0% found this document useful (0 votes)
83 views7 pages

Sup 602s Signal Isolator Datasheet

The document provides information about a signal isolator product, including its applications, features, parameters, wiring diagram, dimension, and ordering code. It contains detailed technical specifications and descriptions of the isolator.

Uploaded by

Md. Mamon Rana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
83 views7 pages

Sup 602s Signal Isolator Datasheet

The document provides information about a signal isolator product, including its applications, features, parameters, wiring diagram, dimension, and ordering code. It contains detailed technical specifications and descriptions of the isolator.

Uploaded by

Md. Mamon Rana
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Datasheet

Signal isolator
SUP-602S

Committed to process automation solutions


Tel: 86-15158063876
E-mail: [email protected]
www.supmea.com
F-
Datasheet

Signal isolator
SUP-602S
SUP-602S provides an isolated working power supply to the transmitter, and detect the current in the circuit
and output current or voltage signal via isolation and transmission at the same time. The input, output and
power supply terminals are isolated from each other, characterized by the advantages such as fast
response, low power consumption and good temperature characteristics.
This product adopts smart design, provided with many advanced technologies such as internal digital
adjustment, no potentiometer and zero-point auto-calibration. Through matching with various types of
instruments and DCS, PLC and other devices, the product has been widely used in major projects in
petroleum, petrochemical, manufacturing, power, metallurgy and other industries.

Applications

 Petroleum
 Petrochemical
 Manufacturing
 Power
 Metallurgy

Features

 The input, output and power supply terminals are


isolated from each other.
 Fast response, low power consumption and good
temperature characteristics. Signal isolator
 This product adopts smart design, provided with many
advanced technologies such as internal digital
adjustment, no potentiometer and zero-point
auto-calibration.
Parameters
Product Signal isolator
Model SUP-602S
DC: 0(4)mA~20mA; 0mA~10mA
Allowed input signal Other signal types may be customized as required, see the
product label for details
Input impedance about 100Ω
Current: 0(4)mA~20mA; 0mA~10mA
Voltage: 0(1) V~5V; 0V~10V
Allowed output signal
Other signal types may be customized as required, see the
product label for the specific signal types
Active: 0(4)mA~20mA:≤500Ω;0mA~10mA: ≤1kΩ
Passive: RL≤【(U-3)/0.02】Ω
U refers to the circuit service voltage
Output load capacity
Voltage: 0(1)V~5V:≥1MΩ; 0V~10V:≥2MΩ
Other load demands may be customized as required, see the
product label for details.
Output ripple ≤5mVrms(load 250Ω)
Open circuit voltage≤26V
Distribution output voltage Full-load voltage≥23V
In case of full-load 20mA output, voltage≥17.5V
Accuracy of isolated transmission ±0.1%F∙S(25℃±2℃)
Temperature drift 40ppm/℃
≤0.5s
Response time Dielectric strength (leakage current 1mA, with test time of 1
minute):≥1500VAC (among input/output/power supply)
Insulation resistance ≥100MΩ (among input/output/power supply)
EMC EMC conforms to IEC61326-3
Power supply DC 18~32V (typical value 24V DC)
Single-channel output : 0.6W
Full-load power(In case of 24V DC)
Double-channel full-load output : 1.5W

Panel indicator
Power indicator (green). When the instrument is powered, it lights
PWR
up all the time.
Input signal status indicator, red.
The indicator does not light up during normal operation;
ALM The indicator flashes in case of input signal failures;
The indicator lights up all the time when the input signal is out of
range.
Operational Environment
Ambient temperature during operation −20℃~+60℃
Allowed relative humidity during operation 10%RH~90%RH(40℃)
Allowed atmospheric pressure during operation 80kPa~106kPa
Allowed ambient temperature during storage and transportation −40℃~+80℃
Wiring

Dimension

Unit:mm

9 10 9 10 9 10 9 10 9 10
7 8 7 8 7 8 7 8 7 8
5 6 5 6 5 6 5 6 5 6

PWR PWR PWR PWR PWR

ALM ALM ALM ALM ALM

PRO PRO PRO PRO PRO

1 2 1 2 1 2 1 2 1 2
3 4 3 4 3 4 3 4 3 4

Width×Height×Depth(12.7mm×110mm×118.9mm) 35mm guide-rail type installation


Please position stably and firmly
Ordering code

SUP-602S-I1T1-I2T0-O1T1-O2T0-O3T0-O4T0-DO0-V1 Description
SUP-
- - - - - - - - Current/Voltage Isolator
602S
I1T1 (4~20) mA
Input I1T2 (0~20) mA
signal I1T3 (0~5) V
1 I1T4 (1~5) V
I1T5 (0~10) V
Non input signal 2
I2T0 (Input signal 2 keeps consistent
with input signal 1)
I2T1 (4~20) mA
Input signal 2 I2T2 (0~20) mA
I2T3 (0~5) V
I2T4 (1~5) V
I2T5 (0~10) V
I2TZ Other signal 2
O1T1 (4~20) mA
O1T2 (0~20) mA
Output signal 1 O1T3 (0~5) V
O1T4 (1~5) V
O1T5 (0~10) V
Non Output signal 2
O2T0
(Input 2 only support Output 2)
O2T1 (4~20) mA
Output signal 2 O2T2 (0~20) mA
O2T3 (0~5) V
O2T4 (1~5) V
O2T5 (0~10) V
Non Output signal 3
O3T0
(Input 2 only support Output 2)
O3T1 (4~20) mA
Output signal 3 O3T2 (0~20) mA
O3T3 (0~5) V
O3T4 (1~5) V
O3T5 (0~10) V
Non Output signal 4
O4T0
(Input 2 only support Output 2)
O4T1 (4~20) mA
Output signal 4 O4T2 (0~20) mA
O4T3 (0~5) V
O4T4 (1~5) V
O4T5 (0~10) V
DO0 Non distribution output
24VDC
Distribution Output (No-load voltage ≤ 26V, full-load
D01
voltage ≥ 23V, only current input
can be selected)
V1 24VDC (18~32)
Power supply
V2 220VDC (85~265)
Note: Dual-channel and one-in three-out, one-in and four-out can only do 24V, do not support other