The document provides design details for 7 columns (C1-C7). It specifies the load, size, reinforcement, and checks calculations for each column. The load ranges from 150kN to 1070kN. Column sizes range from 200x300mm to 200x900mm. Reinforcement varies from 6 bars of 6mm diameter to 16 bars of 14mm diameter. Reinforcement area calculations and checks are provided for each column design.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
20 views4 pages
Design of Column: Summery Load-KN SIZE
The document provides design details for 7 columns (C1-C7). It specifies the load, size, reinforcement, and checks calculations for each column. The load ranges from 150kN to 1070kN. Column sizes range from 200x300mm to 200x900mm. Reinforcement varies from 6 bars of 6mm diameter to 16 bars of 14mm diameter. Reinforcement area calculations and checks are provided for each column design.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4
DESIGN OF COLUMN COL.
N0:- C1 1
Load on a column P= 520 KN SUMMERY
Width of column b= 200 mm LOAD- 520 KN Depth of column D= 400 mm SIZE:- Column clear height between end restraints,Lo = 2700 Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo Assumed value of k for braced short column = 0.8 Effective length of column Leff= 2160 mm WIDTH:- 200 Ratio Leff / b = 10.8 <15 DEPTH:- 400 Hence column can be designed as a short one with axial load BAR:- 6 14 Charecteristic strength of reinfo. fy= 460 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 80000 sqmm Ultimate load on column 1.5xP Pu= 780 KN Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:- Pu = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required,Asc as per the above equation; Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 454 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 320 sqmm PROVIDE 6 6Y14BAR MAIN BARS 14 Asc(pro) = 923 sqmm AREA PROVIDED OK DESIGN OF COLUMN COL. N0:- C2 Load on a column P= 660 KN SUMMERY Width of column b= 200 mm LOAD- 660 KN Depth of column D= 500 mm SIZE:- Column clear height between end restraints,Lo = 2700 mm Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo Assumed value of k for braced short column = 0.8 Effective length of column Leff= 2160 mm WIDTH:- 200 Ratio Leff / b = 10.8 <15 DEPTH:- 500 Hence column can be designed as a short one with axial load BAR:- 8 14 Charecteristic strength of reinfo. fy= 460 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 100000 sqmm Ultimate load on column 1.5xP Pu= 990 KN Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:- Pu = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required,Asc as per the above equation; Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 616 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 400 sqmm PROVIDE 6 8Y14BAR MAIN BARS 14 Asc(pro) = 1231 sqmm AREA PROVIDED OK
DESIGN OF COLUMN COL. N0:- C3 2
Load on a column P= 800 KN SUMMERY
Width of column b= 200 mm LOAD- 800 KN Depth of column D= 600 mm SIZE:- Column clear height between end restraints,Lo = 2700 Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo Assumed value of k for braced short column = 0.8 Effective length of column Leff= 2160 mm WIDTH:- 200 Ratio Leff / b = 10.8 <15 DEPTH:- 600 Hence column can be designed as a short one with axial load BAR:- 10 14 Charecteristic strength of reinfo. fy= 460 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 120000 sqmm Ultimate load on column 1.5xP Pu= 1200 KN Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:- Pu = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required,Asc as per the above equation; Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 779 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 480 sqmm PROVIDE 6 10Y14BAR MAIN BARS 14 Asc(pro) = 1539 sqmm AREA PROVIDED OK DESIGN OF COLUMN COL. N0:- C4 2
Load on a column P= 930 KN SUMMERY
Width of column b= 200 mm LOAD- 930 KN Depth of column D= 700 mm SIZE:- Column clear height between end restraints,Lo = 2700 Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo Assumed value of k for braced short column = 0.8 Effective length of column Leff= 2160 mm WIDTH:- 200 Ratio Leff / b = 10.8 <15 DEPTH:- 700 Hence column can be designed as a short one with axial load BAR:- 12 14 Charecteristic strength of reinfo. fy= 460 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 140000 sqmm Ultimate load on column 1.5xP Pu= 1395 KN Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:- Pu = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required,Asc as per the above equation; Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 892 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 560 sqmm PROVIDE 6 12Y14BAR MAIN BARS 14 Asc(pro) = 1846 sqmm DESIGN OF COLUMN COL. N0:- C5 2
Load on a column P= 1070 KN SUMMERY
Width of column b= 200 mm LOAD- 1070 KN Depth of column D= 800 mm SIZE:- Column clear height between end restraints,Lo = 2700 Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo Assumed value of k for braced short column = 0.8 Effective length of column Leff= 2160 mm WIDTH:- 200 Ratio Leff / b = 10.8 <15 DEPTH:- 800 Hence column can be designed as a short one with axial load BAR:- 14 14 Charecteristic strength of reinfo. fy= 460 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 160000 sqmm Ultimate load on column 1.5xP Pu= 1605 KN Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:- Pu = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required,Asc as per the above equation; Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 1055 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 640 sqmm PROVIDE 6 14Y14BAR MAIN BARS 14 Asc(pro) = 2154 sqmm DESIGN OF COLUMN COL. N0:- C6 2
Load on a column P= 1070 KN SUMMERY
Width of column b= 200 mm LOAD- 1070 KN Depth of column D= 900 mm SIZE:- Column clear height between end restraints,Lo = 2700 Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo Assumed value of k for braced short column = 0.8 Effective length of column Leff= 2160 mm WIDTH:- 200 Ratio Leff / b = 10.8 <15 DEPTH:- 900 Hence column can be designed as a short one with axial load BAR:- 16 14 Charecteristic strength of reinfo. fy= 460 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 180000 sqmm Ultimate load on column 1.5xP Pu= 1605 KN Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:- Pu = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required,Asc as per the above equation; Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= 535 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 720 sqmm PROVIDE 6 16Y14BAR MAIN BARS 14 Asc(pro) = 2462 sqmm DESIGN OF COLUMN COL. N0:- C7 2
Load on a column P= 150 KN SUMMERY
Width of column b= 200 mm LOAD- 150 KN Depth of column D= 300 mm SIZE:- Column clear height between end restraints,Lo = 2700 Effective length of column(as per Bscode: clause: 3.8.1.6) = kLo Assumed value of k for braced short column = 0.8 Effective length of column Leff= 2160 mm WIDTH:- 200 Ratio Leff / b = 10.8 <15 DEPTH:- 300 Hence column can be designed as a short one with axial load BAR:- 6 14 Charecteristic strength of reinfo. fy= 460 N/mm2 Carecteristic strength of concrete fck= 20 N/mm2 Area of concrete Ac= b x D Ac= 60000 sqmm Ultimate load on column 1.5xP Pu= 225 KN Design ultimate axial load for a short column(as per BS: cl:3.8.4.4) is gives as:- Pu = 0.4*fck*Ac +0.67*fy*Asc Area of longitudinal steel required,Asc as per the above equation; Asc= (Pu - 0.4*fck*Ac)/ (0.67*fy) Asc= -827 sqmm check for min. reinforcement Asc (min.) = 0.004*b*D/100 Asc(min) = 240 sqmm PROVIDE 6 6Y14BAR MAIN BARS 14 Asc(pro) = 923 sqmm