Industrial Wiring and Design Project

The document provides instructions for an electrical power and control lab project. Students must draw neat power and control circuits for various systems, including a grinding mechanism, overhead projector, traffic light, star-delta reversible motor, and elevator control. Circuits must include indicating lamps and explanations of how the systems work. Additional requirements include auto-transformer and resistance motor starters, and a three-motor sequential start-stop circuit. The project report must include an introduction, power and control circuits, indicating lamps, simulation, and conclusion, and is due on April 15, 2021.

Uploaded by

Jibril Jundi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
139 views3 pages

Industrial Wiring and Design Project

The document provides instructions for an electrical power and control lab project. Students must draw neat power and control circuits for various systems, including a grinding mechanism, overhead projector, traffic light, star-delta reversible motor, and elevator control. Circuits must include indicating lamps and explanations of how the systems work. Additional requirements include auto-transformer and resistance motor starters, and a three-motor sequential start-stop circuit. The project report must include an introduction, power and control circuits, indicating lamps, simulation, and conclusion, and is due on April 15, 2021.

Uploaded by

Jibril Jundi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

Electrical Power and Control Lab Project

General instruction:

 Your drawings must be neat


 You are expected to draw both power and control circuit
 Group members are not allowed to exceed 4 students
 You are expected to give a brief explanation how your system works.

1. Grinding mechanism
A given grinding mechanism uses two motors. The first motor drives conveyor belt which
move the raw material to grinding hole. Also, this motor will return the grinded material
back by reversing its direction. The second motor drive the grind stone which grind the
raw material. The principle of operation is as follows:
 First raw materials are moved to the grind hole through the conveyor belt for 10sec.
 Then the conveyor belt stops and grinding started and lasts for 20sec.
 Then grinding will stop and the grinded material will return back through the
conveyor belt.

2. Overhead projector
A given overhead projector has a lamp and a fan to cool the system. When the over head
projector is on the lamp will be on. Then after 5sec fan will be on. Then when the off-push
button is pressed to off the projector lamp will be off but the fan will be off after 5sec.

3. Traffic light
A given traffic light control is given in the following procedure.
 First green will be on for 1min.
 Then both green and yellow will be on for 10sec.
 Then Red will be on for 3min
 Finally, red and yellow on for 10sec.
4. Star delta Reversible
You are expected to design both power and control circuit for star delta reversible circuit.
First a motor will start in star connection and will change its connection to delta after
10sec. There will be a reverse pushbutton which reverses the direction of the motor only
if the motor is connected in delta.

5. Elevator control
In elevator control system we have one motor which lefts up in forward direction and
lefts down in reverse direction. You are expected to design control system for ground, 1st
and 2nd floor. In each floor there are three push buttons. In ground we have 3 push
buttons to move 2nd, 1st and to call. In 1st floor we have 3 push buttons to move 2nd,
ground and to call. In 2nd floor we have 3 push buttons to move 1st, ground and to call.
There are switches in every floor to indicate the position of the elevator.

6. Reservoir water pump


There are switches which act as sensors to indicate
 The reservoir is full
 The reservoir is empty
 There is water to be pumped up.

There is a motor which is used as a pump to fill the reservoir. Then conditions to start
motor are if there is no water in the reservoir and if there is water to pump up.

7.Draw the power Circuit, Control circuit and Indicating lamp and explain the working
principle.

a) Auto-Transformer Reduced voltage (Wye) motor starter, (Momentarily on Timer) with


indicating lights

b) Auto-Transformer Reduced voltage (Delta) motor starter, (Momentarily on Timer) with


indicating lights.

c) Primary Resistance close Transition, Reduced voltage motor starter, (Momentarily on


Timer)

d) Secondary Resistance close Transition, Reduced voltage motor starter, (Momentarily on Timer)
8.There are 3 motors(M1,M2,M3) connected in the system, all the motors are OFF initially .When
the start button is press, motor(M1) will start running alone .After 6 seconds motor(M2) will
starts running also together with motor(M1),while motor (M3) is still not running. After 2 seconds
for motor(M1) and motor(M2) running together, motor (M1) will stop running while motor will
continue running alone for 6 seconds, motor(m3) will start also running together with motor (m2)
for 6 seconds. After 2 seconds motor(M2) stop running and motor(M3) continue running alone
for 6 seconds. This procedure will continue subsequently again starting from the first motor to
the third motor.

Report of the project should contain at least the following


1.Introduction
2.power circuit
3.control circuit
4.indicating lamp
5.simulation circuit by (ess or ekts)
6.Conclusion

To be summited at the April ,15,2021


By Ashebir.B