Pre-Tensioned Cable Stayed Glass Façade System Analysis in STAAD
Pre-Tensioned Cable Stayed Glass Façade System Analysis in STAAD
For a large structure, the architectural display is one of the most vital aspects of a
building’s design, and of nearly equal importance is the building facade.
Structures can boast huge front facades that support glass panels to retain the
aesthetic beauty with minimalistic appearance. These types of buildings may include:
• Shopping malls
• Commercial complexes
• Airport terminals
• Museums
The architect wants a minimum of supporting structures while the engineer wants to
optimize the supporting structures.
To support the huge weight of glass panels and the lateral action due to the wind load,
architects use a conventional method: steel framing systems (Figure 1a), however, they
tend to be bulkier as well as clumsy.
Another technique is to leverage tensile capacity of the “Tension Only” members, like
cable elements.
Since, in general, members have better load bearing capacity when in tension than in
compression (because the compressive buckling effect is absent here), and we can
somehow utilize the members to bear the loads by virtue of their tensile properties, then
we could reduce a significant amount of material. That’s why cable-stayed bridges are
so popular.
The tensioned cable glass façade system (Figure 1b) utilizes the tension bearing
capacity of the cable to bear the gravity as well as the lateral loads the façade
experiences. These cables are pretensioned ̶ just like the strings of a tennis
racquet ̶ to bear the loads.
Figure 1a: Conventional method: steel framing
As a result, these systems are architecturally pleasing. The structural support for the
glass façade uses spider fittings to connect the pieces of glass (Figure 2). The cables
that join the concrete slabs in vertical directions are connected by the prestressed
stainless-steel rods/cables. Specially made steel trusses or struts are connected in-
between and the spider fittings are secured with those trusses. Glass is connected in
the spiders using rotules, and weather sealant is applied between the glass joints.
Combined, it gives a very lightweight look to the glass façade.
Figure 2: Spiders
Using STAAD advanced 3D structural analysis and design software, both the linear and nonlinear
cable analysis options are available.
Linear cable analysis is conducted by using the MEMBER TENSION command in conjunction with
the MEMBER CABLE command. This method works satisfactorily, as long as the cables do not go
into compression, but is not suitable for small deflection.
Nonlinear cable analysis, on the other hand, is the most robust analysis procedure for cable
members. In addition to their ability to handle a nonlinear cable problem, this method also considers
the catenary cable theory (Figure 3b), and so this method is suitable for large complex models
having many interconnected cables.
This nonlinear cable analysis approach is even more rigorous when the stiffness matrix is modified
at every iteration. This is also known as the TANGENT STIFFNESS MATRIX method (Figure 3a).
Fig.3a: Tangent stiffness
Modeling in STAAD
STAAD can handle these kinds of non-linear cable problems very effectively. For example, take the
simple cable net structure in Illustration (Figure 4). These pretensioned cables are running
through the node assembly through its perforation. These nodes are connected to the spider which
holds the faced glass assembly through the rotules.
Figure 4: Pretensioned cable mesh.
We modeled similar projects for a client in STAAD (Figure 5). The cable mesh looks a bit similar.
If you use a normal linear analysis, the program couldn’t effectively consider the nonlinear behavior
of the cable, and so you would produce a high unrealistic displacement leading to an instability
situation.
Figure 7: Linear cable analysis (unstable with high displacement).
We then started using the nonlinear cable analysis with initial tension value of 2.4 KN.
After analysis, the solution couldn't be converged. You can see that the solution is diverging (Figure
8) for the gravity load case. The result is infinitely high displacement against the gravity load.
Figure 8: Nonlinear cable analysis (2.4 KN initial cable tension).
Figure 9: Nonlinear cable analysis (2.4 KN initial cable tension). Infinitely high displacement.
Next we started increasing the initial tension value from 2.4 KN to 24 KN.
This time the solution is converged and so the displacement results are within the realistic limits,
even though they are high at a few nodes. Upon further increasing the initial tension, these
displacement values could be brought to the allowable range.
Figure 10: Nonlinear cable analysis (24 KN initial cable tension).
When running the model with nonlinear cable analysis, the program effectively stabilizes the solution
by providing the actual displacement the facade experiences. At the desired solution, the glass panel
would be hanging firmly to the cable mesh.
Figure 11: Nonlinear cable analysis (24 KN initial cable tension). Stable displacement.