100% found this document useful (1 vote)
1K views1 page

Steel Column Schedule

The document provides schedules for steel columns and beams used at different levels of a building. It lists the type and size of steel columns from the ground floor to the second floor and roof. Steel beam sizes are also listed for the second floor and roof levels. Drawings show details of the steel beams and columns, including dimensions and connection details.

Uploaded by

johnkarl.benting
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
1K views1 page

Steel Column Schedule

The document provides schedules for steel columns and beams used at different levels of a building. It lists the type and size of steel columns from the ground floor to the second floor and roof. Steel beam sizes are also listed for the second floor and roof levels. Drawings show details of the steel beams and columns, including dimensions and connection details.

Uploaded by

johnkarl.benting
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

STEEL COLUMN SCHEDULE STEEL BEAM SCHEDULE

GF TO 2F TO ROOF LEVEL SECOND FLOOR BEAMS ROOF BEAMS

C1 W12X53 W10X30 W10X30 W10X33

Weight (kg/m) = 158 Weight (kg/m) = 79 Weight (kg/m) = 45 Weight (kg/m) = 45 Weight (kg/m) = 49

W 12 x 106 W 12 x 53 W 10 x 30 W 10 x 30 W 10 x 33

STEEL BEAM L 3" X 3" X 165 " STEEL BEAM

4-20∅A325
L 3"X3"X165 "
FULL WELD E70XX
TOP VIEW

STEEL
COLUMN WELD E70XX 165 X ANGLE LENGTH
STEEL BEAM 4-20∅A325
4-20∅A325
STEEL COLUMN
TOP VIEW DISCONTINUOUS GIRDER

STEEL BEAM
4-20∅A325

30 mm
L 3"X3"X165 "
L 3" X 3" X 165 " STEEL BEAM
30 mm

A36
A36
L 3X3X5_16
STEEL COLUMN L 3X3X5_16
LATERAL VIEW FRONT VIEW
WELD E70XX 165 X LENGTH
4-20∅A325
30 mm
STEEL COLUMN
FRONT VIEW
LATERAL VIEW 2Bolts:3/4" A325 N CONTINUOUS GIRDER

77.44
3 BEAM TO BEAM CONNECTION DETAILS

40 mm

40mm
S-08 SCALE N.T.S.

117.44mm
75mm
30 mm

155

40 mm
2Bolts:3/4" A325 N

40mm
77.44mm

30 mm 30 mm

75mm
117.44mm
40 mm 75 mm 40 mm

2Bolts:3/4" A325 N
40 mm

A36
155

40

30
75mm

STEEL BEAM

A36
STEEL BEAM

55
75
A36
W 10X30
76.2mmx155mm 76.2mmx115mm
A36

40

30
W 10X30 W 10X30

2 BEAM TO COLUMN FLANGE CONNECTION DETAILS


1 BEAM TO COLUMN WEB CONNECTION DETAILS S-08 SCALE N.T.S.
S-08 SCALE N.T.S.

4 BEAM TO BEAM CONNECTION DETAILS


S-08 SCALE N.T.S.

REPUBLIC ACT 9266


PROJECT TITLE: PROJECT OWNER: PREPARED BY: SHEET CONTENT SHEET NO.
ART IV, SECTION 33

DRAWINGS AND SPECIFICATIONS DULY AS SHOWN


CIVIL ENGINEER SIGNED AND SEALED AS INSTRUMENT DRAWN BY: BENTING, JOHN KARL M.
OF SERVICE ARE INTELLECTUAL
PROPOSED TWO-STOREY BUILDING
S 8.00
PROPERTY.IT SHALL BE UNLAWFUL
FOR ANY PERSON TO DUPLICATE OR MR. HENRY NG LIO
PRC REG. NO: PTR NO: TO MAKE COPIES FOR USED IN APPROVED BY:
REPETITION, WETHER EXECUTED
DATE: ISSUED ON: PARTLY OR WHOLE, WITHOUT THE
WRITTEN CONSENT OF THE AUTHOR LOCATION: NO. 441 LT., ARTIAGA, SAN JUAN CITY
ISSUED AT: DATE: MAY 20 2023

You might also like