0% found this document useful (0 votes)
54 views4 pages

Bsens: Bushing Sensor

The document discusses a bushing sensor product called BSENS that monitors the condition of transformer bushings. It can detect faults like leakage current, partial discharge, temperature and moisture ingress to prevent bushing failures. The sensor installs on bushing taps and measures parameters like capacitance, dissipation factor and partial discharge signals.

Uploaded by

sunil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
54 views4 pages

Bsens: Bushing Sensor

The document discusses a bushing sensor product called BSENS that monitors the condition of transformer bushings. It can detect faults like leakage current, partial discharge, temperature and moisture ingress to prevent bushing failures. The sensor installs on bushing taps and measures parameters like capacitance, dissipation factor and partial discharge signals.

Uploaded by

sunil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

MONITORING SIMPLIFIED

BSENS
Bushing Sensor
Improved Transformer durability
with evident performance of bushings

Robust | Reliable | Responsive


BSENS Bushing Sensor for Improved Transformer Reliability
to Avoid Bushing Failure

Bushing failures can be caused by transient overvoltage’s,


temperature fluctuations, as well as by the ingress of
moisture, which can quickly lead to failure of bushing
insulation or even to a major transformer failure.

Our BSENS continually perform online condition monitoring of transformer bushings through regular
time-based diagnostics. Bushing adaptors are installed at the bushing test tap or voltage tap. Being
a function of phase ground voltage and impedance of the bushing insulation, leakage current passes
through the tap adaptors flowing to ground through capacitance, any imbalance in the impedance of
the insulation will lead to variation in leakage current.
The measured leakage current from BSENS provides following outputs:
Capacitance
Tan δ or Dissipation Factor
Partial Discharge Signals
Bushing Sensors for Tan δ and Capacitance monitoring are based on measuring Leakage Current in
the range of 1mA to 200mA which also additionally provides HF signals between 100 kHz – 25 MHz
for PD monitoring.
We at Rugged Monitoring have 45+ different bushing tap adaptors designed to cover most of the
bushings aiding in faster system commissioning. Our standard sensors are designed for bushings
with rated voltage of upto 1500 kV.

Benefits
Easy installation and commissioning
Flexible configuration options to meet customer expectations
Generates highly accurate data
Early incipient fault detection ensures reliable operation and
reduces supply outages

Applications
Condensing/ capacitive type bushings

Transformer Bushings

Breaker Bushings

01
BSENS
Features
Reliable and robust product Based on industry standard method
Measures leakage currents of fundamental Most accurate condition analysis
harmonics Custom designed for various bushing taps
Variants are available for monitoring up to 6
bushings on three phase transformers
It measures High Frequency PD signals

Technical Specifications
Transient Voltage Protection Up to 1500 KV Bushings

Bushing Tap Earthing Protection Double Protection against any loss to grounding connection
Leakage Current = 1mA to 200mA
ELECTRICAL Sensor Output
Partial Discharge: 100 kHz to 25 MHz
SPECIFICATIONS
Recommended Cable RG213 or RG58

Measured Parameters Leakage Current and Partial Discharge


MECHANICAL
Custom designed for various bushing taps
SPECIFICATIONS

Operating Temperature -60°C to +95°C

ENVIRONMENTAL Storage Temperature -40°C to +85°C


SPECIFICATIONS Humidity 95% Relative Humidity

IP rating IP 66 (Protection against moisture ingress)

Ordering Code
BUSHING SENSOR- LEAKAGE CURRENT BUSHING SENSOR- PARTIAL DISCHARGE

Bushing Sensor Bushing Model Sensor Material Bushing Sensor Bushing Model Sensor Material
(e.g., GOH, ALMO) 1. Aluminium (e.g., GOH, ALMO) 1. Aluminium
2. Stainless Steel 2. Stainless Steel

B S E N S - L z - y y y y - x w B S E N S - P z - y y y y - x w

Leakage Current Partial Discharge


Model of Sensor Sensor Connector Model of Sensor Sensor Connector
z= 0 to 9 0 = TNC z= 0 to 9 0 = TNC
1 = BNC 1 = BNC
2 = N Type 2 = N Type
DS0009R04_BSENS_EN_A4

02
Our Presence Across the Globe

Head Office
Canada
1415 Frank-Carrel, Suite
230, Quebec, QC - G1N
4N7, CANADA
+1-418-767-0111

Asia Pasific India Europe Latin America Middle East North America

Rugged Monitoring Services About Rugged Monitoring

Rugged Monitoring provides customization of Industry’s leading team of asset condition


sensors, monitors & software. In addition we monitoring experts with 100+ years of
offer on-site commissioning services, combined experience committed to delivering
maintenance contracts and technical support to customizable solutions for challenging
all customers worldwide. applications. We offer a range of reliable, high
performance, customizable sensors and
monitoring solutions that are immune to
external influence.

ruggedmon ©2021 Rugged Monitoring Company. All rights


reserved. Information subject to change
[email protected]
without notice. All trademarks are properties of
www.ruggedmonitoring.com their respective companies, as noted herein.