0% found this document useful (0 votes)
49 views2 pages

Tds 0005

This module has been designed by Dynament to provide OEM developers with hardware and software to drive infrared gas sensors and convert sensor signals into a linearised 4-20mA analogue output proportional to gas concentration. It requires only a single 8-30V power supply. The module has a compact design, 12-bit A/D converter, regulated sensor lamp drive, pushbutton interface, and optional mounting accessories. It offers engineers a quick route to incorporate infrared gas sensing into their products.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
49 views2 pages

Tds 0005

This module has been designed by Dynament to provide OEM developers with hardware and software to drive infrared gas sensors and convert sensor signals into a linearised 4-20mA analogue output proportional to gas concentration. It requires only a single 8-30V power supply. The module has a compact design, 12-bit A/D converter, regulated sensor lamp drive, pushbutton interface, and optional mounting accessories. It offers engineers a quick route to incorporate infrared gas sensing into their products.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Technical data

sheet TDS0005

OEM MODULE TYPE OEM-1


FOR USE WITH THE “STANDARD”
RANGE OF INFRARED GAS SENSORS

For operating
instructions, please refer
to data sheet TDS 0008

This module has been designed by Dynament to provide OEM development engineers with a fast track route to market
utilising the Gold Series range of infrared sensors. Requiring only a dc power supply, the module provides all the hardware and
embedded software necessary to drive the sensor, extract the signals and convert them into a linearised analogue output
proportional to gas concentration.

FEATURES
♦ Compact design for use within standard explosion proof enclosures ( pcb dia. 78mm, 3.1 in.)
♦ Quickest route into the Infrared market
♦ High resolution 12 bit A-D converter
♦ Regulated lamp drive circuit
♦ Pushbutton operation and onboard LCD for simple set-up and calibration only
♦ 4-20mA analogue output, 10 bit, with current limit and polarity protection
♦ Data collection mode and RS232 data output facility remote monitoring and data logging
♦ Polarity protected input for single 8-30V, 70mA dc supply
♦ Optional sensor mounting and gas sampling adaptor

DESCRIPTION OF OPERATION

The circuitry provides a regulated, 4Hz. square-wave drive to the sensor’s lamp. The resulting signals from the sensor’s
Detector and Reference outputs are amplified to a suitable level and processed by the A/D converter. Using the program
appropriate to the type of sensor selected by the user, the microcontroller uses the signals from the sensor to provide a
linearised drive to the analogue output circuit.
In order to calibrate the OEM module, it is necessary to present a “zero” gas sample and a “span” gas sample to the sensor.
There are 4 pushbuttons and a 4 digit display on the OEM module. These enable the user to select from the following options:

♦ Sensor type select i.e. Carbon Dioxide, Methane etc.


♦ Sensor zero mode
♦ Sensor span mode
♦ Analogue Output zero mode
♦ Analogue Output span mode
♦ Run mode
♦ Data observation mode

The on-board display is for set-up and calibration only. When module is used in an instrument, a separate display is required.
(See ‘Typical Application’ overleaf).

TDS 0005 Issue 3.2 12/09/16 Change Note 543 Page 1 of 2


MODULE BLOCK DIAGRAM

Polarity
protected POWER
IR Sensor PSU INPUT
Lamp Drive

Micro controller Liquid crystal


Pushbuttons Current
display
Limit

Detector Amplifier
Digital to
Infrared Analogue Analogue ANALOGUE
Sensor Converter Output OUTPUT
Analogue to (10-bit) (4-20mA
Reference Amplifier Digital Source)
Converter
Temperature (12-bit) RS232 Tx
Interface Rx
OV

TYPICAL APPLICATION

OEM-1 MODULE
LOOP POWERED METER
REAR VIEW FRONT VIEW (NOT PROVIDED)

A = 50mm (1.97”) DISPLAY FOR


B = 78mm (3.07”)
C = 3.5mm (0.138”)
CALIBRATION
PURPOSES ONLY 0000
4-20mA
PC LOOP
0000
A

POWER
SENSOR MOUNTING
SUPPLY
SENSOR A (NOT PROVIDED)
CABLE C
B

ADAPTOR

ORDERING INFORMATION
ITEM DYNAMENT PART NUMBER
OEM MODULE OEM - 1
SENSOR CABLE AND CONNECTOR OEM – 1-CABLE (130mm, 5.1”)
(Supplied free of charge when sensor and REFER TO DATA SHEET TDS 0009 FOR
OEM Module are ordered together) FURTHER DETAILS ON THESE ITEMS

SENSOR MOUNTING OEM – 1- MTG


GAS SAMPLING ADAPTOR OEM – 1- ADTR
NOTE: INFRARED SENSORS ARE SUPPLIED SEPARATELY, REFER TO SENSOR DATA SHEETS FOR ORDERING INFORMATION

Dynament Limited
Hermitage Lane Industrial Estate ٠ Kings Mill Way ٠ Mansfield ٠ Nottinghamshire ٠ NG18 5ER ٠ UK.
Tel: 44 (0)1623 663636 ٠ Fax: 44 (0)1623 421063
email: [email protected] ٠ www.dynament.com

TDS 0005 Issue 3.2 12/09/16 Change Note 543 Page 2 of 2