MS-LWS en
MS-LWS en
Key features
Service unit components of the MS series
Solutions for every application Freely combinable function modules
With its large product range, highly ef- application-specific combinations or Pressure regulators, on/off and soft- bled when replacing individual mod-
fective components and a wide choice complete turnkey solutions. The five start valves with safety function, filters, ules.
of functions, the MS series from Festo sizes in the MS series achieve maxi- pressure and flow sensors, dryers, Many of the components are also UL
offers a complete concept for com- mum flow rates with low space require- sensors and lubricators can be assem- and ATEX certified.
pressed air preparation. It is suitable ments. bled into a suitable solution for every
for simple standard applications as task. The modular structure enables
well as application-specific solutions the components to be combined as re-
with very high quality requirements. quired. The simple connection system
Available as individual components, saves time because the entire combi-
pre-assembled combinations ex-stock, nation doesn't need to be disassem-
Convenient tools for planning and se- Selection tool for choosing the right
lecting application-specific individual combination of service unit compo-
components and combinations. The nents without oversizing, and with the
product configurator can be used to right air purity class:
configure customised solutions quickly a www.festo.com/engineering/
and to transfer the order data without service unit
any hassle.
• Maximum machine availability • Fast and reliable exhausting of sys- • Fully automatic monitoring and reg- • Optimum flow rate with a size that is
thanks to controlled processes tems up to Performance Level e, cer- ulation of compressed air supply up to 18% smaller
• Reliable compressed air preparation tified to EN ISO 13849-1 • Automatic shut-off of the com- • Excellent energy efficiency
and supply for systems • Integrated soft-start function pressed air in stand-by mode • Cost-optimised combinations – save
• Integrated or stand-alone • Detection and notification of leakag- up to 30%!
• Easy to connect with M8/M12 plug es
• Condition monitoring of relevant
process data
Size differences
Size MS2 MS4 MS6 MS9 MS12
Grid dimension [mm] 25 40 62 90 124
Connection sizes M5, QS-6 G1/8, G1/4, G3/8 G1/4, G3/8, G1/2, G3/4 G1/2, G3/4, G1, G1 1/4, G1, G1 1/4, G1 1/2, G2
G1 1/2
Standard nominal flow rate qnN1) [l/min] 350 1800 6500 20000 22000
Key features
Note
Information
The next few pages provide a brief You can find detailed information and Accessories such as connecting plates
overview of the product range for the all the technical data in the documen- or mounting brackets can be ordered
MS series service unit components. tation for the relevant service unit com- either via the configurator or separate-
ponent. ly.
The order of the individual service unit The configurator for the service unit • Regulators MS-LFR/LR/LRP are only • A micro filter MS-LFM must be in-
components within a combination is MSB is a reliable and convenient way permissible in the flow direction stalled in the flow direction up-
relevant for safety and functionality. of arranging individual service unit with the same or decreasing pres- stream of an activated carbon filter
The service unit components cannot be components and ensures compliance sure regulation range MS-LFX or membrane air dryer
combined in any order in the flow di- with the applicable rules. As a result, • Filters MS-LFR/LF/LFM/LFX are only MS-LDM1
rection. They are subject to restrictions you get a fully assembled unit, includ- permissible in the flow direction • A flow sensor SFAM cannot be in-
and rules. ing UL or ATEX certification, if neces- with an increasing grade of filtration stalled directly downstream of a reg-
sary. • Lubricators MS-LOE are not permit- ulator MS-LFR/LR; a branching mod-
When combining a unit from individu- ted in the flow direction upstream of ule MS-FRM must be positioned be-
ally configured and ordered service a filter MS-LFR/LFM/LF/LFX, water tween them
unit components, the following points separator MS-LWS or membrane air • A soft-start/quick exhaust valve
must be adhered to under all circum- dryer MS-LDM1 MS-SV must be the last service unit
stances. component in the flow direction
Freely configurable combi- 4 – – 1/8, 1/4 – 1/8, 1/4, 3/8 1/8, 1/4, 3/8
nations 6 – – 1/4, 3/8, 1/2 – 1/4, 3/8, 1/2, 3/4 1/4, 3/8, 1/2, 3/4
9 – – 3/4, 1 3/4, 1 1/2, 3/4, 1, 1 1/4, 1 1/2 1/2, 3/4, 1, 1 1/4, 1 1/2
Key features
Product range for service unit components of the MS series
Type Description Size Pneumatic connection
Push-in Female thread Connecting plate with thread
connector M G NPT G NPT
Individual devices
Filter regulators MS-LFR Datasheets a Internet: ms2-lfr; ms4-lfr; ms6-lfr; ms9-lfr; ms12-lfr
Filter and pressure regula- 2 QS-6 M5 – – – –
tor in a single device, grade 4 – – 1/8, 1/4 – 1/8, 1/4, 3/8 1/8, 1/4, 3/8
of filtration 5 or 40 µm 6 – – 1/4, 3/8, 1/2 – 1/4, 3/8, 1/2, 3/4 1/4, 3/8, 1/2, 3/4
9 – – 3/4, 1 3/4, 1 1/2, 3/4, 1, 1 1/4, 1 1/2 1/2, 3/4, 1, 1 1/4, 1 1/2
12 – – – – 1, 1 1/4, 1 1/2, 2 –
Fine and micro filters MS-LFM Datasheets a Internet: ms4-lfm; ms6-lfm; ms9-lfm; ms12-lfm
Grade of filtration 0.01 or 4 – – 1/8, 1/4 – 1/8, 1/4, 3/8 1/8, 1/4, 3/8
1 μm 6 – – 1/4, 3/8, 1/2 – 1/4, 3/8, 1/2, 3/4 1/4, 3/8, 1/2, 3/4
9 – – 3/4, 1 3/4, 1 1/2, 3/4, 1, 1 1/4, 1 1/2 1/2, 3/4, 1, 1 1/4, 1 1/2
12 – – – – 1, 1 1/4, 1 1/2, 2 –
Activated carbon filters MS-LFX Datasheets a Internet: ms4-lfx; ms6-lfx; ms9-lfx; ms12-lfx
For removing liquid and 4 – – 1/8, 1/4 – 1/8, 1/4, 3/8 1/8, 1/4, 3/8
gaseous oil particles 6 – – 1/4, 3/8, 1/2 – 1/4, 3/8, 1/2, 3/4 1/4, 3/8, 1/2, 3/4
9 – – 3/4, 1 3/4, 1 1/2, 3/4, 1, 1 1/4, 1 1/2 1/2, 3/4, 1, 1 1/4, 1 1/2
12 – – – – 1, 1 1/4, 1 1/2, 2 –
Key features
Product range for service unit components of the MS series
Type Description Size Pneumatic connection
Push-in Female thread Connecting plate with thread
connector M G NPT G NPT
Individual devices
Pressure regulators MS-LR Datasheets a Internet: ms2-lr; ms4-lr; ms6-lr; ms9-lr; ms12-lr
For setting the required op- 2 QS-6 M5 – – – –
erating pressure, 4 – – 1/8, 1/4 – 1/8, 1/4, 3/8 1/8, 1/4, 3/8
4 pressure regulation rang- 6 – – 1/4, 3/8, 1/2 – 1/4, 3/8, 1/2, 3/4 1/4, 3/8, 1/2, 3/4
es 9 – – 3/4, 1 3/4, 1 1/2, 3/4, 1, 1 1/4, 1 1/2 1/2, 3/4, 1, 1 1/4, 1 1/2
12 – – – – 1, 1 1/4, 1 1/2, 2 –
Key features
Product range for service unit components of the MS series
Type Description Size Pneumatic connection
Push-in Female thread Connecting plate with thread
connector M G NPT G NPT
Individual devices
On/off valves MS-EM Datasheets a Internet: ms4-em; ms6-em; ms9-em; ms12-em
Manually actuated on/off 4 – – 1/8, 1/4 – 1/8, 1/4, 3/8 1/8, 1/4, 3/8
valve for pressurising and 6 – – 1/4, 3/8, 1/2 – 1/4, 3/8, 1/2, 3/4 1/4, 3/8, 1/2, 3/4
exhausting pneumatic sys- 9 – – 3/4, 1 3/4, 1 1/2, 3/4, 1, 1 1/4, 1 1/2 1/2, 3/4, 1, 1 1/4, 1 1/2
tems. 12 – – – – 1, 1 1/4, 1 1/2, 2 –
Key features
Product range for service unit components of the MS series
Type Description Size Pneumatic connection
Push-in Female thread Connecting plate with thread
connector M G NPT G NPT
Individual devices
Membrane air dryers MS-LDM1 Datasheets a Internet: ms4-ldm; ms6-ldm
Wear-free membrane dryer 4 – – 1/8, 1/4 – 1/8, 1/4, 3/8 1/8, 1/4, 3/8
with internal air consump- 6 – – 1/4, 3/8, 1/2 – 1/4, 3/8, 1/2, 3/4 1/4, 3/8, 1/2, 3/4
tion
Peripherals overview
Water separator MS6-LWS
4
-H- Note
1 Additional accessories:
• Module connector for combination
6 2 with size MS4/MS6 or size MS9
a Internet: amv, rmv, armv
3 • Adapter for mounting on profiles
a Internet: ipm-80, ipm-40-80,
5 ipm-80-80
1
5/6
1) Module connector MS6-MV [5] or mounting bracket MS6-WP/WPB/WPE/WPM [6] is required for mounting.
Type codes
001 Series 007 Condensate drain
MS MS series V Automatic
E2 External fully automatic condensate drain, electric, 110 V AC, termi-
002 Size nals
6 Grid dimension 62 mm E3 External fully automatic condensate drain, electric, 230 V AC, termi-
nals
003 Thread type E4 External fully automatic condensate drain, electric, 24 V DC, terminals
G thread
008 Type of mounting
Datasheet
Fully automatic
condensate drain
-M- Flow rate
2400 ... 3800 l/min
-É- www.festo.com
The maintenance-free water separator • Constantly high condensate separa- • Available with fully automatic or ful- • Optional device variant EX4 for use
removes condensate from the com- tion (99%) up to the maximum flow ly automatic, electrically actuated in potentially explosive areas in
pressed air. rate condensate drain zones 1, 2, 21 and 22
• Metal bowl
-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.
Datasheet
Operating and environmental conditions
Condensate drain Fully automatic Fully automatic, electrically actuated
V E2/E3/E4
Operating pressure [bar] 2 ... 12 (2 ... 10)1) 0.8 ... 16 (0.8 ... 10)1)
Operating medium Compressed air to ISO 8573-1:2010 [7:–:–] Compressed air to ISO 8573-1:2010 [–:–:–]
Inert gases
Ambient temperature [°C] +5 ... +60 +1 ... +60
Temperature of medium [°C] +5 ... +60 +1 ... +60
Storage temperature [°C] –10 ... +60 +1 ... +60
Corrosion resistance class CRC2) 2
Food-safe3) See supplementary material information –
UL certification3) c UL us - Recognized (OL)
1) Value in brackets applies to MS6-LWS with UL certification.
2) More information www.festo.com/x/topic/crc
3) More information: www.festo.com/catalogue/ms-lws d Support/Downloads.
ATEX
EU certification [EX4]
ATEX category for gas II 2G
Type of (ignition) protection for gas Ex h IIC T6 Gb X
ATEX category for dust II 2D
Type of (ignition) protection for dust Ex h IIIC T60°C Db X
Explosion ambient temperature +5°C š Ta š +60°C
Explosion protection certification outside the EPL Db (GB)
EU EPL Gb (GB)
CE marking (see declaration of conformity)1) To EU Explosion Protection Directive (ATEX)
UKCA marking (see declaration To UK regulations for explosions
of conformity)1)
Weight [g]
Water separator 820
Water separator with fully automatic, electri- 1800
cally actuated condensate drain E2/E3/E4
Materials
Sectional view
Water separator
1 [1] Housing Die-cast aluminium
[2] Bowl Wrought aluminium alloy
Inspection window PA
– Seals NBR
Note on materials RoHS-compliant
LABS (PWIS) conformity VDMA24364-B1/B2-L
Datasheet
Standard flow rate qn as a function of differential pressure p1-2
MS6-LWS-1/4-... MS6-LWS-3/8-...
Pneumatic connection G1/4, NPT1/4 Pneumatic connection G3/8, NPT3/8
2 2
1.5 1.5
p1-2 [bar]
p1-2 [bar]
1 1
0.5 0.5
0 0
0 1000 2000 3000 4000 5000 0 1000 2000 3000 4000 5000 6000 7000 8000
qn [l/min] qn [l/min]
MS6-LWS-1/2-...
Pneumatic connection G1/2, NPT1/2
2
1.5
p1-2 [bar]
0.5
4 bar
0 6 bar
0 1000 2000 3000 4000 5000 6000 7000 8000
10 bar
qn [l/min] 14 bar
Datasheet
Dimensions – Basic version Download CAD data a www.festo.com
[V] Fully automatic condensate drain
a Flow direction
Type B1 B2 B3 D1 L1 L2 L4 L5
MS6-LWS-1/4-...-V G1/4
MS6-LWS-3/8-...-V 62 31 76 G3/8 220 42 88 64
MS6-LWS-1/2-...-V G1/2
-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.
Datasheet
Dimensions – Condensate drain Download CAD data a www.festo.com
[E2]/[E3]/[E4] Fully automatic, electrically actuated Datasheets a Internet: pwea
Type B6 B7 B8 B9 L12
MS6-LWS-...-E2/E3/E4 72 140 108 15 174.5
Ordering data
Integrated as metal bowl
Size Condensate drain Connection Part no. Type
MS6 Fully automatic G1/4 564868 MS6-LWS-1/4-U-V
G3/8 564869 MS6-LWS-3/8-U-V
G1/2 564870 MS6-LWS-1/2-U-V
[1] 1/4, 3/8, 1/2, AQN, AQP, AQR, AQS, E2, E3, E4, WPM
Not with EU EX4 certification.
[2] WP, WPM Only with connecting plate AGB, AGC, AGD, AGE, AQN, AQP, AQR or AQS.
, for Z
Peripherals overview
5
-H- Note
4
Additional accessories:
• Module connector for combination
3 with size MS6, MS9 or MS12
a Internet: rmv, armv
1
2/3/4/5
2/3/4/5
Type codes
001 Series 005 Bowl type
MS MS series U Aluminium
Datasheet
Fully automatic
condensate drain
-M- Flow rate
12000 ... 15000 l/min
The water separator removes conden- • Constantly high condensate separa- • Available with fully automatic or ful- • Optional device variant EX4 for use
sate from the compressed air. tion (99%) up to the maximum flow ly automatic, electrically actuated in potentially explosive areas in
rate condensate drain zones 1, 2, 21 and 22
• Metal bowl
-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.
Datasheet
Operating and environmental conditions
Condensate drain Fully automatic Fully automatic, electrically actuated
V E2/E3/E4
Operating pressure [bar] 2 ... 12 0.8 ... 16
Operating medium Compressed air to ISO 8573-1:2010 [–:–:–]
Ambient temperature [°C] +5 ... +60 +1 ... +60
Temperature of medium [°C] +5 ... +60 +1 ... +60
Storage temperature [°C] +5 ... +60 +1 ... +60
Corrosion resistance class CRC1) 2
UL certification2) c UL us - Recognized (OL)
1) More information www.festo.com/x/topic/crc
2) More information: www.festo.com/catalogue/ms-lws d Support/Downloads
ATEX
EU certification [EX4]
ATEX category for gas II 2G
Type of (ignition) protection for gas Ex h IIC T6 Gb X
ATEX category for dust II 2D
Type of (ignition) protection for dust Ex h IIIC T60°C Db X
Explosion ambient temperature +5°C š Ta š +60°C
Explosion protection certification outside the EPL Db (GB)
EU EPL Gb (GB)
CE marking (see declaration of conformity)1) To EU Explosion Protection Directive (ATEX)
UKCA marking (see declaration To UK regulations for explosions
of conformity)1)
Weight [g]
Water separator 2000
Water separator with fully automatic, electri- 2400
cally actuated condensate drain E2/E3/E4
Materials
Sectional view
1 Water separator
[1] Housing Die-cast aluminium
[2] Bowl Wrought aluminium alloy
Inspection window PA
3 [3] Spin disc POM
[4] Separating disc POM
– Covering Reinforced PA
– Connecting plate, module connector, mounting bracket Die-cast aluminium
2 – Seals NBR
Note on materials RoHS-compliant
4 LABS (PWIS) conformity VDMA24364-B1/B2-L
Datasheet
Standard flow rate qn as a function of differential pressure Δp1–2
Pneumatic connection G3/4, NPT3/4 Pneumatic connection G1, NPT1
4 bar 10 bar
6 bar 12 bar
a Flow direction
Type B1 B2 B3 L1 L2 L4 L5 L6
MS9-LWS-G 90 45 109 310.5 62 120 50 34.5
Datasheet
Dimensions – Connecting thread/connecting plate Download CAD data a www.festo.com
With female thread With connecting plate AG.../AQ...
[2] Retaining screw M6xmin. 90 to DIN 912 (not included in the scope of deliv- [3] Earthing screw M4x8 (only with a Flow direction
ery) for wall mounting without mounting bracket MS9-...-EX4)
Type B4 B5 B6 B7 B8 D1 D4 D5 L7 L8 T1 ß
EX4 EX4
MS9-LWS-3/4 G3/4
90 104 91.5 – – – 11 6.5 66 – 6 –
MS9-LWS-1 G1
MS9-LWS-AGD 132 G1/2 30
MS9-LWS-AGE 132 G3/4 36
MS9-LWS-AGF – – – 112 122 142 G1 – – – 35 – 41
MS9-LWS-AGG 162 G1 1/4 50
MS9-LWS-AGH 176 G1 1/2 55
MS9-LWS-N3/4 NPT3/4-14
90 104 91.5 – – – 11 6.5 66 – 6 –
MS9-LWS-N1 NPT1-11 1/2
MS9-LWS-AQR 132 NPT1/2-14 30
MS9-LWS-AQS 132 NPT3/4-14 36
MS9-LWS-AQT – – – 112 122 142 NPT1-11 1/2 – – – 35 – 41
MS9-LWS-AQU 162 NPT1 1/4-11 1/2 50
MS9-LWS-AQV 176 NPT1 1/2-11 1/2 55
-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.
Datasheet
Dimensions – Condensate drain Download CAD data a www.festo.com
[V] Fully automatic
Type B1 D1 H1 L1 L2 L3
MS9-LWS-...-V – 5.6 34.5 – – –
MS9-LWS-...-E2/E3/E4 72 – 178 140 108 15
Ordering data
Size Condensate drain Connection Part no. Type
MS9 Fully automatic – 571468 MS9-LWS-G-U-V
1) 3/4, 1, N3/4, N1, AQR, AQS, AQT, AQU, AQV, G, E2, E3, E4, WPM
Not with EU EX4 certification
2) WP, WPM, WPB Not with pneumatic connection G
Im
Peripherals overview
2 3
-H- Note
Additional accessories:
• Module connector for combination
1 with size MS9
2 3
a Internet: armv
1 2/3
2/3
Type codes
001 Series 005 Bowl type
MS MS series U Aluminium
AGF Sub-base G1
007 Type of mounting
AGG Sub-base G11/4
Without mounting bracket
AGH Sub-base G11/2
WP Mounting bracket basic design
AGI Sub-base G2
AQT Sub-base NPT1
008 Flow direction
AQU Sub-base NPT11/4
Flow direction from left to right
AQV Sub-base NPT11/2
Z Flow direction from right to left
AQW Sub-base NPT2
G Module without connecting thread, without sub-base
Datasheet
Fully automatic
condensate drain
-M- Flow rate
25000 l/min
The water separator removes conden- • Constantly high condensate separa- • Available with fully automatic or ful-
sate from the compressed air. tion (99%) up to the maximum flow ly automatic, electrically actuated
rate condensate drain
• Metal bowl
-H- Note: This product conforms to ISO 1179-1 and ISO 228-1.
Flow rates
Standard nominal flow rate qnN1) [l/min] 25000 ±15%
Max. standard flow rate [l/min] 40000 ±15%
qn max.
Datasheet
Operating and environmental conditions
Condensate drain Fully automatic Fully automatic, electrically actuated
V E2/E3/E4
Operating pressure [bar] 2 ... 12 0.8 ... 16
Operating medium Compressed air to ISO 8573-1:2010 [–:–:–]
Ambient temperature [°C] +5 ... +60 +1 ... +60
Temperature of medium [°C] +5 ... +60 +1 ... +60
Storage temperature [°C] +5 ... +60 +1 ... +60
Corrosion resistance class CRC1) 2
Weight [g]
Water separator 6300
Water separator with fully automatic, electri- 7000
cally actuated condensate drain E2/E3/E4
Accessories
Connecting plate AG... 1300
Mounting bracket WP 700
Materials
Sectional view
Water separator
1 [1] Housing Die-cast aluminium
[2] Bowl Wrought aluminium alloy
Inspection window PA
[3] Spin disc POM
[4] Separating disc POM
3 – Covering Reinforced PA
– Connecting plate, module connector, Die-cast aluminium
mounting bracket
2 – Seals NBR
Note on materials RoHS-compliant
LABS (PWIS) conformity VDMA24364-B1/B2-L
Datasheet
Standard flow rate qn as a function of differential pressure Δp1–2
MS12-LWS 1.5 und 2
Pneumatic connection G1 1/2, G2, NPT1 1/2, NPT2
0.8
p1-2 [bar]
0.6
0.4
0.2
0
0 10000 20000 30000 40000
qn [l/min]
4 bar 10 bar
6 bar 12 bar
-H- Note
Dimensions with
• Connecting plate a ms12-ag
• Mounting bracket a ms12-wp
a Flow direction
Type B1 B2 B3 B4 L1 L2 L4 L5 L6 ß1
MS12-LWS-G 124 122 61 148 441 85 165 60 36 36
Datasheet
Dimensions – Condensate drain Download CAD data a www.festo.com
Fully automatic V
Type B1 D6 H1 L1 L2 L3 L6
MS12-LWS-...-V – 5.6 – – – – 36
MS12-LWS-...-E2/E3/E4 72 – 179 140 108 15 –
Ordering data
Size Condensate drain Connection Part no. Type
MS12 Fully automatic – 8005550 MS12-LWS-G-U-V