Simulation 4kWc
Simulation 4kWc
Author
Project: Nouveau Projet
Variant: Nouvelle variante de simulation
PVsyst V7.2.8
VC0, Simulation date:
26/01/24 16:36
with v7.2.8
Project summary
Geographical Site Situation Project settings
Kébili Latitude 33.71 °N Albedo 0.20
Tunisia Longitude 8.97 °E
Altitude 44 m
Time zone UTC+1
Meteo data
Kébili
Meteonorm 8.0 (1991-2000), Sat=100 % - Synthétique
System summary
Grid-Connected System No 3D scene defined, no shadings
System information
PV Array Inverters
Nb. of modules 10 units Nb. of units 1 Unit
Pnom total 4000 Wp Pnom total 3800 W
Pnom ratio 1.053
Results summary
Produced Energy 3880 kWh/year Specific production 970 kWh/kWp/year Perf. Ratio PR 78.06 %
Table of contents
Project and results summary 2
General parameters, PV Array Characteristics, System losses 3
Main results 4
Loss diagram 5
Special graphs 6
PVsyst V7.2.8
VC0, Simulation date:
26/01/24 16:36
with v7.2.8
General parameters
Grid-Connected System No 3D scene defined, no shadings
PV Field Orientation
Orientation Sheds configuration Models used
Fixed plane No 3D scene defined Transposition Perez
Tilt/Azimuth 30 / 180 ° Diffuse Perez, Meteonorm
Circumsolar separate
PV Array Characteristics
PV module Inverter
Manufacturer ALPHANIS.S.A Manufacturer Growatt New Energy
Model ALPHANIS ALPHA-N Model MIN 3800TL-XH-US
(Custom parameters definition) (Original PVsyst database)
Unit Nom. Power 400 Wp Unit Nom. Power 3.80 kWac
Number of PV modules 10 units Number of inverters 1 unit
Nominal (STC) 4000 Wp Total power 3.8 kWac
Modules 1 String x 10 In series Operating voltage 50-550 V
At operating cond. (50°C) Pnom ratio (DC:AC) 1.05
Pmpp 3613 Wp
U mpp 273 V
I mpp 13 A
Array losses
Thermal Loss factor DC wiring losses Module Quality Loss
Module temperature according to irradiance Global array res. 340 mΩ Loss Fraction -0.3 %
Uc (const) 20.0 W/m²K Loss Fraction 1.5 % at STC
Uv (wind) 0.0 W/m²K/m/s
PVsyst V7.2.8
VC0, Simulation date:
26/01/24 16:36
with v7.2.8
Main results
System Production
Produced Energy 3880 kWh/year Specific production 970 kWh/kWp/year
Performance Ratio PR 78.06 %
Legends
GlobHor Global horizontal irradiation EArray Effective energy at the output of the array
DiffHor Horizontal diffuse irradiation E_Grid Energy injected into grid
T_Amb Ambient Temperature PR Performance Ratio
GlobInc Global incident in coll. plane
GlobEff Effective Global, corr. for IAM and shadings
PVsyst V7.2.8
VC0, Simulation date:
26/01/24 16:36
with v7.2.8
Loss diagram
1735 kWh/m² Global horizontal irradiation
PVsyst V7.2.8
VC0, Simulation date:
26/01/24 16:36
with v7.2.8
Special graphs
Diagramme d'entrée/sortie journalier