Lecture 10 Stream Gauging
Lecture 10 Stream Gauging
STREAM GAUGING
LECTURE 10
2
STREAM GAUGING: GENERAL
Stream flow data is primarily gathered by hydrologists for hydrologic studies of
projects. Projects may be Dams, Barrages, Irrigation, Drainage, Flood control
projects, etc.
For hydro projects, stream flow data is basic data on which other aspects of
project are dependent. Hydro data is a must for water related projects,
especially; bridges, culverts, spillways, reservoirs, food plain delineation and
flood warning systems
3
IMPORTANCE OF STREAM GAUGING
Streams provide water, that can be used for:
water supply for human settlements and animals
Irrigation water for plants
Energy/power production
Navigation in the channel
Stream flow may cause:
Floods that increase hardship and cause damage
Data gathered at a stream gauging station usually comprises of
Stage
Discharge
Sediment (to develop sedigraphs)
4
SITE SELECTION OF STREAM GAUGE
The stage gauge is installed within the influence of a CONTROL (factor influencing the
stage discharge relation)
Relationship between the stage and discharge is controlled by:
A control section (Fall, rapids, etc), or by
Reach of stream (roughness, slope, shape of section)
7
STAGE
Datum of the gauge might be a recognized datum such as North
American Vertical Datum of 1988 (NAVD 88) or SURVEY OF PAKISTAN
DATUM (SPD) or an arbitrary datum selected by a user.
Sometimes datum is taken as Mean Sea Level (MSL)
For each gauging station, maintain a permanent datum that has at least
three permanent reference marks that are independent of the gage
structure
8
STAGE MEASUREMENTS
The gauge is an instrument used for the purpose of determining
stage at a gauging site
Q H
Reliability in the discharge record, depends on the reliability of
the gauge height record
Gauge heights might be achieved by Systematic observations
of
Non-recording gauges
Recording gauges
Crest gauges
Automatic water levels and sensors 9
STREAM FLOW MEASUREMENTS
1. Direct methods (stream gauging)
(a) Area-velocity methods
(b) Dilution techniques
(c) Electromagnetic method
(d) Ultrasonic method.
2. Hydraulic Devices
Weirs and notches
Orifices
Flumes
3. Indirect Techniques
Slope-area method
Rating Curve
10
AREA VELOCITY METHODS
Q= A x V
13
Conical cups
CURRENT METER METHOD
Price Current Meter
In shallow water meter is mounted on a rod as the observer wades (Walks)
through the stream and notes down number of revolutions
14
CURRENT METER METHOD
Propeller type Current Meter
In this type a propeller rotates about a horizontal
axis
Contacting mechanism is same
Sediment may entrap in the bearing
All the measurement procedure remains the same
Contact
Chamber
Wading Rod
Propellers
Foot Plate 15
RATING OF CURRENT METER
Rating of current meter is to establish relationship between point velocity
of flow in a stream and the revolution per second of current meter
It is done on a flume 400’ x 6’ x 6’ (length x width x depth)
Electronically driven car rides on rails extending the length of the flume.
The car carries current meter at constant rate through still water in the
flume
𝑉= 400’
6’
and N are counted revolutions per second and rating curves are
developed
6’
V= (a + b) N
Where a and b are calibration constants and N number of
revolutions/sec
16
CURRENT METER METHOD
Propeller type Current Meter
17
CURRENT METER MEASUREMENT
V
Velocity
Depth
18
CURRENT METER METHOD
19
CURRENT METER MEASUREMENTS
Mean Velocity:
Is equal to average of the velocities at 2
tenths and 8 tenths depth below water,
Or
is equal to velocity at 6 tenths below the
water surface
Velocity Measurements:
Six-tenths depth (Shallow Flows)
Two point method (Deep Flows)
Three Point method (very deep flows)
20
Steps
CURRENT METER MEASUREMENTS
Divide the entire cross-section in 20-30 vertical sections (Qi <10% Q)
Measure total depth(D) at a point, by sounding with meter cable
Take meter to 0.2D depth below the water surface and start the stop watch on an
impulse and count number of revolutions and stop the stop watch at the next impulse Air Line
by current meter
V=a + b N, N is revolution per sec, and a, b are calibrating constant for the current Ѳ
meter. Water Surface
Place the current meter to 0.8D depth below the water surface and measure number
of revolutions per sec.
In shallow waters only one velocity measurement is sufficient at 0.6D depth
If velocities are higher, current meter and sounding weight will not be able to hang
vertically below the point of suspension Stream bed
Under this condition meter is higher than indicated depth
Stream having strong current
Apply Correction
Ѳ=12o Error ≈ 2 %
21
CURRENT METER MEASUREMENTS
Steps
Compute average velocity in each vertical section
𝑉 =𝑉.
. .
𝑉 = or
𝑉. + 2𝑉 . 𝑉 .
𝑉 =
4
22
23
24
25
NUMERICAL PROBLEM
Distance from Depth (ft) Meter Depth (ft) Revolutions (R) Time (sec)
bank (ft)
0 0 0 0 0
Compute the stream flow for the 2 1 0.6 10 50
measurements of data given. Take the 4 3.5 2.8 22 55
0.7 35 52
meter rating from equation with a= 0.1
6 5.2 4.2 28 53
and b=2.2 for v in ft/sec. 1 40 58
9 6.3 5 32 58
1.3 45 60
V = a + bN (ft/s)
11 4.4 3,5 28 45
a=0.1 0.9 33 46
b=2.2 13 2.2 1.3 22 50
0.5 12 49
26
NUMERICAL PROBLEM
V = a + bN (ft/s) a=0.1, b=2.2
Distance Depth Meter Revolutions Time N (Rev/Sec) V (ft/sec) Vmean Width of Area of Q= a . Vmean
from bank (ft) Depth (ft) (sec) (ft/sec) section (ft) section (ft2)
(ft)
0 0 0 0 0 0 0 0 1 0 0
17 0 0 0 0 0 0 0 1 0 0
52.55 71.51
Sum 27
NUMERICAL PROBLEM
Results:
Q= 71.51 Cfs
∑ .
Vmean = ∑
= =1.36 ft/s
.
∑ .
Hydraulic Depth= Dmean = = = 3.09 ft
28
29
DILUTION METHODS
Developed in 1863
Effective in flashy and turbulent hilly streams where current meters are difficult
to use
Also for closed conduits such as penstocks, sewer pipelines current meter is not
a measurement tool.
The method involves the injection of a chemical/ tracer into the flow and to
obtain samples of the chemical water at a section d/s where dozing
solution initially was mixed with the stream water
Basic Assumptions:
Mixing of the tracer dye with river flow which can be better achieved in turbulent streams
Chief advantage:
Precise knowledge of section geometry is not required
Disadvantage:
Expensive for measuring large streams and special equipment is required 30
DILUTION METHOD
31
DILUTION METHOD
32
DILUTION METHOD
33
DILUTION METHODS
Reach Characteristics:
No loss or gain of water in the reach
Mixing must be complete at the sampling station
Wide channels and reaches with bifurcation should be avoided
Pools of dead water zones should be avoided
A reach where turbulence is high is to be preferred, bends narrows and water falls are good
aids for mixing.
34
DILUTION METHOD FOR DISCHARGE
MEASUREMENT
Injection methods:
Sudden Injection
Constant rate of injection
Sudden Injection
In this method a known volume V of the dozing solution or tracer is added to the stream as rapidly as
possible
Sample are then taken at regular intervals of time and chemical concentration
A curve is plotted between time and concertation called as Time-concentration curve
35
DILUTION METHOD FOR DISCHARGE
MEASUREMENT
Sudden Injection
Concentration
Time
𝐴𝑟𝑒𝑎 = 𝐶 . 𝑑𝑡
36
DILUTION METHOD FOR DISCHARGE
MEASUREMENT
Sudden Injection
Assumptions
There is no loss of tracer between the injection and sampling section
Area under the curve is same at different points of the sampling cross-sections
Advantages
Minimum amount of solution is required
More economical as continuous injection is not required
Less sensitive to the position of the sampling station
Disadvantage
Sampling and analysis for this method is rigorous
37
DILUTION METHOD FOR DISCHARGE
MEASUREMENT
Constant rate of Injection
In this method dozing of the chemical/ tracer has to be continued at a constant predetermined
rate until the concentration of the chemical at the sampling point is constant at the sampling
point where mixing is inadequate
Assumptions
Amount of tracer between the injection of the sampling section is constant during the period of
sampling
Concentration of the tracer is constant in the sampling cross section
38
NUMERICAL
39
ULTRASONIC METHOD
Also known as Time-Transit method
Can provide continuous discharge measurement
Transducer
Sonic pulses are emitted from transducers on opposite banks and 45o
located on a line about 45o from the direction of the flow. One pulse
L
has a component with the stream velocity and the other is opposed
V
The difference in pulse velocity can be related to mean water velocity VP
at the level of transducers
Transducer
By using several pairs at different levels and water level indicator, the
discharge at the station can be computed
Procedure is accurate within
40
HYDRAULIC DEVICES
By construction of regular structures
Spillways, sluice gates, turbine gates
Weirs and notches
Flumes (Parshal Flume, Venturi Flume)
Highway culverts
41
WEIRS AND NOTCHES
Weirs and notches
42
Flumes
FLUMES
43
NUMERICAL
44
STAGE-DISCHARGE RELATIONS
Rating Curve
Dispersion of the measured data should be <2% (standard deviation)
Larger dispersion indicates
Control shifts more or less continuously (scour, deposition and growth of vegetation)
Water surface slope varies at the control as a result of backwater
Measurements are not carefully made
45
EXTENSION OF RATING CURVE
To interpolate the g-Q relation
No completely satisfactory method for extrapolating a rating curve beyond the
highest measured discharge
1. logarithmic method
2. A method
46
ASSIGMENT#3
Question#:1 Differentiate between:
Non-recording gauges
Recording gauges
Crest gauges
Automatic water levels and sensors
Deadline: 22nd November 2023
47
48
49