Instruction Manual - Series 200 Ejector Retrofit - Valve Seat Ejector To O-Ring Ejector

This document provides instructions for retrofitting a valve seat ejector to an o-ring ejector. It describes removing the existing ejector top body and related components and replacing them with a new top body and diaphragm bolt assembly from a retrofit kit. The instructions specify the part numbers for retrofit kits for different applications and chemicals. Installers are warned to follow the instructions carefully to avoid hazards from equipment rupture.

Uploaded by

Franco Arellano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views4 pages

Instruction Manual - Series 200 Ejector Retrofit - Valve Seat Ejector To O-Ring Ejector

This document provides instructions for retrofitting a valve seat ejector to an o-ring ejector. It describes removing the existing ejector top body and related components and replacing them with a new top body and diaphragm bolt assembly from a retrofit kit. The instructions specify the part numbers for retrofit kits for different applications and chemicals. Installers are warned to follow the instructions carefully to avoid hazards from equipment rupture.

Uploaded by

Franco Arellano
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Instruction Manual —

Series 200 Ejector Retrofit -


Valve Seat Ejector to O-Ring Ejector

-1- 122.6020.5
These instructions describe the installation, operation and maintenance of the subject equipment. Failure to strictly
follow these instructions can lead to an equipment rupture that may cause significant property damage, severe
per-sonal injury and even death. If you do not understand these instructions, please call De Nora Water
Technologies for clarification before commencing any work at +1 215-997-4000 and ask for a Field Service Manager.
De Nora Water Technologies, Inc. reserves the rights to make engineering refinements that may not be described
herein. It is the responsibility of the installer to contact De Nora Water Technologies, Inc. for information that
cannot be answered specifically by these instructions.

Any customer request to alter or reduce the design safeguards incorporated into De Nora Water Technologies
equipment is conditioned on the customer absolving De Nora Water Technologies from any consequences of
such a decision.

De Nora Water Technologies has developed the recommended installation, operating and maintenance procedures
with careful attention to safety. In addition to instruction/operating manuals, all instructions given on labels or
attached tags should be followed. Regardless of these efforts, it is not possible to eliminate all hazards from the
equipment or foresee every possible hazard that may occur. It is the responsibility of the installer to ensure that the
recommended installation instructions are followed. It is the responsibility of the user to ensure that the
recommended operating and maintenance instructions are followed. De Nora Water Technologies, Inc. cannot be
responsible deviations from the recommended instructions that may result in a hazardous or unsafe condition.

De Nora Water Technologies, Inc. cannot be responsible for the overall system design of which our equipment may
be an integral part of or any unauthorized modifications to the equipment made by any party other that De Nora
Water Technologies, Inc.

De Nora Water Technologies, Inc. takes all reasonable precautions in packaging the equipment to prevent shipping
damage. Carefully inspect each item and report damages immediately to the shipping agent involved for
equipment shipped “F.O.B. Colmar” or to De Nora Water Technologies for equipment shipped “F.O.B Jobsite”. Do
not install damaged equipment.

De Nora Water Technologies, COLMAR OPERATIONS


COLMAR, PENNSYLVANIA, USA
IS ISO 9001: 2008 CERTIFIED

122.6020.5 -2-
For installations where you want to change the design of your current valve seat ejector to the new design o-
ring ejector, De Nora Water Technologies offers an ejector retrofit kit.

Order from De Nora Water Technologies the correct ejector retrofit kit from the following:
(The kits are the same for 100 and 250 PPD [2 and 5 kg/h).

Part Number
Back Pressure
Chlorine Sulfur Dioxide
low BM-6639 BM-6640
high BM-6641 BM-6642

The following are the instructions on how to install this kit.


A. Remove the four (4) screws holding the ejector top body to the ejector bottom body, retain the nuts.
B. Remove the vacuum tubing connector from the top body and retain.
C. Discard the ejector top body (with valve seat and screw), screws, and diaphragm bolt assembly. Be careful to
retain the spring.
D. Wrap the threads of the vacuum tubing connector with teflon tape and screw into the new ejector top
body.
E. Re-assemble the ejector utilizing the new top body, diaphragm bolt assembly and screws. Reference Figure 1 or
2 depending on capacity of ejector.

Figure 1 - 100 PPD (2 kg/h)

-3- 122.6020.5
Figure 2 - 250 PPD (5kg/h)

Design improvements may be made without notice.


Represented by:

De Nora Water Technologies


3000 Advance Lane Colmar, PA 18915
ph +1 215 997 4000 • fax +1 215 997 4062
web: www.denora.com
mail: [email protected]