Biffi 6

The BIFFI ICON 2000 is an intelligent, multi-turn electric actuator with the following key features: 1) It has an easy set-up process that can be performed locally without removing any bolts or nuts, reducing set-up time. 2) It has an enhanced local interface with a double display showing position, torque, alarms and warnings. 3) It has built-in diagnostics that continuously monitor the system and display diagnostic messages in multiple languages without needing to decipher codes. 4) It has a modular design, high performance microchip, and reduced internal wiring for flexibility, reliability and lower maintenance costs.

Uploaded by

Goutham KS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
60 views12 pages

Biffi 6

The BIFFI ICON 2000 is an intelligent, multi-turn electric actuator with the following key features: 1) It has an easy set-up process that can be performed locally without removing any bolts or nuts, reducing set-up time. 2) It has an enhanced local interface with a double display showing position, torque, alarms and warnings. 3) It has built-in diagnostics that continuously monitor the system and display diagnostic messages in multiple languages without needing to decipher codes. 4) It has a modular design, high performance microchip, and reduced internal wiring for flexibility, reliability and lower maintenance costs.

Uploaded by

Goutham KS
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

BIFFI ICON 2000

Electric Actuator

Intelligent, non-intrusive, multi-turn electric actuator

Features
Easy set-up
The set-up and commissioning is the most
delicate part of the life of an actuator in a
plant. A good set up will prevent most of
the problems which normally arise in
actuation.
With intelligent actuators, the initial tuning
of the core parameters is performed by
way of the local interface and its software.
The procedure is accomplished even in
hazardous environments as it is not
necessary to unscrew a single bolt or nut,
which drastically reduces set-up time.
Enhanced local interface
The ICON 2000 actuator has a double
display showing updated information on
actuator status and variables value: the
upper display either indicates position or
torque; the lower (2 rows) gives extended
information on alarms, warnings, etc.
The local pushbutton gives full access to
the actuator with no need for any extra
setting tool.
Password protection for unauthorized
access is available.
Diagnostics
Internal circuits continuously monitor the
status of the system and elaborate all the
information coming from the sensors:
diagnostic messages are displayed in one
of the available languages (Italian, English,
Spanish, Portuguese, French, and
German), so there is no need to decipher
complicated codes. The set of messages is
complete both with alarms and warnings.
Cost reduction and user-friendliness
The reduced number of mechanical parts
ensures higher reliability and lower
maintenance costs.
Internal sensors Electronic card: the latest technology
The aluminum alloy highly resistant All internal sensors are contactless. The card is controlled by high performance
housing and covers, together with a lower 16 bit microchip, Hitachi, with a flash
number of joints, have increased Icon Torque sensor
The direct measure of the motor speed memory of 128Kb. This provides high
capacity to stand up to the most flexibility and the ability to reprogram if
aggressive environments. reports torque with high precision and a
resolution of 1% of the nominal torque. necessary.
A double-sealed enclosure assures All the internal wiring has been
protection from dust and humidity. The Position sensor
Controlled by a dedicated microprocessor considerably reduced.
choice of internal components has
increased the overall system efficiency (the with low power consumption, it is based on The modular design of the electronic cards
motor is directly engaged to the gears) Hall-effect incremental encoder with a allows high flexibility for a great variety of
lowering the operational cost. resolution of 10° of output shaft rotation. combinations.

A reduction of training costs is also Rotations in both senses are recognized


achieved because of the user friendly and counted.
system. If manually operated (i.e. during power
failure), the position is updated, stored and
displayed locally.

Flow Control Biffi is either a trademark or registered trademark of Tyco International Services AG or its affiliates in the
United States and/or other countries. All other brand names, product names, or trademarks belong to
their respective holders.

Total Flow Control Solutions™ Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477-US-0409
BIFFI ICON 2000
Electric Actuator

Double sealed terminal


box for high protection.
Wide enclosure to facilitate
wiring connection Heavy-duty simplified
gearing for higher efficiency High precision
internal sensors.
Low consumption
position encoder
specifically
designed for
electric actuators

Recessed buttons to
avoid unwanted operation

Easy connection for


quick motor removal
User friendly interface:
actuating your valve
has never been so easy

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


2
BIFFI ICON 2000
Electric Actuator

Features

ICON 2000 Control Package Features


Optional Base
Module Unit Features
♦ Torque/position limit switch
♦ Position display
♦ 3 push buttons (open-stop-close)
♦ 2 LED pilot lights
♦ Selector switch (local-off-remote)
♦ Remote control via dry contacts
♦ Reversing contactor
♦ Control transformer (fused primary and secondary)
♦ Local selector switch status
♦ Auto-phase correction
♦ Single phase protection
♦ Monitor relay
♦ Speed control (timer)
♦ Remote control via 24 volt thru 125 volt AC or DC signal
♦ Motor running indication
♦ Alarm light
♦ Emergency shutdown (ESD)
♦ 4-20 mA input and output
♦ 4-20 mA (output only)
♦ 4-20 mA/torque output
♦ PID (closed loop control)
♦ Fieldbus options:
LONWORKS® modbus
DEVICENET™ profibus
♦ Non-intrusive torque and position limit settings
♦ Configuration parameters are set locally or remotely
♦ High/low temperature alarm (internal)
♦ LCD display
♦ Torque display
♦ Auxiliary battery (remote position transmission)
♦ Jammed valve protection
♦ Auxiliary heater
♦ Instantaneous reversal protection (programmable from 0.4 to 4 seconds)
♦ Programmable torque/position end of travel
♦ Maximum torque alarm
♦ Electronic temperature alarm
♦ Programmable clockwise or counterclockwise valve rotation
♦ Electronic nameplate
♦ Data log (storage of main events)
♦ Alarm diagnostics
♦ Programmable in five languages

DEVICENET™ is a trademark of the Open Device Net Vendor Association


LonWorks® is a registered trademark of the Echelon Corporation.

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


3
BIFFI ICON 2000
Electric Actuator

Block and Terminals Diagram

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


4
BIFFI ICON 2000
Electric Actuator

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


5
BIFFI ICON 2000
Electric Actuator

Base Version Technical Data

Voltage ratings • Option 2 • Salt spray test


The actuator can accept the following EEx-de IIC T4 according to EN50014, ICON 2000 external coating is tested
voltage supplies: EN50019 and EN50281-1-1 for resistance to salt spray for 1,500
Class I, div.1 group B, C and D – hours according to ASTM B117/IEC
Three phase: Class II, III, div.1 groups E, F and G. 68-2-11.
• 50 Hz
230, 240, 380, 400, 415, 440, 460, IP 68 according to IEC 529 and CEI • Noise test
480, 500, 690 V EN60529 (15 m dept/90 hours), or ICON 2000 are tested according to
alternatively NEMA 4, NEMA 4X and EN21680. Noise level is less than
• 60 Hz NEMA 6 according to NEMA ICS6. 65 dB (grade A) at 1m distance.
208, 280, 380, 460, 480, 575 V
Single phase Safety Compliance Motors
• 110, 115, 220, 240 V at 50, 60 Hz • Electromagnetic compatibility ICON 2000 can be equipped with three-
directive (EMC) phase or single-phase asynchronous,
Direct Current ICON 2000 actuators conform to squirrel cage, induction-type low-inertia
• 24, 48, 110, 240 V the requirements of EMC Directive balanced motor. The open frame is
89/336/EEC and further amendments. protected by an explosion proof/
Tolerance on fluctuations
waterproof cover fixed on the actuator
• Voltage: ±10% continuous • Low voltage directive (LV)
housing. Internal protection is provided
+10% -15% intermittent ICON 2000 actuators conform with
by a temperature sensor, inserted in
Low Voltage Directive 73/23/EEC and
• Frequency: ±2% motor windings.
further amendments by the application
of EN60204-1 1993. For direct current the motor will be
Working temperature furnished with permanently magnetic
• The standard range is -22°F to 185°F • Machinery directive
stator for nominal powers up to 400 W
[-30°C to +85°C] ICON 2000 actuators comply with
at 3000 rpm, or with a wound stator for
the provision of Machinery Directive
• Extended ranges -40°F to 158°F nominal power up to 1000 W at 3000 rpm.
98/37/EEC.
[-40°C to +70°C] The motor flange is directly coupled to
• Special low range temperature version Test Summary the actuator housing with internal flying
-67°F to 158°F [-55°C to +70°C] • Life test leads wired to an intermediate terminal
Standard ICON 2000 life test is based board.
Storage temperature on AWWA 540-93 for a minimum of
• From -67°F to 185°F [-55°C to +85°C] 10,000 cycles. Cinematic reduction chain and
lubrication
• Vibration test
Environmental protections ICON 2000 are certified as per IEC
Motor power is transmitted to the output
• Only waterproof hollow shaft directly via a high torque
60068-2-6- Appendix B (plant
IP 68 according to IEC 529 and CEI capability and high efficiency worm
induced): frequencies from 1 to 500 Hz
EN60529 (15 m dept/90 hours), or shaft/worm wheel reduction without any
(in 3 axes) with 2.0g peak acceleration.
alternatively NEMA 4, NEMA 4X and interposition of spur or helical gears.
Sweep cycles in each axis: 10.
NEMA 6 according to NEMA ICS6. Output hollow shaft is with teeth
• Seismic test termination in order to transmit only a
• Standard explosion proof degree ICON 2000 are tested in accordance torque to the stem nut.
EEx-d IIB T4 according to EN50014, with IEC 60068-2-57. Frequencies
EN50018 and EN50281-1-1 Lubrication is through an oil bath with
from 1 to 35 Hz (in 3 axes) with max
Class I, div.1 group C and D – two points for filling and draining.
2.0g peak acceleration. Verification of
Class II, III, div.1 groups E, F and G. structural integrity at 5g. Endurance of
IP 68 according to IEC 529 and CEI oscillogram: 30 seconds.
EN60529 (15 m dept/90 hours), or • Environmental test
alternatively NEMA 4, NEMA 4X and ICON 2000 are tested according to the
NEMA 6 according to NEMA ICS6. following standards: IEC 68-2-1 (cold)
• Option 1 up to -67°F [-55°C], IEC 68-2-2 (dry
EEx-d IIC T4 according to EN50014, heat) up to 185°F [+85°C], IEC 68-2-3
EN50018 and EN50281-1-1 (damp heat) up to 104°F [+40°C] with
Class I, div.1 group B, C and D – 93% relative humidity.
Class II, III, div.1 groups E, F and G.
IP 68 according to IEC 529 and CEI
EN60529 (15 m dept/90 hours), or
alternatively NEMA 4, NEMA 4X and
NEMA 6 according to NEMA ICS6.

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


6
BIFFI ICON 2000
Electric Actuator

Specifications

Notes Multi-Turn Selection Chart


1. The torque data shows is for on/off service Torque Output Motor Data
only, with 1 and 3 phase asynchronous
motors.
Maximum (Ft. Lbs.)
Stem Bolt
2. Pullout torque is the maximum torque
produced by the actuator when the torque Model Acceptance Unit Circle Motor Available
switch trips at the 100 percent setting. No. Threaded Keyed RPM Pullout Run Stall (Inches) Size Voltages
3. The RPMs shown are based on the running 010/90 1.25” 2.0" 14 66 27 96 4.0 SM10 A, B, C
torque of the actuator.
4. The running torques shown are the 15-minute 010/90 1.25” 2.0" 22 66 27 96 4.0 SM11 A, B, C
continuous torques of the actuator. For 010/90 1.25” 2.0" 29 66 27 96 4.0 SM12 A, B, C
applications where the running torques
exceed these values or for stroke times that 010/90 1.25” 2.0" 43 66 27 96 4.0 SM13 A, B, C
exceed 15 minutes, consult factory. 010/90 1.25” 2.0" 58 66 27 96 4.0 SM14 A, B, C
5. Rated torques are based on +10%, -10%
010/90 1.25” 2.0" 86 66 27 96 4.0 SM15 A, B, C
percent of the rated voltage. For voltage
requirements outside this range, consult 010/90 1.25” 2.0" 173 66 27 96 4.0 SM16 A, B, C
factory.
A = 230/480 VAC, 3 ph, 60 Hz,
575 VAC, 3 ph, 60 Hz 020/180 1.75” 2.75" 14 133 53 199 5.5 SM12 A, B, C
380 or 415 VAC, 3 ph, 50 Hz
020/180 1.75” 2.75" 22 133 53 199 5.5 SM13 A, B, C
B = 120 VAC, 1 ph, 60 Hz
110 VAC, 1 ph, 50 Hz 020/180 1.75” 2.75" 29 133 53 199 5.5 SM14 A, B, C
C = 240 VAC, 1 ph, 60 Hz 020/180 1.75” 2.75" 43 133 53 199 5.5 SM15 A, B, C
220 VAC, 1 ph, 50 Hz
020/180 1.75” 2.75" 58 133 53 199 5.5 SM21 A, B, C
020/180 1.75” 2.75" 86 133 53 199 5.5 SM22 A, B, C
020/180 1.75” 2.75" 173 133 53 199 5.5 SM23 A, B, C

030/360 2.375” 2.75" 14 265 106 398 5.5 SM14 A, B, C


030/360 2.375” 2.75" 22 265 106 398 5.5 SM15 A, B, C
030/360 2.375” 2.75" 29 265 106 398 5.5 SM21 A, C
030/360 2.375” 2.75" 43 265 106 398 5.5 SM22 A, C
030/360 2.375” 2.75" 58 265 106 398 5.5 SM30 A
030/360 2.375” 2.75" 86 265 106 398 5.5 SM23 A
030/360 2.375” 2.75" 173 265 106 398 5.5 SM31 A

040/720 2.50” 3.75" 14 531 212 797 6.5 SM21 A, C


040/720 2.50” 3.75" 22 531 212 797 6.5 SM22 A, C
040/720 2.50” 3.75" 29 531 212 797 6.5 SM30 A
040/720 2.50” 3.75" 43 531 212 797 6.5 SM40 A
040/720 2.50” 3.75" 58 531 212 797 6.5 SM41 A
040/720 2.50” 3.75" 86 531 212 797 6.5 SM31 A
040/720 2.50” 3.75" 173 531 212 797 6.5 SM42 A

050/1440 3.0” 4.5" 14 1,062 425 1,593 10.0 SM30 A


050/1440 3.0” 4.5" 22 1,062 425 1,593 10.0 SM40 A
050/1440 3.0” 4.5" 29 1,062 425 1593 10.0 SM41 A
050/1440 3.0” 4.5" 43 1,062 425 1,593 10.0 SM31 A
050/1440 3.0” 4.5" 58 1,062 425 1,593 10.0 SM50 A
050/1440 3.0” 4.5" 86 1,062 425 1,593 10.0 SM42 A
050/1440 3.0” 4.5" 173 1,062 425 1,593 10.0 SM51 A

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


7
BIFFI ICON 2000
Electric Actuator

Motor Data Chart

575 VAC 3 Phase Notes


Motor 575 VAC 3 Phase 1. Three Phase Supply 575V/60Hz; tolerances
on Voltage value - 10%/+10%.
Model Size KW RPM FLA IMAX LR
2. Nominal Output Power (KW) according to
ICON-010/90-14 SM10 0.085 585 1.13 1.25 1.67 CEI 2-3 (Eq. To IEC 34-1). Multiply by 1.34
ICON-010/90-22 SM11 0.128 878 1.00 1.17 2.17 to obtain horsepower.
3. FLA is the nominal current of the motor
ICON-010/90-29 SM12 0.147 585 1.84 2.00 2.92 according to IEC-34. This equals 40% of
ICON-010/90-43 SM13 0.220 878 1.34 1.67 3.67 the rated torque of the actuator.
ICON-010/90-58 SM14 0.343 1170 1.25 1.59 4.51 4. “I” MAX is the current which corresponds to
the maximum rated torque of the actuator.
ICON-010/90-86 SM15 0.441 1756 1.42 2.09 7.18
5. LR is the locked rotor current.
ICON-010/90-173 SM16 0.882 3511 1.75 3.67 11.69 6. Motors are rated for 60 starts max per hour
at 40% run with Class H motor insulation.

ICON-020/180-14 SM12 0.147 585 1.84 2.00 2.00


ICON-020/180-22 SM13 0.220 878 1.34 1.67 1.67
ICON-020/180-29 SM14 0.343 1170 1.25 1.59 1.59
ICON-020/180-43 SM15 0.441 1756 1.42 2.09 2.09
ICON-020/180-58 SM21 0.631 1170 2.67 3.34 3.34
ICON-020/180-86 SM22 0.946 1756 2.34 3.76 3.76
ICON-020/180-173 SM23 1.764 3511 3.34 6.26 6.26

ICON-030/360-14 SM14 0.343 1170 1.25 1.59 1.59


ICON-030/360-22 SM15 0.441 1756 1.42 2.09 2.09
ICON-030/360-29 SM21 0.631 1170 2.67 3.34 3.34
ICON-030/360-43 SM22 0.946 1756 2.34 3.76 3.76
ICON-030/360-58 SM30 1.347 1170 4.51 10.02 10.02
ICON-030/360-86 SM23 1.764 3511 3.34 6.26 6.26
ICON-030/360-173 SM31 4.042 3511 7.35 14.61 14.61

ICON-040/720-14 SM21 0.631 1170 2.67 3.34 3.34


ICON-040/720-22 SM22 0.946 1756 2.34 3.76 3.76
ICON-040/720-29 SM30 1.347 1170 4.51 10.02 10.02
ICON-040/720-43 SM40 2.021 1756 3.59 5.43 5.43
ICON-040/720-58 SM41 2.327 1170 6.43 10.85 10.85
ICON-040/720-86 SM31 4.042 3511 7.35 14.61 14.61
ICON-040/720-173 SM42 6.982 3511 12.10 25.04 25.04

ICON-050/1440-14 SM30 1.347 1170 4.51 10.02 10.02


ICON-050/1440-22 SM40 2.021 1756 3.59 5.43 5.43
ICON-050/1440-29 SM41 2.327 1170 6.43 10.85 10.85
ICON-050/1440-43 SM31 4.042 3511 7.35 14.61 14.61
ICON-050/1440-58 SM50 4.655 1170 10.02 17.11 17.11
ICON-050/1440-86 SM42 6.982 3511 12.10 25.04 25.04
ICON-050/1440-173 SM51 13.964 3511 25.04 50.09 50.09

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


8
BIFFI ICON 2000
Electric Actuator

Motor Data Chart

Notes 480 VAC 3 Phase


1. Three Phase Supply 480V/60Hz; Motor 480 VAC 3 Phase
tolerances on Voltage value - 10%/+10%.
Model Size KW RPM FLA IMAX LR
2. Nominal Output Power (KW) according to
CEI 2-3 (Eq. To IEC 34-1). Multiply by 1.34 ICON-010/90-14 SM10 0.085 585 1.35 1.50 2.00
to obtain horsepower.
ICON-010/90-22 SM11 0.128 878 1.20 1.40 2.60
3. FLA is the nominal current of the motor
according to IEC-34. This equals 40% of ICON-010/90-29 SM12 0.147 585 2.20 2.40 3.50
the rated torque of the actuator. ICON-010/90-43 SM13 0.220 878 1.60 2.00 4.40
4. “I” MAX is the current which corresponds to
the maximum rated torque of the actuator. ICON-010/90-58 SM14 0.343 1170 1.50 1.90 5.40
5. LR is the locked rotor current. ICON-010/90-86 SM15 0.441 1756 1.70 2.50 8.60
6. Motors are rated for 60 starts max per hour ICON-010/90-173 SM16 0.882 3511 2.10 4.40 14.00
at 40% run with Class H motor insulation.

ICON-020/180-14 SM12 0.147 585 2.20 2.40 3.50


ICON-020/180-22 SM13 0.220 878 1.60 2.00 4.40
ICON-020/180-29 SM14 0.343 1170 1.50 1.90 5.40
ICON-020/180-43 SM15 0.441 1756 1.70 2.50 8.60
ICON-020/180-58 SM21 0.631 1170 3.20 4.00 11.00
ICON-020/180-86 SM22 0.946 1756 2.80 4.50 14.50
ICON-020/180-173 SM23 1.764 3511 4.00 7.50 24.00

ICON-030/360-14 SM14 0.343 1170 1.50 1.90 5.40


ICON-030/360-22 SM15 0.441 1756 1.70 2.50 8.60
ICON-030/360-29 SM21 0.631 1170 3.20 4.00 11.00
ICON-030/360-43 SM22 0.946 1756 2.80 4.50 14.50
ICON-030/360-58 SM30 1.347 1170 5.40 12.00 19.00
ICON-030/360-86 SM23 1.764 3511 4.00 7.50 24.00
ICON-030/360-173 SM31 4.042 3511 8.80 17.50 52.00

ICON-040/720-14 SM21 0.631 1170 3.20 4.00 11.00


ICON-040/720-22 SM22 0.946 1756 2.80 4.50 14.50
ICON-040/720-29 SM30 1.347 1170 5.40 12.00 19.00
ICON-040/720-43 SM40 2.021 1756 4.30 6.50 30.00
ICON-040/720-58 SM41 2.327 1170 7.70 13.00 26.00
ICON-040/720-86 SM31 4.042 3511 8.80 17.50 52.00
ICON-040/720-173 SM42 6.982 3511 14.50 30.00 88.00

ICON-050/1440-14 SM30 1.347 1170 5.40 12.00 19.00


ICON-050/1440-22 SM40 2.021 1756 4.30 6.50 30.00
ICON-050/1440-29 SM41 2.327 1170 7.70 13.00 26.00
ICON-050/1440-43 SM31 4.042 3511 8.80 17.50 52.00
ICON-050/1440-58 SM50 4.655 1170 12.00 20.50 84.00
ICON-050/1440-86 SM42 6.982 3511 14.50 30.00 88.00
ICON-050/1440-173 SM51 13.964 3511 30.00 60.00 138.00

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


9
BIFFI ICON 2000
Electric Actuator

Dimensions, inches

∅C A

a1 a2

b
a

b1
h3
h2
h1

B
ISO 5210 “F” size

b2
Weight
Model A a1 a2 B b1 b2 ØC F H h1 h2 h3
lbs
ICON-010 19.09 12.80 6.30 22.64 10.83 11.81 11.81 F10 13.78 5.39 5.78 8.07 71
ICON-020 19.49 13.19 6.30 23.03 11.22 11.81 19.70 F14 14.76 6.22 6.22 9.33 79
ICON-030 23.03 16.73 6.30 24.72 12.20 12.51 23.62 F14 15.94 7.28 6.81 10.03 101
ICON-040 24.61 17.52 7.09 25.08 12.48 12.60 28.35 F16 17.72 7.68 7.60 11.61 123
ICON-050 25.98 18.90 7.09 28.86 14.29 14.57 33.86 F25 21.26 8.98 8.78 13.38 161

Note
Conduit Connections: a = (2) AT 1” diameter
b = (1) AT 11/2” diameter

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


10
BIFFI ICON 2000
Electric Actuator

Couplings - Type A

Notes to couplings type A


Ø d6 = Max threaded stem acceptance
Ø dx = The maximum accepted diameter
described by the key.
Fnom = The max thrust applicable to the ICON
2000 block type “A” in dynamic
conditions with torque control set at
100%.
Fmax = The max thrust applicable to the ICON
2000 block type “A” in static conditions
with manual override or with motor in
stall torque.

Model 010 020 030 040 050


ISO 5210 F10 F14 F14 F16 F25
Fnom (KN) 40 100 150 180 300
Fmax (KN) 60 150 225 270 450
Ø d1 4.92 6.89 6.89 8.27 11.81
Ø d2 f8 2.76 3.94 3.94 5.12 7.87
Ø d3 4.02 5.51 5.51 6.50 10
Ø d4 M10 M16 M16 M20 M16
Ø d5 1.30 1.81 2.44 2.68 3.07
Ø d6 max 1.26 1.77 2.38 2.56 2.95
Ø dx max 1.26 1.77 2.38 2.56 2.95
l1 1.57 2.17 2.76 2.95 3.74
l2 2 2.68 3.31 3.70 4.72
h1 0.12 0.16 0.16 0.20 0.20
h2 0.59 0.94 0.94 1.18 0.94
N 0.16 0.16 0.16 0.16 0.31
Weight (N) 15 75 75 150 275

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


11
BIFFI ICON 2000
Electric Actuator

Couplings - Type B1/B2

Notes to couplings type B1/B2 Model 010 020 030 040 050
Ø d7 = with standard keyway according to ISO 5210 F10 F14 F14 F16 F25
ISO 773.
Ø d5 1.30 1.81 2.44 2.68 3.07
Ø dx = The maximum accepted diameter
described by the key. B1Ø d7 H9 1.65 2.36 2.36 3.15 3.94
B2Ø d7 max 1.65 2.36 2.36 3.15 3.94
Ø dx max 1.97 2.80 2.80 3.70 4.57
l3 1.77 2.56 2.56 3.15 4.33
I4 2.20 3.07 3.11 3.90 5.31
Weight (N) 15 65 70 140 260

Couplings - Type B3/B4

Notes to couplings type B3/B4 Model 010 020 030 040 050
Ø d10 = with standard keyway according to ISO 5210 F10 F14 F14 F16 F25
ISO 773.
B3Ø d10 H9 0.79 1.18 1.18 1.57 1.96
Ø dx = The maximum accepted diameter
described by the key. B4Ø dy max 0.87 1.25 1.81 1.96 2.28
Ø dx 1.02 1.57 2.16 2.36 2.67
I6 1.96 2.76 2.76 3.94 4.72
Weight (N) 10 55 60 120 200

Tyco Valves & Controls


www.tycovalves.com

Tyco Flow Control (TFC) provides the information herein in good faith but makes no representation as to its comprehensiveness or accuracy. This data sheet is intended only as a guide to TFC products and services.
Individuals using this data sheet must exercise their independent judgment in evaluating product selection and determining product appropriateness for their particular purpose and system requirements. TFC MAKES
NO REPRESENTATIONS OR WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WITH
RESPECT TO THE INFORMATION SET FORTH HEREIN OR THE PRODUCT(S) TO WHICH THE INFORMATION REFERS. ACCORDINGLY, TFC WILL NOT BE RESPONSIBLE FOR DAMAGES (OF ANY KIND OR
NATURE, INCLUDING INCIDENTAL, INDIRECT, OR CONSEQUENTIAL DAMAGES) RESULTING FROM THE USE OF OR RELIANCE UPON THIS INFORMATION. Patents and Patents Pending in the U.S. and
foreign countries. Tyco reserves the right to change product designs and specifications without notice.

Copyright © 2004 Tyco Flow Control. All rights reserved. BIFMC-0477


12

You might also like