottom Tray Fan 3 OK Spinning at normal speed
Bottom Tray Fan 4 OK Spinning at normal speed
Bottom Tray Fan 5 OK Spinning at normal speed
Bottom Tray Fan 6 OK Spinning at normal speed
Bottom Tray Fan 7 OK Spinning at normal speed
Bottom Tray Fan 8 OK Spinning at normal speed
Bottom Tray Fan 9 OK Spinning at normal speed
Bottom Tray Fan 10 OK Spinning at normal speed
Bottom Tray Fan 11 OK Spinning at normal speed
Bottom Tray Fan 12 OK Spinning at normal speed OK
840

When you enter the show chassis environment pem command, the sample output is shown for AC
PEM.

user@host# run show chassis environment pem node 0 | no-more


node0:
--------------------------------------------------------------------------
PEM 0 status:
State Online
Airflow Front to Back
Temperature OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
12 9 108 16
PEM 1 status:
State Online
Airflow Front to Back
Temperature OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
12 9 108 16

When you enter the show chassis environment pem command, the sample output is shown for DC
PEM.

user@host> show chassis environment pem


node0:
--------------------------------------------------------------------------
PEM 0 status:
State Online
Temperature OK
DC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
50 12 600 24
PEM 1 status:
State Online
Temperature OK
DC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
50 31 1550 63

node1:
--------------------------------------------------------------------------
PEM 0 status:
841

State Online
Temperature OK
DC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
50 12 600 24
PEM 1 status:
State Online
Temperature OK
DC Input: OK
DC Output Voltage(V) Current(A) Power(W) Load(%)
49 31 1519 62

show chassis environment fpc (SRX5800, SRX5400, and SRX5600)

user@host> show chassis environment fpc


FPC 1 status:
State Online
Temperature Intake 34 degrees C / 93 degrees F
Temperature Exhaust A 48 degrees C / 118 degrees F
Temperature Exhaust B 48 degrees C / 118 degrees F
Temperature CPU0 DTS 55 degrees C / 131 degrees F
Temperature CPU1 DTS 60 degrees C / 140 degrees F
Temperature CPU2 DTS 54 degrees C / 129 degrees F
Temperature CPU3 DTS 70 degrees C / 158 degrees F
Temperature Talus 0 106 degrees C / 222 degrees F
Temperature Middle 0 40 degrees C / 104 degrees F
Temperature Talus 1 76 degrees C / 168 degrees F
Temperature Middle 1 67 degrees C / 152 degrees F
Power
TALUS0-1.20V 1199 mV 14187 mA 17010 mW
TALUS0-0.90V 900 mV 5000 mA 4500 mW
BIAS0-3.30V 3299 mV 3769 mA 12433 mW
PIC0_CPU_memory_CD-1.20 1199 mV 3781 mA 4533 mW
USB0-5.00V 5000 mV 155 mA 775 mW
PIC0_CPU_memory_AB-1.20 1200 mV 5820 mA 6984 mW
PCH0-1.05V 1050 mV 3582 mA 3761 mW
TALUS1-1.20V 1199 mV 13640 mA 16354 mW
TALUS1-0.90V 899 mV 4679 mA 4206 mW
BIAS1-3.30V 3300 mV 3175 mA 10477 mW
PIC1_CPU_memory_GH-1.20 1200 mV 4648 mA 5577 mW
842

USB1-5.00V 4999 mV 346 mA 1729 mW


PIC1_CPU_memory_EF-1.20 1200 mV 5218 mA 6261 mW
PCH1-1.05V 1050 mV 3328 mA 3494 mW
TPS53641-CPU0 1750 mV 46062 mA 80608 mW
TPS53641-CPU1 1739 mV 47437 mA 82492 mW
TPS53641-CPU2 1750 mV 45250 mA 79187 mW
TPS53641-CPU3 1739 mV 46875 mA 81515 mW
ETH-1.00V 994 mV 2674 mA 2657 mW
TALUS0_Core-0.85V 849 mV 37750 mA 32049 mW
TALUS1_Core-0.85V 849 mV 26750 mA 22710 mW
Power_Brick1-12.00V 12001 mV 21000 mA 252021 mW
Power_Brick2-12.00V 11998 mV 23125 mA 277453 mW
PIM4820_48V0-48.00V 58392 mV 10286 mA 600620 mW
I2C Slave Revision 0

Release Information

Command introduced in Junos OS Release 9.2.

RELATED DOCUMENTATION

show chassis hardware (View) | 868

show chassis environment cb

IN THIS SECTION

Syntax | 843

Description | 843

Options | 843

Required Privilege Level | 843

Output Fields | 843


843

Sample Output | 845

Release Information | 846

Syntax

show chassis environment cb


<slot>

Description

Display environmental information about the Control Boards (CBs) installed on SRX Series Firewalls.

Options

slot (Optional) Display environmental information about the specified CB.

Required Privilege Level

view

Output Fields

Table 55 on page 844 lists the output fields for the show chassis environment cb command. Output
fields are listed in the approximate order in which they appear.
844

Table 55: show chassis environment cb Output Fields

Field Name Field Description

State Status of the CB. If two CBs are installed and online, one is functioning as the primary, and
the other is the standby.

• Online—CB is online and running.

• Offline— CB is powered down.

Temperature Temperature in Celsius (C) and Fahrenheit (F) of the air flowing past the CB.

• Temperature Intake—Measures the temperature of the air intake to cool the power
supplies.

• Temperature Exhaust—Measures the temperature of the hot air exhaust.

Power Power required and measured on the CB. The left column displays the required power, in
volts. The right column displays the measured power, in millivolts.

BUS Revision Revision level of the generic bus device.

FPGA Revision Revision level of the field-programmable gate array (FPGA).

PMBus device Enhanced SCB on SRX Series Firewalls allows the system to save power by supplying only
the amount of voltage that is required. Configurable PMBus devices are used to provide the
voltage for each individual device. There is one PMBus device for each XF ASIC so that the
output can be customized to each device. The following PMBus device information is
displayed for devices with Enhanced MX SCB:

• Expected voltage

• Measured voltage

• Measured current

• Calculated power
845

Sample Output

show chassis environment cb (SRX5600 devices with SRX5K-SCB3 [SCB3] and Enhanced
Midplanes)

user@host> show chassis environment cb node 0


node0:
--------------------------------------------------------------------------
--------------------------------------------------------------------------
CB 0 status:
State Online Master
Temperature 34 degrees C / 93 degrees F
Power 1
1.0 V 1002
1.2 V 1198
1.5 V 1501
1.8 V 1801
2.5 V 2507
3.3 V 3300
5.0 V 5014
5.0 V RE 4982
12.0 V 11988
12.0 V RE 11930
Power 2
4.6 V bias MidPlane 4801
11.3 V bias PEM 11292
11.3 V bias FPD 11272
11.3 V bias POE 0 11214
11.3 V bias POE 1 11253
Bus Revision 96
FPGA Revision 16
PMBus Expected Measured Measured Calculated
device voltage voltage current power
XF ASIC A 1033 mV 1033 mV 15500 mA 16011 mW
XF ASIC B 1034 mV 1033 mV 15000 mA 15495 mW
846

show chassis environment cb node 1 (SRX5600 devices with SRX5K-SCB3 [SCB3] and
Enhanced Midplanes)

user@host> show chassis environment cb node 1


node1:
--------------------------------------------------------------------------
CB 0 status:
State Online Master
Temperature 35 degrees C / 95 degrees F
Power 1
1.0 V 1002
1.2 V 1198
1.5 V 1504
1.8 V 1801
2.5 V 2507
3.3 V 3325
5.0 V 5014
5.0 V RE 4943
12.0 V 12007
12.0 V RE 12007
Power 2
4.6 V bias MidPlane 4814
11.3 V bias PEM 11272
11.3 V bias FPD 11330
11.3 V bias POE 0 11176
11.3 V bias POE 1 11292
Bus Revision 96
FPGA Revision 16
PMBus Expected Measured Measured Calculated
device voltage voltage current power
XF ASIC A 958 mV 959 mV 13500 mA 12946 mW
XF ASIC B 1033 mV 1031 mV 16500 mA 17011 mW

Release Information

Command introduced in Junos OS Release 9.2.

Starting with Junos OS Release 12.1X47-D15, the SRX5K-SCBE (SCB2) is introduced and starting with
Junos OS Release 15.1X49-D10, the SRX5K-SCB3 (SCB3) with enhanced midplane is introduced.
847

RELATED DOCUMENTATION

request chassis cb | 742

show chassis ethernet-switch

IN THIS SECTION

Syntax | 847

Description | 847

Required Privilege Level | 847

Output Fields | 848

Sample Output | 848

Release Information | 854

Syntax

show chassis ethernet-switch


<errors>
<statistics>

Description

Display information about the ports on the Control Board (CB) Ethernet switch and accumulated
Ethernet switch errors on an SRX Series Firewall.

Required Privilege Level

view
848

Output Fields

Table 56 on page 848 lists the output fields for the show chassis ethernet-switch command. Output
fields are listed in the approximate order in which they appear.

Table 56: show chassis ethernet-switch Output Fields

Field Name Field Description

Link is good on port Information about the link between each port on the CB's Ethernet switch and one of the
n connected to following devices:
device
• FPC0 (Flexible PIC Concentrator 0) through FPC7
or
• Local controller
Link is good on Fast
Ethernet port n • Routing Engine
connected to device
• Other Routing Engine (on a system with two Routing Engines)

• SPMB (Switch Processor Mezzanine Board)

Speed is Speed at which the Ethernet link is running.

Duplex is Duplex type of the Ethernet link: full or half.

Autonegotiate is By default, built-in Fast Ethernet ports on a PIC autonegotiate whether to operate at 10
Enabled (or Mbps or 100 Mbps. All other interfaces automatically choose the correct speed based on
Disabled) the PIC type and whether the PIC is configured to operate in multiplexed mode.

Sample Output

show chassis ethernet-switch

user@host> show chassis ethernet-switch


node0:
--------------------------------------------------------------------------
Displaying summary for switch 0
849

Link is good on GE port 0 connected to device: FPC0


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 1 connected to device: FPC1


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 2 connected to device: FPC2


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 3 connected to device: FPC3


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 4 connected to device: FPC4


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is down on GE port 5 connected to device: FPC5

Link is down on GE port 6 connected to device: FPC6

Link is good on GE port 7 connected to device: FPC7


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
850

Flow Control TX is Disabled


Flow Control RX is Disabled

Link is good on GE port 8 connected to device: FPC8


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 9 connected to device: FPC9


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is down on GE port 10 connected to device: FPC10

Link is down on GE port 11 connected to device: FPC11

Link is good on GE port 12 connected to device: Other RE


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 13 connected to device: RE-GigE


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is down on GE port 14 connected to device: Debug-GigE

node1:
--------------------------------------------------------------------------
Displaying summary for switch 0
Link is good on GE port 0 connected to device: FPC0
Speed is 1000Mb
Duplex is full
851

Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 1 connected to device: FPC1


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 2 connected to device: FPC2


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 3 connected to device: FPC3


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 4 connected to device: FPC4


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is down on GE port 5 connected to device: FPC5

Link is down on GE port 6 connected to device: FPC6

Link is good on GE port 7 connected to device: FPC7


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled
852

Link is good on GE port 8 connected to device: FPC8


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 9 connected to device: FPC9


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is down on GE port 10 connected to device: FPC10

Link is down on GE port 11 connected to device: FPC11

Link is good on GE port 12 connected to device: Other RE


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is good on GE port 13 connected to device: RE-GigE


Speed is 1000Mb
Duplex is full
Autonegotiate is Enabled
Flow Control TX is Disabled
Flow Control RX is Disabled

Link is down on GE port 14 connected to device: Debug-GigE

show chassis ethernet-switch errors (SRX5600)

user@host> show chassis ethernet-switch errors


Displaying error for switch 0
Error count not available for port 0 connected to device FPC0
Error count not available for port 1 connected to device FPC1
853

Error count not available for port 2 connected to device FPC2


Error count not available for port 3 connected to device FPC3
Error count not available for port 4 connected to device FPC4
Error count not available for port 5 connected to device FPC5
Error count not available for port 6 connected to device FPC6
Error count not available for port 7 connected to device FPC7
Error count not available for port 8 connected to device FPC8
Error count not available for port 9 connected to device FPC9
Error count not available for port 10 connected to device FPC10
Error count not available for port 11 connected to device FPC11

Error count not available for port 12 connected to device Other RE


Accumulated error counts for port 13 connected to device RE-GigE:
MLT3 0
Lock 0
Xmit 0
ESD 0
False carrier 0
Disconnects 0
FX mode 0
Accumulated error counts for port 14 connected to device Debug-GigE:
MLT3 0
Lock 0
Xmit 0
ESD 0
False carrier 0
Disconnects 0
FX mode 0
Error count not available for port 15 connected to device Nothing
Error count not available for port 16 connected to device Nothing
Error count not available for port 17 connected to device Debug-GigE
Error count not available for port 18 connected to device Nothing
Error count not available for port 19 connected to device Nothing
Error count not available for port 20 connected to device Nothing
Error count not available for port 21 connected to device Nothing
Error count not available for port 22 connected to device Nothing
Error count not available for port 23 connected to device Nothing
Error count not available for port 24 connected to device External-Ethernet
Error count not available for port 25 connected to device External-Ethernet
Error count not available for port 26 connected to device External-Ethernet
Error count not available for port 27 connected to device External-Ethernet
854

Release Information

Command introduced in Junos OS Release 9.2.

show chassis fabric plane

IN THIS SECTION

Syntax | 854

Description | 854

Required Privilege Level | 854

Output Fields | 855

Sample Output | 857

Release Information | 862

Syntax

show chassis fabric plane

Description

Show state of fabric management plane.

Required Privilege Level

view
855

Output Fields

Table 57 on page 855 lists the output fields for the show chassis fabric plane command. Output fields
are listed in the approximate order in which they appear.

Table 57: show chassis fabric plane Output Fields

Field Name Field Description Level of output

Plane Number of the plane. none

Plane state State of each plane: none

• ACTIVE—SIB is operational and running.

• FAULTY— SIB is in alarmed state where the SIB’s plane is


not operational for the following reasons:

• On-board fabric ASIC is not operational.

• Fiber-optic connector faults.

• FPC connector faults.

• SIB midplane connector faults.

FPC Slot number of each Flexible PIC Concentrator (FPC). none

PFE Slot number of each Packet Forwarding Engine and the state none
of the links to the FPC:

• Links ok: Link between SIB and FPC is active.

• Link error: Link between SIB and FPC is not operational.

• Unused: No FPC is present.


856

Table 57: show chassis fabric plane Output Fields (Continued)

Field Name Field Description Level of output

State State of the fabric plane: none

• Online: Fabric plane is operational and running and links


on the SIB are operational.

• Offline: Fabric plane state is Offline because the plane


does not have four or more F2S and one F13 online.

• Empty: Fabric plane state is Empty if all SIBs in the plane


are absent.

• Spare: Fabric plane is redundant and can be operational if


the operational fabric plane encounters an error.

• Check: Fabric plane is in alarmed state due to the


following reason and the cause of the error must be
resolved:

• One or more SIBs (belonging to the fabric plane) in


the Online or Spare states has transitioned to the
Check state.

Check state of the SIB can be caused by link errors or


destination errors.

• Fault: Fabric plane is in alarmed state if one or more SIBs


belonging to the plane are in the Fault state. A SIB can be
in the Fault state because of the following reasons:

• On-board fabric ASIC is not operational.

• Fiber-optic connector faults.

• FPC connector faults.

• SIB midplane connector faults.

• Link errors have exceeded the threshold.


857

Sample Output

show chassis fabric plane (SRX5600 and SRX5800 Devices with SRX5000 Line SCB II
[SRX5K-SCBE] and SRX5K-RE-1800X4)

user@host> show chassis fabric plane


node0:
--------------------------------------------------------------------------
Fabric management PLANE state
Plane 0
Plane state: ACTIVE
FPC 0
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 9
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 1
Plane state: ACTIVE
FPC 0
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
858

FPC 9
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 2
Plane state: ACTIVE
FPC 0
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 9
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 3
Plane state: ACTIVE
FPC 0
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 9
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 4
Plane state: SPARE
FPC 0
859

PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 9
PFE 0 :Links ok
FPC 10
PFE
0 :Links ok
Plane 5
Plane state: SPARE
FPC 0
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 9
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok

node1:
--------------------------------------------------------------------------
Fabric management PLANE state
Plane 0
Plane state: ACTIVE
FPC 0
PFE 0 :Links ok
FPC 1
PFE 0 :Links ok
860

FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 1
Plane state: ACTIVE
FPC 0
PFE 0 :Links ok
FPC 1
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 2
Plane state: ACTIVE
FPC 0
PFE 0 :Links ok
FPC 1
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
861

PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 3
Plane state: ACTIVE
FPC 0
PFE 0 :Links ok
FPC 1
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 4
Plane state: SPARE
FPC 0
PFE 0 :Links ok
FPC 1
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok
Plane 5
Plane state: SPARE
862

FPC 0
PFE 0 :Links ok
FPC 1
PFE 0 :Links ok
FPC 2
PFE 0 :Links ok
FPC 3
PFE 0 :Links ok
FPC 4
PFE 0 :Links ok
FPC 7
PFE 0 :Links ok
FPC 8
PFE 0 :Links ok
FPC 10
PFE 0 :Links ok

Release Information

Command introduced in Junos OS Release 9.2.

RELATED DOCUMENTATION

show chassis fabric plane-location | 862

show chassis fabric plane-location

IN THIS SECTION

Syntax | 863

Description | 863

Required Privilege Level | 863

Output Fields | 863


863

Sample Output | 864

Release Information | 864

Syntax

show chassis fabric plane-location

Description

Show fabric plane location.

Required Privilege Level

view

Output Fields

Table 58 on page 863 lists the output fields for the show chassis fabric plane-location command.
Output fields are listed in the approximate order in which they appear.

Table 58: show chassis fabric plane-location Output Fields

Field Name Field Description

Plane n Plane number.

Control Board n Control Board number.


864

Sample Output

show chassis fabric plane-location (SRX5600 and SRX5800 Devices with SRX5000 Line SCB
II [SRX5K-SCBE] and SRX5K-RE-1800X4)

user@host> show chassis fabric plane-location


node0:
--------------------------------------------------------------------------
------------Fabric Plane Locations-------------
Plane 0 Control Board 0
Plane 1 Control Board 0
Plane 2 Control Board 1
Plane 3 Control Board 1
Plane 4 Control Board 2
Plane 5 Control Board 2

node1:
--------------------------------------------------------------------------
------------Fabric Plane Locations-------------
Plane 0 Control Board 0
Plane 1 Control Board 0
Plane 2 Control Board 1
Plane 3 Control Board 1
Plane 4 Control Board 2
Plane 5 Control Board 2

Release Information

Command introduced in Junos OS Release 9.2.

RELATED DOCUMENTATION

show chassis fabric plane | 854


865

show chassis fabric summary

IN THIS SECTION

Syntax | 865

Description | 865

Options | 865

Required Privilege Level | 865

Output Fields | 866

Sample Output | 867

Release Information | 868

Syntax

show chassis fabric summary

Description

Show summary fabric management state.

Options

This command has no options.

Required Privilege Level

view
866

Output Fields

Table 59 on page 866 lists the output fields for the show chassis fabric summary command. Output
fields are listed in the approximate order in which they appear.

Table 59: show chassis fabric summary Output Fields

Field Name Field Description

Plane Plane number.

State State of the SIB or FPC:

• Online—Switch Interface Board (SIB) is operational and running.

• Empty—SIB is powered down.

• Check—SIB is in the Check state because of the following reasons:

• SIB is not inserted properly.

• Some destination errors are detected on the SIB. In this case, the
Packet Forwarding Engine stops using the SIB to send traffic to the
affected destination Packet Forwarding Engine.

• Some link errors are detected on the channel between the SIB and a
Packet Forwarding Engine. Link errors can be detected at initialization
time or runtime:

• Link errors caused by a link training failure at initialization time—


The Packet Forwarding Engine does not use the SIB to send traffic.
The show chassis fabric fpcs command shows Plane disabled as
status for this link.

• Link errors caused by CRC errors detected at runtime—The Packet


Forwarding Engine continues to use the SIB to send traffic. The
show chassis fabric fpcs command shows Link error as the status
for this link.

For information about link and destination errors, issue the show chassis
fabric fpc commands.

• Spare—SIB is redundant and will move to active state if one of the working
SIBs fails.
867

Table 59: show chassis fabric summary Output Fields (Continued)

Field Name Field Description

Errors Indicates whether there is any error on the SIB.

• None—No errors

• Link Errors—Fabric link errors were found on the SIB RX link.

• Cell drops—Fabric cell drops were found on the SIB ASIC.

• Link, Cell drops—Both link errors and cell drops were detected on at least
one of the FPC’s fabric links.

NOTE: The Errors column is empty only when the FPC or SIB is offline.

Uptime Elapsed time the plane has been online.

Sample Output

show chassis fabric summary (SRX5600 and SRX5800 devices with SRX5000 line SCB II
(SRX5K-SCBE) and SRX5K-RE-1800X4)

user@host> show chassis fabric summary


node0:
--------------------------------------------------------------------------
Plane State Uptime
0 Online 14 minutes, 10 seconds
1 Online 14 minutes, 5 seconds
2 Online 14 minutes
3 Online 13 minutes, 55 seconds
4 Spare 13 minutes, 50 seconds
5 Spare 13 minutes, 44 seconds

node1:
--------------------------------------------------------------------------
Plane State Uptime
0 Online 14 minutes, 7 seconds
868

1 Online 14 minutes, 2 seconds


2 Online 13 minutes, 57 seconds
3 Online 13 minutes, 51 seconds
4 Spare 13 minutes, 46 seconds
5 Spare 13 minutes, 41 seconds

Release Information

Command introduced in Junos OS Release 9.2.

RELATED DOCUMENTATION

show chassis fabric plane | 854


show chassis fabric plane-location | 862

show chassis hardware (View)

IN THIS SECTION

Syntax | 869

Description | 869

Options | 870

Required Privilege Level | 870

Output Fields | 870

show chassis hardware | 876

show chassis hardware (SRX4200) | 886

show chassis hardware (vSRX Virtual Firewall 3.0) | 887

show chassis hardware clei-models | 887

Release Information | 888


869

Syntax

show chassis hardware


<clei-models>
<detail | extensive>
<models>
<node(node-id | all | local | primary)>

Description

Display chassis hardware information.

Starting in Junos OS Release 20.1R1, when vSRX Virtual Firewall 3.0 performs resource management,
the vCPUs and RAM available to the instance are assigned based on what has been allocated prior to
launching the instance. A maximum of 32 cores will be assigned to SRXPFE, for flow processing. Any
allocation of cores in excess of 32 will automatically be assigned to the Routing Engine. For example, if
36 cores are allocated to the VM during the creation process, 32 cores are assigned for flow processing
and 4 cores will be assigned to the RE. For memory allocations, up to 64G of vRAM would be used by
the SRXPFE. Any allocated memory in excess of 64G would be assigned to system memory and would
not be used for maintaining flow sessions information.

Table 60: Recommended vCPU and vRAM Combinations

vCPU Number vRAM Size (G)

2 4

5 8

9 16

17 32

On a deployed vSRX Virtual Firewall, only memory scale up is supported. Scaling down memory on a
deployed vSRX Virtual Firewall, is not supported. If you need to scale down memory, then a fresh install
is required.
870

Options

• clei-models—(Optional) Display Common Language Equipment Identifier Code (CLEI) barcode and
model number for orderable field-replaceable units (FRUs).

• detail | extensive—(Optional) Display the specified level of output.

• models—(Optional) Display model numbers and part numbers for orderable FRUs.

• node—(Optional) For chassis cluster configurations, display chassis hardware information on a specific
node (device) in the cluster.

• node-id —Identification number of the node. It can be 0 or 1.

• local—Display information about the local node.

• primary—Display information about the primary node.

Required Privilege Level

view

Output Fields

Table 61 on page 870 lists the output fields for the show chassis hardware command. Output fields are
listed in the approximate order in which they appear.

Table 61: show chassis hardware Output Fields

Field Name Field Description

Item Chassis component—Information about the backplane; power supplies; fan


trays; Routing Engine; each Physical Interface Module (PIM)—reported as FPC
and PIC—and each fan, blower, and impeller.

Version Revision level of the chassis component.


871

Table 61: show chassis hardware Output Fields (Continued)

Field Name Field Description

Part Number Part number for the chassis component.

Serial Number Serial number of the chassis component. The serial number of the backplane is
also the serial number of the device chassis. Use this serial number when you
need to contact Juniper Networks Customer Support about the device chassis.

Assb ID or Assembly ID Identification number that describes the FRU hardware.

FRU model number Model number of FRU hardware component.

CLEI code Common Language Equipment Identifier code. This value is displayed only for
hardware components that use ID EEPROM format v2. This value is not
displayed for components that use ID EEPROM format v1.

EEPROM Version ID EEPROM version used by hardware component: 0x01 (version 1) or 0x02
(version 2).
872

Table 61: show chassis hardware Output Fields (Continued)

Field Name Field Description

Description Brief description of the hardware item:

• Type of power supply.

• Switch Control Board (SCB)

Starting with Junos OS Release 12.1X47-D15 and Junos OS Release


17.3R1, the SRX5K-SCBE (SCB2) is introduced.

• There are three SCB slots in SRX5800 devices. The third slot can be
used for an SCB or an FPC. When an SRX5K-SCB was used , the third
SCB slot was used as an FPC. SCB redundancy is provided in chassis
cluster mode.

• With an SCB2, a third SCB is supported. If a third SCB is plugged in, it


provides intra-chassis fabric redundancy.

• The Ethernet switch in the SCB2 provides the Ethernet connectivity


among all the FPCs and the Routing Engine. The Routing Engine uses
this connectivity to distribute forwarding and routing tables to the
FPCs. The FPCs use this connectivity to send exception packets to the
Routing Engine.

• Fabric connects all FPCs in the data plane. The Fabric Manager
executes on the Routing Engine and controls the fabric system in the
chassis. Packet Forwarding Engines on the FPC and fabric planes on
the SCB are connected through HSL2 channels.

• SCB2 supports HSL2 with both 3.11 Gbps and 6.22 Gbps (SerDes) link
speed and various HSL2 modes. When an FPC is brought online, the
link speed and HSL2 mode are determined by the type of FPC.

Starting with Junos OS Release 15.1X49-D10 and Junos OS Release


17.3R1, the SRX5K-SCB3 (SCB3) with enhanced midplane is introduced.

• All existing SCB software that is supported by SCB2 is supported on


SCB3.

• SRX5K-RE-1800X4 mixed Routing Engine use is not supported.


873

Table 61: show chassis hardware Output Fields (Continued)

Field Name Field Description

• SCB3 works with the SRX5K-MPC (IOC2), SRX5K-MPC3-100G10G


(IOC3), SRX5K-MPC3-40G10G (IOC3), and SRX5K-SPC-4-15-320
(SPC2) with current midplanes and the new enhanced midplanes.

• Mixed SCB use is not supported. If an SCB2 and an SCB3 are used, the
system will only power on the primary Routing Engine's SCB and will
power off the other SCBs. Only the SCB in slot 0 is powered on and a
system log is generated.

• SCB3 supports up to 400 Gbps per slot with old midplanes and up to
500 Gbps per slot with new midplanes.

• SCB3 supports fabric intra-chassis redundancy.

• SCB3 supports the same chassis cluster function as the SRX5K-SCB


(SCB1) and the SRX5K-SCBE (SCB2), except for in-service software
upgrade (ISSU) and in-service hardware upgrade (ISHU).

• SCB3 has a second external Ethernet port.

• Fabric bandwidth increasing mode is not supported.

Starting in Junos OS 19.3R1, SRX5K-SCB4 is supported on SRX5600 and


SRX5800 devices along with SRX5K-SPC3.

SRX5K-SCB4:

• Interoperate with SRX5K-RE3-128G, SRX5K-RE-1800X4, IOC2, IOC3,


IOC4, SPC2, and SPC3. SCB4 is compatible with all midplanes and
interoperate with existing PEMs, fan trays, and front panel displays.

• Does not interoperate with SCB, SCB2, and SCB3.

• Supports 480-Gbps link speed per slot.

• Supports 1-Gigabit Ethernet interfaces speed with SRX5K-RE-1800X4


and 1-Gigabit, 2.5-Gigabit, and 10-Gigabit Ethernet speeds with
SRX5K-RE3-128G.

• Support ISHU and ISSU in chassis cluster.


874

Table 61: show chassis hardware Output Fields (Continued)

Field Name Field Description

• Supports fabric bandwidth mode and redundant fabric mode on


SRX5600 and SRX5800 devices. The bandwidth mode is the new
default mode which is necessary to configure redundant mode in
setting up the chassis cluster successfully.

• Type of Flexible PIC Concentrator (FPC), Physical Interface Card (PIC),


Modular Interface Cards (MICs), and PIMs.

• IOCs

Starting with Junos OS Release 15.1X49-D10 and Junos OS Release


17.3R1, the SRX5K-MPC3-100G10G (IOC3) and the SRX5K-
MPC3-40G10G (IOC3) are introduced.

• IOC3 has two types of IOC3 MPCs, which have different built-in MICs:
the 24x10GE + 6x40GE MPC and the 2x100GE + 4x10GE MPC.

• IOC3 supports SCB3 and SRX5000 line backplane and enhanced


backplane.

• IOC3 can only work with SRX5000 line SCB2 and SCB3. If an SRX5000
line SCB is detected, IOC3 is offline, an FPC misconfiguration alarm is
raised, and a system log message is generated.

• IOC3 interoperates with SCB2 and SCB3.

• IOC3 interoperates with the SRX5K-SPC-4-15-320 (SPC2) and the


SRX5K-MPC (IOC2).

• The maximum power consumption for one IOC3 is 645W. An


enhanced power module must be used.

• The IOC3 does not support the following command to set a PIC to go
offline or online:

request chassis pic fpc-slot <fpc-slot> pic-slot <pic-slot> <offline |


online> .

• IOC3 supports 240 Gbps of throughput with the enhanced SRX5000


line backplane.

• Chassis cluster functions the same as for the SRX5000 line IOC2.
875

Table 61: show chassis hardware Output Fields (Continued)

Field Name Field Description

• IOC3 supports intra-chassis and inter-chassis fabric redundancy mode.

• IOC3 supports ISSU and ISHU in chassis cluster mode.

• IOC3 supports intra-FPC and and Inter-FPC Express Path (previously


known as services offloading) with IPv4.

• NAT of IPv4 and IPv6 in normal mode and IPv4 for Express Path mode.

• All four PICs on the 24x10GE + 6x40GE cannot be powered on. A


maximum of two PICs can be powered on at the same time.

Use the set chassis fpc <slot> pic <pic> power off command to
choose the PICs you want to power on.

Fabric bandwidth increasing mode is not supported on IOC3.

• SRX Clustering Module (SCM)

• Fan tray

Starting in Junos OS Release 19.3R1, the SRX5K-IOC4-10G and SRX5K-


IOC4-MRAT line cards are supported along with SRX5K-SPC3 on the
SRX5000 line devices.

SRX5K-IOC4-10G:

• Interoperates with SCB3, SCB4, SRX5K-RE-1800X4, SRX5K-


RE3-128G, SPC2, SPC3, IOC2,IOC3, and IOC4.

• Supports 480-Gbps speed.

• Supports 40X10GE Interfaces with SCB3.

• 40 10-Gigabit Ethernet port provides 10-Gigabit Ethernet MACsec


support.

• Supports reth and aggregated interfaces on the chassis cluster.

• Supports ISSU and logical system on the chassis cluster.

• Does not support SCB2.


876

Table 61: show chassis hardware Output Fields (Continued)

Field Name Field Description

• SRX5K-IOC4-MRAT with SCB3 supports 10-Gigabit, 40-Gigabit, and


100-Gigabit Ethernet Interfaces.

• For hosts, the Routing Engine type.

Starting with Junos OS Release 12.1X47-D15 and Junos OS Release


17.3R1, the SRX5K-RE-1800X4 Routing Engine is introduced.

• The SRX5K-RE-1800X4 has an Intel Quad core Xeon processor, 16 GB


of DRAM, and a 128-GB solid-state drive (SSD).

The number 1800 refers to the speed of the processor (1.8 GHz). The
maximum required power for this Routing Engine is 90W.

NOTE: The SRX5K-RE-1800X4 provides significantly better


performance than the previously used Routing Engine, even with a
single core.

Starting in Junos OS Release 19.3R1, SRX5K-RE3-128G Routing Engine is


supported along with SRX5K-SPC3 on the SRX5000 line devices.

SRX5K-RE3-128G:

• Provides improved control plane performance and scalability. SRX5K-


RE3-128G has Intel’s Haswell-EP based processor with six cores.

• Supports two 200G SSDs to store log files and 128-GB of memory for
storing routing and forwarding tables and for other routing engines.

• Interoperates with SCB3, SCB4, SRX5K-RE3-128G, SPC2, SPC3, IOC2,


IOC3, and IOC4.

• Does not support SCB2 and SRX5K-RE-1800X4.

show chassis hardware

show chassis hardware (SRX5800)

user@host> show chassis hardware


node0:
877

--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1267B0FAGA SRX5800
Midplane REV 42 760-063937 ACRL3065 Enhanced SRX5800
Backpl
ane
FPM Board REV 05 760-061272 CAHE4860 Front Panel Display
PDM Rev 01 740-063049 QCS2209509D Power Distribution
Modu
le
PEM 0 Rev 04 740-034724 QCS171002016 PS 4.1kW; 200-240V AC
i
n
PEM 1 Rev 11 740-027760 QCS1825N07S PS 4.1kW; 200-240V AC
i
n
Routing Engine 0 REV 01 750-095568 CALK8884 SRX5k RE-2000x6
Routing Engine 1 REV 01 750-095568 CADZ9076 SRX5k RE-2000x6
CB 0 REV 26 750-031391 CALV3002 SRX5k SCB4
CB 1 REV 26 750-031391 CALV3009 SRX5k SCB4
FPC 2 REV 28 750-073435 CALS4630 SPC3
CPU BUILTIN BUILTIN SRX5k vCPP Broadwell
PIC 0 BUILTIN BUILTIN SPU Cp-Flow
PIC 1 BUILTIN BUILTIN SPU Flow
FPC 3 REV 17 750-044175 CABE7777 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 4 REV 08 750-061262 CAFD8147 SRX5k IOC II
CPU REV 02 711-061263 CAFV7488 SRX5k MPC PMB
MIC 0 REV 03 750-055732 CAFV9369 20x 1GE(LAN) SFP
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 0 REV 02 740-011613 PNB1GJR SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) SFP
FPC 5 REV 10 750-062242 CAKX2328 SRX5k IOC3 2CGE+4XGE
PIC 0 BUILTIN BUILTIN 2x 10GE SFP+
Xcvr 0 REV 01 740-021308 ANA07RE SFP+-10G-SR
Xcvr 1 REV 01 740-031980 AQF0RBJ SFP+-10G-SR
PIC 1 BUILTIN BUILTIN 1x 100GE CFP2
PIC 2 BUILTIN BUILTIN 2x 10GE SFP+
878

Xcvr 0 REV 01 740-031980 AA1650304RF SFP+-10G-SR


Xcvr 1 REV 01 740-021308 AQ93BDK SFP+-10G-SR
PIC 3 BUILTIN BUILTIN 1x 100GE CFP2
FPC 8 REV 46 750-056519 CALC4514 SRX5k IOC4 MRAT
CPU REV 21 750-057177 CALC3494 SMPC PMB
PIC 0 BUILTIN BUILTIN MRATE-6xQSFPP-XGE-XLGE-CGE
Xcvr 0 REV 01 740-059437 000T20128 QSFP28-LPBK
Xcvr 1 REV 01 740-067443 1ACP13450KH QSFP+-40G-SR4
PIC 1 BUILTIN BUILTIN MRATE-6xQSFPP-XGE-XLGE-CGE
Xcvr 0 REV 01 740-059437 0000T3443 QSFP28-LPBK
Fan Tray 0 REV 06 740-035409 ACAE9390 Enhanced Fan Tray
Fan Tray 1 REV 06 740-035409 ACAE9386 Enhanced Fan Tray

node1:
--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1267B01AGA SRX5800
Midplane REV 42 760-063937 ACRL3068 Enhanced SRX5800 Backplane
FPM Board REV 05 760-061272 CAJX9988 Front Panel Display
PDM Rev 01 740-063049 QCS2209507A Power Distribution Module
PEM 0 Rev 11 740-027760 QCS1822N0EY PS 4.1kW; 200-240V AC in
PEM 1 Rev 03 740-034724 QCS17020203F PS 4.1kW; 200-240V AC in
Routing Engine 0 REV 01 750-095568 CALK8904 SRX5k RE-2000x6
Routing Engine 1 REV 01 750-095568 CADZ9076 SRX5k RE-2000x6
CB 0 REV 26 750-031391 CALV3010 SRX5k SCB4
CB 1 REV 26 750-031391 CALV3000 SRX5k SCB4
FPC 2 REV 28 750-073435 CAKZ9620 SPC3
CPU BUILTIN BUILTIN SRX5k vCPP Broadwell
PIC 0 BUILTIN BUILTIN SPU Cp-Flow
PIC 1 BUILTIN BUILTIN SPU Flow
FPC 3 REV 18 750-054877 CACH4082 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 4 REV 08 750-061262 CAFD8165 SRX5k IOC II
CPU REV 02 711-061263 CAFV7507 SRX5k MPC PMB
MIC 0 REV 03 750-055732 CAFV6603 20x 1GE(LAN) SFP
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 0 REV 01 740-011613 AM0805S8M4N SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) SFP
879

FPC 5 REV 03 750-062242 CAFZ2748 SRX5k IOC3 2CGE+4XGE


PIC 0 BUILTIN BUILTIN 2x 10GE SFP+
Xcvr 0 REV 01 740-021308 11T511100788 SFP+-10G-SR
Xcvr 1 REV 01 740-031980 AS92WJ0 SFP+-10G-SR
PIC 1 BUILTIN BUILTIN 1x 100GE CFP2
PIC 2 BUILTIN BUILTIN 2x 10GE SFP+
Xcvr 0 REV 01 740-031980 AA1650304EZ SFP+-10G-SR
Xcvr 1 REV 01 740-031980 ANS0EAR SFP+-10G-SR
PIC 3 BUILTIN BUILTIN 1x 100GE CFP2
FPC 8 REV 46 750-056519 CALC4526 SRX5k IOC4 MRAT
CPU REV 21 750-057177 CALF5727 SMPC PMB
PIC 0 BUILTIN BUILTIN MRATE-6xQSFPP-XGE-XLGE-CGE
Xcvr 1 REV 01 740-067443 1ACP13450L9 QSFP+-40G-SR4
PIC 1 BUILTIN BUILTIN MRATE-6xQSFPP-XGE-XLGE-CGE
Fan Tray 0 REV 06 740-035409 ACAE9298 Enhanced Fan Tray
Fan Tray 1 REV 06 740-035409 ACAE9314 Enhanced Fan Tray

{primary:node0}

show chassis hardware (SRX5600 and SRX5800 devices for SRX5K-MPC)

user@host> show chassis hardware


Hardware inventory:
Item Version Part number Serial number Description
Chassis JN12170EAAGA SRX 5800
Midplane REV 01 710-041799 ACAX3849 SRX 5800 Backplane
FPM Board REV 01 710-024632 CAAX7297 Front Panel Display
PDM Rev 03 740-013110 QCS170250DU Power Distribution Modu
le
PEM 0 Rev 03 740-034724 QCS17020203F PS 4.1kW; 200-240V AC i
n
PEM 1 Rev 03 740-034724 QCS17020203C PS 4.1kW; 200-240V AC i
n
PEM 2 Rev 04 740-034724 QCS17100200A PS 4.1kW; 200-240V AC i
n
PEM 3 Rev 03 740-034724 QCS17080200M PS 4.1kW; 200-240V AC i
n
Routing Engine 0 REV 11 740-023530 9012047437 SRX5k RE-13-20
CB 0 REV 09 710-024802 CAAX7202 SRX5k SCB
CB 1 REV 09 710-024802 CAAX7157 SRX5k SCB
FPC 0 REV 07 750-044175 CAAD0791 SRX5k SPC II
880

CPU BUILTIN BUILTIN SRX5k DPC PPC


PIC 0 BUILTIN BUILTIN SPU Cp
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 1 REV 07 750-044175 CAAD0751 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 2 REV 28 750-020751 CAAW1817 SRX5k DPC 4X 10GE
CPU REV 04 710-024633 CAAZ5269 SRX5k DPC PMB
PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN) RichQ
Xcvr 0 REV 02 740-014289 T10A00404 XFP-10G-SR
PIC 1 BUILTIN BUILTIN 1x 10GE(LAN/WAN) RichQ
PIC 2 BUILTIN BUILTIN 1x 10GE(LAN/WAN) RichQ
PIC 3 BUILTIN BUILTIN 1x 10GE(LAN/WAN) RichQ
FPC 6 REV 02 750-044175 ZY2552 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
FPC 9 REV 10 750-044175 CAAP5932 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 10 REV 22 750-043157 ZH8192 SRX5k IOC II CPU REV 08
711-043360 YX3879 SRX5k MPC PMB
MIC 0 REV 01 750-049488 YZ2084 10x 10GE SFP+
PIC 0 BUILTIN BUILTIN 10x 10GE SFP+
Xcvr 0 REV 01 740-031980 AMB0HG3 SFP+-10G-SR
Xcvr 1 REV 01 740-031980 AM20B6F SFP+-10G-SR
MIC 1 REV 19 750-049486 CAAH3504 1x 100GE CFP
PIC 2 BUILTIN BUILTIN 1x 100GE CFP
Xcvr 0 REV 01 740-035329 X000D375 CFP-100G-SR10
FPC 11 REV 07.04.07 750-043157 CAAJ8771 SRX5k IOC II CPU REV 08
711-043360 CAAJ3881 SRX5k MPC PMB
MIC 0 REV 19 750-049486 CAAH0979 1x 100GE CFP
PIC 0 BUILTIN BUILTIN 1x 100GE CFP
Xcvr 0 REV 01 740-035329 UP1020Z CFP-100G-SR10
MIC 1 REV 08 750-049487 CAAM1160 2x 40GE QSFP+
PIC 2 BUILTIN BUILTIN 2x 40GE QSFP+
Xcvr 0 REV 01 740-032986 QB151094 QSFP+-40G-SR4
881

Xcvr 1 REV 01 740-032986 QB160509 QSFP+-40G-SR4


Fan Tray 0 REV 04 740-035409 ACAE0875 Enhanced Fan Tray
Fan Tray 1 REV 04 740-035409 ACAE0876 Enhanced Fan Tray

show chassis hardware (with 20-Gigabit Ethernet MIC with SFP)

user@host> show chassis hardware


Hardware inventory:
Item Version Part number Serial number Description
Chassis JN108DA5AAGA SRX 5800
Midplane REV 02 710-013698 TR0037 SRX 5600 Midplane
FPM Board REV 02 710-014974 JY4635 Front Panel Display
PDM Rev 02 740-013110 QCS10465005 Power Distribution Module
PEM 0 Rev 03 740-023514 QCS11154040 PS 1.7kW; 200-240VAC in
PEM 2 Rev 02 740-023514 QCS10504014 PS 1.7kW; 200-240VAC in
Routing Engine 0 REV 05 740-015113 1000681023 RE-S-1300
CB 0 REV 05 710-013385 JY4775 SRX5k SCB
FPC 1 REV 17 750-020751 WZ6349 SRX5k DPC 4X 10GE
CPU REV 02 710-024633 WZ0718 SRX5k DPC PMB
PIC 0 BUILTIN BUILTIN 1x 10GE(LAN/WAN) RichQ
Xcvr 0 NON-JNPR C724XM088 XFP-10G-SR
PIC 1 BUILTIN BUILTIN 1x 10GE(LAN/WAN) RichQ
Xcvr 0 REV 02 740-011571 C831XJ08S XFP-10G-SR
PIC 2 BUILTIN BUILTIN 1x 10GE(LAN/WAN) RichQ
PIC 3 BUILTIN BUILTIN 1x 10GE(LAN/WAN) RichQ
FPC 3 REV 22 750-043157 ZH8189 SRX5k IOC II
CPU REV 06 711-043360 YX3912 SRX5k MPC PMB
MIC 0 REV 01 750-055732 CACF9115 20x 1GE(LAN) SFP
PIC 0 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 2 REV 02 740-013111 B358549 SFP-T
Xcvr 9 REV 02 740-011613 PNB1FQS SFP-SX
PIC 1 BUILTIN BUILTIN 10x 1GE(LAN) SFP
Xcvr 9 REV 02 740-011613 PNB1FFF SFP-SX
FPC 5 REV 01 750-027945 JW9665 SRX5k FIOC
CPU
FPC 8 REV 08 750-023996 XA7234 SRX5k SPC
CPU REV 02 710-024633 XA1599 SRX5k DPC PMB
PIC 0 BUILTIN BUILTIN SPU Cp-Flow
PIC 1 BUILTIN BUILTIN SPU Flow
882

Fan Tray 0 REV 03 740-014971 TP0902 Fan Tray


Fan Tray 1 REV 01 740-014971 TP0121 Fan Tray

show chassis hardware (SRX5600 and SRX5800 devices with SRX5000 line SRX5K-SCBE
[SCB2] and SRX5K-RE-1800X4 [RE2])

user@host> show chassis hardware


node0:
--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1251EA1AGB SRX5600
Midplane REV 01 760-063936 ACRE2657 Enhanced SRX5600 Midplane
FPM Board REV 01 710-024631 CABY3551 Front Panel Display
PEM 0 Rev 03 740-034701 QCS13380901P PS 1.4-2.6kW; 90-264V AC in
PEM 1 Rev 03 740-034701 QCS133809019 PS 1.4-2.6kW; 90-264V AC in
Routing Engine 0 REV 02 740-056658 9009210105 SRX5k RE-1800X4
Routing Engine 1 REV 02 740-056658 9013115551 SRX5k RE-1800X4
CB 0 REV 01 750-062257 CADW3663 SRX5k SCB3
CB 1 REV 01 750-062257 CADZ3263 SRX5k SCB3
FPC 0 REV 18 750-054877 CABG6043 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Cp
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 1 REV 01 750-062243 CAEE5918 SRX5k IOC3 24XGE+6XLG
CPU REV 02 711-062244 CADX8509 RMPC PMB
PIC 0 BUILTIN BUILTIN 12x 10GE SFP+
Xcvr 0 REV 01 740-031980 273363A01891 SFP+-10G-SR
Xcvr 1 REV 01 740-031980 273363A01915 SFP+-10G-SR
Xcvr 2 REV 01 740-031980 ANA0BK6 SFP+-10G-SR
Xcvr 3 REV 01 740-031980 AP407GA SFP+-10G-SR
Xcvr 9 REV 01 740-021308 MUC20G1 SFP+-10G-SR
PIC 1 BUILTIN BUILTIN 12x 10GE SFP+
PIC 2 BUILTIN BUILTIN 3x 40GE QSFP+
PIC 3 BUILTIN BUILTIN 3x 40GE QSFP+
WAN MEZZ REV 15 750-049136 CAEE5845 MPC5E 24XGE OTN Mezz
FPC 3 REV 11 750-043157 CACL7452 SRX5k IOC II
CPU REV 04 711-043360 CACP1977 SRX5k MPC PMB
MIC 0 REV 04 750-049488 CABL4759 10x 10GE SFP+
883

PIC 0 BUILTIN BUILTIN 10x 10GE SFP+


Xcvr 0 REV 01 740-021308 CF36KM0SY SFP+-10G-SR
Xcvr 1 REV 01 740-021308 MUC0MF2 SFP+-10G-SR
Xcvr 2 REV 01 740-021308 CF36KM01S SFP+-10G-SR
Xcvr 3 REV 01 740-021308 MUC229N SFP+-10G-SR
FPC 5 REV 07 750-044175 CAAD0764 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
Fan Tray Enhanced Fan Tray

node1:
--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN124FE77AGB SRX5600
Midplane REV 01 760-063936 ACRE2970 Enhanced SRX5600 Midplane
FPM Board REV 01 710-024631 CABY3552 Front Panel Display
PEM 0 Rev 03 740-034701 QCS133809028 PS 1.4-2.6kW; 90-264V AC in
PEM 1 Rev 03 740-034701 QCS133809027 PS 1.4-2.6kW; 90-264V AC in
Routing Engine 0 REV 02 740-056658 9009218294 SRX5k RE-1800X4
Routing Engine 1 REV 02 740-056658 9013104758 SRX5k RE-1800X4
CB 0 REV 01 750-062257 CAEB8180 SRX5k SCB3
CB 1 REV 01 750-062257 CADZ3334 SRX5k SCB3
FPC 0 REV 18 750-054877 CACJ9834 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Cp
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 1 REV 01 750-062243 CAEB0981 SRX5k IOC3 24XGE+6XLG
CPU REV 02 711-062244 CAEA4644 RMPC PMB
PIC 0 BUILTIN BUILTIN 12x 10GE SFP+
Xcvr 0 REV 01 740-031980 AP41BLH SFP+-10G-SR
Xcvr 1 REV 01 740-031980 AQ400SL SFP+-10G-SR
Xcvr 2 REV 01 740-031980 AP422LJ SFP+-10G-SR
Xcvr 3 REV 01 740-021308 AMG0RBT SFP+-10G-SR
Xcvr 9 REV 01 740-021308 MUC2FRG SFP+-10G-SR
PIC 1 BUILTIN BUILTIN 12x 10GE SFP+
PIC 2 BUILTIN BUILTIN 3x 40GE QSFP+
PIC 3 BUILTIN BUILTIN 3x 40GE QSFP+
884

WAN MEZZ REV 15 750-049136 CAEA4837 MPC5E 24XGE OTN Mezz


FPC 3 REV 11 750-043157 CACA8784 SRX5k IOC II
CPU REV 04 711-043360 CACA8820 SRX5k MPC PMB
MIC 0 REV 05 750-049488 CADF0521 10x 10GE SFP+
PIC 0 BUILTIN BUILTIN 10x 10GE SFP+
Xcvr 0 REV 01 740-030658 AD1130A00PV SFP+-10G-USR
Xcvr 1 REV 01 740-031980 AN40MVV SFP+-10G-SR
Xcvr 2 REV 01 740-021308 CF36KM37B SFP+-10G-SR
Xcvr 3 REV 01 740-021308 AD153830DSZ SFP+-10G-SR
MIC 1 REV 01 750-049487 CABB5961 2x 40GE QSFP+
PIC 2 BUILTIN BUILTIN 2x 40GE QSFP+
Xcvr 1 REV 01 740-032986 QB160513 QSFP+-40G-SR4
FPC 5 REV 02 750-044175 ZY2569 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
Fan Tray Enhanced Fan Tray

show chassis hardware (SRX5400, SRX5600, and SRX5800 devices with SRX5000 line
SRX5K-SCB3 [SCB3] with enhanced midplanes and SRX5K-MPC3-100G10G [IOC3] or
SRX5K-MPC3-40G10G [IOC3])

user@host> show chassis hardware


node0:
--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN1250870AGB SRX5600
Midplane REV 01 760-063936 ACRE2578 Enhanced SRX5600
Midplane

FPM Board REV 02 710-017254 KD9027 Front Panel Display


PEM 0 Rev 03 740-034701 QCS13090900T PS 1.4-2.6kW; 90-264V
A
C in
PEM 1 Rev 03 740-034701 QCS13090904T PS 1.4-2.6kW; 90-264V
A
C in
Routing Engine 0 REV 01 740-056658 9009196496 SRX5k RE-1800X4
885

CB 0 REV 01 750-062257 CAEC2501 SRX5k SCB3


FPC 0 REV 10 750-056758 CADC8067 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Cp
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 2 REV 01 750-062243 CAEE5924 SRX5k IOC3 24XGE+6XLG
CPU REV 01 711-062244 CAEB4890 SRX5k IOC3 PMB
PIC 0 BUILTIN BUILTIN 12x 10GE SFP+
PIC 1 BUILTIN BUILTIN 12x 10GE SFP+
PIC 2 BUILTIN BUILTIN 3x 40GE QSFP+
Xcvr 0 REV 01 740-038623 MOC13156230449 QSFP+-40G-CU1M
Xcvr 2 REV 01 740-038623 MOC13156230449 QSFP+-40G-CU1M
PIC 3 BUILTIN BUILTIN 3x 40GE QSFP+
WAN MEZZ REV 01 750-062682 CAEE5817 24x 10GE SFP+ Mezz
FPC 4 REV 11 750-043157 CACY1595 SRX5k IOC II
CPU REV 04 711-043360 CACZ8879 SRX5k MPC PMB
MIC 1 REV 04 750-049488 CACM6062 10x 10GE SFP+
PIC 2 BUILTIN BUILTIN 10x 10GE SFP+
Xcvr 7 REV 01 740-021308 AD1439301TU SFP+-10G-SR
Xcvr 8 REV 01 740-021308 AD1439301SD SFP+-10G-SR
Xcvr 9 REV 01 740-021308 AD1439301TS SFP+-10G-SR
FPC 5 REV 05 750-044175 ZZ1371 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
Fan Tray Enhanced Fan Tray

node1:
--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number Serial number Description
Chassis JN124FEC0AGB SRX5600
Midplane REV 01 760-063936 ACRE2946 Enhanced SRX5600 Midplane
FPM Board test 710-017254 test Front Panel Display
PEM 0 Rev 01 740-038514 QCS114111003 DC 2.6kW Power Entry Module
PEM 1 Rev 01 740-038514 QCS12031100J DC 2.6kW Power Entry Module
Routing Engine 0 REV 01 740-056658 9009186342 SRX5k RE-1800X4
CB 0 REV 01 750-062257 CAEB8178 SRX5k SCB3
FPC 0 REV 07 750-044175 CAAD0769 SRX5k SPC II
886

CPU BUILTIN BUILTIN SRX5k DPC PPC


PIC 0 BUILTIN BUILTIN SPU Cp
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
FPC 4 REV 11 750-043157 CACY1592 SRX5k IOC II
CPU REV 04 711-043360 CACZ8831 SRX5k MPC PMB
MIC 1 REV 04 750-049488 CACN0239 10x 10GE SFP+
PIC 2 BUILTIN BUILTIN 10x 10GE SFP+
Xcvr 7 REV 01 740-031980 ARN23HW SFP+-10G-SR
Xcvr 8 REV 01 740-031980 ARN2FVW SFP+-10G-SR
Xcvr 9 REV 01 740-031980 ARN2YVM SFP+-10G-SR
FPC 5 REV 10 750-056758 CADA8736 SRX5k SPC II
CPU BUILTIN BUILTIN SRX5k DPC PPC
PIC 0 BUILTIN BUILTIN SPU Flow
PIC 1 BUILTIN BUILTIN SPU Flow
PIC 2 BUILTIN BUILTIN SPU Flow
PIC 3 BUILTIN BUILTIN SPU Flow
Fan Tray Enhanced Fan Tray

show chassis hardware (SRX4200)

command-name

user@host> show chassis hardware

Hardware inventory:
Item Version Part number Serial number Description
Chassis DK2816AR0020 SRX4200
Mainboard REV 01 650-071675 16061032317 SRX4200
Routing Engine 0 BUILTIN BUILTIN SRX Routing Engine
FPC 0 BUILTIN BUILTIN FEB
PIC 0 BUILTIN BUILTIN 8x10G-SFP
Xcvr 0 REV 01 740-038153 MOC11511530020 SFP+-10G-CU3M
Xcvr 1 REV 01 740-038153 MOC11511530020 SFP+-10G-CU3M
Xcvr 2 REV 01 740-038153 MOC11511530020 SFP+-10G-CU3M
Xcvr 3 REV 01 740-038153 MOC11511530020 SFP+-10G-CU3M
Xcvr 4 REV 01 740-021308 04DZ06A00364 SFP+-10G-SR
Xcvr 5 REV 01 740-031980 233363A03066 SFP+-10G-SR
887

Xcvr 6 REV 01 740-021308 AL70SWE SFP+-10G-SR


Xcvr 7 REV 01 740-031980 ALN0N6C SFP+-10G-SR
Xcvr 8 REV 01 740-030076 APF16220018NK1 SFP+-10G-CU1M
Power Supply 0 REV 04 740-041741 1GA26241849 JPSU-650W-AC-AFO
Power Supply 1 REV 04 740-041741 1GA26241846 JPSU-650W-AC-AFO
Fan Tray 0 SRX4200 0, Front to Back Airflow - AFO
Fan Tray 1 SRX4200 1, Front to Back Airflow - AFO
Fan Tray 2 SRX4200 2, Front to Back Airflow - AFO
Fan Tray 3 SRX4200 3, Front to Back Airflow - AFO

show chassis hardware (vSRX Virtual Firewall 3.0)

command-name

user@host> show chassis hardware


Hardware inventory:
Item Version Part number Serial number Description
Chassis 806dddb1a141 VSRX
Midplane
System IO
Routing Engine VSRX-2CPU-8G memory
FPC 0 FPC
PIC 0 VSRX DPDK GE
Power Supply 0

show chassis hardware clei-models

show chassis hardware clei-models (SRX5600 and SRX5800 devices with SRX5000 line
SRX5K-SCBE [SCB2] and SRX5K-RE-1800X4 [RE2])

user@host> show chassis hardware clei-models node 1


node1:
--------------------------------------------------------------------------
Hardware inventory:
Item Version Part number CLEI code FRU model number
888

Midplane REV 01 710-024803 SRX5800-BP-A


FPM Board REV 01 710-024632 SRX5800-CRAFT-A
PEM 0 Rev 04 740-034724 SRX5800-PWR-4100-AC
PEM 1 Rev 05 740-034724 SRX5800-PWR-4100-AC
Routing Engine 0 REV 01 740-056658 COUCATTBAA SRX5K-RE-1800X4
CB 0 REV 01 750-056587 COUCATSBAA SRX5K-SCBE
CB 1 REV 01 750-056587 COUCATSBAA SRX5K-SCBE
CB 2 REV 01 750-056587 COUCATSBAA SRX5K-SCBE
FPC 0 REV 18 750-054877 COUCATLBAA SRX5K-SPC-4-15-320
CPU BUILTIN
FPC 1 REV 18 750-054877 COUCATLBAA SRX5K-SPC-4-15-320
CPU BUILTIN
FPC 2 REV 18 750-054877 COUCATLBAA SRX5K-SPC-4-15-320
CPU BUILTIN
FPC 3 REV 11 750-043157 COUIBCWBAA SRX5K-MPC
MIC 0 REV 05 750-049486 COUIBCYBAA SRX-MIC-1X100G-CFP
MIC 1 REV 04 750-049488 COUIBCXBAA SRX-MIC-10XG-SFPP
FPC 4 REV 18 750-054877 COUCATLBAA SRX5K-SPC-4-15-320
CPU BUILTIN
FPC 7 REV 18 750-054877 COUCATLBAA SRX5K-SPC-4-15-320
CPU BUILTIN
FPC 8 REV 11 750-043157 COUIBCWBAA SRX5K-MPC
MIC 0 REV 05 750-049486 COUIBCYBAA SRX-MIC-1X100G-CFP
FPC 9 REV 18 750-054877 COUCATLBAA SRX5K-SPC-4-15-320
CPU BUILTIN
FPC 10 REV 18 750-054877 COUCATLBAA SRX5K-SPC-4-15-320
CPU BUILTIN
Fan Tray 0 REV 04 740-035409 SRX5800-HC-FAN
Fan Tray 1 REV 04 740-035409 SRX5800-HC-FAN

Release Information

Command introduced in Junos OS Release 9.2. Command modified in Junos OS Release 9.2 to include
node option.

RELATED DOCUMENTATION

Understanding Traffic Processing on Security Devices


Interface Naming Conventions
889

show chassis routing-engine (View)

IN THIS SECTION

Syntax | 889

Description | 889

Required Privilege Level | 889

Output Fields | 890

Sample Output | 891

Sample Output | 892

Sample Output | 892

Sample Output | 893

Sample Output | 894

Release Information | 895

Syntax

show chassis routing-engine

Description

Display the Routing Engine status of the chassis cluster.

Required Privilege Level

view
890

Output Fields

Table 62 on page 890 lists the output fields for the show chassis routing-engine command. Output fields
are listed in the approximate order in which they appear.

Table 62: show chassis routing-engine Output Fields

Field Name Field Description

Temperature Routing Engine temperature. (Not available for vSRX Virtual Firewall
deployments.)

CPU temperature CPU temperature. (Not available for vSRX Virtual Firewall deployments.)

Total memory Total memory available on the system.

NOTE: Starting with Junos OS Release 15.1x49-D70 and Junos OS Release


17.3R1, there is a change in the method for calculating the memory utilization
by a Routing Engine. The inactive memory is now subtracted from the total
available memory. There is thus, a decrease in the reported value for used
memory; as the inactive memory is now considered as free.

Control plane memory Memory available for the control plane.

Data plane memory Memory reserved for data plane processing.

CPU utilization Current CPU utilization statistics on the control plane core.

User Current CPU utilization in user mode on the control plane core.

Background Current CPU utilization in nice mode on the control plane core.

Kernel Current CPU utilization in kernel mode on the control plane core.

Interrupt Current CPU utilization in interrupt mode on the control plane core.

Idle Current CPU utilization in idle mode on the control plane core.
891

Table 62: show chassis routing-engine Output Fields (Continued)

Field Name Field Description

Model Routing Engine model.

Start time Routing Engine start time.

Uptime Length of time the Routing Engine has been up (running) since the last start.

Last reboot reason Reason for the last reboot of the Routing Engine.

Load averages The average number of threads waiting in the run queue or currently
executing over 1-, 5-, and 15-minute periods.

Sample Output

show chassis routing-engine (Sample 1 - SRX550M)

user@host> show chassis routing-engine


Routing Engine status:
Temperature 38 degrees C / 100 degrees F
CPU temperature 36 degrees C / 96 degrees F
Total memory 512 MB Max 435 MB used ( 85 percent)
Control plane memory 344 MB Max 296 MB used ( 86 percent)
Data plane memory 168 MB Max 138 MB used ( 82 percent)
CPU utilization:
User 8 percent
Background 0 percent
Kernel 4 percent
Interrupt 0 percent
Idle 88 percent
Model RE-SRX5500-LOWMEM
Serial ID AAAP8652
Start time 2009-09-21 00:04:54 PDT
Uptime 52 minutes, 47 seconds
892

Last reboot reason 0x200:chassis control reset


Load averages: 1 minute 5 minute 15 minute
0.12 0.15 0.10

Sample Output

show chassis routing-engine (Sample 2 - vSRX Virtual Firewall)

user@host> show chassis routing-engine


Routing Engine status:
Total memory 1024 MB Max 358 MB used ( 35 percent)
Control plane memory 1024 MB Max 358 MB used ( 35 percent)
5 sec CPU utilization:
User 2 percent
Background 0 percent
Kernel 4 percent
Interrupt 6 percent
Idle 88 percent
Model VSRX RE
Start time 2015-03-03 07:04:18 UTC
Uptime 2 days, 11 hours, 51 minutes, 11 seconds
Last reboot reason Router rebooted after a normal shutdown.
Load averages: 1 minute 5 minute 15 minute
0.07 0.04 0.06

Sample Output

show chassis routing-engine (Sample 3- SRX5400)

user@host> show chassis routing-engine


Routing Engine status:
Slot 0:
Current state Master
Election priority Master (default)
Temperature 31 degrees C / 87 degrees F
CPU temperature 31 degrees C / 87 degrees F
893

DRAM 16323 MB (16384 MB installed)


Memory utilization 10 percent
5 sec CPU utilization:
User 2 percent
Background 0 percent
Kernel 12 percent
Interrupt 1 percent
Idle 85 percent
Model RE-S-1800x4
Serial ID 9016272401
Start time 2019-07-08 01:17:10 PDT
Uptime 2 minutes, 43 seconds
Last reboot reason Router rebooted after a normal shutdown.
Load averages: 1 minute 5 minute 15 minute
0.63 0.52 0.24

Sample Output

show chassis routing-engine (Sample 4- SRX4100)

user@host> show chassis routing-engine


Routing Engine status:
Temperature 29 degrees C / 84 degrees F
CPU temperature 29 degrees C / 84 degrees F
Total memory 1954 MB Max 567 MB used ( 29 percent)
Memory utilization 24 percent
5 sec CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
1 min CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
5 min CPU utilization:
894

User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
15 min CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
Model SRX Routing Engine
Serial ID BUILTIN
Uptime 17 days, 5 hours, 1 minute, 52 seconds
Last reboot reason 0x4000:VJUNOS reboot
Load averages: 1 minute 5 minute 15 minute
0.00 0.00 0.00

The Total memory 64 GB is distributed between the routing engine in the form of virtual machine for
the TVP platforms (SRX1500, SRX4100, SRX4200) and the rest for the packet forwarding engine (PFE).
TVP has a different architecture differentiating PFE from Junos and additional API compatibility. The
above mentioned devices are the only ones with this TVP architecture in SRX. The show chassis routing-
engine command displays only the Routing Engine memory.

Sample Output

show chassis routing-engine (Sample 5- SRX1500)

user@host> show chassis routing-engine


Routing Engine status:
Temperature 42 degrees C / 107 degrees F
CPU temperature 42 degrees C / 107 degrees F
Total memory 1954 MB Max 528 MB used ( 27 percent)
Memory utilization 23 percent
5 sec CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 100 percent
895

1 min CPU utilization:


User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 99 percent
5 min CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 99 percent
15 min CPU utilization:
User 0 percent
Background 0 percent
Kernel 0 percent
Interrupt 0 percent
Idle 96 percent
Model SRX Routing Engine
Serial ID BUILTIN
Uptime 52 minutes, 27 seconds
Last reboot reason 0x4000:VJUNOS reboot
Load averages: 1 minute 5 minute 15 minute
0.00 0.00 0.00

Release Information

Command introduced in Junos OS Release 9.5.

RELATED DOCUMENTATION

cluster (Chassis) | 606


request system snapshot (Maintenance)
896

show chassis reswatch

IN THIS SECTION

Syntax | 896

Description | 896

Required Privilege Level | 896

Output Fields | 896

Sample Output | 897

Release Information | 898

Syntax

show chassis reswatch-config

Description

Display resource usage statistics report. By default, reswatch only logs resource usages when the
monitored resource entered its orange zone.

Required Privilege Level

Output Fields

Table 63 on page 897 lists the output fields for the show chassis reswatch-config command. Output fields
are listed in the approximate order in which they appear.
897

Table 63: Show chassis reswatch-config

Field Name Field Description

Reswatch Enable or Disable.

CPU statistics count CPU statistics count value.

Junos statistics count Junos kernel statistics count value.

Red Zone Enable or Disable.

Red Zone CPU threshold Red zone CPU threshold value

Red Zone Junos threshold Red zone Junos threshold vlaue

Red Zone SNMP Enable or Disable.

Orange Zone Enable or Disable.

Orange Zone threshold Orange zone threshold value.

Sample Output

show chassis reswatch-config

user@host> show chassis reswatch-config

Reswatch: Enable
CPU statistics count: 0
Junos statistics count: 0
Red Zone: Enable
Red Zone CPU threshold: 15
Red Zone Junos threshold: 60
898

Red Zone SNMP: Enable


Orange Zone: Enable
Orange Zone threshold: 30

Release Information

Command introduced in Junos OS Release 20.4R1.

RELATED DOCUMENTATION

resource-watch | 699

show chassis scb-ha-port

IN THIS SECTION

Syntax | 898

Description | 899

Required Privilege Level | 899

Output Fields | 899

Sample Output | 901

Release Information | 903

Syntax

show chassis scb-ha-port statistics


899

Description

On SRX5400, SRX5600, and SRX5800 devices, this command displays information about switch control
board (SCB) HA control port 0 small form-factor pluggable (SFP) of the local node in chassis cluster. The
supported SCB versions are SRX5K SCB3 and SCB4 and SFP types are SFPP-10GE-LR and SFPP-10GE-
SR.

Required Privilege Level

view

Output Fields

Table 1 lists the output fields for the show chassis scb-ha-port statistics command.

Table 64: SCB HA Port Statistics

Field Name Field Description

Control ports optics • Port—Specifies control port number.


basic information
• Cable type—Specifies the type of cable.

• Fiber type—Specifies the fiber type.

• Xcvr vendor—Specifies the vendor details.

• Xcvr vendor part number—Specifies the part number.

• Wave-length—Specifies the wave length.

• Xcvr Firmware—Specifies the firmware version.

• JNPR Rev—Specifies the revision number.

• MSA Version—Specifies the MSA version.


900

Table 64: SCB HA Port Statistics (Continued)

Field Name Field Description

Control ports optics • Laser bias current—Specifies the power details.


diagnostics
information: Control • Laser output power—Specifies the power details.
port 0
• Module temperature—Specifies the power details.

• Module voltage—Specifies the power details.

• Laser receiver power—Specifies the power details.

• Alarm/warning flags implemented—Displays alarm On or Off status.

• Laser bias current high alarm / low alarm / high warning / low warning—Displays
alarm On or Off status.

• Laser output power high alarm / low alarm / high warning / low warning—Displays
alarm On or Off status

• Module temperature high alarm / low alarm / high warning / low warning—Displays
alarm On or Off status.

• Module voltage high alarm / low alarm / high warning / low warning—Displays alarm
On or Off status.

• Laser rx power high alarm / low alarm / high warning / low warning—Displays alarm
On or Off status.

• Laser bias current high alarm threshold—Specifies the power details.

• Laser bias current low alarm threshold—Specifies the power details.

• Laser bias current high warning threshold—Specifies the power details.

• Laser bias current low warning threshold—Specifies the power details.

• Laser output power high alarm threshold—Specifies the power details.

• Laser output power low alarm threshold—Specifies the power details.

• Laser output power high warning threshold—Specifies the power details.

• Laser output power low warning threshold—Specifies the power details.


901

Table 64: SCB HA Port Statistics (Continued)

Field Name Field Description

• Module temperature high alarm threshold—Specifies the power details.

• Module temperature low alarm threshold—Specifies the power details.

• Module temperature high warning threshold—Specifies the power details.

• Module temperature low warning threshold—Specifies the power details.

• Module voltage high alarm threshold—Specifies the power details.

• Module voltage low alarm threshold—Specifies the power details.

• Module voltage high warning threshold—Specifies the power details.

• Module voltage low warning threshold—Specifies the power details.

• Laser rx power high alarm threshold—Specifies the power details.

• Laser rx power low alarm threshold—Specifies the power details.

• Laser rx power high warning threshold—Specifies the power details.

• Laser rx power low warning threshold—Specifies the power details.

Sample Output

show chassis scb-ha-port statistics

user@host> show chassis scb-ha-port statistics

Control ports optics basic information:


Fiber Xcvr vendor Wave-
Xcvr JNPR MSA
Port Cable type type Xcvr vendor part number length
Firmware Rev Version
902

0 10G Base-SR MM FINISAR CORP. FTLX8571D3BCL-J1 850nm


0.0 REV 01 SFF-8472 ver 10.2

Control ports optics diagnostics information:


Control port 0:
Laser bias current : 7.778 mA
Laser output power : 0.5914 mW / -2.28 dBm
Module temperature : 32.57 degrees C /
90.63 degrees F
Module voltage : 3.2880 V
Laser receiver power : 0.4990 mW / -3.02 dBm
Alarm/warning flags implemented : On
Laser bias current high alarm / low alarm / high warning / low warning : Off / Off / Off / Off
Laser output power high alarm / low alarm / high warning / low warning : Off / Off / Off / Off
Module temperature high alarm / low alarm / high warning / low warning : Off / Off / Off / Off
Module voltage high alarm / low alarm / high warning / low warning : Off / Off / Off / Off
Laser rx power high alarm / low alarm / high warning / low warning : Off / Off / Off / Off
Laser bias current high alarm threshold : 13.200 mA
Laser bias current low alarm threshold : 4.000 mA
Laser bias current high warning threshold : 12.600 mA
Laser bias current low warning threshold : 5.000 mA
Laser output power high alarm threshold : 1.0000 mW / 0.00 dBm
Laser output power low alarm threshold : 0.2512 mW / -6.00 dBm
Laser output power high warning threshold : 0.7943 mW / -1.00 dBm
Laser output power low warning threshold : 0.3162 mW / -5.00 dBm
Module temperature high alarm threshold : 78.00 degrees C /
172.40 degrees F
Module temperature low alarm threshold : -13.00 degrees C /
8.60 degrees F
Module temperature high warning threshold : 73.00 degrees C /
163.40 degrees F
Module temperature low warning threshold : -8.00 degrees C /
17.60 degrees F
Module voltage high alarm threshold : 3.7000 V
Module voltage low alarm threshold : 2.9000 V
Module voltage high warning threshold : 3.6000 V
Module voltage low warning threshold : 3.0000 V
Laser rx power high alarm threshold : 1.0000 mW / 0.00 dBm
Laser rx power low alarm threshold : 0.0100 mW / -20.00 dBm
Laser rx power high warning threshold : 0.7943 mW / -1.00 dBm
Laser rx power low warning threshold : 0.0158 mW / -18.01 dBm
903

Release Information

Command introduced in Junos OS Release 23.2R1.

RELATED DOCUMENTATION

Chassis Cluster Dual Control Links | 172

show chassis temperature-thresholds

IN THIS SECTION

Syntax | 903

Description | 903

Required Privilege Level | 904

Output Fields | 904

Sample Output | 905

Release Information | 906

Syntax

show chassis temperature-thresholds

Description

Display chassis temperature threshold settings, in degrees Celsius.


904

Required Privilege Level

View

Output Fields

Table 65 on page 904 lists the output fields for the show chassis temperature-thresholds command. Output
fields are listed in the approximate order in which they appear.

Table 65: show chassis temperature-thresholds Output Fields

Field name Field Description

Item Chassis component. If per FRU per slot thresholds are configured, the components about
which information is displayed include the chassis, the Routing Engines, FPCs, and FEBs. If
per FRU per slot thresholds are not configured, the components about which information is
displayed include the chassis and the Routing Engines.

Chassis Default Default values of the chassis in degrees Celsius.

Routing Engine Default values of the routing engine in degrees Celsius.

Fan speed The fan speed changes at the threshold when going from a low speed to a higher speed.
When the fan speed changes from a higher speed to a lower speed, the temperature
changes two degrees below the threshold.

Temperature threshold settings, in degrees Celsius, for the fans to operate at normal and
high speeds.

• Normal—The fans operate at normal speed if the component is at or below this


temperature and all the fans are present and functioning normally.

• High—The fans operate at high speed if the component has exceeded this temperature
or a fan has failed or is missing.

An alarm is not triggered until the temperature exceeds the threshold settings for a yellow
alarm or a red alarm.
905

Table 65: show chassis temperature-thresholds Output Fields (Continued)

Field name Field Description

Yellow alarm Temperature threshold settings, in degrees Celsius, that trigger a yellow alarm.

• Normal—The temperature that must be exceeded on the component to trigger a yellow


alarm when the fans are running at full speed.

• Bad fan—The temperature that must be exceeded on the component to trigger a yellow
alarm when one or more fans have failed or are missing.

Red alarm Temperature threshold settings, in degrees Celsius, that trigger a red alarm.

• Normal—The temperature that must be exceeded on the component to trigger a red


alarm when the fans are running at full speed.

• Bad fan—The temperature that must be exceeded on the component to trigger a red
alarm when one or more fans have failed or are missing.

Fire shutdown Temperature threshold settings, in degrees Celsius, for the device to shut down.

Sample Output

show chassis temperature-thresholds

user@host> show chassis temperature-thresholds


Fan speed Yellow alarm Red alarm Fire
Shutdown
(degrees C) (degrees C) (degrees C)
(degrees C)
Item Normal High Normal Bad fan Normal Bad fan Normal
Chassis default 48 54 65 55 75 65 100
Routing Engine 0 70 80 95 95 110 110 112
FPC 0 55 60 75 65 90 80 95
FPC 2 55 60 75 65 90 80 95
906

Release Information

Command introduced in Junos OS Release 9.0

show configuration chassis cluster traceoptions

IN THIS SECTION

Syntax | 906

Description | 906

Required Privilege Level | 906

Output Fields | 907

Sample Output | 907

Release Information | 907

Syntax

show configuration chassis cluster traceoptions

Description

Display tracing options for the chassis cluster redundancy process.

Required Privilege Level

view
907

Output Fields

Table 66 on page 907 lists the output fields for the show configuration chassis cluster traceoptions
command. Output fields are listed in the approximate order in which they appear.

Table 66: show configuration chassis cluster traceoptions Output Fields

Field Name Field Description

file Name of the file that receives the output of the tracing operation.

size Size of each trace file.

files Maximum number of trace files.

Sample Output

show configuration chassis cluster traceoptions

user@host> show configuration chassis cluster traceoptions


file chassis size 10k files 300;
level all;

Release Information

Command introduced in Junos OS Release 12.1.

RELATED DOCUMENTATION

cluster (Chassis) | 606


traceoptions (Chassis Cluster) | 713
908

show interfaces (SRX Series)

IN THIS SECTION

Syntax | 909

Description | 910

Options | 910

Required Privilege Level | 911

Output Fields | 912

Sample Output | 925

Sample Output | 926

Sample Output | 927

Sample Output | 929

Sample Output | 932

Sample Output | 933

Sample Output | 934

Sample Output | 935

Sample Output | 935

Sample Output | 937

Sample Output | 938

Sample Output | 938

Sample Output | 940

Sample Output | 941

Sample Output | 942

Sample Output | 944

Sample Output | 946

Sample Output | 946

Sample Output | 948

Sample Output | 949

Sample Output | 951

Sample Output | 951

Sample Output | 952


909

Sample Output | 952

Sample Output | 953

Sample Output | 954

Sample Output | 956

Release Information | 956

Syntax

show interfaces {
<brief | detail | extensive | terse>
controller interface-name
descriptions interface-name
destination-class (all | destination-class-name logical-interface-name)
diagnostics optics interface-name
far-end-interval interface-fpc/pic/port
filters interface-name
flow-statistics interface-name
interval interface-name
load-balancing (detail | interface-name)
mac-database mac-address mac-address
mc-ae id identifier unit number revertive-info
media interface-name
policers interface-name
queue both-ingress-egress egress forwarding-class forwarding-class ingress l2-statistics
redundancy (detail | interface-name)
routing brief detail summary interface-name
routing-instance (all | instance-name)
snmp-index snmp-index
source-class (all | destination-class-name logical-interface-name)
statistics interface-name
switch-port switch-port number
transport pm (all | optics | otn) (all | current | currentday | interval | previousday) (all
| interface-name)
zone interface-name
}
910

Description

Display status information and statistics about interfaces on SRX Series appliance running Junos OS.

On SRX Series appliance, on configuring identical IPs on a single interface, you will not see a warning
message; instead, you will see a syslog message.

Options

• interface-name—(Optional) Display standard information about the specified interface. Following is a


list of typical interface names. Replace pim with the PIM slot and port with the port number.

• at- pim/0/port—ATM-over-ADSL or ATM-over-SHDSL interface.

• ce1-pim/0/ port—Channelized E1 interface.

• cl-0/0/8—3G wireless modem interface for SRX320 devices.

• ct1-pim/0/port—Channelized T1 interface.

• dl0—Dialer Interface for initiating ISDN and USB modem connections.

• e1-pim/0/port—E1 interface.

• e3-pim/0/port—E3 interface.

• fe-pim/0/port—Fast Ethernet interface.

• ge-pim/0/port—Gigabit Ethernet interface.

• se-pim/0/port—Serial interface.

• t1-pim/0/port—T1 (also called DS1) interface.

• t3-pim/0/port—T3 (also called DS3) interface.

• wx-slot/0/0—WAN acceleration interface, for the WXC Integrated Services Module (ISM 200).

• brief | detail | extensive | terse—(Optional) Display the specified level of output.

• controller—(Optional) Show controller information.

• descriptions—(Optional) Display interface description strings.

• destination-class—(Optional) Show statistics for destination class.


911

• diagnostics—(Optional) Show interface diagnostics information.

• far-end-interval—(Optional) Show far end interval statistics.

• filters—(Optional) Show interface filters information.

• flow-statistics—(Optional) Show security flow counters and errors.

• interval—(Optional) Show interval statistics.

• load-balancing—(Optional) Show load-balancing status.

• mac-database—(Optional) Show media access control database information.

• mc-ae—(Optional) Show MC-AE configured interface information.

• media—(Optional) Display media information.

• policers—(Optional) Show interface policers information.

• queue—(Optional) Show queue statistics for this interface.

• redundancy—(Optional) Show redundancy status.

• routing—(Optional) Show routing status.

• routing-instance—(Optional) Name of routing instance.

• snmp-index—(Optional) SNMP index of interface.

• source-class—(Optional) Show statistics for source class.

• statistics—(Optional) Display statistics and detailed output.

• switch-port—(Optional) Front end port number (0..15).

• transport—(Optional) Show interface transport information.

• zone—(Optional) Interface's zone.

Required Privilege Level

view
912

Output Fields

Table 67 on page 912 lists the output fields for the show interfaces command. Output fields are listed in
the approximate order in which they appear.

Table 67: show interfaces Output Fields

Field Name Field Description Level of Output

Physical Interface

Physical interface Name of the physical interface. All levels

Enabled State of the interface. All levels

Interface index Index number of the physical interface, which reflects its initialization detail extensive
sequence. none

SNMP ifIndex SNMP index number for the physical interface. detail extensive
none

Link-level type Encapsulation being used on the physical interface. All levels

Generation Unique number for use by Juniper Networks technical support only. detail extensive

MTU Maximum transmission unit size on the physical interface. All levels

Link mode Link mode: Full-duplex or Half-duplex.

Speed Speed at which the interface is running. All levels

BPDU error Bridge protocol data unit (BPDU) error: Detected or None

Loopback Loopback status: Enabled or Disabled. If loopback is enabled, type of All levels
loopback: Local or Remote.
913

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Source filtering Source filtering status: Enabled or Disabled. All levels

Flow control Flow control status: Enabled or Disabled. All levels

Auto-negotiation (Gigabit Ethernet interfaces) Autonegotiation status: Enabled or Disabled. All levels

Remote-fault (Gigabit Ethernet interfaces) Remote fault status: All levels

• Online—Autonegotiation is manually configured as online.

• Offline—Autonegotiation is manually configured as offline.

Device flags Information about the physical device. All levels

Interface flags Information about the interface. All levels

Link flags Information about the physical link. All levels

CoS queues Number of CoS queues configured. detail extensive


none

Current address Configured MAC address. detail extensive


none

Last flapped Date, time, and how long ago the interface went from down to up. The detail extensive
format is Last flapped: year-month-day hour:minute:second:timezone none
(hour:minute:second ago). For example, Last flapped: 2002-04-26
10:52:40 PDT (04:33:20 ago).

Input Rate Input rate in bits per second (bps) and packets per second (pps). None

Output Rate Output rate in bps and pps. None


914

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Active alarms and Ethernet-specific defects that can prevent the interface from passing detail extensive
Active defects packets. When a defect persists for a certain amount of time, it is none
promoted to an alarm. These fields can contain the value None or Link.

• None—There are no active defects or alarms.

• Link—Interface has lost its link state, which usually means that the
cable is unplugged, the far-end system has been turned off, or the
PIC is malfunctioning.

Statistics last Time when the statistics for the interface were last set to zero. detail extensive
cleared

Traffic statistics Number and rate of bytes and packets received and transmitted on the detail extensive
physical interface.

• Input bytes—Number of bytes received on the interface.

• Output bytes—Number of bytes transmitted on the interface.

• Input packets—Number of packets received on the interface.

• Output packets—Number of packets transmitted on the interface.


915

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Input errors Input errors on the interface. extensive

• Errors—Sum of the incoming frame terminates and FCS errors.

• Drops—Number of packets dropped by the input queue of the I/O


Manager ASIC. If the interface is saturated, this number increments
once for every packet that is dropped by the ASIC's RED
mechanism.

• Framing errors—Number of packets received with an invalid frame


checksum (FCS).

• Runts—Number of frames received that are smaller than the runt


threshold.

• Policed discards—Number of frames that the incoming packet match


code discarded because they were not recognized or not of interest.
Usually, this field reports protocols that Junos OS does not handle.

• L3 incompletes—Number of incoming packets discarded because


they failed Layer 3 (usually IPv4) sanity checks of the header. For
example, a frame with less than 20 bytes of available IP header is
discarded. L3 incomplete errors can be ignored by configuring the
ignore-l3-incompletes statement.

• L2 channel errors—Number of times the software did not find a valid


logical interface for an incoming frame.

• L2 mismatch timeouts—Number of malformed or short packets that


caused the incoming packet handler to discard the frame as
unreadable.

• FIFO errors—Number of FIFO errors in the receive direction that are


reported by the ASIC on the PIC. If this value is ever nonzero, the
PIC is probably malfunctioning.

• Resource errors—Sum of transmit drops.


916

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Output errors Output errors on the interface. extensive

• Carrier transitions—Number of times the interface has gone from


down to up. This number does not normally increment quickly,
increasing only when the cable is unplugged, the far-end system is
powered down and then up, or another problem occurs. If the
number of carrier transitions increments quickly (perhaps once
every 10 seconds), the cable, the far-end system, or the PIC or PIM
is malfunctioning.

• Errors—Sum of the outgoing frame terminates and FCS errors.

• Drops—Number of packets dropped by the output queue of the I/O


Manager ASIC. If the interface is saturated, this number increments
once for every packet that is dropped by the ASIC's RED
mechanism.

• Collisions—Number of Ethernet collisions. The Gigabit Ethernet PIC


supports only full-duplex operation, so for Gigabit Ethernet PICs,
this number should always remain 0. If it is nonzero, there is a
software bug.

• Aged packets—Number of packets that remained in shared packet


SDRAM so long that the system automatically purged them. The
value in this field should never increment. If it does, it is most likely a
software bug or possibly malfunctioning hardware.

• FIFO errors—Number of FIFO errors in the send direction as


reported by the ASIC on the PIC. If this value is ever nonzero, the
PIC is probably malfunctioning.

• HS link CRC errors—Number of errors on the high-speed links


between the ASICs responsible for handling the interfaces.

• MTU errors—Number of packets whose size exceeded the MTU of


the interface.

• Resource errors—Sum of transmit drops.

Ingress queues Total number of ingress queues supported on the specified interface. extensive
917

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Queue counters and CoS queue number and its associated user-configured forwarding class detail extensive
queue number name.

• Queued packets—Number of queued packets.

• Transmitted packets—Number of transmitted packets.

• Dropped packets—Number of packets dropped by the ASIC's RED


mechanism.
918

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

MAC statistics Receive and Transmit statistics reported by the PIC's MAC subsystem, extensive
including the following:

• Total octets and total packets—Total number of octets and packets.

• Unicast packets, Broadcast packets, and Multicast packets—Number


of unicast, broadcast, and multicast packets.

• CRC/Align errors—Total number of packets received that had a length


(excluding framing bits, but including FCS octets) of between 64 and
1518 octets, inclusive, and had either a bad FCS with an integral
number of octets (FCS Error) or a bad FCS with a nonintegral
number of octets (Alignment Error).

• FIFO error—Number of FIFO errors that are reported by the ASIC on


the PIC. If this value is ever nonzero, the PIC or a cable is probably
malfunctioning.

• MAC control frames—Number of MAC control frames.

• MAC pause frames—Number of MAC control frames with pause


operational code.

• Oversized frames—There are two possible conditions regarding the


number of oversized frames:

• Packet length exceeds 1518 octets, or

• Packet length exceeds MRU

• Jabber frames—Number of frames that were longer than 1518 octets


(excluding framing bits, but including FCS octets), and had either an
FCS error or an alignment error. This definition of jabber is different
from the definition in IEEE-802.3 section 8.2.1.5 (10BASE5) and
section 10.3.1.4 (10BASE2). These documents define jabber as the
condition in which any packet exceeds 20 ms. The allowed range to
detect jabber is from 20 ms to 150 ms.

• Fragment frames—Total number of packets that were less than 64


octets in length (excluding framing bits, but including FCS octets)
and had either an FCS error or an alignment error. Fragment frames
919

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

normally increment because both runts (which are normal


occurrences caused by collisions) and noise hits are counted.

• VLAN tagged frames—Number of frames that are VLAN tagged. The


system uses the TPID of 0x8100 in the frame to determine whether
a frame is tagged or not.

• Code violations—Number of times an event caused the PHY to


indicate “Data reception error” or “invalid data symbol error.”
920

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Filter statistics Receive and Transmit statistics reported by the PIC's MAC address filter extensive
subsystem. The filtering is done by the content-addressable memory
(CAM) on the PIC. The filter examines a packet's source and destination
MAC addresses to determine whether the packet should enter the
system or be rejected.

• Input packet count—Number of packets received from the MAC


hardware that the filter processed.

• Input packet rejects—Number of packets that the filter rejected


because of either the source MAC address or the destination MAC
address.

• Input DA rejects—Number of packets that the filter rejected because


the destination MAC address of the packet is not on the accept list.
It is normal for this value to increment. When it increments very
quickly and no traffic is entering the device from the far-end system,
either there is a bad ARP entry on the far-end system, or multicast
routing is not on and the far-end system is sending many multicast
packets to the local device (which the router is rejecting).

• Input SA rejects—Number of packets that the filter rejected because


the source MAC address of the packet is not on the accept list. The
value in this field should increment only if source MAC address
filtering has been enabled. If filtering is enabled, if the value
increments quickly, and if the system is not receiving traffic that it
should from the far-end system, it means that the user-configured
source MAC addresses for this interface are incorrect.

• Output packet count—Number of packets that the filter has given to


the MAC hardware.

• Output packet pad count—Number of packets the filter padded to the


minimum Ethernet size (60 bytes) before giving the packet to the
MAC hardware. Usually, padding is done only on small ARP packets,
but some very small IP packets can also require padding. If this value
increments rapidly, either the system is trying to find an ARP entry
for a far-end system that does not exist or it is misconfigured.

• Output packet error count—Number of packets with an indicated


error that the filter was given to transmit. These packets are usually
921

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

aged packets or are the result of a bandwidth problem on the FPC


hardware. On a normal system, the value of this field should not
increment.

• CAM destination filters, CAM source filters—Number of entries in


the CAM dedicated to destination and source MAC address filters.
There can only be up to 64 source entries. If source filtering is
disabled, which is the default, the values for these fields should be 0.

Autonegotiation Information about link autonegotiation. extensive


information
• Negotiation status:

• Incomplete—Ethernet interface has the speed or link mode


configured.

• No autonegotiation—Remote Ethernet interface has the speed or


link mode configured, or does not perform autonegotiation.

• Complete—Ethernet interface is connected to a device that


performs autonegotiation and the autonegotiation process is
successful.

Packet Forwarding Information about the configuration of the Packet Forwarding Engine: extensive
Engine configuration
• Destination slot—FPC slot number.
922

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

CoS information Information about the CoS queue for the physical interface. extensive

• CoS transmit queue—Queue number and its associated user-


configured forwarding class name.

• Bandwidth %—Percentage of bandwidth allocated to the queue.

• Bandwidth bps—Bandwidth allocated to the queue (in bps).

• Buffer %—Percentage of buffer space allocated to the queue.

• Buffer usec—Amount of buffer space allocated to the queue, in


microseconds. This value is nonzero only if the buffer size is
configured in terms of time.

• Priority—Queue priority: low or high.

• Limit—Displayed if rate limiting is configured for the queue. Possible


values are none and exact. If exact is configured, the queue transmits
only up to the configured bandwidth, even if excess bandwidth is
available. If none is configured, the queue transmits beyond the
configured bandwidth if bandwidth is available.

Interface transmit Status of the interface-transmit-statistics configuration: Enabled or detail extensive


statistics Disabled.

Queue counters CoS queue number and its associated user-configured forwarding class detail extensive
(Egress) name.

• Queued packets—Number of queued packets.

• Transmitted packets—Number of transmitted packets.

• Dropped packets—Number of packets dropped by the ASIC's RED


mechanism.

Logical Interface

Logical interface Name of the logical interface. All levels


923

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Index Index number of the logical interface, which reflects its initialization detail extensive
sequence. none

SNMP ifIndex SNMP interface index number for the logical interface. detail extensive
none

Generation Unique number for use by Juniper Networks technical support only. detail extensive

Flags Information about the logical interface. All levels

Encapsulation Encapsulation on the logical interface. All levels

Traffic statistics Number and rate of bytes and packets received and transmitted on the detail extensive
specified interface set.

• Input bytes, Output bytes—Number of bytes received and


transmitted on the interface set. The value in this field also includes
the Layer 2 overhead bytes for ingress or egress traffic on Ethernet
interfaces if you enable accounting of Layer 2 overhead at the PIC
level or the logical interface level.

• Input packets, Output packets—Number of packets received and


transmitted on the interface set.

Local statistics Number and rate of bytes and packets destined to the device. extensive

Transit statistics Number and rate of bytes and packets transiting the switch. extensive

NOTE: For Gigabit Ethernet intelligent queuing 2 (IQ2) interfaces, the


logical interface egress statistics might not accurately reflect the traffic
on the wire when output shaping is applied. Traffic management output
shaping might drop packets after they are tallied by the Output bytes and
Output packets interface counters. However, correct values display for
both of these egress statistics when per-unit scheduling is enabled for
the Gigabit Ethernet IQ2 physical interface, or when a single logical
interface is actively using a shared scheduler.
924

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Security Security zones that interface belongs to. extensive

Flow Input Statistics on packets received by flow module. extensive


statistics

Flow Output Statistics on packets sent by flow module. extensive


statistics

Flow error Statistics on errors in the flow module. extensive


statistics (Packets
dropped due to)

Protocol Protocol family. detail extensive


none

MTU Maximum transmission unit size on the logical interface. detail extensive
none

Generation Unique number for use by Juniper Networks technical support only. detail extensive

Route Table Route table in which the logical interface address is located. For detail extensive
example, 0 refers to the routing table inet.0. none

Flags Information about protocol family flags. . detail extensive

Addresses, Flags Information about the address flags.. detail extensive


none

Destination IP address of the remote side of the connection. detail extensive


none
925

Table 67: show interfaces Output Fields (Continued)

Field Name Field Description Level of Output

Local IP address of the logical interface. detail extensive


none

Broadcast Broadcast address of the logical interface. detail extensive


none

Generation Unique number for use by Juniper Networks technical support only. detail extensive

Sample Output

show interfaces Gigabit Ethernet

user@host> show interfaces ge-0/0/1


Physical interface: ge-0/0/1, Enabled, Physical link is Down
Interface index: 135, SNMP ifIndex: 510
Link-level type: Ethernet, MTU: 1514, Link-mode: Full-duplex, Speed: 1000mbps,
BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled,
Source filtering: Disabled, Flow control: Enabled, Auto-negotiation: Enabled,
Remote fault: Online
Device flags : Present Running Down
Interface flags: Hardware-Down SNMP-Traps Internal: 0x0
Link flags : None
CoS queues : 8 supported, 8 maximum usable queues
Current address: 00:00:12:e4:b1:01, Hardware address: 00:00:12:e4:b1:01
Last flapped : 2015-05-12 08:36:59 UTC (1w1d 22:42 ago)
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Active alarms : LINK
Active defects : LINK
Interface transmit statistics: Disabled

Logical interface ge-0/0/1.0 (Index 71) (SNMP ifIndex 514)


Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
926

Input packets : 0
Output packets: 0
Security: Zone: public
Protocol inet, MTU: 1500
Flags: Sendbcast-pkt-to-re
Addresses, Flags: Dest-route-down Is-Preferred Is-Primary
Destination: 10.1.1/24, Local: 10.1.1.1, Broadcast: 10.1.1.255

Sample Output

show interfaces brief (Gigabit Ethernet)

user@host> show interfaces ge-3/0/2 brief


Physical interface: ge-3/0/2, Enabled, Physical link is Up
Link-level type: 52, MTU: 1522, Speed: 1000mbps, Loopback: Disabled,
Source filtering: Disabled, Flow control: Enabled, Auto-negotiation: Enabled,
Remote fault: Online
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x4000
Link flags : None

Logical interface ge-3/0/2.0


Flags: SNMP-Traps 0x4000
VLAN-Tag [ 0x8100.512 0x8100.513 ] In(pop-swap 0x8100.530) Out(swap-push 0x8100.512
0x8100.513)
Encapsulation: VLAN-CCC
ccc

Logical interface ge-3/0/2.32767


Flags: SNMP-Traps 0x4000 VLAN-Tag [ 0x0000.0 ] Encapsulation: ENET2
927

Sample Output

show interfaces detail (Gigabit Ethernet)

user@host> show interfaces ge-0/0/1 detail


Physical interface: ge-0/0/1, Enabled, Physical link is Down
Interface index: 135, SNMP ifIndex: 510, Generation: 138
Link-level type: Ethernet, MTU: 1514, Link-mode: Full-duplex, Speed: 1000mbps, BPDU Error:
None, MAC-REWRITE Error: None, Loopback: Disabled, Source filtering: Disabled,
Flow control: Enabled, Auto-negotiation: Enabled, Remote fault: Online
Device flags : Present Running Down
Interface flags: Hardware-Down SNMP-Traps Internal: 0x0
Link flags : None
CoS queues : 8 supported, 8 maximum usable queues
Hold-times : Up 0 ms, Down 0 ms
Current address: 00:1f:12:e4:b1:01, Hardware address: 00:1f:12:e4:b1:01
Last flapped : 2015-05-12 08:36:59 UTC (1w2d 00:00 ago)
Statistics last cleared: Never
Traffic statistics:
Input bytes : 0 0 bps
Output bytes : 0 0 bps
Input packets: 0 0 pps
Output packets: 0 0 pps
Egress queues: 8 supported, 4 in use
Queue counters: Queued packets Transmitted packets Dropped packets
0 best-effort 0 0 0
1 expedited-fo 0 0 0
2 assured-forw 0 0 0
3 network-cont 0 0 0
Queue number: Mapped forwarding classes
0 best-effort
1 expedited-forwarding
2 assured-forwarding
3 network-control
Active alarms : LINK
Active defects : LINK
Interface transmit statistics: Disabled

Logical interface ge-0/0/1.0 (Index 71) (SNMP ifIndex 514) (Generation 136)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Traffic statistics:
928

Input bytes : 0
Output bytes : 0
Input packets: 0
Output packets: 0
Local statistics:
Input bytes : 0
Output bytes : 0
Input packets: 0
Output packets: 0
Transit statistics:
Input bytes : 0 0 bps
Output bytes : 0 0 bps
Input packets: 0 0 pps
Output packets: 0 0 pps
Security: Zone: public
Flow Statistics :
Flow Input statistics :
Self packets : 0
ICMP packets : 0
VPN packets : 0
Multicast packets : 0
Bytes permitted by policy : 0
Connections established : 0
Flow Output statistics:
Multicast packets : 0
Bytes permitted by policy : 0
Flow error statistics (Packets dropped due to):
Address spoofing: 0
Authentication failed: 0
Incoming NAT errors: 0
Invalid zone received packet: 0
Multiple user authentications: 0
Multiple incoming NAT: 0
No parent for a gate: 0
No one interested in self packets: 0
No minor session: 0
No more sessions: 0
No NAT gate: 0
No route present: 0
No SA for incoming SPI: 0
No tunnel found: 0
No session for a gate: 0
No zone or NULL zone binding 0
929

Policy denied: 0
Security association not active: 0
TCP sequence number out of window: 0
Syn-attack protection: 0
User authentication errors: 0
Protocol inet, MTU: 1500, Generation: 150, Route table: 0
Flags: Sendbcast-pkt-to-re
Addresses, Flags: Dest-route-down Is-Preferred Is-Primary
Destination: 10.1.1/24, Local: 10.1.1.1, Broadcast: 10.1.1.255, Generation: 150

Sample Output

show interfaces extensive (Gigabit Ethernet)

user@host> show interfaces ge-0/0/1.0 extensive


Physical interface: ge-0/0/1, Enabled, Physical link is Down
Interface index: 135, SNMP ifIndex: 510, Generation: 138
Link-level type: Ethernet, MTU: 1514, Link-mode: Full-duplex, Speed: 1000mbps,
BPDU Error: None, MAC-REWRITE Error: None, Loopback: Disabled,
Source filtering: Disabled, Flow control: Enabled, Auto-negotiation: Enabled,
Remote fault: Online
Device flags : Present Running Down
Interface flags: Hardware-Down SNMP-Traps Internal: 0x0
Link flags : None
CoS queues : 8 supported, 8 maximum usable queues
Hold-times : Up 0 ms, Down 0 ms
Current address: 00:1f:12:e4:b1:01, Hardware address: 00:1f:12:e4:b1:01
Last flapped : 2015-05-12 08:36:59 UTC (1w1d 22:57 ago)
Statistics last cleared: Never
Traffic statistics:
Input bytes : 0 0 bps
Output bytes : 0 0 bps
Input packets: 0 0 pps
Output packets: 0 0 pps
Input errors:
Errors: 0, Drops: 0, Framing errors: 0, Runts: 0, Policed discards: 0,
L3 incompletes: 0, L2 channel errors: 0, L2 mismatch timeouts: 0,
FIFO errors: 0, Resource errors: 0
Output errors:
930

Carrier transitions: 0, Errors: 0, Drops: 0, Collisions: 0, Aged packets: 0,


FIFO errors: 0, HS link CRC errors: 0, MTU errors: 0, Resource errors: 0
Egress queues: 8 supported, 4 in use
Queue counters: Queued packets Transmitted packets Dropped packets
0 best-effort 0 0 0
1 expedited-fo 0 0 0
2 assured-forw 0 0 0
3 network-cont 0 0 0
Queue number: Mapped forwarding classes
0 best-effort
1 expedited-forwarding
2 assured-forwarding
3 network-control
Active alarms : LINK
Active defects : LINK
MAC statistics: Receive Transmit
Total octets 0 0
Total packets 0 0
Unicast packets 0 0
Broadcast packets 0 0
Multicast packets 0 0
CRC/Align errors 0 0
FIFO errors 0 0
MAC control frames 0 0
MAC pause frames 0 0
Oversized frames 0
Jabber frames 0
Fragment frames 0
VLAN tagged frames 0
Code violations 0
Filter statistics:
Input packet count 0
Input packet rejects 0
Input DA rejects 0
Input SA rejects 0
Output packet count 0
Output packet pad count 0
Output packet error count 0
CAM destination filters: 2, CAM source filters: 0
Autonegotiation information:
Negotiation status: Incomplete
Packet Forwarding Engine configuration:
Destination slot: 0
931

CoS information:
Direction : Output
CoS transmit queue Bandwidth Buffer Priority Limit
% bps % usec
0 best-effort 95 950000000 95 0 low none
3 network-control 5 50000000 5 0 low none
Interface transmit statistics: Disabled

Logical interface ge-0/0/1.0 (Index 71) (SNMP ifIndex 514) (Generation 136)
Flags: Device-Down SNMP-Traps 0x0 Encapsulation: ENET2
Traffic statistics:
Input bytes : 0
Output bytes : 0
Input packets: 0
Output packets: 0
Local statistics:
Input bytes : 0
Output bytes : 0
Input packets: 0
Output packets: 0
Transit statistics:
Input bytes : 0 0 bps
Output bytes : 0 0 bps
Input packets: 0 0 pps
Output packets: 0 0 pps
Security: Zone: public
Flow Statistics :
Flow Input statistics :
Self packets : 0
ICMP packets : 0
VPN packets : 0
Multicast packets : 0
Bytes permitted by policy : 0
Connections established : 0
Flow Output statistics:
Multicast packets : 0
Bytes permitted by policy : 0
Flow error statistics (Packets dropped due to):
Address spoofing: 0
Authentication failed: 0
Incoming NAT errors: 0
Invalid zone received packet: 0
Multiple user authentications: 0
932

Multiple incoming NAT: 0


No parent for a gate: 0
No one interested in self packets: 0
No minor session: 0
No more sessions: 0
No NAT gate: 0
No route present: 0
No SA for incoming SPI: 0
No tunnel found: 0
No session for a gate: 0
No zone or NULL zone binding 0
Policy denied: 0
Security association not active: 0
TCP sequence number out of window: 0
Syn-attack protection: 0
User authentication errors: 0
Protocol inet, MTU: 1500, Generation: 150, Route table: 0
Flags: Sendbcast-pkt-to-re
Addresses, Flags: Dest-route-down Is-Preferred Is-Primary
Destination: 10.1.1/24, Local: 10.1.1.1, Broadcast: 10.1.1.255,
Generation: 150

Sample Output

show interfaces terse

user@host> show interfaces terse


Interface Admin Link Proto Local Remote
ge-0/0/0 up up
ge-0/0/0.0 up up inet 10.209.4.61/18
gr-0/0/0 up up
ip-0/0/0 up up
st0 up up
st0.1 up ready inet
ls-0/0/0 up up
lt-0/0/0 up up
mt-0/0/0 up up
933

pd-0/0/0 up up
pe-0/0/0 up up
e3-1/0/0 up up
t3-2/0/0 up up
e1-3/0/0 up up
se-4/0/0 up down
t1-5/0/0 up up
br-6/0/0 up up
dc-6/0/0 up up
dc-6/0/0.32767 up up
bc-6/0/0:1 down up
bc-6/0/0:1.0 up down
dl0 up up
dl0.0 up up inet
dsc up up
gre up up
ipip up up
lo0 up up
lo0.16385 up up inet 10.0.0.1 --> 0/0
10.0.0.16 --> 0/0
lsi up up
mtun up up
pimd up up
pime up up
pp0 up up

Sample Output

show interfaces controller (Channelized E1 IQ with Logical E1)

user@host> show interfaces controller ce1-1/2/6

Controller Admin Link


ce1-1/2/6 up up
e1-1/2/6 up up
934

show interfaces controller (Channelized E1 IQ with Logical DS0)

user@host> show interfaces controller ce1-1/2/3

Controller Admin Link


ce1-1/2/3 up up
ds-1/2/3:1 up up
ds-1/2/3:2 up up

Sample Output

show interfaces descriptions

user@host> show interfaces descriptions


Interface Admin Link Description
so-1/0/0 up up M20-3#1
so-2/0/0 up up GSR-12#1
ge-3/0/0 up up SMB-OSPF_Area300
so-3/3/0 up up GSR-13#1
so-3/3/1 up up GSR-13#2
ge-4/0/0 up up T320-7#1
ge-5/0/0 up up T320-7#2
so-7/1/0 up up M160-6#1
ge-8/0/0 up up T320-7#3
ge-9/0/0 up up T320-7#4
so-10/0/0 up up M160-6#2
so-13/0/0 up up M20-3#2
so-14/0/0 up up GSR-12#2
ge-15/0/0 up up SMB-OSPF_Area100
ge-15/0/1 up up GSR-13#3
935

Sample Output

show interfaces destination-class all

user@host> show interfaces destination-class all


Logical interface so-4/0/0.0
Packets Bytes
Destination class (packet-per-second) (bits-per-second)
gold 0 0
( 0) ( 0)
silver 0 0
( 0) ( 0)
Logical interface so-0/1/3.0
Packets Bytes
Destination class (packet-per-second) (bits-per-second)
gold 0 0
( 0) ( 0)
silver 0 0
( 0) ( 0)

Sample Output

show interfaces diagnostics optics

user@host> show interfaces diagnostics optics ge-2/0/0


Physical interface: ge-2/0/0
Laser bias current : 7.408 mA
Laser output power : 0.3500 mW / -4.56 dBm
Module temperature : 23 degrees C / 73 degrees F
Module voltage : 3.3450 V
Receiver signal average optical power : 0.0002 mW / -36.99 dBm
Laser bias current high alarm : Off
Laser bias current low alarm : Off
Laser bias current high warning : Off
Laser bias current low warning : Off
Laser output power high alarm : Off
Laser output power low alarm : Off
Laser output power high warning : Off
936

Laser output power low warning : Off


Module temperature high alarm : Off
Module temperature low alarm : Off
Module temperature high warning : Off
Module temperature low warning : Off
Module voltage high alarm : Off
Module voltage low alarm : Off
Module voltage high warning : Off
Module voltage low warning : Off
Laser rx power high alarm : Off
Laser rx power low alarm : On
Laser rx power high warning : Off
Laser rx power low warning : On
Laser bias current high alarm threshold : 17.000 mA
Laser bias current low alarm threshold : 1.000 mA
Laser bias current high warning threshold : 14.000 mA
Laser bias current low warning threshold : 2.000 mA
Laser output power high alarm threshold : 0.6310 mW / -2.00 dBm
Laser output power low alarm threshold : 0.0670 mW / -11.74 dBm
Laser output power high warning threshold : 0.6310 mW / -2.00 dBm
Laser output power low warning threshold : 0.0790 mW / -11.02 dBm
Module temperature high alarm threshold : 95 degrees C / 203 degrees F
Module temperature low alarm threshold : -25 degrees C / -13 degrees F
Module temperature high warning threshold : 90 degrees C / 194 degrees F
Module temperature low warning threshold : -20 degrees C / -4 degrees F
Module voltage high alarm threshold : 3.900 V
Module voltage low alarm threshold : 2.700 V
Module voltage high warning threshold : 3.700 V
Module voltage low warning threshold : 2.900 V
Laser rx power high alarm threshold : 1.2590 mW / 1.00 dBm
Laser rx power low alarm threshold : 0.0100 mW / -20.00 dBm
Laser rx power high warning threshold : 0.7940 mW / -1.00 dBm
Laser rx power low warning threshold : 0.0158 mW / -18.01 dBm
937

Sample Output

show interfaces far-end-interval coc12-5/2/0

user@host> show interfaces far-end-interval coc12-5/2/0


Physical interface: coc12-5/2/0, SNMP ifIndex: 121
05:30-current:
ES-L: 1, SES-L: 1, UAS-L: 0
05:15-05:30:
ES-L: 0, SES-L: 0, UAS-L: 0
05:00-05:15:
ES-L: 0, SES-L: 0, UAS-L: 0
04:45-05:00:
ES-L: 0, SES-L: 0, UAS-L: 0
04:30-04:45:
ES-L: 0, SES-L: 0, UAS-L: 0
04:15-04:30:
ES-L: 0, SES-L: 0, UAS-L: 0
04:00-04:15:
...

show interfaces far-end-interval coc1-5/2/1:1

user@host> run show interfaces far-end-interval coc1-5/2/1:1


Physical interface: coc1-5/2/1:1, SNMP ifIndex: 342
05:30-current:
ES-L: 1, SES-L: 1, UAS-L: 0, ES-P: 0, SES-P: 0, UAS-P: 0
05:15-05:30:
ES-L: 0, SES-L: 0, UAS-L: 0, ES-P: 0, SES-P: 0, UAS-P: 0
05:00-05:15:
ES-L: 0, SES-L: 0, UAS-L: 0, ES-P: 0, SES-P: 0, UAS-P: 0
04:45-05:00:
ES-L: 0, SES-L: 0, UAS-L: 0, ES-P: 0, SES-P: 0, UAS-P: 0
04:30-04:45:
ES-L: 0, SES-L: 0, UAS-L: 0, ES-P: 0, SES-P: 0, UAS-P: 0
04:15-04:30:
ES-L: 0, SES-L: 0, UAS-L: 0, ES-P: 0, SES-P: 0, UAS-P: 0
04:00-04:15:
938

Sample Output

show interfaces filters

user@host> show interfaces filters


Interface Admin Link Proto Input Filter Output Filter
ge-0/0/0 up up
ge-0/0/0.0 up up inet
iso
ge-5/0/0 up up
ge-5/0/0.0 up up any f-any
inet f-inet
multiservice
gr-0/3/0 up up
ip-0/3/0 up up
mt-0/3/0 up up
pd-0/3/0 up up
pe-0/3/0 up up
vt-0/3/0 up up
at-1/0/0 up up
at-1/0/0.0 up up inet
iso
at-1/1/0 up down
at-1/1/0.0 up down inet
iso
....

Sample Output

show interfaces flow-statistics (Gigabit Ethernet)

user@host> show interfaces flow-statistics ge-0/0/1.0


Logical interface ge-0/0/1.0 (Index 70) (SNMP ifIndex 49)
Flags: SNMP-Traps Encapsulation: ENET2
Input packets : 5161
Output packets: 83
Security: Zone: zone2
Allowed host-inbound traffic : bootp bfd bgp dns dvmrp ldp msdp nhrp ospf pgm
939

pim rip router-discovery rsvp sap vrrp dhcp finger ftp tftp ident-reset http https ike
netconf ping rlogin rpm rsh snmp snmp-trap ssh telnet traceroute xnm-clear-text xnm-ssl
lsping
Flow Statistics :
Flow Input statistics :
Self packets : 0
ICMP packets : 0
VPN packets : 2564
Bytes permitted by policy : 3478
Connections established : 1
Flow Output statistics:
Multicast packets : 0
Bytes permitted by policy : 16994
Flow error statistics (Packets dropped due to):
Address spoofing: 0
Authentication failed: 0
Incoming NAT errors: 0
Invalid zone received packet: 0
Multiple user authentications: 0
Multiple incoming NAT: 0
No parent for a gate: 0
No one interested in self packets: 0
No minor session: 0
No more sessions: 0
No NAT gate: 0
No route present: 0
No SA for incoming SPI: 0
No tunnel found: 0
No session for a gate: 0
No zone or NULL zone binding 0
Policy denied: 0
Security association not active: 0
TCP sequence number out of window: 0
Syn-attack protection: 0
User authentication errors: 0
Protocol inet, MTU: 1500
Flags: None
Addresses, Flags: Is-Preferred Is-Primary
Destination: 203.0.113.1/24, Local: 203.0.113.2, Broadcast: 203.0.113.255
940

Sample Output

show interfaces interval (Channelized OC12)

user@host> show interfaces interval t3-0/3/0:0


Physical interface: t3-0/3/0:0, SNMP ifIndex: 23
17:43-current:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
SEFS: 0, UAS: 0
17:28-17:43:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
SEFS: 0, UAS: 0
17:13-17:28:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
SEFS: 0, UAS: 0
16:58-17:13:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
SEFS: 0, UAS: 0
16:43-16:58:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
...
Interval Total:
LCV: 230, PCV: 1145859, CCV: 455470, LES: 0, PES: 230, PSES: 230,
CES: 230, CSES: 230, SEFS: 230, UAS: 238

show interfaces interval (E3)

user@host> show interfaces interval e3-0/3/0


Physical interface: e3-0/3/0, SNMP ifIndex: 23
17:43-current:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
SEFS: 0, UAS: 0
17:28-17:43:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
SEFS: 0, UAS: 0
17:13-17:28:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
SEFS: 0, UAS: 0
16:58-17:13:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
941

SEFS: 0, UAS: 0
16:43-16:58:
LCV: 0, PCV: 0, CCV: 0, LES: 0, PES: 0, PSES: 0, CES: 0, CSES: 0,
....
Interval Total:
LCV: 230, PCV: 1145859, CCV: 455470, LES: 0, PES: 230, PSES: 230,
CES: 230, CSES: 230, SEFS: 230, UAS: 238

show interfaces interval (SONET/SDH)

user@host> show interfaces interval so-0/1/0


Physical interface: so-0/1/0, SNMP ifIndex: 19
20:02-current:
ES-S: 0, SES-S: 0, SEFS-S: 0, ES-L: 0, SES-L: 0, UAS-L: 0, ES-P: 0,
SES-P: 0, UAS-P: 0
19:47-20:02:
ES-S: 267, SES-S: 267, SEFS-S: 267, ES-L: 267, SES-L: 267, UAS-L: 267,
ES-P: 267, SES-P: 267, UAS-P: 267
19:32-19:47:
ES-S: 56, SES-S: 56, SEFS-S: 56, ES-L: 56, SES-L: 56, UAS-L: 46, ES-P: 56, SES-P: 56,
UAS-P: 46
19:17-19:32:
ES-S: 0, SES-S: 0, SEFS-S: 0, ES-L: 0, SES-L: 0, UAS-L: 0, ES-P: 0,
SES-P: 0, UAS-P: 0
19:02-19:17:
.....

Sample Output

show interfaces load-balancing

user@host> show interfaces load-balancing


Interface State Last change Member count
ams0 Up 1d 00:50 2
ams1 Up 00:00:59 2
942

show interfaces load-balancing detail

user@host>show interfaces load-balancing detail


Load-balancing interfaces detail
Interface : ams0
State : Up
Last change : 1d 00:51
Member count : 2
Members :
Interface Weight State
mams-2/0/0 10 Active
mams-2/1/0 10 Active

Sample Output

show interfaces mac-database (All MAC Addresses on a Port)

user@host> show interfaces mac-database xe-0/3/3


Physical interface: xe-0/3/3, Enabled, Physical link is Up
Interface index: 372, SNMP ifIndex: 788
Link-level type: Ethernet, MTU: 1514, LAN-PHY mode, Speed: 10Gbps, Loopback: None, Source
filtering: Disabled, Flow control: Enabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x4000
Link flags : None

Logical interface xe-0/3/3.0 (Index 364) (SNMP ifIndex 829)


Flags: SNMP-Traps 0x4004000 Encapsulation: ENET2
MAC address Input frames Input bytes Output frames Output bytes
00:00:00:00:00:00 1 56 0 0
00:00:c0:01:01:02 7023810 323095260 0 0
00:00:c0:01:01:03 7023810 323095260 0 0
00:00:c0:01:01:04 7023810 323095260 0 0
00:00:c0:01:01:05 7023810 323095260 0 0
00:00:c0:01:01:06 7023810 323095260 0 0
00:00:c0:01:01:07 7023810 323095260 0 0
943

00:00:c0:01:01:08 7023809 323095214 0 0


00:00:c0:01:01:09 7023809 323095214 0 0
00:00:c0:01:01:0a 7023809 323095214 0 0
00:00:c0:01:01:0b 7023809 323095214 0 0
00:00:c8:01:01:02 30424784 1399540064 37448598 1722635508
00:00:c8:01:01:03 30424784 1399540064 37448598 1722635508
00:00:c8:01:01:04 30424716 1399536936 37448523 1722632058
00:00:c8:01:01:05 30424789 1399540294 37448598 1722635508
00:00:c8:01:01:06 30424788 1399540248 37448597 1722635462
00:00:c8:01:01:07 30424783 1399540018 37448597 1722635462
00:00:c8:01:01:08 30424783 1399540018 37448596 1722635416
00:00:c8:01:01:09 8836796 406492616 8836795 406492570
00:00:c8:01:01:0a 30424712 1399536752 37448521 1722631966
00:00:c8:01:01:0b 30424715 1399536890 37448523 1722632058
Number of MAC addresses : 21

show interfaces mac-database (All MAC Addresses on a Service)

user@host> show interfaces mac-database xe-0/3/3


Logical interface xe-0/3/3.0 (Index 364) (SNMP ifIndex 829)
Flags: SNMP-Traps 0x4004000 Encapsulation: ENET2
MAC address Input frames Input bytes Output frames Output bytes
00:00:00:00:00:00 1 56 0 0
00:00:c0:01:01:02 7023810 323095260 0 0
00:00:c0:01:01:03 7023810 323095260 0 0
00:00:c0:01:01:04 7023810 323095260 0 0
00:00:c0:01:01:05 7023810 323095260 0 0
00:00:c0:01:01:06 7023810 323095260 0 0
00:00:c0:01:01:07 7023810 323095260 0 0
00:00:c0:01:01:08 7023809 323095214 0 0
00:00:c0:01:01:09 7023809 323095214 0 0
00:00:c0:01:01:0a 7023809 323095214 0 0
00:00:c0:01:01:0b 7023809 323095214 0 0
00:00:c8:01:01:02 31016568 1426762128 38040381 1749857526
00:00:c8:01:01:03 31016568 1426762128 38040382 1749857572
00:00:c8:01:01:04 31016499 1426758954 38040306 1749854076
00:00:c8:01:01:05 31016573 1426762358 38040381 1749857526
00:00:c8:01:01:06 31016573 1426762358 38040381 1749857526
00:00:c8:01:01:07 31016567 1426762082 38040380 1749857480
00:00:c8:01:01:08 31016567 1426762082 38040379 1749857434
944

00:00:c8:01:01:09 9428580 433714680 9428580 433714680


00:00:c8:01:01:0a 31016496 1426758816 38040304 1749853984
00:00:c8:01:01:0b 31016498 1426758908 38040307 1749854122

show interfaces mac-database mac-address

user@host> show interfaces mac-database xe-0/3/3 mac-address 00:00:c8:01:01:09


Physical interface: xe-0/3/3, Enabled, Physical link is Up
Interface index: 372, SNMP ifIndex: 788
Link-level type: Ethernet, MTU: 1514, LAN-PHY mode, Speed: 10Gbps, Loopback: None, Source
filtering: Disabled, Flow control: Enabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x4000
Link flags : None

Logical interface xe-0/3/3.0 (Index 364) (SNMP ifIndex 829)


Flags: SNMP-Traps 0x4004000 Encapsulation: ENET2
MAC address: 00:00:c8:01:01:09, Type: Configured,
Input bytes : 202324652
Output bytes : 202324560
Input frames : 4398362
Output frames : 4398360
Policer statistics:
Policer type Discarded frames Discarded bytes
Output aggregate 3992386 183649756

Sample Output

show interfaces mc-ae

user@host> show interfaces mc-ae ae0 unit 512


Member Links : ae0
Local Status : active
Peer Status : active
Logical Interface : ae0.512
945

Core Facing Interface : Label Ethernet Interface


ICL-PL : Label Ethernet Interface

show interfaces media (SONET/SDH)

The following example displays the output fields unique to the show interfaces media command for a
SONET interface (with no level of output specified):

user@host> show interfaces media so-4/1/2


Physical interface: so-4/1/2, Enabled, Physical link is Up
Interface index: 168, SNMP ifIndex: 495
Link-level type: PPP, MTU: 4474, Clocking: Internal, SONET mode, Speed: OC48, Loopback:
None, FCS: 16, Payload scrambler: Enabled
Device flags : Present Running
Interface flags: Point-To-Point SNMP-Traps 16384
Link flags : Keepalives
Keepalive settings: Interval 10 seconds, Up-count 1, Down-count 3
Keepalive: Input: 1783 (00:00:00 ago), Output: 1786 (00:00:08 ago)
LCP state: Opened
NCP state: inet: Not-configured, inet6: Not-configured, iso: Not-configured, mpls: Not-
configured
CHAP state: Not-configured
CoS queues : 8 supported
Last flapped : 2005-06-15 12:14:59 PDT (04:31:29 ago)
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
SONET alarms : None
SONET defects : None
SONET errors:
BIP-B1: 121, BIP-B2: 916, REI-L: 0, BIP-B3: 137, REI-P: 16747, BIP-BIP2: 0
Received path trace: routerb so-1/1/2
Transmitted path trace: routera so-4/1/2
946

Sample Output

show interfaces policers

user@host> show interfaces policers


Interface Admin Link Proto Input Policer Output Policer
ge-0/0/0 up up
ge-0/0/0.0 up up inet
iso
gr-0/3/0 up up
ip-0/3/0 up up
mt-0/3/0 up up
pd-0/3/0 up up
pe-0/3/0 up up
...
so-2/0/0 up up
so-2/0/0.0 up up inet so-2/0/0.0-in-policer so-2/0/0.0-out-policer
iso
so-2/1/0 up down
...

show interfaces policers interface-name

user@host> show interfaces policers so-2/1/0


Interface Admin Link Proto Input Policer Output Policer
so-2/1/0 up down
so-2/1/0.0 up down inet so-2/1/0.0-in-policer so-2/1/0.0-out-policer
iso
inet6

Sample Output

show interfaces queue


947

The following truncated example shows the CoS queue sizes for queues 0, 1, and 3. Queue 1 has a
queue buffer size (guaranteed allocated memory) of 9192 bytes.

user@host> show interfaces queue


Physical interface: ge-0/0/0, Enabled, Physical link is Up
Interface index: 134, SNMP ifIndex: 509
Forwarding classes: 8 supported, 8 in use
Egress queues: 8 supported, 8 in use
Queue: 0, Forwarding classes: class0
Queued:
Packets : 0 0 pps
Bytes : 0 0 bps
Transmitted:
Packets : 0 0 pps
Bytes : 0 0 bps
Tail-dropped packets : 0 0 pps
RL-dropped packets : 0 0 pps
RL-dropped bytes : 0 0 bps
RED-dropped packets : 0 0 pps
Low : 0 0 pps
Medium-low : 0 0 pps
Medium-high : 0 0 pps
High : 0 0 pps
RED-dropped bytes : 0 0 bps
Low : 0 0 bps
Medium-low : 0 0 bps
Medium-high : 0 0 bps
High : 0 0 bps
Queue Buffer Usage:
Reserved buffer : 118750000 bytes
Queue-depth bytes :
Current : 0
..
..
Queue: 1, Forwarding classes: class1
..
..
Queue Buffer Usage:
Reserved buffer : 9192 bytes
Queue-depth bytes :
Current : 0
..
948

..
Queue: 3, Forwarding classes: class3
Queued:
..
..
Queue Buffer Usage:
Reserved buffer : 6250000 bytes
Queue-depth bytes :
Current : 0
..
..

Sample Output

show interfaces redundancy

user@host> show interfaces redundancy


Interface State Last change Primary Secondary Current status
rsp0 Not present sp-1/0/0 sp-0/2/0 both down
rsp1 On secondary 1d 23:56 sp-1/2/0 sp-0/3/0 primary down
rsp2 On primary 10:10:27 sp-1/3/0 sp-0/2/0 secondary down
rlsq0 On primary 00:06:24 lsq-0/3/0 lsq-1/0/0 both up

show interfaces redundancy (Aggregated Ethernet)

user@host> show interfaces redundancy


Interface State Last change Primary Secondary Current status
rlsq0 On secondary 00:56:12 lsq-4/0/0 lsq-3/0/0 both up
ae0
ae1
ae2
ae3
ae4
949

show interfaces redundancy detail

user@host> show interfaces redundancy detail


Interface : rlsq0
State : On primary
Last change : 00:45:47
Primary : lsq-0/2/0
Secondary : lsq-1/2/0
Current status : both up
Mode : hot-standby

Interface : rlsq0:0
State : On primary
Last change : 00:45:46
Primary : lsq-0/2/0:0
Secondary : lsq-1/2/0:0
Current status : both up
Mode : warm-standby

Sample Output

show interfaces routing brief

user@host> show interfaces routing brief


Interface State Addresses
so-5/0/3.0 Down ISO enabled
so-5/0/2.0 Up MPLS enabled
ISO enabled
INET 192.168.2.120
INET enabled
so-5/0/1.0 Up MPLS enabled
ISO enabled
INET 192.168.2.130
INET enabled
at-1/0/0.3 Up CCC enabled
at-1/0/0.2 Up CCC enabled
at-1/0/0.0 Up ISO enabled
INET 192.168.90.10
950

INET enabled
lo0.0 Up ISO 47.0005.80ff.f800.0000.0108.0001.1921.6800.5061.00
ISO enabled
INET 127.0.0.1
fxp1.0 Up
fxp0.0 Up INET 192.168.6.90

show interfaces routing detail

user@host> show interfaces routing detail


so-5/0/3.0
Index: 15, Refcount: 2, State: Up <Broadcast PointToPoint Multicast> Change:<>
Metric: 0, Up/down transitions: 0, Full-duplex
Link layer: HDLC serial line Encapsulation: PPP Bandwidth: 155Mbps
ISO address (null)
State: <Broadcast PointToPoint Multicast> Change: <>
Preference: 0 (120 down), Metric: 0, MTU: 4470 bytes
so-5/0/2.0
Index: 14, Refcount: 7, State: <Up Broadcast PointToPoint Multicast> Change:<>
Metric: 0, Up/down transitions: 0, Full-duplex
Link layer: HDLC serial line Encapsulation: PPP Bandwidth: 155Mbps
MPLS address (null)
State: <Up Broadcast PointToPoint Multicast> Change: <>
Preference: 0 (120 down), Metric: 0, MTU: 4458 bytes
ISO address (null)
State: <Up Broadcast PointToPoint Multicast> Change: <>
Preference: 0 (120 down), Metric: 0, MTU: 4470 bytes
INET address 192.168.2.120
State: <Up Broadcast PointToPoint Multicast Localup> Change: <>
Preference: 0 (120 down), Metric: 0, MTU: 4470 bytes
Local address: 192.168.2.120
Destination: 192.168.2.110/32
INET address (null)
State: <Up Broadcast PointToPoint Multicast> Change: <>
Preference: 0 (120 down), Metric: 0, MTU: 4470 bytes
...
951

Sample Output

show interfaces routing-instance all

user@host> show interfaces terse routing-instance all


Interface Admin Link Proto Local Remote Instance
at-0/0/1 up up inet 10.0.0.1/24
ge-0/0/0.0 up up inet 192.168.4.28/24 sample-a
at-0/1/0.0 up up inet6 fe80::a:0:0:4/64 sample-b
so-0/0/0.0 up up inet 10.0.0.1/32

Sample Output

show interfaces snmp-index

user@host> show interfaces snmp-index 33


Physical interface: so-2/1/1, Enabled, Physical link is Down
Interface index: 149, SNMP ifIndex: 33
Link-level type: PPP, MTU: 4474, Clocking: Internal, SONET mode, Speed: OC48, Loopback:
None, FCS: 16, Payload scrambler: Enabled
Device flags : Present Running Down
Interface flags: Hardware-Down Point-To-Point SNMP-Traps 16384
Link flags : Keepalives
CoS queues : 8 supported
Last flapped : 2005-06-15 11:45:57 PDT (05:38:43 ago)
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
SONET alarms : LOL, PLL, LOS
SONET defects : LOL, PLL, LOF, LOS, SEF, AIS-L, AIS-P
952

Sample Output

show interfaces source-class all

user@host> show interfaces source-class all


Logical interface so-0/1/0.0
Packets Bytes
Source class (packet-per-second) (bits-per-second)
gold 1928095 161959980
( 889) ( 597762)
bronze 0 0
( 0) ( 0)
silver 0 0
( 0) ( 0)
Logical interface so-0/1/3.0
Packets Bytes
Source class (packet-per-second) (bits-per-second)
gold 0 0
( 0) ( 0)
bronze 0 0
( 0) ( 0)
silver 116113 9753492
( 939) ( 631616)

Sample Output

show interfaces statistics (Fast Ethernet)

user@host> show interfaces fe-1/3/1 statistics


Physical interface: fe-1/3/1, Enabled, Physical link is Up
Interface index: 144, SNMP ifIndex: 1042
Description: ford fe-1/3/1
Link-level type: Ethernet, MTU: 1514, Speed: 100mbps, Loopback: Disabled,
Source filtering: Disabled, Flow control: Enabled
Device flags : Present Running
Interface flags: SNMP-Traps Internal: 0x4000
CoS queues : 4 supported, 4 maximum usable queues
Current address: 00:90:69:93:04:dc, Hardware address: 00:90:69:93:04:dc
953

Last flapped : 2006-04-18 03:08:59 PDT (00:01:24 ago)


Statistics last cleared: Never
Input rate : 0 bps (0 pps)
Output rate : 0 bps (0 pps)
Input errors: 0, Output errors: 0
Active alarms : None
Active defects : None
Logical interface fe-1/3/1.0 (Index 69) (SNMP ifIndex 50)
Flags: SNMP-Traps Encapsulation: ENET2
Protocol inet, MTU: 1500
Flags: Is-Primary, DCU, SCU-in
Packets Bytes
Destination class (packet-per-second) (bits-per-second)
silver1 0 0
( 0) ( 0)
silver2 0 0
( 0) ( 0)
silver3 0 0
( 0) ( 0)
Addresses, Flags: Is-Default Is-Preferred Is-Primary
Destination: 10.27.245/24, Local: 10.27.245.2,
Broadcast: 10.27.245.255
Protocol iso, MTU: 1497
Flags: Is-Primary

Sample Output

show interfaces switch-port

user@host# show interfaces ge-slot/0/0 switch-port port-number


Port 0, Physical link is Up
Speed: 100mbps, Auto-negotiation: Enabled
Statistics: Receive Transmit
Total bytes 28437086 21792250
Total packets 409145 88008
Unicast packets 9987 83817
Multicast packets 145002 0
Broadcast packets 254156 4191
Multiple collisions 23 10
954

FIFO/CRC/Align errors 0 0
MAC pause frames 0 0
Oversized frames 0
Runt frames 0
Jabber frames 0
Fragment frames 0
Discarded frames 0
Autonegotiation information:
Negotiation status: Complete
Link partner:
Link mode: Full-duplex, Flow control: None, Remote fault: OK, Link partner
Speed: 100 Mbps
Local resolution:
Flow control: None, Remote fault: Link OK

Sample Output

show interfaces transport pm

user@host> show interfaces transport pm all current et-0/1/0


Physical interface: et-0/1/0, SNMP ifIndex 515
14:45-current Elapse time:900 Seconds
Near End Suspect Flag:False Reason:None
PM COUNT THRESHOLD TCA-ENABLED TCA-RAISED
OTU-BBE 0 800 No No
OTU-ES 0 135 No No
OTU-SES 0 90 No No
OTU-UAS 427 90 No No
Far End Suspect Flag:True Reason:Unknown
PM COUNT THRESHOLD TCA-ENABLED TCA-RAISED
OTU-BBE 0 800 No No
OTU-ES 0 135 No No
OTU-SES 0 90 No No
OTU-UAS 0 90 No No
Near End Suspect Flag:False Reason:None
PM COUNT THRESHOLD TCA-ENABLED TCA-RAISED
ODU-BBE 0 800 No No
ODU-ES 0 135 No No
ODU-SES 0 90 No No
955

ODU-UAS 427 90 No No
Far End Suspect Flag:True Reason:Unknown
PM COUNT THRESHOLD TCA-ENABLED TCA-RAISED
ODU-BBE 0 800 No No
ODU-ES 0 135 No No
ODU-SES 0 90 No No
ODU-UAS 0 90 No No
FEC Suspect Flag:False Reason:None
PM COUNT THRESHOLD TCA-ENABLED TCA-RAISED
FEC-CorrectedErr 2008544300 0 NA NA
FEC-UncorrectedWords 0 0 NA NA
BER Suspect Flag:False Reason:None
PM MIN MAX AVG THRESHOLD TCA-ENABLED TCA-RAISED
BER 3.6e-5 5.8e-5 3.6e-5 10.0e-3 No Yes
Physical interface: et-0/1/0, SNMP ifIndex 515
14:45-current
Suspect Flag:True Reason:Object Disabled
PM CURRENT MIN MAX AVG THRESHOLD TCA-
ENABLED TCA-RAISED
(MIN) (MAX) (MIN)
(MAX) (MIN) (MAX)
Lane chromatic dispersion 0 0 0 0 0 0 NA
NA NA NA
Lane differential group delay 0 0 0 0 0 0 NA
NA NA NA
q Value 120 120 120 120 0 0
NA NA NA NA
SNR 28 28 29 28 0 0 NA
NA NA NA
Tx output power(0.01dBm) -5000 -5000 -5000 -5000 -300 -100 No
No No No
Rx input power(0.01dBm) -3642 -3665 -3626 -3637 -1800 -500 No
No No No
Module temperature(Celsius) 46 46 46 46 -5 75 No
No No No
Tx laser bias current(0.1mA) 0 0 0 0 0 0 NA
NA NA NA
Rx laser bias current(0.1mA) 1270 1270 1270 1270 0 0 NA
NA NA NA
Carrier frequency offset(MHz) -186 -186 -186 -186 -5000 5000 No
No No No
956

Sample Output

show security zones

user@host> show security zones


Functional zone: management
Description: This is the management zone.
Policy configurable: No
Interfaces bound: 1
Interfaces:
ge-0/0/0.0
Security zone: Host
Description: This is the host zone.
Send reset for non-SYN session TCP packets: Off
Policy configurable: Yes
Interfaces bound: 1
Interfaces:
fxp0.0
Security zone: abc
Description: This is the abc zone.
Send reset for non-SYN session TCP packets: Off
Policy configurable: Yes
Interfaces bound: 1
Interfaces:
ge-0/0/1.0
Security zone: def
Description: This is the def zone.
Send reset for non-SYN session TCP packets: Off
Policy configurable: Yes
Interfaces bound: 1
Interfaces:
ge-0/0/2.0

Release Information

Command modified in Junos OS Release 9.5.


957

set date ntp

IN THIS SECTION

Syntax | 957

Description | 957

Options | 957

Required Privilege Level | 958

Output Fields | 958

Sample Output | 958

Release Information | 959

Syntax

set date ntp <servers | force | key key | node node-number | routing-instance routing-instance-
name | source-address source-address>

Description

Set the date and local time. If reject mode is enabled and the system rejected the update from the NTP
server because it exceeds the configured threshold value, an administrator has two options to overrule
the reject mode action: manually set the date and time in YYYYMMDDhhmm.ss format, or force
synchronization of device time with the NTP server update by specifying the force option.

Options

servers Specify the IP address of one or more NTP servers.


958

force Force system date and time to update to NTP server values. The device date and
time are synchronized with the NTP proposed date and time even if reject is set as
the action and the difference between the device time and NTP proposed time
exceeds the default or the configured threshold value.

key key Specify a key number to authenticate the NTP server used to synchronize the date
and time. You must specify the same key number used to authenticate the server,
configured at the [edit system ntp authentication-key number] hierarchy level.

node node- Specify system date and time using NTP servers on specific node.
name
routing-instance Specify the routing instance through which server is available.
routing-
instance-name
source-address Specify the source address that the SRX Series devices use to contact the remote
source-address NTP server.

Required Privilege Level

view

Output Fields

When you enter this command, you are provided feedback on the status of your request.

Sample Output

set date ntp force

user@host> set date ntp force


18 Jul 16:52:43 ntpdate[3319]: NTP update request has been accepted, The time offset is
147605840.624994 sec from the time server 66.129.255.62 which is larger than the maximum
threshold of 400 sec allowed.
959

Release Information

Command introduced in Junos OS Release 15.1X49-D70.

RELATED DOCUMENTATION

show system ntp threshold | 959


ntp
ntp threshold | 675
NTP Time Synchronization on SRX Series Devices | 360

show system ntp threshold

IN THIS SECTION

Syntax | 959

Description | 960

Options | 960

Required Privilege Level | 960

Output Fields | 960

Sample Output | 961

Release Information | 961

Syntax

show system ntp threshold


960

Description

Display the current threshold and reject mode configured information.

Options

Required Privilege Level

view

Output Fields

lists the output fields for the Table 68 on page 960 show system ntp threshold command. Output fields are
listed in the approximate order in which they appear.

Table 68: show system ntp threshold Output Fields

Field Name Field Description

NTP threshold Assign a threshold value for Network Time Protocol (NTP) adjustment that is outside of the
acceptable NTP update and specify whether to accept or reject NTP synchronization when
the proposed time from the NTP server exceeds the configured threshold value.

Success Criteria Verifies the NTP threshold and provide the status of NTP adjustment mode (accept or reject).
961

Sample Output

show system ntp threshold

user@host> show system ntp threshold


NTP threshold: 400 sec
NTP adjustment reject mode is enabled
Success Criteria: verify threshold and reject mode can appear after user configuration.

Release Information

Command introduced in Junos OS Release 15.1X49-D70.

RELATED DOCUMENTATION

set date ntp | 957


ntp threshold | 675
ntp
NTP Time Synchronization on SRX Series Devices | 360

show security macsec connections

IN THIS SECTION

Syntax | 962

Description | 962

Options | 962

Required Privilege Level | 962

Output Fields | 962

Sample Output | 963


962

Release Information | 964

Syntax

show security macsec connections


<interface interface-name>

Description

Display the status of the active MACsec connections on the device.

Options

none Display MACsec connection information for all interfaces on the device.

interface interface- (Optional) Display MACsec connection information for the specified interface
name only.

Required Privilege Level

view

Output Fields

Table 69 on page 963 lists the output fields for the show security macsec connections command. Output
fields are listed in the approximate order in which they appear.
963

Table 69: show security macsec connections Output Fields

Field Name Field Description

Fields for Interface

Interface name Name of the interface.

CA name Name of the connectivity association.

A connectivity association is named using the connectivity-association


statement when you are enabling MACsec.

Cipher suite Name of the cipher suite used for encryption.

Key server offset Offset setting.

The offset is set using the offset statement when configuring the connectivity
association when using static connectivity association key (CAK) or dynamic
security mode.

Replay protect Replay protection setting. Replay protection is enabled when this output is on
and disabled when this output is off.

You can enable replay protection using the replay-protect statement in the
connectivity association.

Sample Output

show security macsec connections

user@host> show security macsec connections


Interface name: fxp1
CA name: ca1
Cipher suite: GCM-AES-128 Encryption: on
Key server offset: 0 Include SCI: no
964

Replay protect: off Replay window: 0

Release Information

Command introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

show security mka statistics | 970

show security macsec statistics (SRX Series


Firewalls)

IN THIS SECTION

Syntax | 965

Description | 965

Options | 965

Required Privilege Level | 965

Output Fields | 966

Sample Output | 969

Release Information | 970


965

Syntax

show security macsec statistics


<brief | detail>
<interface interface-name>

Description

Display Media Access Control Security (MACsec) statistics.

Options

none Display MACsec statistics in brief form for all interfaces on the switch.

brief | detail (Optional) Display the specified level of output. Using the brief option is equivalent to
entering the command with no options (the default). The detail option displays
additional fields that are not visible in the brief output.

NOTE: The field names that only appear in this command output when you
enter the detail option are mostly useful for debugging purposes by Juniper
Networks support personnel.

interface (Optional) Display MACsec statistics for the specified interface only.
interface-
name

Required Privilege Level

view
966

Output Fields

Table 70 on page 966 lists the output fields for the show security macsec statistics command. Output
fields are listed in the approximate order in which they appear.

The field names that appear in this command output only when you enter the detail option are mostly
useful for debugging purposes by Juniper Networks support personnel. Those field names are, therefore,
not included in this table.

Table 70: show security macsec statistics Output Fields

Field Name Field Description Level of Output

Interface name Name of the interface. All levels

Fields for Secure Channel transmitted

Encrypted packets Total number of packets transmitted out of the interface in All levels
the secure channel that were secured and encrypted using
MACsec.

Data packets are sent in the secure channel when MACsec


is enabled, and are secured using a connectivity association
key (CAK).

Encrypted bytes Total number of bytes transmitted out of the interface in All levels
the secure channel that were secured and encrypted using
MACsec.

Data packets are sent in the secure channel when MACsec


is enabled, and are secured using a connectivity association
key (CAK).

Protected packets Total number of packets transmitted out of the interface in All levels
the secure channel that were secured but not encrypted
using MACsec.

Data packets are sent in the secure channel when MACsec


is enabled, and are secured using a connectivity association
key (CAK).
967

Table 70: show security macsec statistics Output Fields (Continued)

Field Name Field Description Level of Output

Protected bytes Total number of bytes transmitted out of the interface in All levels
the secure channel that were secured but not encrypted
using MACsec.

Data packets are sent in the secure channel when MACsec


is enabled, and are secured using a connectivity association
key (CAK).

Fields for Secure Association transmitted

Encrypted packets Total number of packets transmitted out of the interface in All levels
the connectivity association that were secured and
encrypted using MACsec.

The total includes the data packets transmitted in the


secure channel and the control packets secured using a
connectivity association key (CAK).

Protected packets Total number of packets transmitted out of the interface in All levels
the connectivity association that were secured but not
encrypted using MACsec.

The total includes the data packets transmitted in the


secure channel and the control packets secured using a
connectivity association key (CAK).

Fields for Secure Channel received

Accepted packets The number of received packets that have been accepted All levels
by the secure channel on the interface. The secure channel
is used to send all data plane traffic on a MACsec-enabled
link.

A packet is considered accepted for this counter when it


has been received by this interface and it has passed the
MACsec integrity check.

This counter increments for traffic that is and is not


encrypted using MACsec.
968

Table 70: show security macsec statistics Output Fields (Continued)

Field Name Field Description Level of Output

Validated bytes The number of bytes that have been validated by the All levels
MACsec integrity check and received on the secure channel
on the interface. The secure channel is used to send all data
plane traffic on a MACsec-enabled link.

This counter does not increment when MACsec encryption


is disabled.

Decrypted bytes The number of bytes received in the secure channel on the All levels
interface that have been decrypted. The secure channel is
used to send all data plane traffic on a MACsec-enabled
link.

An encrypted byte has to be decrypted before it can be


received on the receiving interface. The decrypted bytes
counter is incremented for received traffic that was
encrypted using MACsec.

Fields for Secure Association received

Accepted packets The number of received packets that have been accepted in All levels
the connectivity association on the interface. The counter
includes all control and data plane traffic accepted on the
interface.

A packet is considered accepted for this counter when it


has been received by this interface and it has passed the
MACsec integrity check.

Validated bytes The number of bytes that have been validated by the All levels
MACsec integrity check and received on the connectivity
association on the interface. The counter includes all
control and data plane traffic accepted on the interface.

This counter does not increment when MACsec encryption


is disabled.
969

Table 70: show security macsec statistics Output Fields (Continued)

Field Name Field Description Level of Output

Decrypted bytes The number of bytes received in the connectivity All levels
association on the interface that have been decrypted. The
counter includes all control and data plane traffic accepted
on the interface.

An encrypted byte has to be decrypted before it can be


received on the receiving interface. The decrypted bytes
counter is incremented for received traffic that was
encrypted using MACsec.

Sample Output

show security macsec statistics interface

user@host> show security macsec statistics interface fxp1 detail

Interface name: fxp1


Secure Channel transmitted
Encrypted packets: 2397305
Encrypted bytes: 129922480
Protected packets: 0
Protected bytes: 0
Secure Association transmitted
Encrypted packets: 2397305
Protected packets: 0
Secure Channel received
Accepted packets: 2395850
Validated bytes: 0
Decrypted bytes: 131715088
Secure Association received
Accepted packets: 2395850
Validated bytes: 0
Decrypted bytes: 0
970

Release Information

Command introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656
show interfaces (Gigabit Ethernet)
show security mka sessions (SRX Series Device | 974

show security mka statistics

IN THIS SECTION

Syntax | 970

Description | 971

Options | 971

Required Privilege Level | 971

Output Fields | 971

Sample Output | 973

Release Information | 973

Syntax

show security mka statistics


<interface interface-name>
971

Description

Display MACsec Key Agreement (MKA) protocol statistics.

The output for this command does not include statistics for MACsec data traffic. For MACsec data
traffic statistics, see "show security macsec statistics (SRX Series Devices)" on page 964.

Options

• interface interface-name—(Optional) Display the MKA information for the specified interface only.

Required Privilege Level

view

Output Fields

Table 71 on page 971 lists the output fields for the show security mka statistics command. Output fields
are listed in the approximate order in which they appear.

Table 71: show security mka statistics Output Fields

Field Name Field Description

Received packets Number of received MKA control packets.

This counter increments for received MKA control packets only. This counter
does not increment when data packets are received.

Transmitted packets Number of transmitted MKA packets

This counter increments for transmitted MKA control packets only. This
counter does not increment when data packets are transmitted.

Version mismatch packets Number of version mismatch packets.


972

Table 71: show security mka statistics Output Fields (Continued)

Field Name Field Description

CAK mismatch packets Number of Connectivity Association Key (CAK) mismatch packets.

This counter increments when the connectivity association key (CAK) and
connectivity association key name (CKN), which are user-configured values
that have to match to enable MACsec, do not match for an MKA control
packet.

ICV mismatch packets Number of ICV mismatched packets.

This counter increments when the connectivity association key (CAK) value
does not match on both ends of a MACsec-secured Ethernet link.

Duplicate message identifier Number of duplicate message identifier packets.


packets

Duplicate message number Number of duplicate message number packets.


packets

Duplicate address packets Number of duplicate source MAC address packets.

Invalid destination address Number of invalid destination MAC address packets.


packets

Formatting error packets Number of formatting error packets.

Old Replayed message number Number of old replayed message number packets.
packets
973

Sample Output

show security mka statistics

user@host> show security mka statistics

Interface name: fxp1


Received packets: 3
Transmitted packets: 14
Version mismatch packets: 0
CAK mismatch packets: 0
ICV mismatch packets: 0
Duplicate message identifier packets: 0
Duplicate message number packets: 0
Duplicate address packets: 0
Invalid destination address packets: 0
Formatting error packets: 0
Old Replayed message number packets: 0

Release Information

Command introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656
show interfaces (Gigabit Ethernet)
show security macsec statistics (SRX Series Firewalls) | 964
974

show security mka sessions (SRX Series Device

IN THIS SECTION

Syntax | 974

Description | 974

Options | 974

Required Privilege Level | 975

Output Fields | 975

Sample Output | 976

Release Information | 977

Syntax

show security mka sessions


<interface interface-name>

Description

Display MACsec Key Agreement (MKA) session information.

Options

• interface interface-name—(Optional) Display the MKA information for the specified interface only.
975

Required Privilege Level

view

Output Fields

Table 72 on page 975 lists the output fields for the show security mka sessions command. Output fields
are listed in the approximate order in which they appear.

Table 72: show security mka sessions Output Fields

Field Name Field Description

Interface name Name of the interface.

Member identifier Name of the member identifier.

CAK name Name of the Connectivity Association Key (CAK..

The CAK is configured using the cak keyword when configuring the pre-shared
key.

Transmit interval The transmit interval.

Outbound SCI Name of the outbound secure channel identifier.

Message number Number of the last data message.

Key server Key server status.

The switch is the key server when this output is yes. The switch is not the key
server when this output is no.

Key number Key number.


976

Table 72: show security mka sessions Output Fields (Continued)

Field Name Field Description

Key server priority The key server priority.

The key server priority can be set using the key-server-priority statement.

Latest SAK AN Name of the latest secure association key (SAK) association number.

Latest SAK KI Name of the latest secure association key (SAK) key identifier.

Previous SAK AN Name of the previous secure association key (SAK) association number.

Previous SAK KI Name of the previous secure association key (SAK) key identifier.

Sample Output

show security mka sessions

user@host> show security mka sessions

Interface name: fxp1


Member identifier: 71235CA1B78D0AF7B3F29CFB
CAK name: AAAA
Transmit interval: 10000(ms)
Outbound SCI: 30:7C:5E:44:98:42/1
Message number: 2326 Key number: 2
Key server: yes Key server priority: 16
Latest SAK AN: 1 Latest SAK KI: 71235CA1B78D0AF7B3F29CFB/2
Previous SAK AN: 0 Previous SAK KI: 71235CA1B78D0AF7B3F29CFB/1
977

Release Information

Command introduced in Junos OS Release 15.1X49-D60.

RELATED DOCUMENTATION

Understanding Media Access Control Security (MACsec) | 486


Configuring Media Access Control Security (MACsec) | 489
macsec | 656
show interfaces (Gigabit Ethernet)
show security macsec statistics (SRX Series Firewalls) | 964

show security internal-security-association

IN THIS SECTION

Syntax | 977

Description | 978

Required Privilege Level | 978

Output Fields | 978

Sample Output | 978

Release Information | 979

Syntax

show security internal-security-association


978

Description

Provide secure login by enabling the internal security association in a chassis cluster configuration.

Required Privilege Level

view

Output Fields

Table 73 on page 978 lists the output fields for the show security internal-security-association command.
Output fields are listed in the approximate order in which they appear.

Table 73: show security internal-security-association Output Fields

Field Name Field Description

Internal SA Status State of the internal SA option on the chassis cluster control link: enabled or
disabled.

Iked Encryption Status State of the iked encryption.

Sample Output

show security internal-security-association

user@host>show security internal-security-association

node0:
--------------------------------------------------------------------------
Internal SA Status : Enabled
Iked Encryption Status : Enabled
979

node1:
--------------------------------------------------------------------------
Internal SA Status : Enabled
Iked Encryption Status : Enabled

Release Information

Command introduced in Junos OS Release 12.1X47-D10.

RELATED DOCUMENTATION

Chassis Cluster User Guide for SRX Series Devices

show system license (View)

IN THIS SECTION

Syntax | 979

Description | 980

Options | 980

Required Privilege Level | 980

Output Fields | 980

Sample Output | 981

Release Information | 983

Syntax

show system license


<installed | keys | status | usage>
980

Description

Display licenses and information about how licenses are used.

Options

none Display all license information.

installed (Optional) Display installed licenses only.

keys (Optional) Display a list of license keys. Use this information to verify that each expected
license key is present.

status (Optional) Display license status for a specified logical system or for all logical systems.

usage (Optional) Display the state of licensed features.

Required Privilege Level

view

Output Fields

Table 74 on page 980 lists the output fields for the show system license command. Output fields are listed
in the approximate order in which they appear.

Table 74: show system license Output Fields

Field Name Field Description

Feature name Name assigned to the configured feature. You use this information to verify that all the
features for which you installed licenses are present.
981

Table 74: show system license Output Fields (Continued)

Field Name Field Description

Licenses used Number of licenses used by the device. You use this information to verify that the number
of licenses used matches the number configured. If a licensed feature is configured, the
feature is considered used.

Licenses installed Information about the installed license key:

• License identifier—Identifier associated with a license key.

• License version—Version of a license. The version indicates how the license is validated,
the type of signature, and the signer of the license key.

• Valid for device—Device that can use a license key.

• Features—Feature associated with a license.

Licenses needed Number of licenses required for features being used but not yet properly licensed.

Expiry Time remaining in the grace period before a license is required for a feature being used.

Logical system Displays whether a license is enabled for a logical system.


license status

Sample Output

show system license

user@host> show system license

License usage:
Licenses Licenses Licenses Expiry
Feature name used installed needed
av_key_kaspersky_engine 1 1 0 2012-03-30 01:00:00 IST
wf_key_surfcontrol_cpa 0 1 0 2012-03-30 01:00:00 IST
dynamic-vpn 0 1 0 permanent
982

ax411-wlan-ap 0 2 0 permanent

Licenses installed:
License identifier: JUNOS301998
License version: 2
Valid for device: AG4909AA0080
Features:
av_key_kaspersky_engine - Kaspersky AV
date-based, 2011-03-30 01:00:00 IST - 2012-03-30 01:00:00 IST

License identifier: JUNOS302000


License version: 2
Valid for device: AG4909AA0080
Features:
wf_key_surfcontrol_cpa - Web Filtering
date-based, 2011-03-30 01:00:00 IST - 2012-03-30 01:00:00 IST

show system license installed

user@host> show system license installed

License identifier: JUNOS301998


License version: 2
Valid for device: AG4909AA0080
Features:
av_key_kaspersky_engine - Kaspersky AV
date-based, 2011-03-30 01:00:00 IST - 2012-03-30 01:00:00 IST

License identifier: JUNOS302000


License version: 2
Valid for device: AG4909AA0080
Features:
wf_key_surfcontrol_cpa - Web Filtering
date-based, 2011-03-30 01:00:00 IST - 2012-03-30 01:00:00 IST

show system license keys

user@host> show system license keys

XXXXXXXXXX xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx


983

xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx xxxxxx


xxxxxx xxxxxx xxx

show system license usage

user@host> show system license usage

Licenses Licenses Licenses Expiry


Feature name used installed needed
av_key_kaspersky_engine 1 1 0 2012-03-30 01:00:00 IST
wf_key_surfcontrol_cpa 0 1 0 2012-03-30 01:00:00 IST
dynamic-vpn 0 1 0 permanent
ax411-wlan-ap 0 2 0 permanent

show system license status logical-system all

user@host> show system license status logical-system all


Logical system license status:

logical system name license status


root-logical-system enabled
LSYS0 enabled
LSYS1 enabled
LSYS2 enabled

Release Information

Command introduced in Junos OS Release 9.5. Logical system status option added in Junos OS Release
11.2.

RELATED DOCUMENTATION

Adding New Licenses (CLI Procedure)


984

show vrrp

IN THIS SECTION

Syntax | 984

Description | 984

Options | 984

Required Privilege Level | 985

Output Fields | 985

Sample Output | 993

Release Information | 998

Syntax

show vrrp
<brief | detail | extensive | summary>
<interface�interface-name>
<logical-system�logical-system-name>
<nsr>
<track�track-interfaces>

Description

Display information and status about VRRP groups.

Options

none (Same as brief) Display brief status information about all VRRP interfaces.
985

brief | detail | extensive | (Optional) Display the specified level of output.


summary
interface interface-name (Optional) Display information and status about the specified VRRP
interface.

logical-system (Optional) Display information and status about the specified logical
system.

nsr (Optional) Display information and status about the primary routing engine.

track track-interfaces (Optional) Display information and status about VRRP track interfaces.

Required Privilege Level

view

Output Fields

Table 75 on page 985 lists the output fields for the show vrrp command. Output fields are listed in the
approximate order in which they appear.

Table 75: show vrrp Output Fields

Field Name Field Description Level of Output

Interface Name of the logical interface. none, brief,


extensive, summary

Interface index Physical interface index number, which reflects its initialization extensive
sequence.

Groups Total number of VRRP groups configured on the interface. extensive

Active Total number of VRRP groups that are active (that is, whose interface extensive
state is either up or down).
986

Table 75: show vrrp Output Fields (Continued)

Field Name Field Description Level of Output

Interface VRRP Nonerrored statistics for the logical interface: extensive


PDU statistics
• Advertisement sent�Number of VRRP advertisement protocol data
units (PDUs) that the interface has transmitted.

• Advertisement received�Number of VRRP advertisement PDUs


received by the interface.

• Packets received�Number of VRRP packets received for VRRP


groups on the interface.

• No group match received�Number of VRRP packets received for


VRRP groups that do not exist on the interface.

Interface VRRP Errored statistics for the logical interface: extensive


PDU error
statistics • Invalid IPAH next type received�Number of packets received that
use the IP Authentication Header protocol (IPAH) and that do not
encapsulate VRRP packets.

• Invalid VRRP ttl value received�Number of packets received whose


IP time- to-live (TTL) value is not�255.

• Invalid VRRP version received�Number of packets received whose


VRRP version is not 2.

• Invalid VRRP pdu type received�Number of packets received whose


VRRP PDU type is not 1.

• Invalid VRRP authentication type received�Number of packets


received whose VRRP authentication is not none, simple, or md5.

• Invalid VRRP IP count received�Number of packets received whose


VRRP IP count exceeds 8.

• Invalid VRRP checksum received�Number of packets received


whose VRRP checksum does not match the calculated value.

Physical Name of the physical interface. detail, extensive


interface
987

Table 75: show vrrp Output Fields (Continued)

Field Name Field Description Level of Output

Unit Logical unit number. All levels

Address Address of the physical interface. none, brief, detail,


extensive

Index Physical interface index number, which reflects its initialization detail, extensive
sequence.

SNMP ifIndex SNMP index number for the physical interface. detail, extensive

VRRP-Traps Status of VRRP traps: Enabled or Disabled. detail, extensive

Type and Identifier for the address and the address itself: none, brief, summary
Address
• lcl�Configured local interface address.

• mas�Address of the primary device. This address is displayed only


when the local interface is acting as a backup device.

• vip�Configured virtual IP addresses.

Interface state or State of the physical interface: none, brief,


Int state extensive, summary
• down�The device is present and the link is unavailable.

• not present�The interface is configured, but no physical device is


present.

• unknown�The VRRP process has not had time to query the kernel
about the state of the interface.

• up�The device is present and the link is established.

Group VRRP group number. none, brief,


extensive, summary
988

Table 75: show vrrp Output Fields (Continued)

Field Name Field Description Level of Output

State VRRP state: extensive

• backup�The interface is acting as the backup device interface.

• bringup�VRRP is just starting, and the physical device is not yet


present.

• idle�VRRP is configured on the interface and is disabled. This can


occur when VRRP is first enabled on an interface whose link is
established.

• initializing�VRRP is initializing.

• master�The interface is acting as the primary device interface.

• transition�The interface is changing between being the backup and


being the primary device.

Priority Configured VRRP priority for the interface. detail, extensive

Advertisement Configured VRRP advertisement interval. detail, extensive


interval

Authentication Configured VRRP authentication type: none, simple, or md5. detail, extensive
type

Preempt Whether preemption is allowed on the interface: yes or no. detail, extensive

Accept-data Whether the interface is configured to accept packets destined for the detail, extensive
mode virtual IP address: yes or no.

VIP count Number of virtual IP addresses that have been configured on the detail, extensive
interface.

VIP List of virtual IP addresses configured on the interface. detail, extensive


989

Table 75: show vrrp Output Fields (Continued)

Field Name Field Description Level of Output

Advertisement Time until the advertisement timer expires. detail, extensive


timer

Master router IP address of the interface that is acting as the primary. If the VRRP detail, extensive
interface is down, the output is N/A.

Virtual router Time that the virtual device has been up. detail, extensive
uptime

Master router Time that the primary device has been up. detail, extensive
uptime

Virtual MAC MAC address associated with the virtual IP address. detail, extensive

Tracking Whether tracking is enabled or disabled. detail, extensive

Current priority Current operational priority for being the VRRP primary. detail, extensive

Configured Configured base priority for being the VRRP primary. detail, extensive
priority

Priority hold- Minimum time interval, in seconds, between successive changes to the detail, extensive
time current priority. Disabled indicates no minimum interval.

Remaining-time (track option only) Displays the time remaining in the priority hold-time detail
interval.

Interface Whether interface tracking is enabled or disabled. When enabled, the detail extensive
tracking output also displays the number of tracked interfaces.

Interface/ Name of the tracked interface. detail extensive


Tracked interface
990

Table 75: show vrrp Output Fields (Continued)

Field Name Field Description Level of Output

Int state/ Current operational state of the tracked interface: up or down. detail, extensive
Interface state

Int speed/Speed Current operational speed, in bits per second, of the tracked interface. detail, extensive

Incurred priority Operational priority cost incurred due to the state and speed of this detail, extensive
cost tracked interface. This cost is applied to the configured priority to
obtain the current priority.

Threshold Speed below which the corresponding priority cost is incurred. In other detail, extensive
words, when the speed of the interface drops below the threshold
speed, the corresponding priority cost is incurred.

An entry of down means that the corresponding priority cost is incurred


when the interface is down.

Route tracking Whether route tracking is enabled or disabled. When enabled, the detail, extensive
output also displays the number of tracked routes.

Route count The number of routes being tracked. detail, extensive

Route The IP address of the route being tracked. detail, extensive

VRF name The VPN routing and forwarding (VRF) routing instance that the tracked detail, extensive
route is in.

Route state The state of the route being tracked: up, down, or unknown. detail, extensive

Priority cost Configured priority cost. This value is incurred when the interface speed detail, extensive
drops below the corresponding threshold or when the tracked route
goes down.

Active Whether the threshold is active (*). If the threshold is active, the detail, extensive
corresponding priority cost is incurred.
991

Table 75: show vrrp Output Fields (Continued)

Field Name Field Description Level of Output

Group VRRP Number of VRRP advertisements sent and received by the group. extensive
PDU statistics

Group VRRP Errored statistics for the VRRP group: extensive


PDU error
statistics • Bad authentication type received�Number of VRRP PDUs received
with an invalid authentication type. The received authentication can
be none, simple, or md5 and must be the same for all devices in the
VRRP group.

• Bad password received�Number of VRRP PDUs received with an


invalid key (password). The password for simple authentication must
be the same for all devices in the VRRP group

• Bad MD5 digest received�Number of VRRP PDUs received for


which the MD5 digest computed from the VRRP PDU differs from
the digest expected by the VRRP instance configured on the device.

• Bad advertisement timer received�Number of VRRP PDUs received


with an advertisement time interval that is inconsistent with the one
in use among the devices in the VRRP group.

• Bad VIP count received�Number of VRRP PDUs whose virtual IP


address counts differ from the count that has been configured on
the VRRP instance.

• Bad VIPADDR received�Number of VRRP PDUs whose virtual IP


addresses differ from the list of virtual IP addresses configured on
the VRRP instance.
992

Table 75: show vrrp Output Fields (Continued)

Field Name Field Description Level of Output

Group state State transition statistics for the VRRP group: extensive
transition
statistics • Idle to master transitions�Number of times that the VRRP instance
transitioned from the idle state to the primary state.

• Idle to backup transitions�Number of times that the VRRP instance


transitioned from the idle state to the backup state.

• Backup to master transitions�Number of times that the VRRP


instance transitioned from the backup state to the primary state.

• Master to backup transitions�Number of times that the VRRP


instance transitioned from the primary state to the backup state.

Vlan-id ID of Vlan detail

VR state VRRP information: none, brief

• backup�The interface is acting as the backup device interface.

• bringup�VRRP is just starting, and the physical device is not yet


present.

• idle�VRRP is configured on the interface and is disabled. This can


occur when VRRP is first enabled on an interface whose link is
established.

• initializing�VRRP is initializing.

• master�The interface is acting as the primary device interface.

• transition�The interface is changing between being the backup and


being the primary device.

Timer VRRP timer information: none, brief

• A�Time, in seconds, until the advertisement timer expires.

• D�Time, in seconds, until the Primary is Dead timer expires.


993

Sample Output

show vrrp

user@host> show vrrp


Interface State Group VR state Timer Type Address
ge-0/0/0.121 up 1 master A 1.052 lcl
ge2001:db8::12:1:1:1
vip
ge2001:db8:0:1:12:1:1:99
vip
ge2001:db8::12:1:1:99
ge-0/0/2.131 up 1 master A 0.364 lcl
ge2001:db8::13:1:1:1
vip
ge2001:db8:0:1:13:1:1:99
vip
ge2001:db8::13:1:1:99

show vrrp brief

The output for the show vrrp brief command is identical to that for the show vrrp command. For sample
output, see "show vrrp" on page 993.

show vrrp detail (IPv6)

user@host> show vrrp detail


Physical interface: ge-0/0/0, Unit: 121, Vlan-id: 212, Address: ge2001:db8::12:1:1:1/120
Index: 67, SNMP ifIndex: 45, VRRP-Traps: enabled
Interface state: up, Group: 1, State: master
Priority: 200, Advertisement interval: 1, Authentication type: none
Preempt: yes, Accept-data mode: no, VIP count: 2, VIP: ge2001:db8:0:1:12:1:1:99,
ge2001:db8::12:1:1:99
Advertisement timer: 1.121s, Master router: ge2001:db8:0:1:12:1:1:1
Virtual router uptime: 00:03:47, Master router uptime: 00:03:41
Virtual MAC: 00:00:5e:00:02:01
Tracking: disabled

Physical interface: ge-0/0/2, Unit: 131, Vlan-id: 213, Address: ge2001:db8::13:1:1:1/120


Index: 69, SNMP ifIndex: 47, VRRP-Traps: enabled
994

Interface state: up, Group: 1, State: master


Priority: 200, Advertisement interval: 1, Authentication type: none
Preempt: yes, Accept-data mode: no, VIP count: 2, VIP: ge2001:db8:0:1:13:1:1:99,
ge2001:db8::13:1:1:99
Advertisement timer: 0.327s, Master router: ge2001:db8:0:1:13:1:1:1
Virtual router uptime: 00:03:47, Master router uptime: 00:03:41
Virtual MAC: 00:00:5e:00:02:01
Tracking: disabled

show vrrp detail (Route Track)

user@host> show vrrp detail


Physical interface: ge-1/1/0, Unit: 0, Address: 192.0.2.30/24
Index: 67, SNMP ifIndex: 379, VRRP-Traps: enabled
Interface state: up, Group: 100, State: master
Priority: 150, Advertisement interval: 1, Authentication type: none
Preempt: yes, Accept-data mode: no, VIP count: 1, VIP: 192.0.2.100
Advertisement timer: 1.218s, Master router: 192.0.2.30
Virtual router uptime: 00:04:28, Master router uptime: 00:00:13
Virtual MAC: 00:00:5e:00:01:64
Tracking: enabled
Current priority: 150, Configured priority: 150
Priority hold-time: disabled
Interface tracking: disabled
Route tracking: enabled, Route count: 1
Route VRF name Route state Priority cost
198.51.100.0/24 default up 30

show vrrp extensive

user@host> show vrrp extensive


Interface: ge-0/0/0.121, Interface index: 67, Groups: 1, Active : 1
Interface VRRP PDU statistics
Advertisement sent : 188
Advertisement received : 0
Packets received : 0
No group match received : 0
Interface VRRP PDU error statistics
Invalid IPAH next type received : 0
Invalid VRRP TTL value received : 0
995

Invalid VRRP version received : 0


Invalid VRRP PDU type received : 0
Invalid VRRP authentication type received: 0
Invalid VRRP IP count received : 0
Invalid VRRP checksum received : 0

Physical interface: ge-0/0/0, Unit: 121, Vlan-id: 212, Address: ge2001:db8::12:1:1:1/120


Index: 67, SNMP ifIndex: 45, VRRP-Traps: enabled
Interface state: up, Group: 1, State: master
Priority: 200, Advertisement interval: 1, Authentication type: none
Preempt: yes, Accept-data mode: no, VIP count: 2, VIP: ge2001:db8:0:1:12:1:1:99,
ge2001:db8::12:1:1:99
Advertisement timer: 1.034s, Master router: ge2001:db8:0:1:12:1:1:1
Virtual router uptime: 00:04:04, Master router uptime: 00:03:58
Virtual MAC: 00:00:5e:00:02:01
Tracking: disabled
Group VRRP PDU statistics
Advertisement sent : 188
Advertisement received : 0
Group VRRP PDU error statistics
Bad authentication type received: 0
Bad password received : 0
Bad MD5 digest received : 0
Bad advertisement timer received: 0
Bad VIP count received : 0
Bad VIPADDR received : 0
Group state transition statistics
Idle to master transitions : 0
Idle to backup transitions : 1
Backup to master transitions : 1
Master to backup transitions : 0

Interface: ge-0/0/2.131, Interface index: 69, Groups: 1, Active : 1


Interface VRRP PDU statistics
Advertisement sent : 186
Advertisement received : 0
Packets received : 0
No group match received : 0
Interface VRRP PDU error statistics
Invalid IPAH next type received : 0
Invalid VRRP TTL value received : 0
Invalid VRRP version received : 0
Invalid VRRP PDU type received : 0
996

Invalid VRRP authentication type received: 0


Invalid VRRP IP count received : 0
Invalid VRRP checksum received : 0

Physical interface: ge-0/0/2, Unit: 131, Vlan-id: 213, Address: ge2001:db8::13:1:1:1/120


Index: 69, SNMP ifIndex: 47, VRRP-Traps: enabled
Interface state: up, Group: 1, State: master
Priority: 200, Advertisement interval: 1, Authentication type: none
Preempt: yes, Accept-data mode: no, VIP count: 2, VIP: ge2001:db8:0:1:13:1:1:99,
ge2001:db8::13:1:1:99
Advertisement timer: 0.396s, Master router: ge2001:db8:0:1:13:1:1:1
Virtual router uptime: 00:04:04, Master router uptime: 00:03:58
Virtual MAC: 00:00:5e:00:02:01
Tracking: disabled
Group VRRP PDU statistics
Advertisement sent : 186
Advertisement received : 0
Group VRRP PDU error statistics
Bad authentication type received: 0
Bad password received : 0
Bad MD5 digest received : 0
Bad advertisement timer received: 0
Bad VIP count received : 0
Bad VIPADDR received : 0
Group state transition statistics
Idle to master transitions : 0
Idle to backup transitions : 1
Backup to master transitions : 1
Master to backup transitions : 0

show vrrp interface

user@host> show vrrp interface


Interface: ge-0/0/0.121, Interface index: 67, Groups: 1, Active : 1
Interface VRRP PDU statistics
Advertisement sent : 205
Advertisement received : 0
Packets received : 0
No group match received : 0
Interface VRRP PDU error statistics
Invalid IPAH next type received : 0
997

Invalid VRRP TTL value received : 0


Invalid VRRP version received : 0
Invalid VRRP PDU type received : 0
Invalid VRRP authentication type received: 0
Invalid VRRP IP count received : 0
Invalid VRRP checksum received : 0

Physical interface: ge-0/0/0, Unit: 121, Vlan-id: 212, Address: ge2001:db8::12:1:1:1/120


Index: 67, SNMP ifIndex: 45, VRRP-Traps: enabled
Interface state: up, Group: 1, State: master
Priority: 200, Advertisement interval: 1, Authentication type: none
Preempt: yes, Accept-data mode: no, VIP count: 2, VIP: ge2001:db8:0:1:12:1:1:99,
gec2001:db8::12:1:1:99
Advertisement timer: 0.789s, Master router: ge2001:db8:0:1:12:1:1:1
Virtual router uptime: 00:04:26, Master router uptime: 00:04:20
Virtual MAC: 00:00:5e:00:02:01
Tracking: disabled
Group VRRP PDU statistics
Advertisement sent : 205
Advertisement received : 0
Group VRRP PDU error statistics
Bad authentication type received: 0
Bad password received : 0
Bad MD5 digest received : 0
Bad advertisement timer received: 0
Bad VIP count received : 0
Bad VIPADDR received : 0
Group state transition statistics
Idle to master transitions : 0
Idle to backup transitions : 1
Backup to master transitions : 1
Master to backup transitions : 0

show vrrp summary

user@host> show vrrp summary


Interface State Group VR state Type Address
ge-3/2/6.0 up 1 backup lcl 10.57.0.2
vip 10.57.0.100
998

show vrrp track detail

user@host> show vrrp track detail


Tracked interface: ae1.211
State: up, Speed: 400m
Incurred priority cost: 0
Threshold Priority cost Active
400m 10
300m 60
200m 110
100m 160
down 190
Tracking VRRP interface: ae0.210, Group: 1
VR State: master
Current priority: 200, Configured priority: 200
Priority hold-time: disabled, Remaining-time: 50.351

show vrrp track summary

user@host> show vrrp track summary


Track if State Speed VRRP if Group VR State Current priority
ae1.211 up 400m ae0.210 1 master 200

Release Information

Statement introduced in Junos OS Release 18.1R1.

RELATED DOCUMENTATION

Configuring VRRP for IPv6 (CLI Procedure)


Understanding VRRP on SRX Series Firewalls | 329
Example: Configuring VRRP/VRRPv3 on Chassis Cluster Redundant Ethernet Interfaces
9 CHAPTER

Chassis Cluster Support on SRX100,


SRX210, SRX220, SRX240, SRX650,
SRX1400, SRX3400, and SRX3600
Devices

Chassis Cluster Support on SRX100, SRX210, SRX220, SRX240, SRX650,


SRX1400, SRX3400, and SRX3600 Devices | 1000
1000

Chassis Cluster Support on SRX100, SRX210,


SRX220, SRX240, SRX650, SRX1400, SRX3400, and
SRX3600 Devices

IN THIS SECTION

SRX Series Chassis Cluster Configuration Overview | 1000

Flow and Processing | 1000

Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming for SRX100, SRX210,
SRX220, SRX240, and SRX650 | 1001

Chassis Cluster Slot Numbering and Physical Port and Logical Interface Naming for SRX3600, SRX3400, and
SRX1400 | 1005

Supported Fabric Interface Types for SRX Series Firewalls (SRX210, SRX240, SRX220, SRX100, and SRX650
Devices) | 1011

Redundant Ethernet Interfaces | 1012

Control Links | 1012

ISSU System Requirements for SRX1400, SRX3400 and SRX3600 | 1014

This topic includes the supported information for SRX100, SRX210, SRX220, SRX240, SRX650,
SRX1400, SRX3400, and SRX3600 devices.

SRX Series Chassis Cluster Configuration Overview

Following are the prerequisites for configuring a chassis cluster:

Flow and Processing

Flowd monitoring is supported on SRX100, SRX210, SRX 220, SRX240, and SRX650 devices.
1001

Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming for SRX100, SRX210, SRX220, SRX240, and SRX650

Information about chassis cluster slot numbering is also provided in Figure 50 on page 1001, Figure 51
on page 1001, Figure 52 on page 1001, Figure 53 on page 1002, and Figure 54 on page 1002.

Figure 50: Chassis Cluster Slot Numbering for SRX100 Devices

Figure 51: Chassis Cluster Slot Numbering for SRX210 Devices

Figure 52: Chassis Cluster Slot Numbering for SRX220 Devices


1002

Figure 53: Chassis Cluster Slot Numbering for SRX240 Devices

Figure 54: Chassis Cluster Slot Numbering for SRX650 Devices

Layer 2 switching must not be enabled on an SRX Series Firewall when chassis clustering is enabled. If
you have enabled Layer 2 switching, make sure you disable it before enabling chassis clustering.

The factory default configuration for SRX100, SRX210, and SRX220 devices automatically enables Layer
2 Ethernet switching. Because Layer 2 Ethernet switching is not supported in chassis cluster mode, if
you use the factory default configuration for these devices, you must delete the Ethernet switching
configuration before you enable chassis clustering. See Disabling Switching on SRX100, SRX210, and
SRX220 Devices Before Enabling Chassis Clustering.

In chassis cluster mode, the interfaces on the secondary node are renumbered internally. For example,
the management interface port on the front panel of each SRX210 device is still labeled fe-0/0/6, but
internally, the node 1 port is referred to as fe-2/0/6.

For SRX650 devices, control interfaces are dedicated Gigabit Ethernet ports.

For SRX100, SRX220, and SRX210 devices, after you enable chassis clustering and reboot the system,
the built-in interface named fe-0/0/6 is repurposed as the management interface and is automatically
renamed fxp0.

For SRX550 devices, control interfaces are dedicated Gigabit Ethernet ports.

For SRX210 devices, after you enable chassis clustering and reboot the system, the built-in interface
named fe-0/0/7 is repurposed as the control interface and is automatically renamed fxp1.
1003

In chassis cluster mode, the interfaces on the secondary node are renumbered internally. For example,
the management interface port on the front panel of each SRX210 device is still labeled fe-0/0/6, but
internally, the node 1 port is referred to as fe-2/0/6.

For SRX240 devices, control interfaces are dedicated Gigabit Ethernet ports. For SRX100 and SRX220
devices, after you enable chassis clustering and reboot the system, the built-in interface named fe-0/0/7
is repurposed as the control interface and is automatically renamed fxp1.

NOTE: For SRX210 Services Gateways, the base and enhanced versions of a model can be used
to form a cluster. For example:

• SRX210B and SRX210BE

• SRX210H and SRX210HE

However, the following combinations cannot be used to form a cluster:

• SRX210B and SRX210H

• SRX210B and SRX210HE

• SRX210BE and SRX210H

• SRX210BE and SRX210HE

Figure 55 on page 1003, Figure 56 on page 1004, Figure 57 on page 1004, Figure 58 on page 1004,
Figure 59 on page 1005, Figure 60 on page 1005 and all show pairs of SRX Series Firewalls with the
fabric links and control links connected.

Figure 55: Connecting SRX100 Devices in a Chassis Cluster


1004

Figure 56: Connecting SRX110 Devices in a Chassis Cluster

Figure 57: Connecting SRX210 Devices in a Chassis Cluster

Figure 58: Connecting SRX220 Devices in a Chassis Cluster


1005

Figure 59: Connecting SRX240 Devices in a Chassis Cluster

Figure 60: Connecting SRX650 Devices in a Chassis Cluster

The fabric link connection for the SRX100 and SRX210 must be a pair of either Fast Ethernet or Gigabit
Ethernet interfaces. The fabric link connection must be any pair of either Gigabit Ethernet or 10-Gigabit
Ethernet interfaces on all SRX Series Firewalls.

For some SRX Series Firewalls, such as the SRX100 and SRX200 line devices, do not have a dedicated
port for fxp0. For SRX100, SRX210, the fxp0 interface is repurposed from a built-in interface.

Chassis Cluster Slot Numbering and Physical Port and Logical Interface
Naming for SRX3600, SRX3400, and SRX1400

Table 76 on page 1006 shows the slot numbering, as well as the physical port and logical interface
numbering, for both of the SRX Series Firewalls that become node 0 and node 1 of the chassis cluster
after the cluster is formed.
1006

Table 76: Chassis Cluster Slot Numbering, and Physical Port and Logical Interface Naming for SRX1400,
SRX3400, and SRX3600

Model Chassis Maximum Slot Management Control Fabric


Slots Per Numbering in Physical Physical Physical
Node a Cluster Port/Logical Port/Logical Port/Logical
Interface Interface Interface

SRX3600 Node 0 13 (CFM 0 — 12 Dedicated Dedicated Any Ethernet


slots) Gigabit Gigabit port
Ethernet port Ethernet port

fxp0 em0 fab0

Node 1 13 — 25 Dedicated Dedicated Any Ethernet


Gigabit Gigabit port
Ethernet port Ethernet port

fxp0 em0 fab1

SRX3400 Node 0 8 (CFM slots) 0—7 Dedicated Dedicated Any Ethernet


Gigabit Gigabit port
Ethernet port Ethernet port

fxp0 em0 fab0

Node 1 8 — 15 Dedicated Dedicated Any Ethernet


Gigabit Gigabit port
Ethernet port Ethernet port

fxp0 em0 fab1

SRX1400 Node 0 4 (FPC slots) 0—3 Dedicated Dedicated Any Ethernet


Gigabit Gigabit port
Ethernet port Ethernet port

fxp0 em0 fab0


1007

Table 76: Chassis Cluster Slot Numbering, and Physical Port and Logical Interface Naming for SRX1400,
SRX3400, and SRX3600 (Continued)

Model Chassis Maximum Slot Management Control Fabric


Slots Per Numbering in Physical Physical Physical
Node a Cluster Port/Logical Port/Logical Port/Logical
Interface Interface Interface

Node 1 4—7 Dedicated Dedicated Any Ethernet


Gigabit Gigabit port
Ethernet port Ethernet port

fxp0 em0 fab1

Information about chassis cluster slot numbering is also provided in Figure 61 on page 1008, Figure 62
on page 1009 and Figure 63 on page 1009.
1008

Figure 61: Chassis Cluster Slot Numbering for SRX3600 Devices


1009

Figure 62: Chassis Cluster Slot Numbering for SRX3400 Devices

Figure 63: Chassis Cluster Slot Numbering for SRX1400 Devices

In a large chassis cluster configuration on an SRX3400 or SRX3600 device, the heartbeat timers are
recommended to increase the wait time to 8 seconds.

You can connect two control links (SRX1400 and SRX3000 lines only) and two fabric links between the
two devices in the cluster to reduce the chance of control link and fabric link failure. See "Understanding
Chassis Cluster Dual Control Links" on page 172 and "Understanding Chassis Cluster Dual Fabric Links"
on page 201.
1010

Figure 66 on page 1011 show pairs of SRX Series Firewalls with the fabric links and control links
connected.

Figure 64 on page 1010 and Figure 65 on page 1010 show pairs of SRX Series Firewalls with the fabric
links and control links connected.

Figure 64: Connecting SRX3600 Devices in a Chassis Cluster

Figure 65: Connecting SRX3400 Devices in a Chassis Cluster

For dual control links on SRX3000 line devices, the Routing Engine must be in slot 0 and the SRX
Clustering Module (SCM) in slot 1. The opposite configuration (SCM in slot 0 and Routing Engine in slot
1) is not supported.
1011

Figure 66: Connecting SRX1400 Devices in a Chassis Cluster

Supported Fabric Interface Types for SRX Series Firewalls (SRX210,


SRX240, SRX220, SRX100, and SRX650 Devices)

For SRX210 devices, the fabric link can be any pair of Gigabit Ethernet interfaces or Fast Ethernet
interfaces (as applicable). Interfaces on SRX210 devices are Fast Ethernet or Gigabit Ethernet (the paired
interfaces must be of a similar type) and all interfaces on SRX100 devices are Fast Ethernet interfaces.

For SRX550 devices, the fabric link can be any pair of Gigabit Ethernet interfaces or Fast Ethernet
interfaces (as applicable).

For SRX Series chassis clusters, the fabric link can be any pair of Ethernet interfaces spanning the
cluster; the fabric link can be any pair of Gigabit Ethernet interface.

Table 77 on page 1011 shows the fabric interface types that are supported for SRX Series Firewalls.

Table 77: Supported Fabric Interface Types for SRX Series Firewalls

SRX550 SRX650 SRX240 SRX220 SRX100 SRX210

Fast Ethernet Fast Ethernet Fast Ethernet Fast Ethernet Fast Ethernet

Gigabit Ethernet Gigabit Ethernet Gigabit Ethernet Gigabit Ethernet Gigabit Ethernet
1012

Redundant Ethernet Interfaces

Table 78: Maximum Number of Redundant Ethernet Interfaces Allowed (SRX100, SRX220, SRX240,
SRX210, and SRX650)

Device Maximum Number of reth Interfaces

SRX100 8

SRX210 8

SRX220 8

SRX240 24

SRX650 68

• Point-to-Point Protocol over Ethernet (PPPoE) over redundant Ethernet (reth) interface is supported
on SRX100, SRX210, SRX220, SRX240, and SRX650 devices in chassis cluster mode. This feature
allows an existing PPPoE session to continue without starting a new PPP0E session in the event of a
failover.

For SRX100, SRX220, and SRX240 devices, the total number of logical interfaces that you can configure
across all the redundant Ethernet (reth) interfaces in a chassis cluster deployment is 1024.

IP address monitoring cannot be used on a chassis cluster running in transparent mode. The maximum
number of monitoring IP addresses that can be configured per cluster is 32 for the SRX1400 device and
the SRX3000 line of devices.

Control Links

• For SRX100, SRX210, and SRX220 devices, the control link uses the fe-0/0/7 interface.

• For SRX210 devices, the total number of logical interfaces that you can configure across all the
redundant Ethernet (reth) interfaces in a chassis cluster deployment is 1024.

• For SRX240, SRX650M, devices, the control link uses the ge-0/0/1 interface.
1013

Table 79: SRX Series Firewalls Interface Settings (SRX100, SRX210, SRX220, SRX240)

Command SRX100 SRX210 SRX220 SRX240

set interfaces fe-0/0/1 ge-0/0/1 ge-0/0/0 to ge-0/0/2


ge-0/0/5
fab0

fabric-options

member-interfaces

set interfaces fe-1/0/1 ge-2/0/1 ge-3/0/0 to ge-5/0/2


ge-3/0/5
fab1

fabric-options

member-interfaces

set chassis cluster fe-0/0/0 weight fe-0/0/3 weight ge-0/0/0 weight 255 ge-0/0/5 weight
redundancy-group 1 255 255 255
interface-monitor

set chassis cluster fe-0/0/2 weight fe-0/0/2 weight ge-3/0/0 weight 255 ge-5/0/5 weight
redundancy-group 1 255 255 255
interface-monitor

set chassis cluster fe-1/0/0 weight fe-2/0/3 weight ge-0/0/1 weight 255 ge-0/0/6 weight
redundancy-group 1 255 255 255
interface-monitor

set chassis cluster fe-1/0/2 weight fe-2/0/2 weight ge-3/0/1 weight 255 ge-5/0/6 weight
redundancy-group 1 255 255 255
interface-monitor

set interfaces fe-0/0/2 fe-0/0/2 ge-0/0/2 fastether- ge-0/0/5 gigether-


fastether-options fastether-options options redundant- options redundant-
redundant-parent redundant-parent parent reth0 parent reth1
reth1 reth1
1014

Table 79: SRX Series Firewalls Interface Settings (SRX100, SRX210, SRX220, SRX240) (Continued)

Command SRX100 SRX210 SRX220 SRX240

set interfaces fe-1/0/2 fe-2/0/2 ge-0/0/3 fastether- ge-5/0/5 gigether-


fastether-options fastether-options options redundant- options redundant-
redundant-parent redundant-parent parent reth1 parent reth1
reth1 reth1

set interfaces fe-0/0/0 fe-0/0/3 ge-3/0/2 fastether- ge-0/0/6 gigether-


fastether-options fastether-options options redundant- options redundant-
redundant-parent redundant-parent parent reth0 parent reth0
reth0 reth0

set interfaces fe-1/0/0 fe-2/0/3 ge-3/0/3 fastether- ge-5/0/6 gigether-


fastether-options fastether-options options redundant- options redundant-
redundant-parent redundant-parent parent reth1 parent reth0
reth0 reth0

ISSU System Requirements for SRX1400, SRX3400 and SRX3600

To perform an ISSU, your device must be running a Junos OS release that supports ISSU for the specific
platform. See Table 80 on page 1014 for platform support.