This document summarizes an alarm sounder with supplementary optical indication called the SintesoTM/ CerberusTM PRO FDS229-R and FDS229-A. It has 11 selectable tones at up to 99 dB, adjustable flashing modes and sound levels, and is powered and communicated with via FDnet/C-NET. It is intended for use on escape routes and corridors along with fire control panels. Accessories include detector bases, sealing elements, and designation plates.

Uploaded by

cemboz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
23 views8 pages

FDS229 R122

This document summarizes an alarm sounder with supplementary optical indication called the SintesoTM/ CerberusTM PRO FDS229-R and FDS229-A. It has 11 selectable tones at up to 99 dB, adjustable flashing modes and sound levels, and is powered and communicated with via FDnet/C-NET. It is intended for use on escape routes and corridors along with fire control panels. Accessories include detector bases, sealing elements, and designation plates.

Uploaded by

cemboz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 8

Sinteso™/ Cerberus™ PRO

Alarm sounder with supplementary optical indication


FDS229-R, FDS229-A

For the automatically addressed detector bus FDnet/C-NET

Alarm sounder with 11 tones to choose from, 2 programmable activation levels


Sound level up to 99 dB(A); can be set on three levels
Optical indication with set flashing sequence, adjustable flashing mode
Supply and communication via FDnet/C-NET
Compatible with addressed detector base
Option of using base accessories and sealing element
Monitoring of device status

A6V10229545_g_en_-- Building Technologies


2018-06-15 Control Products and Systems
Properties

Eco-friendly
Environmentally friendly processing
Reusable materials
Electronic parts and synthetic materials can be easily separated

Features
Protected electronics, high-quality components
Integrated line separator
Adjustable sounds and sound levels, sounds synchronized for all alarm devices
Adjustable flashing mode
Addressed base FDB221/222 with screwless connection terminals
No auxiliary supply necessary; supply takes place via FDnet/C-NET
Very low operating current
Periodic test of acoustic part (inaudible)
Monitoring of device status

Use
Along escape routes
Corridors
Staircases

Intended use
The alarm sounder FDS229 is intended for use as an alarm device on an FDnet/C-NET
detector line in conjunction with a fire control panel FC20xx ('Sinteso' product line), FC72x
('Cerberus PRO' product line), or FC361-xx ('Cerberus FIT' product line).

Functions
Acoustic alarming in the event of a fire alarm; clearly recognizable as a danger signal
Additional optical display
Synchronization of sounds with all alarm sounders and sounder bases on the same
detector line (FDnet/C-NET)
Flashing mode
– The optical indication flashes when 'Alert' or 'Evac' is activated
– The optical indication only flashes when 'Evac' is activated, not when 'Alert' is

Type Overview

Type Designation Order number Weight [kg]


FDS229-R Alarm sounder with supplementary A5Q00023093 0.130
optical indication, red
FDS229-A Alarm sounder with supplementary A5Q00023092 0.130
optical indication, orange

2
Building Technologies A6V10229545_g_en_--
Fire Safety 2018-06-15
Accessories

Type Designation Order number Weight [kg]


FDB221 Detector base, addressable A5Q00001664 0.027
FDB222 Flat, addressable detector S54319-F1-A1 0.026
base
FDBZ293 Detector locking device A5Q00005035 0.001
FDBZ295 Sealing element S54319-F10-A1 0.062
FDB291 Base attachment A5Q00001603 0.035
FDBZ291 Designation plate A5Q00002621 0.002
FDB293 Base attachment humid A5Q00003945 0.314
– M20 x 1.5 metal cable gland A5Q00004478 0.036
DBZ1193A Designation plate BPZ:4864330001 0.007
DBZ1194 Protective cage BPZ:4677110001 0.138
DBZ1190-AA Micro terminal 0.28…0.5 mm 2 BPZ:4677080001 0.001
DBZ1190-AB Connection terminal BPZ:4942340001 0.001
0.5…2.5 mm2

Addressable detector base FDB221 / FDB221-AA


Function:
Detector base with stilts for fire detectors with addressable signal processing
'Orange' connection terminals, 0.2…1.5 mm 2 conductor cross-section
FDB221-AA also contains micro terminal DBZ1190-AA
Use:
For recess-mounted cable entry
For surface-mounted cable entry up to a cable diameter of 6 mm

Flat, addressable detector base FDB222


Function:
Flat detector base for fire detectors with addressable signal processing
'Orange' connection terminals, 0.2…1.5 mm 2 conductor cross-section
Use:
For flush mounting; only for recess-mounted cable entry

Sealing element FDBZ295


Function:
For improving the protection category. However, detectors can no longer be
installed or removed using the detector exchanger.
Note: Cannot be used in conjunction with designation plate FDBZ291!

3
Building Technologies A6V10229545_g_en_--
Fire Safety 2018-06-15
Base attachment FDB291
Function:
For routing surface-mounted cables larger than Ø 6 mm
Detector base is secured with a snap fastener

Designation plate FDBZ291


For labeling with the location address
Can only be used without detector base seal FDBZ295

DBZ1190-AA micro terminal and DBZ1190-AB connection terminal


Micro terminal DBZ1190-AA
– Cable cross section up to max. 0.5 mm²
Connection terminal DBZ1190-AB
– Cable cross section up to max. 2.5 mm²
– For connecting two external alarm indicators or the cable shielding

Base attachment humid FDB293


For achieving a higher protection category
For mounting in wet or humid environments
Required when using detector heating unit FDBH291
Required when using protective cage DBZ1194 or EMC-protective cage
FDBZ294
Mounted between detector base and ceiling
Detector base mounted quickly: The detector base simply clicks into place in
base attachment humid FDB293.

Designation plate DBZ1193A


For labeling with the location address
Can only be used with base attachment wet FDB295/BA721 or base
attachment humid FDB293

Protective cage DBZ1194


To protect the alarm sounder from damage
Can only be mounted in combination with the base attachment humid FDB293
or base attachment wet FDB295/BA721

4
Building Technologies A6V10229545_g_en_--
Fire Safety 2018-06-15
Product documentation

Document ID Title
007227 Technical manual Detector exchanger and tester FDUD292
008331 List of compatibility (for 'Sinteso™' product line)
009718 Technical Manual Intelligent detector tester FDUD293
010095 Technical manual Alarm sounder with supplementary optical indication
FDS229
010096 Installation Alarm sounder beacon FDS229
A6V10208532 Installation Sealing element FDBZ295
A6V10208546 Installation Detector base FDB20x/FDB201-AA, FDB22x/FDB221-AA,
Base attachment FDB291, Detector designation plate FDBZ291,
Dummy detector FDX291
A6V10208550 Installation Base attachment humid FDB293
A6V10208552 Installation Detector locking device FDBZ293
A6V10229261 List of compatibility (for 'Cerberus™ PRO' product line)
A6V10331076 Installation Base attachment wet FDB295, Detector designation plate
DBZ1193A, Protective cage DBZ1194, EMC-protective cage FDBZ294
A6V10882301 List of compatibility (for 'FC360' product line)

Related documents such as environmental declarations, CE declarations, etc., can be


downloaded at the following Internet address:
http://siemens.com/bt/download

5
Building Technologies A6V10229545_g_en_--
Fire Safety 2018-06-15
Notes

Mounting
The alarm sounder FDS229 is inserted directly in the detector base and mounted on
walls or ceilings.
For recess-mounted feed lines
Possible for surface-mounted feed lines with a cable diameter up to 6 mm with base
FDB221; otherwise, use base attachment FDB291 or base attachment humid FDB293
For higher protection category, use sealing element FDBZ295; for recess-mounted feed
lines only

FDB221 FDB222

FDS229 FDS229

FDBZ295

FDB221

FDS229

Disposal

The device is considered an electronic device for disposal in accordance


with the European Guidelines and may not be disposed of as domestic
garbage.
Dispose of the device through channels provided for this purpose.
Comply with all local and currently applicable laws and regulations.

6
Building Technologies A6V10229545_g_en_--
Fire Safety 2018-06-15
Technical data

FDS229-R FDS229-A
Operating voltage DC 12…33 V
Operating current
Standby 250 A
Sound activated 3.5 mA
Additional optical indicator activated 3.5 mA
Sound and indication activated 7.0 mA
Sounds 11
2 activation levels
3 sound levels
Sound level 80…99 dB(A)
Number of beacon patterns 1 (intermittent)
Light intensity at DC 32 V, 1.27…3.2 cd 1.1…2.8 cd
depending on viewing angle -30°…+30°
External alarm indicator 2
Operating temperature -25…+65 °C -25…+55 °C
Storage temperature -30…+75 °C
Air humidity 95 % rel.
Communication protocol FDnet/C-NET
Connection terminals According to detector base
Color Transparent red Transparent orange
EN 60529/IEC 60529 protection category: FDS229 with
Base FDB221 or FDB222 Wall mounting with feed line
Base attachment FDB291 From below IP43, otherwise IP42
Base FDB221 and sealing element FDBZ295 IP44
Base attachment humid FDB293 IP54
Standards EN 54-3, EN 54-17
Approvals
VdS G207156 G207156
LPCB 531p/03 531p/02
DNV GL (marine) MEDB00003UV MEDB00003UV
C-NET, FDnet system compatibility FS720, FS20, FC360

Siemens Schweiz AG; Theilerstrasse 1a


07 0786 FDS229-A / FDS229-R CH-6300 Zug
Technical data: see doc. 010095
FDS229 - Sounder incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings.
305/2011/EU (CPR): EN 54-3 / EN 54-17 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581
The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is
obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download
DoP No.: 0786-CPR-20345; DoC No.: CED-FDS229

7
Building Technologies A6V10229545_g_en_--
Fire Safety 2018-06-15
Dimensional drawings

FDS229 with FDB221 FDS229 with FDB222


100 100

52.5

47.5
FDS229 with FDB221 and FDBZ295
106.8

55

Issued by © Siemens Switzerland Ltd, 2015


Siemens Switzerland Ltd Technical specifications and availability subject to change without notice.
Building Technologies Division
International Headquarters
Theilerstrasse 1a
CH-6300 Zug
Tel. +41 58 724 2424
www.siemens.com/buildingtechnologies
8
Building Technologies A6V10229545_g_en_--
Fire Safety 2018-06-15
Document ID A6V10229545_g_en_-- Manual FD20/FD720
Edition 2018-06-15 Register 6

You might also like