C8 column have shorter alkyl chain (8 carbon atoms) compared to C18 column (18 carbon atoms). Therefore, C8 column is more polar than C18 column and can retain more polar compounds compared to C18. C8 is generally used for separation of more polar compounds whereas C18 is used for less polar compounds.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views7 pages

Analytical Chemistry Interview Questions and Answers 676

C8 column have shorter alkyl chain (8 carbon atoms) compared to C18 column (18 carbon atoms). Therefore, C8 column is more polar than C18 column and can retain more polar compounds compared to C18. C8 is generally used for separation of more polar compounds whereas C18 is used for less polar compounds.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Analytical Chemistry Interview

Questions And Answers Guide.

Global Guideline.
https://globalguideline.com/
Analytical Chemistry Interview Questions And Answers

G
Analytical Chemistry Job Interview Preparation Guide.
lo
ba
lG
Question # 1
What is heavy water?
ui
Answer:-
Isotopes of H2O, D2O
Read More Answers.
de
Question # 2
WHAT IS USE OF ION PAIR REAGENTS?
lin
Answer:-
The chemical substances that pair each other, to form
complexes. These can use for stabilization of one of the
molecule that is more active or to colorifying etc.
e
Read More Answers.

Question # 3
.C
How to establish relative response factor for hplc.
why it is required?
Answer:-
Actually RRF establishment required For Relatives Substances
O
Why because in Rs Sample having so many components like impurities,Degradents and main Analytes etc..so all components does not have same wavelength but we
are fix one particular wavelength for all peaks. so inthat wavelength some peak response high and some peak response low.so that reason only we are established
RRF and impurities also expensive so every time we can't purchase.so once established the RRF that factor used for RS calculation
M
Read More Answers.

Question # 4
What is Standard deviation?
Answer:-
Standard deviation tells about the widely spread out of the
measured analytical data points. Highly precised
measurements are less standard deviation.
Read More Answers.

Question # 5
How to calculate signal to noise ratio by this formula 2H/h where h from where and how to measure?
Answer:-
The H is the height of the main peak and the h is the lowest
height of a peak in the range of X5 the main peak (around
the amin peak)
Read More Answers.

Question # 6
WILL YOU DRY DST BEFORE FACTOR DETERMINATION BY USING KARL FISHER TITRATOR?
Answer:-
NO
Read More Answers.

Copyright © https://globalguideline.com Page 2/7


Analytical Chemistry Interview Questions And Answers

Question # 7
What is the difference between chromatographic purity and related substances?
Answer:-
Purity is only area normalization.
Rs is calculated by using std and rrf
Read More Answers.
G
Question # 8
In rs method development when we are going area normalization method to dilute standard method?
lo
Answer:-
When analyte gives linear response then only we can use area normalization. When analyte response is to high and saturated in chromatograph, for this condition we
ba
can use diluted standard.
Read More Answers.

Question # 9
lG
What is similarity factor and its use in api strength?
Answer:-
it is having both regulatory and domestic markets
Read More Answers.
ui
Question # 10
What is deference between the working standard and reference standard?
de
Answer:-
Reference std is like USP,EP std , in this std we get COA
including results of Potency by HPLC , NMR & XRPD data.
whenever there is requirement of w.std preparation first we
lin
have get API rawmaterial from warehouse & we check assay ,
water content or LOD & Related substances aganist reference
std . Some times we are doing analysis in duplicate & get
mean value.then we decide final assay or potency value &
e
it's validity one year
Read More Answers.
.C
Question # 11
What is rs test why we are perfoming rs test?
Answer:-
RS stands for related substance, means by-products upon
O
completion of reaction, or the unreacted portion present in
the product. RS testing help us to identify the adequate
quantitiy of these by-products or unreacted part.
M
More over RS help us during the stability study to know any
significant change in the nature of product during long
storage in various climatic conditions
Read More Answers.

Question # 12
What is use of acetonitrile compare to methanol in RP-HPLC Method development?
Answer:-
ACN is highly polar as compare to Methanol So provide Better
resolution for many compound and it has property to form
hydrogen bond so provide better selectivity.
Read More Answers.

Question # 13
Explain What is a base line?
Answer:-
#Base line is nothing but the detectors response to the
mobile phase.(gc,hplc)
#Base line should be stable to start a run.
#Un stabilized base line is called as base line noise.
#Base line noise is of many types..
1)Cyclic base line
2)Synchorinise noise
3)Asynchorinise noise
4)Base line drift
5)Spikes
6)Negative peaks

Copyright © https://globalguideline.com Page 3/7


Analytical Chemistry Interview Questions And Answers

7)No peaks
#Base line noise is attributed due to mobile phase,sample,
system problems.leaks in the system,temperature variations
in lab etc..
Read More Answers.

Question # 14
G
IN pH CALIBRATION,CALIBRATION IS DONE FOR pH METER OR ELECTRODE?HOW WILL YOU JUDGE THAT THE METER TO BE CALIBRATED
WITH 4,7,9.2 BUFFERS?EXPLAIN TEMPERATURE EFFECTS ON pH?
lo
Answer:-
calibration is also one of the system
suitability test,whether the system working satisfactory or
not physically so when you do the calibration for pH meter
ba
with standard pH buffer solution (which is from NIST-it may
accurate solution for actual pH)and once if your instrument
has calibrated,you can cross verify your insrument against
those pH buffer solution (NIST) and the acceptable range is
lG
+/- 0.02 then you can conclude for ?
once if temperature raises the pH will decrease and its not
all cases
Read More Answers.
ui
Question # 15
Why karl fisher factor is 5 ?
Answer:-
de
5 mg of water consuming 1 ml of KF reagent.
Read More Answers.
lin
Question # 16
Suppose we prepared pH buffer solution in lab.and calibrate against NIST solution, and same shall going to used upto 30 days. is it possible to stable pH and
apperance? suggest?
Answer:-
e
pH OF THE BUFFER SOLUTION WILL BE CHANGE, AS DUE TO PRESENCE OF NITROGEN CONTAINING SUBSTANCES AND ALSO DUE TO
MICROBIAL GROWTH. BUT IF STORED AT 4 DEGREE CENTI. IT MAY USED TO SOME EXTENT.
Read More Answers.
.C
Question # 17
What is difference between silica used in TLC and HPLC column?
Answer:-
O
Tlc is called thin layer chromatography. The simple technique works on the principle of adsorption, where as HPLC is a sophisticated technique works on partition
principle.
M
Read More Answers.

Question # 18
What is quality controle?
Answer:-
quality control means to maintain the quality of product by
calculating their content ,different physical parameters,as
per their specification IP/BP/USP/EP/JP
Read More Answers.

Question # 19
When we get Moisture content by KF higher than by LOD, what does this indicate?
Answer:-
KF titration is the most accurate method in analysing
moisture content. But it is coastlier and maintaince is too
high. So in analysis of moisture content an alternative
experiment is Loss on Drying(LOD), which gives approximate
moisture value present in the given substance.
Read More Answers.

Question # 20
Why are use silicon oil mr?
Answer:-
I DO NOT KNOW
Read More Answers.

Copyright © https://globalguideline.com Page 4/7


Analytical Chemistry Interview Questions And Answers

Question # 21
What is the difference between c8 and c18 hplc column?
Answer:-
C8 column have more polar than C18. and it has 8 carbon atoms.
Read More Answers.
G
Question # 22
How can we detect a compound in hplc which does not have any chromofore?
lo
Answer:-
That sample converted chromofore by derivitisation technique and going to analysis
Read More Answers.
ba
Question # 23
In the gas chromatography what is used carrier gasand make up gas?
lG
Answer:-
nitrogen
Read More Answers.
ui
Question # 24
How we choose the mobile phase for method development..?
Answer:-
de
it depend on the solubility of analyte whether it is soluble in polar or non polar solvent apart from that retention time, capacity factor to prepare suitable mobile phase.
Read More Answers.

Question # 25
lin
How to calibration of the uv spectroscopy and its test?
Answer:-
Just you want to know about that please just refer your SOP (STANDARD OPERATING PROCEDURE)
e
Read More Answers.

Question # 26
.C
How do we fix the sample concentaryion in hplc method development. what is the basis?
Answer:-
IF ALL IMPURTITIES AT SPEC LEVEL ARE MEETING S/N RATIO MORE
THAN 60 AT THAT PARTICULAR CONCENTRATION AS WEL AS NO
O
COLUMN OVERLOAD.
Read More Answers.
M
Question # 27
How to know HPLC column performance?
Answer:-
Check for the number of plates that it maintains stady all
over the run , check the SST at avery run that cpmplies the
acceptance criterias of the method.
Read More Answers.

Copyright © https://globalguideline.com Page 5/7


Chemistry Most Popular Interview Topics.

1 : General Chemistry Frequently Asked Interview Questions and Answers Guide.

2 : Organic Chemistry Frequently Asked Interview Questions and Answers Guide.

3 : Inorganic Chemistry Frequently Asked Interview Questions and Answers Guide.

4 : Physical Chemistry Frequently Asked Interview Questions and Answers Guide.

5 : Nuclear Chemist Frequently Asked Interview Questions and Answers Guide.

6 : Nuclear scientist Frequently Asked Interview Questions and Answers Guide.

7 : Enologist Frequently Asked Interview Questions and Answers Guide.


About Global Guideline.

Global Guideline is a platform to develop your own skills with thousands of job interview questions
and web tutorials for fresher's and experienced candidates. These interview questions and web
tutorials will help you strengthen your technical skills, prepare for the interviews and quickly revise
the concepts. Global Guideline invite you to unlock your potentials with thousands of Interview
Questions with Answers and much more. Learn the most common technologies at Global Guideline.
We will help you to explore the resources of the World Wide Web and develop your own skills from
the basics to the advanced. Here you will learn anything quite easily and you will really enjoy while
learning. Global Guideline will help you to become a professional and Expert, well prepared for the
future.

* This PDF was generated from https://GlobalGuideline.com at November 29th, 2023

* If any answer or question is incorrect or inappropriate or you have correct answer or you found any
problem in this document then don't hesitate feel free and e-mail us we will fix it.

You can follow us on FaceBook for latest Jobs, Updates and other interviews material.
www.facebook.com/InterviewQuestionsAnswers

Follow us on Twitter for latest Jobs and interview preparation guides


https://twitter.com/InterviewGuide

Best Of Luck.

Global Guideline Team


https://GlobalGuideline.com
[email protected]

You might also like