0% found this document useful (0 votes)
32 views8 pages

A.R.K274H Data Sheet

This document provides specifications and details for the A.R.K274H alternator. It includes information on: 1. Electrical and mechanical characteristics such as insulation class, winding configuration, efficiency, and vibration reduction features. 2. Performance standards and certifications it complies with such as IEC60034 and ISO9001. 3. Optional features such as protection levels, excitation systems, and customized configurations. 4. Application areas like prime power, telecom, and standby power. Electrical data is provided including reactance values.

Uploaded by

dmytro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
32 views8 pages

A.R.K274H Data Sheet

This document provides specifications and details for the A.R.K274H alternator. It includes information on: 1. Electrical and mechanical characteristics such as insulation class, winding configuration, efficiency, and vibration reduction features. 2. Performance standards and certifications it complies with such as IEC60034 and ISO9001. 3. Optional features such as protection levels, excitation systems, and customized configurations. 4. Application areas like prime power, telecom, and standby power. Electrical data is provided including reactance values.

Uploaded by

dmytro
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

A.R.

K274H DATA SHEET


SPECIFICATIONS &OPTIONS

Standards
●A.R.K series alternator conforms to the major international standards and specifications, including:
-IEC60034, GB755, BS5000, VDE0530, NEMA, MG1-22, C22.2-100, CSA, AS1359 standard, etc.
●A.R.K series alterantor is certified by ISO9001 quality system.
●A.R.K series alterantor can be used for the generator set of CE mark.
●Other standards and certification can be based on customer requirements.

Electrical characteristics
●Insualtion & Impregnating
Class H insulation.
All wound components are impregnated with meterial and processes designed specially to provide protection against harsh enviroments encountered
in generator application. Resin based meterials are selected and developed to provide the high build required for static windings and the high mechanical
strength required for rotating components.
●3-phase reconnectable with12 ends brought out to the terminals.
●2/3 pitch ,can eliminates triple (3rd, 9th, 15th …) harmonics on the voltage waveform and is found to be the optimumdesign for trouble-free supply
of non-linear loads.
● Telephone interference
THF(as defined by IEC 60034-1) is less than 2%, TIF(as defined by NEMA MG1-32) is less than 50.
● Radio interference
Brushless device and the high quality AVR ensure low levels of interference with radio transmissions.RFI suppression module may be installed if required.
●High efficiency and motor startup capability.

Mechanical properties
●Steel structure.
●Cast aluminum for front and rear cover.
●Rigid assembly, effectively reduces the vibration during running.
●All rotors are dynamically balanced to conform with BS6861.
●Half key dynamic balance is applied in double bearing structure.
●Non-maintenance sealed-for-life ball bearing.
●120% overspeed ability.
Standard
Protection grade
●A.R.K series alternator protection level is IP23.
●Suitable for environment with 95% relative humidity.
●optional
-Inlet and filter, power reduced by 5%.
-Inlet and outlet filter, power reduced by 10% (IP44)
-Anti-condensation heater.
-Stator winding, bearing overheating protection.
-Outlet line design of outlet box.
-Center height can be customized according to requirements.

Excitation and voltage regulation system


MODEL 16 series 18 series 22 series 27 series 4 series 5 series 6 series 7 series
AVR
SX460 Standard Standard Standard Standard
AS440( parallel optional) Optional Optional Optional Optional
SX440( parallel optional) Optional Optional Standard Standard
MX341(with PMG) Optional Optional Optional Optional
MX321(with PMG) Standard Standard

With the self-excited system, the main stator provides power via the automatic voltage regulator(AVR) to the exciter stator. The high efficency AVR ensures the voltage maintaining at the
rated level.
The exciter rotor output is fed to the main rotor through a three phase full wave bridge rectifier. The rectifier is protected by surge suppressor from voltage
spikes of short circuit or phase mismatching.

Application
Prime power, rental, telecom, mobile power station, lighting tower, railway, refrigeration and standby power.

Quality assurance
A.R.K series alterantors are manufactured using production procedures having a quality assurance level to ISO 9001.

Note: Continuous development of our products entitles usto change specification details without notice, thereforethey must not be regarded as binding.
A.R.K274H
Parameters (WINDING 311)

CONTROL SYSTEM SELF EXCITED


A.V.R. OPTIONAL SX440
VOLTAGE REGULATION ± 1.0 %
SUSTAINED SHORT CIRCUIT >300% OF RATED CURRENT

INSULATION SYSTEM H
RATED POWER FACTOR 0.8
PROTECTION IP23
STATOR WINDING DOUBLE LAYER WITH AUXILIARY WINDING
ROTOR WINDING WITH DAMPING CAGE
WINDING LEADS 12
STATOR WDG. RESISTANCE 0.0155 Ohms PER PHASE AT 22°C SERIES STAR CONNECTED
ROTOR WDG. RESISTANCE 1.82 Ohms at 22°C
R.F.I. SUPPRESSION BS EN 61000-6-2 & BS EN 61000-6-4,VDE 0875G, VDE 0875N. refer to factory for others
WAVEFORM DISTORTION NO LOAD < 1.5% NON-DISTORTING BALANCED LINEAR LOAD < 5.0%
MAXIMUM OVERSPEED 2250 Rev/Min
BEARING DRIVE END BALL. 6315 - 2RS. (ISO)
BEARING NON-DRIVE END BALL. 6310 - 2RS. (ISO)
1 BEARING 2 BEARING
WEIGHT COMP. GENERATOR 626 kg 641 kg
WEIGHT WOUND STATOR 253 kg 253 kg
WEIGHT WOUND ROTOR 227.53 kg 216.57 kg
WR² INERTIA 1.9349 kgm2 1.8843 kgm2
SHIPPING WEIGHTS in a crate 659 kg 673 kg
PACKING CRATE SIZE 123 x 67 x 103 (cm) 123 x 67 x 103 (cm)
50HZ 60HZ
TELEPHONE INTERFERENCE THF<2% TIF<50
COOLING AIR 0.514 m³/sec 1090 cfm 0.617 m³/sec 1308 cfm
VOLTAGE SERIES STAR 380/220 400/231 415/240 440/254 416/240 440/254 460/266 480/277
VOLTAGE PARALLEL STAR 190/110 200/115 208/120 220/127 208/120 220/127 230/133 240/138
VOLTAGE SERIES DELTA 220/110 230/115 240/120 254/127 240/120 254/127 266/133 277/138
kVA BASE RATING FOR REACTANCE VALUES 200 200 200 N/A 237.5 245 245 255
Xd DIR. AXIS SYNCHRONOUS 2.11 1.91 1.77 - 2.50 2.31 2.11 2.02
X'd DIR. AXIS TRANSIENT 0.18 0.16 0.15 - 0.21 0.19 0.118 0.17
X'd DIR. AXIS TRANSIENT 0.12 0.11 0.10 - 0.14 0.13 0.12 0.11
Xq QUAD. AXIS REACTANCE 1.28 1.15 1.07 - 1.53 1.41 1.29 1.23
X''q QUAD. AXIS SUBTRANSIENT 0.17 0.15 0.14 - 0.20 0.18 0.17 0.16
X L LEAKAGE REACTANCE 0.08 0.08 0.07 - 0.10 0.09 0.08 0.08
X 2 NEGATIVE SEQUENCE 0.13 0.12 0.11 - 0.16 0.15 0.13 0.13
X 0 ZERO SEQUENCE 0.08 0.07 0.07 - 0.10 0.09 0.08 0.08
REACTANCES ARE SATURATED VALUES ARE PER UNIT AT RATING AND VOLTAGE INDICATED
T'd TRANSIENT TIME CONST. 0.042 s
T''d SUB-TRANSTIME CONST. 0.012 s
T'do O.C. FIELD TIME CONST. 1.1s
Ta ARMATURE TIME CONST. 0.012s
SHORT CIRCUIT RATIO 1/Xd
A.R.K274H
Three Phase Efficiency Curves (WINDING 311) 50HZ

A.R.K184ES
A.R.K274H
Three Phase Efficiency Curves (WINDING 311) 60HZ
A.R.K274H
Locked Rotor Motor Starting Curve (Winding 311)
A.R.K274H
Three-phase Short Circuit Decrement Curve.No-load Excitation at Rated Speed
Based on srar(wye) connection.

1.The following multiplication factors should be used to adjust the values from curve between time 0.001 seconds and the minimum current
point in respect of nominal operating voltage

50HZ 60HZ
Voltage Factor Voltage Factor
380V X 1.00 416V X 1.00
400V X 1.07 440V X 1.06
415V X 1.12 460V X 1.12
440V X 1.18 480V X 1.17
The sustained current value is constant irrespective of voltage level

2.The following multiplication factor should be used to convert the values calculated in accordance with NOTE 1 to those applicable to the various types
of short circuit :

3-phase 2-phase L-L 1-phase L-N


Instantaneous x 1.00 x 0.87 x 1.30
Minimum x 1.00 x 1.80 x 3.20
Sustained x 1.00 x 1.50 x 2.50
Max. sustained duration 10 sec. 5 sec. 2 sec.
All other times are unchanged
3.Curves are drawn for Star (Wye) connected machines.
For other connection the following multipliers should be applied to current values as shown :
Parallel Star = Curve current value X 2
Series Delta = Curve current value X 1.732
A.R.K274H
Winding 311 / 0.8 Power Factor
RATINGS
Class - Temp Rise Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C
Series Star (V) 380 400 415 440 380 400 415 440 380 400 415 440 380 400 415 440
Parallel S tar (V) 190 200 208 220 190 200 208 220 190 200 208 220 190 200 208 220
Series Delta (V) 220 230 240 254 S 230 240 254 220 230 240 254 220 230 240 254
50HZ
kVA 182.0 182.0 182.0 N/A 200.0 200.0 200.0 N/A 212.0 212.0 212.0 N/A 220.0 220.0 220.0 N/A
kW 145.6 145.6 145.6 N/A 160.0 160.0 160.0 N/A 169.6 169.6 169.6 N/A 176.0 176.0 176.0 N/A
Efficiency (%) 93.3 93.5 93.6 N/A 93.0 93.3 93.4 N/A 92.8 93.1 93.3 N/A 92.7 93.0 93.2 N/A

Class - Temp Rise Cont. F - 105/40°C Cont. H - 125/40°C Standby - 150/40°C Standby - 163/27°C
Series Star (V) 416 440 460 480 416 440 460 480 416 440 460 480 416 440 460 480
Parallel S tar (V) 208 220 230 240 208 220 230 240 208 220 230 240 208 220 230 240
Series Delta (V) 240 254 266 277 240 254 266 277 240 254 266 277 240 254 266 277
60HZ
kVA 218.8 225.0 225.0 235.0 237.5 245.0 245.0 255.0 250.0 258.8 258.8 275.0 256.3 265.0 265.0 280.0
kW 175.0 180.0 180.0 188.0 190.0 196.0 196.0 204.0 200.0 207.0 207.0 220.0 205.0 212.0 212.0 224.0
Efficiency (%) 93.2 93.4 93.6 93.7 93.0 93.2 93.5 93.6 92.8 93.1 93.3 93.4 92.7 93.0 93.3 93.3