Leaflet
Leaflet
2 TXD - - - TXD - G*
G* SD Card
B
3 RXD - - - RXD -
SD
Note: *Not applicable in HM107B-0000 model
4 - D+ - D+ - RXD+
24V 0V F*
5 GND GND GND GTi
SLAVE
COM1 COM2 HOST ETHERNET
6 - - D- - - TXD- E
7 RTS - - - RTS - A
C D
8 CTS - - - CTS - Touch screen display
9 - D- - D- - RXD-
HM110B-0000/ HM110B-N000
Note: HM104B-0000 & HM104B-N000 model consist only one DB9 port that supports RS232, RS422 and
RS485 levels on different pins. Please use a "Y" type cable with the pin information specified in the above (Front view) (Rear view)
table for simultaneous use of COM1 and COM2 port.
HM107B-0000, HM107B-N000, HM110B-0000, HM110B-N000 COM Port A Power Input (24VDC)
COM1 COM2 GIC B COM1 Port
COM Port Pin MODE1 MODE1 MODE2 C COM2 Port
EXPANSION 1 EXPANSION 2 EXPANSION 3 EXPANSION 4 EXPANSION 5
6 - D- - - - TXD-
B G*
SD
Note: *Not applicable in HM110B-0000 model
7 RTS - - - -
GTi 24V 0V F*
8 CTS - - - - -
SLAVE
COM1 COM2 HOST ETHERNET
9 - - - D- - RXD- E
Note: A C D
1. By default, the COM1 Port is set up for RS232 and RS485 connection. Touch screen display
2. COM2 port is set up by default for RS232. You can configure either RS485 or RS422 at a time for
communication
3. Mark “-” means connection is not required. 54LL001-00
Hardware Specifications: Mounting Dimensions (in mm): Installation steps:
Model HM104B-0000 HM104B-N000 HM107B-0000 HM107B-N000 HM110B-0000 HM110B-N000
HM104B-0000/ HM104B-N000 Step 1:
Nominal Supply voltage Un DC +24V (-15% to +20%) 36,5
136 Slide the HMI into panel cut out.
Power consumption (max.) 4W 4.5W 6W 6.5W 6.5W 7W 5,5 118,8
+1
-0.00 Note: While Installation, do not remove the gasket.
Over voltage category 2 GIC
-0.00
Backup battery life About 5 years or more at 25oC
+1
102
92
92,8
Panel type 4.3" TFT LCD (65535 colors) 7" TFT LCD (65535 colors) 10.1" TFT LCD (65535 colors)
Resolution 480 x 272 pixels 800 x 480 pixels 1024 x 600 pixels GTi
o
Back light LED backlight (half-life under room temperature 25 C > 20,000 hours)
(Panel Cutout)
Brightness 440 Cd/m2 400 Cd/m2 HM107B-0000/ HM107B-N000
36,5
CPU Cortex-M7 (600MHz) , 1284 DMIPS (2.14DMIPS/MHz) 207 5,5 +1
190
ROM 32MB 64MB 32MB 64MB 32MB 64MB
GIC
RAM 32MB 32MB 32MB 32MB 32MB 32MB
Step 2:
Touchscreen 4 wire resistive > 1,000,000 operated
Push the mounting clamps into their slots on the sides
134,2
+1
152,3
135
RTC Builtin 189,2 of the panel as shown below.
Accuracy of the real-time clock Typ. ± 2 sec/day @ ambient
USB 1 USB slave Ver 2.0; 1 USB host Ver 2.0 GTi
GIC
Cooling method Natural cooling
Mounting Flush with screw clamp
183,8
Mounting position Horizontal
203
+1
185
Panel cutout Dimensions (L) x (W) in mm 118.8 X 92.8 190 X 135 255 X 185 Step 3:
253,8
Dimensions (L) x (W) x (H) in mm 136 X 102 X 36.5 207 X 152.3 X 36.5 273 X 203 X 38 Tighten the clamp screws with the torque less than
GTi 0.4Nm. to avoid damage to the plastic case.
Terminal Type Pluggable Euro type terminal
(Torque:0.4 N.m. (3.5 lb.in) )
Screw tightening Torque 0.5 N.m. (4.4 lb.in) (Panel Cutout)
Weight Approx. 230g Approx. 250g Approx. 460g Approx. 480g Approx. 940g Approx. 960g Terminal Torque & Capacity:
Degree of Protection IP 65 Type Wire gauge (AWG) Stripped length Torque
Pollution Degree 2 Solid 28 - 12 7- 8 mm 0.4 N.m (3.5 Lb.in)
Operation temperature 0°C to +50°C Stranded 28 - 12 7- 8 mm Ø 3.5 0.4 N.m (3.5 Lb.in)
Storage temperature -20°C to +60°C
Operating environment 10% to 95% RH non-condensing Installation and Wiring:
Maximum operating Altitude Operation: 2000 m ; Transport: 0 - 3000 m Precautions: :
Ÿ Power off: Before starting the installation, ensure that the power to the panel is turned OFF.
Vibration resistance Conforms to IEC61131-2: continuous vibration 5 Hz - 8.3 Hz with amplitude 3.5 mm; 8.3 Hz - 150 Hz Ÿ Proper installation of the HMI into the panel is crucial to avoid potential issues such as reduced HMI’s life-span, short
with amplitude 1G
circuits or other failures that may arise from incorrect or insufficient Installation.
Shock resistance Conforms to IEC60068-2-27:11 ms, 15 G Peak, in X, Y, Z directions each for 6 times Ÿ Ensure that the ventilation openings are not obstructed and leave sufficient space around the HMI for proper airflow.
Ÿ Mounting panel thickness must be less than or equal to 5mm. E-Waste Regulatory notice:
Approvals CE and RoHs
Ÿ Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive or Kindly treat, recycle or dispose of this equipment
*COM1 port RS232 supports flow control RTS-CTS rain, excessive heat, regular impact shocks or excessive vibration. in an environmentally sound manner after End of
Life, as per WEEE (Waste Electrical and Electronic
*While inserting/removing SD card or USB Host, power should be turned off. Grounding: when wiring the power connector please refer to the Equipment) regulations; or as per local norms; or
following diagram. Connect the device to a regulated
Operating Environment: Screen Calibration: To ensure the best grounding for electric equipment, power source in the event of voltage fluctuations or
hand it over to General Industrial Ltd, through
website https://www.gicindia.com/get-in-touch/
The minimum system requirements for running the ‘GIC studio’ Step 1: First power off device. it is recommended to individually connect each functional WARNING non-compliance with voltage power supply
ground point to the earth of the system, keeping them specifications. www.gicindia.com
software are: Step 2: Touch & hold exact center of screen & then power on device.
1. Processor: 2GHz or equivalent processor separate from other high-power system.
Step 3: After power on, calibration screen will be appears.
2. Operating system: windows 10, 11. Step 4: Plus sign(+) will get appear touch that sign at middle intersection
3. Hard disc: 20GB Refer below image for the grounding marked terminal
point with (pointed stick) stylus. which is provided on unit.
4. RAM: 4GB and above.
5. Display: supports 1024 x 768 solution for full-color display Step 5: After that 2nd + sign appears, touch that sign at middle
intersection point with (pointed stick) stylus.
Software Installation: Step 6: At last 3rd + Sign Appears. When user touches 3rd + sign, then
"Screen Calibration done" message will appear on screen.
1. Download the GIC Studio software for GIC HM1 series and the user Step 7: After completion of this calibration process the previously
manual through the website http://www.gicindia.com, downloaded application in HMI will appear on screen. 24V
2. After downloading, extract the software installation files and then run 0V
the ‘GIC Studio.msi’ file. Note : User have to perform this steps very quickly. DC+
Earth
24V DC-
Note:
Ÿ It is recommended to use isolated power supply .
0V
Ÿ HMI can be used with other industrial automation equipment. To ensure safety, Please thoroughly read this manual and follow the provided
instructions during installation.
Ÿ The technical information provided in this document was correct at the time of publish.
Ÿ Product innovation being a continuous process, we reserve the right to alter specifications without any prior notice.
54LL001-00