0% found this document useful (0 votes)
83 views

MSDS PETROFLAG TEST Kit

This document summarizes the components and safety information for a PetroFLAG test kit. The kit contains two snap ampules of methanol solution and a screw top vial of non-hazardous contents. It also describes a high range reagent consisting of a single snap ampule of diglyme. Contact with any of the reagents can cause eye, skin or respiratory irritation. Proper protective equipment should be worn and the materials stored properly. Spills should be cleaned up following the procedures outlined in the document.

Uploaded by

rogelgerardo643
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views

MSDS PETROFLAG TEST Kit

This document summarizes the components and safety information for a PetroFLAG test kit. The kit contains two snap ampules of methanol solution and a screw top vial of non-hazardous contents. It also describes a high range reagent consisting of a single snap ampule of diglyme. Contact with any of the reagents can cause eye, skin or respiratory irritation. Proper protective equipment should be worn and the materials stored properly. Spills should be cleaned up following the procedures outlined in the document.

Uploaded by

rogelgerardo643
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Material Safety Data Sheet

To comply with OSHA's Hazard Communication Standard, 29 CFR 1910.1200.

PETROFLAG TEST KIT

Section I --- Manufacturer

Manufacturer's Name: Emergency Telephone Number:


Dexsil Corporation USA (800) 424-9300 (CHEMTREC)
INT'L (202) 483-7616

Address: Telephone Number:


One Hamden Park Drive (203) 288-3509
Hamden, CT 06517

Date Prepared: 06-20-01


Date Reviewed: 06-20-01

Section II --- Identification of Hazardous Ingredient


The PetroFLAG Test Reagent Kit consists of two snap ampules (extraction solvent and
calibration solvent) and a screw top vial. Screw top vial contents are non-hazardous. The
PetroFLAG High Range Reagents consist of one snap ampule.

Component Ingredients TLV/(PEL) CAS # Concentration


Ampule 1 Methanol Sol’n 200 ppm/(200 ppm) 67-56-1 50%
“Extraction
Solvent”

Ampule 2 Methanol Sol’n 200 ppm/(200 ppm) 67-56-1 50%


“Calibration
Standard”

“High Range” Diglyme 5 ppm 111-96-6 100%


Section III --- Physical Characteristics
Property Ampule 1 Ampule 2 High Range Ampule

Boiling Pt oC 64.5 64.5 162

Vapor Pressure
mm Hg @ 21oC 97 97 1.7

Solubility in Water miscible miscible 100%

Specific Gravity 0.79 0.79 0.95

Percent Volatile 99.9 99.9 100

Evaporation Rate
Butyl Acetate =1 5.9 5.9 0.36

Appearance clear, colorless clear, colorless colorless

Odor pleasant pleasant ether-like

Section IV --- Fire and Explosion Hazard


Flash Point Ampule 1 50oF
Ampule 2 50oF
High Range Ampule 135oF

Flammable Limit Ampule 1 Unknown


Ampule 2 Unknown
High Range Ampule Upper: 17.4 Lower: 1.5

Extinguishing Media Ampule 1 and 2: Dry chemical, foam, CO2.


High Range Ampule: Dry powder, water fog, CO2.

Special Fire Fighting Procedures Ampule 1 and 2: None,


High Range Ampule: Wear SCBA and protective clothing.

Section V --- Reactivity Data


Stability
All components are stable.
Incompatible With
Ampule 1 and 2: None. High Range Ampule: Avoid strong oxidizers.
Hazardous Decomposition Productions
Ampule 1 and 2: Solutions are stable. High Range Ampule: None expected.
Hazardous Polymerization
Will not occur.
Conditions to Avoid
Ampule 1 and 2: Excessive heat. High Range Ampule : May form peroxides on exposure to air.
Section VI --- Health Hazard Information
First Aid
In case of contact with reagents, rinse well with water. If swallowed, induce vomiting
immediately by giving two glasses of water and sticking finger down throat.

Eye Contact
For all kit components, flush eyes with large amounts of water for 15 minutes. Seek medical
attention.

Skin contact
Flush with large amounts of water. Use soap and water to wash away organic components.
Remove contaminated clothing and wash before reuse.

Inhalation
In case of inhalation, remove to fresh air. Seek medical attention.

Toxicological Information
Harmful if inhaled or swallowed. Diglyme may cause drowsiness, headache, cyanosis, central nervous
system depression, nausea and vomiting if inhaled or swallowed. Exposure may cause skin irritation
and may be harmful if absorbed through the skin. Ingestion will cause gastrointestinal disturbances.
Diglyme is a member of the group of compounds known as “glycol diethers” which, in studies on
laboratory animals have been shown to cause reversible testicular and sperm damage. May be a rick
for women of child bearing potential. Methanol and diglyme components are identified on lists in
CERCLA, SARA Sec. 313 and TSCA.

Section VII --- Spill, Leak and Disposal Procedures


Spills and Leaks Ampule 1 - Methanol solution
Solvent absorbent recommended for spills. Flush area with water.

Ampule 2 - Methanol solution


Solvent absorbent recommended for spills. Flush area with water.

High Range Ampule - Diglyme


Solvent absorbent recommended for spills. Place material into a container for
disposal later.

Disposal Used reagents contain oil and solvent. Dispose of as an organic waste in
accordance with all applicable federal, state and local environmental regulations.
Section VIII --- Special Protection Information
Respiratory protection None required where adequate ventilation conditions exists. If
airborne concentration is high, use a chemical cartridge respirator.

Ventilation Perform test only in a well ventilated area.

Protective gloves Always wear rubber gloves when performing the PetroFLAG test.

Eye protection Wear safety glasses.

Other protective equipment Wear appropriate safety equipment when performing test on site.

Section IX --- Special Precautions and Comments


Storage and Handling Information
Store test kits in a cool, dry place out of contact with air. Check expiration date prior to performing
test.

DOT Class (As originally packaged by Dexsil Corporation)


Approval CA-9610010, Packaging conforms to conditions and limitations specified in 49 CFR 173.4.

NA=Not available or not applicable


NF=Not found
NE=Not established

The information in this Material Safety Data Sheet meets the requirements of the United States
OCCUPATIONAL SAFETY AND HEALTH ACT and regulations promulgated thereunder (29 CFR
1910.1200 et. seq.) and the Canadian WORKPLACE HAZARDOUS MATERIALS INFORMATION
SYSTEM. This document is intended only as a guide to the appropriate precautionary handling of
the material by a person trained in, or supervised by a person trained in, chemical handling. The user
is responsible for determining the precautions and danger of these chemicals for his or her particular
application. Depending on usage, protective clothing including eye and face guards and respirators
must be used to avoid contact with material or breathing chemical vapors/fumes.
Exposure to this product may have serious adverse health effects. These chemicals may interact with
other substances. Since the potential uses are so varied, Dexsil cannot warn of all of the potential
dangers of use or interaction with other chemicals or materials. Dexsil warrants that the chemicals
meet the specifications set forth on the label.
DEXSIL DISCLAIMS ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED WITH REGARD TO THE
PRODUCT SUPPLIED HEREUNDER, ITS MERCHANTABILITY OR ITS FITNESS FOR A PARTICULAR
PURPOSE.
The user should recognize that this product can cause severe injury and even death, especially if
improperly handled or the known dangers of use are not heeded. READ ALL PRECAUTIONARY
INFORMATION. As new documented general safety information becomes available, Dexsil will
periodically revise this Material Safety Data Sheet.
CHEMTREC emergency telephone number is to be used ONLY in the event of CHEMICAL
EMERGENCIES involving a spill, leak, fire, exposure, or accident involving chemicals. All non-
emergency questions should be directed to the Customer Service Dept. at 1-203-288-3509.

For additional information, contact Dexsil. Rev. 2,version2