Model No.: D4: 4 Channel Constant Voltage DMX512 & RDM Decoder

This document summarizes a 4 channel constant voltage DMX512 & RDM decoder. It has digital numeric display, supports RDM communication with DMX masters, provides 1/2/4 DMX channel output selection, PWM frequency selection from 250-16000Hz, and linear or logarithmic dimming. It has overheat, overload, and short circuit protections, and comes in white or black with a 5 year warranty.

Uploaded by

justfanlove
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views

Model No.: D4: 4 Channel Constant Voltage DMX512 & RDM Decoder

This document summarizes a 4 channel constant voltage DMX512 & RDM decoder. It has digital numeric display, supports RDM communication with DMX masters, provides 1/2/4 DMX channel output selection, PWM frequency selection from 250-16000Hz, and linear or logarithmic dimming. It has overheat, overload, and short circuit protections, and comes in white or black with a 5 year warranty.

Uploaded by

justfanlove
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

4 Channel Constant Voltage DMX512 & RDM Decoder

Model No.: D4
RDM/Stand-alone function/Seven PWM frequency/Linear or logarithmic dimming/Numeric display/Din Rail/Multiple protection

Features
● Comply with the DMX512 standard protocols.
● Digital numeric display, set DMX decode start address by buttons.
● RDM function can realize intercommunication between DMX master and decoder.
For example, DMX decoder address can be set by DMX master console.
● 1/2/4 DMX channel output selectable.
● 16bit (65536 levels) /8bit (256 levels) grey level selectable.
● PWM frequency 250/500/1000/2000/4000/8000/16000Hz selectable.
● Logarithmic or linear dimming curve selectable.
● Stand-alone RGB/RGBW mode and 4 channel dimmer mode selectable,
which be controlled by buttons with built-in programs, instead of DMX signal.
● Over-heat / Over-load / Short circuit protection, recover automatically.
● Available in white or black. LVD

Technical Parameters
Input and Output Safety and EMC Warranty and Protection
Input voltage 12-24VDC ETSI EN 301 489-1 V2.2.3 Warranty 5 years
EMC standard (EMC)
Input current 20.5A ETSI EN 301 489-17 V3.2.4 Reverse Polarity
Over-heat (>95°C start)
Output voltage 4 x (12-24)VDC Safety standard(LVD) EN 62368-1:2020+A11:2020 Protection
Over-load
Output current 4CH,5A/CH Certi cation CE,EMC,LVD Short circuit

Output power 4 x (60-120)W Package Environment

Output type Constant voltage Size L120 x W78 x H55mm Operation temperature O O
Ta: -30 C ~ +55 C
O
Gross weight 0.162kg Case temperature (Max.) T c:+75 C

Mechanical Structures and Installations

45mm

GND DMX output +


67mm
DMX input - DMX output -
DMX input + GND
35.5mm

Digital display

M
Setting key

Output LED + Output Red LED -

Output LED + Output Green LED -


Power Input -
Output White LED - 37 mm
48m m
Power Input + Output Blue LED -

Installation rack
DIN Rail Mounting Size:
TS-35/7.5 or TS-35/15

User Manual Ver 2.0.0 1


Wiring Diagram
DMX Master DMX signal

AC100-240V

Note:
1. An DMX signal amplifier is needed if more than
32 decoders are connected, or use overlong signal line,
Constant Voltage

signal amplification should not be more than 5 times


Power Supply

continuously.
12-24VDC

M M M

2. If the recoil effect occurs because of longer signal line or


bad line quality, please try to connect 0.25W 90-120Ω
terminal resistor at the end of each DMX signal line.
3.When display 1OL,2OL,3OL,4OL, correspond to
1,2,3,4 channel overload alarm. When display OHA,
overheat alarm.
W

CW

CW
+ + + + + +

WW

WW
RGBW LED strip

Dual color LED strip

Dual color LED strip


Single color LED strip

Single color LED strip

Single color LED strip

Single color LED strip

If connect with If connect with If connect with


RGBW LED strip Single color LED strip Dual color LED strip
Operation

System parameter setting


● Long press M and ◀ key in the same time for 2s, prepare for setup system parameter: decode mode, grey level, output PWM frequence, output brightness curve,
default output level, automatic blank screen. short press M key to switch six item.
● Decode mode: short press ◀ or ▶ key to switch 1/2/4 channel decode mode("d-1","d-2" or "d-4"). When set as 1 channel decode, the decoder occupy only
1 DMX address, and four channel output the same brightness of this DMX address.
● Grey level: short press ◀ or ▶ key to switch 8bit("b08") or 16 bit("b16"). choose 16 bit if the DMX master support 16 bit.
● Output PWM frequency: short press ◀ or ▶ key to switch 250Hz("F02"), 500Hz("F05"), 1000Hz("F10"), 2000Hz("F20"), 4000Hz("F40"),
8000Hz("F80") or 16000Hz("F16").
Higher PWM frequency, will cause lower output current, higher power noise, but more suitable for camera(No ickers for video).
● Output brightness curve: short press ◀ or ▶ key to switch linear curve("C-L") or logarithmic curve("C-E").
● Default output level: press ◀ or ▶ key to change default 0-100% level ("d00" to "dFF" ) when no DMX input signal.
● Automatic blank screen: short press ◀ or ▶ key to switch enable ("bon") or disable("boF") automatic blank screen.
● Long press M key for 2s or timeout 10s, quit system parameter setting.
DMX mode
DMX mode (001~512)
● Short press M key, when display 001~512, enter DMX mode.
● Press ◀ or ▶ key to change DMX decode start address(001~512), long press for fast adjustment.
DMX Console DMX Decoder Output
● If there is a DMX signal input, will enter DMX mode automatically.
CH1 0-255 CH1 PWM 0-100% (LED R)
● DMX Dimming: Each D4 DMX decoder occupy 4 DMX address when connecting the DMX console.
For example, the defaulted start address is 1, their corresponding relationship in the form: CH2 0-255 CH2 PWM 0-100% (LED G)
CH3 0-255 CH3 PWM 0-100% (LED B)
Stand-alone RGB/RGBW mode CH4 0-255 CH4 PWM 0-100% (LED W)

● Enter stand-alone RGB/RGBW mode only when DMX signal is disconnected or lost.
● Short press M key, when display P01~P30, enter stand-alone RGB/RGBW mode.
● Press ◀ or ▶ key to change dynamic mode number(P01~P30).
● Each mode can adjust speed and brightness.
Long press M key for 2s, prepare for setup mode speed, brightness, W channel brightness. Stand-alone RGB/RGBW mode
Short press M key to switch three item. (P01~P30)
Press ◀ or ▶ key to setup value of each item.
Mode speed: 1-10 level speed(S-1, S-9, S-F).
Mode brightness: 1-10 level brightness(b-1, b-9, b-F).
W channel brightness: 0-255 level brightness(400-4FF). Speed Brightness
(8 level) (10 level,100%)
Long press M key for 2s, or timeout 10s, quit setting.

User Manual Ver 2.0.0 2


Stand-alone dimmer mode
● Enter stand-alone dimmer mode only when DMX signal is disconnected or lost.
● Short press M key, when display L-1~L-8, enter stand-alone dimmer mode.
● Press ◀ or ▶ key to change dimmer mode number(L-1~L-8).
● Each dimmer mode can adjust each channel brightness independently. Stand-alone dimmer mode
Long press M key for 2s, prepare for setup four channel brightness. (L-1~L-8)
Short press M key to switch four channel(100~1FF, 200~2FF, 300~3FF, 400~4FF).
Press ◀ or ▶ key to setup brightness value of each channel.
Long press M key for 2s, or timeout 10s, quit setting.

Restore factory default parameter


● Long press ◀ and ▶ key for 2s, restore factory default parameter, display"RES".
● Factory default parameter: DMX decode mode, DMX decode start address is 1, four channel decode, 8 bit grey level,
2000Hz PWM frequence output, logarithmic brightness curve, output 100% level when no DMX input,
RGB mode number is 1, dimmer mode number is 1, disable automatic blank screen.

RGB change mode list

No. Name No. Name No. Name


P01 Static red P11 Green strobe P21 Red yellow smooth
P02 Static green P12 Blue strobe P22 Green cyan smooth
P03 Static blue P13 White strobe P23 Blue purple smooth
P04 Static yellow P14 RGB strobe P24 Blue white smooth
P05 Static cyan P15 7 color strobe P25 RGB+W smooth
P06 Static purple P16 Red fade in and out P26 RGBW smooth
P07 Static white P17 Green fade in and out P27 RGBY smooth
P08 RGB jump P18 Blue fade in and out P28 Yellow cyan purple smooth
P09 7 color jump P19 White fade in and out P29 RGB smooth
P10 Red strobe P20 RGBW fade in and out P30 6 color smooth

Dimming cur ve setting


Linear dimming cur ve Logarithmic dimming cur ve

100
100 100
Gamma=1.0 Gamma=1.6
90
90 90

80
80 80

70
70 70
PWM duty(%)
duty(%)

PWM duty(%)

60
60 60

50
50 50
PWM

40
40 40

30
30 30

20
20 20

10
10 10

10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100

Brightness(%) Brightness(%)

Malfunctions analysis & troubleshooting

Malfunctions Causes Troubleshooting

1.No power. 1. Check the power.


No light
2. Wrong connection or insecure. 2. Check the connection.
1. Wrong connection of R/G/B/W wires. 1. Reconnect R/G/B/W wires.
Wrong color
2. DMX decode address error. 2. Set corrrect decode address.
1. Output cable is too long. 1. Reduce cable or loop supply.
Uneven intensity
2. Wire diameter is too small. 2. Change wider wire.
between front and
3. Overload beyond power supply capability. 3. Replace higher power supply.
rear,with voltage drop
4. Overload beyond controller capability. 4. Add power repeater.

User Manual Ver 2.0.0 3