Sheet Pile Design Calculation
Sheet Pile Design Calculation
a'= 2 m
b'= 1 m
Surcharge Load, q= 40 kN/m2 (Strip Loading)
H= 6 m
Ө1 9.462322 DEGREES
Ө2 26.56505 DEGREES
Total Force per unit length due to strip loading , P= 45.60728 kN/m
3.125092 k/ft
TOTAL ACTIVE PRESSURE DUE TO SOIL WEIGHT & SURCHARGE LOAD CALCULATION
(Strip Loading)
CALCULATION
40(SI unit) & 12(fps unit)
3 (for cohesive soil) & 2(for cohesion soil)
d at several depths in the likely range of pile embedment depth D and q ult= qa*SF)