Midterm Exam
Midterm Exam
EE 413- EE Electives 1
Midterm Examination (Middle term, SY 2022-2023)
2.Heavy current fuses have wires that are _________ in diameter than
smaller ones:
A. Larger
B. Smaller
C. Same
D. Any of above
8.In a circuit breaker the arcing contacts are made of which material:
A. Porcelain
B. Tungsten alloy
C. Electrolytic copper
D. All of these
14. Generally the main contacts of circuit breaker are constructed of:
A. Softer alloy
B. Harder alloy
19. A major short circuit fault when uncleared could ultimately lead
to:
A. Blowing of fuse
B. Fire
C. Generation of harmonics
D. High voltage drops
34.In star connected system, without neutral ground, the zero sequence
currents equal:
A. RMS value of phase currents
B. Peak value of phase currents
C. Zero
63. The basic requirement of any power system protection scheme is:
A. Selectivity
B. Stability
C. Speed
D. All of these
69. The modern electrical power systems are more likely to use:
A. Electromechanical relays
B. Static analog relays
C. Static digital relays
D. None of these
70. Air circuit breakers can be used for current values up to:
A. 3000 A
B. 6000 A
C. 18000 A
D. 32000 A
71. The protection system which compares the current entering and
leaving the protection zone:
A. Different protection system
B. Integral protection system
C. Back protection system
D. Subtraction protection system
79. Statement: SF6 circuit breakers have very short arcing time.
81. Utterance: SF6 circuit breakers are costly.
A. Both statement and utterance are correct
B. Both are wrong
C. The statement is correct, the utterance is wrong
D. The statement is wrong, the utterance is correct
82. Plug setting multiplier is defined as the ratio of:
A. Fault current in relay coil x Pick up current
B. Fault current in relay coil / Pick up current
C. Fault current in relay coil x Transformer secondary turns
D. Fault current in relay coil / Transformer secondary turns
86. The major advantage associated with the static digital relay is:
A. Less sensitive
B. Performance speed is slow
C. It is expensive
D. It is not accurate
90. The __________ the current, the ___________ is the time required
by fuse to blow up:
A. Greater, smaller
B. Greater, Greater
C. Smaller, Smaller
D. All of these are possible
96. The Insulation test voltage should be done with the parameters:
A. 2 kV, 50 Hz, 1 min
B. 5 kV, 50 Hz, 5 min
C. 10 kV, 50 Hz, 10 min
D. 20 kV, 50 Hz, 20 min
111. The term effective earthing refers to the earthing which is done
through:
A. Resistance
B. Reactance
C. Transformer
D. None of these
115. The extent of damage and injuries caused due to a shock depends
on:
A. Amount of current
B. Path of the current
C. Time for which current flows
D. All of these
118. The correct statement about the cross-section area of the arc and
the resistance:
A. The arc resistance increases with the increase of cross-
section area
B. The arc resistance increases with the decrease of cross-
section area
C. Both are not related to other
D. None of above
126. For safe operations, the transformer oil should have a minimum
dielectric strength of:
A. 10 KV
B. 20 kV
C. 50 kV
D. 100 KV
133. A power system contains two relays of 5 VA and 10 VA. The correct
statement about the sensitivity of relays:
A. 5 VA relay is more sensitive than 10 VA
B. 10 VA relay is more sensitive than 5 VA
C. Both are equally sensitive
D. One can’t determine sensitivity from VA
140. The correct relationship between the fusing current and diameter
of the wire is:
A. I = k d
B. I = k d1.5
C. I = k d2
D. I = k d3
141. The basic function of a relay is to:
A. Detect the fault
B. Interrupt the circuit
C. Both of these
D. None of these
142. A three phase 1000 MVA circuit breaker, 11 kVA has symmetrical
breaking current:
A. 90909 A
B. 11000 A
C. 52486 A
D. 44088 A
148. The air which is preferred for air blast circuit breakers:
A. Moisture free air
B. Air with 50% nitrogen
C. Air with 25% hydrogen
D. Air with higher moisture content
197.In HRC fuse, the time between cut-off and final current zero is
termed:
A. Arcing time
B. Pre-arcing time
C. Total operating time
D. None of these
201.The least expensive protection for low voltage power system is:
A. Fuse
B. Circuit breaker
C. Isolator
D. SF6 breaker
234.If fault occurs near the impedance relay, the VII ratio will be
A. Constant for all distances
B. Higher than that of if fault occurs away from the relay
C. Lower than that of if fault occurs away from the relay
D. None of these
243.For cost and safety, the outdoor substations are installed for
voltages beyond
A. 11 kV
B. 110 kV
C. 33 kV
D. 60 kV
249.The medium used for the extinction of arc in air circuit breaker
A. Air
B. Oil
C. SF6
D. Water