0% found this document useful (0 votes)
37 views14 pages

Type A Vessel - Pre-Q Clarification Checklist (Rev.02 - 2022) - 18.02.2023

This document is a pre-qualification checklist for a type A drilling vessel named GEO MARITIMER. It lists 30 items related to the vessel's equipment and facilities and notes the owner's comments and QG Marine's comments on each item. Key points covered include the main deck layout and markings, accommodation spaces, fuel and water capacities and management systems, dry bulk and liquid mud tanks, safety equipment, and more. The owner's responses indicate the vessel meets most requirements with some minor works still pending.

Uploaded by

mohamed hathil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views14 pages

Type A Vessel - Pre-Q Clarification Checklist (Rev.02 - 2022) - 18.02.2023

This document is a pre-qualification checklist for a type A drilling vessel named GEO MARITIMER. It lists 30 items related to the vessel's equipment and facilities and notes the owner's comments and QG Marine's comments on each item. Key points covered include the main deck layout and markings, accommodation spaces, fuel and water capacities and management systems, dry bulk and liquid mud tanks, safety equipment, and more. The owner's responses indicate the vessel meets most requirements with some minor works still pending.

Uploaded by

mohamed hathil
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 14

Classification: Internal

PRE-Q CLARIFICATION CHECKLIST


(TYPE A - DP2 DRILLING VESSEL)

VESSEL NAME : GEO MARITIMER OWNER/OPERATOR : GENESIS MARINE DATE : 18-02-2023

ITEM DESCRIPTION OWNER COMMENTS QG MARINE COMMENTS


1 Main Deck *
1- Effective main deck area full clear from obstruction

2.- Deck stanchion (3 section)

Page 1 of 14Rev.02/2022
Classification: Internal

3.- Deck marking - section Port and Starboard

Tentatively on 21 Feb 23
crew will painted on crash rail .

4- IMDG marking at the stern

5- Deck sheathing condition

Page 2 of 14Rev.02/2022
Classification: Internal

- Clear access for safe heaven at P/S crash rail

6- Pad-eye and lashing for sea fastening of cargoes

7- Manhole sampling point (2” dia) for quick sampling for


Liquid Mud/Brine/Water

Ship Condition Survey Photos *

Page 3 of 14Rev.02/2022
Classification: Internal

8- Wheelhouse

9- Monkey island / funnel

10- Crew cabins and toilets

11- Galley

Page 4 of 14Rev.02/2022
Classification: Internal

12- Mess room

13- Chiller and freezer

Chiller freezer

14- Dry stores

Page 5 of 14Rev.02/2022
Classification: Internal

15- Bow thruster room

16- Engine control room (ECR)

17- Engine room

Page 6 of 14Rev.02/2022
Classification: Internal

18- Steering room/compartment

19- Superstructure / outside accommodation

20- Forward / aft station

Page 7 of 14Rev.02/2022
Classification: Internal

21- Windlass and winches

22- Life raft

23- Rescue boat

Page 8 of 14Rev.02/2022
Classification: Internal

24- Sick bay / hospital

25- Laundry room / dryer room

26- Recreation / gym room

Page 9 of 14Rev.02/2022
Classification: Internal

27- Fuel connections and manifolds

28- Fresh water connections and manifolds

29- Dry bulk tanks

Page 10 of 14Rev.02/2022
Classification: Internal

30- Brine tanks

Fuel Consumption
- All main engines’ total daily fuel consumption can be
Yes, 2 main engines
recorded and taken from Engine Control Room
- All generators’ total daily fuel consumption can be
3 Yes, 2 AE
recorded and taken from Engine Control Room
- All main engines fuel flow meter available with latest
yes
calibration certificate (not more than 1 year)
- All generators fuel flow meter available with latest
yes
calibration certificate (not more than 1 year)
Fresh Water
- Capacity – Minimum 400 m3 918m3
- Tank cleaning certificate Completed Awaiting Cert.
- Fresh water flow meter with printed ticket and latest
yes
calibration certificate (not more than 1 year)
- Manifold connection 3" dia male camlock coupling Yes
4 - 2 x water flat cargo transfer hose with 3” dia x 40
meters assembly with male and female camlock On board has one unit
connection
- Jacket type hose floater provided for the transfer hose Yes
- Assorted cross-over connection for fresh water Yes
- Piping, connection, and manifold – blue colour coded
Yes
and marked
5 Fuel Oil
- Capacity – Minimum 400 m3 946 m3
- Fuel oil flow meter with printed ticket and latest
Yes
calibration certificate (not more than 1 year)
- Manifold connection 3” dia male camlock connection Midship is Camlock 3”, and stern for loading and discharging is
located at mid-ship and stern for loading/discharging TODO 3” and TODO 4”
- 2 x fuel flat cargo hose with 3” dia x 40 meters
assembly with TODO breakaway coupling with male Onboard has one set
and female camlock connection
- Jacket type hose floater provided for the transfer hose Yes

Page 11 of 14Rev.02/2022
Classification: Internal

- Assorted cross over connection for fuel oil Yes


- Piping, connection, and manifold – brown colour coded
Yes
and marked
Dry Bulk / Manifold
- Capacity – Minimum 150 m3 320 m3
- Number of segregated dry bulk tank – Minimum 4
5 tank Capacity @ 64 m3 each
tanks
6 - Dry bulk manifold 4” dia male camlock for both P/S
Yes
mid and stern location
- Intake/discharge line for dry bulk – Minimum 2
Yes
independent system
- Piping, connection and manifold colour coded for each
Yes
product cement, barite, bentonite, etc.
Liquid Mud / Brine Tank
- Liquid mud capacity – Minimum 400 m3 Capacity 598.8m3 ( 6 Tanks )
- Brine capacity – Minimum 200 m3 Capacity 398.6m3 ( 4 Tanks )
- Tank cleaning certificate
- Two (2) separated system including loading/discharge
Yes
line where two product can be stored separately
- Brine/liquid mud manifold 4” dia male camlock for both
7 Yes
P/S mid and stern location
- Brine flow meter with printed ticket and latest
Yes (No printing)
calibration certificate (not more than 1 year)
- Drain plug to drain out used product/residues for
N/A
thorough cleaning at lowest point of the tank
- Heavy duty agitator for all liquid mud tanks Yes
- Piping, connection and manifold colour coded for liquid
Yes
mud / brine tank
Accommodation / Facilities
- Number of cabins 14
- Laundry machine(washer/dryer) sufficient for POB yes
- Food provision for ship crew and passengers in 30 For frozen one month and
8 Please confirm adequate storage space available
days chiller less one week.
- Plastic bags/containers for preservation of daily food
Available
sample for 3 days
- Cabin for company man / client with attached toilet and
Cabin for company man one bunk but satellite TV in progress
satellite TV – Minimum 1
9 Safety and Industrial Hygiene
- Location of cascade system and manifold Bridge deck port and stbd
- Cascade system latest servicing certificate (not more
Yes
than 6 months)
- Fixed H2S / LEL gas detection system – Minimum 4 Yes
locations
Page 12 of 14Rev.02/2022
Classification: Internal

- Fixed H2S / LEL gas detection system calibration


Yes
certificate (not more than 3 months)
- Fixed H2S / LEL gas detection system alarm set as
Yes
per QG MOM requirements
- Total SCBA sets onboard meets 125% of POB Yes
- Portable detector (Toxy Clip) for all crew working on
Yes
deck at a time – Minimum 3 sets
- Fast rescue craft – Minimum 6 persons capacity and
Yes
diesel operated
- Heat index monitoring device – Minimum 2 sets for
deck and engine room (applicable during summer yes
time)
- Cooling vest – Minimum 3 sets (applicable during
Yes
summertime)
- Heat index flag and display board – Minimum 2
(applicable during summer time)
Crew Evaluation
- All crew SOEF/SREF and CV submitted to Qatargas
Marine for approval
10 - Master and Chief Officer possess Safety Officer
Yes
Certificate
- Senior deck and engine officers including Bosun
Yes
possess FRC certificate
Medical Stock
11 - Qatargas medical stock list complete Yes
- Industrial first aid kit complete yes
Communication and Navigation
- VHF channel program to RGA P1 (159.00 Mhz) Yes
- VHF channel program to RGA P2 (160.050 Mhz) Yes
- VHF channel program to NFB P1 (157.450 Mhz) NOT APLICABLE
- Multi band air to ground radio program at 122.42 Mhz Yes
12 - DP operation manual approved by classification Please confirm Yes or No If no target date After FMEA test
society Tentatively on 21Feb 23
- Last FMEA date (not more than 5 years) Please confirm Yes or No If no target date Tentatively on 21Feb 23
- Last annual DP trial date (not more than 1 year)
- DP printer able to print screen shots Yes, can take screenshot on USB and print.
- DP reflectors or transponders – Minimum 4 yes
- Confirm power redundancy in percentage (%) We don’t have ASOG & CAMO onboard
13 FiFi System
- Last test conducted date 16-Jan-2023
- Number of monitors 2

Page 13 of 14Rev.02/2022
Classification: Internal

- Provide photo of P/S monitor test

Reefer Socket
14 - Power connections and leads for freezer containers to yes
any point on deck @100 Amp x 415-450V x 50 cycles
– Minimum 6 sets
Fender and Gangway
- Appropriate fenders fitted for STS / port operations yes
15 - Gangway clear from loading manifold and hoses Yes
- Condition of gangway for access in port (specify
4mtrs / 8mtrs & 6 Mtrs Gangway
length of gangway)
Outside Accommodation N
16 - All stairways have anti-slip surface / pad for slip and
yes
fall prevention
- All fire dampers / flaps are easily operable and marked yes
Emergency Escape Hatch / Door
- Each hatch / door is clearly accessible and easily
yes
operatable by single person
17 - Routine maintenance in place and included in the
yes
vessel’s PMS
- Condition of each emergency escape hatch / door on
yes
main deck (provide inside and outside photo)

Note : (*) – to provide photo for each item in the list

Page 14 of 14Rev.02/2022