Sunysytem SWPN 300 Manual Tanc Apa
Sunysytem SWPN 300 Manual Tanc Apa
SWP 2N
with two coils
SWP N
with one coil
SWP NL
with one coil
Version 0.3.3
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and OPERATION
ИНСТРУКЦИЯ MANUAL
за МОНТАЖ и ЕКСПЛОАТАЦИЯ
2
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
TABLE OF CONTENTS
1. INSTRUCTIONS TO INSTALLER............................................................................... 4
1.1. Requirements to water tank installation room...................................................... 4
1.2. Requirements for installation. ............................................................................... 4
2. DESCRIPTION ON SWP........................................................................................... 5
4. TECHNICAL PARAMETERS.................................................................................... 14
4.1. SWP NL - with one coil...........................................................................................14
4.2. SWP N - with one coil............................................................................................16
4.3. SWP 2N - with two coils........................................................................................18
6. WARRANTY ..........................................................................................................20
7. RECYCLING........................................................................................................... 23
3
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and OPERATION
ИНСТРУКЦИЯ MANUAL
за МОНТАЖ и ЕКСПЛОАТАЦИЯ
protective equipment
and commissioning must be
performed by an authorized - Before commissioning, check the
installer / service. installation for leaks
- Do not exceed the working pressure of 3
During installation and operation, the bar for buffer tank and 6 bar for hygienic
country specific requirements and stainless steel coil.
regulations must be observed:
• local construction regulations on - If there is a risk of freezing of water in
installation of water tank; weight of the the tank - drain the tank completely or let
boiler to comply with the stability of the the water tank works continuously.
floor of the room where it will be installed.
• regulations and norms concerning
the fitting of theinstallation with safety
devices.
• safety during installation - personal
4
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
electricians.
When connect the heating element
to the electric network, make sure
that it is properly grounded.
Wiring diagrams
6
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
2.4. Thermometer
7
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and OPERATION
ИНСТРУКЦИЯ MANUAL
за МОНТАЖ и ЕКСПЛОАТАЦИЯ
8
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
2.7.Thermostat (option).
sheme 1
The thermostat may be adjusted by the TECHNICAL CHARACTERISTICS
user within the range 30°С ÷ 80°С, and the Temperature range – regulation- 0°C ÷
thermal protection would go off in case 90°C;
the water reaches 95°С. limit - 90°C ÷ 110°C;
This is an adjustable double THERMOSTAT Tolerance
Regulation ± 5k,
which is designed to regulate the water
temperature and ensures safety tolerance; limit – 15 k; -6 k (depends on the type)
it can be manually adjusted (TLSC model)
or automatically adjusted (TLSC/A model). Temperature differential
Regulation 6 ± 2 k; 4 ± 1 k (depends
on the type)
Limit 25 ± 8 k; 15 ± 8 k (depends on
the type)
C-1LIM.:0,5A/250V~;
C2LIM.:10(2,5)A/250V~;
Terminal – circuit breaker or
switch-on contacts.
Switch-on action – 2B.
Place of installation – normal.
Type of wire – M20 x 1.5.
WARNING !
All installation operations,
including manual adjustments,
must be fulfilled by a qualified sheme 4
specialist following all safety
conditions.
b)Unscrew the three bolts and remove
the front part of the thermostat. Unravel
INSTALLATION AND CONNECTION . the power supply wires and connect them
Safety instructions: to the terminals of the thermostat
(Figure 5) following the instructions.
Before connecting the thermostat, make
sure that THE UNIT TO BE THERMALLY
CONTROLLED (water heater, pump, etc.)
IS NOT CONNECTED to the power supply
network, and is in compliance with the
instructions in Figure
sheme 5
sheme 2
а) ) See scheme 3 and scheme 4.
sheme 3 sheme 6
10
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
LIMITATION
TERMINAL 2 – opens the circuit when the
temperature
rises.
TERMINAL C – common contact.
THERMOSTAT
TERMINAL 1 – opens the circuit when the
temperature rises.
TERMINAL 2 – closes the circuit when
the temperature rises
TERMINAL C – common contact
sheme 8
11
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and OPERATION
ИНСТРУКЦИЯ MANUAL
за МОНТАЖ и ЕКСПЛОАТАЦИЯ
safety (relief) valve and the tank.
It is recommended once a year to
check the operation of the safety
valve.
12
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
13
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and OPERATION
ИНСТРУКЦИЯ MANUAL
за МОНТАЖ и ЕКСПЛОАТАЦИЯ
14
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
Insulation 50 mm rigid PU
Sleeve for Electric element on inspection opening flange Uo,mm, Rp11/2” 298 345 345
16
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
Insulation 50 mm rigid PU
Cold water inlet A, mm Rp1”/182 Rp1”/182 Rp1”/215 Rp11/4 “/270 Rp11/2” /270
Hot water outlet B, mm Rp1”/895 Rp1”/1160 Rp1”/1182 Rp11/4 ”/1240 Rp11/2” /1453
Inlet/Outlet Lower coi S1 S1i/ S1o, 872/182 1122/182 1155/215 1210/270 1350/270
mm,Rp1”
Prolonged power acc. to DIN 4708; kW (m3/h) 40.4(0.99) 51(1.25) 62(1.52) 75(1.84) 84(2.06)
10°C/80°C/45°C, S1
Pressure drop Δp, S1 Δp, mbar 120 150 400 600 710
Sleeve for Electric element Uo,mm, Rp11/2” 309 309 320 450 450
on inspection opening flange
Air vent sleeve F, mm, Rp1” 1070 1340 1410 1460 1710
Sensor sleeve for thermostat G, mm, Rp1/2” 697 967 1054 1054 1206
17
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and OPERATION
ИНСТРУКЦИЯ MANUAL
за МОНТАЖ и ЕКСПЛОАТАЦИЯ
18
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and за
ИНСТРУКЦИЯ OPERATION MANUAL
МОНТАЖ и ЕКСПЛОАТАЦИЯ
Insulation 50 mm rigid PU
Sleeve for Electric element on inspection opening flange Uo,mm, Rp11/2” 545 620 666
19
INSTALLATION
ТЕХНИЧЕСКИ ПАСПОРТ. and OPERATION
ИНСТРУКЦИЯ MANUAL
за МОНТАЖ и ЕКСПЛОАТАЦИЯ
6. WARRANTY
5) Freeze, flood, natural disasters or third For this purpose the claimant shall fill out
party actions as well as any interventions a claim form; the latter shall be accompa-
into normal functioning conditions of wa- nied by the document proving the pur-
ter heaters and the control of NES Ltd. chase of the water heater (invoice) with
The customer as well should monitor the the date of purchase in it.
anticorrosion system (magnesium anodе).
He should periodically check the mag- b) After receiving the claim form, NES Ltd.
nesium anode and replace it depending considers it and makes decision whether
on the geographic location at intervals the claim has grounds, and whether the
depending on the type of water (soft of defect is within the scope of the warranty
hard) of the region where the water heat- set forth in this certificate for limited war-
er is being used. ranty; after which informs the customer
as to its decision and the steps he shall do.
b) The warranty certificate is considered
void for water heaters whose serial iden- c) The return of a product cannot be done
tification number has been modified, re- without written authorization issued by
moved or blurred, or cannot be expressly the Quality Department. The return pro-
attested. cedure shall be according to RMA (Return
c) Damages in the appearance of products Material Authorization).
shall not be considered as defects except
for those ones which cause losses during d) If on customer’s request, and when
operation or change technical character- there is reason for urgency, the customer
istics of water heaters set forth in bro- demands immediate replacement of the
chures. product he has claimed warranty for, be-
d) NES Ltd. preserves the right, in case of fore making the decision as to the claim,
replacement, to deliver another model of said request shall be accompanied by a
water heater in order to fulfill approved Purchase requisition from the Commer-
warranty claims when the original model cial Department. After decision for satis-
is not being manufactured. faction of the claim has been made, the
Purchase requisition mentioned above
6.3. Claiming warranty will be annulled by issuing a receipt for
Every customer who has purchased a wa- returned goods; with this receipt the
ter heater from NES Ltd., and who has customer can purchase another product
good reasons to lay a warranty claim, shall with the same price in case the claim has
proceed as follows: proved grounded.
23
ISO 9001
BUREAU VERITAS
Certification