0% found this document useful (0 votes)
58 views5 pages

W TNT

Wavecom Instruments manufactures the TnT Series appliance testers. The Gen 4 models have enhanced features like a meter mode for instant power measurements and increased memory storage. Key features include class I and II appliance testing, RCD testing, insulation testing up to 500V, and a rechargeable power bank that allows 3000 sets of tests on a single charge. The TnT Series provides reliable and comprehensive appliance safety testing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
58 views5 pages

W TNT

Wavecom Instruments manufactures the TnT Series appliance testers. The Gen 4 models have enhanced features like a meter mode for instant power measurements and increased memory storage. Key features include class I and II appliance testing, RCD testing, insulation testing up to 500V, and a rechargeable power bank that allows 3000 sets of tests on a single charge. The TnT Series provides reliable and comprehensive appliance safety testing.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 5

Wavecom Instruments

TnT Series
Appliance Testers

Contact us Distributed By
South Australia Victoria Western Australia
257 Grange Road Suite 8, 79-83 High Street, Unit 2/17 Casino Street,
Findon, SA 5023 Kew, VIC 3101 Welshpool, WA 6016
P: +61 08 8243 3500 P: +61 03 9897 4711 P: +61 08 9353 1943
F: +61 08 8243 3501 F: +61 08 8243 3501 F: +61 08 9353 4319
E: [email protected] E: [email protected] E: [email protected]
TnT Series

Overview
With four generations of Industry respected models and a proven pedigree you can rely on,
Wavecom’s TnT Range is the industry benchmark in Test and Tag units. The Gen 4 TnT series
provides a host of features and functions never before seen on any appliance tester.

With solid 10 Amp and 20 Amp (TnT ELX, +XM and RCDX Models) capabilities and a totally new
Meter Mode function (providing instant power, voltage and current measurements) the Gen 4 TnT
Series boasts a comprehensive list of tests and analysis as required under our AS/NZS 3760:2010
standards.

Designed and manufacturered in Australia to meet stringent testing requirements - some of the
tighest in the world - the TnT Gen 4 series now sets its own new standard of reliability and ruggedness,
which also comes with a 24 month conditional warranty.

The ELB and RCD now feature power bank technology. This gives you greater versatility in
how you use your battery power compared to the limited capabilities of the AA, AAA alkaline
& rechargable batteries that are available in other brands of testers. Not only can you charge
up your tester, you also have available to you back up power for your mobile phone, GPS,
camera and numerous mobile devices.

The Power Bank Charger will allow you to conduct 3000 sets of tests before you need to
recharge the power pack. The power bank can be recharged from your cigarette lighter or
phone charger in your car. This new ELB and RCD models comes with AC/DC power options
and incorporates many of the same advanced features found in the range of TnT and TnP
testers manufacturered by Wavecom right here in Australia.

Features
◊ Meter Mode function ◊ Large fonts during tests showing results and
◊ Simple One Button Testing progress
◊ 5000 items storage or optional 20,000 item ◊ Flashing LED Fail Indicator
memory (+M, +XM models only) ◊ Specially formulated high impact resistant,
◊ Mains/Input Polarity Test on Startup flame retardant housing
◊ True RCD Ramp up Test (RCD, RCDX +, +M, +XM ◊ Over 3000 sets of tests can be completed on
models only) a single charge (ELB and RCD models only)
◊ 10 amp operation (20 Amp available in ELX, ◊ Conditional 24 month warranty
+XM and RCDX models) ◊ Fully Australian designed & manufactured
◊ Test icons and symbols on Large LCD

Contact us Distributed By
South Australia Victoria Western Australia
257 Grange Road Suite 8, 79-83 High Street, Unit 2/17 Casino Street,
Findon, SA 5023 Kew, VIC 3101 Welshpool, WA 6016
P: +61 08 8243 3500 P: +61 03 9897 4711 P: +61 08 9353 1943
F: +61 08 8243 3501 F: +61 08 8243 3501 F: +61 08 9353 4319
E: [email protected] E: [email protected] E: [email protected]
TnT Series

Specifications
Checks Polarity and continuity of mains supply by LED indicators
Mains Supply Tests
(A-N, A-E, and N-E). (Flashing red LED indicates test fail)

Appliance Check: Ensures appliance is plugged in and turned on.

Class I Tests- Earth Bond Test: 200mA test current. Pass level Less than 1.0 Ω. Measurement: 0.01Ω to 10 Ω.
Earthed Appliance Insulation Test: 500VDC / 250VDC. Pass level Greater than 1M Ω. Measurement: 0.1Ω to 10MΩ.
*See also LeakageTest

Appliance Check: Ensures appliance is plugged in and turned on.


Class II Tests - Earth Bond Test: 200mA test current. Pass level Less than 1.0Ω. Measurement: 0.1Ω to 10Ω.
Double Insulated
Insulation Test: 500VDC / 250VDC. Pass level greater than 1MΩ. Measurement: 0.1Ω to 10MΩ.
Appliance
*See also Leakage Test

Earth Bond Test: 200mA test current. Pass level Less than 1Ω. Measurement: 0.01Ω to 10.0Ωs
Extension Lead Tests Insulation Test: 500VDC / 250VDC. Pass level Greater than 1MΩ. Measurement: 0.1Ω to 10.0MΩ.
Continuity/Polarity Test: 250VAC. Check continuity and polarity of leads. Displays Pass/Fail

Leakage Current: 0 to 30.0mA at 200 to 265V


Power Measurement Voltage: 200 to 265VAC - Power Factor: 0.00 to 1.00
Apparent Power: 0 to 2400VA -Power 0 to 2400W

Green flashing LED denotes Meter Mode is engaged


Load Current: 0.0 to 10Amp
Meter Mode® Voltage: 200 to 265VAC
Apparent Power: 0 to 2400VA
Power: 0 to 2400W

Trip Current: 2 to 500mA in 1mA steps - User selectable.


RCD Tests Trip Time: 0 to 3,000ms at .001sec resolution.
Current Ramp Trip Test: 0 to 500mA in 1mA increments.

Leakage Current: 0 to 30.0mA at 200 to 265V


Earth Leakage Test: 240VAC Mains. Pass level 1, 2.5, 5.0 mA leakage test levels
Leakage Tests
Note 1: Pass level for CLASS 1 is 5 mA; pass level for CLASS 2 is 1 mA
Note 2: Leakage test may be performed if a standard CLASS 1 or CLASS 2 is not possible

Memory 5000 Items - 20,000 item upgrade optional

Battery 4400 mAH, 22WH, Charge Time 1-2 Hours

Contact us Distributed By
South Australia Victoria Western Australia
257 Grange Road Suite 8, 79-83 High Street, Unit 2/17 Casino Street,
Findon, SA 5023 Kew, VIC 3101 Welshpool, WA 6016
P: +61 08 8243 3500 P: +61 03 9897 4711 P: +61 08 9353 1943
F: +61 08 8243 3501 F: +61 08 8243 3501 F: +61 08 9353 4319
E: [email protected] E: [email protected] E: [email protected]
TnT Series

Comparison

Model EL ELB RCD RCDX ELX + +M +XM

Meter Mode ü ü ü ü ü ü ü ü

Class I/Class II Tests ü ü ü ü ü ü ü ü


Extension Lead Test /
ü ü ü ü ü ü ü ü
Socket Polarity

Leakage Current ü ü ü ü ü ü ü ü

500V/250V Insulation ü ü ü ü ü ü ü ü

Main Supply Test ü ü ü ü ü ü ü ü

RCD Testing ü ü ü ü ü

Power Measurement ü ü ü

Data Connectivity ü ü ü
via USB Port

Printer Connectivity ü ü ü
via PC

Direct Printer Connectivity ü ü


via Serial Port

Direct Keyboard
ü ü
Connectivity
Test Load - up to 20A ü ü ü
(10 Amps Standard)

Memory - 5,000 items ü ü

Memory - 20,000 items ü ü


(Optional)

WinPATS Premium Software ü ü ü

Lithium Ion Battery Pack ü ü ü

Contact us Distributed By
South Australia Victoria Western Australia
257 Grange Road Suite 8, 79-83 High Street, Unit 2/17 Casino Street,
Findon, SA 5023 Kew, VIC 3101 Welshpool, WA 6016
P: +61 08 8243 3500 P: +61 03 9897 4711 P: +61 08 9353 1943
F: +61 08 8243 3501 F: +61 08 8243 3501 F: +61 08 9353 4319
E: [email protected] E: [email protected] E: [email protected]
TnT Series

Contents
◊ TnT Appliance Tester ◊ Locking IEC Power Cable (1800mm Blue)
◊ 12 Month Calibration Certificate ◊ User Manual & Quckstart Guide
◊ IEC Test Lead (500mm Orange) ◊ Wavecom Keyboard (TnT +M, +XM models
◊ Earth Lead with Alligator Clips only)
(1800mm Black) ◊ Operators Manual

Optional Accessories
◊ 500mm Earth Strap (TnT-ES-500)
◊ 3 Phase Adaptor to 32A - 4 or 5 Pin (WCM-3Phase)
◊ 3 Phase Multi-Adaptor to 32 A (WCM-3PH-MADP)
◊ 3 Phase Multi-Adaptor Switch Selectable to 40 A (WCM-3PH-MADP-SW)
◊ Adaptor Cable - 20Amp/3Pin Socket (WCM-20/10)
◊ Wavecom Mini Keyboard (+, +M Models Only) (WCM-Keyboard)
◊ Wavecom Log Book (WCM-Log-Book)
◊ Wavecom RCD Log Book (WCM-RCD-Log-Book)
◊ Wavecom Scanner (+, +M Models Only) (WCM-Scanner)
◊ HBC Fuse (WCM-HCB10AM205)
◊ RCD Isolation Transformer (WCM-ISOT)
◊ Probe Kit (WCM-Probe)
◊ Wavecom Thermal Transfer Printer (+, +M Models Only) (WCM-TT040-50)
◊ Wavecom Printer Labels (+, +M Models Only) (WCM-TAG-*colour*)
◊ Wavecom Printer Ribbons (+, +M Models Only) (WCM-Ribbon)
◊ WinPATS Premium (WCM-WinPATS Premium)
◊ WinPATS Extended Support (12 months) (WCM-WinPATS Support)
◊ Hard Transit Case (WCM-HTC)

Ordering Information
◊ TnT Unit @ 10 A with Leakage Test (WCM-TnT-EL)
◊ TnT Unit @ 10 A with Lithium Ion Battery and Leakage Test (WCM-TnT-ELB)
◊ TnT Unit @ 20 A with Leakage Test (WCM-TnT-ELX)
◊ TnT Unit @ 10 A with RCD, Leakage Test & Lithium Ion Battery (WCM-TnT-RCD)
◊ TnT Unit @ 20A with RCD, Leakage Test & Lithium Ion Battery (WCM-TnT-RCDX)
◊ TnT+ Unit @ 10 A with RCD & Leakage Test & Interface Connectivity (WCM-TnT+)
◊ TnT+ Unit @ same as TnT+ with 5000 Item Memory (WCM-TnT+M)
◊ TnT+ Unit @ same as TnT+M with 20 Amp operation (WCM-TnT+XM)

Contact us Distributed By
South Australia Victoria Western Australia
257 Grange Road Suite 8, 79-83 High Street, Unit 2/17 Casino Street,
Findon, SA 5023 Kew, VIC 3101 Welshpool, WA 6016
P: +61 08 8243 3500 P: +61 03 9897 4711 P: +61 08 9353 1943
F: +61 08 8243 3501 F: +61 08 8243 3501 F: +61 08 9353 4319
E: [email protected] E: [email protected] E: [email protected]

You might also like