The document contains heat transfer calculations for three different heat exchanger scenarios. It includes parameters like temperature, heat transfer rate, area, tube dimensions, fluid properties and heat transfer coefficients for both the tube and shell sides.

Uploaded by

roaanaseem267
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views

Book 1

The document contains heat transfer calculations for three different heat exchanger scenarios. It includes parameters like temperature, heat transfer rate, area, tube dimensions, fluid properties and heat transfer coefficients for both the tube and shell sides.

Uploaded by

roaanaseem267
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 6

T need to cool

t need to heat

H.1 R (m3.Pa/mol.K)
T1 T2
673.00 403.00
∆Tlm 143.95
∆Tm 115.16
Q (kW) 2506.60

tube side
MW 31.50
D○ (m) 0.00630
L tot (m) 12781.42
L tube (m) 4.88
# of tube 2620.86
BWG 12.00
Di (m) 0.004
1 in ∆
Ac 0.000015
ρ (kg/m3) 391.00
µ (Cp) 0.40
v (m/s) 1.62
Re 6805
k (W/m.K) 0.18
Pr 188.89
hi (W/m2k) 6434.36
8.31 P tube (kPa 5000.00 P shell (kPa 5000.00
t1 t2 R P
309.55 463.00 1.76 0.42
f (ref plant 0.80 T avg 538.00
t avg 386.28
U (W/m2k) 86.01 H.T area A (m2) 253.07

shell side U calculation


MW 18.00 Do/Di 1.4651
0.0126 shell ID (m 2.00 1/hi 0.0002
A shell 0.51 1/hi*do/di 0.0002
ρ (kg/m3) 2.20 1/ho 0.0011
µ (Cp) 0.170 1/hod 0.0001
v (m/s) 4.19 1/hid 0.0001
Re 341.41 1/hid*do/d 0.0001
k 0.30
Pr 19.83 Kw 5.0000
ho (W/m2k 880.25 ln(do/di) 0.3819
hid 20000.00 do*ln/Kw 0.0101
hod 20000.00 1/U 0.0116
U 86.01

∆U 0.000 0.00
T need to cool
t need to heat

H.1 R (m3.Pa/m 8.31 P tube (kPa 1000.00 P shell (kPa 100.00


T1 T2 t1 t2 R P
635.00 350.00 293.00 363.00 4.07 0.20
∆Tlm 137.58 f (ref plant 0.73 T avg 492.50
∆Tm 100.43 t avg 328.00
Q (kW) 4742.27 U (W/m2k) 747.64 H.T area A (m2) 63.16

tube side shell side U calculation


MW 31.50 MW 18.00 Do/Di 1.1176
D○ (m) 0.01900 0.0380 shell ID (m 0.40 1/hi 0.0004
L tot (m) 1057.65 0.00950 A shell 0.02 1/hi*do/di 0.0005
L tube (m) 4.88 ρ (kg/m3) 984.00 1/ho 0.0001
# of tube 216.87 µ (Cp) 0.500 1/hod 0.0000
BWG 12.00 v (m/s) 0.92 1/hid 0.0000
Di (m) 0.017 Re 34229.62 1/hid*do/d 0.0000
1 in ∆ k 0.65
Ac 0.000227 Pr 26.92 Kw 1.0400
ρ (kg/m3) 49.00 ho (W/m2k 11114.84 ln(do/di) 0.1112
µ (Cp) 0.02 hid 60000.00 do*ln/Kw 0.0007
v (m/s) 2.50 hod 60000.00 1/U 0.0013
Re 115553 U 747.64
k (W/m.K) 0.05
Pr 31.28 ∆U 0.000
hi (W/m2k) 2392.85 375-750
0.02375

0.00
t need to heat

H.1 R (m3.Pa/m 8.31 P tube (kPa 1000.00 P shell (kPa 100.00


T1 T2 t1 t2 R P
404.80 362.00 293.00 343.00 0.86 0.45
∆Tlm 65.33 f (ref plant 0.89 T avg 383.40
∆Tm 58.15 t avg 318.00
Q (kW) 494.40 U (W/m2k) 558.53 H.T area A (m2) 15.22

tube side shell side U calculation


MW 23.25 MW 18.00 Do/Di 1.0855
0.129917 D○ (m) 0.02540 0.0508 shell ID (m 0.21 1/hi 0.0001
L tot (m) 190.70 0.01270 A shell 0.004 1/hi*do/di 0.0001
0.03175 L tube (m) 4.88 0.0127 ρ (kg/m3) 992.00 1/ho 0.0001
# of tube 39.10 µ (Cp) 0.590 1/hod 0.0000
BWG 12.00 v (m/s) 0.53 1/hid 0.0000
Di (m) 0.023 Re 22843.31 1/hid*do/d 0.0000
1 in ∆ k 0.64
Ac 0.000430 Pr 32.27 Kw 1.0600
ρ (kg/m3) 443.00 ho (W/m2k 6821.96 ln(do/di) 0.0820
µ (Cp) 0.29 hid 60000.00 do*ln/Kw 0.0015
v (m/s) 1.19 hod 60000.00 1/U 0.0018
Re 42661 U 558.53
k (W/m.K) 0.42
Pr 65.35 ∆U 0.000
hi (W/m2k) 8411.22 375-750