0% found this document useful (0 votes)
20 views4 pages

Design of Column: Summery Load-KN SIZE

The document provides design details for 7 columns (C1-C7). It specifies the load, size, reinforcement, and checks calculations for each column. The load ranges from 150kN to 1070kN. Column sizes range from 200x300mm to 200x900mm. Reinforcement varies from 6 bars of 6mm diameter to 16 bars of 14mm diameter. Reinforcement area calculations and checks are provided for each column design.

Uploaded by

Yousif R. Alj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views4 pages

Design of Column: Summery Load-KN SIZE

The document provides design details for 7 columns (C1-C7). It specifies the load, size, reinforcement, and checks calculations for each column. The load ranges from 150kN to 1070kN. Column sizes range from 200x300mm to 200x900mm. Reinforcement varies from 6 bars of 6mm diameter to 16 bars of 14mm diameter. Reinforcement area calculations and checks are provided for each column design.

Uploaded by

Yousif R. Alj
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

DESIGN OF COLUMN COL.

N0:- C1 1

Load on a column P= 520 KN SUMMERY


Width of column b= 200 mm LOAD- 520 KN
Depth of column D= 400 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 400
Hence column can be designed as a short one with axial load BAR:- 6 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 80000 sqmm
Ultimate load on column 1.5xP Pu= 780 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 454 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 320 sqmm
PROVIDE 6 6Y14BAR
MAIN BARS
14 Asc(pro) = 923 sqmm
AREA PROVIDED OK
DESIGN OF COLUMN COL. N0:- C2
Load on a column P= 660 KN SUMMERY
Width of column b= 200 mm LOAD- 660 KN
Depth of column D= 500 mm SIZE:-
Column clear height between end restraints,Lo = 2700 mm
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 500
Hence column can be designed as a short one with axial load BAR:- 8 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 100000 sqmm
Ultimate load on column 1.5xP Pu= 990 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 616 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 400 sqmm
PROVIDE 6 8Y14BAR
MAIN BARS
14 Asc(pro) = 1231 sqmm
AREA PROVIDED OK

DESIGN OF COLUMN COL. N0:- C3 2

Load on a column P= 800 KN SUMMERY


Width of column b= 200 mm LOAD- 800 KN
Depth of column D= 600 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 600
Hence column can be designed as a short one with axial load BAR:- 10 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 120000 sqmm
Ultimate load on column 1.5xP Pu= 1200 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 779 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 480 sqmm
PROVIDE 6 10Y14BAR MAIN BARS
14 Asc(pro) = 1539 sqmm
AREA PROVIDED OK
DESIGN OF COLUMN COL. N0:- C4 2

Load on a column P= 930 KN SUMMERY


Width of column b= 200 mm LOAD- 930 KN
Depth of column D= 700 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 700
Hence column can be designed as a short one with axial load BAR:- 12 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 140000 sqmm
Ultimate load on column 1.5xP Pu= 1395 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 892 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 560 sqmm
PROVIDE 6 12Y14BAR MAIN BARS
14 Asc(pro) = 1846 sqmm
DESIGN OF COLUMN COL. N0:- C5 2

Load on a column P= 1070 KN SUMMERY


Width of column b= 200 mm LOAD- 1070 KN
Depth of column D= 800 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 800
Hence column can be designed as a short one with axial load BAR:- 14 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 160000 sqmm
Ultimate load on column 1.5xP Pu= 1605 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 1055 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 640 sqmm
PROVIDE 6 14Y14BAR MAIN BARS
14 Asc(pro) = 2154 sqmm
DESIGN OF COLUMN COL. N0:- C6 2

Load on a column P= 1070 KN SUMMERY


Width of column b= 200 mm LOAD- 1070 KN
Depth of column D= 900 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 900
Hence column can be designed as a short one with axial load BAR:- 16 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 180000 sqmm
Ultimate load on column 1.5xP Pu= 1605 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 535 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 720 sqmm
PROVIDE 6 16Y14BAR MAIN BARS
14 Asc(pro) = 2462 sqmm
DESIGN OF COLUMN COL. N0:- C7 2

Load on a column P= 150 KN SUMMERY


Width of column b= 200 mm LOAD- 150 KN
Depth of column D= 300 mm SIZE:-
Column clear height between end restraints,Lo = 2700
Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo
Assumed value of k for braced short column = 0.8
Effective length of column Leff= 2160 mm WIDTH:- 200
Ratio Leff / b = 10.8 <15 DEPTH:- 300
Hence column can be designed as a short one with axial load BAR:- 6 14
Charecteristic strength of reinfo. fy= 460 N/mm2
Carecteristic strength of concrete fck= 20 N/mm2
Area of concrete Ac= b x D Ac= 60000 sqmm
Ultimate load on column 1.5xP Pu= 225 KN
Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:-
Pu = 0.4*fck*Ac +0.67*fy*Asc
Area of longitudinal steel required,Asc as per the above equation;
Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= -827 sqmm
check for min. reinforcement
Asc (min.) = 0.004*b*D/100 Asc(min) = 240 sqmm
PROVIDE 6 6Y14BAR
MAIN BARS
14 Asc(pro) = 923 sqmm

You might also like